Vous êtes sur la page 1sur 93

Siemens AG 2007

Explosion-proof motors

4/2
4/2
4/3
4/3
4/3
4/5
4/7

Orientation
Overview
Benefits
Application
Technical specifications
Selection and ordering data
More information

4/12

Self-ventilated motors in Zones 1


with type of protection e
Aluminum series 1MA7
Selection and ordering data

4/12
4/16

4/16
4/28

4/28
4/36

4/36
4/40

4/40
4/48

4/48

Self-ventilated motors in Zones 1


with type of protection e
Cast-iron series 1MA6
Selection and ordering data
Self-ventilated motors in Zones 1
with type of protection d
Cast-iron series 1MJ6 and 1MJ7
Selection and ordering data
Self-ventilated motors in Zones 1
with type of protection d
Steel/cast-iron series
1MJ8 and 1MJ1
Selection and ordering data
Self-ventilated motors in Zones 2,
21, 22 with type of protection n
or protection against dust
explosions
Aluminum series 1LA7 and 1LA5
Selection and ordering data
Self-ventilated motors in Zones 2,
21, 22 with type of protection n
or protection against dust
explosions
Aluminum series 1LA9
Selection and ordering data

4/60

4/60
4/68

4/68
4/78

4/78
4/78

Self-ventilated motors in Zones 2,


21, 22 with type of protection n
or protection against dust
explosions
Cast-iron series 1LA6 and 1LG4
Selection and ordering data
Self-ventilated motors in Zones 2,
21, 22 with type of protection n
or protection against dust
explosions
Cast-iron series 1LG6
Selection and ordering data
Self-ventilated motors in Zones 2,
22 with type of protection n
or protection against dust
explosions
Cast-iron series 1LA8
Selection and ordering data

4/78

Forced-air cooled motors in Zones 2,


22 with type of protection n
or protection against dust
explosions
Cast-iron series 1PQ8
Selection and ordering data

4/79
4/79
4/81
4/81
4/88
4/91

Special versions
Overview
Selection and ordering data
Voltages
Types of construction
Options

4/119
4/119
4/120

Accessories and spare parts


Overview
More information

4/121
4/121
4/123
4/124

Dimensions
Overview
More information
Dimensional drawings

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Aluminum series 1MA7

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3

0.18
0.25
0.37
0.55
0.75
1.1
1.3
1.85
2.5
3.3
4.6
5.5
7.5
10
12.5

0.18
0.25
0.37
0.55
0.75
1.1
1.3
1.85
2.5
3.3
4.6
5.5
7.5
10
12.5

Rated output
at
50 Hz
60 Hz

Prated

Prated

kW

kW

T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T3
T3
T3
T3

63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 S
160 M
160 M
160 L

2810
2800
2825
2785
2845
2855
2850
2860
2865
2875
2920
2925
2945
2940
2940

0.61
0.85
1.3
1.9
2.5
3.7
4.4
6.2
8.3
11
15
18
24
33
41

66
68
73
72
73
79
78
81
82
84
83
86
87.5
88.5
89

Temperature class

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated

Trated

rated

rpm

Nm

0.74
0.81
0.8
0.80
0.85
0.85
0.88
0.88
0.87
0.89
0.9
0.92
0.9
0.92
0.93

0.55
0.7
0.93
1.4
1.81
2.5
2.9
3.95
5.3
6.7
9.2
10.6
14.3
18.6
23

1MA7 060-2BA
1MA7 063-2BA
1MA7 070-2BA
1MA7 073-2BA
1MA7 080-2BA
1MA7 083-2BA
1MA7 090-2BA
1MA7 096-2BA
1MA7 106-2BA
1MA7 113-2BB
1MA7 130-2BB
1MA7 131-2BB
1MA7 163-2BB
1MA7 164-2BB
1MA7 166-2BB

3.9
4.5
5.4
7
8.6
10.3
13.3
16.1
21
27
53
44
67
72
82

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

cos rated

Irated

Weight
IM B3
type of
construction
approx.
m

kg

1)
1)
1)
1)

Price

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)
6.5
9.5
13
16

6.5
9.5
13
16

T1,T2
T1,T2
T1,T2
T1,T2

132 S
160 M
160 M
160 L

2900
2920
2910
2910

21
31
43
53

85
87
87.5
87

0.93
0.91
0.92
0.93

12.5
18.1
24.5
30

1)

1MA7 131-2BB
1MA7 163-2BB
1MA7 164-2BB
1MA7 166-2BB

44
67
72
82

1)
1) 2)
1) 2)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY 500 V
For delta connection, overload protection with
phase-failure protection must be provided.
1

1MA7 06 . - . . .
1MA7 07 . - . . .
1MA7 08 . - . . .
1MA7 09 . - . . .
1MA7 10 . - . . .
1MA7 11 . - . . .
1MA7 13 . - . . .
1MA7 16 . - . . .

Final position:
Type of construction code
Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM V6 3)
IM V3 3) with protective
cover 3) 4)
0
1
4

IM B35

With standard flange With special


flange
IM B14, IM B34
IM B14
IM V19 3)
IM V19 3)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/13.

4/12

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Aluminum series 1MA7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown torque Torque
torque
current
class
with direct starting as multiple of rated
torque
current
torque

Moment
of inertia

TLR/Trated

J
kgm

ILR/Irated

TB/Trated

CL

Noise at rated output

tE time

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

for
temperature class
T1/T2
tE
s

for
temperature class
T3
tE
s

60
60
63
63
67
67
72
72
74
75
80
80
82
82
82

30
19
28
18
13
12
12
9
9
10
15
15
29
23
21

27
16
25
13
11
10
11
8
8
9
13
13
18
12
9

tE time
for
temperature class
T1/T2

tE time
for
temperature class
T3

tE
s

tE
s

12
24
16
15

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA7 060-2BA
1MA7 063-2BA
1MA7 070-2BA
1MA7 073-2BA
1MA7 080-2BA
1MA7 083-2BA
1MA7 090-2BA
1MA7 096-2BA
1MA7 106-2BA
1MA7 113-2BB
1MA7 130-2BB
1MA7 131-2BB
1MA7 163-2BB
1MA7 164-2BB
1MA7 166-2BB

2.3
2.2
2.3
3
2.5
2.8
2.6
2.8
2.6
2.1
1.9
2.2
2.2
2.1
2.3

Order No.

4.4
4.4
5.6
5.2
6.2
6.4
6.2
7.2
7.4
6.6
6.8
7.7
7.6
7.6
7.6

16
16
16
16
16
16
16
16
16
13
13
13
13
13
13

0.00018
0.00023
0.00035
0.00045
0.00085
0.0011
0.0015
0.002
0.0038
0.0055
0.016
0.021
0.034
0.04
0.052

49
49
52
52
56
56
60
60
62
63
68
68
70
70
70

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque
class

Moment
of inertia

Noise at rated output

TLR/Trated

CL

ILR/Irated

2.3
2.3
2.1
2.6
2.7
3
2.8
2.8
2.8
2.3
2.5
2.7
3.1
2.9
3

TB/Trated

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)
1MA7 131-2BB
1MA7 163-2BB
1MA7 164-2BB
1MA7 166-2BB

1.9
1.7
1.6
1.8

6.5
6
5.8
5.8

2.3
2.4
2.2
2.3

1)

For the following versions T3-output is stamped as standard:


order code A11/A12
voltage code 9
Alternative: order code C30 T1/T2-output on the rating plate

2)

Utilization according to temperature class 155 (F).

13
13
13
13

0.021
0.034
0.04
0.052

68
70
70
70

80
82
82
82

3)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

4)

The Second shaft extension option, order code K16 is not possible.

Siemens D 81.1 2007

4/13

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Aluminum series 1MA7

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque at
at 50 Hz
at 50 Hz
50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ...420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3

0.12
0.18
0.25
0.37
0.55
0.75
1
1.35
2
2.5
3.6
5
6.8
10
13.5

0.12
0.18
0.25
0.37
0.55
0.75
1
1.35
2
2.5
3.6
5
6.8
10
13.5

T1,T2,T3
T1,T2,T3
T1,T2,T3
T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3

63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 L

1375
1330
1310
1355
1390
1395
1420
1415
1420
1415
1435
1445
1465
1455
1465

0.83
1.3
1.8
2.6
3.8
5.1
6.7
9.1
14
17
24
33
44
66
88

55
57
60
67
73
73
77
78
80
81
85
86
87
88
89

0.66
0.75
0.77
0.74
0.73
0.75
0.78
0.82
0.82
0.83
0.83
0.82
0.82
0.87
0.84

0.52
0.62
0.8
1.1
1.59
2.05
2.5
3.1
4.5
5.5
7.5
10.4
14
19.7
27

3.9
4.5
6
6.4
8.4
11
12.7
16
20
23
29
42
61
67
107

1MA7 060-4BB
1MA7 063-4BB
1MA7 070-4BB
1MA7 073-4BB
1MA7 080-4BA
1MA7 083-4BA
1MA7 090-4BA
1MA7 096-4BA
1MA7 106-4BA
1MA7 107-4BA
1MA7 113-4BA
1MA7 130-4BA
1MA7 133-4BA
1MA7 163-4BB
1MA7 166-4BB

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
0.25
0.37
0.55
0.65
0.95
1.3
1.9
2.6
3.5
4.8
6.6
9.7

0.25
0.37
0.55
0.65
0.95
1.3
1.9
2.6
3.5
4.8
6.6
9.7

T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3

71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L

850
920
930
915
915
935
940
945
955
950
960
965

2.8
3.6
5.6
6.8
9.9
13
19
26
35
48
65
96

63
68
69
70
72
77
79
79
81
83
85
88

0.72
0.7
0.67
0.75
0.75
0.73
0.76
0.75
0.72
0.76
0.75
0.76

0.81
1.14
1.75
1.8
2.6
3.35
4.7
6.5
9
11.4
14.9
21

6.7
8.3
12.5
14
15.7
20
24
36
41
50
70
105

1MA7 073-6BA
1MA7 080-6BA
1MA7 083-6BA
1MA7 090-6BA
1MA7 096-6BA
1MA7 106-6BA
1MA7 113-6BB
1MA7 130-6BB
1MA7 133-6BB
1MA7 134-6BB
1MA7 163-6BB
1MA7 166-6BB

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY 500 V
For delta connection, overload protection with
phase-failure protection must be provided.
1

1MA7 06 . - . . .
1MA7 07 . - . . .
1MA7 08 . - . . .
1MA7 09 . - . . .
1MA7 10 . - . . .
1MA7 11 . - . . .
1MA7 13 . - . . .
1MA7 16 . - . . .

3
3)

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 1)
IM V3 1) with protective
cover 1) 2)
0
1
4
6

With standard flange With special


flange
IM B14, IM B34
IM B14
IM V19 1)
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/15.

4/14

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Aluminum series 1MA7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque
class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment
of inertia

J
kgm

Noise at rated output

tE time

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

for
temperature class
T1/T2
tE
s

for
temperature class
T3
tE
s

53
53
55
55
58
58
60
60
65
65
65
74
74
78
78

35
30
50
35
24
19
16
15
13
12
10
10
11
17
18

30
25
40
29
21
16
14
13
11
10
9
9
9
10
9

50
51
51
55
55
59
64
75
75
75
78
78

130
60
30
35
22
26
19
21
16
13
18
15

70
55
27
30
19
26
16
18
13
11
9
8

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA7 060-4BB
1MA7 063-4BB
1MA7 070-4BB
1MA7 073-4BB
1MA7 080-4BA
1MA7 083-4BA
1MA7 090-4BA
1MA7 096-4BA
1MA7 106-4BA
1MA7 107-4BA
1MA7 113-4BA
1MA7 130-4BA
1MA7 133-4BA
1MA7 163-4BB
1MA7 166-4BB

1.9
1.9
1.9
1.9
2.4
2.6
2.2
2.3
2.5
2.6
2.6
2.7
3
2.3
2.4

2.6
2.7
3.1
3.7
4.6
4.8
5.4
5.9
6.4
6.4
7.2
6.6
7.7
6.5
6.9

1.9
1.9
1.9
2.1
2.5
2.6
2.5
2.5
2.7
2.7
2.9
3.2
3.6
2.7
3

13
13
13
13
16
16
16
16
16
16
16
16
16
13
13

0.0003
0.0004
0.0006
0.00083
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.011
0.021
0.027
0.052
0.057

42
42
44
44
47
47
48
48
53
53
53
62
62
66
66

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA7 073-6BA
1MA7 080-6BA
1MA7 083-6BA
1MA7 090-6BA
1MA7 096-6BA
1MA7 106-6BA
1MA7 113-6BB
1MA7 130-6BB
1MA7 133-6BB
1MA7 134-6BB
1MA7 163-6BB
1MA7 166-6BB

2.2
2.3
2.4
2.3
2.3
2.4
2.3
1.8
2.3
2.4
2.7
2.8

3
3.6
4
3.9
4.1
4.8
5
4.4
5.1
5.6
6.4
7.7

2.1
2.4
2.4
2.4
2.4
2.5
2.5
2.4
2.8
2.8
3.1
2.2

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

2)

The Second shaft extension option, order code K16 is not possible.

3)

For motors 1MA7 06.-4. (motor series 1MA7 frame size 63, 4-pole) not
possible.

16
16
16
16
16
16
13
13
13
13
13
13

0.0009
0.0015
0.0025
0.0028
0.0038
0.0063
0.011
0.015
0.019
0.025
0.041
0.055

39
40
40
43
43
47
52
63
63
63
66
66

Siemens D 81.1 2007

4/15

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3

2.5
3.3
4.6
5.5
7.5
10
12.5
15
20
24
28
38
36
47
47
64
58
76
68
95
80
112
100
135
125
165

2.5
3.3
4.6
5.5
7.5
10
12.5
15
20
24
28
38
36
47
47
64
58
76
68
95
80
112
100
135
125
165

T1,T2,T3
T1,T2,T3
T1,T2,T3
T3
T3
T3
T3
T3
T3
T3
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2
T3
T1,T2

100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L
225 M
225 M
250 M
250 M
280 S
280 S
280 M
280 M
315 S
315 S
315 M
315 M
315 L
315 L
315 L
315 L

2865
2875
2920
2925
2945
2940
2940
2955
2950
2965
2970
2970
2975
2975
2983
2980
2982
2978
2985
2985
2985
2985
2984
2984
2985
2986

8.3
11
15
18
24
33
41
49
64
77
90
122
116
151
150
205
186
244
218
304
256
358
320
432
400
528

82
84
83
86
87.5
88.5
89
92
91.2
92
93.6
93.9
93.5
93.9
94.5
94.3
94.7
94.8
94
94.6
94.8
94.8
94.9
95.2
95.5
95.7

0.87
0.89
0.9
0.92
0.9
0.92
0.93
0.87
0.87
0.87
0.9
0.89
0.91
0.9
0.9
0.89
0.91
0.9
0.91
0.9
0.91
0.91
0.92
0.91
0.91
0.91

5.3
6.7
9.3
10.7
15.3
19.1
23
29
49
46
51
69 2)
64
85
84
115
104
134
120
169
142
198 2)
174
234
214
280

1MA6 106-2BA
1MA6 113-2BB
1MA6 130-2BB
1MA6 131-2BB
1MA6 163-2BB
1MA6 164-2BB
1MA6 166-2BB
1MA6 183-2BC
1MA6 206-2BC
1MA6 207-2BC
1MA6 223-2BC
1MA6 223-2AC
1MA6 253-2BC
1MA6 253-2AC
1MA6 280-2BD
1MA6 280-2AD
1MA6 283-2BD
1MA6 283-2AD
1MA6 310-2BD
1MA6 310-2AD
1MA6 313-2BD
1MA6 313-2AD
1MA6 316-2BD
1MA6 316-2AD
1MA6 317-2BD
1MA6 317-2AD

34
43
53
58
96
105
115
170
245
246
310
310
415
415
570
570
610
610
790
790
850
850
990
990
1100
1100

1)
1)
1)
1)

3)
3)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY 500 V
For delta connection, overload protection with
phase-failure protection must be provided.
1
6
3
5

1MA6 10 . - . . .
1MA6 11 . - . . .
1MA6 13 . - . . .
1MA6 16 . - . . .
1MA6 18 . - . . .
1MA6 20 . - . . .
1MA6 22 . - . . .
1MA6 25 . - . . .
1MA6 28 . - . . .
1MA6 310 - . . .
1MA6 313 - . . .
1MA6 316 - . . .
1MA6 317 - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 4) 5)
IM V3 4) 6) protective
cover 4) 6) 7)
0

9)

With standard flange With special flange


IM B14, IM B34
IM B14
IM V19 4)
IM V19 4)

8)
8)
8)
8)
8)
8)

10)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/17.

4/16

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque
class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment
of inertia

J
kgm

Noise at rated output

tE time

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

for
temperature class
T1/T2
tE
s

for
temperature class
T3
tE
s

74
75
80
80
82
82
82
83
84
84
84
84
89
89
91
91
91
91
93
93
93
93
93
93
93
93

9
10
15
15
29
23
23
30
35
35
30
16
30
18
30
19
27
15
50
30
40
21
40
17
30
7

8
9
13
13
18
12
9
14
14
10
13

11

23

11

21

19

11

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA6 106-2BA
1MA6 113-2BB
1MA6 130-2BB
1MA6 131-2BB
1MA6 163-2BB
1MA6 164-2BB
1MA6 166-2BB
1MA6 183-2BC
1MA6 206-2BC
1MA6 207-2BC
1MA6 223-2BC
1MA6 223-2AC
1MA6 253-2BC
1MA6 253-2AC
1MA6 280-2BD
1MA6 280-2AD
1MA6 283-2BD
1MA6 283-2AD
1MA6 310-2BD
1MA6 310-2AD
1MA6 313-2BD
1MA6 313-2AD
1MA6 316-2BD
1MA6 316-2AD
1MA6 317-2BD
1MA6 317-2AD

2.6
2.1
1.9
2.2
2.2
2.1
2.3
2
1.9
2
1.8
1.8
1.5
1.5
1.5
1.5
1.5
1.5
1.4
1.5
1.6
1.4
1.4
1.6
1.5
1.8

7.4
6.6
6.8
7.7
7.6
7.6
7.6
6.9
6
6.4
6.4
7
6.6
6.5
7.1
7.8
7.2
7.5
7.1
7.3
7
7.5
6.8
7.4
7.3
9.3

2.8
2.3
2.5
2.7
3.1
2.9
3
3.3
2.9
3
2.7
2.7
2.7
2.7
2.9
2.9
2.8
2.8
2.8
2.9
2.8
2.7
2.7
2.9
2.5
2.9

1)

For the following versions T3-output is stamped as standard:


order code A11/A12
voltage code 9
Alternative: order code C30 T1/T2-output on the rating plate

2)

For connection to 230 V, parallel supply cables are necessary (see the
Introduction section, Connection, circuit and connection box).

3)

Technical data and dimensions are available for VIK version (order code
K30) on request (additional charge).

4)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

16
13
13
13
13
13
13
10
10
10
10
10
10
10
7
7
7
7
7
7
7
7
7
7
7
7

0.0038
0.0055
0.016
0.021
0.034
0.04
0.052
0.077
0.14
0.16
0.24
0.24
0.45
0.45
0.79
0.79
0.92
0.92
1.3
1.3
1.5
1.5
1.8
1.8
2.3
2.3

62
63
68
68
70
70
70
70
71
71
71
71
75
75
77
77
77
77
79
79
79
79
79
79
79
79

5)

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

6)

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

7)

The Second shaft extension option, order code K16 is not possible.

8)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

9)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

10)

2-pole motors in 60 Hz version available on request.

Siemens D 81.1 2007

4/17

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power fac- Rated


tor at 50 Hz current at
380 ... 420 V,
50 Hz
cos rated

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

Irated
A

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)

6.5
9.5
13
16
19
25
31

6.5
9.5
13
16
19
25
31

T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2

132 S
160 M
160 M
160 L
180 M
200 L
200 L

2900
2920
2910
2910
2935
2960
2950

21
31
43
53
62
81
100

85
87
87.5
87
91.1
90.6
91.4

0.91
0.88
0.92
0.93
0.88
0.86
0.88

12.6
18.6
24.5
30
36.5
39
60

1MA6 131-2BB
1MA6 163-2BB
1MA6 164-2BB
1MA6 166-2BB
1MA6 183-2BC
1MA6 206-2BC
1MA6 207-2BC

2)

58
96
105
115
170
245
246

2)
1) 2)
1) 2)
1)
1)
1)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY 500 V
For delta connection, overload protection with
phase-failure protection must be provided.
1
6
3
5

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 3) 4)
IM V3 3) 5) protective
cover 3) 5) 6)
0

7)
7)

1MA6 13 . - . . .
1MA6 16 . - . . .
1MA6 18 . - . . .
1MA6 20 . - . . .

With standard flange With special


flange
IM B14, IM B34
IM B14
3)
IM V19
IM V19 3)
2

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

Utilization according to temperature class 155 (F).

4)

2)

For the following versions T3-output is stamped as standard:


order code A11/A12
voltage code 9
Alternative: order code C30 T1/T2-output on the rating plate

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

5)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

6)

The Second shaft extension option, order code K16 is not possible.

7)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

3)

4/18

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia tE time

J
kgm

for
temperature
class
T1/T2
tE
s

for
temperature
class
T3
tE
s

12
24
16
5
24
28
26

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)
1MA6 131-2BB
1MA6 163-2BB
1MA6 164-2BB
1MA6 166-2BB
1MA6 183-2BC
1MA6 206-2BC
1MA6 207-2BC

1.9
1.7
1.6
1.8
1.6
1.5
1.5

6.5
6
5.8
5.8
5.5
4.8
4.9

2.3
2.4
2.2
2.3
2.6
2.3
2.3

13
13
13
13
10
10
10

0.021
0.034
0.04
0.052
0.077
0.14
0.16

Siemens D 81.1 2007

4/19

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3

2
2.5
3.6
5
6.8
10
13.5
15
17.5
24
30
36
44
58
70
84
100
115
135

2
2.5
3.6
5
6.8
10
13.5
15
17.5
24
30
36
44
58
70
84
100
115
135

T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3

100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

1420
1415
1435
1445
1460
1455
1465
1470
1470
1475
1481
1484
1485
1488
1488
1492
1492
1490
1492

14
17
24
33
44
66
88
97
114
155
193
232
283
372
449
538
640
740
868

80
81
85
86
87
88
89
90.7
91.6
92.5
93.3
93.8
94
94.6
94.8
95.4
95.8
95.6
95.8

0.82
0.83
0.83
0.82
0.82
0.87
0.84
0.8
0.8
0.82
0.83
0.84
0.85
0.84
0.85
0.84
0.85
0.86
0.86

4.5
5.5
7.5
10.4
14
19.7
27
31
36
47.5
59
70 1)
83
111
130
158
185
214
245

1MA6 106-4BA
1MA6 107-4BA
1MA6 113-4BA
1MA6 130-4BA
1MA6 133-4BA
1MA6 163-4BB
1MA6 166-4BB
1MA6 183-4BC
1MA6 186-4BC
1MA6 207-4BC
1MA6 220-4BC
1MA6 223-4BC
1MA6 253-4BC
1MA6 280-4BC
1MA6 283-4BC
1MA6 310-4BD
1MA6 313-4BD
1MA6 316-4BD
1MA6 317-4BD

33
36
45
55
62
100
114
165
177
280
300
330
435
610
660
830
910
1060
1200

2)
2)

2)
2)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

1MA6 10 . - . . .
1MA6 11 . - . . .
1MA6 13 . - . . .
1MA6 16 . - . . .
1MA6 18 . - . . .
1MA6 20 . - . . .
1MA6 22 . - . . .
1MA6 25 . - . . .
1MA6 28 . - . . .
1MA6 310 - . . .
1MA6 313 - . . .
1MA6 316 - . . .
1MA6 317 - . . .

230 V/400 VY 400 V/690 VY 500 VY 500 V


For delta connection, overload protection with
phase-failure protection must be provided.

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 3) 4)
IM V3 3) 5) with protective cover

With standard flange With special


flange
IM B14, IM B34
IM B14
3)
IM V19
IM V19 3)

3) 5) 6)

8)

7)
7)
7)
7)
7)
7)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/21.

4/20

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque
class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment
of inertia

J
kgm

Noise at rated output

tE time

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

for
temperature class
T1/T2
tE
s

for
temperature class
T3
tE
s

65
65
65
74
74
78
78
76
76
78
78
78
79
81
81
83
83
83
83

13
12
10
10
10
17
18
18
16
20
13
12
18
30
26
28
29
28
26

11
10
9
9
9
10
9
11
11
11
13
12
11
7
6
8
7
5
7

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA6 106-4BA
1MA6 107-4BA
1MA6 113-4BA
1MA6 130-4BA
1MA6 133-4BA
1MA6 163-4BB
1MA6 166-4BB
1MA6 183-4BC
1MA6 186-4BC
1MA6 207-4BC
1MA6 220-4BC
1MA6 223-4BC
1MA6 253-4BC
1MA6 280-4BC
1MA6 283-4BC
1MA6 310-4BD
1MA6 313-4BD
1MA6 316-4BD
1MA6 317-4BD

2.5
2.6
2.6
2.7
3
2.3
2.4
1.8
1.8
2.1
1.6
1.7
1.7
1.7
1.7
1.7
1.6
1.7
1.7

6.4
6.4
7.2
6.6
7.7
6.5
6.9
6.1
6.4
7.9
6.7
6.9
7.3
6.3
7
7.7
7.2
7.5
7.8

2.7
2.7
2.9
3.2
3.6
2.7
3
2.9
3
3
2.7
2.8
2.5
2.5
2.5
2.8
2.5
2.5
2.8

1)

For connection to 230 V, parallel supply cables are necessary (see the
Introduction section, Connection, circuit and connection box).

2)

Technical data and dimensions are available for VIK version (order code
K30) on request (additional charge).

3)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

4)

16
16
16
16
16
13
13
10
10
10
10
10
10
10
10
7
7
7
7

0.0048
0.0058
0.011
0.021
0.027
0.052
0.057
0.13
0.15
0.24
0.44
0.52
0.79
1.4
1.6
2.2
2.7
3.2
4.2

53
53
53
62
62
66
66
63
63
65
65
65
65
67
67
69
69
69
69

5)

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

6)

The Second shaft extension option, order code K16 is not possible.

7)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

8)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

Siemens D 81.1 2007

4/21

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)

17
20
27
33
40
50
68
80
100
120
135
165

17
20
27
33
40
50
68
80
100
120
135
165

T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2

180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

1460
1465
1475
1480
1480
1485
1485
1485
1490
1488
1488
1485

111
130
175
213
258
322
437
514
641
770
868
1061

90
90.6
92.4
93.1
93.6
93.8
94.5
94.8
95.3
95.7
95.5
95.8

0.82
0.82
0.84
0.84
0.85
0.86
0.85
0.87
0.85
0.86
0.86
0.87

35.5
41 2)
53
64 2)
77 2)
94
131
150 2)
188
222 2)
248
305

1MA6 183-4BC
1MA6 186-4BC
1MA6 207-4BC
1MA6 220-4BC
1MA6 223-4BC
1MA6 253-4BC
1MA6 280-4BC
1MA6 283-4BC
1MA6 310-4BD
1MA6 313-4BD
1MA6 316-4BD
1MA6 317-4BD

1)

165
177
280
300
330
435
610
660
830
910
1060
1200

1)

3)
3)

3)
3)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

1MA6 18 . - . . .
1MA6 20 . - . . .
1MA6 22 . - . . .
1MA6 25 . - . . .
1MA6 28 . - . . .
1MA6 310 - . . .
1MA6 313 - . . .
1MA6 316 - . . .
1MA6 317 - . . .

230 V/400 VY 400 V/690 VY 500 VY 500 V


For delta connection, overload protection with
phase-failure protection must be provided.

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 4) 5)
IM V3 4) 6) with protective cover

With standard flange With special flange


IM B14, IM B34
IM B14
IM V19 4)
IM V19 4)

4) 6) 7)

9)

1
8)
8)
8)
8)
8)
8)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

Utilization according to temperature class 155 (F).

5)

2)

For connection to 230 V, parallel supply cables are necessary (see the
Introduction section, Connection, circuit and connection box).

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

3)

Technical data and dimensions are available for VIK version (order code
K30) on request (additional charge).

6)

4)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

7)

The Second shaft extension option, order code K16 is not possible.

