RTN600 Installation Quality Standard Version 1.0

2009-03-03

HUAWEI Confidential

Page1, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Contents
Indoor Installation..................................................................................................4 Rack Installation....................................................................................................4 Equipment Installation...........................................................................................4 RTN600 Installation ..............................................................................................4 Power cable routing ..............................................................................................4 Power cable from APM .........................................................................................5 Power cable routing to cabinet from APM.............................................................5 DCDB termination .................................................................................................6 Power cable routing from DCDB to equipment .....................................................7 Indoor Grounding ..................................................................................................8 Rack Grounding ....................................................................................................8 RTN600 equipment grounding ..............................................................................9 Grounding connectors...........................................................................................9 IF Cable connection and routing ...........................................................................9 Cable connector issues.........................................................................................9 Routing through the rack.....................................................................................10 Routing on the ladder..........................................................................................10 E1 cable routing ..................................................................................................10 E1 trunk cable fixing and routing.........................................................................10 Optical cable routing ...........................................................................................11 Indoor Labeling ...................................................................................................11 DCDB Label ........................................................................................................11 RTN 600 IDU Label.............................................................................................12 DDF panel Label .................................................................................................12 Power cable Label ..............................................................................................12 IF Cable Label ....................................................................................................13 Signal Cable Label..............................................................................................13 Optical Cable Label.............................................................................................14 Outdoor Standards..............................................................................................14 Antenna Installation ............................................................................................14 Installation of antenna without offset issues........................................................15 Pole installation...................................................................................................17 Side bar installation.............................................................................................18 Brackets..............................................................................................................20 ODU installation ..................................................................................................20 Direct Mount 1+0,1+1 .........................................................................................20 Remote mount ....................................................................................................20 IF cable connection and routing ..........................................................................21 IF cable connection near antenna.......................................................................21 Water proof curve ...............................................................................................21 Loop near to antenna..........................................................................................22 Out door Grounding ............................................................................................22
2009-03-03 HUAWEI Confidential Page2, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

ODU Grounding ..................................................................................................22 IF cable Grounding .............................................................................................23 Waterproof at the groundings .............................................................................24 Outdoor Labels ...................................................................................................25 IF Cable Label ....................................................................................................25 Bundling and fixing the cables using Cable Ties.................................................25 Common issues in fixing Cable ties ....................................................................26 Appendix.............................................................................................................27 Installing the Grounding Clip...............................................................................28 IF connector Making procedure ..........................................................................29 Installing the ODU on the Antenna......................................................................30

2009-03-03

HUAWEI Confidential

Page3, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Code No 1 1.1

Descriptions
Indoor Installation
Rack Installation Rack Should be fixed vertically and fixed to the floor tightly. According to the floor type, you should use the proper bolts, anger bolts, nuts, spring washers, flat washers etc. No all bolts fixed Correct way:

Remark: Before start to install the equipment, We have to confirm whether the rack is installed properly or not.
1.2

1.2.1

Equipment Installation Equipment should be fixed accordance with the rack layout in TSSR and it should be horizontal. All the four bolts available in the installation accessories should be used. RTN600 Installation Have to consider the location marked in TSSR rack layout and check whether that location is available or not. Then install the equipment horizontally using all bolts as shown below

1.3

Power cable routing Power source for the equipment, for the reference here is taken as APM200. According to the TSSR Power should be tapped from the power source.
HUAWEI Confidential Page4, Total33

2009-03-03

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.3.1

Power cable from APM Power cable Should be taken from the APM from the primary (within 1-3 terminals) and within(10-11 terminals) Correct way of termination in Wrong Termination in APM APM power.

1.3.2

One is from the Primary(1-3) Power Tapped from 10th and 11th and other one is from the (from tertiary(10-11) common terminal Power cable routing to cabinet from APM Power from the APM should be routed to the cabinet using GI pipe. And this GI pipe should be laid out properly and neatly according to the standards. Wrong way of GI pipe Good way of GI pipe routing Routing

Remark:
Have to consider the following issues, when you route the power cable through GI pipe GI pipe should be fixed with the wall or floor very tightly

2009-03-03

HUAWEI Confidential

Page5, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Open area to get the power cable should be closed with rain proof GI pipe size should be according to the requirement. It should not be very big or very small and also not longer or shorter Layout of GI pipe should be very neat and accordance to the standards. At the outlet all the cables should be taken out using flexible PVC.

