Vous êtes sur la page 1sur 1

Activity ID

AAC1620 AAC1624 AAC1622 AAC1625

Activity Description (RA000622BW)


Access to Reaches 1-4 Trackway for Systems MS#2 Access to Reaches 11-14 Track for Systems MS#3 Access to Reaches 5-10 Trackway for Systems MS#4 Access to Reaches 15-17 Trackway For Sys MS#5

SEGM FFGA TYPE Orig Dur


0 0 0 0

Early Start

Early Finish
01NOV02* 01NOV02* 01MAY03* 01AUG03*

2002 2003 2004 N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S CT O


Access to Reaches 1-4 Trackway for Systems MS#2 Access to Reaches 11-14 Track for Systems MS#3 Access to Reaches 5-10 Trackway for Systems MS#4 Access to Reaches 15-17 Trackway For Sys MS#5

CMGC ROSE QTR & UPPER INTERSTATE

LS10C EXPO DESIGN/BUILD


VSC0061 VSC0207

(RA010500BW)
0 0 01JUL03* 15SEP03
Delta/Vanport to Expo Final Complete (MS#2) Bridge Structure Subst Complete (MS#3)

Delta/Vanport to Expo Final Complete (MS#2) Bridge Structure Subst Complete (MS#3)

RUBY JUNCTION MODS (CMGC)


RJC0033 RJC0050 RJC0067 RJC0059 RJC0040 RJC0028 RJC0026

(RA010692BW)
0 0 0 01MAR02* 0 0 0 0 03JUN02 15AUG02 15AUG02 15NOV02 13AUG01 31OCT01
MS#3 Area 2-Mods to Existing Ops Bldg Ph 2 Compl MS#6 Area 4 - Ruby South MOW Occupancy MS#7 Area 4-Ruby South Building Complete MS#4 Area 2-Mods to Existing Ops Bldg Ph 3 Compl MS#5 Area 3 - Yard and OCS Complete MS#1 Area 1 - Existing Body Shop Complete

MS#2 Area 2-Mods to Existing Ops Bldg Ph 1 Compl MS#3 Area 2-Mods to Existing Ops Bldg Ph 2 Compl MS#6 Area 4 - Ruby South MOW Occupancy MS#7 Area 4-Ruby South Building Complete MS#4 Area 2-Mods to Existing Ops Bldg Ph 3 Compl MS#5 Area 3 - Yard and OCS Complete MS#1 Area 1 - Existing Body Shop Complete

CENTRAL CONTROL SOFTWARE (10S)


CCM0145 CCM0147 CCC0205 Central Control Hardware/Software Design Period Rail Control Center Available Ship/Install/Test Central Control Software 313* 12AUG02 31OCT03
Central Control Hardware/Software Design Period Rail Control Center Available

0 03NOV03 171* 03NOV03 02JUL04


Ship/Install/Test Central Control Software

LRVs (Dsg, Mfr, Test)


LRM0017 LRM0019 LRM0029 LRM0021 LRM0020

(RA000562BW)
766* 16OCT00A 0 29AUG02* 0 29NOV02 0 126 17OCT03 16OCT03 14APR04
Final Acceptance, Field Support, Misc. LRVs

Manufacture / Commissioning - LRV First Delivery to Site - LRV First LRV Commissioned / Delivered to TM Last LRV Delivered to Tri-Met Final Acceptance, Field Support, Misc. LRVs

16OCT03
First Delivery to Site - LRV

Manufacture / Commissioning - LRV

First LRV Commissioned / Delivered to TM Last LRV Delivered to Tri-Met

SYSTEMS TES/OCS/Subs (DFI, 2-Step) (RA010672BW)


SYM0016 SYM0019 SYM0020 SYI0016 SYI0035 SYI0017 SYI0025 SYI0055 SYI0045 SYI0065 SYI0085 SYI0075 SYI0095 SYT0119 SYI0046 SYT0120 Contract NTP - 10F TES/OCS/Street Lights Systems / Final Design Interface (10F) Systems Engineering/ Furnish/ 1st Delivery (10F) Mobilize for TES Construction (10F) Install TES/OCS/Sub - Killingsworth to Buffalo Mobilize Contractor -SB to Expo (10F) Install TES/OCS/Sub - RQ to Graham Sub Install TES/OCS - Overlook to Jarrett Install TES/OCS/Subst - Knott to Failing Install TES/OCS/Subst - Buffalo to Denver Install TES/OCS/Subst - Delta/Vanport to Expo Install TES/OCS/Subst - Fenwick to Delta/Vanport Install TES/OCS Rose Qtr to Interstate Testing of Local TPSS rooms and Equipment Systems TES Installation Complete Systemwide TES Integrated Testing 0 30 08NOV01 243 21DEC01 07NOV01 20DEC01 04DEC02
Contract NTP - 10F TES/OCS/Street Lights Systems / Final Design Interface (10F) Systems Engineering/ Furnish/ 1st Delivery (10F) Mobilize for TES Construction (10F)