8)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

9)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

4/22

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia tE time

J
kgm

for
temperature
class
T1/T2
tE
s

for
temperature
class
T3
tE
s

13
13
19
11
10
15
23
20
24
24
21
17

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)
1MA6 183-4BC
1MA6 186-4BC
1MA6 207-4BC
1MA6 220-4BC
1MA6 223-4BC
1MA6 253-4BC
1MA6 280-4BC
1MA6 283-4BC
1MA6 310-4BD
1MA6 313-4BD
1MA6 316-4BD
1MA6 317-4BD

1.6
1.6
1.9
1.4
1.5
1.5
1.5
1.5
1.4
1.3
1.4
1.5

5.3
5.6
7.1
6.2
6.2
6.4
5.3
6
6.5
6
6.4
6.3

2.4
2.6
2.7
2.5
2.5
2.1
2.1
2.2
2.4
2.1
2.1
2.3

10
10
10
10
10
10
10
10
7
7
7
7

0.13
0.15
0.24
0.44
0.52
0.79
1.4
1.6
2.2
2.7
3.2
4.2

Siemens D 81.1 2007

4/23

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3

1.3
1.9
2.6
3.5
4.8
6.6
9.7
13.2
16.5
20
27
33
40
46
64
76
92
110
125

1.3
1.9
2.6
3.5
4.8
6.6
9.7
13.2
16.5
20
27
33
40
46
64
76
92
110
125

T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T1,T2,T3
T3
T3
T3
T3
T3
T3

100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L

935
940
945
955
950
960
965
975
980
980
980
985
990
988
991
991
991
991
991

13
19
26
35
48
65
96
129
161
195
263
320
386
445
617
732
887
1060
1210

77
79
79
81
83
85
88
89.6
90.5
90.8
92.5
93
93.3
93.5
94.3
94.6
95
95.2
95.2

0.73
0.76
0.75
0.72
0.76
0.75
0.76
0.78
0.81
0.82
0.82
0.83
0.85
0.86
0.84
0.84
0.85
0.84
0.86

3.35
4.7
6.5
9
11.4
14.9
21
28.5
34.5
41
54
66
77
86
124
146
172
210
220

1MA6 106-6BA
1MA6 113-6BB
1MA6 130-6BB
1MA6 133-6BB
1MA6 134-6BB
1MA6 163-6BB
1MA6 166-6BB
1MA6 186-6BC
1MA6 206-6BC
1MA6 207-6BC
1MA6 223-6BC
1MA6 253-6BC
1MA6 280-6BC
1MA6 283-6BC
1MA6 310-6BC
1MA6 313-6BC
1MA6 316-6BC
1MA6 317-6BC
1MA6 318-6BC

33
40
50
57
66
103
122
177
220
235
305
410
540
580
770
830
970
1060
1100

1)
1) 2)

Order No. supplements


Motor type

Penultimate position: Voltage code

230 V/400 VY 400 V/690 VY 500 VY 500 V


For delta connection, overload protection with
phase-failure protection must be provided.

Final position:
Type of construction code
Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 3) 4)
IM V3 3) 5) with protective cover

50 Hz

1MA6 10 . - . . .
1MA6 11 . - . . .
1MA6 13 . - . . .
1MA6 16 . - . . .
1MA6 18 . - . . .
1MA6 20 . - . . .
1MA6 22 . - . . .
1MA6 25 . - . . .
1MA6 28 . - . . .
1MA6 310 - . . .
1MA6 313 - . . .
1MA6 316 - . . .
1MA6 317 - . . .
1MA6 318 - . . .

With standard flange With special


flange
IM B14, IM B34
IM B14
3)
IM V19
IM V19 3)

3) 5) 6)

8)

7)
7)
7)
7)
7)
7)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/25.

4/24

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque
class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment
of inertia

J
kgm

Noise at rated output

tE time

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound
pressure
level
at 50 Hz
LWA
dB(A)

for
temperature class
T1/T2
tE
s

for
temperature class
T3
tE
s

59
64
75
75
75
78
78
78
78
78
78
74
74
74
77
77
77
77
77

26
19
21
16
13
18
15
22
23
22
15
16
13
0
0
0
0
0
0

26
16
18
13
11
9
8
18
19
17
15
16
13
12
14
8
9
6
6

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T3
1MA6 106-6BA
1MA6 113-6BB
1MA6 130-6BB
1MA6 133-6BB
1MA6 134-6BB
1MA6 163-6BB
1MA6 166-6BB
1MA6 186-6BC
1MA6 206-6BC
1MA6 207-6BC
1MA6 223-6BC
1MA6 253-6BC
1MA6 280-6BC
1MA6 283-6BC
1MA6 310-6BC
1MA6 313-6BC
1MA6 316-6BC
1MA6 317-6BC
1MA6 318-6BC

2.4
2.3
1.8
2.3
2.4
2.7
2.8
1.6
1.7
1.7
1.6
1.6
1.5
1.6
1.7
1.7
1.7
1.7
1.6

4.8
5
4.4
5.1
5.6
6.4
7.7
5.4
5.4
5.6
5.6
5.3
6.2
6.5
6.2
6.4
6.5
6.8
7

2.5
2.5
2.4
2.8
2.8
3.1
2.2
2.5
2.6
2.6
2.5
2.4
2.6
2.5
2.5
2.5
2.5
2.5
2.5

1)

Technical data and dimensions are available for VIK version (order code
K30) on request (additional charge).

2)

Only certified for rated voltage of 400 V.

3)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

4)

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

16
13
13
13
13
13
13
10
10
10
10
10
10
10
10
10
10
10
10

0.0063
0.011
0.015
0.019
0.025
0.041
0.055
0.2
0.29
0.33
0.57
0.89
1.3
1.5
2.4
2.9
3.5
4.3
4.9

47
52
63
63
63
66
66
66
66
66
66
60
60
60
63
63
63
63
63

5)

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

6)

The Second shaft extension option, order code K16 is not possible.

7)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

8)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

Siemens D 81.1 2007

4/25

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Prated
kW

Temperature class

Prated
kW

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz

FS

nrated
rpm

Trated
Nm

rated

Power
factor
at 50 Hz

Rated
current at
380 ... 420 V,
50 Hz

cos rated

Irated
A

Order No.
For Order No.
supplements for
voltage and
type of construction,
see table below

Price

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)

50
68
82
98
120
135

50
68
82
98
120
135

T1,T2
T1,T2
T1,T2
T1,T2
T1,T2
T1,T2

280 M
315 S
315 M
315 L
315 L
315 L

987
990
990
990
990
990

484
656
791
945
1160
1300

93.3
94.2
94.5
94.8
95
95

0.86
0.85
0.84
0.85
0.85
0.86

96
131
158
185
230
240 2)

1MA6 283-6BC
1MA6 310-6BC
1MA6 313-6BC
1MA6 316-6BC
1MA6 317-6BC
1MA6 318-6BC

580
770
830
970
1060
1100

1)
1)

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

1MA6 28 . - . . .
1MA6 310 - . . .
1MA6 313 - . . .
1MA6 316 - . . .
1MA6 317 - . . .
1MA6 318 - . . .

230 V/400 VY 400 V/690 VY 500 VY 500 V


For delta connection, overload protection with
phase-failure protection must be provided.

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 3) 4)
IM V3 3) 5) with protective cover

With standard flange With special


flange
IM B14, IM B34
IM B14
IM V19 3)
IM V19 3)

3) 5) 6)

8)

1
7)
7)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

Technical data and dimensions are available for VIK version (order code
K30) on request (additional charge).

5)

2)

Only certified for rated voltage of 400 V.

3)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

1MA6 220-... to 1MA6 318-... motors (motor series 1MA6 frame sizes
225 S to 315 L) are supplied with two screw-in eyebolts in accordance
with IM B5, whereby one can be relocated in accordance with IM V1 or
IM V3. It is important to note that stress must not be applied perpendicular
to the ring plane.

6)

The Second shaft extension option, order code K16 is not possible.

7)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

8)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

4)

If motors 1MA6 183-... to 1MA6 318-... (motor series 1MA6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

4/26

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zone 1 with type of protection "e"
Cast-iron series 1MA6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia tE time

J
kgm

for
temperature
class
T1/T2
tE
s

for
temperature
class
T3
tE
s

14
22
18
20
16
17

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 and T2, with double rating plate (T1/T2 and T3)
1MA6 283-6BC
1MA6 310-6BC
1MA6 313-6BC
1MA6 316-6BC
1MA6 317-6BC
1MA6 318-6BC

1.5
1.6
1.6
1.6
1.6
1.5

5.8
5.9
5.9
6.1
6.2
6.5

2.3
2.3
2.3
2.3
2.3
2.3

10
10
10
10
10
10

1.5
2.4
2.9
3.5
4.3
4.9

Siemens D 81.1 2007

4/27

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz 1)

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4

0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132

0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
17.3
21.3
24.5
33.5
41.5
51
62
84
101
123
148

71 M
71 M
80 M
80 M
90 L
90 L
100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M

2750
2790
2840
2835
2850
2860
2885
2895
2925
2930
2940
2940
2940
2940
2940
2945
2955
2965
2975
2975
2980
2980

1.3
1.9
2.5
3.7
5
7.4
9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
353
423

67
71
72
74
78
80
82
84
85
87
88
89
91
92
92.3
92.8
93.9
94
94.7
95.1
94.8
95.1

0.81
0.81
0.86
0.87
0.84
0.86
0.85
0.88
0.89
0.89
0.88
0.91
0.91
0.88
0.89
0.9
0.9
0.9
0.9
0.91
0.9
0.9

0.98
1.38
1.75
2.45
3.3
4.6
6.2
7.8
10.5
14.5
20.5
26.5
32.5
39
53
64
77 1)
93
128 1)
150 1)
186 1)
225 1)

19
20
24
26
32
35
44
57
75
82
123
134
161
175
250
266
335
445
600
640
840
900

1MJ6 070-2CA
1MJ6 073-2CA
1MJ6 080-2CA
1MJ6 083-2CA
1MJ6 096-2CA
1MJ6 097-2CA
1MJ6 106-2CA
1MJ6 113-2CA
1MJ6 130-2CA
1MJ6 131-2CA
1MJ6 163-2CA
1MJ6 164-2CA
1MJ6 166-2CA
1MJ6 183-2CA
1MJ6 206-2CA
1MJ6 207-2CA
1MJ7 223-2CB
1MJ7 253-2CB
1MJ7 280-2CC
1MJ7 283-2CC
1MJ7 310-2CC
1MJ7 313-2CC

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1MJ6 07 . - . . .
1MJ6 08 . - . . .
1MJ6 09 . - . . .
1MJ6 10 . - . . .
1MJ6 11 . - . . .
1MJ6 13 . - . . .
1MJ6 16 . - . . .
1MJ6 18 . - . . .
1MJ6 20 . - . . .
1MJ7 22 . - . . .
1MJ7 25 . - . . .
1MJ7 28 . - . . .
1MJ7 31 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 2) 3)
IM V3 2) 4) protective
cover 2) 4) 5)
0
1
4
6

6)

6)

6)

6)

6)

6)

With standard flange With special


flange
IM B14, IM B34
IM B14
IM V19 2)
IM V19 2)
2

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/29.

4/28

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

52
52
56
56
60
60
62
63
68
68
70
70
70
70
71
71
71
75
77
77
79
79

63
63
67
67
72
72
74
75
80
80
82
82
82
83
84
84
84
89
91
91
93
93

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ6 070-2CA
1MJ6 073-2CA
1MJ6 080-2CA
1MJ6 083-2CA
1MJ6 096-2CA
1MJ6 097-2CA
1MJ6 106-2CA
1MJ6 113-2CA
1MJ6 130-2CA
1MJ6 131-2CA
1MJ6 163-2CA
1MJ6 164-2CA
1MJ6 166-2CA
1MJ6 183-2CA
1MJ6 206-2CA
1MJ6 207-2CA
1MJ7 223-2CB
1MJ7 253-2CB
1MJ7 280-2CC
1MJ7 283-2CC
1MJ7 310-2CC
1MJ7 313-2CC

2.3
2.3
2.4
2.6
2.5
2.8
2.8
2.4
2
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.3
2.1
1.9
2
1.8
1.9

4.3
5.3
6.3
6.3
6.7
7.1
7.7
7.6
5.9
6.9
6.5
6.6
7
6.9
6.5
7.7
6.9
6.9
7
7
7
7

2.3
2.3
2.3
2.3
2.5
2.8
3
2.8
2.6
2.6
2.6
3.1
3.3
3.2
2.8
2.8
2.7
2.8
2.7
2.7
2.8
2.8

1)

For connection to 230 V, parallel feeders are necessary (see the


Introduction section, Connection, circuit and connection boxes).

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
13
13
10
10
10
10

0.00035
0.00045
0.00085
0.0011
0.0015
0.002
0.0038
0.0055
0.01
0.01
0.03
0.04
0.05
0.07
0.14
0.16
0.24
0.45
0.79
0.92
1.3
1.5

4)

1MJ7 220-... to 1MJ7 313-... motors (motor series 1MJ7 frame sizes 225 S
to 315 M) are supplied with two screw-in eyebolts in accordance with
IM B5, whereby one can be relocated in accordance with IM V1 or IM V3.
It is important to note that stress must not be applied perpendicular to the
ring plane.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

If motors 1MJ6 183-... to 1MJ7 313-... (motor series 1MJ6 frame size
180 M and above to 1MJ7 frame size 315 M) in types of construction with
feet IM B6, IM B7 or IM V6 are fixed to the wall, it is recommended that the
motor feet are supported.

Siemens D 81.1 2007

4/29

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz 1)

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4

0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132

0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
17.3
21.3
25.3
34.5
42.5
52
63
86
104
127
152

71 M
71 M
80 M
80 M
90 L
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M

1325
1375
1395
1395
1410
1420
1420
1415
1435
1450
1450
1455
1455
1460
1460
1465
1475
1475
1480
1485
1485
1486
1486

1.8
2.5
3.7
5.1
7.5
10
15
20
27
36
49
72
98
121
144
196
240
292
355
482
579
707
848

60
64
71
73
73
77
78
80
83
86
86
87
89
90.5
91.2
91.8
93
93.4
94
94.7
95
94.8
95.5

0.77
0.74
0.79
0.79
0.80
0.8
0.8
0.82
0.82
0.83
0.84
0.85
0.85
0.84
0.85
0.86
0.86
0.87
0.87
0.86
0.86
0.86
0.86

0.78
1.13
1.42
1.88
2.7
3.5
5.1
6.6
8
11.1
15
21.5
28.5
35
41
55
67 1)
80 1)
97 1)
132 1)
160 1)
194 1)
232 1)

20
21
24
26
32
35
44
47
58
76
85
128
158
175
189
247
325
355
465
630
680
870
950

1MJ6 070-4CB
1MJ6 073-4CB
1MJ6 080-4CA
1MJ6 083-4CA
1MJ6 096-4CA
1MJ6 097-4CA
1MJ6 106-4CA
1MJ6 107-4CA
1MJ6 113-4CA
1MJ6 130-4CA
1MJ6 133-4CA
1MJ6 163-4CA
1MJ6 166-4CA
1MJ6 183-4CA
1MJ6 186-4CA
1MJ6 207-4CA
1MJ7 220-4CA
1MJ7 223-4CA
1MJ7 253-4CA
1MJ7 280-4CA
1MJ7 283-4CA
1MJ7 310-4CA
1MJ7 313-4CA

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1MJ6 07 . - . . .
1MJ6 08 . - . . .
1MJ6 09 . - . . .
1MJ6 10 . - . . .
1MJ6 11 . - . . .
1MJ6 13 . - . . .
1MJ6 16 . - . . .
1MJ6 18 . - . . .
1MJ6 20 . - . . .
1MJ7 22 . - . . .
1MJ7 25 . - . . .
1MJ7 28 . - . . .
1MJ7 31 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 2) 3)
IM V3 2) 4) protective
cover 2) 4) 5)
0
1
4
6

6)

6)

6)

6)

6)

6)

With standard flange With special


flange
IM B14, IM B34
IM B14
2)
IM V19
IM V19 2)
2

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/31.

4/30

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

44
44
47
47
48
48
53
53
53
62
62
66
66
63
63
65
65
65
65
67
67
69
69

55
55
58
58
60
60
65
65
65
74
74
78
78
76
76
78
78
78
79
81
81
83
83

LWA
dB(A)

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ6 070-4CB
1MJ6 073-4CB
1MJ6 080-4CA
1MJ6 083-4CA
1MJ6 096-4CA
1MJ6 097-4CA
1MJ6 106-4CA
1MJ6 107-4CA
1MJ6 113-4CA
1MJ6 130-4CA
1MJ6 133-4CA
1MJ6 163-4CA
1MJ6 166-4CA
1MJ6 183-4CA
1MJ6 186-4CA
1MJ6 207-4CA
1MJ7 220-4CA
1MJ7 223-4CA
1MJ7 253-4CA
1MJ7 280-4CA
1MJ7 283-4CA
1MJ7 310-4CA
1MJ7 313-4CA

1.8
2
2.3
2.5
2.1
2.2
2.2
2.7
2.8
2.4
2.7
2.4
2.8
2.3
2.3
2.6
2.5
2.6
2.6
2.5
2.5
2.5
2.7

3.2
3.6
4.7
5
4.9
5.8
6
6.4
7.2
6.9
7.7
6.6
7.4
7.1
7.1
7.4
7
7
6.7
6.7
6.8
6.7
7.2

1.8
2
2.4
2.6
2.5
2.6
2.6
3
3
3.3
3.3
2.9
3.2
3
3
3.2
3.1
3.2
2.5
2.7
2.8
2.7
3

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

13
13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.0006
0.0008
0.0015
0.0018
0.0028
0.0035
0.0048
0.0058
0.01
0.01
0.02
0.04
0.05
0.13
0.15
0.24
0.44
0.52
0.79
1.4
1.6
2.2
2.7

4)

1MJ7 220-... to 1MJ7 313-... motors (motor series 1MJ7 frame sizes 225 S
to 315 M) are supplied with two screw-in eyebolts in accordance with
IM B5, whereby one can be relocated in accordance with IM V1 or IM V3.
It is important to note that stress must not be applied perpendicular to the
ring plane.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

If motors 1MJ6 183-... to 1MJ7 313-... (motor series 1MJ6 frame size
180 M and above to 1MJ7 frame size 315 M) in types of construction with
feet IM B6, IM B7 or IM V6 are fixed to the wall, it is recommended that the
motor feet are supported.

Siemens D 81.1 2007

4/31

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz 1)

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
temperature classes T1 to T4

0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90

0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
18
22
26.5
36
44.5
54
66
90
108

71 M
80 M
80 M
90 L
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M

870
910
900
910
905
930
945
945
945
950
960
960
970
975
975
978
980
982
984
988
988

2.7
3.9
5.8
8
12
15
22
30
40
55
75
109
148
181
215
293
361
438
534
725
870

63
64
64
68
72
75
76
78
79
83
86
87
89
90.2
90.8
92
92.4
93
93.6
93.8
94.2

0.7
0.71
0.74
0.74
0.75
0.73
0.76
0.75
0.76
0.76
0.72
0.74
0.83
0.82
0.83
0.84
0.84
0.86
0.86
0.85
0.85

0.82
1.18
1.67
2.15
2.95
4
5.5
7.4
9.6
12.6
17.5
24.5
29.5
36
42.5
56
69
81
99 1)
136
162 1)

16
35
22.5
32
32
39
52
78
85
92
134
167
190
240
255
330
440
560
600
810
870

1MJ6 073-6CA
1MJ6 080-6CA
1MJ6 083-6CA
1MJ6 096-6CA
1MJ6 097-6CA
1MJ6 106-6CA
1MJ6 113-6CA
1MJ6 130-6CA
1MJ6 133-6CA
1MJ6 134-6CA
1MJ6 163-6CA
1MJ6 166-6CA
1MJ6 186-6CA
1MJ6 206-6CA
1MJ6 207-6CA
1MJ7 223-6CA
1MJ7 253-6CA
1MJ7 280-6CA
1MJ7 283-6CA
1MJ7 310-6CA
1MJ7 313-6CA

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1MJ6 07 . - . . .
1MJ6 08 . - . . .
1MJ6 09 . - . . .
1MJ6 10 . - . . .
1MJ6 11 . - . . .
1MJ6 13 . - . . .
1MJ6 16 . - . . .
1MJ6 18 . - . . .
1MJ6 20 . - . . .
1MJ7 22 . - . . .
1MJ7 25 . - . . .
1MJ7 28 . - . . .
1MJ7 31 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 2) 3)
IM V3 2) 4) protective
cover 2) 4) 5)
0
1
4
6

6)

6)

6)

6)

6)

6)

With standard flange With special


flange
IM B14, IM B34
IM B14
2)
IM V19
IM V19 2)
2

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/33.

4/32

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

39
40
40
43
43
47
52
63
63
63
66
66
66
66
66
66
60
60
60
63
63

50
51
51
55
55
59
64
75
75
75
78
78
78
78
78
78
74
74
74
77
77

LWA
dB(A)

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
temperature classes T1 to T4
1MJ6 073-6CA
1MJ6 080-6CA
1MJ6 083-6CA
1MJ6 096-6CA
1MJ6 097-6CA
1MJ6 106-6CA
1MJ6 113-6CA
1MJ6 130-6CA
1MJ6 133-6CA
1MJ6 134-6CA
1MJ6 163-6CA
1MJ6 166-6CA
1MJ6 186-6CA
1MJ6 206-6CA
1MJ6 207-6CA
1MJ7 223-6CA
1MJ7 253-6CA
1MJ7 280-6CA
1MJ7 283-6CA
1MJ7 310-6CA
1MJ7 313-6CA

2.2
1.9
2
2.2
2.4
2.3
2.2
2
2
2.2
2.1
2.3
2.6
2.6
2.5
2.6
2.6
2.4
2.5
2.4
2.4

3.1
3.3
3.5
3.9
4.3
4.5
4.8
4.8
5
5.4
5.1
5.5
6.3
6.3
5.7
5.7
6
6
6.2
6.2
6.2

2.2
2
2.1
2.3
2.4
2.5
2.5
2.2
2.4
2.5
2.5
2.5
2.4
2.3
2.3
2.2
2.1
2.3
2.4
2.5
2.5

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.0009
0.0015
0.0018
0.0028
0.0035
0.0063
0.01
0.01
0.01
0.02
0.04
0.04
0.2
0.29
0.33
0.57
0.89
1.3
1.5
2.4
2.9

4)

1MJ7 220-... to 1MJ7 313-... motors (motor series 1MJ7 frame sizes 225 S
to 315 M) are supplied with two screw-in eyebolts in accordance with
IM B5, whereby one can be relocated in accordance with IM V1 or IM V3.
It is important to note that stress must not be applied perpendicular to the
ring plane.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

If motors 1MJ6 183-... to 1MJ7 313-... (motor series 1MJ6 frame size
180 M and above to 1MJ7 frame size 315 M) in types of construction with
feet IM B6, IM B7 or IM V6 are fixed to the wall, it is recommended that the
motor feet are supported.

Siemens D 81.1 2007

4/33

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4

0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75

0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
13.2
18
22
26.5
36
44.5
54
66
90

90 L
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M

655
655
685
685
700
695
700
715
710
715
725
725
725
725
730
732
734
738
738

5.3
7.9
10
16
21
30
40
54
74
100
145
198
244
290
392
483
585
712
970

61
65
65
74
74
74
76
81
83
84
87
87.5
88.6
90.1
91.6
92.7
92.8
93.1
93.6

0.76
0.76
0.72
0.74
0.73
0.72
0.72
0.72
0.72
0.72
0.7
0.78
0.8
0.81
0.81
0.82
0.83
0.82
0.82

1.16
1.62
2.3
2.9
4
6
7.9
9.9
13.3
17.9
26
32
37.5
43.5
58
70
84
104
140

27.5
29.5
40
48
52
78
85
119
134
159
191
263
325
350
465
570
620
780
890

1MJ6 096-8CB
1MJ6 097-8CB
1MJ6 106-8CB
1MJ6 107-8CB
1MJ6 113-8CB
1MJ6 130-8CB
1MJ6 133-8CB
1MJ6 163-8CB
1MJ6 164-8CB
1MJ6 166-8CB
1MJ6 186-8CB
1MJ6 207-8CB
1MJ7 220-8CB
1MJ7 223-8CB
1MJ7 253-8CB
1MJ7 280-8CB
1MJ7 283-8CB
1MJ7 310-8CB
1MJ7 313-8CB

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1MJ6 07 . - . . .
1MJ6 08 . - . . .
1MJ6 09 . - . . .
1MJ6 10 . - . . .
1MJ6 11 . - . . .
1MJ6 13 . - . . .
1MJ6 16 . - . . .
1MJ6 18 . - . . .
1MJ6 20 . - . . .
1MJ7 22 . - . . .
1MJ7 25 . - . . .
1MJ7 28 . - . . .
1MJ7 31 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1 with IM B35
IM V6 1) 2)
IM V3 ) 3) protective
cover 1) 3) 4)
0
1
4
6

5)

5)

5)

5)

5)

5)

With standard flange With special


flange
IM B14, IM B34
IM B14
1)
IM V19
IM V19 1)
2

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/35.

4/34

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Cast-iron series 1MJ6 and 1MJ7

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

41
41
45
45
49
53
53
63
63
63
60
58
58
58
57
58
58
62
62

53
53
57
57
61
65
65
75
75
75
73
71
71
71
71
72
72
76
76

LWA
dB(A)

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ6 096-8CB
1MJ6 097-8CB
1MJ6 106-8CB
1MJ6 107-8CB
1MJ6 113-8CB
1MJ6 130-8CB
1MJ6 133-8CB
1MJ6 163-8CB
1MJ6 164-8CB
1MJ6 166-8CB
1MJ6 186-8CB
1MJ6 207-8CB
1MJ7 220-8CB
1MJ7 223-8CB
1MJ7 253-8CB
1MJ7 280-8CB
1MJ7 283-8CB
1MJ7 310-8CB
1MJ7 313-8CB

1.4
1.5
1.6
1.8
1.8
1.7
1.9
2.1
2.3
2.6
2
2.1
2.1
2.1
2.1
2.2
2.2
2.2
2.3

2.8
2.9
3.5
3.9
4.4
4.2
4.4
4.8
5.1
5.8
5
5
5
5
5
5.5
5.5
6
6.2

1.7
1.7
1.8
2
2
2.1
2.2
2.3
2.5
2.8
2.2
2.2
2.2
2.2
2.1
2.2
2.2
2.4
2.5

13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13

0.0025
0.0035
0.0053
0.007
0.01
0.01
0.01
0.03
0.04
0.06
0.21
0.37
0.58
0.66
1.1
1.4
1.6
2.3
3

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

1MJ7 220-... to 1MJ7 313-... motors (motor series 1MJ7 frame sizes 225 S
to 315 M) are supplied with two screw-in eyebolts in accordance with
IM B5, whereby one can be relocated in accordance with IM V1 or IM V3.
It is important to note that stress must not be applied perpendicular to the
ring plane.

4)

2)

The Second shaft extension option, order code K16 is not possible.

If motors 1MJ6 183-... to 1MJ7 313-... (motor series 1MJ6 frame size
180 M and above to 1MJ7 frame size 315 M) in types of construction with
feet IM B6, IM B7 or IM V6 are fixed to the wall, it is recommended that the
motor feet are supported.

5)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

Siemens D 81.1 2007

4/35

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Steel/cast-iron series 1MJ8 and 1MJ1

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4

160
200
250
315
355
400
450
500
560
630
710
800
900

185
220
275
355
400
450
500
560
630
710
710
800
900

315 M
315 L
315 L
355
355
355
355
400
400
400
450
450
450

2977
2980
2980
2982
2983
2985
2978
2982
2983
2984
2986
2986
2985

515
640
800
1009
1136
1279
1443
1601
1792
2016
2270
2557
2879

95.6
96
96
96.6
96.7
96.9
96.6
96.8
97
97
97
97.1
97.2

0.87
0.88
0.88
0.89
0.92
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91

280
345
425 1)
530 1)
575
655
740
820
915
595 2)
670 2)
760 2)
850 2)

1160
1400
1550
2000
2150
2250
2600
3200
3200
3500
4200
4500
4500

1MJ1 313-2AC
1MJ1 316-2AC
1MJ1 318-2AC
1MJ8 356-2AC
1MJ8 357-2AD
1MJ8 358-2AD
1MJ1 358-2AE
1MJ1 405-2AE
1MJ1 407-2AE
1MJ1 408-2AE
1MJ1 455-2AE
1MJ1 457-2AE
1MJ1 458-2AE

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
160
200
250
280
315
355
400
450
500
560
630
710
800
900
950

180
220
275
315
355
400
450
500
560
630
710
800
900
1000
on req.

