Académique Documents
Professionnel Documents
Culture Documents
AS CONEXES E A PROGRAMAO DA PCBS-CAT E PCS-CAT SO IDNTICAS, A NICA DIFERENA ENTRE AS DUAS QUE A PCBS-CAT POSSUI EM SEU TECLADO A INDICAO DE COMO CHAMAR VRIOS BLOCOS.
A INSTALAO E MANUTENO DESTE EQUIPAMENTO REQUER CONHECIMENTOS TCNICOS. CONFIE ESTES SERVIOS A UM PROFISSIONAL CAPACITADO.
- NDICE1 - DESCRIO GERAL 2 - CARACTERSTICAS E ESPECIFICAES TCNICAS 3 - INSTRUO DE INSTALAO 3.1 - COMO ABRIR A PLACA 3.2 - IDENTIFICANDO OS PONTOS DE CONEXO E CHAVE DE RESET 3.3 - COMO LIGAR A FONTE PLACA PCBS-CAT, PCS-CAT OU PIS-CAT 3.4 - COMO LIGAR A PLACA PCBS-CAT, PCS-CAT OU PIS-CAT CENTRAL 3.5 - COMO LIGAR A FECHADURA PLACA PCBS-CAT, PCS-CAT OU PIS-CAT 3.6 - COMO AJUSTAR O VOLUME DE UDIO DA PLACA DE RUA 3.7 - COMO ACOPLAR UMA BOTOEIRA PLACA 3.8 - AJUSTANDO A TENSO DE REDE ELTRICA 3.9 - LEDS DE ILUMINAO NOTURNA 4 - INSTRUES DE PROGRAMAO 4.1 - PR PROGRAMAO DE FBRICA DA PLACA 4.2 - COMO PROGRAMAR A PLACA 4.3 - PROGRAMANDO A SENHA DA PLACA 4.4 - PROGRAMANDO O NMERO DO RAMAL DE PORTARIA 4.5 - PROGRAMANDO SENHAS PARA ABERTURA DA FECHADURA 4.6 - DESPROGRAMANDO UMA SENHA ESPECFICA PARA ABERTURA DE FECHADURA 4.7 - DESPROGRAMANDO TODAS AS SENHAS PARA ABERTURA DE FECHADURA 4.8 - UTILIZANDO UMA NICA PLACA PCBS-CAT EM DUAS CENTRAIS ACOPLADAS 4.9 - RETORNANDO PR PROGRAMAO DE FBRICA 5 - INSTRUES DE OPERAO 5.1 - PLACA CHAMANDO APARTAMENTO 5.2 - PLACA CHAMANDO PORTARIA 5.3 - RAMAL CHAMANDO A PLACA 5.4 - ACIONANDO A FECHADURA ATRAVS DO TELEFONE 5.5 - ACIONANDO A FECHADURA ATRAVS DE SENHA NAS PLACAS PCBS-CAT OU PCS-CAT 6 - GUIA DE DEFEITOS
01 01 01 01 02 03 03 04 04 05 05 05 05 06 06 06 07 07 07 07 08 09 09 09 09 09 09 09 10
1 - DESCRIO GERAL
Projetadas para facilitar o controle de acesso em residncias e condomnios as placas PCBS-CAT, PCS-CAT e PIS-CAT (acessrios das centrais CAT e RIVIERA) permitem a comunicao com qualquer telefone ligado central e o acionamento de at duas fechaduras eletromagnticas.
Resistncia mxima dos fios de conexo 120 Ohms com o ramal Fusvel de proteo Proteo eltrica Proteo de programao DIMENSES
CDIGO PCBS-CAT PCS-CAT PIS-CAT FONTE PROFUN. LARGURA ALTURA PESO (mm) (mm) (mm) (g)
0,5 A Proteo contra transientes na entrada dos fios da linha telefnica. Memria EEPROM
Profun.
