Vous êtes sur la page 1sur 2

Product Safety Data Sheet

Product: WorkCentre M940 / M950

XEROX
PSDS No.: 0866 ISSUE DATE: 03/14/01 REV. DATE: Emergency No. (585) 422-2177 EH&S Inquiries (800) 828-6571

Section I - Product Identification Manufacturer's Name Xerox Corporation Manufacturer's Address Rochester, N.Y. Product Designation WorkCentre M940 / M950 Section II - Electrical Information Line Voltage Line Current (Volts) (Amps) 110-117 0.85 Line Cord/Plug Specification Equipped with Appliance coupler Detachable Cord, Two wire + Ground NEMA 5-15P/ -20P Agency Approval UL E 145607 PH cUL E 145607 PH Section III - Supplies Black Cyan Magenta Yellow Color Printhead Xerox Part No. 8R7969 8R7972 8R7973 8R7974 8R7970

Product Identifier: YPA-3/YPA-4

Freq. (Hertz) 50/60

Branch Cir. Protection (Amps) 15 Power Consumption(Watts)* Running: 34.0 Standby: 18.0 Power Saver: 6.0

Material Safety Data Sheet Article ** (F9) Article ** (F9) Article ** (F9) Article ** (F9) Article ** (F9)

Section IV - Environmental Information Product Size (Centimeters / Inches) D: 40.4 / 15.9 W: 48.0 / 18.9 H: 35.3 / 11.2 Heat Emission* (BTU/HR) Running: 115.6 Standby: 61.2 Power Saver: 54.5 Environmental Limitations Min Max Relative Humidity (%)20 80 Ambient Temp. (oC) 10 32.5

Floor Space Requirements (Meters / Feet) N/A - Desktop unit

Weight (K Grams / Lbs.) M940- 12 / 26.4 M950- 14 / 30.8

* Based on a five minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA (Section II (2) ) www.xerox.com Reference About Xerox

Product: WorkCentre M940 / M950 Section V - Emission/Exposure Information* Light Source N/A Electromagnetic Emissions US FCC: Class B Canada DOC: Class B Audible Noise Run 46 dB(A) Standby 17 dB(A) Impulse 54 dB(A) Ozone N/A

PSDS No: 0866

TLV 85.0 dB(A)

Total Dust N/A

Section VI - Product Recycling and Disposal This product may contain lead, mercury and other materials whose disposal may be regulated due to environmental considerations. For recycling and disposal information, contact your local authorities. In the United States, you may also refer to the Electronic Industries Alliance web site: www.eiae.org. For information on Xerox's worldwide equipment return and recycling programs, visit www.xerox.com (refer to "About Xerox" section).

* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (TimeWeighted Average) for a normal eight-hour workday.

All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions. www.xerox.com Reference About Xerox