315 M
315 L
315 L
355
355
355
355
355
355
400
400
400
450
450
450

1486
1486
1486
1485
1490
1491
1491
1491
1492
1492
1492
1492
1493
1493
1493

1030
1285
1605
1795
2017
2273
2561
2880
3200
3583
4031
4544
5114
5755
6076

95.8
96
96
96.2
96.6
96.8
96.9
96.8
96.9
96.9
97
97.1
97.1
97.2
97.2

0.84
0.83
0.82
0.85
0.86
0.86
0.86
0.86
0.85
0.88
0.88
0.88
0.88
0.88
0.88

285
360
455 1)
495 1)
540 1)
615
690
785
875
950 3)
1070 1) 3) 4)
1200 1) 3) 4)
1355 1) 3) 4)
880 2)
930 2)

1190
1430
1520
2200
2200
2350
2500
2900
3000
3700
3700
3900
4500
5000
5000

1MJ1 313-4AC
1MJ1 316-4AC
1MJ1 318-4AB
1MJ8 356-4AC
1MJ8 357-4AD
1MJ8 358-4AD
1MJ8 350-4AD
1MJ1 357-4AD
1MJ1 358-4AD
1MJ1 405-4AD
1MJ1 407-4AD
1MJ1 408-4AD
1MJ1 455-4AD
1MJ1 457-4AD
1MJ1 458-4AD

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

1MJ1 31 . - . . .
1MJ8 35 . - . . .
1MJ1 35 . - . . .
1MJ1 40 . - . . .
1MJ1 45 . - . . .

230 V/400 VY 400 V/690 VY 500 VY

500 V

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 5) 6)
IM V3 5) With protective
cover5) 7)
0
1
4
6
8)

With standard flange With special flange


IM B14, IM B34
IM B14,
5)
IM V19
IM V19 5)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/37.

4/36

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Steel/cast-iron series 1MJ8 and 1MJ1

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

77
77
77
82
78
78
80
80
80
82
82
82
82

92
92
92
97
93.5
93.5
96
96
96
98.5
98.5
98.5
98.5

69
71
71
73
73
76
76
76
78
78
78
80
80
80
80

84
85
85
88
88
91.5
91.5
91.5
94
94
94
96.5
96.5
96.5
96.5

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ1 313-2AC
1MJ1 316-2AC
1MJ1 318-2AC
1MJ8 356-2AC
1MJ8 357-2AD
1MJ8 358-2AD
1MJ1 358-2AE
1MJ1 405-2AE
1MJ1 407-2AE
1MJ1 408-2AE
1MJ1 455-2AE
1MJ1 457-2AE
1MJ1 458-2AE

2.3
2.6
2.7
2.1
1.2
1.4
0.95
0.8
0.85
0.85
0.8
0.8
0.85

6.7
7
7
6.7
6.8
7.9
6.2
5.9
6.2
6.2
6.3
6.3
6.4

2.6
2.7
2.6
2.6
2.8
3.2
2.55
2.55
2.7
2.6
2.8
2.8
2.7

10
10
10
10
7
7
5
5
5
5
5
5
5

2.2
2.8
3.5
3.6
3.6
4
5
7
7
8.5
11
13
13

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ1 313-4AC
1MJ1 316-4AC
1MJ1 318-4AB
1MJ8 356-4AC
1MJ8 357-4AD
1MJ8 358-4AD
1MJ8 350-4AD
1MJ1 357-4AD
1MJ1 358-4AD
1MJ1 405-4AD
1MJ1 407-4AD
1MJ1 408-4AD
1MJ1 455-4AD
1MJ1 457-4AD
1MJ1 458-4AD

2.1
2.3
2.6
2.1
1.2
1.25
1.25
1.1
1
1.1
1.1
1.05
1
1.05
1.05

6.5
6.6
6.9
6.6
6.5
6.7
6.7
6.2
6.2
6.2
6.3
6.3
6.6
6.6
6.6

2.5
2.5
2.7
2.3
2.4
2.4
2.4
2.4
2.4
2.55
2.6
2.5
2.6
2.5
2.5

1)

The motors have 2 connection boxes.

2)

Rated current at 690 V.

3)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4)

For connection to 500 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

10
10
13
10
7
7
7
7
7
7
7
7
7
7
7

3.3
3.9
4.7
6.5
7
7.7
8.5
9
9.5
15
15
17
24.5
29
29

5)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

6)

Not possible for types of construction IM B6, IM B7, IM B8 or IM V6.

7)

The Second shaft extension option, order code K16 is not possible.

8)

Not possible for type of construction IM V3.

Siemens D 81.1 2007

4/37

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Steel/cast-iron series 1MJ8 and 1MJ1

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated speed Rated torque Efficiency
at 50 Hz
at 50 Hz
at 50 Hz

Prated
kW

FS

nrated
rpm

Prated
kW

rated

Trated
Nm

Order No.
Power factor Rated
For Order No.
at 50 Hz
current at
supplements for
400 V, 50 Hz voltage and
type of construction,
see table below
cos rated
Irated
A

Price

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4

110
132
160
200
250
280
315
355
400
450
500
560
630
710
800

132
150
170
220
280
315
355
400
450
500
560
630
710
800
900

315 M
315 M
315 L
315 L
355
355
355
355
355
400
400
450
450
450
450

990
990
990
990
994
993
994
993
992
994
994
995
995
995
995

1060
1275
1545
1930
2403
2691
3027
3415
3849
4323
4805
5374
6046
6813
7676

95.2
95.3
95.5
96
96.3
96.3
96.4
96.5
96.5
96.6
96.7
96.9
97
97.1
97.2

0.87
0.87
0.87
0.84
0.85
0.85
0.84
0.85
0.84
0.84
0.84
0.85
0.85
0.85
0.85

195
229
278
355
440
495
560
630
715
800 3)
890 3)
980 1) 3)
1105 1) 3) 4)
1240 1) 3) 4)
815 2)

1180
1180
1390
1550
2300
2500
2600
2700
2700
3700
3700
4700
4700
5000
5000

1MJ1 313-6AB
1MJ1 314-6AB
1MJ1 316-6AB
1MJ1 318-6AB
1MJ8 356-6AD
1MJ8 357-6AD
1MJ8 358-6AD
1MJ1 357-6AD
1MJ1 358-6AD
1MJ1 405-6AD
1MJ1 407-6AD
1MJ1 453-6AD
1MJ1 455-6AD
1MJ1 457-6AD
1MJ1 458-6AD

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
90
110
132
160
200
250
280
315
355
400
450
500
560
630
670

100
120
145
175
225
280
315
355
400
450
500
560
630
710
750

315 M
315 M
315 L
315 L
355
355
355
355
400
400
400
450
450
450
450

740
740
740
742
744
744
743
743
743
744
743
745
745
745
746

1160
1420
1705
2060
2566
3206
3597
4049
4559
5136
5779
6411
7178
8075
8579

94.4
94.4
94.5
94.5
95.4
95.5
96
96
96.2
96.3
96.3
96.7
96.7
96.8
96.9

0.79
0.79
0.79
0.76
0.82
0.81
0.81
0.81
0.81
0.82
0.81
0.83
0.84
0.83
0.83

175
216
255
330
370
466
520
580
655
735
830
900 3)
1000 1) 3) 4)
1130 1) 3) 4)
1210 1) 3) 4)

1240
1240
1390
1530
2250
2600
2700
2850
3400
3700
3900
4700
5100
5100
5300

1MJ1 313-8AC
1MJ1 314-8AC
1MJ1 316-8AC
1MJ1 318-8AC
1MJ8 356-8AD
1MJ8 358-8AD
1MJ1 357-8AD
1MJ1 358-8AD
1MJ1 404-8AD
1MJ1 407-8AD
1MJ1 408-8AD
1MJ1 455-8AE
1MJ1 457-8AE
1MJ1 458-8AE
1MJ1 450-8AE

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

1MJ1 31 . - . . .
1MJ8 35 . - . . .
1MJ1 35 . - . . .
1MJ1 40 . - . . .
1MJ1 45 . - . . .

230 V/400 VY 400 V/690 VY 500 VY

500 V

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 5) 6)
IM V3 5) With protective
cover5) 7)
0
1
4
6
8)

With standard flange With special flange


IM B14, IM B34
IM B14,
5)
IM V19
IM V19 5)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).
For footnotes, see Page 4/39.

4/38

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated in Zone 1 with type of protection "d"
Steel/cast-iron series 1MJ8 and 1MJ1

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

70
70
72
72
75
74
74
74
75
75
75
77
77
77
77

85
85
87
87
90
89.5
89.5
89.5
91
91
91
93.5
93.5
93.5
93.5

69
69
71
71
73
75
75
77
77
77
79
79
79
79
79

84
84
86
86
88
90.5
90.5
93
93
93
96
96
96
96
96

LWA
dB(A)

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ1 313-6AB
1MJ1 314-6AB
1MJ1 316-6AB
1MJ1 318-6AB
1MJ8 356-6AD
1MJ8 357-6AD
1MJ8 358-6AD
1MJ1 357-6AD
1MJ1 358-6AD
1MJ1 405-6AD
1MJ1 407-6AD
1MJ1 453-6AD
1MJ1 455-6AD
1MJ1 457-6AD
1MJ1 458-6AD

2.3
2.4
2.4
2.4
1.35
1.2
1.35
1
1
1
1.05
0.95
0.95
0.95
1

7
6.9
7
7
6.5
6.4
6.6
5.6
5.6
5.5
5.7
5.8
5.7
5.7
5.9

2.3
2.2
2.3
2.5
2.5
2.35
2.5
2.3
2.25
2.25
2.3
2.3
2.3
2.25
2.35

13
13
13
13
7
7
7
7
7
7
7
7
7
7
7

4.9
4.9
6
6.8
9
10.5
11.5
12.5
12.5
21.5
21.5
34
34
40
40

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
temperature classes T1 to T4
1MJ1 313-8AC
1MJ1 314-8AC
1MJ1 316-8AC
1MJ1 318-8AC
1MJ8 356-8AD
1MJ8 358-8AD
1MJ1 357-8AD
1MJ1 358-8AD
1MJ1 404-8AD
1MJ1 407-8AD
1MJ1 408-8AD
1MJ1 455-8AE
1MJ1 457-8AE
1MJ1 458-8AE
1MJ1 450-8AE

1.7
1.7
1.6
1.9
1.15
1.2
1.15
1.05
1
0.95
0.95
0.85
0.85
0.9
0.85

5.8
5.8
5.7
5.7
5.8
5.8
5.2
5.1
5.1
5.2
5
5.2
5.4
5.3
5.2

2
2
2
2.2
2.35
2.45
2.3
2.2
2.3
2.25
2.25
2.2
2.25
2.25
2.3

1)

The motors have 2 connection boxes.

2)

Rated current at 690 V.

3)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4)

For connection to 500 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

10
10
10
10
7
7
7
7
7
7
7
5
5
5
5

4.8
4.8
6
6.8
14.7
17
12.5
13.5
17.5
21
23
35.5
42
42
46

5)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

6)

Not possible for types of construction IM B6, IM B7, IM B8 or IM V6.

7)

The Second shaft extension option, order code K16 is not possible.

8)

Not possible for type of construction IM V3.

Siemens D 81.1 2007

4/39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45

0.11
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
17.3
21.3
24.5
33.5
41.5
51

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L
225 M

2830
2800
2820
2830
2740
2800
2855
2845
2860
2880
2890
2905
2925
2930
2940
2930
2940
2940
2945
2945
2960

0.3
0.41
0.61
0.84
1.3
1.9
2.5
3.7
5
7.3
9.9
13
18
24
36
49
60
71
97
120
145

63
65
64
65
66
71
73
77
79
82
84
86
86.5
88
89.5
90
91
91.7
92.3
92.8
93.6

62
64
63
65
65
70
72
77
80
82
84
86
86.5
88
89.5
90.2
91.2
91.7
92.3
92.8
93.6

0.81
0.83
0.79
0.80
0.82
0.82
0.86
0.87
0.85
0.85
0.85
0.86
0.89
0.89
0.88
0.9
0.91
0.88
0.89
0.89
0.89

0.26
0.32
0.51
0.69
1
1.36
1.73
2.4
3.25
4.55
6.1
7.8
10.4
13.8
20
26.5
32
39.5 1)
53
65 1)
78 1)

1LA7 050-2AA
1LA7 053-2AA
1LA7 060-2AA
1LA7 063-2AA
1LA7 070-2AA
1LA7 073-2AA
1LA7 080-2AA
1LA7 083-2AA
1LA7 090-2AA
1LA7 096-2AA
1LA7 106-2AA
1LA7 113-2AA
1LA7 130-2AA
1LA7 131-2AA
1LA7 163-2AA
1LA7 164-2AA
1LA7 166-2AA
1LA5 183-2AA
1LA5 206-2AA
1LA5 207-2AA
1LA5 223-2AA

3
3
3.5
4.1
5
6
9
11
12.9
15.7
22
29
39
48
68
77
86
113
159
179
209

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200
225

1LA7

1LA5

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/40

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

41
41
49
49
52
52
56
56
62
62
62
63
68
68
70
70
70
70
71
71
71

52
52
60
60
63
63
67
67
74
74
74
75
80
80
82
82
82
83
84
84
84

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA7 050-2AA
1LA7 053-2AA
1LA7 060-2AA
1LA7 063-2AA
1LA7 070-2AA
1LA7 073-2AA
1LA7 080-2AA
1LA7 083-2AA
1LA7 090-2AA
1LA7 096-2AA
1LA7 106-2AA
1LA7 113-2AA
1LA7 130-2AA
1LA7 131-2AA
1LA7 163-2AA
1LA7 164-2AA
1LA7 166-2AA
1LA5 183-2AA
1LA5 206-2AA
1LA5 207-2AA
1LA5 223-2AA

2
2.1
2
2
2.3
2.5
2.3
2.6
2.4
2.8
2.8
2.6
2
2.3
2.1
2.2
2.4
2.5
2.4
2.4
2.8

3.7
3.7
3.7
4
3.5
4.3
5.6
6.1
5.5
6.3
6.8
7.2
5.9
6.9
6.5
6.6
7
6.9
7.2
7.7
7.7

2.3
2.4
2.2
2.2
2.3
2.6
2.4
2.7
2.7
3.1
3
2.9
2.8
3
2.9
3
3.1
3.2
2.8
2.8
3.4

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.00015
0.00015
0.00018
0.00022
0.00029
0.00041
0.00079
0.001
0.0014
0.0018
0.0035
0.0059
0.015
0.019
0.034
0.043
0.051
0.077
0.14
0.16
0.2

Order No. supplements


Motor type

1LA7 05 . - . . .
1LA7 06 . - . . .
1LA7 07 . - . . .
1LA7 08 . - . . .
1LA7 09 . - . . .
1LA7 10 . - . . .
1LA7 11 . - . . .
1LA7 13 . - . . .
1LA7 16 . - . . .
1LA5 18 . - . . .
1LA5 20 . - . . .
1LA5 22 . - . . .

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B35 IM B14, IM B34
1)
IM V3 with protecIM V19
(see Introduc- IM V6
1)
1)
tive cover
tion for outputs
1) 2) 3)
at 60 Hz)
1
6
3
5
1
6
0
1
4
6
2
7

4)

4)

4)

60 Hz

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

1LA5 183-... to 1LA5 223-... motors (motor series 1LA5, frame size 180 M
to 225 M) can be supplied with two additional eyebolts; specify supplement Z and order code K32 .

3)

The Second shaft extension option, order code K16 is not possible.

4)

Type of construction IM V3 is only possible using type of construction


code 9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/41

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45

0.07
0.11
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
17.3
21.3
25.3
34.5
42.5
52

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M

1350
1350
1350
1350
1350
1370
1395
1395
1415
1420
1420
1420
1440
1455
1455
1460
1460
1460
1460
1465
1470
1470

0.42
0.64
0.85
1.3
1.8
2.6
3.8
5.1
7.4
10
15
20
27
36
49
72
98
121
144
196
240
292

56
58
55
59
60
65
70
72
77
79
82
83
85
86
87
88.5
90
90.5
91.2
91.8
92.9
93.4

55
57
54
60
60
65
70
72
77
79
82.5
83.5
85.5
86
87.5
89
90.2
90.5
91.2
91.8
92.9
93.4

0.77
0.77
0.75
0.76
0.78
0.78
0.80
0.8
0.81
0.81
0.82
0.82
0.83
0.81
0.82
0.84
0.84
0.83
0.84
0.86
0.87
0.87

0.2
0.29
0.42
0.58
0.77
1.06
1.93
1.91
2.55
3.4
4.7
6.4
8.2
11.4
15.2
21.5
28.5
35.5 1)
41.5 1)
55
66 1)
80 1)

1LA7 050-4AB
1LA7 053-4AB
1LA7 060-4AB
1LA7 063-4AB
1LA7 070-4AB
1LA7 073-4AB
1LA7 080-4AA
1LA7 083-4AA
1LA7 090-4AA
1LA7 096-4AA
1LA7 106-4AA
1LA7 107-4AA
1LA7 113-4AA
1LA7 130-4AA
1LA7 133-4AA
1LA7 163-4AA
1LA7 166-4AA
1LA5 183-4AA
1LA5 186-4AA
1LA5 207-4AA
1LA5 220-4AA
1LA5 223-4AA

3
3
3.5
4.1
4.8
6
9
10
13
15.6
21
24
31
41
49
73
85
113
123
157
206
232

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200
225

1LA7

1LA5

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/42

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

42
42
42
42
44
44
47
47
50
50
56
56
53
62
62
66
66
63
63
65
65
65

53
53
53
53
55
55
58
58
62
62
68
68
65
74
74
78
78
76
76
78
78
78

LWA
dB(A)

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA7 050-4AB
1LA7 053-4AB
1LA7 060-4AB
1LA7 063-4AB
1LA7 070-4AB
1LA7 073-4AB
1LA7 080-4AA
1LA7 083-4AA
1LA7 090-4AA
1LA7 096-4AA
1LA7 106-4AA
1LA7 107-4AA
1LA7 113-4AA
1LA7 130-4AA
1LA7 133-4AA
1LA7 163-4AA
1LA7 166-4AA
1LA5 183-4AA
1LA5 186-4AA
1LA5 207-4AA
1LA5 220-4AA
1LA5 223-4AA

1.9
1.9
1.9
1.9
1.9
1.9
2.2
2.3
2.3
2.4
2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.3
2.3
2.6
2.8
2.8

2.6
2.6
2.8
3
3
3.3
3.9
4.2
4.6
5.3
5.6
5.6
6
6.3
6.7
6.2
6.5
7.5
7.5
7
7
7.7

1.9
1.9
2
1.9
1.9
2.1
2.2
2.3
2.4
2.6
2.8
3
3
3.1
3.2
2.7
3
3
3
3.2
3.2
3.3

13
13
13
13
13
13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.00027
0.00027
0.00029
0.00037
0.00052
0.00077
0.0014
0.0017
0.0024
0.0033
0.0047
0.0055
0.012
0.018
0.023
0.043
0.055
0.13
0.15
0.24
0.32
0.36

Order No. supplements


Motor type

1LA7 05 . - . . .
1LA7 06 . - . . .
1LA7 07 . - . . .
1LA7 08 . - . . .
1LA7 09 . - . . .
1LA7 10 . - . . .
1LA7 11 . - . . .
1LA7 13 . - . . .
1LA7 16 . - . . .
1LA5 18 . - . . .
1LA5 20 . - . . .
1LA5 22 . - . . .

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B35 IM B14, IM B34
1)
IM V3 with protecIM V19
(see Introduc- IM V6
1)
1)
tive cover
tion for outputs
1) 2) 3)
at 60 Hz)
1
6
3
5
1
6
0
1
4
6
2
7

4)

4)

4)

60 Hz

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

1LA5 183-... to 1LA5 223-... motors (motor series 1LA5, frame size 180 M
to 225 M) can be supplied with two additional eyebolts; specify supplement Z and order code K32.

3)

The Second shaft extension option, order code K16 is not possible.

4)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/43

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power
factor
at 50 Hz
4/4-load

Rated
current
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

0.09
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30

0.1
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
12.6
18
22
26.5
36

63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M

850
850
830
920
910
915
915
925
940
950
950
950
960
960
970
975
975
978

1
2
2.8
3.8
5.8
7.8
11
15
22
30
40
55
75
109
148
181
215
293

45
53
60
62
67
69
72
74
78
79
80.5
83
86
87.5
89.5
90.2
90.8
91.8

41.5
54.5
58.5
60.5
66.5
69
72
74
78.5
79.5
80.5
83
86
87.5
89.5
90.2
90.8
91.8

0.66
0.68
0.76
0.72
0.74
0.76
0.77
0.75
0.78
0.76
0.76
0.76
0.74
0.74
0.77
0.77
0.77
0.77

0.44
0.72
0.79
1.2
1.6
2.05
2.85
3.9
5.2
7.2
9.4
12.6
17
24.5
31.5
38.5
45.5
61 1)

1LA7 063-6AB
1LA7 070-6AA
1LA7 073-6AA
1LA7 080-6AA
1LA7 083-6AA
1LA7 090-6AA
1LA7 096-6AA
1LA7 106-6AA
1LA7 113-6AA
1LA7 130-6AA
1LA7 133-6AA
1LA7 134-6AA
1LA7 163-6AA
1LA7 166-6AA
1LA5 186-6AA
1LA5 206-6AA
1LA5 207-6AA
1LA5 223-6AA

4.1
5
6.3
9
10
12.5
15.7
21
26
38
44
52
74
95
126
161
183
214

Special versions according to ATEX


Motor type

Frame
size
63
71
80
90
100
112
132
160
180
200
225

1LA7

1LA5

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/44

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

39
39
39
40
40
43
43
47
52
63
63
63
66
66
66
66
66
66

50
50
50
51
51
55
55
59
64
75
75
75
78
78
78
78
78
78

LWA
dB(A)

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA7 063-6AB
1LA7 070-6AA
1LA7 073-6AA
1LA7 080-6AA
1LA7 083-6AA
1LA7 090-6AA
1LA7 096-6AA
1LA7 106-6AA
1LA7 113-6AA
1LA7 130-6AA
1LA7 133-6AA
1LA7 134-6AA
1LA7 163-6AA
1LA7 166-6AA
1LA5 186-6AA
1LA5 206-6AA
1LA5 207-6AA
1LA5 223-6AA

1.8
2.1
2.2
1.9
2.1
2.2
2.3
2.3
2.2
1.9
2.1
2.3
2.1
2.3
2
2.7
2.8
2.8

2
2.3
2.7
3.1
3.4
3.7
3.8
4
4.6
4.2
4.5
5
4.6
4.8
5.2
5.5
5.5
5.7

1.9
1.9
2
2.1
2.2
2.2
2.3
2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.4
2.8
2.9
2.9

13
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.00037
0.00055
0.0008
0.0014
0.0017
0.0024
0.0033
0.0047
0.0091
0.015
0.019
0.025
0.044
0.063
0.15
0.24
0.28
0.36

Order No. supplements


Motor type

1LA7 06 . - . . .
1LA7 07 . - . . .
1LA7 08 . - . . .
1LA7 09 . - . . .
1LA7 10 . - . . .
1LA7 11 . - . . .
1LA7 13 . - . . .
1LA7 16 . - . . .
1LA5 18 . - . . .
1LA5 20 . - . . .
1LA5 22 . - . . .

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B35 IM B14, IM B34
1)
IM V3 with protecIM V19
(see Introduc- IM V6
1)
1)
tive cover
tion for out1) 2) 3)
puts at 60 Hz)
1
6
3
5
1
6
0
1
4
6
2
7

4)

4)

4)

60 Hz

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

1LA5 183-... to 1LA5 223-... motors (motor series 1LA5, frame size 180 M
to 225 M) can be supplied with two additional eyebolts; specify supplement Z and order code K32.

3)

The Second shaft extension option, order code K16 is not possible.

4)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/45

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power
factor
at 50 Hz
4/4-load

Rated
current
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22

0.1
0.14
0.21
0.29
0.43
0.63
0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
13.2
18
22
26.5

71 M
71 M
80 M
80 M
90 S
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M

630
645
675
685
675
675
680
680
705
700
700
715
710
715
725
725
725
725

1.4
1.8
2.5
3.5
5.2
7.8
11
15
20
30
41
53
74
100
145
198
244
290

53
53
51
55
63
66
66
72
74
75
77
80
83.5
85.5
87
87.5
89.2
90.6

54.5
49.5
49.5
50.5
62
65
65
72
74
75
77.5
80
83.5
85.5
87
87.5
89.2
90.6

0.68
0.64
0.68
0.64
0.75
0.76
0.76
0.76
0.76
0.74
0.74
0.72
0.73
0.72
0.75
0.78
0.79
0.79

0.36
0.51
0.75
1.02
1.14
1.58
2.15
2.9
3.85
5.7
7.6
10
13
17.6
24.5
31.5
38
44.5

1LA7 070-8AB
1LA7 073-8AB
1LA7 080-8AB
1LA7 083-8AB
1LA7 090-8AB
1LA7 096-8AB
1LA7 106-8AB
1LA7 107-8AB
1LA7 113-8AB
1LA7 130-8AB
1LA7 133-8AB
1LA7 163-8AB
1LA7 164-8AB
1LA7 166-8AB
1LA5 186-8AB
1LA5 207-8AB
1LA5 220-8AB
1LA5 223-8AB

6.3
6.3
9
10
10.5
13.2
19
22
24
38
44
64
74
94
128
176
184
214

Special versions according to ATEX


Motor type

Frame
size
71
80
90
100
112
132
160
180
200
225

1LA7

1LA5

1)

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/46

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA7/1LA5

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

36
36
41
41
41
41
45
45
49
53
53
63
63
63
60
58
58
58

47
47
52
52
53
53
57
57
61
65
65
75
75
75
73
71
71
71

LWA
dB(A)

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA7 070-8AB
1LA7 073-8AB
1LA7 080-8AB
1LA7 083-8AB
1LA7 090-8AB
1LA7 096-8AB
1LA7 106-8AB
1LA7 107-8AB
1LA7 113-8AB
1LA7 130-8AB
1LA7 133-8AB
1LA7 163-8AB
1LA7 164-8AB
1LA7 166-8AB
1LA5 186-8AB
1LA5 207-8AB
1LA5 220-8AB
1LA5 223-8AB

1.9
2.2
1.7
2
1.6
1.7
1.6
1.8
1.8
1.9
2.1
2.2
2.3
2.7
2
2.1
2.1
2.2

2.2
2.2
2.3
2.6
2.9
3
3
3.3
3.7
3.9
4.1
4.5
4.7
5.3
5
5
4.5
4.8

1.7
2
1.9
2.2
1.8
1.9
1.9
2.1
2.1
2.3
2.4
2.6
2.7
3
2.2
2.2
2.2
2.3

13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13

0.0008
0.0008
0.0014
0.0017
0.0023
0.0031
0.0051
0.0063
0.013
0.014
0.019
0.036
0.046
0.064
0.21
0.37
0.37
0.45

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B35 IM B14, IM B34
1)
IM V3 with
IM V19
(see Introduc- IM V6
1)
1)
protective
tion for outputs
1) 2) 3)
cover
at 60 Hz)
1

1LA7 07 . - . . .
1LA7 08 . - . . .
1LA7 09 . - . . .
1LA7 10 . - . . .
1LA7 11 . - . . .
1LA7 13 . - . . .
1LA7 16 . - . . .
1LA5 18 . - . . .
1LA5 20 . - . . .
1LA5 22 . - . . .

60 Hz

4)
4)
4)

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

1LA5 183-... to 1LA5 223-... motors (motor series 1LA5, frame size 180 M
to 225 M) can be supplied with two additional eyebolts; specify supplement Z and order code K32.

3)

The Second shaft extension option, order code K16 is not possible.

4)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/47

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data


Rated output
at
50 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 050-2KA
1LA9 053-2KA
1LA9 060-2KA
1LA9 063-2KA
1LA9 070-2KA
1LA9 073-2KA
1LA9 080-2KA
1LA9 083-2KA
1LA9 090-2KA
1LA9 096-2KA
1LA9 106-2KA
1LA9 113-2KA
1LA9 130-2KA
1LA9 131-2KA
1LA9 163-2KA
1LA9 164-2KA
1LA9 166-2KA
1LA9 183-2WA
1LA9 206-2WA
1LA9 207-2WA

3
3.8
4.1
5.1
6
7.2
9.8
12.3
15
18.6
24
35
43
56
73
82
102
131
185
214

2-pole, 3000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency

0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L

2830
2830
2840
2840
2840
2835
2870
2860
2890
2890
2890
2905
2930
2930
2945
2945
2940
2945
2950
2950

0.3
0.4
0.61
0.84
1.2
1.9
2.5
3.7
5
7.3
9.9
13
18
24
36
49
60
71
97
120

70
70
70
72
74
75
80
84
85
86.5
87
88.5
89.5
90.5
91
91.5
92.3
93
93.5
94

68
70
70
70
74
75
80
84
85
86.5
87
88.5
89.5
90.5
91
91.5
92.5
93.2
93.5
94.1

0.76
0.81
0.78
0.8
0.77
0.75
0.82
0.89
0.87
0.87
0.88
0.89
0.9
0.92
0.9
0.9
0.92
0.89
0.89
0.89

0.24
0.31
0.48
0.63
0.94
1.42
1.66
2.1
2.95
4.2
5.7
7.3
9.9
13
19.4
26.5
31.5
38.5 1)
52
64 1)

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 60 Hz according to EPACT,


see Pages 4/54 to 4/59.