Largura
65 65 65 65
3
9I
Fig. 1
-1PLACA PCBS-CAT, PCS-CAT E PIS-CAT
Altura
Altura
4D 7G
6F
8H
PORTARIA
CHAMAR APARTAMENTO:
1A 4D 7G
2B
5E
3C
3
9I
6F
8H
0
Retire os parafuros
PORTARIA
CHAMAR APARTAMENTO:
Fig. 2
Fig. 3
Fig. 4
CHAVE DE RESET
CONEXO DOS FIOS PARA LIGAR A FECHADURA 1 CONEXO DO FIO PARA LIGAR A BOTOEIRA "R" CONEXO DOS FIOS PARA LIGAR O RAMAL
FONTE
RAMAL
FECH. 1 FECH. 2
FONTE
RAMAL
FECH. 1 FECH. 2
CENTRAL RIVIERA
L1
L2
L3
20
20
Fig. 7
CENTRAL CAT
20 21 22 23 24
RAMAL
21 22 23 24
FONTE
FECH. 1 FECH. 2
Fig. 8
-3-
FONTE
RAMAL
FECH. 1 FECH. 2
FECHADURA 2 (OPCIONAL)
Fig. 9
AJUSTE DO VOLUME
P1
J1
FONTE
RAMAL
FECH. 1 FECH. 2
Fig. 10
-4PLACA PCBS-CAT, PCS-CAT E PIS-CAT
FONTE
RAMAL
FECH. 1 FECH. 2
BOTOEIRA
Fig. 11
Fig. 12
4 - INSTRUES DE PROGRAMAO
A programao das placas PCBS-CAT, PCS-CAT e PIS-CAT bem simples, leia atentamente todos os itens abaixo antes de iniciar a programao.
-5PLACA PCBS-CAT, PCS-CAT E PIS-CAT
220
IMPORTANTE: A PLACA S SAI DO MODO DE PROGRAMAO APS COLOCAR O TELEFONE NO GANCHO. 4 PASSO: Discar o comando e aguardar o sinal de programao aceita ou no. 2 beeps curtos 1 beep longo A programao foi aceita A programao foi recusada
4 PASSO: Testando o funcionamento da PCBS-CAT; Toda a vez que se chamar um apartamento de um bloco superior ao que foi configurado na placa, ela automaticamente acessa a linha externa da central, isto , se voc discar na placa: + 1 + 1 0 - A placa chama o apartamento 10 do bloco 1 (central 1) + 6 + 1 0 - A placa chama o apartamento 10 do bloco 6 (central 2)
6 - GUIA DE DEFEITOS
PROBLEMA
Ao pressionar o teclado da placa no escuto nenhum sinal sonoro. Placa no chama. Volume da placa de rua est baixo. No aciona a fechadura.
SOLUO
1 - Verificar a conexo da fonte conforme manual. 2 - Verificar a tenso da fonte 110 / 220V. 1 - Verificar a conexo da placa com o ramal da central. 1 - Ajuste o volume atravs do trimpot (P1) localizado atrs da placa. 1 - Verificar as conexes da fechadura com a placa (conforme manual). 2 - Verificar se a fechadura compatvel com a placa (tem 2). 1 - Verificar o nmero de ramal em que est conectada a placa. 2 - Verificar a conexo entre a placa e a central. 1 - Pressionar a tecla RESET localizada atrs da placa conforme manual (pgina 2), para voltar a programao de fbrica.
-10-
AV. THEVEAR, 92 - BAIRRO QUINTA DA BOA VISTA - ITAQUAQUECETUBA - SO PAULO - BRASIL CEP 08597-660 - CX. POSTAL 1004 - FONE PABX (11) 4646-8222 - FAX (11) 4645-0435 www.thevear.com.br E-mail:thevear@thevear.com.br C.N.P 62.034.608/0001-94 .J. INDSTRIA BRASILEIRA
CD.: 29120028 - V.01