Grounding the GI pipe When you route the GI Pipe have to consider the Grounding of GI Pipe.

Method 1: The Grounding Horse clip should be tighten with the GI Pipe and It should be connected to nearest grounding bar Method 2: Drill the GI pipe and fix the grounding bolt and fix the other end to the Grounding Bar. Remark: If the Black horse (GI coated PVC pipe- Black Color) is used, the inner metal shield will be grounded using the same horse clip.
1.3.3

DCDB termination DCDB should be fixed as the two common working ground bus bars (0V common bus bar) are at bottom as shown in the below photo. When You terminate the Power source and outlet for equipments, have to consider the following issues. 1. Each power Source cable should be separately terminated and breakers should be separated for 1+1. 2. Power source cable should share the power to the other breakers using common bus bar. 3. And the cables for equipments should be taken from the other side. Example of correctly installed and terminated DCDB Remark: 1. Make sure -48V cables(Blue) are routed through the breakers

2009-03-03

HUAWEI Confidential

Page6, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2. Make sure that, there is no main breaker that is isolated from the other breaker. 3. Make sure only one equipment is terminated in one breaker 4. Make sure the effective 1+1 distribution.

1.3.4

Power cable routing from DCDB to equipment Pay attention the following: 1. DCDB termination should use the code end terminals of the power cables 2. If it is 1+1, both cables should be routed inside the rack (Should use the left side of the rack) from the DCDB and bound up neatly and tightly as shown below.

3. Dont cross the power cables with signal cables as well dont twist the
2009-03-03 HUAWEI Confidential Page7, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.4

1.4.1

cables when you route inside the rack Indoor Grounding All the equipments, rack should be grounded to the main grounding bar directly or by another grounding bar using proper grounding cables. Rack Grounding: 16 mm2 yellow green cable Equipments grounding: 5.3 mm2 yellow green cable All the grounding cables should be grounded using appropriate OT connectors and fixed properly using proper tools. Rack Grounding NEC 19 inch rack 1. Have to fix the grounding mesh in the left side 2. Grounding mesh should be grounded to the main grounding bar using 16 mm2 green yellow grounding cables

Ericson rack If it is the 19 inch rack without the grounding mesh (-Ericson rack) then, Rack should be grounded at the TOP point where all equipment groundings can be tapped

Remark: Appropriate OT connectors should be used to connect the grounding and fixed using relevant Crimping tools.
2009-03-03 HUAWEI Confidential Page8, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.4.2

RTN600 equipment grounding NEC 19 inch rack with mesh The dual-hole OT terminal of the protection grounding cable must be fixed on the left of the IDU as below. The other side of the grounding cable, we have to ground to the nearest ground mesh point by fixing the appropriate OT connector.

Ericson 19 inch rack without the mesh All the grounding cables should be tapped to the main grounding point where the rack is grounded to the grounding bar.

1.4.3

1.5

1.5.1

Grounding connectors 1. Grounding cables of RTN600 is available with the accessories. One end will be available as fixed with dual-hole OT terminal. 2. Make sure the cable length for routing to the nearest grounding point. 3. 6 mm2 OT connectors should be used for the other end termination. IF Cable connection and routing 1. IF cable for RTN 600 have IF Jumper and inch IF cable. 2. IF Jumper connected to the 5th or 7th IF board should use the left side outer routing of the rack. 3. IF Jumper connected to the 6th or 8th IF board should use the right side outer routing of the rack. Cable connector issues In the IF cable connector making have to consider the following steps
HUAWEI Confidential Page9, Total33

2009-03-03

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Clamp1 Clamp2 1. Check the connection is very tight. 2. Check the copper inner wire is long enough as mentioned. 3. Ensure the braided shield is fold back to cover clamp 1 tightly. 4. Redundant part of the shielding layer should be cut and removed off. Routing through the rack IF cable jumper should be routed like below using the outer of the rack. If the other side If the Board is in slot 5th and 7th

1.5.2

1.5.3

1.6

1.6.1

Routing on the ladder If the Jumper cable is more, the extra cable should be put in a loop and fixed properly on the ladder. Ensure that the Jumper and the IF cable connection is reliable and fix near to connector in accessible way. E1 cable routing E1 Cable should be routed through inside the right side rack. Fix the cable ties properly. E1 trunk cable fixing and routing

2009-03-03

HUAWEI Confidential

Page10, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.7

Optical cable routing 1. Up to the rack and inside the rack Optical cable should be routed using PVC flexible conduit.

