SYSMAC CJ-series CJ2M CPU Units

CJ2M-CPU3@/-CPU1@
CSM_CJ2M-CPU3__-CPU1_DS_E_1_1

Since 2001, CJ1M-series PLCs are in control of a wide variety of applications worldwide. The accumulated experience and advancements in technology now result in CJ2M; fully compatible, yet fully new.
Increased performance, and increased memory capacity Up to 40 I/O units on any CPU USB for plug-and-play access to the PLC All models available with or without Ethernet port Choice of serial port plug-in modules User-friendly programming, faster debugging
CJ2M-CPU3@ CJ2M-CPU1@

Features
Five variations in program capacity from 5K steps to 60K steps; scale the CPU to your application needs. Faster processors; logic instruction execution time is reduced to 40 ns, floating point trigonometrics in less than 1 s. Faster Function Block calls and execution, faster interrupt handling, less overhead time. Added execution memory for Function Blocks allows structured, object-oriented programming even in entry-level CPUs. General-purpose Ethernet port supports EtherNet/IP tag-based data links, connection to Support Software, communications between PLCs, FTP data transfers, and more (CJ2M-CPU3@). Standard USB port on all models allows Support Software to connect directly through standard USB cable. A Serial Option Module can be mounted to add RS-232C or RS-422A/485 communications ports (CJ2M-CPU3@). Compatible with all existing CJ1 power supply-, I/O-, control- and communication units.

CJ2M-CPU3@/-CPU1@

Ordering Information
International Standards The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2 Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representative for further details and applicable conditions for these standards.

CJ2M CPU Units (Built-in EtherNet/IP)


Specifications Product name I/O capacity/ Mountable Units (Expansion Racks) Program capacity Data memory capacity LD instruction execution time EtherNet/IP function Option board slot Current consumption (A) Model 5V 24 V Standards

CJ2M (Built-in EtherNet/IP) CPU Units

2,560 points/ 40 Units (3 Expansion Racks max.)

60K steps 160K words (DM: 32K words, EM: 32K words 30K steps 4 banks) 20K steps 160K words (DM: 32K words, 10K steps EM: 32K words 1 bank) 5K steps 0.04 s YES YES 0.7 (See note.)

CJ2M-CPU35 CJ2M-CPU34 CJ2M-CPU33 UC1, CE CJ2M-CPU32 CJ2M-CPU31

Note: Add 0.005A, 0.030A and 0.075A when using Serial Communications Option Boards (CP1W-CIF01/11/12), respectively.

CJ2M CPU Units


Specifications Product name I/O capacity/ Mountable Units (Expansion Racks) Program capacity Data memory capacity LD instruction execution time EtherNet/IP function Option board slot Current consumption (A) Model 5V 24 V Standards

CJ2M CPU Units 2,560 points/ 40 Units (3 Expansion Racks max.)

60K steps 160K words (DM: 32K words, EM: 32K words 30K steps 4 banks) 20K steps 160K words (DM: 32K words, 10K steps EM: 32K words 1 bank) 5K steps 0.04 s 0.5 (See note.)

CJ2M-CPU15 CJ2M-CPU14 CJ2M-CPU13 UC1, CE CJ2M-CPU12 CJ2M-CPU11

Note: Add 0.15A when using NT-AL001 RS-232C/RS-422A Adapters. Add 0.04 A when using CJ1W-CIF11 RS-422A Adapters.

Serial Communications Option Boards (Only CJ2M-CPU3@)


The serial communications port can be equipped by installing the serial communications option board to the option board slot in front of CPU unit.
Product name RS-232C Option Board Specifications One RS-232C port Connector: D-Sub, 9 pin, female Maximum transmission distance: 15m One RS-232C connector (D-Sub, 9 pin, male) is included. (Plug: XM2A-0901, Hood: XM2S-0911-E) Model Standards

CP1W-CIF01 UC1, N, L, CE CP1W-CIF11

RS-422A/485 Option Board

One RS-422A/485 port Terminal block: using ferrules Maximum transmission distance: 50m

RS-422A/485 Isolated-type Option Board

One RS-422A/485 port (Isolated) Terminal block: using ferrules Maximum transmission distance: 500m

CP1W-CIF12

N, L, CE

Note: It is not possible to use a CP-series Ethernet Option Board (CP1W-CIF41), LCD Option Board (CP1W-DAM01) with a CJ2M CPU Unit.

