Académique Documents
Professionnel Documents
Culture Documents
CABLE
MEASUREMENT
v1
Strain relief kit for 2-ch cables Strain relief kit for SMPTE cables Strain relief kit for Low voltage cables
Cable retention, crimp ferrules, boot (see cable table below). Cable retention, crimp ferrules, boot, pins (see cable table below). Cable retention, crimp ferrules, boot, pins (see cable table below). opticalCON field assembly LC; multimode PC
NO2SLC-FA
CASOPTICALCON-FA
v1
HEX HEX SQUARE 6.47 5.41 6.47 5.41 9.73 2.54 1.6 7.36 8.23
HTOPT-S1
HTOPT-S2
Crimp dies to be used with HX-RBNC crimp tool only. DIE-R-OPT3A offers combined strain relief assembly for low quantities. opticalCON assembly fixture for cable retention, use together with crimping tool HX-R-BNC plus appropriate die opticalCON strain relief assembly fixture, use for large quantity production opticalCON assembly fixture for opticalCON field termination, contains fixture, user manual and technical info. Cable stripper for HYBRID cables
HTOPT-S3
HTOPT-CS
v1
FOCD-DC250
FOCD-DC125
FOCD-DW
CAS-FOMD
Measurement kit for fast system connectivity check - contains power meter SM, attenuator, 2.5mm/1.25mm adapter
FOMD-FM-MM FOMD-FM-SM
v1
Cable manufacturer
Cable jacket Gray matt Black shiny Gray matt Black shiny Gray matt
DIE
OCC
OPT3
NO2MX-R-KIT-FA
NOSR-2C-FA
DUO singlemode
OCC
5mm 0.20
OPT3
NO2SX-R-KIT-FA
NOSR-2C-FA
9.2mm 0.36
OPT4
NO2SX-R-KIT
NOSR-S1-FA
QUAD multimode
5mm 0.20
OPT3
NO4MX-R-KIT-FA
NOSR-4C-FA
QUAD single-mode
Belden
Gray matt
5mm 0.20
OPT3
NO4SX-R-KIT-FA
NOSR-4C-FA
*Not compatible to SMPTE 344M standard. Suitable for indoor (studio) camera links considering specific conditions acc. to IEC 60664-1 like pollution degree 1, over voltage category 1 and rated voltage (max 250Vac / 400Vdc).
Contact information - cable manufacturer: OCC- optical cable corporation Concourse Drive 5290 11967 Roanoke, VA 24022-1967 USA www.occfiber.com Belden Europe Edisonstraat 9 5900 AA Venlo The Netherlands www.belden.com
v1
Item number Number of fibers Fiber type Core diameter Cladding Diameter Primary coating diameter Secondary buffer diameter Numerical aperture Proof test level Wavelength Attenuation Bandwidth Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature
OC-0002036 2 multimode 50 um 125 um 500 um 900 um 0.20 100 kpsi 850 nm/1300 nm 3.0 dB/km (850 nm); 1.0 dB/km (1300 nm) 500 MHz/km 23 kg/km 5.0 mm
OC-0002401 2 multimode 50 um 125 um 500 um 900 um 0.20 100 kpsi 850 nm/ 1300 nm 3.0 dB/km (850 nm); 1.0 dB/km (1300 nm) 500 MHz/km 23 kg/km 5.0 mm
1800N 8.0 cm
1800N 8.0 cm
600N 4.0 cm 200 impacts (EIA/TIA-455-25 Military Req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C
600N 4.0 cm 200 impacts (EIA/TIA-455-25 Military Req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C
Cable surface
V jacket
C - jacket
v1
Item number Number of fibers Fiber type Core diameter Cladding Diameter Primary coating diameter Secondary buffer diameter Numerical aperture Proof test level Wavelength Attenuation Nominal zero dispersion slope Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature
OC-0002037 2 single-mode 8.3 um 125 um 500 um 900 um 0.13 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5dB/km (1550 nm) 0.092 ps/(nm2-km) 23 kg/km 5.0 mm
OC-0002402 2 single-mode 8.3 um 125 um 500 um 900 um 0.13 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5dB/km (1550 nm) 0.092 ps/(nm2-km) 23 kg/km 5.0 mm
1800 N 8.0 cm
1800 N 8.0 cm
600 N 4.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C
600 N 4.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -55 to +85 C C -70 to +85 C C
Cable surface
V jacket
C jacket
v1
Item number Number of fibers Fiber Type Core diameter Cladding diameter Fiber buffer tube diameter Wavelength Attenuation Cable weight Cable diameter Min. bend radius
Belden 7804C 2 Single-mode 9.5 um 125 um 900 um 1310 nm 0.45 dB/km 121 kg/m 9.2 mm 63.5mm
4 0.6 mm (AWG 24)/ 1.49 mm (AWG 16) 1.27 mm (AWG 24)/ 2.36 mm (AWG 16) AWG 24: 76.4 ohms/1000m AWG 16: 14.1 ohms/1000m
v1
Item number Number of fibers Fiber Type Core diameter Cladding diameter Fiber buffer tube diameter Wavelength Attenuation Cable weight Cable diameter Min. bend radius
Belden 7804C 2 Single-mode 9.5 um 125 um 900 um 1310 nm 0.45 dB/km 121 kg/m 9.2 mm 63.5mm
4 1.27 mm (AWG 24)/ 2.36 mm (AWG 16) AWG 24: 76.4 ohms/1000m AWG 16: 28.9 ohms/1000m
v1
Item number Number of fibers Fiber type Cladding Diameter Primary coating diameter Secondary buffer diameter Proof test level Wavelength Attenuation
OC-0002032 2 single-mode 125 um 245 um 900 um 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5 dB/km (1550 nm) 65 kg/km 7.3 mm
OC-0002796 2 single-mode 125 um 245 um 900 um 100 kpsi 1310 nm/ 1550 nm 0.5 dB/km (1310 nm) 0.5 dB/km (1550 nm) 65 kg/km 7.3 mm
Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Impact resistance Crush resistance Operation temperature Storage temperature
2200 N 12.0 cm
2200 N 12.0 cm
500 N 8.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -40 to +85 C C -55 to +85 C C
500 N 8.0 cm 200 impacts (EIA/TIA-455-25 military req.) 440 N/cm (TIA/EIA-455-41 military req.) -40 to +85 C C -55 to +85 C C
Cable surface
V jacket
C - jacket
v1
Item number Number of fibers Fiber type Cladding Diameter Secondary buffer diameter Wavelength Attenuation
Belden GMTT204 50/125 4 multimode 125 um 900 um 1300 nm/ 850 nm 2.3 dB/km (850 nm) 0.6 dB/km (1300 nm) 31 kg/km 5.8 mm
Belden GMTTA04 E9 4 single-mode 125 um 900 um 1300 nm/ 850 nm 0.35 dB/km (1310 nm) 0.21 dB/km (1550 nm) 31 kg/km 5.8 mm
Cable weight Cable diameter Installation: Max. tensile load Min. bend radius Operation: Max. tensile load Min. bend radius Crush resistance Operation temperature Storage temperature
1200 N 10 cm
1200 N 10 cm
Cable surface
black matt
black matt
v1
Belden 7804C: Wire color White Red Gray White Pin number 1 2 3 4
OCC OC-0002432 OCC OC-0002796 Wire color Black/White White Pin number 1 4
v1
Single-mode
Zeroing
Measurement
Multimode
Zeroing
LAUNCH FIBRE 500 m / 50 m FC-ADAPTER NEUTRIK NO2-4FD[1]
MEASURING CABLE
FC-ADAPTER
MEASURING CABLE
MM
SM
IN
Measurement
LAUNCH FIBRE 500 m / 50 m FC-ADAPTER NEUTRIK NO2-4FD[1] NEUTRIK NO2-4FD[2] FC-ADAPTER
MEASURING CABLE MEASURING CABLE
MM
SM
IN
v1
www.neutrik.com
BDA 264
v1