0 04NOV02 142* 04NOV02 23MAY03 04DEC02 31MAR03 15JUL03 29AUG03 30OCT03 23DEC03 27FEB04 31MAR04 31MAR04 31MAR04 01APR04 31MAY04

Install TES/OCS/Sub - Killingsworth to Buffalo Mobilize Contractor -SB to Expo (10F) Install TES/OCS/Sub - RQ to Graham Sub Install TES/OCS - Overlook to Jarrett Install TES/OCS/Subst - Knott to Failing Install TES/OCS/Subst - Buffalo to Denver Install TES/OCS/Subst - Delta/Vanport to Expo Install TES/OCS/Subst - Fenwick to Delta/Vanport Install TES/OCS Rose Qtr to Interstate Testing of Local TPSS rooms and Equipment Systems TES Installation Complete Systemwide TES Integrated Testing

20 06NOV02 101* 06NOV02

51* 02MAY03 84* 02MAY03 63 04AUG03 59* 01OCT03* 63* 01DEC03* 23* 01MAR04* 23* 01MAR04 0 42*

SYSTEMS SIG/COMM/FARE (DFI, 2 step) (RA010673BW)


SCM0116 SCM0119 SCM0120 SCI0155 SCI0116 SCI0117 SCI0125 SCI0110 SCI0175 SCI0130 SCI0135 SCI0150 SCI0165 SCI0140 SCI0145 SCI0185 SCI0111 SCI0121 SCT0220 SCI0120 Contract NTP - 10G Sig/Comm/TVM Systems / Final Design Interface (10G) Systems Engineering/ Furnish/ 1st Delivery (10G) Install Central Control Hardware at Ruby Junct Mobilize for Sig/Comm Construction (10G) Mobilize Contractor -SB to Expo (10G) Install Signals - RQ to Albina/Mississippi Inst Communications - RQ to Albina/Mississippi Install Signals/Comm Existing EW MAX to RQ Inst Communications-Albina/Mississippi to Kenton Install Signals - Albina/Mississippi to Kenton Install Communications-DeltaPark to Expo Install Signals - Delta/Vanport to Expo Inst Communications-Kenton to DeltaPark/Vanport Install Signals - Kenton to Delta Park/Vanport Test Comm & Central Control Equipment at Ruby Systems Signals/Communications Complete MS# 16 Complete Sonet System Testing Signals & Communications Integrated Testing Install Fare Collection Equipment 0 51* 243 10OCT01 21DEC01 09OCT01 20DEC01 04DEC02 29OCT03
Mobilize for Sig/Comm Construction (10G) Systems / Final Design Interface (10G) Systems Engineering/ Furnish/ 1st Delivery (10G) Install Central Control Hardware at Ruby Junct

306 19AUG02 0 60 107* 107* 107* 213* 213* 63* 63* 53* 53* 2 0 0 107* 02FEB04 05DEC02 05DEC02 01APR03 01APR03 01APR03 01APR03 01APR03 02JUL03 02JUL03 16SEP03 16SEP03 30OCT03

28FEB03 29AUG03 29AUG03 29AUG03 30JAN04 30JAN04 30SEP03 30SEP03 28NOV03 28NOV03 31OCT03 30JAN04 30JAN04* 30JUN04 31MAY04

Mobilize Contractor -SB to Expo (10G) Install Signals - RQ to Albina/Mississippi Inst Communications - RQ to Albina/Mississippi Install Signals/Comm Existing EW MAX to RQ Inst Communications-Albina/Mississippi to Kenton Install Signals - Albina/Mississippi to Kenton Install Communications-DeltaPark to Expo Install Signals - Delta/Vanport to Expo Inst Communications-Kenton to DeltaPark/Vanport Install Signals - Kenton to Delta Park/Vanport Test Comm & Central Control Equipment at Ruby Systems Signals/Communications Complete MS# 16 Complete Sonet System Testing Signals & Communications Integrated Testing Install Fare Collection Equipment

42* 01APR04*

START-UP
SUT0950 SIMULATED REVENUE OPERATIONS 46 01JUL04 03SEP04
SIMULATED REVENUE OPERATIONS

REVENUE SERVICE
STT0900 IMAX Ready for Revenue Service 0 03SEP04
IMAX Ready for Revenue Service

N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S CT O 2002 2003 2004


Early Bar Progress Bar Critical Activity Systems Design Mgr: Thomas Heilig MAST Sheet 1 of 1 Interstate MAX Light Rail Project Systems Design & Construction Activities Scheduled as of April 25, 2001

Primavera Systems, Inc.