CJ2M-CPU3@/-CPU1@

Accessories
The following accessories come with CPU Unit:
Item Battery End Cover End Plate Serial Port (RS-232C) Connector (see note) CJ1W-BAT01 CJ1W-TER01 (necessary to be mounted at the right end of CPU Rack) PFP-M (2 pcs) Connector set for serial port connection (D-SUB 9-pin male connector) Specification

Note: Connector is not provided with CJ2M-CPU3@.

General Specifications
Item Enclosure Grounding CPU Rack Dimensions Weight Current Consumption Ambient Operating Temperature Ambient Operating Humidity Atmosphere Ambient Storage Temperature Altitude Pollution Degree Use Environment Noise Immunity Overvoltage Category EMC Immunity Level Vibration Resistance CJ2MCPU1@ Mounted in a panel Less than 100 90 mm 75 mm 31 mm 130 g or less 5 VDC, 0.5 A 0 to 55C 10% to 90% Must be free from corrosive gases. 20 to 70C (excluding battery) 2,000 m or less 2 or less: Conforms to JIS B3502 and IEC 61131-2. 2 kV on power supply line (Conforms to IEC 61000-4-4.) Category II: Conforms to JIS B3502 and IEC 61131-2. Zone B Conforms to IEC60068-2-6 5 to 8.4 Hz with 3.5-mm amplitude, 8.4 to 150 Hz Acceleration of 9.8 m/s2 for 100 min in X, Y, and Z directions (10 sweeps of 10 min each = 100 min total) Conforms to IEC60068-2-27 147 m/s2, 3 times in X, Y, and Z directions (100 m/s2 for Relay Output Units) 5 years at 25C CJ1W-BAT01 Conforms to cULus and EC Directives. 90 mm 75 mm 62 mm 190 g or less (see note) 5 VDC, 0.7 A CPU3@

Shock Resistance Battery Applicable Standards Life Model

Note: Without a Serial Option Board.

CJ2M-CPU3@/-CPU1@

Performance Specifications
Items User Memory I/O Bits Overhead Processing Time CJ2MCPU11/31 5K steps 2,560 bits Normal Mode: CJ2M-CPU3@: 270 s (If tag data links are used with EtherNet/IP, add the following to the above time: 100 s + Number of transferred words 1.8 s) CJ2M-CPU1@: 160 s Basic Instructions : 0.04 s min. Special Instructions : 0.06 s min. Interrupt task startup time: 31 s Return time to cyclic task : 10 s Minimum time interval : 0.4 ms (set in 0.1 ms increments) Interrupt task startup time: 30 s Return time to cyclic task : 11 s Total per CPU Rack or Expansion Rack: 10 Units max.; Total per PLC: 40 Units max. No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Units for up to 96 unit numbers can be mounted. (Unit numbers run from 0 to 95. Units are allocated between 1 and 8 unit numbers.) CJ2M-CPU3@: 15 Units max. CJ2M-CPU1@: 16 Units max. Slots 0 to 4 on CPU Rack 3 max. 2,560 bits (160 words) : Words CIO 0000 to CIO 0159 3,200 bits (200 words) : Words CIO 1000 to CIO 1199 6,400 bits (400 words) : Words CIO 1500 to CIO 1899 15,360 bits (960 words): Words CIO 2000 to CIO 2959 1,440 bits (90 words) : Words CIO 3100 to CIO 3189 9,600 bits (600 words) : Words CIO 3200 to CIO 3799 3,200 bits (200 words) : Words CIO 1300 to CIO 1499 37,504 bits (2,344 words): Words CIO 3800 to CIO 6143 Cannot be used for external I/O. 8,192 bits (512 words): Words W000 to W511 Cannot be used for external I/O. 8,192 bits (512 words): Words H000 to H511 Bits in this area maintain their ON/OFF status when PLC is turned OFF or operating mode is changed. Words H512 to H1535: These words can be used only for function blocks. They can be used only for function block instances (i.e., they are allocated only for internal variables in function blocks). Read-only: 31,744 bits (1,984 words) 7,168 bits (448 words): Words A0 to A447 24,576 bits (1,536 words): Words A10000 to A11535 * Read/write: 16,384 bits (1,024 words) in words A448 to A1471 * * A960 to A1471 and A10000 to A11535 cannot be accessed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. 16 bits: TR0 to TR15 4,096 timer numbers (T0000 to T4095 (separate from counters)) 4,096 counter numbers (C0000 to C4095 (separate from timers)) 32k words * DM Area words for Special I/O Units: D20000 to D29599 (100 words 96 Units) DM Area words for CPU Bus Units: D30000 to D31599 (100 words 16 Units) * Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. 32k words/bank 4 banks max.: E00_00000 to E3_32767 max. * * Bits in the EM Area can be addressed either by bit or by word. These bits cannot be addressed by CPU Bus Units, Special I/O Units, PTs, and Support Software that do not specifically support the CJ2 CPU Units. 32K words 1 bank Force-S/R Enabled Banks *1 Index Registers Cyclic Task Flag Area Memory Card Bank 0 hex 32K words 4 banks Bank 0 to 3 hex CPU12/32 10K steps CPU13/33 20K steps CPU14/34 30K steps CPU15/35 60K steps