2. Use the flexible shrink to route the optical fiber to the SL1 or SD1 card.

1.8 1.8.1

Indoor Labeling DCDB Label In DCDB, each breaker should be labeled using permanent markers in an ordered way. (Left to Right). Breaker Number Label

2009-03-03

HUAWEI Confidential

Page11, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.8.2

RTN 600 IDU Label In the IDU itself, We have to print IDU Name in the sticker paper and paste it in IDU as below. Rack1-RTN620-1 Information include 1. Rack Name 1. Type of the IDU 2. Location Number Remark: Pls paste this label on the Top of the RTN in the way of visible.

1.8.3

DDF panel Label If it is 75 Ohm I/O board each I/O board should be labeled using sticker label in the order of top to bottom. If 120 ohm block all blocks should be labeled at the top in the ordered way from left to right and top to bottom E.g. Rack1-1 Information Includes 1. Which rack DDF (Here Rack1) 2. Which order of the DDF ( Here number 1) Remark: If there are many I/O boards in the rack, it is required to put the label according to the above standard. Power cable Label The label for power cables is rectangular with round corners. Have to use the label with cable tie to tie up: Have to indicate the following information. 1. DC -48 V 2. To which Breaker it goes.

1.8.4

2009-03-03

HUAWEI Confidential

Page12, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

1.8.5

IF Cable Label IF Jumper cable should labeled using the Sticker label as below.

1.8.6

Signal Cable Label If it is the 75 Ohm each and every E1 should be separately labeled. The Label at the DDF side

To: Information 1. Connected link far end Site ID(GAM003) 2. Equipment ID (Here RTN1) 3. Slot Number (Here Number 4) 4. Board Name ( Here PH1) 5. E1 port at PH1 port (Here Number 1) 6. Whether TX or RX ( Here TX) From Information: 1. Rack Information (Here DDF1) 2. DDF Location Number (Here 3rd one) 3. E1 port number at I/O board (Here 4th E1) 4. Whether RX/TX( Here TX) Label at the I/O board near to RTN600 will be as

2009-03-03

HUAWEI Confidential

Page13, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

For 120 Ohm We have to Label on the Trunk Cable as below Near to RTN 600

1.8.7

Optical Cable Label Optical Fiber to MUX should be Labeled like To : Equipment name-Slot Number- Card Name- port number-TX/RX From: Equipment name-Slot Number- Card Name- port number-TX/RX E.g.: To : OSN2-17SPLT1-1-TX From : RTN1-5SD1-1-RX Near to MUX To : RTN1-5SD1-1-RX From : OSN2-17SPLT1-1-TX

2.0 2.1

Outdoor Standards
Antenna Installation Antenna location Refer the TSSR and find out the proper location of antenna. E.g. you can get the information of Antenna height, link azimuth, antenna diameter, hop length etc from this diagram. Note: Confirm the exact location before start the installation.

Check all the u bolts, brackets support collar, azimuth adjustment collar, elevation adjustment assembly are all installed properly according to the
2009-03-03 HUAWEI Confidential Page14, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

standard. Remark: Pls refer separate installation guide for very detail information about specific product antenna installation.

Elevation adjustment assembly should be fixed like below

2.1.1

Installation of antenna without offset issues When you install the antenna, have to consider the following issues for the easy maintenance purposes: 1. Antenna is easy accessible 2. ODUs and IF cables are accessible

2009-03-03

HUAWEI Confidential

Page15, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Access to the ODU for maintenance is very difficult

Accessing the ODU for maintenance is easy.

Remark: When you fix the antenna, You have to ensure whether the right offset or left offset of the antenna provides easy access to the antenna system.

