Vous êtes sur la page 1sur 5

Project 5 Variant1

Results of annual simulation

Installed collector power: Installed solar surface area (gross): Irradiation on to collector surface (active): Energy delivered by collectors: Energy delivered by collector loop: DHW heating energy supply: Solar contribution to DHW: Energy from auxiliary heating: Natural gas (H) savings: CO2 emissions avoided: DHW solar fraction: Fractional energy savings (EN 12976): System efficiency:

70.28 kW 100.4 m 199.66 MWh 109.52 MWh 109.21 MWh 134.62 MWh 109.21 MWh 35.54 MWh

2,124.02 kWh/m 1,165.15 kWh/m 1,161.77 kWh/m

13,436.4 m 28,413.26 kg 75.4 % 75.3 % 54.7 %

T*SOL Pro 5.0 (R 2)

Page 1

26/03/2011

Project 5 Variant1

Site data
Climate data Location: Climate data record: Total annual global irradiation: Latitude: Longitude:
.

Abu Dhabi "Abu Dhabi" 2034.335 kWh/m 24.47 -54.42

Domestic hot water Average daily consumption: Desired temperature: Consumption profile: Cold water temperature: Circulation:
.

10 m 60 C Multiple dwelling (VDI 6002) February:20 C / August:35 C Yes

System components
Collector loop Manufacturer: Type: Number: Total gross surface area: Total active solar surface area: Tilt angle: Azimuth:
.

Vaillant GmbH auroTHERM VFK 145V 40.00 100.4 m 94 m 30 0

Dual coil indirect DHW tank Manufacturer: Type: Volume:


.

Vaillant 4 x VIH S 2000 4 x 2000 l

Auxiliary heating Manufacturer: Type: Nominal output: Legend No boilers present No boilers present 0 kW

With test report Solar Keymark

T*SOL Pro 5.0 (R 2)

Page 2

26/03/2011

Project 5 Variant1

Solar energy consumption as percentage of total consumption

Daily maximum collector temperature

These calculations were carried out by T*SOL Pro 5.0 - the simulation program for solar thermal heating systems. The results are determined from the computation of a mathematical model with variable time steps of up to 6 minutes. Actual yields can deviate from these values due to

T*SOL Pro 5.0 (R 2)

Page 3

26/03/2011

Project 5 Variant1

Energy balance schematic

Legend

1 1.1 1.2 2 2.1 2.5 2.6 3.1 3.2 6.5 9

Irradiation on to collector surface (active) Optical collector losses Thermal collector losses Energy from collector array Solar energy to storage tank Internal piping losses External piping losses Tank losses Circulation losses Electric element DHW energy from tank

0 kWh 56 MWh 34 MWh 110 MWh 109 MWh 87 kWh 231 kWh 9,219 kWh 929 kWh 36 MWh 135 MWh

T*SOL Pro 5.0 (R 2)

Page 4

26/03/2011

Project 5 Variant1

Glossary 1 Irradiation on to collector surface (active) Solar energy irradiated onto tilted collector area (active surface area) 1.1 Optical collector losses Reflection and other losses 1.2 Thermal collector losses Heat conduction and other losses 2 Energy from collector array Energy output at collector array outlet (i.e. before piping) 2.1 Solar energy to storage tank Energy from collector loop to storage tank (minus piping losses) 2.5 Internal piping losses Internal piping losses 2.6 External piping losses External piping losses 3.1 Tank losses Heat losses via surface area 3.2 Circulation losses Circulation piping losses 6.5 Electric element Energy from electric water heater element 9 DHW energy from tank Heat from tank (exluding circulation) for DHW consumption

T*SOL Pro 5.0 (R 2)

Page 5

26/03/2011

Report-/Druckmodul List & Label Version 13: Copyright combit GmbH 1991-2007