This document contains a cooling load estimation sheet that calculates the sensible and latent heat loads for rooms in a building over time. It accounts for solar and transmission gains through structures, solar gains through glass, internal heat gains from lighting, equipment, and people, and infiltration. For each time period, it sums the heat gains and calculates the sensible heat load, latent heat load, total heat gain, required supply air volume and cooling capacity.
This document contains a cooling load estimation sheet that calculates the sensible and latent heat loads for rooms in a building over time. It accounts for solar and transmission gains through structures, solar gains through glass, internal heat gains from lighting, equipment, and people, and infiltration. For each time period, it sums the heat gains and calculates the sensible heat load, latent heat load, total heat gain, required supply air volume and cooling capacity.
Droits d'auteur :
Attribution Non-Commercial (BY-NC)
Formats disponibles
Téléchargez comme XLS, PDF, TXT ou lisez en ligne sur Scribd
This document contains a cooling load estimation sheet that calculates the sensible and latent heat loads for rooms in a building over time. It accounts for solar and transmission gains through structures, solar gains through glass, internal heat gains from lighting, equipment, and people, and infiltration. For each time period, it sums the heat gains and calculates the sensible heat load, latent heat load, total heat gain, required supply air volume and cooling capacity.
Droits d'auteur :
Attribution Non-Commercial (BY-NC)
Formats disponibles
Téléchargez comme XLS, PDF, TXT ou lisez en ligne sur Scribd
NAME AREA VOL. SENSIBLE HEAT LOAD 1. SOLAR AND TRANS. GAIN THROUGH STRUCTURE TIME 10:00 TIME DIREC. Wx H AREA K E.T.D. HEAT LOAD E.T.D. mx m m² Kcal/hm²°C °C Kcal/h °C WALL x . x . x . x . GLASS x . x . x . x . PARTITION x . x . FLOOR x . x . CEILING x . ROOF x . x . SUB TOTAL (1) 2. SOLAR GAIN THROUGH GLASS F Igr Igr GLASS .x . . .x . . .x . . .x . . SUB TOTAL (2) 3. INTERNAL HEAT GAIN LIGHTING INCANDE. Kw x 860 FLUORE. Kw x 1,000 20 w / m² x m²x 1.0 EQUIP' KW x 0.5 EQUIP' & LIGHTING
PEOPLE person x 50 Kcal/h.p
p/m² x Kcal/h.p INFILTRATION
SUB TOTAL (3)
SENSIBLE LOAD TOTAL (1+2+3) 4. LATENT HEAT GAIN PEOPLE person x 60 Kcal/h.p p/m² x Kcal/h.p . INFILTRATION
SUB TOTAL (4)
5. GRAND TOTAL OF HEAT GAIN 6. SENSIBLE HEAT FACTOR . 7. SUPPLY AIR VOL. dT = °C 8. OA LOAD di= x m³/h 9. AIR-COND. CAPACITYT REQUIRED 10. SAFETY FACTOR 10 % 11. COOLING LOAD PER AREA (kcal/h.m²) DATE : A x H = V m³ SYSTEM