Offset Right

Offset left

Remark: In both Cases, the azimuth alignment bolt is at bottom. E.g. ) 3 Meter RFS antenna offset arrangement is as below Offset left (Standard) - Insert drain plug in hole on the top Offset right - Rotate antenna 180 degrees of the reflector. - Rotate radome 180 degrees - Insert drain plug in hole on the top of the reflector. Offset Right Offset Left

2009-03-03

HUAWEI Confidential

Page16, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2.1.2

When you change these positions from left to right or right to left pls consider the followings 1. Alignment bolt is at the back side. 2. Antenna hanging U cut is upwards. Remark: Each and every type of antenna and changing of brackets and offsets are different. You have to refer the detail information of relevant antenna installation standards and accordance to that the standard procedures should be followed. Pole installation Installation of brackets for pole When you install the poles, make sure the followings. Brackets are suitable accordant to tower legs(L type or Star Type) The pole should be vertical and without any tilt Install the breakers according to the standards as shown below. Insert all thread bars, washers and ensure they are tight well.

The following figure show some wrong installation

2009-03-03

HUAWEI Confidential

Page17, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

If the thread bar is not long enough or the brackets are not suitable for the particular tower leg please confirm with relevant person. Pole should be vertical without any tilt

Remark: Ensure the fixing holes, to make sure the pole is vertical.
2.1.3

Side bar installation Side Bar should be fixed vertically and horizontally perpendicular to the antenna pad. Generally allowed deviation as follow.

Limits of strut position for attachment to tower member:

2009-03-03

HUAWEI Confidential

Page18, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Correct examples:

Wrong examples:

Remark1: if you couldnt find any location to fix the side bar accordance with the side bar. Pls confirm the solution with relevant acceptance body and start to install. Remark2: Each and every types of antenna require different types of sidebar installations and the tolerance of tilting angles are different to each other. It is highly expected you have to follow the relevant antennas side bar installation guide and have to follow the procedures according to that.

2009-03-03

HUAWEI Confidential

Page19, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2.1.4

Brackets Ensure all the brackets are appropriate one for the specific requirement. When you install Ensure all bolts, nuts and washers are used to fix the brackets. Side Bar brackets

2.2 2.2.1

ODU installation Direct Mount 1+0,1+1

Check the side of the brackets. Check whether all the check nuts are there. Check alignment bolts are back side and easy to access.

2.2.3

Remote mount

Check No damage bending in the soft waveguide Enter points are waterproofed according to the standard Check whether the remotely mounted ODUs are fixed in the easy way of accessible.
2009-03-03 HUAWEI Confidential Page20, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2.3

IF cable connection and routing Pls ensure the following in IF cable routing 1. The IF cable should be routed from top downwards and should be bound at the time of routing. 2. The specifications and cross-sectional area of the cable, and the route and position for the cabling should be decided beforehand. 3. The cable should be arranged neatly without any overlapping or crossover. 4. The IF cable should be curved for waterproof consideration under the ODU and before entering the IDU room. 5. The bending radius of the IF cable should be larger than 30 cm. 6. The IF cable should be bound by using the cable ties for outdoor use every one meter. 7. The cable ties for outdoor use should face the same direction. There should be a slack of 3 mm to 5 mm before cutting the cable ties.

If Cable Routing

2.3.1

2.3.2

IF cable connection near antenna IF connector should be fixed to the ODU firmly and water proofed according to the standard(Refer the appendix) Water proof curve Have to ensure there should be water proof curve at the entrance to the cabinet and near to the ODU.

2009-03-03

HUAWEI Confidential

Page21, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2.3.3

2.4

Loop near to antenna 1. 3-5 m Loop of IF cable should be neatly fixed near to the ODU and after the 1st grounding of the IF cable, to make sure the availability of IF cable for future alterations and alignment. 2. Ensure the loop bending diameter should not be less than 0.6 m Out door Grounding Out door grounding include ODU grounding and IF cable grounding. When you are grounding any cables, ensure one end of the cable is effectively connected the main grounding bar directly or other routes. Remark: All grounding cables should be down wards.

2.4.1

ODU Grounding

Remark: 1. Grounding cable should be fixed tightly at the ODU and it should be routed downwards. 2. Other end should be connected to nearest possible grounding point. 3. If Grounding point is not there nearly, first remove the anticorrosion paint and the oxidizing layer on where you want to fix the grounding. 5. The grounding cable should not be spiral. 6. After the connection, rustproof and waterproof the grounding points. If you are grounding to the Tower Ensure the paint at the grounding point ise removed and after fixation again repainted
2009-03-03 HUAWEI Confidential Page22, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

The grounding cable should be neatly routed and tied and fixed to the shortest possible place as below.