Processing Speed

Execution Time I/O Interrupts and External Interrupts Interrupts Scheduled Interrupts

Maximum Number of Connectable Units Basic I/O Units Special I/O Units CPU Bus Units Slots for which interrupts can be used Maximum Number of Expansion Racks I/O Area Link Area CPU Bus Unit Area CIO Area Special I/O Unit Area Serial PLC Link Words DeviceNet Area Internal I/O Area Work Area

Synchronous Data Refresh Area

Holding Area

Auxiliary Area

Temporary Area Timer Area Counter Area

DM Area

EM Area

IR0 to IR15 These are special registers for storing PLC memory addresses for indirect addressing. (Index Registers can be set so that they are unique in each task or so that they are shared by all tasks.) 128 flags 128 MB, 256 MB, or 512 MB PROGRAM Mode: Programs are not executed. Preparations can be executed prior to program execution in this mode. MONITOR Mode: Programs are executed, and some operations, such as online editing, and changes to present values in I/O memory, are enabled in this mode. RUN Mode: Programs are executed. This is the normal operating mode.

Operating Modes

*1. Force-setting/resetting bits in the EM Area is possible only for banks specified for the EM Area force-set/reset function.

CJ2M-CPU3@/-CPU1@

Items Execution Mode Programming Languages Maximum number of definitions Maximum number of instances

CJ2MCPU11/31 Normal Mode Ladder Logic (LD), Sequential Function Charts (SFC), Structured Text (ST), and Instruction Lists (IL) 256 256 20K steps Cyclic tasks Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and external interrupt tasks) Cyclic tasks: 128 Interrupt tasks: 256 (Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total number of cyclic tasks is actually 384 max.) Local symbols: Can be used only within a single task in the PLC. Global symbols: Can be used in all tasks in the PLC. Network symbols (tags)*: I/O memory in the CPU Unit can be externally accessed using symbols, depending on parameter settings. * Supported only by the CJ2M-CPU3@. BOOL (bit) UINT (one-word unsigned binary) UDINT (two-word unsigned binary) ULINT (four-word unsigned binary) INT (one-word signed binary) DINT (two-word signed binary) LINT (four-word signed binary) UINT BCD (one-word unsigned BCD) *2 UDINT BCD (two-word unsigned BCD) *2 ULINT BCD (four-word unsigned BCD) *2 REAL (two-word floating-point) LREAL (four-word floating-point) CHANNEL (word) *2 NUMBER (constant or number) *2 WORD (one-word hexadecimal) DWORD (two-word hexadecimal) LWORD (four-word hexadecimal) STRING (1 to 255 ASCII characters) TIMER (timer) *3 COUNTER (counter) *3 User defined data types (data structures) 2,048 2,048 CPU12/32 CPU13/33 CPU14/34 CPU15/35

Function Blocks

FB Program Area Type of Tasks Tasks Number of Tasks

Type of Symbols

Data Type of Symbols Symbols (Variables)

