Académique Documents
Professionnel Documents
Culture Documents
IMC 7318AEDG
Copyright (C) Siemens Mobile Communications S.p.A. V.le Piero e Alberto Pirelli, 10 I-20126 Milano
Issued by Technical Assistance Department S.S. 11 Padana Superiore, km 158 I-20060 Cassina de Pecchi MI Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. Authors: Authorized: E. Ciferri M. Diani
1 2
SRAL XD ALLOWED CONFIGURATIONS.................................................................. 5 LICENSE UPGRADING PROCEDURE ....................................................................... 6 2.1 2.2 REQUIREMENTS................................................................................................. 6 PROCEDURE....................................................................................................... 7
ANNEX A ................................................................................................................... 14
REVISIONS Issue
1
Date
May 2004
Author(s)
E. Ciferri
Chapter(s)
ALL
Cause
NEW
Change
Acronyms
MW Microwave Networks TAC Technical Assistance Centre TSO Technical Support Organization LC Siemens Local Company
Parameters Capacity
Meaning Maximum capacity software selectable (up to 16E1) Maximum modulation levels (up to HD 16TCM) System type covered (1 or 2 Base Band working)
Modulation
ND
ND/HD
System type
1+0
1+0/ALL
Following table shows the allowed configurations related to the license type of IDU unit: License type 4E1,1+0, ND 8E1,1+0,ND 16E1,1+0,ND 8E1,1+0,HD 16E1,1+0,HD 4E1,1+1, ND 8E1,1+1,ND 16E1,1+1,ND 8E1,1+1,HD 16E1,1+1,HD Allowed configurations capacity 4X2, Not protected 1+0, ND modulation capacity up to 8X2,Not protected 1+0, ND modulation capacity up to 16X2,Not protected 1+0, ND modulation capacity up to 8x2, Not protected 1+0, ND modulation capacity 8x2, Not protected 1+0, HD modulation capacity up to 16x2, Not protected 1+0, ND modulation capacity 8x2/16x2, Not protected 1+0, HD modulation capacity 4X2, All system types, ND modulation capacity up to 8X2, All system types, ND modulation capacity up to 16X2, All system types, ND modulation capacity up to 8X2, All system types, ND modulation capacity 8X2, All system types, HD modulation capacity up to 16X2, All system types, ND modulation capacity 8X2/16x2, All system types, HD modulation
(1)
The default value is the minimum license for each parameter. - 5/15 Mod. IMC 7318AEDG Issue 01
2.2
PROCEDURE
This procedure is applicable to Single Board and Plug-in IDU version. Each parameter described must be upgraded separately from the other ones. Thus the following procedure must be repeated if more than one parameter needs to upgrade. Note: The license downgrading is not foreseen.
1. Install LicenseManager tool running lm*_***SETUP.exe (where *_*** corresponds to the version of LicenseManager tool, for example: lm3_4b2SETUP.exe) on CD of Upgrading License Kit:
2.Flag SRAL XD
At the end of installation, the lm_SRAL XD shortcut is available on desktop or in Start Menu (in SIEMENS License Manager folder).
6.Have a connection with LCT or NetViewer to IDU SRAL XD, open Feature Control window and read License-Mask and Challenge-Number fields.
Important Note: Make sure that IDU is in stable condition: do not switch of the IDU, do not perform software reset or controller switch bank up to the end of license upgrading procedure. 7. Connect Smart Key (contained in Upgrading License Kit) to appropriate PC port. 8. Run LicenseManager tool (lm_SRAL XD shortcut). If a message below appears
the Smart Key is not properly equipped or a wrong type is used or the appropriate driver is not correctly installed. In this case run the skeyadd.exe present in the KeyP.zip folder contained in the CD-Rom. When the LicenseManager is on run, the window below appears:
9.Write current License Mask 10.Write current Challenge Number 11. Press Show License button to verify the existing license into the Smart Key 12.Flag feature you want to enable
(*) Note: Press Generate button only when you filled all boxes with the correct values. When License key is generated the total Credits of smart key will be decreasing according to the value of updated feature. Moreover every License-Key is strictly associated to the IDU that has the specified LicenseMask and Challenge-Number.
and DONT CLOSE the License Key Generation window (for more safety memorize the four License-Key fields in a text file). 16. Press Modify button on Feature Control window in order to enable License Mask writing:
17. Copy the first field of generated License-Key into the License Key #1 field:
Double Click
18. Repeat previous step for the other 3 fields of License-Key and Press Upgrade button on Feature Control Window:
19. Feature Control window automatically close. Open it again and verify that License Type has the new value:
3 ANNEX A
The list below shows the code of all license kit can be ordered. The kit changes about the wanted parameter to upgrade and number of fee the Smart Key has got.
CODE
625-018/11A100Q 625-018/11A200Q 625-018/11A300Q 625-018/11A010Q 625-018/11A001Q
SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs) SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs) SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs) SB KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs) SB KIT FOR EXP. FROM HP TO HD (2 NEs)
SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (10 NEs) SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (10 NEs) SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (10 NEs) SB KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs) SB KIT FOR EXP. FROM HP TO HD (10 NEs)
SB KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs) SB KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs) SB KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs) SB KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs) SB KIT FOR EXP. FROM HP TO HD (50 NEs)
IDU PLUG-IN FAMILY 625-018/10A100Q 625-018/10A200Q 625-018/10A300Q 625-018/10A010Q 625-018/10A001Q PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (1 NE) PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (1 NE) PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (1 NE) PI KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE) PI KIT FOR EXP. FROM HP TO HD (1 NE)
PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs) PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs) PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs) PI KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs) PI KIT FOR EXP. FROM HP TO HD (2 NEs)
PI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs) PI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs) PI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs) PI KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs) PI KIT FOR EXP. FROM HP TO HD (50 NEs)
MINIDU FAMILY 625-018/12A100Q 625-018/12A200Q 625-018/12A300Q 625-018/12A010Q 625-018/12A001Q MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (1 NE) MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (1 NE) MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (1 NE) MI KIT FOR EXP. FROM (1+0) TO (1+1) (1 NE) MI KIT FOR EXP. FROM HP TO HD (1 NE)
MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (2 NEs) MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (2 NEs) MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (2 NEs) MI KIT FOR EXP. FROM (1+0) TO (1+1) (2 NEs) MI KIT FOR EXP. FROM HP TO HD (2 NEs)
MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (10 NEs) MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (10 NEs) MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (10 NEs) MI KIT FOR EXP. FROM (1+0) TO (1+1) (10 NEs) MI KIT FOR EXP. FROM HP TO HD (10 NEs)
MI KIT FOR CAP. EXP. FROM 4E1 TO 8E1 (50 NEs) MI KIT FOR CAP. EXP. FROM 8E1 TO 16E1 (50 NEs) MI KIT FOR CAP. EXP. FROM 4E1 TO 16E1 (50 NEs) MI KIT FOR EXP. FROM (1+0) TO (1+1) (50 NEs) MI KIT FOR EXP. FROM HP TO HD (50 NEs)