Practical scenarios of rounding issues:

2.4.2

IF cable Grounding IF cable should be grounded through out its routing. If the IF cable Length is greater than 60 m IF cable should be grounded in 4 points 1. Nearest possible from ODU: Before the loop: marked as 1 2. Before the bending : marked as 2 3. Mid place in the tower marked as 3 4. At the entry point : marked as 4

2009-03-03

HUAWEI Confidential

Page23, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

If the IF cable is less than 60m, then 3 grounding points are enough. 1. Near to the ODU 2. Before the Bending 3. Before the entry point

Remark: When you ground the IF cable pls consider the following issues 1. All grounding cables should be downwards. 2. Grounding clip is fully tightened with the outer mesh. 3. Water proof is made according to the standard way. Refer 3.1 for how to water proof.
2.4.3

Waterproof at the groundings IF cable connector at the ODU needs properly made waterproof.
HUAWEI Confidential Page24, Total33

2009-03-03

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

For the standard procedure of water proof, Refer the appendix. Check whether IF cable is water proofed properly according to the standard (Refer the procedure in appendix)

Check whether Cable ties at top and bottom of water proof

2.5 2.5.1

Outdoor Labels IF Cable Label

3.0

The labels for IF cables should be bound with the IF cables by using the cable ties for outdoor use. Bundling and fixing the cables using Cable Ties Cables must be tightly bundled. The bundled cables should be neatly arranged. For this We have to use three types of cable ties 1. Big ,thick and long Black color cable ties: for out door use a. IF cable fixing through out the tower. b. To protect the both ends of the water proof

2009-03-03

HUAWEI Confidential

Page25, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

2. White small cable ties: Indoor a. To fix the cables (Power cables, Grounding cables) with the rack holes. 3. Black long thin cable ties: Indoor a. Tight the cables on the ladder

Cable ties for indoor and outdoor:

3.1

Common issues in fixing Cable ties Bundling The bundling requirements are as follows: 1. Do not bind the power cable with other types of cables. 2. The cables should be bundled neatly. 3. Use cable ties of different specifications according to actual circumstances. 4. Do not connect two or more cable ties and use them as one to bundle cables in case the tightness is reduced. 5. After the cable ties are fixed, the extra part of the cable ties should be trimmed such that no burrs exist. 6. The spacing between the cable ties should be even and should be three or four times the diameter of the bundle. 7 When making turns for bundled cables, ensure that the bending radius is as large as possible so that the cable cores do not break.

2009-03-03

HUAWEI Confidential

Page26, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

IF routing Black UV protect tie-wrap should be used, and fixing IF cable by cross tightens. For the vertical and horizontal cable run, fixing less than 1m intervals by the tie-wrap. The IF cable must fix not loosened but not strong tightened and not any deformation to IF cable.

4.0 4.1

Appendix Waterproofing Outdoor Connectors Required material:

2009-03-03

HUAWEI Confidential

Page27, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Step 1: Clean the connector or the grounding clip. Step 2: Uncoil the waterproof insulation tape. Step 3: Stick one end of the tape to the IF cable 2 to 5 cm away from the connector or the grounding clip. The sticky side should face inwards. Step 4: Stretch the tape until it is 3/41/2 as wide as its original size. Stretch the tape in this manner when performing the following steps. Step 5: Wrap the cable spirally towards the connector or the grounding clip at a point that is 2 to 5 cm away from the connector or the grounding clip. Make sure that the overlapping area of the adjacent tape layers is 1/2 of the stretched width. Step 6: When the tape reaches a point that is 2 to 5 cm away from the connector or the grounding clip on the other side, reverse the wrapping direction so that the tape reaches the starting point. Step 7: When the tape reaches the starting point, reverse the wrapping direction so that the tape reaches the other ending point. That is, there are three layers of waterproof insulation tape. Step 8: After wrapping, squeeze the tape until it sticks to the cable. This ensures that there is no air between the layers of tape. Step 9: Similarly, wrap three layers of PVC tape over the waterproof insulation tape. During the wrapping, maintain the stretched length such that the width of the PVC tape is to 1/2 of the original size. Step 10: After waterproof processing, use the outdoor bundling strap to bind the PVC tape tightly at the positions 1 cm away from the wrapping edges at both ends, to prevent aging and falling off of the PVC tape.
Appearance of waterproofed outdoor connector

4.2

Installing the Grounding Clip

2009-03-03

HUAWEI Confidential

Page28, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Step1: Use an electric knife to strip the cable sheath with the openness being the clip size at the installation location of the grounding clip and expose the external conductor.