Maximum Size of Symbol Number of Array Elements Number of Registrable Network Symbols (Tags) *4 Length of Network Symbol (Tag) Name *4 Encoding of Network Symbols (Tags) *4 Memory Capacity Number of Samplings Sampling Cycle Data Tracing Trigger Conditions

32k words 32,000 elements max. 2,000 max. 255 bytes max. UTF-8 8,000 words (Up to 32k words 4 banks when EM is specified in CX-Programmer) Bits = 31, one-word data =16, two-word data = 8, four-word data = 4 1 to 2,550 ms (Unit: 1 ms) ON/OFF of specified bit Data comparison of specified word Data size: 1 word, 2 words, 4 words Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (), Less Than (<), Less Than or Equals (), Not Equal () 32,768 to +32,767 ms Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.) EM file memory (Part of the EM Area can be converted for use as file memory.)

Array Symbols (Array Variables) One-dimensional arrays

Delay Value File Memory Source/ Comment Memory Function block program memory, comment file, program indey file, symbol tables

Capacity: 1 Mbytes

*2. Cannot be used in Function blocks. *3. Can be used only in Function blocks. *4. Supported only by the CJ2M-CPU3@.

CJ2M-CPU3@/-CPU1@

Item Logical Ports for Communications CIP Communications Specification Peripheral (USB) Port Baud Rate Transmission Distance Logical Ports Extended Logical Ports Class 3 (Connection Type) UCMM (Nonconnection Type)

CJ2MCPU11/31 CPU12/32 CPU13/33 CPU14/34 CPU15/35 8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.) 64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.) Number of connections: 64 Maximum number of clients that can communicate at the same time: 32 Maximum number of servers that can communicate at the same time: 40 USB 2.0-compliant B-type connector 12 Mbps max. 5 m max. CJ2M-CPU1@ interface: Conforms to EIA RS-232C. CJ2M-CPU3@: No serial ports with default system One of the following Serial Option Boards can be mounted. CP1W-CIF01 RS-232C Option Board CP1W-CIF11 RS-422A/485 Option Board (not isolated, max. transmission distance: 50 m) CP1W-CIF12 RS-422A/485 Option Board (isolated, max. transmission distance: 500 m) Half-duplex Start-stop 0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps) 15 m max. CSMA/CD Baseband Star 100 Mbps (100Base-TX) Shielded twisted-pair (STP) cable; Categories: 5, 5e 100 m (between hub and node) No restrictions if switching hub is used.

Serial Port

Communications Method Synchronization Method Baud Rate Transmission Distance EtherNet/IP Port Transmission Specifications Media Access Method Modulation Transmission Paths Baud Rate Transmission Media Transmission Distance Number of Cascade Connections

CIP Communications: Tag Data Links Communications Number of Connections Packet Interval (Refresh period) 32 1 to 10,000 ms (Unit: 0.5 ms) Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.) 32 CIO, DM, EM, HR, WR, and Network symboles 8 (Seven tags if PLC status is included in the segment.) 640 words 20 words (Data is synchronized within each connection.) 32 (1 connection = 1 segment) 20 words (One word is used when PLC status is included in the segment.) Output/send (CPU Unit to EtherNet/IP): 32 Input/receive (EtherNet/IP to CPU Unit): 32 Output/send (CPU to EtherNet/IP) : 640 words Input/receive (EtherNet/IP to CPU): 640 words OK *7 OK Number of connections: 128 Maximum number of clients that can communicate at the same time : 16 Maximum number of servers that can communicate at the same time: 16 OK (CIP routing is enabled for the following remote Units: CJ1W-EIP21, CJ2H-CPU6@-EIP, CJ2MCPU3@, and CS1W-EIP21.) OK 16 connections max. Conforms to A5. 10Base-T/100Base-TX Auto Negotiation/Fixed Setting

Permissible Communications Band 3,000 pps *5 Number of Registerable Tag Type of Tags Number of Tags per Connection Maximum Link Data Size per Node Maximum Data Size per Connection Communications Specifications Number of Registrable Tag Set Maximum Tag Set Size Maximum Number of Tags Refreshable in a Single Cycle of CPU Unit *6 Data Size Refreshable in a Single Cycle of CPU Unit *6 Change of Tag Data Link Parameter Settings during Operation Multi-cast Packet Filter *8 CIP Communications: Explicit Messages Class 3 (Connection Type) UCMM (Non-connection Type) CIP Routing FINS Communications FINS/UDP FINS/TCP EtherNet/IP Conformance Test EtherNet/IP Interface