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/48

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 50 Hz

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

0.00015
0.0002
0.00022
0.00026
0.00041
0.0005
0.001
0.0013
0.0018
0.0022
0.0044
0.0077
0.019
0.024
0.044
0.051
0.065
0.09
0.16
0.2

41
41
49
49
52
52
56
56
60
60
62
63
68
68
70
70
70
70
71
71

52
52
60
60
63
63
67
67
72
72
74
75
80
80
82
82
82
83
84
84

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LA9 050-2KA
1LA9 053-2KA
1LA9 060-2KA
1LA9 063-2KA
1LA9 070-2KA
1LA9 073-2KA
1LA9 080-2KA
1LA9 083-2KA
1LA9 090-2KA
1LA9 096-2KA
1LA9 106-2KA
1LA9 113-2KA
1LA9 130-2KA
1LA9 131-2KA
1LA9 163-2KA
1LA9 164-2KA
1LA9 166-2KA
1LA9 183-2WA
1LA9 206-2WA
1LA9 207-2WA

3.6
3.2
2.8
2.5
3.3
3.6
4.4
3.8
4.1
4.1
3.4
2.8
2.7
2.8
2.5
2.5
2.4
2.6
2.5
2.7

4.5
4.3
4.8
4.9
6.5
6.3
8.3
7
7
7
7
7
7
7
7
7
7
7.2
7
7

3
2.8
3.1
2.5
3.1
2.9
3.2
3.2
3.5
3.5
3.2
3.2
3.2
3.1
3.1
3.1
3.1
3.3
3.2
3.3

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1LA9 05 . - . . .
1LA9 06 . - . . .
1LA9 07 . - . . .
1LA9 08 . - . . .
1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 1)
IM V3 1) with protective
cover 1) 2)
0
1
4
6

3)

3)

With standard flange With special


flange
IM B14, IM B34
IM B14,
IM V19 1)
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/49

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Rated output
at
50 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 050-4KA
1LA9 053-4KA
1LA9 060-4KA
1LA9 063-4KA
1LA9 070-4KA
1LA9 073-4KA
1LA9 080-4KA
1LA9 083-4KA
1LA9 090-4KA
1LA9 096-4KA
1LA9 106-4KA
1LA9 107-4KA
1LA9 113-4KA
1LA9 130-4KA
1LA9 133-4KA
1LA9 163-4KA
1LA9 166-4KA
1LA9 183-4WA
1LA9 186-4WA
1LA9 207-4WA

3
3.8
4.1
5.1
6
7.2
9.8
12.3
15
18
25
30
37
45
60
81
107
126
146
199

4-pole, 1500 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency

0.06
0.09
0.12
0.18
0.25
0.37
0.55
0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L

1380
1390
1395
1395
1410
1385
1410
1400
1440
1440
1435
1435
1440
1455
1455
1460
1460
1465
1465
1465

0.42
0.62
0.82
1.3
1.7
2.6
3.7
5.1
7.3
9.9
15
20
27
36
49
72
98
121
143
196

61
62
66
65
70
71
77
81
84
85
86.5
87.5
88.5
89.5
90.3
91.5
92
92.5
93
93.5

61
62
66
65
70
71
77
81
84
85
86.5
87.7
89
89.5
90.5
92
92.3
93
93.4
94

0.66
0.68
0.65
0.68
0.64
0.73
0.78
0.75
0.77
0.77
0.82
0.81
0.81
0.84
0.84
0.85
0.86
0.84
0.84
0.87

0.22
0.31
0.41
0.59
0.81
1.04
1.32
1.78
2.45
3.3
4.5
6.1
8.1
10.6
14.2
20.5
27.5
34.5 1)
40.5 1)
53

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 60 Hz according to EPACT,


see Pages 4/54 to 4/59.

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/50

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 50 Hz

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

0.00027
0.00035
0.00037
0.00045
0.00076
0.00095
0.0017
0.0024
0.0033
0.004
0.0062
0.0077
0.014
0.023
0.029
0.055
0.072
0.15
0.19
0.32

42
42
42
42
44
44
47
47
48
48
53
53
53
62
62
66
66
63
63
65

53
53
53
53
55
55
58
58
60
60
65
65
65
74
74
78
78
76
76
78

LWA
dB(A)

4-pole, 1500 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LA9 050-4KA
1LA9 053-4KA
1LA9 060-4KA
1LA9 063-4KA
1LA9 070-4KA
1LA9 073-4KA
1LA9 080-4KA
1LA9 083-4KA
1LA9 090-4KA
1LA9 096-4KA
1LA9 106-4KA
1LA9 107-4KA
1LA9 113-4KA
1LA9 130-4KA
1LA9 133-4KA
1LA9 163-4KA
1LA9 166-4KA
1LA9 183-4WA
1LA9 186-4WA
1LA9 207-4WA

2.7
2.8
2.7
3
3.6
3.3
3.4
4
3.1
3.6
3.4
3.8
3.2
3.2
3.4
2.6
2.8
2.8
3.1
3

3.1
3.2
3.5
3.6
4.3
4.2
5.6
5.8
6.4
6.7
7
7
6.9
7
7
6.9
7
7
7.3
7

2.8
2.8
2.6
2.5
3.1
3
2.9
3.5
3.2
3.4
3.6
3.9
3.2
3.6
3.6
3.2
3.3
3.2
3.4
3.2

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1LA9 05 . - . . .
1LA9 06 . - . . .
1LA9 07 . - . . .
1LA9 08 . - . . .
1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 1)
IM V3 1) with protective
cover 1) 2)
0
1
4
6

3)

3)

With standard flange With special


flange
IM B14, IM B34
IM B14,
IM V19 1)
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/51

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Rated output
at 50 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 090-6KA
1LA9 096-6KA
1LA9 106-6KA
1LA9 113-6KA
1LA9 133-6KA
1LA9 134-6KA
1LA9 163-6KA
1LA9 166-6KA
1LA9 186-6WA
1LA9 206-6WA
1LA9 207-6WA

15.7
19
25
37
49
64
98
105
144
186
217

6-pole, 1000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency

0.75
1.1
1.5
2.2
4
5.5
7.5
11
15
18.5
22

90 S
90 L
100 L
112 M
132 M
132 M
160 M
160 L
180 L
200 L
200 L

925
940
935
955
950
960
965
960
970
975
975

7.7
11
15
22
40
55
74
109
148
181
215

75.5
82
85
84
84
86
88
88.5
91
91
91.5

75.5
82
85
84
84
86
88
88.5
91
91
91.5

0.72
0.7
0.73
0.7
0.81
0.77
0.72
0.78
0.75
0.77
0.77

2
2.75
3.6
5.4
8.5
12
17
23
31.5
38
45

Special versions according to ATEX


Motor type

Frame
size
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 60 Hz according to EPACT,


see Pages 4/54 to 4/59.

1)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/52

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Measuring
surface sound
pressure level
at 50 Hz

Sound pressure
level at 50 Hz

J
kgm

LpfA
dB(A)

LWA
dB(A)

0.0033
0.005
0.0065
0.014
0.025
0.03
0.063
0.0072
0.19
0.28
0.36

43
43
47
52
63
63
66
66
66
66
66

55
55
59
64
75
75
78
78
78
78
78

6-pole, 1000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LA9 090-6KA
1LA9 096-6KA
1LA9 106-6KA
1LA9 113-6KA
1LA9 133-6KA
1LA9 134-6KA
1LA9 163-6KA
1LA9 166-6KA
1LA9 186-6WA
1LA9 206-6WA
1LA9 207-6WA

3.
3.7
3.5
2.9
3
3.7
2.4
3.1
2.2
2.8
2.8

4.4
5.7
6.2
6.2
6.3
7.3
5.5
6.9
6.5
6.2
6.2

2.5
3.2
3.4
3
2.7
3.6
2.5
3.2
2.5
2.5
2.5

16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5,
IM V1
IM B35
IM V6 1)
IM V3 1) with protective
cover 1) 2)
0
1
4
6

3)

3)

With standard flange With special


flange
IM B14, IM B34
IM B14,
1)
IM V19
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/53

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power factor Rated


at 60 Hz
current
4/4-load
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 050-2KA
1LA9 053-2KA
1LA9 060-2KA
1LA9 063-2KA
1LA9 070-2KA
1LA9 073-2KA
1LA9 080-2KA
1LA9 083-2KA
1LA9 090-2KA
1LA9 096-2KA
1LA9 106-2KA
1LA9 113-2KA
1LA9 130-2KA
1LA9 131-2KA
1LA9 163-2KA
1LA9 164-2KA
1LA9 166-2KA
1LA9 183-2WA
1LA9 206-2WA
1LA9 207-2WA

3
3.8
4.1
5.1
6
7.2
9.8
12.3
15
18.6
24
35
43
56
73
82
102
131
185
214

2-pole, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

0.12
0.16
0.25
0.33
0.5
0.75
1
1.5
2
3
4
5
7.5
10
15
20
25
30
40
50

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L

3440
3440
3440
3460
3445
3445
3485
3480
3510
3510
3510
3540
3540
3540
3555
3555
3550
3545
3555
3555

0.25
0.33
0.53
0.69
1
1.6
2
3.1
4.1
6.1
8.1
10
15
20
30
40
50
60
80
100

No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

70
71
71
72
72
73
75.5
82.5
84
85.5
86.5
87.5
88.5
89.5
90.2
90.2
91
91
91.7
92.4

0.74
0.76
0.79
0.76
0.75
0.73
0.82
0.88
0.86
0.85
0.87
0.88
0.9
0.92
0.9
0.9
0.92
0.86
0.88
0.88

0.23
0.28
0.4
0.56
0.86
1.3
1.52
1.9
2.6
3.8
5
6
8.7
11.4
17
23.2
27.7
36
46.5
57

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/48 to 4/53.

1)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/54

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 60 Hz

J
kgm

Measuring
surface sound
pressure level
at 60 Hz
LpfA
dB(A)

0.00015
0.0002
0.00022
0.00026
0.00041
0.0005
0.001
0.0013
0.0018
0.0022
0.0044
0.0077
0.019
0.024
0.044
0.051
0.065
0.09
0.16
0.2

45
45
53
53
56
56
60
60
64
64
66
67
72
72
74
74
74
74
75
75

56
56
64
64
67
67
71
71
76
76
78
79
84
84
86
86
86
87
88
88

LWA
dB(A)

2-pole, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT
1LA9 050-2KA
1LA9 053-2KA
1LA9 060-2KA
1LA9 063-2KA
1LA9 070-2KA
1LA9 073-2KA
1LA9 080-2KA
1LA9 083-2KA
1LA9 090-2KA
1LA9 096-2KA
1LA9 106-2KA
1LA9 113-2KA
1LA9 130-2KA
1LA9 131-2KA
1LA9 163-2KA
1LA9 164-2KA
1LA9 166-2KA
1LA9 183-2WA
1LA9 206-2WA
1LA9 207-2WA

3.6
3.2
2.8
2.5
3.3
3.6
4.4
3.8
4.1
4.1
3.4
2.8
2.7
2.8
2.5
2.5
2.4
2.6
2.5
2.7

5.5
5.4
4.9
5
7.5
7.2
9.6
8.6
8.6
8.5
8.6
9.2
8.5
8.3
8.5
8.5
8.5
8.6
8.4
8.4

3.8
3.4
3.3
2.7
3.4
3.7
4.4
3.2
4.1
5.1
3.7
4
3.8
3.7
3.7
3.7
3.5
3.5
3.6
3.7

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position:
Voltage code
60 Hz
460 VY
460 V
(see Introduction
for outputs at 60 Hz)
1
6

1LA9 05 . - . . .
1LA9 06 . - . . .
1LA9 07 . - . . .
1LA9 08 . - . . .
1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without flange With flange
IM B3/6/7/8,
IM B5, IM V3 IM V1 with
1)
IM V6 1)
protective
cover 1) 2)
0

3)
3)

IM B35

With standard flange


IM B14,
IM B34
IM V19 1)

With special flange


IM B14, IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction


code 9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/55

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power factor Rated


at 60 Hz
current
4/4-load
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 050-4KA
1LA9 053-4KA
1LA9 060-4KA
1LA9 063-4KA
1LA9 070-4KA
1LA9 073-4KA
1LA9 080-4KA
1LA9 083-4KA
1LA9 090-4KA
1LA9 096-4KA
1LA9 106-4KA
1LA9 107-4KA
1LA9 113-4KA
1LA9 130-4KA
1LA9 133-4KA
1LA9 163-4KA
1LA9 166-4KA
1LA9 183-4WA
1LA9 186-4WA
1LA9 207-4WA

3
3.8
4.1
5.1
6
7.2
9.8
12.3
15
18
25
30
37
45
60
81
107
126
146
199

4-pole, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

0.08
0.12
0.16
0.25
0.33
0.5
0.75
1
1.5
2
3
4
5
7.5
10
15
20
25
30
40

56 M
56 M
63 M
63 M
71 M
71 M
80 M
80 M
90 S
90 L
100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L

1715
1725
1710
1705
1730
1725
1725
1720
1755
1775
1750
1750
1755
1760
1760
1765
1765
1770
1770
1770

0.33
0.5
0.66
1.1
1.4
2.1
3.1
4.1
6.1
14
12
16
20
30
40
61
81
101
121
161

No
No
No
No
No
No
No
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

63
64
68
66
69
70
75.5
82.5
84
84
87.5
87.5
87.5
89.5
89.5
91
91
92.4
92.4
93

0.65
0.6
0.6
0.63
0.6
0.68
0.74
0.75
0.76
0.76
0.79
0.79
0.79
0.81
0.82
0.85
0.85
0.83
0.83
0.86

0.18
0.29
0.37
0.54
0.76
0.98
1.24
1.59
2.15
2.95
4
5.5
6.7
9.5
12.8
17.9
24.5
30.5
36
47

Special versions according to ATEX


Motor type

Frame
size
56
63
71
80
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/48 to 4/53.

1)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/56

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 60 Hz

J
kgm

Measuring
surface sound
pressure level
at 60 Hz
LpfA
dB(A)

0.00027
0.00035
0.00037
0.00045
0.00076
0.00095
0.0017
0.0024
0.0033
0.004
0.0062
0.0077
0.014
0.023
0.029
0.055
0.072
0.15
0.19
0.32

46
46
46
46
48
48
51
51
52
52
57
57
57
66
66
70
70
67
67
69

57
57
57
57
59
59
62
62
64
64
69
69
69
78
78
82
82
80
80
82

LWA
dB(A)

4-pole, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT
1LA9 050-4KA
1LA9 053-4KA
1LA9 060-4KA
1LA9 063-4KA
1LA9 070-4KA
1LA9 073-4KA
1LA9 080-4KA
1LA9 083-4KA
1LA9 090-4KA
1LA9 096-4KA
1LA9 106-4KA
1LA9 107-4KA
1LA9 113-4KA
1LA9 130-4KA
1LA9 133-4KA
1LA9 163-4KA
1LA9 166-4KA
1LA9 183-4WA
1LA9 186-4WA
1LA9 207-4WA

2.7
2.8
2.7
3
3.6
3.3
3.4
4
3.1
3.6
3.4
3.8
3.2
3.2
3.4
2.6
2.8
2.8
3.1
3

3.4
3.5
3.9
3.6
4.9
4.9
6.8
7.3
7.7
8.1
8.4
8.7
8.6
8.7
8.7
8.1
8.5
8.4
8.8
8.3

3
3
2.8
3.1
3.4
3.4
3.6
3.9
3.9
4.2
4.3
4.6
3.9
4.1
4.1
3.2
3.5
3.6
3.9
3.6

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position:
Voltage code
60 Hz
460 VY
460 V
(see Introduction
for outputs at 60 Hz)
1
6

1LA9 05 . - . . .
1LA9 06 . - . . .
1LA9 07 . - . . .
1LA9 08 . - . . .
1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without flange With flange
IM B3/6/7/8,
IM B5, IM V3 IM V1 with
1)
IM V6 1)
protective
cover 1) 2)
0

3)
3)

IM B35

With standard flange


IM B14,
IM B34
IM V19 1)

With special flange


IM B14, IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/57

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power factor Rated


at 60 Hz
current
4/4-load
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LA9 090-6KA
1LA9 096-6KA
1LA9 106-6KA
1LA9 113-6KA
1LA9 133-6KA
1LA9 134-6KA
1LA9 163-6KA
1LA9 166-6KA
1LA9 186-6WA
1LA9 206-6WA
1LA9 207-6WA

15.7
19
25
37
49
64
98
105
144
186
217

6-pole, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

1
1.5
2
3
5
7.5
10
15
20
25
30

90 S
90 L
100 L
112 M
132 M
132 M
160 M
160 L
180 L
200 L
200 L

1140
1150
1150
1160
1160
1160
1165
1165
1175
1175
1175

6.2
9.3
12
18
31
46
61
92
121
152
182

Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

80
85.5
86.5
87.5
87.5
89.5
89.5
90.2
90.2
91.7
91.7

0.66
0.64
0.7
0.66
0.77
0.73
0.7
0.77
0.75
0.75
0.75

1.78
2.55
3.1
4.8
6.9
10.6
15
19
28
34
40

Special versions according to ATEX


Motor type

Frame
size
90
100
112
132
160
180
200

1LA9

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/48 to 4/53.

1)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/58

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Aluminum series 1LA9

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Measuring
surface sound
pressure level
at 60 Hz

Sound pressure
level at 60 Hz

J
kgm

LpfA
dB(A)

LWA
dB(A)

0.0033
0.005
0.0065
0.014
0.025
0.03
0.063
0.0072
0.19
0.28
0.36

47
47
51
56
67
67
70
70
70
70
70

59
59
63
68
79
79
82
82
82
82
82

6-pole, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT
1LA9 090-6KA
1LA9 096-6KA
1LA9 106-6KA
1LA9 113-6KA
1LA9 133-6KA
1LA9 134-6KA
1LA9 163-6KA
1LA9 166-6KA
1LA9 186-6WA
1LA9 206-6WA
1LA9 207-6WA

3
3.7
3.5
2.9
3
3.7
2.4
3.1
2.8
2.8
2.8

5.6
6.4
7.2
7.5
7.9
8.4
6.4
8.3
7.1
7.1
7.2

3
3.7
3.8
3.7
3.6
4.3
2.8
3.8
2.8
2.8
2.8

16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

Penultimate position:
Voltage code
60 Hz
460 VY
460 V
(see Introduction
for outputs at 60 Hz)
1
6

1LA9 09 . - . . .
1LA9 10 . - . . .
1LA9 11 . - . . .
1LA9 13 . - . . .
1LA9 16 . - . . .
1LA9 18 . - . . .
1LA9 20 . - . . .

Final position: Type of construction code


Without flange With flange
IM B3/6/7/8,
IM B5, IM V3 IM V1 with
1)
IM V6 1)
protective
cover 1) 2)
0

3)
3)

IM B35

With standard flange


IM B14,
IM B34
IM V19 1)

With special flange


IM B14, IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

2)

The Second shaft extension option, order code K16 is not possible.

3)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

Siemens D 81.1 2007

4/59

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200

3.45
4.6
6.3
8.6
12.6
17.3
21.3
24.5
33.5
41.5
51
62
84
101
123
148
180
224

100 L
112 M
132 S
132 S
160 M
160 M
160 L
180 M
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

2890
2905
2925
2930
2940
2940
2940
2945
2950
2955
2960
2970
2975
2975
2982
2982
2982
2982

9.9
13
18
24
36
49
60
71
97
120
145
177
241
289
352
423
512
641

84
86
86.5
88
89.5
90
91
91.6
91.8
92.9
93.6
93.6
94.5
95.1
94.6
95.1
95.5
95.9

84
86
86.5
88
89.5
90.2
91.2
91.6
91.9
93.2
93.9
93.8
94.3
95.2
93.8
94.8
95.3
95.8

0.85
0.86
0.89
0.89
0.88
0.9
0.91
0.86
0.88
0.89
0.88
0.88
0.88
0.89
0.88
0.9
0.91
0.92

6.1
7.8
10.4
13.8
20
26.5
32
40.5 1)
54 1)
65 1)
79 1)
96
130 1)
154 1)
190 1)
225 1)
265 2)
325 2)

1LA6 106-2AA
1LA6 113-2AA
1LA6 130-2AA
1LA6 131-2AA
1LA6 163-2AA
1LA6 164-2AA
1LA6 166-2AA
1LG4 183-2AA
1LG4 206-2AA
1LG4 207-2AA
1LG4 223-2AA
1LG4 253-2AB
1LG4 280-2AB
1LG4 283-2AB
1LG4 310-2AB
1LG4 313-2AB
1LG4 316-2AB
1LG4 317-2AB

34
43
53
58
96
105
115
145
205
225
285
375
500
540
720
775
900
1015

Special versions according to ATEX


Motor type

Frame
size
100
112
132
160
180
200
225
250
280
315

1LA6

1LG4

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 3)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4/60

Siemens D 81.1 2007

3)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

62
63
68
68
70
70
70
67
74
73
73
75
74
74
81
80
79
79

74
75
80
80
82
82
82
80
87
86
86
88
87
87
95
94
92
92

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA6 106-2AA
1LA6 113-2AA
1LA6 130-2AA
1LA6 131-2AA
1LA6 163-2AA
1LA6 164-2AA
1LA6 166-2AA
1LG4 183-2AA
1LG4 206-2AA
1LG4 207-2AA
1LG4 223-2AA
1LG4 253-2AB
1LG4 280-2AB
1LG4 283-2AB
1LG4 310-2AB
1LG4 313-2AB
1LG4 316-2AB
1LG4 317-2AB

2.8
2.6
2
2.3
2.1
2.2
2.4
2.5
2.3
2.5
2.4
2.1
2.5
2.6
2.4
2.4
2.4
2.3

6.8
7.2
5.9
6.9
6.5
6.6
7
6.4
6.5
7.2
6.7
6.7
7.5
7.2
7.2
6.9
7
6.7

3
2.9
2.8
3
2.9
3
3.1
3.4
3
3.3
3.1
3.1
3.1
3.1
3.1
3
3
2.9

16
16
16
16
16
16
16
16
16
16
16
13
13
13
13
13
13
13

0.0035
0.0059
0.015
0.019
0.034
0.043
0.051
0.068
0.13
0.15
0.22
0.4
0.72
0.83
1.2
1.4
1.6
2.1

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B 35 IM B14, IM B34
1) 2)
IM V3 With
IM V19
(see Introduc- IM V6
1) 3)
1)
protective
tion for outputs
1) 3) 4)
cover
at 60 Hz)
1

1LA6 10 . - . . .
1LA6 11 . - . . .
1LA6 13 . - . . .
1LA6 16 . - . . .
1LG4 18 . - . . .
1LG4 20 . - . . .
1LG4 22 . - . . .
1LG4 25 . - . . .
1LG4 28 . - . . .
1LG4 310 - . . .
1LG4 313 - . . .
1LG4 316 - . . .
1LG4 317 - . . .

60 Hz

6)

With special flange


IM B14,
IM V19 1)

5)
5)
5)
5)
5)
5)

7)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

3)

1LG4 220-... to 1LG4 318-... motors (motor series 225 S to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one
can be relocated in accordance with IM V1 or IM V3. It is important to note
that stress must not be applied perpendicular to the ring plane.

4)

The Second shaft extension option, order code K16 is not possible.

5)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

7)

2-pole motors in 60 Hz version available on request.

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.
If motors 1LG4 183-... to 1LG4 318-... (motor series 1LG4 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

Siemens D 81.1 2007

4/61

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power
factor
at 50 Hz
4/4-load

Rated
current
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200

2.55
3.45
4.6
6.3
8.6
12.6
17.3
21.3
25.3
34.5
42.5
52
63
86
104
127
152
184
230

100 L
100 L
112 M
132 S
132 M
160 M
160 L
180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

1420
1420
1440
1455
1455
1460
1460
1465
1465
1465
1475
1475
1480
1485
1485
1488
1488
1486
1486

15
20
27
36
49
72
98
121
143
196
240
291
355
482
579
706
847
1028
1285

82
83
85
86
87
88.5
90
90.4
91
91.6
92.2
93.1
93.5
94.2
94.6
94.6
95.2
95.7
95.9

82.5
83.5
85.5
86
87.5
89
90.2
90.8
91.5
92
92.6
93.6
93.8
94.1
94.6
94.6
95.2
95.8
96.2

0.82
0.82
0.83
0.81
0.82
0.84
0.84
0.84
0.84
0.85
0.85
0.86
0.85
0.85
0.86
0.85
0.85
0.86
0.88

4.7
6.4
8.2
11.4
15.2
21.5
28.5
35 1)
41.5 1)
56 1)
68 1)
81 1)
100
136 1)
160 1)
198 1)
235 1)
280 2)
340 2)

1LA6 106-4AA
1LA6 107-4AA
1LA6 113-4AA
1LA6 130-4AA
1LA6 133-4AA
1LA6 163-4AA
1LA6 166-4AA
1LG4 183-4AA
1LG4 186-4AA
1LG4 207-4AA
1LG4 220-4AA
1LG4 223-4AA
1LG4 253-4AA
1LG4 280-4AA
1LG4 283-4AA
1LG4 310-4AA
1LG4 313-4AA
1LG4 316-4AA
1LG4 317-4AA

33
36
45
55
62
100
114
140
155
205
265
300
390
535
580
730
810
955
1060

Special versions according to ATEX


Motor type

Frame
size
100
112
132
160
180
200
225
250
280
315

1LA6

1LG4

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 3)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4/62

Siemens D 81.1 2007

3)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

53
53
53
62
62
66
66
65
65
66
66
66
65
70
68
70
70
70
71

65
65
65
74
74
78
78
78
78
79
79
79
78
83
82
83
83
83
86

LWA
dB(A)

4-pole, 1500 rpm at 50 Hz, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA6 106-4AA
1LA6 107-4AA
1LA6 113-4AA
1LA6 130-4AA
1LA6 133-4AA
1LA6 163-4AA
1LA6 166-4AA
1LG4 183-4AA
1LG4 186-4AA
1LG4 207-4AA
1LG4 220-4AA
1LG4 223-4AA
1LG4 253-4AA
1LG4 280-4AA
1LG4 283-4AA
1LG4 310-4AA
1LG4 313-4AA
1LG4 316-4AA
1LG4 317-4AA

2.5
2.7
2.7
2.5
2.7
2.2
2.6
2.4
2.5
2.5
2.3
2.6
2.4
2.5
2.5
2.5
2.7
2.7
2.6

5.6
5.6
6
6.3
6.7
6.2
6.5
6.7
6.9
6.7
6.7
7.2
6.1
7.1
7.4
6.4
6.8
6.8
6.5

2.8
3
3
3.1
3.2
2.7
3
3.1
3.2
3.4
3.1
3.2
2.8
3
3
2.8
2.9
2.8
2.8

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.0047
0.0055
0.012
0.018
0.023
0.043
0.055
0.099
0.12
0.19
0.37
0.45
0.69
1.2
1.4
1.9
2.3
2.9
3.5

Order No. supplements


Motor type

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B 35 IM B14, IM B34
1) 2)
IM V3 With
IM V19
(see Introduc- IM V6
1) 3)
1)
protective
tion for outputs
1) 3) 4)
cover
at 60 Hz)
1

1LA6 10 . - . . .
1LA6 11 . - . . .
1LA6 13 . - . . .
1LA6 16 . - . . .
1LG4 18 . - . . .
1LG4 20 . - . . .
1LG4 22 . - . . .
1LG4 25 . - . . .
1LG4 28 . - . . .
1LG4 310 - . . .
1LG4 313 - . . .
1LG4 316 - . . .
1LG4 317 - . . .

60 Hz

6)

With special flange


IM B14,
IM V19 1)

5)
5)
5)
5)
5)
5)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

3)

1LG4 220-... to 1LG4 318-... motors (motor series 225 S to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one
can be relocated in accordance with IM V1 or IM V3. It is important to note
that stress must not be applied perpendicular to the ring plane.

4)

The Second shaft extension option, order code K16 is not possible.

5)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.
If motors 1LG4 183-... to 1LG4 318-... (motor series 1LG4 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are
fixed to the wall, it is recommended that the motor feet are supported.