Step 2: Clip the cable by using the grounding clip and press the clip tightly. The angle between the grounding wire of the clip and the IF cable should not be larger than 15 degrees. When the IF cable is vertically routed, the grounding wire of the clip should be led downwards.

4.3

Step 3: Refer to the above section Waterproofing Outdoor Connectors to waterproof the grounding clips. IF connector Making procedure Step 1: Use an electric knife to strip back the 16 mm cable sheath. Stripping back the cable sheath and the insulating layer

Step2: Fit the lock nut and clamp 1 on the cable.


Fitting the lock nut and clamp 1

Step 3: Fit clamp 2.


1. Fold back the braided shield to cover clamp 1. 2. Tidy the braided shield and use clamp 2 to bind the braided shield. 3. Cut the redundant part of the shielding layer.

2009-03-03

HUAWEI Confidential

Page29, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Step 4: Use the electric knife to strip back the dielectric insulating layer in front of clamp 2.During the operation, the exposed cable wire should be 6 mm long. Stripping back the insulating layer

Step 5: Use a file to taper the edge of the core wire about 0.5 mm to make the top in an arc shape, and clean out the metal filings. Step 6: Fit the connector.

Step 7: Connect the connector and the lock nut. Use a wrench to tighten the connection. Use wrench 1 to rotate the lock nut and wrench 2 to position the body of the connector. The recommended torque is 152 Nm.
Fastening the connector

4.4

Installing the ODU on the Antenna Step1: Remove the protective caps from the feed boom of the antenna and from the ODU antenna port. Apply the appropriate quantity of lubricant on the gasket of the feed boom and the surface of the waveguide near the gasket.

2009-03-03

HUAWEI Confidential

Page30, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Step 2: Ensure that the V mark on the OTU points in the polarization direction of the antenna. If the antenna is vertically polarized, ensure that the V mark points upwards or downwards. If the antenna is horizontally polarized, ensure that the V mark points left or right. Place the ODU antenna port against the feed boom. Slowly fit the feed boom in such that the four ODU latches engage with the four antenna hooks.

Remark: When you install the ODU, the IF port of the ODU should face downwards.
4.4.1

Installing the Hybrid Coupler on the Antenna Step 1: Check the polarization direction of the antenna. Step2: If the antenna is vertically polarized, no need to change anything and go to step 3 or if the antenna is horizontally polarized do the following to change the polarization Install a horizontal polarizer. 1. Remove the protective cap from the antenna port on the coupler. 2. Remove the polarization component on the antenna port of the coupler. 3. Replace the polarization converter on the polarization component by using a horizontal polarizer. 4. Install the polarization component back onto the antenna port on the
HUAWEI Confidential Page31, Total33

2009-03-03

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

coupler.
When you install the polarization component, ensure that the arrow on the polarization component points to the H mark on the hybrid coupler.

Step 3: Remove the protective cap from the feed boom. Apply the appropriate quantity of lubricant on the gasket and the surface of the waveguide near the gasket.

Step 4: Apply appropriate anti-seize grease to the four captive screws of the coupler. Step 5: Align the antenna port of the coupler over the feed boom. Slowly let the feed boom fit in such that the four latches engage with the antenna hooks. When installing the hybrid coupler on the antenna, the ODU port identifiers marked on the hybrid coupler such as "MAIN" and "STD BY" should face upwards.

2009-03-03

HUAWEI Confidential

Page32, Total33

RTN600 Installation Quality Standard Version 1.0

Security Level: Internal use only

Step 6: Close the four latches cornerwise. Step 7: Rotate the four captive screws of the coupler about 70% and tighten them cornerwise.

2009-03-03