CJ2M-CPU3@/-CPU1@
*5. "Packets per second" is the number of communications packets that can be processed per second. *6. If the maximum number is exceeded, refreshing will require more than one CPU Unit cycle. *7. When changing parameters, however, the EtherNet/IP port where the change is made will be restarted. In addition, a timeout will temporarily occur at the other node that was communicating with that port, and it will then recover automatically. *8. The EtherNet/IP port supports an IGMP client, so unnecessary multicast packets are filtered by using a switching hub that supports IGMP snooping.

Function Specifications
Functions Minimum Cycle Time Cycle Time Management Cycle Time Monitoring Background Processing Basic I/O Units, Special I/O Units, and CPU Bus Units Cyclic Refreshing I/O Immediate Refreshing Refreshing Refreshing by IORF Unit Recognition at Startup Input Response Time Setting Load OFF Function Basic I/O Unit Status Monitoring Reading/writing data using instructions for specific Units Special I/O Units and CPU Bus Units Unit Restart Bits to Restart Units Description A minimum cycle time can be set. (0.2 to 32,000 ms; Unit: 0.1 ms) The minimum cycle time setting can be changed in MONITOR mode. The cycle time is monitored. (0.01 to 40,000 ms; Unit: 0.01 ms) Instructions with long execution times can be executed over multiple cycles to prevent fluctuations in the cycle time. Cyclic refreshing of Basic I/O Units, Special I/O Units, and CPU Bus Units I/O refreshing by immediate refreshing instructions I/O refreshing by IORF instruction The number of units recognized when the power is turned ON is displayed. The input response times can be set for Basic I/O Units. The response time can be increased to reduce the effects of chattering and noise at input contacts. The response time can be decreased to enable detecting shorter input pulses. All of the outputs on Basic I/O Units can be turned OFF when an error occurs in RUN or MONITOR mode. Alarm information can be read from Basic I/O Units and the number of Units recognized can be read. Special instructions can be used to read/write required data for specific Units at high speed. A Special I/O Unit or CPU Bus Unit can be restarted. I/O words can be automatically allocated to the Basic I/O Units that are connected in the PLC to start operation automatically without registering Units into I/O tables. The current unit configuration can be registered in I/O tables to prevent it from being changed, to reserve words, and to set words. The first words allocated to a Units on the Racks can be set.

Basic I/O Units Unit (I/O) Management

Automatic I/O Allocation at Startup Configuration Management I/O Table Creation Rack/Slot First Word Settings

The status of I/O memory can be held when the operating mode is changed or power is Holding I/O Memory when Changing Operating Modes turned ON. The forced-set/reset status can be held when the operating mode is changed or power is turned ON. File Memory Memory Management Built-in Flash Memory EM File Function Storing Comments EM Configuration Automatic File Transfer at Startup Memory Cards Program Replacement during PLC Operation Function for Reading and Writing Data from a Memory Card Files (such as program files, data files, and symbol table files) can be stored in Memory Card, EM File Memory, or Comment Memory. The user program and Parameter Area can be backed up to an internal flash memory when they are transferred to the CPU Unit. Parts of the EM Area can be treated as file memory. I/O comments can be stored as symbol table files in a Memory Card, EM file memory, or comment memory. EM Area can be set as trace memory or EM file memory. A program file and parameter files can be read from a Memory Card when the power is turned ON. The whole user program can be read from a Memory Card to CPU Unit during operation. Data in I/O memory in the CPU Unit can be written to a Memory Card in CSV/TXT format. Data in CSV/TXT format in the Memory Card can be read to I/O memory in the CPU Unit.