Siemens D 81.1 2007

4/63

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160

1.75
2.55
3.45
4.6
6.3
8.6
12.6
18
22
26.5
36
44.5
54
66
90
108
132
158
192

100 L
112 M
132 S
132 M
132 M
160 M
160 L
180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L

925
940
950
950
950
960
960
965
975
975
978
980
985
985
988
988
988
988
988

15
22
30
40
55
75
109
148
181
215
293
361
436
533
725
870
1063
1276
1547

74
78
79
80.5
83
86
87.5
88.9
89.8
90.3
91.8
92.3
92.4
92.7
93.5
93.9
94.3
94.8
95

74
78.5
79.5
80.5
83
86
87.5
90.3
90.2
91
92.8
93
93.1
93.3
93.7
94.2
94.6
95
95.1

0.75
0.78
0.76
0.76
0.76
0.74
0.74
0.83
0.81
0.81
0.83
0.83
0.85
0.86
0.84
0.84
0.86
0.86
0.86

3.9
5.2
7.2
9.4
12.6
17
24.5
29.5
36.5
43.5
57 1)
70
83
100
138
164 1)
196
235
285 2)

1LA6 106-6AA
1LA6 113-6AA
1LA6 130-6AA
1LA6 133-6AA
1LA6 134-6AA
1LA6 163-6AA
1LA6 166-6AA
1LG4 186-6AA
1LG4 206-6AA
1LG4 207-6AA
1LG4 223-6AA
1LG4 253-6AA
1LG4 280-6AA
1LG4 283-6AA
1LG4 310-6AA
1LG4 313-6AA
1LG4 316-6AA
1LG4 317-6AA
1LG4 318-6AA

33
40
50
57
66
103
122
150
195
205
280
370
475
510
685
750
890
980
1180

Special versions according to ATEX


Motor type

Frame
size
100
112
132
160
180
200
225
250
280
315

1LA6

1LG4

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 3)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

With additional charge


Not possible

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4/64

Siemens D 81.1 2007

3)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

47
52
63
63
63
66
66
56
56
57
60
59
61
61
65
65
62
62
65

59
64
75
75
75
78
78
69
70
70
73
73
74
74
78
78
77
76
78

LWA
dB(A)

6-pole, 1000 rpm at 50 Hz, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA6 106-6AA
1LA6 113-6AA
1LA6 130-6AA
1LA6 133-6AA
1LA6 134-6AA
1LA6 163-6AA
1LA6 166-6AA
1LG4 186-6AA
1LG4 206-6AA
1LG4 207-6AA
1LG4 223-6AA
1LG4 253-6AA
1LG4 280-6AA
1LG4 283-6AA
1LG4 310-6AA
1LG4 313-6AA
1LG4 316-6AA
1LG4 317-6AA
1LG4 318-6AA

2.3
2.2
1.9
2.1
2.3
2.1
2.3
2.3
2.5
2.6
2.7
2.7
2.4
2.5
2.5
2.6
2.5
3.1
3

4
4.6
4.2
4.5
5
4.6
4.8
5.3
5.6
5.7
5.6
6
6.1
6.3
6.5
6.8
6.8
7.3
7.5

2.3
2.5
2.2
2.4
2.6
2.5
2.6
2.5
2.5
2.5
2.5
2.3
2.4
2.5
2.8
2.9
2.9
3
3

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

0.0047
0.0091
0.015
0.019
0.025
0.044
0.063
0.18
0.24
0.29
0.49
0.76
1.1
1.4
2.1
2.5
3.2
4
4.7

Order No. supplements


Motor type

1LA6 10 . - . . .
1LA6 11 . - . . .
1LA6 13 . - . . .
1LA6 16 . - . . .
1LG4 18 . - . . .
1LG4 20 . - . . .
1LG4 22 . - . . .
1LG4 25 . - . . .
1LG4 28 . - . . .
1LG4 310 - . . .
1LG4 313 - . . .
1LG4 316 - . . .
1LG4 317 - . . .
1LG4 318 - . . .

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B 35 IM B14, IM B34
1) 2)
IM V3 With
IM V19
(see Introduc- IM V6
1) 3)
1)
protective
tion for out1) 3) 4)
cover
puts at 60 Hz)
1
6
3
5
1
6
0
1
4
6
2
7

5)

5)

5)

5)

5)

5)

60 Hz

6)

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

3)

1LG4 220-... to 1LG4 318-... motors (motor series 225 S to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one
can be relocated in accordance with IM V1 or IM V3. It is important to note
that stress must not be applied perpendicular to the ring plane.

4)

The Second shaft extension option, order code K16 is not possible.

5)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.
If motors 1LG4 183-... to 1LG4 318-... (motor series 1LG4 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are
fixed to the wall, it is recommended that the motor feet are supported.

Siemens D 81.1 2007

4/65

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Rated output
at
50 Hz
60 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Prated
kW

Trated
Nm

Efficiency
at 50 Hz
3/4-load

Power
factor
at 50 Hz
4/4-load

Rated
current
at 400 V,
50 Hz

rated

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection

0.75
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132

0.86
1.3
1.75
2.55
3.45
4.6
6.3
8.6
13.2
18
22
26.5
36
44.5
54
66
90
108
132
158

100 L
100 L
112 M
132 S
132 M
160 M
160 M
160 L
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L

680
680
705
700
700
715
710
715
725
725
730
730
730
735
735
740
738
738
738
738

11
15
20
30
41
53
74
100
145
198
242
288
392
481
585
710
971
1165
1423
1708

66
72
74
75
77
80
83.5
85.5
87.5
87.7
89.4
89.7
91.4
92
92.4
93
93.3
93.4
94
94.2

65
72
74
75
77.5
80
83.5
85.5
88.3
88.4
90.4
90.7
92.2
92.8
93.3
93.4
94
94
94.4
94.6

0.76
0.76
0.76
0.74
0.74
0.72
0.73
0.72
0.73
0.76
0.78
0.79
0.81
0.81
0.81
0.81
0.83
0.83
0.83
0.83

2.15
2.9
3.85
5.7
7.6
10
13
17.6
25
32.5
38.5
45
58
72
87
106
140
168
205
245

1LA6 106-8AB
1LA6 107-8AB
1LA6 113-8AB
1LA6 130-8AB
1LA6 133-8AB
1LA6 163-8AB
1LA6 164-8AB
1LA6 166-8AB
1LG4 186-8AB
1LG4 207-8AB
1LG4 220-8AB
1LG4 223-8AB
1LG4 253-8AB
1LG4 280-8AB
1LG4 283-8AB
1LG4 310-8AB
1LG4 313-8AB
1LG4 316-8AB
1LG4 317-8AB
1LG4 318-8AB

29
32
39
50
57
91
102
122
150
205
270
290
385
475
515
680
745
865
1020
1100

Special versions according to ATEX


Motor type

Frame
size
100
112
132
160
180
200
225
250
280
315

1LA6

1LG4

1)

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 1)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge


Not possible

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/66

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA6/1LG4

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

Sound pressure
level at 50 Hz

45
45
49
53
53
63
63
63
65
67
57
54
55
55
58
64
64
64
64
64

57
57
61
65
65
75
75
75
78
80
70
67
68
69
71
77
77
77
77
77

LWA
dB(A)

8-pole, 750 rpm at 50 Hz, 900 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection
1LA6 106-8AB
1LA6 107-8AB
1LA6 113-8AB
1LA6 130-8AB
1LA6 133-8AB
1LA6 163-8AB
1LA6 164-8AB
1LA6 166-8AB
1LG4 186-8AB
1LG4 207-8AB
1LG4 220-8AB
1LG4 223-8AB
1LG4 253-8AB
1LG4 280-8AB
1LG4 283-8AB
1LG4 310-8AB
1LG4 313-8AB
1LG4 316-8AB
1LG4 317-8AB
1LG4 318-8AB

1.6
1.8
1.8
1.9
2.1
2.2
2.3
2.7
1.7
2.2
2.3
2.3
2.3
2.2
2.2
2.2
2.2
2.2
2.4
2.5

3
3.3
3.7
3.9
4.1
4.5
4.7
5.3
4.2
4.9
5.5
5.6
5.5
5
5.1
5.8
5.7
5.8
6.1
6.5

1.9
2.1
2.1
2.3
2.4
2.6
2.7
3
2.1
2.6
2.7
2.8
2.6
2.1
2.1
2.6
2.6
2.7
2.8
2.9

13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13

0.0051
0.0063
0.013
0.014
0.019
0.036
0.046
0.064
0.17
0.29
0.48
0.55
0.84
1.1
1.4
2.1
2.5
3.1
3.9
4.5

Order No. supplements


Motor type

1LA6 10 . - . . .
1LA6 11 . - . . .
1LA6 13 . - . . .
1LA6 16 . - . . .
1LG4 18 . - . . .
1LG4 20 . - . . .
1LG4 22 . - . . .
1LG4 25 . - . . .
1LG4 28 . - . . .
1LG4 310 - . . .
1LG4 313 - . . .
1LG4 316 - . . .
1LG4 317 - . . .
1LG4 318 - . . .

Penultimate position: Voltage code


50 Hz

Final position: Type of construction code


Without
With flange
With standard
flange
flange
230 V/400 VY 400 V/690 VY 500 VY 500 V 460 VY 460 V IM B3/6/7/8, IM B5, IM V1
IM B 35 IM B14, IM B34
1) 2)
IM V3 With
IM V19
(see Introduc- IM V6
1) 3)
1)
protective
tion for out1) 3) 4)
cover
puts at 60 Hz)
1
6
3
5
1
6
0
1
4
6
2
7

5)

5)

5)

5)

5)

5)

60 Hz

6)

With special flange


IM B14,
IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

3)

1LG4 220-... to 1LG4 318-... motors (motor series 225 S to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5, whereby one
can be relocated in accordance with IM V1 or IM V3. It is important to note
that stress must not be applied perpendicular to the ring plane.

4)

The Second shaft extension option, order code K16 is not possible.

5)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

2)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.
If motors 1LG4 183-... to 1LG4 318-... (motor series 1LG4 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are
fixed to the wall, it is recommended that the motor feet are supported.

Siemens D 81.1 2007

4/67

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data


Rated output
at
50 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Trated
Nm

Efficiency
at 50 Hz
3/4-load

rated

rated

Power
factor
at 50 Hz
4/4-load
cos rated

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3 type
of construction
approx.
m
kg

38.5 1)
53 1)
64 1)
77 1)
93
128 1)
150 1)
182 1)
220 1)
260 2)
320 2)

1LG6 183-2AA
1LG6 206-2AA
1LG6 207-2AA
1LG6 223-2AA
1LG6 253-2AA
1LG6 280-2AB
1LG6 283-2AB
1LG6 310-2AB
1LG6 313-2AB
1LG6 316-2AB
1LG6 317-2AB

180
225
255
330
420
530
615
790
915
1055
1245

34.5 1)
40.5 1)
55 1)
67 1)
81 1)
96
130 1)
158 1)
190 1)
225 1)
275 2)
340 2)

1LG6 183-4AA
1LG6 186-4AA
1LG6 207-4AA
1LG6 220-4AA
1LG6 223-4AA
1LG6 253-4AA
1LG6 280-4AA
1LG6 283-4AA
1LG6 310-4AA
1LG6 313-4AA
1LG6 316-4AA
1LG6 317-4AA

155
180
225
290
330
460
575
675
810
965
1105
1305

Rated
current
at 400 V,
50 Hz
Irated
A

2-pole, 3000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency

22
30
37
45
55
75
90
110
132
160
200

180 M
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

2955
2960
2960
2965
2975
2975
2978
2982
2982
2982
2982

71
97
119
145
177
241
289
352
423
512
641

94.1
93.5
94.1
94.9
95.3
95.2
95.6
95.8
96
96.4
96.5

94.5
93.4
94
95.1
95.3
95.2
95.7
95.7
95.9
96.4
96.5

0.88
0.88
0.89
0.89
0.9
0.89
0.9
0.91
0.91
0.92
0.93

4-pole, 1500 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
18.5
22
30
37
45
55
75
90
110
132
160
200

180 M
180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L

1470
1470
1470
1480
1480
1485
1485
1486
1488
1488
1490
1490

120
143
195
239
290
354
482
578
706
847
1026
1282

92.6
93.2
93.3
94
94.5
95.1
95.1
95.4
95.9
96.1
96.3
96.4

93.2
93.5
93.4
94.4
94.7
95.3
95.2
95.5
96
96.2
96.4
96.5

0.83
0.84
0.85
0.85
0.85
0.87
0.87
0.86
0.87
0.88
0.88
0.88

Special versions according to ATEX


Motor type

Frame
size
180
200
225
250
280
315

1LG6

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 3)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

With additional charge

The motors can also be used for 60 Hz according to EPACT,


see Pages 4/72 to 4/77.

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4/68

Siemens D 81.1 2007

3)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 50 Hz

J
kgm

Measuring surface
sound pressure
level at 50 Hz
LpfA
dB(A)

0.086
0.15
0.18
0.27
0.47
0.83
1
1.4
1.6
2.1
2.5

67
71
71
71
71
73
73
76
76
76
76

80
84
84
84
84
86
86
89
89
89
89

0.12
0.14
0.23
0.4
0.49
0.86
1.4
1.7
2.3
2.9
3.5
4.2

60
60
62
60
60
65
67
67
68
68
68
68

73
73
75
73
73
78
80
80
82
82
82
82

LWA
dB(A)

2-pole, 3000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LG6 183-2AA
1LG6 206-2AA
1LG6 207-2AA
1LG6 223-2AA
1LG6 253-2AA
1LG6 280-2AB
1LG6 283-2AB
1LG6 310-2AB
1LG6 313-2AB
1LG6 316-2AB
1LG6 317-2AB

2.5
2.4
2.5
2.5
2.4
2.5
2.6
2.4
2.6
2.5
2.5

7.2
7
7.2
7.3
6.8
7
7.6
6.9
7.1
7.1
6.9

3.4
3.3
3.3
3.2
3
3
3.1
2.8
2.9
2.9
2.8

16
16
16
16
16
13
13
13
13
13
13

4-pole, 1500 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LG6 183-4AA
1LG6 186-4AA
1LG6 207-4AA
1LG6 220-4AA
1LG6 223-4AA
1LG6 253-4AA
1LG6 280-4AA
1LG6 283-4AA
1LG6 310-4AA
1LG6 313-4AA
1LG6 316-4AA
1LG6 317-4AA

2.5
2.5
2.6
2.7
2.8
2.6
2.5
2.7
2.7
2.7
3
3.2

6.4
6.7
6.7
6.8
6.9
7.5
6.8
7.5
7.1
7.3
7.4
7.6

3
3.1
3.3
3
3
3
2.9
3.1
2.9
2.9
3
3

16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

1LG6 18 . - . . .
1LG6 20 . - . . .
1LG6 22 . - . . .
1LG6 25 . - . . .
1LG6 28 . - . . .
1LG6 310 - . . .
1LG6 313 - . . .
1LG6 316 - . . .
1LG6 317 - . . .

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5 1) 3) IM V1 with IM B35
IM V3 4)
IM V6 1) 2)
protective
cover 1) 3) 5)
0
1
4
6

Standard version
Without additional charge

6)

7)

With standard flange With special


flange
IM B14, IM B34
IM B14,
1)
IM V19
IM V19 1)
2

With additional charge


Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S
to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5,
whereby one can be relocated in accordance with IM V1 or IM V3. It is
important to note that stress must not be applied perpendicular to the ring
plane.

4)

2)

If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are
fixed to the wall, it is recommended that the motor feet are supported.

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

7)

2-pole motors in 60 Hz version available on request.

Siemens D 81.1 2007

4/69

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Rated output
at
50 Hz

Frame
size

Operating values at rated output


Rated
Rated
Efficiency
speed
torque
at 50 Hz
at 50 Hz
at 50 Hz
4/4-load

Prated
kW

FS

nrated
rpm

Trated
Nm

Efficiency
at 50 Hz
3/4-load

rated

rated

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3 type
of construction
approx.
m
kg

29.5
36
42
56 1)
69
81
99
138
160 1)
196
235
280 2)

1LG6 186-6AA
1LG6 206-6AA
1LG6 207-6AA
1LG6 223-6AA
1LG6 253-6AA
1LG6 280-6AA
1LG6 283-6AA
1LG6 310-6AA
1LG6 313-6AA
1LG6 316-6AA
1LG6 317-6AA
1LG6 318-6AA

175
210
240
325
405
520
570
760
935
1010
1180
1245

23.5
30.5
36
43
57
71
86
102
138
164
200
240

1LG6 186-8AB
1LG6 207-8AB
1LG6 220-8AB
1LG6 223-8AB
1LG6 253-8AB
1LG6 280-8AB
1LG6 283-8AB
1LG6 310-8AB
1LG6 313-8AB
1LG6 316-8AB
1LG6 317-8AB
1LG6 318-8AB

165
235
295
335
435
510
560
750
840
1005
1100
1270

Power fac- Rated


tor at 50 Hz current
4/4-load
at 400 V,
50 Hz
cos rated Irated
A

6-pole, 1000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency

15
18.5
22
30
37
45
55
75
90
110
132
160

180 L
200 L
200 L
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L

975
978
978
980
985
988
988
990
990
990
990
990

147
181
215
292
359
435
532
723
868
1061
1273
1543

90.9
91.2
91.9
93.2
93.7
94.4
94.6
95
95.3
95.6
95.8
95.8

91.7
91.8
92.5
93.7
94.1
94.6
94.8
95
95.4
95.7
95.8
95.9

0.81
0.81
0.82
0.83
0.83
0.85
0.85
0.83
0.85
0.85
0.85
0.86

8-pole, 750 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
11
15
18.5
22
30
37
45
55
75
90
110
132

180 L
200 L
225 S
225 M
250 M
280 S
280 M
315 S
315 M
315 L
315 L
315 L

725
725
730
730
735
738
738
740
740
740
740
740

145
198
242
288
390
479
582
710
968
1161
1420
1704

88.7
89.3
91.1
91.6
92.8
93.1
93.7
94.3
94.5
94.7
94.8
94.9

89.6
89.8
91.8
92.1
93.3
93.3
94
94.4
94.7
95.1
95.1
95.2

0.76
0.8
0.81
0.81
0.82
0.81
0.81
0.82
0.83
0.84
0.84
0.84

Special versions according to ATEX


Motor type

Frame
size
180
200
225
250
280
315

1LG6

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 3)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

With additional charge

The motors can also be used for 60 Hz according to EPACT,


see Pages 4/72 to 4/77.

1)

For connection to 230 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

2)

For connection to 400 V, parallel feeders are necessary (see the Introduction section, Connection, circuit and connection boxes).

4/70

Siemens D 81.1 2007

3)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 50 Hz

J
kgm

Measuring
surface sound
pressure level
at 50 Hz
LpfA
dB(A)

0.2
0.29
0.36
0.63
0.93
1.4
1.6
2.5
3.2
4
4.7
5.4

56
59
59
59
59
58
58
61
61
61
61
64

69
72
72
72
72
71
71
74
74
74
74
77

0.21
0.37
0.55
0.66
1.1
1.4
1.6
2.5
3.1
3.9
4.5
5.3

62
62
54
58
57
58
58
64
58
64
64
64

75
75
67
71
70
71
71
77
72
77
77
77

LWA
dB(A)

6-pole, 1000 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LG6 186-6AA
1LG6 206-6AA
1LG6 207-6AA
1LG6 223-6AA
1LG6 253-6AA
1LG6 280-6AA
1LG6 283-6AA
1LG6 310-6AA
1LG6 313-6AA
1LG6 316-6AA
1LG6 317-6AA
1LG6 318-6AA

2.4
2.4
2.4
2.8
2.9
3
3.3
2.8
2.7
2.9
3.1
3.2

5.5
5.6
5.6
6.5
6.8
6.8
7.3
7.3
7.3
7.4
7.8
7.8

2.5
2.4
2.4
2.9
2.5
2.7
2.9
3
2.9
2.9
3.1
3.1

16
16
16
16
16
16
16
16
16
16
16
16

8-pole, 750 rpm at 50 Hz, temperature class 155 (F), IP55 degree of protection,
High Efficiency
1LG6 186-8AB
1LG6 207-8AB
1LG6 220-8AB
1LG6 223-8AB
1LG6 253-8AB
1LG6 280-8AB
1LG6 283-8AB
1LG6 310-8AB
1LG6 313-8AB
1LG6 316-8AB
1LG6 317-8AB
1LG6 318-8AB

1.7
2.3
2.3
2.4
2.5
2.3
2.6
2.5
2.5
2.4
2.4
2.5

4.6
5.3
5.6
5.8
6
5.7
6.1
6.3
6.7
6.3
6.4
6.7

2.2
2.6
2.6
2.8
2.8
2.3
2.5
2.9
2.9
2.8
2.6
2.9

13
13
13
13
13
13
13
13
13
13
13
13

Order No. supplements


Motor type

1LG6 18 . - . . .
1LG6 20 . - . . .
1LG6 22 . - . . .
1LG6 25 . - . . .
1LG6 28 . - . . .
1LG6 310 - . . .
1LG6 313 - . . .
1LG6 316 - . . .
1LG6 317 - . . .
1LG6 318 - . . .

Penultimate position: Voltage code


50 Hz
230 V/400 VY 400 V/690 VY 500 VY

500 V

Final position: Type of construction code


Without
With flange
flange
IM B3/6/7/8, IM B5 1) 3) IM V1 with IM B35
IM V6 1) 2)
protective
IM V3 4)
cover 1) 3) 5)
0
1
4
6

Standard version
Without additional charge

6)

With standard flange With special


flange
IM B14, IM B34
IM B14,
1)
IM V19
IM V19 1)
2

With additional charge


Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S to
315 L) are supplied with two screw-in eyebolts in accordance with IM B5,
whereby one can be relocated in accordance with IM V1 or IM V3. It is important to note that stress must not be applied perpendicular to the ring plane.

4)

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6 are
fixed to the wall, it is recommended that the motor feet are supported.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

2)

Siemens D 81.1 2007

4/71

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power
factor
at 60 Hz
4/4-load

Rated
current
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LG6 183-2AA
1LG6 206-2AA
1LG6 207-2AA
1LG6 223-2AA
1LG6 228-2AA
1LG6 253-2AA
1LG6 258-2AA
1LG6 280-2AB
1LG6 283-2AB
1LG6 288-2AA
1LG6 310-2AB
1LG6 313-2AB
1LG6 316-2AB
1LG6 317-2AB
1LG6 318-2AA

180
225
255
330
390
420
470
530
615
660
790
915
1055
1245
1330

2-pole, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

30
40
50
60
75
75
100
100
125
150
150
175
200
250
300

180 M
200 L
200 L
225 M
225 M
250 M
250 M
280 S
280 M
280 M
315 S
315 M
315 L
315 L
315 L

3560
3565
3565
3570
3570
3578
3580
3580
3580
3580
3585
3586
3588
3588
3591

60
80
100
120
150
149
199
199
249
299
298
348
397
496
595

Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No

93
91.7
92.4
93.6
94.5
93.6
94.1
95
95
95
94.5
95
95.4
95.4
95.4

0.88
0.88
0.89
0.89
0.9
0.89
0.89
0.89
0.9
0.9
0.91
0.91
0.91
0.93
0.92

34
46
57
67
83
84
112
110
136
164
164
190
215
265
320

1)

1)

1)

1)

Special versions according to ATEX


Motor type

Frame size
180
200
225
250
280
315

1LG6

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/68 to 4/71.

1)

Only 60 Hz data according to EPACT on the rating plate.

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/72

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 60 Hz

J
kgm

Measuring
surface sound
pressure level
at 60 Hz
LpfA
dB(A)

0.086
0.15
0.18
0.27
0.32
0.47
0.57
0.83
1
1.16
1.4
1.6
2.1
2.5
2.74

72
75
75
74
74
75
79
77
77
77
81
81
81
81
83

85
88
88
87
87
88
92
90
90
90
94
94
94
94
96

LWA
dB(A)

2-pole, 3600 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT
1LG6 183-2AA
1LG6 206-2AA
1LG6 207-2AA
1LG6 223-2AA
1LG6 228-2AA
1LG6 253-2AA
1LG6 258-2AA
1LG6 280-2AB
1LG6 283-2AB
1LG6 288-2AA
1LG6 310-2AB
1LG6 313-2AB
1LG6 316-2AB
1LG6 317-2AB
1LG6 318-2AA

2.7
2.7
2.8
2.8
3.3
2.7
2.8
2.8
2.9
3.1
2.6
3
3
3.2
4.1

7.9
7.8
7.8
8.3
8.7
7.5
8.4
7.9
8.3
8.5
7.5
8.3
8.4
8.6
10

3.7
3.7
3.7
3.6
3.7
3.2
3.5
3.4
3.4
3.6
3.1
3.3
3.5
3.4
3.9

16
16
16
16
16
16
16
13
13
16
13
13
13
13
16

Order No. supplements


Motor type

1LG6 18 . - . . .
1LG6 20 . - . . .
1LG6 22 . - . . .
1LG6 25 . - . . .
1LG6 28 . - . . .
1LG6 310 - . . .
1LG6 313 - . . .
1LG6 316 - . . .
1LG6 317 - . . .
1LG6 318 - . . .

Penultimate position:
Voltage code
60 Hz
460 VY
460 V
(see Introduction
for outputs at 60 Hz)
1
6

Final position: Type of construction code


Without flange With flange
IM B3/6/7/8,
IM B5, IM V3 IM V1 with
1) 3) 4)
IM V6 1) 2)
protective
cover 1) 3) 5)
0

6)

IM B35

With standard flange


IM B14,
IM B34
IM V19 1)

With special flange


IM B14, IM V19 1)

7)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S
to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5,
whereby one can be relocated in accordance with IM V1 or IM V3. It is
important to note that stress must not be applied perpendicular to the ring
plane.

4)

2)

If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

7)

2-pole motors in 60 Hz version available on request.

Siemens D 81.1 2007

4/73

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power
factor
at 60 Hz
4/4-load

Rated
current
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LG6 183-4AA
1LG6 186-4AA
1LG6 207-4AA
1LG6 220-4AA
1LG6 223-4AA
1LG6 228-4AA
1LG6 253-4AA
1LG6 258-4AA
1LG6 280-4AA
1LG6 283-4AA
1LG6 288-4AA
1LG6 310-4AA
1LG6 313-4AA
1LG6 316-4AA
1LG6 317-4AA
1LG6 318-4AA

155
180
225
290
330
355
460
495
575
675
710
810
965
1105
1305
1345

4-pole, 1800 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

25
30
40
50
60
75
75
100
100
125
150
150
175
200
250
300

180 M
180 L
200 L
225 S
225 M
225 M
250 M
250 M
280 S
280 M
280 M
315 S
315 M
315 L
315 L
315 L

1775
1775
1775
1785
1785
1785
1790
1788
1788
1790
1788
1791
1791
1792
1792
1792

100
120
160
199
239
299
298
398
398
497
598
596
696
795
994
1193

Yes
Yes
Yes
No
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No

92.4
92.4
93
93.6
94.1
94.1
94.5
94.5
94.5
95
95
95
95.4
95.4
95.8
95.8

0.82
0.83
0.84
0.84
0.85
0.85
0.86
0.86
0.86
0.86
0.86
0.87
0.87
0.87
0.87
0.87

31
36.5
48
60
70
88
86
116
114
144
172
170
198
225
280
335

1)

1)

1)

1)

Special versions according to ATEX


Motor type

Frame size
180
200
225
250
280
315

1LG6

Zone 2
Mains-fed
operation
Order code
M72

VIK (includes Zone 2) 2)


Converter-fed Mains-fed
Converter-fed
operation (FC) operation
operation (FC)
Order code
Order code
On request
M73
K30

With additional charge

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/68 to 4/71.

1)

Only 60 Hz data according to EPACT on the rating plate.

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/74

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Rated output Frame
at 60 Hz
size

Operating values at rated output


Rated speed Rated torque EPACT with
at 60 Hz
at 60 Hz
CC No. CC
032A

Prated
HP

nrated
rpm

FS

Trated
Nm

Nominal
efficiency
at 60 Hz

Power
factor
at 60 Hz
4/4-load

Rated
current
at 460 V,
60 Hz

rated

cos rated

Irated
A

Order No.
Price
For order No. supplements for voltage, type
of construction and
explosion protection
zones according to
ATEX, see tables below

Weight
IM B3
type of
construction
approx.
m
kg

1LG6 186-6AA
1LG6 206-6AA
1LG6 207-6AA
1LG6 223-6AA
1LG6 228-6AA
1LG6 253-6AA
1LG6 258-6AA
1LG6 280-6AA
1LG6 283-6AA
1LG6 288-6AA
1LG6 310-6AA
1LG6 313-6AA
1LG6 316-6AA
1LG6 317-6AA
1LG6 318-6AA

175
210
240
325
355
405
435
520
570
615
760
935
1010
1180
1245

6-pole, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT

20
25
30
40
50
50
60
60
75
100
100
125
150
175
200

180 L
200 L
200 L
225 M
225 M
250 M
250 M
280 S
280 M
280 M
315 S
315 M
315 L
315 L
315 L

1178
1180
1180
1184
1184
1186
1186
1190
1190
1190
1191
1191
1192
1192
1192

121
151
181
241
301
300
361
359
449
599
598
747
896
1046
1195

Yes
Yes
Yes
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes

91
91.7
91.7
93
93
93
93.6
94.1
94.5
94.5
94.5
94.5
95
95
95.4

0.8
0.79
0.8
0.82
0.83
0.82
0.82
0.83
0.83
0.84
0.82
0.84
0.84
0.84
0.84

25.5
32.5
38.5
49
61
61
73
72
89
118
120
148
176
205
235

1)

1)

1)

Special versions according to ATEX


Motor type

Frame size
180
200
225
250
280
315

1LG6

Zone 2
Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73

VIK (includes Zone 2) 2)


Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

With additional charge

The motors can also be used for 50 Hz High Efficiency,


see Pages 4/68 to 4/71.

1)

Only 60 Hz data according to EPACT on the rating plate.

2)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/76

Siemens D 81.1 2007

Zone 21
Mains-fed
operation
Order code
M34

Converter-fed
operation (FC)
Order code
M38

Zone 22
Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2, 21, 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LG6

Selection and ordering data (continued)


Order No.

Locked-rotor
Locked-rotor
Breakdown
torque
current
torque
with direct starting as multiple of rated
torque
current
torque

Torque class

TLR/Trated

CL

ILR/Irated

TB/Trated

Moment of inertia Noise at rated output


Sound pressure
level at 60 Hz

J
kgm

Measuring
surface sound
pressure level
at 60 Hz
LpfA
dB(A)

0.2
0.29
0.36
0.63
0.76
0.93
1.07
1.4
1.6
1.94
2.5
3.2
4
4.7
5.4

57
65
65
62
61
63
65
62
62
64
66
66
66
66
69

70
78
78
75
74
76
79
75
75
78
79
79
79
79
82

LWA
dB(A)

6-pole, 1200 rpm at 60 Hz, temperature class 155 (F), IP55 degree of protection,
for implementation in the North American market according to EPACT
1LG6 186-6AA
1LG6 206-6AA
1LG6 207-6AA
1LG6 223-6AA
1LG6 228-6AA
1LG6 253-6AA
1LG6 258-6AA
1LG6 280-6AA
1LG6 283-6AA
1LG6 288-6AA
1LG6 310-6AA
1LG6 313-6AA
1LG6 316-6AA
1LG6 317-6AA
1LG6 318-6AA

2.9
2.9
2.9
3.4
3.2
3.4
3.4
3.6
3.9
4
3.3
3
3.3
3.6
4

6.5
6.5
6.4
7.2
7.6
7.4
7.4
7.7
8.3
8.4
8.4
7.9
8.5
8.9
9.4

3
2.7
2.7
3.4
3.4
2.9
2.9
3.1
3.3
3.3
3.4
3.1
3.3
3.6
4

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

Order No. supplements


Motor type

1LG6 18 . - . . .
1LG6 20 . - . . .
1LG6 22 . - . . .
1LG6 25 . - . . .
1LG6 28 . - . . .
1LG6 310 - . . .
1LG6 313 - . . .
1LG6 316 - . . .
1LG6 317 - . . .
1LG6 318 - . . .

Penultimate position:
Voltage code
60 Hz
460 VY
460 V
(see Introduction
for outputs at 60 Hz)
1
6

Final position: Type of construction code


Without flange With flange
IM B3/6/7/8,
IM B5, IM V3 IM V1 with
1) 3) 4)
IM V6 1) 2)
protective
cover 1) 3) 5)
0

6)

IM B35

With standard flange


IM B14,
IM B34
IM V19 1)

With special flange


IM B14, IM V19 1)

Standard version
Without additional charge
With additional charge
Not possible

Order other voltages with voltage code 9 in the penultimate position and the corresponding order code (see Special versions
in the Selection and ordering data under Voltages).

Order other types of construction with type of construction code


9 in the final position and the corresponding order code (see
Special versions in the Selection and ordering data under
Types of construction).

1)

The following applies for explosion-proof motors: In the case of the types
of construction with shaft extension down, the version with protective
cover is required. For types of construction with shaft extension pointing
upwards, a suitable cover must be implemented to prevent small parts
from falling into the fan cover (see the standard IEC/EN 60079-0). The
cover must not block the cooling air-flow.

3)

1LG6 220-... to 1LG6 318-... motors (motor series 1LG6 frame sizes 225 S
to 315 L) are supplied with two screw-in eyebolts in accordance with IM B5,
whereby one can be relocated in accordance with IM V1 or IM V3. It is
important to note that stress must not be applied perpendicular to the ring
plane.

4)

2)

If motors 1LG6 183-... to 1LG6 318-... (motor series 1LG6 frame sizes
180 M to 315 L) in types of construction with feet IM B6, IM B7 or IM V6
are fixed to the wall, it is recommended that the motor feet are supported.

Type of construction IM V3 is only possible using type of construction code


9 and order code M1G.

5)

The Second shaft extension option, order code K16 is not possible.

6)

Type of construction IM V6 is only possible using type of construction code


9 and order code M1E.

Siemens D 81.1 2007

4/77

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Self-ventilated, in Zones 2 and 22 with type of prot. "n" or
prot. against dust explosions - Cast-iron series 1LA8

Selection and ordering data


The data for series 1LA8 with type of protection n or protection
against dust explosions can be found in the selection and ordering data in the Non-standard motors of frame size 315 and
above section of the catalog. The technical specifications are
identical to the specifications of the non-explosion-proof ver-

sions. They are ordered using additional order options (special


versions). These special versions for voltages, construction
types or options are listed in Section 3 of the catalog.

Special versions according to ATEX


Motor type

1LA8

Zone 2

Frame
size
315
355
400
450

Mains-fed
operation
Order code
M72

Converter-fed
operation (FC)
Order code
M73
O. R.
O. R.
O. R.
O. R.

VIK 1)
(includes Zone 2, utilization F
according to B)
Mains-fed
Converter-fed
operation
operation (FC)
Order code
On request
K30

O. R.

O. R.

Zone 21

Mains-fed
operation
Order code
M34

Zone 22

Converter-fed
operation (FC)
Order code
M38

Mains-fed
operation
Order code
M35

Converter-fed
operation (FC)
Order code
M39

O. R. Possible on request

With additional charge

Not possible

Forced-air cooled, in Zones 2 and 22 with type of prot. n


or prot. against dust explosions - Cast-iron series 1PQ8

Selection and ordering data


The data for series 1PQ8 with type of protection n or protection
against dust explosions can be found in the selection and ordering data in the Non-standard motors of frame size 315 and
above section of the catalog. The technical specifications are
identical to the specifications of the non-explosion-proof ver-

1)

If the marking Ex nA II is required in addition to VIK on the rating plate, this


must be ordered using order code C27. The VIK version is not possible in
combination with Zone 21 and 22.

4/78

Siemens D 81.1 2007

sions. They are ordered using additional order options (special


versions). These special versions for voltages, construction
types or options are listed in Section 3 of the catalog. Motor series 1PQ8 for converter-fed operation in Zone 2 available on request.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Overview
Overall dimensions

AD

G_D081_XX_00033

AB

Frame
size
56 M

63 M

71 M

80 M

90 S/
90 L

100 L

112 M

132 S/
132 M

Type

Number Dimensions
of poles L
AD
1LA7
169
101
1LA9 050
169
101
1LA9 053
195
101
1LA7
202.5 101
1LA9 063
202.5 101
1LA9 061
228.5 101
1MA7
202.5 135
1LA7
240
111
1LA9
240
111
1MA7
240
145
1MJ6
299
201
1LA7
273.5 120
1LA9 080
273.5 120
1LA9 083
308.5 120
1MA7
273.5 154
1MA7 083-6.
308.5 154
1MJ6
336
209
1LA7
331
128
1LA9
331
128
1LA9 096-6K.
376
128
1LA9 096-2..
358
128
1LA9 096-4..
358
128
1MA7
331
162
1MJ6
383
218
1LA6
372
164
1LA7
372
135
1LA9
407
135
1LA9 107-4KA.
442
135
1MA6
372
164
1MA7
372
135
1MJ6
426
223
1LA6
393
178
1LA7
393
148
1LA9
431
148
1MA6
393
178
1MA7
393
148
1MJ6
428
238
1LA6
453
194
1LA7
452.5 167
1LA9
452.5 167
1LA9 131
490.5 167
1LA9 133
4
490.5 167
1LA9 134
490.5 167
1MA6
453
194
1MA7
452.5 167
1MA7 133-4
490
167
1MJ6
515
258

H
56
56
56
63
63
63
63
71
71
71
71
80
80
80
80
80
80
90
90
90
90
90
90
90
100
100
100
100
100
100
100
112
112
112
112
112
112
132
132
132
132
132
132
132
132
132
132

AB
110
110
110
120
120
120
120
132
132
132
140
150
150
150
150
150
160
165
165
165
165
165
165
168
196
196
196
196
196
196
196
226
226
226
226
226
226
256
256
256
256
256
256
256
256
256
256

O
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
1 x M25 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5
2 x M32 x 1.5

Frame Type
size
160 M/ 1LA6
160 L
1LA7
1LA9
1LA9 166
1MA6
1MA7
1MA7 166-4
1MA7 166-6
1MJ6
180 M/ 1LA5
180 L
1LA9
1LG4
1LG4 188
1LG6 183
1LG6 183
1LG6 186
1MJ6
200 L
1LA5
1LA9
1LG4
1LG4 208
1LG6 206
1LG6 207
1LG6 207
1MJ6
225 S/ 1LA5
225 M 1LA5
1LG4
1LG4 223
1LG4 228
1LG4 228
1LG6 220
1LG6 223
1LG6 223
1LG6 228
1LG6 228
1MJ7
1MJ7 223

4
Number Dimensions
of poles L
AD
588
226
588
197
588
197
628
197
588
226
588
197
628
197
628
197
641
280
712
258
712
258
669
262
720
262
2
720
262
4
669
262
4, 6, 8
720
262
715
306
769.5 305
768.5 305
720
300
2, 6
777
300
720
300
2, 6
777
300
4, 8
720
300
771.5 349
806
305
2
776
305
789
325
2
759
325
2
819
325
4, 6, 8
849
325
4, 8
789
325
2
819
325
4, 6, 8
849
325
2
869
325
4, 6
899
325
839
377
2
809
377

H
160
160
160
160
160
160
160
160
160
180
180
180
180
180
180
180
180
200
200
200
200
200
200
200
200
225
225
225
225
225
225
225
225
225
225
225
225
225

AB
300
300
300
300
300
300
300
300
300
339
339
339
339
339
339
339
339
388
388
378
378
378
378
378
398
426
426
436
436
436
436
436
436
436
436
436
436
436

Siemens D 81.1 2007

O
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M40 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5
2 x M50 x 1.5

4/121

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Overview (continued)
Overall dimensions

AD

G_D081_XX_00033

AB

Frame Type
size
250 M 1LG4
1LG4 258
1LG6 253
1LG6 253
1LG6 258
1MJ7
280 S/ 1LG4
280 M 1LG4 288
1LG6 280
1LG6 283
1LG6 283
1LG6 288
1MJ7
315 S/ 1LG4
315 M/ 1LG4 310
315 L 1LG4 313
1LG4 316
1LG4 316
1LG4 317
1LG4 317
1LG4 318
1LG4 318
1LG6 310
1LG6 310
1LG6 313
1LG6 313
1LG6 313
1LG6 316
1LG6 316
1LG6 317
1LG6 317
1LG6 317
1LG6 318
1LG6 318
1LG6 318
1MJ1 313
1MJ1 313
1MJ1 314
1MJ1 316
1MJ1 316
1MJ1 318
1MJ1 318
1MJ7
1MJ7

Number Dimensions
of poles L
AD
887
392
4
957
392
2, 6, 8
887
392
4
957
392
2, 4, 6
957
392
930
466
960
432
2, 4
1070
432
2, 4, 6, 8 960
432
2, 4
1070
432
6, 8
960
432
2, 4, 6
1070
432
1010
491
1072
500
4, 6, 8
1102
500
4, 6, 8
1102
500
2
1232
500
4, 6, 8
1262
500
2
1232
500
4, 6, 8
1262
500
8
1262
500
6
1402
500
2
1072
500
4, 6, 8
1102
500
2
1232
500
4, 6
1262
500
8
1102
500
2
1232
500
4, 6, 8
1262
500
2
1372
500
4, 6
1402
500
8
1262
500
2
1372
651
4
1402
651
6, 8
1402
500
2
1304
587
4, 6, 8
1334
587
6, 8
1334
587
2
1491
676
4, 6, 8
1521
676
2
1491
676
4, 6, 8
1521
676
2
1114
558
4, 6, 8
1140
558

H
250
250
250
250
250
250
280
280
280
280
280
280
280
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
315
316
315
315
315

AB
490
490
490
490
490
506
540
540
540
540
540
540
557
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
610
630
630
630
630
630
630
630
628
628

O1)
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5
2 x M63 x 1.5

Frame Type
size
355
1MJ1 357
1MJ1 358
1MJ1 358

400

1MJ8 350
1MJ8 356
1MJ8 356
1MJ8 357
1MJ8 357
1MJ8 357
1MJ8 358
1MJ8 358
1LA8
1PQ8
1PQ8
1LL8
1LL8
1MJ1 404
1MJ1 405
1MJ1 405
1MJ1 407
1MJ1 407
1MJ1 408
1MJ1 408

450

1MJ1 450
1MJ1 453
1MJ1 455
1MJ1 455
1MJ1 457
1MJ1 457
1MJ1 458
1MJ1 458
1MJ1 458
1MJ1 458

1)

For 1MJ8 frame size 355 in type of construction IM B3, cable entry
from drive-end DE, in types of construction IM B35, IM B5 and IM V1
cable entry from right side.

2)

Dimensions for standard connection boxes. Dimensions for explosionproof connection boxes type of protection Ex d IIC order code K53 are
available on request.

3)

The connection box is on the side. The value without brackets is the
dimension upwards. The value in brackets () is the sideways dimension (top of connection box).

4/122

Siemens D 81.1 2007

Number Dimensions
of poles L
AD
4, 6, 8
1900
675
(930)2)3)
2
2016
675
(930)2)3)
4, 6, 8
1900
675
(930)2)3)
4
1855
707
2
1870
707
4, 6, 8
1755
707
2
1950
707
4
1855
707
6
1855
707
2
1950
707
4, 6, 8
1855
707
4, 6, 8
1825
865
2
2150
865
4, 6, 8
2190
865
2
1793
865
4, 6, 8
1833
865
8
2025
645
(980)2)3)
645
2
2131
(980)2)3)
645
4, 6
2025
(980)2)3)
645
2
2131
(980)2)3)
645
4, 6, 8
2025
(980)2)3)
645
2
2131
(980)2)3)
645
4, 8
2025
(980)2)3)
8
2180
745
(1010)2)3)
6
2180
745
(1010)2)3)
2
2251
745
(1010)2)3)
4, 6, 8
2180
745
(1010)2)3)
2
2251
745
(1010)2)3)
4, 6, 8
2180
745
(1010)2)3)
2
2251
745
(1010)2)3)
4
2180
745
(1010)2)3)
6
2180
745
(1010)2)3)
8
2180
745
(1010)2)3)

H
355

AB
780

O1)
35 75

355

780

35 75

355

780

35 75

355
355
355
355
355
355
355
355
400
400
400
400
400
400

700
700
700
700
700
700
700
700
860
860
860
860
860
860

35 75
35 75
35 75
35 75
35 75
35 75
35 75
35 75
80
80
80
80
80
35 75

400

860

35 75

400

860

35 75

400

860

35 75

400

860

35 75

400

860

35 75

400

860

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

450

900

35 75

Only overall dimensions are specified for 1MJ1 and 1MJ8


motors, complete dimension drawings are not provided in
this catalog. The relevant dimension drawings can be
ordered separately.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Overview (continued)
Notes on the dimensions
7 Dimension designations according to DIN EN 50347 and
IEC 60072.
7 Fits
The shaft extensions specified in the dimension tables (DIN 748)
and centering spigot diameters (DIN EN 50347) are machined
with the following fits:
Dimension designation
ISO fit DIN ISO 286-2
D, DA
up to 30
j6
over 30 to 50
k6
over 50
m6
N
up to 250
j6
over 250
h6
F, FA
h9
K
H17
S
flange (FF)
H17
The drilled holes of couplings and belt pulleys should have an
ISO fit of at least H7.

Dimension tolerances
For the following dimensions, the admissible deviations are
given below:
Dimension designation
Dimension
Admissible
deviation
H
up to 250
0.5
over 250
1.0
E, EA
0.5
Keyways and feather keyways (dimensions GA, GC, F and FA)
are made in compliance with DIN 6885 Part 1.
7 All dimensions are specified in mm.
7

More information
Dimension sheet generator
(part of the SD configurator)
A dimension drawing can be created in the SD configurator
for every configurable motor. A dimension drawing can be
requested for every other motor.

When a complete Order No. is entered with or without order


codes, a dimension drawing can be called up under the Documentation tab.
These dimension drawings can be presented in different views
and sections and printed.
The corresponding dimension sheets can be exported, saved
and processed further in DXF format (interchange/import format
for CAD systems) or as bitmap graphics.
The SD configurator has been integrated into the electronic
catalog CA 01 as a selection aid (for more information, see
Technical information, Project planning aids).
The interactive catalog CA 01 can be ordered from your local Siemens sales representative or on the Internet at
http://www.siemens.com/automation/CA01
At this address, you will also find links to Tips & Tricks and to
downloads for function or content updates.
Order number for CA 01 10/2007, English International:
CD-ROM: E86060-D4001-A110-C6-7600
DVD:
E86060-D4001-A510-C6-7600

Siemens D 81.1 2007

4/123

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1MA7, frame sizes 63 M to 160 L
Type of construction IM B3
G_D081_EN_00001

ED

AG
AS

BC

GC

EC

EB
DB

Frame size 90 S/L has


frame feet each with
2 drilled holes at NDE.

AQ

BE

GA

FA

AC

BE'

Eyebolts frame size


100 L and above

LM

DA

EE

AF
AD

LC
L
LL

DC

CA

K'

HA

K
E

EA

BA

AF'
BA

BB

AD'

AA

CA
BA'

AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00002

HH
LL

GA

DB

FA

EC

GC

DC

EE
ED

For motor
Frame Type
size
63 M 1MA7 060
1MA7 063
71 M 1MA7 070
1MA7 073
80 M 1MA7 080
1MA7 083
90 S 1MA7 090
90 L 1MA7 096
100 L 1MA7 106
1MA7 107
112 M 1MA7 113
132 S 1MA7 130
1MA7 131
132 M 1MA7 133
1MA7 134
160 M 1MA7 163
1MA7 164
160 L 1MA7 166

AQ

AC

BE

EA

Dimension designation acc. to IEC


A
AA
AB AC1) AD AD' AF

Number
of poles
2, 4, 6

100

27

120 124 135 101

95

78

120 124 60

80

28

96 52.5 32

16

40

66

63

2, 4, 6, 8

112

27

132 145 145 111 105

88

120 124 60

90

27

106 41.5 32

16

45

83

71

2, 4, 6, 8

125

30.5 150 163 154 154 114 114 120 124 60

100 32

118 36

32

16

50

80

2, 4, 6, 8

140

30.5 165 180 162 162 122 122 120 170 60

54

143 46

32

16

90

10

2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

160

42

196 203 135 163

123 120 170 60

100 33
125
140 47

176 39

42

190
216

46
53

226 227 148 176 91 136 120 170 60


256 267 167 194 107 154 140 250 70

140 47
140 49

176 32
180 39

216

53

256 267 167 194 107 154 140 250 70

178 49

218 39

78

AF'

AG

AQ

AS

B*

BA BA' BB

BC

BE BE' C

42
42

21
21

70 141
89 162.5

112 12
132 15

42

21

60

300 320 197 226 127 183 165 250 82.5 210 57

256 52.5 54

27

300 320 197 226 127 183 165 250 82.5 254 57

300 52.5 54

27

2)

For 1MA7 083-6.

Siemens D 81.1 2007

For 1MA7 133-4.

4)

For 1MA7 166-4 and 1MA7 166-6.

HA

100 12

60

3)

21

254

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

CA*

94
1342)
56 143
118
63 125

254

1)

4/124

Eyebolts frame size


100 L and above

LM

DA

BE'
EB

AG
AS

AF
AD

LC
L

89 124.5 132 15
162.53)
108 183
160 18
108 139
1794)

160 18

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1MA7, frame sizes 63 M to 160 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00003

BC

EC

DB

GC

DC

K
ED

EE

CA

BA

A
AA

BA

CA

AF'

K'

HA

GA

AC

BE

Frame size 90 S/L has


frame feet each with
2 drilled holes at NDE.

AQ

EA

FA

BE'

Eyebolts frame size


100 L and above

LM

DA

EB

AG
AS

AF
AD

LC
L
LL

BA'
BB

AD'
AB

BB

Type of construction IM B14


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)

AC

AQ

EA

GA

Eyebolts frame size


100 L and above

LM

DA

BE'
BE

EB

AG
AS

AF
AD

LL

FA

HH

G_D081_EN_00004

LC
L

EC

GC
DC

DB

For motor
Frame Type
size
63 M 1MA7 060
1MA7 063
71 M 1MA7 070
1MA7 073
80 M 1MA7 080
1MA7 083
90 S 1MA7 090
90 L 1MA7 096
100 L 1MA7 106
1MA7 107
112 M 1MA7 113
132 S 1MA7 130
1MA7 131
132 M 1MA7 133
1MA7 134
160 M 1MA7 163
1MA7 164
160 L 1MA7 166

1)

ED

Number
of poles
2, 4, 6
2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

EE

Dimension designation acc. to IEC


HH
K
K'
L
LC
92.5

10

202.5

86.5

10

240

1)

232

1)

LL

DE shaft extension
D DB E
EB

LM

NDE shaft extension


GA DA DC EA EC EE

FA GC

11 M4

23

16

3.5

4 12.5 11

M4

23

16

3.5

4 12.5

14 M5

30

22

5 16

14

M5

30

22

5 16

324
9.5 13.5 273.5
308.52) 364
101.5 10
14
331
389

120 299.5 19 M6
334.52)
120 382.5 24 M8

40

32

6 21.5 19

M6

40

32

6 21.5

50

40

8 27

19

M6

40

32

6 21.5

102

12

16

372

120 423.5

28 M10

60

50

8 31

24

M8

50

40

8 27

102
128

12
12

16
16

393
461
452.53) 551.5

120 444.5
140 5053)

28 M10
38 M12

60
80

50
70

5
5

8 31
10 41

24
38

M8
50
M12 80

40
70

5
5

8 27
10 41

128

12

16

38 M12

80

70

10 41

38

M12 80

70

10 41

160.5 15

19

452.53) 551.5
140 5053)
490.54) 589.54)
5434)
588
721
165 640.5

42 M16 110

90 10

12 45

42

M16 110

90 10

12 45

160.5 15

19

165 640.5 42 M16 110


680.55)

90 10

12 45

42

M16 110

90 10

12 45

278

86

588
6285)

438

721
7615)

120 231.5

1)

ED

120 268

For 1MA7 063 with type of construction code 1 (B5, IM V1 without protective cover, IM V3) the dimensions L, LC and LM are 26 mm longer.

2)

For 1MA7 083-6.

3)

In a low-noise version, the dimension L is 8 mm greater and the dimension LM is 11.5 mm greater.

4)

For 1MA7 133-4.

5)

For 1MA7 166-4 and 1MA7 166-6.

Siemens D 81.1 2007

4/125

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MA6, frame sizes 100 L to 160 L
Type of construction IM B3

AQ

AC

BC

GC

EC

EB
DB

FA

BE'

AF
AD

LM

BE

GA

EE

AG
AS

DA

ED

G_D081_XX_00007

LC
L
LL

DC

CA

K'

HA

K
E

EA

BA

AF'
A
AD'

AA
AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00008

EE

DC

AF'
AD

ED

For motor
Frame Type
size
100 L 1MA6 106
1MA6 107
112 M 1MA6 113
132 S 1MA6 130
1MA6 131
132 M 1MA6 133
1MA6 134
160 M 1MA6 163
1MA6 164
160 L 1MA6 166

Number
of poles
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AF'

AG

AQ

AS

160 40

BA

BB

BC

BE BE' C

CA

HA

164

124

124

121

170

60.5 140 46

180 42

44

22

63 125

100 12

190 42.5 226 225.5 178


216 50
256 265 194

178
194

138
154

138
154

121
141

170
250

60.5 140 46
70.5 140 47

180 34
180 42

44
44

22
22

70 141
89 162.5

112 15
132 17

216 50

256 265

194

194

154

154

141

250

70.5 178 49

218 42

44

22

89 124.5

132 17

254 60

300 320

226

226

183

183

166

250

83

210 63

256 52

54

27

108 183

160 18

254 60

300 320

226

226

183

183

166

250

83

254 63

300 52

54

27

108 139

160 18

Siemens D 81.1 2007

196 201

164

Measured across the bolt heads.

4/126

GC

EC

EA

1)

AQ

AC

BE

GA

DB

LM

DA

BE'
EB

AG
AS

FA

LL

AF
AD

LC
L
HH

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MA6, frame sizes 100 L to 160 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00009

BC

EC

DB

DC

K
ED

EE

CA

GC

AF'

K'

HA

AC

GA

AQ

EA

BE

FA

BE'

LM

DA

EB

AG
AS

AF
AD

LC
L
LL

A
AA

BA

AD'
AB

BB

Type of construction IM B14


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00010

LL

LM

AQ

AC

EA

FA

DA

BE'
BE

EB

AG
AS

AF
AD

LC
L
HH

GA

GC

EC
DC

DB

For motor
Frame Type
size
100 L 1MA6 106
1MA6 107
112 M 1MA6 113
132 S 1MA6 130
1MA6 131
132 M 1MA6 133
1MA6 134
160 M 1MA6 163
1MA6 164
160 L 1MA6 166

ED

Number
of poles
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

EE

Dimension designation acc. to IEC


HH
K
K'
L
LC
LL
438

LM

DE shaft extension
D
DB E
EB

ED

NDE shaft extension


GA DA DC EA EC EE

FA

GC

104.5 12

16

372

121 423.5

28

M10

60

50

31

24

M8

50 40

27

104.5 12
130.5 12

16
16

393
461
121 444.5
453.5 551.5 141 506

28
38

M10
M12

60
80

50
70

5
5

8
10

31
41

24
38

M8
M12

50 40
80 70

5
5

8
10

27
41

130.5 12

16

453.5 551.5 141 506

38

M12

80

70

10

41

38

M12

80 70

10

41

160

14.5 18

588

721

166 640.5

42

M16 110

90

10

12

45

42

M16 110 90

10

12

45

160

14.5 18

588

721

166 640.5

42

M16 110

90

10

12

45

42

M16 110 90

10

12

45

Siemens D 81.1 2007

4/127

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MA6, frame sizes 180 M to 315 L
Type of construction IM B3
AG
AS

GC

K
CA

DB
E

B
BA

DC
EA

BA'
BB

BC

HA

GA

AQ

AC

EC

AF
AD

LM,
LM'

FA

BE

EB

EE

DA

LL

ED

G_D081_XX_00011

LC
L, L'

Frame sizes 180 M/L, 225 S/M,


280 S/M and 315 S/M have
frame feet each with 2 drilled
holes at NDE.

K'

AF'
A

AA

AA
AD'
AB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00012

LC

LM,
LM'

GC
AH

GA

AQ

AC

EC

AG

AF
AD

BE
EB

AS

FA

EE

DA

L, L'
LL

ED

DB
HH

For motor
Frame Type
size
180 M 1MA6 183
180 L
200 L

1MA6 186
1MA6 206
1MA6 207

225 S
225 M

1MA6 220
1MA6 223

250 M

1MA6 253

280 S

1MA6 280

280 M

1MA6 283

315 S

1MA6 310

315 M

1MA6 313

315 L

1MA6 316
1MA6 317
1MA6 318

Number
of poles
2
4
4, 6, 8
2
6
2
4, 6, 8
4, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
6, 8

DC
EA
The motors are supplied with two fitted eyebolts conforming to IM B5,
whereby one can be repositioned to conform to IM V1 or IM V3. It is important
to note that stress must not be applied perpendicular to the ring plane.

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AF'

AQ

AS

B*

BA

BA'

BB

BC BE

CA* H

HA

65

344 375 274 274 227 227 220 470 340

82 241

70 108 319 35

75

121 259 180 26

279
318

65
80

344 375 274 274 227 227 220 470 340


398 402 308 308 248 248 262 530 340

82 279
99 305

70 108 319 35
85 85 355 42

75
85

121 221 180 26


133 239 200 34

318

80

398 402 308 308 248 248 262 530 340

99 305

85

355 42

85

133 239 200 34

356
356

80
80

436 442 339 339 269 269 264 580 425 100 286
436 442 339 339 269 269 264 580 425 100 311

85 110 361 25
85 110 361 25

85
85

149 269 225 34


149 244 225 34

406 100 506 505 427 427 333 333 338 645 470 120 349 100 100 409 39

95

168 283 250 42

457 100 557 555 452 452 358 358 338 700 525 120 368 100 151 471 30

95

190 317 280 42

457 100 557 555 452 452 358 358 338 700 525 120 419 100 151 471 30

95

190 366 280 42

508 120 628 620 515 515 395 395 405 805 590 134 406 125 171 527 32

90

216 358 315 52

508 120 628 620 515 515 395 395 405 805 590 134 457 125 171 527 32

90

216 307 315 52

508 120 628 620 515 515 395 395 405 805 590 134 508 120 120 578 32

90

216 396 315 52

This dimension is assigned in DIN EN 50347 to the frame size listed.

4/128

AH

279

Dimensions for 9-terminal connection box can be supplied on


request.
*

AG

Siemens D 81.1 2007

1)

85

Measured across the bolt heads.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MA6, frame sizes 180 M to 315 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)

AF
AD

AC
BC

GC

EE

DB

K
CA

HA

K'

DC

AF'
A

EA

BA'

BA

D
E
ED

GA

AQ

EC

LM

FA

BE
EB

AG
AS

DA

LL

Eyebolts from
size 100 L

G_D081_EN_00024

LC
L, L'

AD'
AA

AA

BB

AB

For motor
Frame Type
size
180 M 1MA6 183
180 L
200 L

1MA6 186
1MA6 206
1MA6 207

225 S
225 M

1MA6 220
1MA6 223

250 M

1MA6 253

280 S

1MA6 280

280 M

1MA6 283

315 S

1MA6 310

315 M

1MA6 313

315 L

1MA6 316
1MA6 317
1MA6 318

Number
of poles
2
4
4, 6, 8
2
6
2
4, 6, 8
4, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
6, 8

Dimension designation acc. to IEC


HH K K' L
L'1)
LC2) LL
156 15 20
156 15 20
175 19 25
175 19 25
174 19 25
174 19 25
207 24 30
220 24 30
220 24 30
248 28 35
248 28 35
248 28 35

715

770

715

819.5
771.5
771.5 819.5

839

809
855
839

935 1010

1010 1080

1010 1080

1114 1185
1144

1114 1185
1144

1254 1325
1284

1284

841 164
841 164
897 197
897 197
954
924
954
1050
1080
1155

200
200
234
234

1155 234
1260 266
1290
1260 266
1290
1400 266
1430
1430

1)

For version with low-noise fan.

2)

In the low-noise version, a second shaft extension is not possible.

LM

DE shaft extension
LM'1) D DB
E
EB ED F

796.5 855

796.5
853
901

853
901

935

909
955
935

1035 1110

1120 1230

1120 1230

1224 1295
1254

1224 1295
1254

1364 1435
1394

1394

48 M16

110 100

48 M16
55 M20

110 100
110 100

55 M20

110 100

60
55
60
60
65
65
75
65
75
65
80
65
80
65
80
80

M20

140
110
140
140

M20

140 125

M20

140 125

M20

140
170
140
170
140
170
170

M20
M20

M20
M20

125
100
125
125

125
140
125
140
125
140
140

GA

NDE shaft extension


DA DC EA EC EE FA GC

5 14 51.5 48 M16 110 100


5 14 51.5 48 M16
5 16 59
48 M16
55 M20
5 16 59
48 M16
55 M20
10 18 64
55 M20
5 16 59
48 M16
10 18 64
55 M20
10 18 64
55 M20
69
60
10 18 69
60 M20
20 79.5 65
10 18 69
60 M20
20 79.5 65
10 18 69
60 M20
22 85
70
10 18 69
60 M20
22 85
70
10 18 69
60 M20
22 85
70
22 85
70

110 100
110 100
110 100
110 100
110 100
100
110 100
140 125
140 125
140 125
140 125
140 125
140 125

Siemens D 81.1 2007

5 14 51.5
5 14 51.5
5 14 51.5
16 59
5 14 51.5
16 59
10 16 59
5 14 51.5
10 16 59
5 16 59
18 64
10 18 64
69
10 18 64
69
10 18 64
20 74.5
10 18 64
20 74.5
10 18 64
20 74.5
20 74.5

4/129

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MJ6, frame sizes 71 M to 160 L
Type of construction IM B3
Eyebolts from
size 100 L

G_D081_EN_00019

LC
L
LF
LL
BE

AG
AS

FA

AQ

AC

DA

BC

GA

GC

DB

EC
EB

DC

ED
K
C

EE
EA

CA

AD

K'

HA

A
AA

BA

AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
Eyebolts from
size 100 L

G_D081_EN_00020

LC
L
LF
LL
HH
BE

AG
AS

ED

AF
AD

LM

EB

GC

EC

DC

DB

For motor
Frame Type
size
71 M 1MJ6 070
1MJ6 073
80 M 1MJ6 080
1MJ6 083
90 L
1MJ6 096
1MJ6 097
100 L 1MJ6 106
1MJ6 107
112 M 1MJ6 113
132 S 1MJ6 130
1MJ6 131
132 M 1MJ6 133
1MJ6 134
160 M 1MJ6 163
1MJ6 164
160 L 1MJ6 166

Number
of poles
2, 4
2, 4, 6
2, 4, 6
2, 4, 6
2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

Dimension designation acc. to IEC


A
AA AB AC1) AD
AF
112 34

AG

AQ AS B

140 148.5 2012) 162 152 124 71


2)

BA BB

BC BE C

CA

HA

HH

K'

10

299

90 30

110 58

54

45 144

71

103

9.5 13.5 336

125 36

160 165.5 209

170 152 125 71

100 35

125 44

54

50 156

80 10

93.5

140 37

168 183

218

177 162 170 81

125 35

156 54

54

56 177

90 13

109.5 10

14

383

160 45

196 202.5 223

182 162 170 81

140 45

176 50

54

63 185 100 14

112.5 12

16

426

190 50
216 53

226 228.5 238


256 267.5 258

197 162 170 81


217 162 250 81

140 45
140 49

176 52
180 55

54
54

70 180 112 15
89 228 132 17

121.5 12
144
12

16
16

428
515

216 53

256 267.5 258

217 162 250 81

178 49

218 55

54

89 190 132 17

144

12

16

515

254 60

300 323

280

239 162 250 81

210 57

256 40

54

108 238 160 20

148

15

19

641

254 60

300 323

314

246 216 250 95

254 57

300 40

96

108 194 160 20

148

15

19

641

1)

Measured across the bolt heads.

2)

K09 and K10 frame size 90 and above.

4/130

AQ

AC

D
GA

FA

EE

DA

EA
E

AF
AD

LM

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MJ6, frame sizes 71 M to 160 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
Eyebolts from
size 100 L

G_D081_EN_00021

LC
L
LF
LL
BE

AG
AS

ED
AF
AD

LM

AQ

EC

EB
DB

GC

GA

FA

AC

DA

BC
E

DC
K

EE
CA

K'

HA

EA

AD
A

AA

BA

AB

BB

Type of construction IM B14 only for frame sizes 71 M to 90 L


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
Eyebolts frame size
100 L and above

G_D081_EN_00022

LC
L
LL
BE

AG
AS

ED

AF
AD

LM

EB

DC

For motor
Frame Type
size
71 M 1MJ6 070
1MJ6 073
80 M 1MJ6 080
1MJ6 083
90 L
1MJ6 096
1MJ6 097
100 L 1MJ6 106
1MJ6 107
112 M 1MJ6 113
132 S 1MJ6 130
1MJ6 131
132 M 1MJ6 133
1MJ6 134
160 M 1MJ6 163
1MJ6 164
160 L 1MJ6 166

GC

EC

DB

AQ

AC

F
GA

FA

EE

DA

EA
E

Number
of poles
2, 4
2, 4, 6
2, 4, 6
2, 4, 6
2, 4, 6, 8
2, 4, 6, 8
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

Dimension designation acc. DE shaft extension


to IEC
LC
LF
LL
LM
D
DB
E
EB

NDE shaft extension


ED

GA

DA

DC

EA

EC

EE

FA

GC

339

132

327

14

M5

30

22

16

14

M5

30

22

16

386

132

362

19

M6

40

32

21.5

19

M6

40

32

21.5

458

162

434.5

24

M8

50

40

27

24

M8

50

40

27

508

162

477.5

28

M10

60

50

31

28

M10

60

50

31

510
617

162
162

479.5
567.5

28
38

M10
M12

60
80

50
70

5
5

8
10

31
41

28
38

M10
M12

60
80

50
70

5
5

8
10

31
41

617

162

567.5

38

M12

80

70

10

41

38

M12

80

70

10

41

776

383

162

693.5

42

M16

110

90

10

12

45

42

M16

110

90

10

12

45

776

383

190

693.5

42

M16

110

90

10

12

45

42

M16

110

90

10

12

45

Siemens D 81.1 2007

4/131

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MJ6 and 1MJ7, frame sizes 180 M to 315 M
Type of construction IM B3
AG
AS

GC

K
CA

DB
C

B
BA

BC

HA

GA

AQ

AC

EC

AF
AD

LM,
LM'

FA

BE

EB

EE

DA

ED

G_D081_XX_00011

LC
L, L'
LL

DC

K'

EA

AF'
A

BA'

AA

Frame sizes 180 M/L, 225 S/M,


280 S/M and 315 S/M have frame
feet each with 2 drilled holes at NDE.

BB

AA
AD'
AB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)

GC
AH

GA

AQ

AC

EC

AG

AF
AD

BE
EB

AS

LM,
LM'

FA

EE

DA

LL

ED

Type of construction IM B5 / IM V1
(only up to frame size 315 M)

G_D081_XX_00012

LC
L, L'

DB

EA

DC

HH

The motors are supplied with two fitted eyebolts conforming to IM B5,
whereby one can be repositioned to conform to IM V1 or IM V3. It is important
to note that stress must not be applied perpendicular to the ring plane.

For motor
Frame Type
size
180 M 1MJ6 183
180 L 1MJ6 186
200 L 1MJ6 206
1MJ6 207
225 S 1MJ7 220
225 M 1MJ7 223
250 M 1MJ7 253
280 S

1MJ7 280

280 M 1MJ7 283


315 S

1MJ7 310

315 M 1MJ7 313

*
1)

Number
of poles
2, 4
4, 6, 8
2
6
2
4, 6, 8
4, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

B*

BA

BA' BB

BC BE C

CA*

HH HA

279
279
318

65 344 375
65 344 375
80 398 415

306 306 259 259 220 470 340


306 306 259 259 220 470 340
349 349 289 289 262 530 340

82 241
82 279
98.5 305

70 108 319 35
70 108 319 35
85 85 355 42

75
75
85

121 259
121 221
133 239

180 156 26
180 156 26
200 175 34

318

80 398 415

349 349 289 289 262 530 340

98.5 305

85

85 355 42

85

133 239

200 175 34

356
356

80 436 442
80 436 442

377 377 315 315 262 580 425 100


377 377 315 315 262 580 425 100

286
311

85 110 361 25
85 110 361 25

90
90

149 269
149 244

225 174 34
225 174 34

406 100 506 505

466 466 353 353 336 645 470 120

349 100 100 409 39

95

168 283

250 207 42

457 100 557 555

491 491 395 395 336 700 525 120

368 100 151 479 30

95

190 317

280 220 42

457 100 557 555

491 491 395 395 336 700 525 120

419 100 151 479 30

95

190 266

280 220 42

508 120 628 620

558 558 448 448 410 805 590 135

406 125 171 527 32

90

216 358

315 248 56

508 120 628 620

558 558 448 448 410 805 590 135

457 125 171 527 32

90

216 307

315 248 56

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

4/132

AF' AG AH AQ AS

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1MJ6 and 1MJ7, frame sizes 180 M to 315 M
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
Eyebolts from
size 100 L

G_D081_EN_00024

BC

AF
AD

GC

EE

DB

K
CA

K'

DC

AF'
A

EA

BA'

BA

E
ED

HA

AC

AQ

EC

LM

DA

BE
EB

AG
AS

FA

LC
L, L'
LL

AD'
AA

AA

BB

AB

For motor
Frame Type
size
180 M 1MJ6 183
180 L 1MJ6 186
200 L 1MJ6 206
1MJ6 207
225 S 1MJ7 220
225 M 1MJ7 223
250 M 1MJ7 253
280 S

1MJ7 280

280 M 1MJ7 283


315 S

1MJ7 310

315 M 1MJ7 313

Number
of poles
2, 4
4, 6, 8
2
6
2
4, 6, 8
4, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8
2
4, 6, 8

Dimension designation acc. to IEC


K
K' L
L'1) LC2) LL LM

DE shaft extension
LM'1) D DB E
EB

ED F

15
15
19

20
20
25

19

25

19
19

25
25

24

30

885

910

910

955

1110

1230

1230

1295

1295

5 14 51.5 48
5 14 51.5 48
5 16 59
48
55
5 16 59
48
55
10 18 64
55
5 16 59
48
10 18 64
55
10 18 64
55
69
60
10 18 69
60
20 79.5 65
10 18 69
60
20 79.5 65
10 18 69
60
22 85
70
10 18 69
60
22 85
70

24

30

24

30

28

35

28

35

715
715
771.5

770

825

771.5 825

839

809
855
839

930 1010

1010 1080

1010 1080

1114 1185
1140

1114 1185
1140

841 164
841 164
897 197

796.5
796.5
853

897 197

853

954
924
954
1050
1080
1155

197
197

939
909
939
234 1035
234 1120

1155 234 1120


1260 266 1224
1290
1250
1260 266 1224
1290
1250

1)

For version with low-noise fan.

2)

In the low-noise version, a second shaft extension is not possible.

48 M16 110 100


48 M16 110 100
55 M20 110 100
55 M20 110 100
60
55
60
60
65
65
75
65
75
65
80
65
80

M20 140 125


M20 110 100
140 125
M20 140 125
M20 140 125
M20 140 125
M20 140
170
M20 140
170

125
140
125
140

GA

NDE shaft extension


DA DC EA EC EE FA GC
M16
M16
M16
M20
M16
M20
M20
M16
M20
M20

110 100
110 100
110 100
110 100
110 100
110 100

110 100
140 125
M20 140 125
M20 140 125
M20 140 125
M20 140 125

Siemens D 81.1 2007

5 14 51.5
5 14 51.5
5 14 51.5
16 59
5 14 51.5
16 59
5 16 59
5 14 51.5
16 59
5 16 59
10 18 64
10 18 64
69
10 18 64
69
10 18 64
20 74.5
10 18 64
20 74.5

4/133

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1LA7 and 1LA5, frame sizes 56 M to 225 M
Type of construction IM B3
G_D081_EN_00001

ED

AG
AS

BC

GC

EC

EB
DB

Frame sizes 90 S/L


and 225 S/M have
frame feet with
2 drilled holes at NDE.

AQ

BE

GA

FA

AC

BE'

Eyebolts frame size


100 L and above

LM

DA

EE

AF
AD

LC
L
LL

DC

CA

K'

HA

K
E

EA

BA

AF'

CA

BA

BB

AD'

AA

BA'

AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)

G_D081_EN_00002

LL

DB

AQ
GC

DC

EE
EA

Dimension designation acc. to IEC

Frame Type
size
56 M2) 1LA7 050
1LA7 053
63 M 1LA7 060
1LA7 063
71 M 1LA7 070
1LA7 073
80 M 1LA7 080
1LA7 083
90 S 1LA7 090
90 L 1LA7 096
100 L 1LA7 106
1LA7 107
112 M 1LA7 113
132 S 1LA7 130
1LA7 131
132 M 1LA7 133
1LA7 134
160 M 1LA7 163
1LA7 164
160 L 1LA7 166
180 M 1LA5 183
180 L 1LA5 186
200 L 1LA5 206
1LA5 207
225 S 1LA5 220
225 M 1LA5 223

1)

EC

ED

For motor

FA
AC

D
E

GA

AA

BC

BE

BE'

90

25

110 116

135 135

95

95 120

87 56

32

18

36

53

56

2, 4, 6

100

27

120 124

135 135

95

80 28

96 52

32

18

40

66

63

2, 4, 6, 8 112

27

132 145

90 27

106 41

32

18

45

83

71

2, 4, 6, 8 125

30.5 150 163

154 154 114 114 120 124 37.5 100 32

118 36

32

18

50

94

80

2, 4, 6, 8 140

30.5 165 180

54

143 45.5 32

18

2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8
2, 4
4, 6, 8
2, 6
2, 4, 6, 8
4, 8
2
4, 6, 8

160

42

196 203

162 162 122 122 120 170 37.5 100 33


125
135 163 78 123 120 170 60
140 47

176 39

42

21

56 143
118
63 125

190
216

46
53

226 227
256 267

148 176 91 136 120 170 60


167 194 107 154 140 250 70

140 47
140 49

176 32
180 39

42
42

21
21

70 141 112 12
89 162.5 132 15

216

53

256 267

167 194 107 154 140 250 70

178 49

218 39

42

21

89 124.5 132 15

254

60

300 320

197 226 127 183 165 250 82.5 210 57

256 52.5 54

27

108 183

160 18

254
279
279
318

60
69.5
69.5
83

300
339
339
388

197
258
258
305

300
287
325
355

54
54
54
85

27
27
27
42.5

108
121
121
133

160
180
180
200

83
83

361 36
361 36

85
85

42.5 149 248.5 225 24


42.5 149 223.5 225 24

356 103
356 103

AB

AC1) AD

Number
of poles
2, 4

320
363
363
402

426 402
426 402

AD' AF

AQ

AS

37

71 28

95 120 124 37

145 145 105 105 120 124 37

226
258
258
305

127
216
216
252

Siemens D 81.1 2007

AF' AG

183
216
216
252

165
152
152
260

250
340
340
340

82.5
71
71
96

305 305 252 252 260 340 96


305 305 252 252 260 340 96

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

4/134

Eyebolts frame size


100 L and above

LM

DA

BE'
BE

EB

AG
AS

AF
AD

LC
L
HH

2)

B*

254
241
279
305

BA

57
50
50
58.5

286 58
311 58

BA' BB

52.5
38
38
45

The motors of frame size 56 M are not ventilated.

CA*

139
259
221
239

HA

90 10
100 12

18
18
18
24

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1LA7 and 1LA5, frame sizes 56 M to 225 M
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00003

BC

EC

DB

GC

DC

K
ED

EE

CA

BA

A
AA

BA

CA

AF'

K'

HA

GA

AC

BE

Frame sizes 90 S/L


and 225 S/M have
frame feet with
2 drilled holes at NDE.

AQ

EA

FA

BE'

Eyebolts frame size


100 L and above

LM

DA

EB

AG
AS

AF
AD

LC
L
LL

BA'
BB

AD'
AB

BB

Type of construction IM B14


Type of construction IM B14 not possible for 1LA5 motors, frame sizes 180 M to 225 M
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00004

LL

AC

AQ

FA

EA

Eyebolts frame size


100 L and above

LM

DA

BE'
BE

EB

AG
AS

AF
AD

LC
L

HH

GA

EC

GC
DC

DB

ED

For motor
Frame Type
size
56 M1) 1LA7 050
1LA7 053
63 M 1LA7 060
1LA7 063
71 M 1LA7 070
1LA7 073
80 M 1LA7 080
1LA7 083
90 S
1LA7 090
90 L
1LA7 096
100 L
1LA7 106
1LA7 107
112 M 1LA7 113
132 S
1LA7 130
1LA7 131
132 M 1LA7 133
1LA7 134
160 M 1LA7 163
1LA7 164
160 L
1LA7 166
180 M 1LA5 183
180 L
1LA5 186
200 L
1LA5 206
1LA5 207
225 S
1LA5 220
225 M 1LA5 223

Number
of poles
2, 4

EE

Dimension designation acc. to IEC


HH
K
K'
L
LC
LL
69.5

5.8

169

2, 4, 6

69.5

10

2, 4, 6, 8

63.5

10

2, 4, 6, 8

63.5

9.5 13.5 273.5

2, 4, 6, 8

79

10

14

2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8
2, 4
4, 6, 8
2, 6
2, 4, 6, 8
4, 8
2
4, 6, 8

102

12

102
128
128

200

DE shaft extension
LM

DB

EB

NDE shaft extension


ED

GA DA DC EA

EC

EE

FA GC

120

M3

20

14

10.2 9

M3

20

14

3 10.2

202.52) 2322)

120

231.52) 11

M4

23

16

3.5

12.5 11

M4

23

16

3.5

4 12.5

240

278

120

268

14

M5

30

22

16

14

M5

30

22

5 16

120

299.5

19

M6

40

32

21.5 19

M6

40

32

6 21.5

331

324
364
389

120

382.5

24

M8

50

40

27

19

M6

40

32

6 21.5

16

372

438

120

423.5

28

M10

60

50

31

24

M8

50

40

8 27

12
12

16
16

393
461
120
452.53) 551.5 140

444.5
5053)

28
38

M10
M12

60
80

50
70

5
5

8
10

31
41

24
38

M8
50
M12 80

40
70

5
5

8 27
10 41

12

16

452.53) 551.5 140

5053)

38

M12

80

70

10

41

38

M12 80

70

10 41

160.5 15

19

588

721

165

640.5

42

M16 110

90 10

12

45

42

M16 110

90 10

12 45

160.5
159
159
178

15
15
15
19

19
19
19
25

588
712
712
769.5

721
841
841
897

165
132
132
192

640.5
793.5
793.5
850

42
48
48
55

M16
M16
M16
M20

110 90 10
110 100 5
110 100 5
110 100 5

12
14
14
16

45
51.5
51.5
59

42
48
48
55

M16
M16
M16
M20

184.5 19
184.5 19

25
25

806
776
806

933.5 192
903.5 192
933.5

887.5
857.5
887.5

60
55
60

M20 140 125


M20 110 100
M20 140 125

64
59
64

55
55

M20 110 100


M20 110 100

1)

The motors of frame size 56 M are not ventilated.

2)

For 1LA7 063 with type of construction code 1 (B5, IM V1 without protective cover, IM V3) the dimensions L, LC and LM are 26 mm longer.

3)

7.5 18
5 16
7.5 18

110 90 10
110 100 5
110 100 5
110 100 5
5
5

12
14
14
16

45
51.5
51.5
59

16 59
16 59

In a low-noise version, the dimension L is 8 mm greater and the


dimension LM is 11.5 mm greater.

Siemens D 81.1 2007

4/135

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1LA9, frame sizes 56 M to 200 L
Type of construction IM B3
G_D081_EN_00001

ED

AG
AS

BC

GC

EC

EB
DB

Frame size 90 S/L has


frame feet each with
2 drilled holes at NDE.

AQ

BE

GA

FA

AC

BE'

Eyebolts frame size


100 L and above

LM

DA

EE

AF
AD

LC
L
LL

DC

CA

K'

HA

K
E

EA

BA

AF'

CA

BA

BB

AD'

AA

BA'

AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)

G_D081_EN_00005

EE

LL

DB

112 M
132 S
132 M

160 M
160 L
180 M
180 L
200 L

AQ

EC

GC

EA

DC

ED

For motor
Frame Type
size
56 M2) 1LA9 050
1LA9 053
63 M 1LA9 060
1LA9 063
71 M 1LA9 070
1LA9 073
80 M 1LA9 080
1LA9 083
90 S
1LA9 090
90 L
1LA9 096
100 L

FA
AC

GA

1LA9 106
1LA9 107
1LA9 113
1LA9 130
1LA9 131
1LA9 133
1LA9 133
1LA9 134
1LA9 163
1LA9 164
1LA9 166
1LA9 183
1LA9 186
1LA9 206
1LA9 207

Dimension designation acc. to IEC


Number A
AA AB AC1) AD AD' AF
of poles
2, 4
90 25
110 116 135 135 95

AQ AS

B*

BA

BA' BB

BC

BE BE' C

CA*

HA

95

120

37

71

28

87 56

32

18

36

53

56

95

66
92
83

63

71

80

90

10

100

12

112
132

12
15

132

15

120 124 37

80

28

96 52

32

18

40

2, 4

112 30.5 132 145 145 145 105 105 120 124 37

90

27

106 41

32

18

45

2, 4

125 30.5 150 163 154 154 114 114 120 124 37.5 100 32

118 36

32

18

50

2, 4, 6

140 30.5 165 180 162 162 122 122 120 170 37.5 100 33
125

54

143 45.5

32

18

2, 4, 6

160 42

196 203 135 163

123 120 170 60

140 47

176 39

42

21

2, 4, 6
2, 4
2
6
4
6
2, 4, 6
2
2, 4, 6
2, 4
4, 6
2, 6
2, 4, 6

190 46
216 53

226 227 148 176 91 136 120 170 60


256 267 167 194 107 154 140 250 70

140 47
140 49

176 32
180 39

42
42

21
21

216 53

256 267 167 194 107 154 140 250 70

178 49

218 39

42

21

254 60

300 320 197 226 127 183 165 250 82.5 210 57

256 52.5

54

27

108 183

160

18

254
279
279
318

300
339
339
388

300
287
325
355

54
54
54
85

27
27
27
42.5

108
121
121
133

160
180
180
200

18
18
18
24

320
363
363
402

197
258
258
305

226
258
258
305

95

AG

100 27

60
69.5
69.5
83

120 124 135 135

AF'

2, 4

78

127
216
216
252

This dimension is assigned in DIN EN 50347 to the frame size listed.

4/136

Eyebolts frame size


100 L and above

LM

DA

BE'
BE

EB

AG
AS

AF
AD

LC
L
HH

Siemens D 81.1 2007

183
216
216
252

165
152
152
260

250
340
340
340

82.5
71
71
96

254
241
279
305

57
50
50
58.5

52.5
38
38
45

94
134
56 143
118

63 160
1953)
70 179
89 162.5
200.5
89 124.5
162.5

179
259
221
239

1)

Measured across the bolt heads.

2)

The motors of frame size 56 M are not ventilated. Frame size 56 M is not
available in IM B35.

3)

For 1LA9 107-4KA.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Aluminum series 1LA9, frame sizes 56 M to 200 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00006

BC

EC

DB

DC

K
ED

EE

CA

GC

BA

A
AA

BA

CA

AF'

K'

HA

GA

AC

BE
E

Frame size 90 S/L has


frame feet each with
2 drilled holes at NDE.

AQ

EA

FA

BE'

Eyebolts frame size


100 L and above

LM

DA

EB

AG
AS

AF
AD

LC
L
LL

BA'
BB

AD'
AB

BB

Type of construction IM B14


Type of construction IM B14 not possible for 1LA9 motors, frame sizes 180 M to 200 L
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_EN_00004

L
LL

AC

AQ

FA

EA

Eyebolts frame size


100 L and above

LM

DA

BE'
BE

EB

AG
AS

AF
AD

LC
HH

GA

EC

GC
DC

DB

For motor
Frame Type
size
56 M1) 1LA9 050
1LA9 053
63 M 1LA9 060
1LA9 063
71 M 1LA9 070
1LA9 073
80 M 1LA9 080
1LA9 083
90 S
1LA9 090
90 L
1LA9 096
100 L
112 M
132 S
132 M

160 M
160 L
180 M
180 L
200 L

1LA9 106
1LA9 107
1LA9 113
1LA9 130
1LA9 131
1LA9 133
1LA9 133
1LA9 134
1LA9 163
1LA9 164
1LA9 166
1LA9 183
1LA9 186
1LA9 206
1LA9 207

ED

EE

Dimension designation acc. to IEC


Number HH
K
K'
L
LC
LL
of poles
2, 4
69.5 5.8 9
1692) 2002) 120
2, 4

69.5

10

2, 4

63.5

10

2, 4

63.5

2, 4, 6

79

2, 4, 6

102

2, 4, 6
2, 4
2
6
4
6
2, 4, 6
2
2, 4, 6
2, 4
4, 6
2, 6
2, 4, 6

102
128
128

202.5
228.5
240

9.5 13.5 273.5


308.5
10
14
331
3764)
3585)
12
16
407
4426)
12
16
431
12
16
452.5
490.5
12
16
452.5
490.5

3)

232
258
278

3)

324
364
389
4344)
4145)
473
5086)
499
551.5
589.5
551.5
589.5

120
120
120
120

120
120
140
140

LM

DE shaft extension
D
DB E
EB

231.5
257.5
268
299.5
334.5
382.5
427.54)
409.55)
458.5
4936)
482.5
505
543
505
543

NDE shaft extension


GA DA DC EA EC EE

FA GC

M3

20

14

10.2 9

M3

20

14

3 10.2

11

M4

23

16

3.5

12.5 11

M4

23

16

3.5

4 12.5

14

M5

30

22

16

14

M5

30

22

5 16

19

M6

40

32

21.5 19

M6

40

32

6 21.5

24

M8

50

40

27

19

M6

40

32

6 21.5

28

M10

60

50

31

24

M8

50

40

8 27

28
38

M10
M12

60
80

50
70

5
5

8
10

31
41

24
38

M8
50
M12 80

40
70

5
5

8 27
10 41

38

M12

80

70

10

41

38

M12 80

70

10 41

90 10

12

45

42

M16 110

90 10

12 45

110 90 10
110 100 5
110 100 5
110 100 5

12
14
14
16

45
51.5
51.5
59

42
48
48
55

M16
M16
M16
M20

160.5 15

19

588

721

165

640.5

42

M16 110

160.5
159
159
178

19
19
19
25

628
712
712
768.5

761
841
841
897

165
132
132
192

680.5
793.5
793.5
850

42
48
48
55

M16
M16
M16
M20

15
15
15
19

ED

110 90 10
110 100 5
110 100 5
110 100 5

12
14
14
16

45
51.5
51.5
59

1)

The motors of frame size 56 M are not ventilated. Frame size 56 M is not
available in IM B35.

3)

For 1LA9 060 with type of construction code 1 (B5, IM V1 without protective cover, IM V3) the dimensions L, LC and LM are 26 mm longer.

2)

For 1LA9 frame size 56 M with type of construction code 1 (B5, IM V1


without protective cover, IM V3) the dimensions L, LC and LM are
26 mm longer.

4)

For 1LA9 096-6KA.

5)

For 1LA9 096-2 and 1LA9 096-4.

6)

For 1LA9 107-4KA.

Siemens D 81.1 2007

4/137

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LA6, frame sizes 100 L to 160 L
Type of construction IM B3

AQ

AC

BC

GC

EC

EB
DB

FA

BE'

AF
AD

LM

BE

GA

EE

AG
AS

DA

ED

G_D081_XX_00007

LC
L
LL

DC

CA

K'

HA

K
E

EA

BA

AF'
A
AD'

AA
AB

BB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00008

EE

DC

AF'
AD

ED

For motor
Frame Type
size
100 L 1LA6 106
1LA6 107
112 M 1LA6 113
132 S 1LA6 130
1LA6 131
132 M 1LA6 133
1LA6 134
160 M 1LA6 163
1LA6 164
160 L 1LA6 166

Number
of poles
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AF'

AG

AQ

AS

160 40

196 201

BA

BB

BC

BE BE' C

CA

HA

164

164

124

124

121

170

60.5 140 46

180 42

44

22

63 125

100 12

190 42.5 226 225.5 178


216 50
256 265 194

178
194

138
154

138
154

121
141

170
250

60.5 140 46
70.5 140 47

180 34
180 42

44
44

22
22

70 141
89 162.5

112 15
132 17

216 50

194

154

154

141

250

70.5 178 49

218 42

44

22

89 124.5

132 17

256 265

194

254 60

300 320

226

226

183

183

166

250

83

210 63

256 52

54

27

108 183

160 18

254 60

300 320

226

226

183

183

166

250

83

254 63

300 52

54

27

108 139

160 18

Measured across the bolt heads.

4/138

GC

EC

EA

1)

AQ

AC

BE

GA

DB

LM

DA

BE'
EB

AG
AS

FA

LL

AF
AD

LC
L
HH

Siemens D 81.1 2007

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LA6, frame sizes 100 L to 160 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00009

BC

EC

AC

DB

GC

DC

K
ED

EE

CA

AF'

K'

HA

GA

AQ

EA

BE

FA

BE'

LM

DA

EB

AG
AS

AF
AD

LC
L
LL

A
AA

BA

AD'
AB

BB

Types of construction IM B14


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00010

AQ

AC

EA

LM

FA

BE'
BE

EB

AG
AS

DA

LL

AF
AD

LC
L
HH

GA

GC

EC
DC

DB

For motor
Frame Type
size
100 L 1LA6 106
1LA6 107
112 M 1LA6 113
132 S 1LA6 130
1LA6 131
132 M 1LA6 133
1LA6 134
160 M 1LA6 163
1LA6 164
160 L 1LA6 166

ED

Number
of poles
2, 4, 6, 8
4, 8
2, 4, 6, 8
2, 4, 6, 8
2
4, 6, 8
6
2, 4, 6, 8
2, 8
2, 4, 6, 8

EE

Dimension designation acc. to IEC


HH
K
K' L
LC
LL

LM

104.5 12

16

372

121

423.5 28

M10

60

50

31

24

M8

50

104.5 12
130.5 12

16
16

393
461
121
453.5 551.5 141

444.5 28
506
38

M10
M12

60
80

50
70

5
5

8
10

31
41

24
38

M8
M12

130.5 12

16

453.5 551.5 141

506

M12

80

70

10

41

38

M12

438

DE shaft extension
D
DB E
EB

38

ED

NDE shaft extension


GA DA DC EA EC

EE

FA

GC

40

27

50
80

40
70

5
5

8
10

27
41

80

70

10

41

160

14.5 18

588

721

166

640.5 42

M16 110 90

10

12

45

42

M16 110 90

10

12

45

160

14.5 18

588

721

166

640.5 42

M16 110 90

10

12

45

42

M16 110 90

10

12

45

Siemens D 81.1 2007

4/139

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG4, frame sizes 180 M to 315 L
Type of construction IM B3
G_D081_XX_00014

EC

AF
AD

GC

BC

DB
E

CA

BA

Frame sizes 180 M/L, 225 S/M,


280 S/M and 315 S/M/L have
frame feet each with 2 drilled
holes at NDE.

DC

HA

GA

AQ

AC

DA

BE

EB

LM,
LM'

FA

EE

ED

AG
AS

LC
L, L'
LL

EA

BA'
BB

AF'

K'
A

AA
AD'

AA
AB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00012

LC

LM,
LM'

AQ

AC

EC

GC
AH

GA

AG

AF
AD

BE
EB

AS

FA

EE

DA

L, L'
LL

ED

DB
HH

For motor
Frame Type
size
180 M 1LG4 183
180 L
1LG4 186
1LG4 188
200 L
1LG4 206
1LG4 207
1LG4 208

Number
of poles
2, 4
4, 6, 8
2, 4, 6, 8
2, 6
2, 4, 6, 8
2, 6
4, 8
225 S
1LG4 220
4, 8
225 M 1LG4 223
2
4, 6, 8
1LG4 228
2
4, 6, 8
250 M 1LG4 253
2
4, 6, 8
1LG4 258
2
4
6, 8
280 S
1LG4 280
2
4, 6, 8
280 M 1LG4 283
2
4, 6, 8
1LG4 288
2
4
6, 8
315 S
1LG4 310
2
1LG4 310
4, 6, 8
315 M 2) 1LG4 313
2
1LG4 313
4, 6, 8
2)
315 L
1LG4 316/317 2
1LG4 316/317 4, 6, 8
1LG4 318
8
1LG4 318
6
*
1)

DC
EA
The motors are supplied with two fitted eyebolts conforming to IM B5,
whereby one can be repositioned to conform to IM V1 or IM V3. It is important
to note that stress must not be applied perpendicular to the ring plane.

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AF'

AG

AH

AQ

279
279
279
318
318
318

65
65
65
70
70
70

220
220
220
247
247
247

152
152
152
260
260
260

452
452
452
512
512
512

340
340
340
340
340
340

356
356
356

339
339
339
378
378
378

363
363
363
402
402
402

262
262
262
300
300
300

262
262
262
300
300
300

220
220
220
247
247
247

71
71
71
96
96
96

B*

BA

BA'

BB

BC BE

C
121
121
121
133
133
133

CA* H
180
180
180
200
200
200

HA

241
279
279
305
305
305

70 111 328 36
70 111 328 36
70 111 328 36
80 80 355 63
80 80 355 63
80 80 355 63

54
54
54
85
85
85

80 436 442 325 325 272 272 260 556 425


80 436 442 325 325 272 272 260 556 425

96 286
96 311

85 110 361 47
85 110 361 47

85
85

202
164
215
177
177
234
177
149 218
149 193

80 436 442 325 325 272 272 260 556 425

96 311

85 110 361 47

85

149 253 225 34

20
20
20
25
25
25

225 34
225 34

406 100 490 495 392 392 308 308 300 620 470 118 349 100 100 409 69

110 168 235 250 40

406 100 490 495 392 392 308 308 300 620 470 118 349 100 100 409 69

457 100 540 555 432 432 348 348 300 672 525 118 368 100 151 479 62

110 168 235 250 40


305
235
110 190 267 280 40

457 100 540 555 432 432 348 348 300 672 525 118 419 100 151 479 62

110 190 216 280 40

457 100 540 555 432 432 348 348 300 672 525 118 419 100 151 479 62

110 190 326 280 40

508 120 610 610 500 500 400 400 380 780 590 154 406 125 176 527 69

216
110 216 315 315 50

508 120 610 610 500 500 400 400 380 780 590 154 457 125 176 527 69

110 216 264 315 50

508 120 610 610 500 500 400 400 380 780 590 154 508 125 176 578 69

110 216 373 315 50

508 120 610 610 500 500 400 400 380 780 590 154 508 155 206 648 69

110 216 513 315 50

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

4/140

AS

Siemens D 81.1 2007

2)

With order codes for connection box positions (K09, K10, K11) only fitted
feet with 3 drilled holes with dimension B (406, 457 and 508 mm).
BB will then be 666 mm.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG4, frame sizes 180 M to 315 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00013

ED

BC

GC

DB
B

CA

BA

EE
EA

HA

AQ

AC

FA

EC

GA

LM,
LM

DA

BE
EB

AG
AS

AF
AD

LL

LC
L, L'

K'

DC

AF'
A

AA

BA'

AA
AD'

BB
AB

For motor
Frame Type
size
180 M 1LG4 183
180 L
1LG4 186
1LG4 188
200 L
1LG4 206
1LG4 207
1LG4 208

Number
of poles
2, 4
4, 6, 8
2, 4, 6, 8
2, 6
2, 4, 6, 8
2, 6
4, 8
225 S
1LG4 220
4, 8
225 M 1LG4 223
2
4, 6, 8
1LG4 228
2
4, 6, 8
250 M 1LG4 253
2
4, 6, 8
1LG4 258
2
4
6, 8
280 S
1LG4 280
2
4, 6, 8
280 M 1LG4 283
2
4, 6, 8
1LG4 288
2
4
6, 8
315 S
1LG4 310
2
1LG4 310
4, 6, 8
315 M 3) 1LG4 313
2
1LG4 313
4, 6, 8
315 L3) 1LG4 316/317 2
1LG4 316/317 4, 6, 8
1LG4 318
8
1LG4 318
6

Dimension designation acc. to IEC


HH K K' L
L'1)
LC2) LL
157
157
157
196
196
196

15
15
15
19
19
19

19
19
19
25
25
25

196 19 25
196 19 25
196 19 25
237 24 30
237 24 30

669
669
720
720
720
777
720
789
759
789
819
849
887

252 24 30

887
957
887
960

252 24 30

960

252 24 30 1070
960
285 28 35 1072
1102
285 28 35 1072
1102
285 28 35 1232
1262
285 28 35 1402

669

720
754
754
811

793

853

924

924

998

998

1108

1142

1142

1302

784
784
835
835
835
892
835
903
873
903
933
963
1002
1032
1002
1102
1032
1105

132
132
132
192
192
192
192
192
192
236
236

236

1105 236
1215 236
1105
1217 307
1247
1217 307
1247
1377 307
1407
1547 307

1)

For version with low-noise fan for 2-pole motors.

2)

In the low-noise version, a second shaft extension is not possible.

LM

DE shaft extension
LM'1) D DB
E
EB ED F

759 759
759
810 810
810 844
810 844
867 901
810
889
859 893
889
919 953
949
987 1024

987 1024
1057
987
1070 1108

1070 1108

1180 1218

1070
1182 1252
1212
1182 1252
1212
1342 1412
1372

1512
3)

GA

NDE shaft extension


DA DC EA EC EE FA GC

48
48
48
55
55
55

M16
M16
M16
M20
M20
M20

110
110
110
110
110
110

100
100
100
100
100
100

5
5
5
5
5
5

14
14
14
16
16
16

51.5
51.5
51.5
59
59
59

48
48
48
55
55
55

M16
M16
M16
M20
M20
M20

110
110
110
110
110
110

100
100
100
100
100
100

5
5
5
5
5
5

14
14
14
16
16
16

51.5
51.5
51.5
59
59
59

60
55
60
55
60
60
65
60
65
65
65
75
65
75
65
75
75
65
80
65
80
65
80
80
80

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

140
110
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
170
140
170
140
170
170
170

125
100
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
140
125
140
125
140
140
140

10
5
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
25
10
25
10
25
25
25

18
16
18
16
18
18
18
18
18
18
18
20
18
20
18
20
20
18
22
18
22
18
22
22
22

64
59
64
59
64
64
69
64
69
69
69
79.5
69
79.5
69
79.5
79.5
69
85
69
85
69
85
85
85

55
48
55
48
55
55
60
55
60
60
60
65
60
65
60
65
65
60
70
60
70
60
70
70
70

M20
M16
M20
M16
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

110
110
110
110
110
110
140
110
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140

100
100
100
100
100
100
125
100
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

5
5
5
5
5
5
10
5
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

16
14
16
14
16
16
18
16
18
18
18
18
18
18
18
18
18
18
20
18
20
18
20
20
20

59
51.5
59
51.5
59
59
64
59
64
64
64
69
64
69
64
69
69
64
74.5
64
74.5
64
74.5
74.5
74.5

With order codes for connection box positions (K09, K10, K11) only fitted feet with 3 drilled holes with dimension B (406, 457 and 508 mm).
BB will then be 666 mm.

Siemens D 81.1 2007

4/141

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG6, frame sizes 180 M to 250 M
Type of construction IM B3
G_D081_XX_00014

AF
AD

GC

BC

DB
C

DC

CA

BA

HA

GA

AQ

AC

EC

FA

BE

EB

LM,
LM'

DA

EE

ED

AG
AS

LC
L, L'
LL

EA

BB

AF'

K'
A

Frame sizes 180 M/L and 225 S/M


have frame feet with 2 drilled
holes at NDE.

BA'

AA
AD'

AA
AB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00012

BE

GC
AH

GA

AG

AQ

AC

EC

EB

AS
LM,
LM'

FA

EE

DA

ED

AF
AD

LC

L, L'
LL

DC
EA
The motors are supplied with two fitted eyebolts conforming to IM B5,
whereby one can be repositioned to conform to IM V1 or IM V3. It is important
to note that stress must not be applied perpendicular to the ring plane.

DB
HH

For motor
Frame Type
size
180 M 1LG6 183
180 L
200 L

1LG6 186
1LG6 206
1LG6 207

225 S
225 M

1LG6 220
1LG6 223
1LG6 228

250 M

1LG6 253
1LG6 258

*
1)

Number
of poles
2
4
4, 6, 8
2, 6
2, 6
4, 8
4, 8
2
4, 6, 8
2
4, 6
2
4
6, 8
2
4, 6

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AG

AH

AQ

AS

B*

BA

BA' BB

BC BE

CA* H

HA

279

65

339 363 262 262 220 220 152 452 340

71 241

70 111 328 36

279
318
318

65
70
70

339 363 262 262 220 220 152 452 340


378 402 300 300 247 247 260 512 340
378 402 300 300 247 247 260 512 340

71 279
96 305
96 305

70 111 328 36
80 80 355 63
80 80 355 63

356
356

80
80

436 442 325 325 272 272 260 556 425


436 442 325 325 272 272 260 556 425

96 286
96 311

85 110 361 47
85 110 361 47

54 121 253
202
54 121 215
85 133 177
85 133 234
177
85 149 218
85 149 253

356

80

436 442 325 325 272 272 260 556 425

96 311

85 110 361 47

85 149 303 225 34

406 100 490 495 392 392 308 308 300 620 470 118 349 100 100 409 69

110 168 235 250 40


305
235
110 168 305 250 40

406 100 490 495 392 392 308 308 300 620 470 118 349 100 100 409 69

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

4/142

AF'

Siemens D 81.1 2007

180 20
180 20
200 25
200 25
225 34
225 34

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG6, frame sizes 180 M to 250 M
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00013

EC
BC

GC

DB
B
BA

CA

EE
EA

HA

AQ

AC

GA

AF
AD

BE
EB

LM,
LM
FA

ED

AG
AS

DA

LL

LC
L, L'

K'

DC

AF'
A

AA

BA'

AA
AD'

BB
AB

For motor
Frame
Type
size
180 M
1LG6 183
180 L
200 L

1LG6 186
1LG6 206
1LG6 207

225 S
225 M

1LG6 220
1LG6 223
1LG6 228

250 M

1LG6 253
1LG6 258

Number
of poles
2
4
4, 6, 8
2, 6
2, 6
4, 8
4, 8
2
4, 6, 8
2
4, 6
2
4
6, 8
2
4, 6

Dimension designation acc. to IEC


HH K
K'
L
LC
LL
157 15

19

157 15
196 19
196 19

19
25
25

196 19
196 19

25
25

196 19

25

237 24

30

237 24

30

720
669
720
720
777
720
789
819
849
869
899
887
957
887
957

835
784
835
835
892
835
903
933
963
983
1013
1002
1102
1032
1102

132
132
192
192
192
192
192
236
236

LM
810
759
810
810
867
810
889
919
949
969
999
987
1057
987
1057

DE shaft extension
D
DB E
EB

ED F

GA

NDE shaft extension


DA DC EA EC

EE

FA

GC

48

M16 110

100

14

51.5 48

M16 110 100

14

51.5

48
55
55

M16 110
M20 110
M20 110

100
100
100

5
5
5

14
16
16

51.5 48
59
55
59
55

M16 110 100


M20 110 100
M20 110 100

5
5
5

14
16
16

51.5
59
59

60
55
60
55
60
60
65
65
60
65

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

125
100
125
100
125
125
125
125
125
125

10
5
10
5
10
10
10
10
10
10

18
16
18
16
18
18
18
18
18
18

64
59
64
59
64
64
69
69
64
69

M20
M16
M20
M16
M20
M20
M20
M20
M20
M20

100 5
100 5
100 5
100 5
100 5
100 5
125 10
125 10
100 5
125 10

16
14
16
14
16
16
18
18
16
18

59
51.5
59
51.5
59
59
64
64
59
64

140
110
140
110
140
140
140
140
140
140

55
48
55
48
55
55
60
60
55
60

110
110
110
110
110
110
140
140
110
140

Siemens D 81.1 2007

4/143

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG6, frame sizes 280 S to 315 L
Type of construction IM B3
G_D081_XX_00014

EC

AF
AD

GC

BC

DB
E

DC

CA

BA

HA

GA

AQ

AC

DA

BE

EB

LM,
LM'

FA

EE

ED

AG
AS

LC
L, L'
LL

EA

BB

AF'

K'

Frame sizes 280 S/M and 315 S/M/L


have frame feet with
2 drilled holes at NDE.

BA'

A
AA
AD'

AA
AB

Types of construction IM B5 and IM V1


For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00012

GC
AH

GA

AQ

AC

EC

AG

FA

BE
EB

AS
LM,
LM'

DA

EE

AF
AD

LC
L, L'
LL

ED

DC
EA
The motors are supplied with two fitted eyebolts conforming to IM B5,
whereby one can be repositioned to conform to IM V1 or IM V3. It is important
to note that stress must not be applied perpendicular to the ring plane.

DB
HH

For motor
Frame Type
size
280 S
1LG6 280
280 M

1LG6 283
1LG6 288

315 S
315 M

2)

315 L2)

*
1)

1LG6 310
1LG6 310
1LG6 313
1LG6 313
1LG6 313
1LG6 316
1LG6 316
1LG6 316
1LG6 317
1LG6 317
1LG6 317
1LG6 318
1LG6 318
1LG6 318

Number
of poles
2
4, 6, 8
2
4
6, 8
2
4, 6
2
4, 6, 8
8
2
4, 6
2
4, 6
8
2
4, 6
8
2
4
6, 8

Dimension designation acc. to IEC


A
AA AB AC1) AD AD' AF

AG

AH

AQ

AS

B*

BA

BA' BB

BC BE

CA* H

HA

457 100 540 555 432 432 348 348 300 672 525 118 368 100 151 479 62

110 190 267 280 40

457 100 540 555 432 432 348 348 300 672 525 118 419 100 151 479 62

110 190 326 280 40

457 100 540 555 432 432 348 348 300 672 525 118 419 100 151 479 62

216
110 190 326 280 40

508 120 610 610 500 500 400 400 380 780 590 154 406 125 176 527 69

110 216 315 315 50

508 120 610 610 500 500 400 400 380 780 590 154 457 125 176 527 69
508 120 610 610 500 500 400 400 380 780 590 154 457 125 176 578 69

110 216 264 315 50


110 216 424 315 50

508 120 610 610 500 500 400 400 380 780 590 154 508 125 176 578 69

110 216 373 315 50

508 120 610 610 500 500 400 400 380 780 590 154 508 155 206 648 69

110 216 513 315 50

578
508 120 610 610 651 651 524 524 470 780 590 165 508 155 206 648 69

135 216 513 315 50

500 500 400 400 380

This dimension is assigned in DIN EN 50347 to the frame size listed.


Measured across the bolt heads.

4/144

AF'

Siemens D 81.1 2007

2)

110

With order codes for connection box positions (K09, K10, K11) only fitted
feet with 3 drilled holes with dimension B (406, 457 and 508 mm).
BB will then be 666 mm.

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings
Cast-iron series 1LG6, frame sizes 280 S to 315 L
Type of construction IM B35
For flange dimensions, see Page 4/146 (Z = the number of retaining holes)
G_D081_XX_00013

EC
BC

GC

DB
B
BA

CA

EE
EA

HA

AQ

AC

GA

AF
AD

BE
EB

LM,
LM
FA

ED

AG
AS

DA

LL

LC
L, L'

K'

DC

AF'
A

AA

BA'

AA
AD'

BB
AB

For motor
Frame
Type
size
280 S
1LG6 280
280 M

1LG6 283
1LG6 288

315 S
315 M
315 L

1)

1LG6 310
1LG6 310
1LG6 313
1LG6 313
1LG6 313
1LG6 316
1LG6 316
1LG6 316
1LG6 317
1LG6 317
1LG6 317
1LG6 318
1LG6 318
1LG6 318

Number
of poles
2
4, 6, 8
2
4
6, 8
2
4, 6
2
4, 6, 8
8
2
4, 6
2
4, 6
8
2
4, 6
8
2
4
6, 8

Dimension designation acc. to IEC


HH K
K'
L
LC
LL LM
252 24

30

252 24

30

252 24

30

285 28

35

285 28
285 28

35
35

285 28

35

285 28

35

285 28

35

DE shaft extension
D
DB
E
EB

960 1105 236 1070 65


75
1070 1215 236 1180 65
75
960 1105
1070 75
1070 1215 236 1180 65
75
1072 1217 307 1182 65
1102 1247
1212 80
1102 1247 307 1212 80
1232 1377 307 1342 65
1262 1407
1372 80
1232 1377 307 1342 65
1262 1407
1372 80
80
1372 1517 307 1482 65
1402 1547
1512 80
1262 1407
1372 80
1372 1517 330 1482 65
1402 1547
1512 801)
307
80

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

140
140
140
140
140
140
140
140
170
170
140
170
140
170
170
140
170
170
140
170
170

125
125
125
125
125
125
125
125
140
140
125
140
125
140
140
125
140
140
125
140
140

ED

GA

NDE shaft extension


DA DC EA EC

EE

FA

GC

10
10
10
10
10
10
10
10
25
25
10
25
10
25
25
10
25
25
10
25
25

18
20
18
20
20
18
20
18
22
22
18
22
18
22
22
18
22
22
18
22
22

69
79.5
69
79.5
79.5
69
79.5
69
85
85
69
85
69
85
85
69
85
85
69
85
85

60
65
60
65
65
60
65
60
70
70
60
70
60
70
70
60
70
70
60
70
70

10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10

18
18
18
18
18
18
18
18
20
20
18
20
18
20
20
18
20
20
18
20
20

64
69
64
69
69
64
69
64
74.5
74.5
64
74.5
64
74.5
74.5
64
74.5
74.5
64
74.5
74.5

M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20
M20

140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140
140

125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125

Diameters up to 90 mm are possible.

Siemens D 81.1 2007

4/145

Siemens AG 2007

IEC Squirrel-Cage Motors


Explosion-proof motors
Dimensions

Dimensional drawings

Frame size

Type of construction

56 M

63 M

71 M

80 M

90 S, 90 L

100 L

112 M

132 S, 132 M

160 M, 160 L

180 M, 180 L
200 L
225 S, 225 M
2-pole
4-pole to 8-pole
250 M
280 S, 280 M
315 S, 315 M,
315 L
2-pole
4-pole to 8-pole
315
2-pole
4-pole to 8-pole
355
2-pole
4-pole to 8-pole
400
2-pole
4-pole to 8-pole
450
2-pole
4-pole to 8-pole

4/146

In DIN EN 50347, the frame


sizes are allocated flange FF
with through holes and flange
FT with tapped holes.
The designation of flange A
and C according to
DIN 42948 (invalid since
09/2003) are also listed for
information purposes. See the
table below.
(Z = the number of retaining
holes)

G_D081_XX_00027

G_D081_XX_00026

Flange dimensions

IM B5, IM B35, IM V1, IM V3


IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM B35, IM V1, IM V3
IM B14, IM B34, IM V18, IM V19
IM B14, IM B34, IM V18, IM V19
IM B5, IM V1, IM V3
IM B5

Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Standard flange
Special flange
Flange
Flange

Flange with
through holes (FF/A)
Tapped holes (FT/C)
According to
Acc. to
DIN EN 50347
DIN 42948
FF 100
A 120
FT 65
C 80
FT 85
C 105
FF 115
A 140
FT 75
C 90
FT 100
C 120
FF 130
A 160
FT 85
C 105
FT 115
C 140
FF 165
A 200
FT 100
C 120
FT 130
C 160
FF 165
A 200
FT 115
C 140
FT 130
C 160
FF 215
A 250
FT 130
C 160
FT 165
C 200
FF 215
A 250
FT 130
C 160
FT 165
C 200
FF 265
A 300
FT 165
C 200
FT 215
C 250
FF 300
A 350
FT 215
C 250
FT 265
C 300
FF 300
A 350
FF 350
A 400

IM B5, IM V1, IM V3

Flange

FF 400

A 450

16

IM B5, IM V1, IM V3
IM B5, IM V1, IM V3

Flange
Flange

FF 500
FF 500

A 550
A 550

18
18

IM B5, IM V1, IM V3

Flange

FF 600

A 660

22

140 600
170

IM B35, IM V1

Flange

25

140
170

740 680 800 22

IM B35, IM V1

Flange

25

140
170

840 780 900 22

IM B35, IM V1

Flange

28

170
210

940 880 1000 22

IM B35, IM V1

Flange

30

170 1080 1000 1150 26


210

Siemens D 81.1 2007

Flange type

Dimension designation acc. to IEC

LA

LE

10

10

11

11

12

13

13
15

20
20
20
23
23
23
30
30
30
40
40
40
50
50
50
60
60
60
60
60
60
80
80
80
110
110
110
110
110

100
65
85
115
75
100
130
85
115
165
100
130
165
115
130
215
130
165
215
130
165
265
165
215
300
215
265
300
350

110 400
140
140 500
140 500

350 450 18.5 5

450 550 18.5 5


450 550 18.5 5

8
8

550 660 24

80
50
70
95
60
80
110
70
95
130
80
110
130
95
110
180
110
130
180
110
130
230
130
180
250
180
230
250
300

P
120
80
105
140
90
120
160
105
140
200
120
160
200
140
160
250
160
200
250
160
200
300
200
250
350
250
300
350
400

7
M5
M6
10
M5
M6
10
M6
M8
12
M6
M8
12
M8
M8
14.5
M8
M10
14.5
M8
M10
14.5
M10
M12
18.5
M12
M12
18.5
18.5

3
2.5
2.5
3
2.5
3
3.5
2.5
3
3.5
3
3.5
3.5
3
3.5
4
3.5
3.5
4
3.5
3.5
4
3.5
4
5
4
4
5
5

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Vous aimerez peut-être aussi