CJ2M-CPU3@/-CPU1@

Function Communications Peripheral (USB) Port Peripheral Bus

Description Bus for communications with various kinds of Support Software running on a personal computer. High-speed communications are supported. Application is possible when a Serial Communications Option Board is mounted. Host Link commands or FINS commands placed between Host Link headers and terminators can be sent from a host computer or PT to read/write I/O memory, read/control the operating mode, and perform other operations for PLC. I/O instructions for communications ports (such as TXD/RXD instructions) can be used for data transfer with peripheral devices such as bar code readers and printers. I/O memory in the PLC can be allocated and directly linked to various PT functions, including status control areas, status notification areas, touch switches, lamps, memory tables, and other objects. Bus for communications with various kinds of Support Software running on a personal computer. High-speed communications are supported. This gateway enables receiving and automatically converting FINS to the CompoWay/F. Data is exchanged between CPU Units using serial ports without communications programming. PTs set to the 1:N NT Link protocol can be included in the network. 100Base-TX/10Base-T Protocols: TCP/IP, UDP, ARP, ICMP (ping only), BOOTP Applications: FINS, CIP, POP3, SMTP, SNTP, DNS (Client), FTP (Server) Programless cyclic data exchanges with the devices on the EtherNet/IP network. Any CIP commands can be received from the devices on the EtherNet/IP network. Any FINS commands can be transferred with the devices on the EtherNet/IP network. Tasks can be executed at a specified interval (minimum of 0.2 ms, Unit: 0.1 ms). When MSKS(690) is executed, the internal timer is restarted and the time to first interrupt is set to a fixed value. MSKS(690) can be used to read the time that has elapsed until the schedule interrupt is started or since the previous scheduled interrupt. A task can be executed when CPU Unit's power turns OFF. A task can be executed when an input signal is input to an Interrupt Input Unit. A task can be executed when interrupts are requested from a Special I/O Unit or a CPU Bus Unit. Clock data is stored in memory. Accuracy (Accuracy depends on the temperature.) Ambient temperature of 55C : 3.5 to +0.5 min error per month Ambient temperature of 25C : 1.5 to +1.5 min error per month Ambient temperature of 0C : 3 to +1 min error per month The time when operating mode was last changed to RUN mode or MONITOR mode is stored. The last time a fatal error occurred or the last time the operating mode was changed to PROGRAM mode is stored. The time when the power was turned ON is stored. The time when the power is turned OFF is stored. The total time that the PLC has been ON is stored in increments of 10 hours. A history of the times when the power was turned ON is stored. The time that the user program was last overwritten is stored. The time when the Parameter Area was overwritten is stored. Holding Area data, DM Area data, EM Area data, Counter Completion Flags, and counter present values are held even when power is turned OFF. CIO Area, Work Area, some Auxiliary Area data, and Timer Completion Flags, timer present values, index registers, and data registers can be protected by turning ON the IOM Hold Bit in the Auxiliary Area, and by also setting the IOM Hold Bit to Hold in the PLC Setup. The detection time for power interruptions can be set. AC power supply: 10 to 25 ms (variable) DC power supply: 2 to 5 ms (CJ1W-PD022) or 2 to 20 ms (CJ1W-PD025) The detection of power interruptions can be delayed: 0 to 10 ms (Not supported by the CJ1W-PD022.) The number of times power has been interrupted is counted.

Serial Port (Option) *9 Host Link (SYSWAY) Communications No-protocol Communications NT Link Communications Peripheral Bus Serial Gateway Serial PLC Links EtherNet/IP Port *10 CIP Tag Data Links Communications Message Communications Service FINS Communications Message Communications Service Scheduled Interrupts Resetting and restarting with MSKS(690) Reading present value of internal timer with MSKS(690) Power OFF Interrupts I/O Interrupt Tasks External Interrupt Tasks

Interrupt

Clock Function

Operation Start Time Storage Operation Stop Time Storage Clock Startup Time Storage Power Interruption Time Storage Total Power ON Time Calculation Power ON Clock Data Storage User Program Overwritten Time Storage Parameter Date Storage

Memory Protection Power Supply Management Power OFF Detection Time Setting Power OFF Detection Delay Time Number of Power Interruptions Counter

*9.A Serial Option Board is required to use a serial port for the CJ2M-CPU3@ CJ2M CPU Unit. *10.Supported only by the CJ2M-CPU3@.

CJ2M-CPU3@/-CPU1@

Function Function Blocks Languages in Function Block Definitions Online Editing Force-Set/Reset Differentiate Monitoring Data Tracing Debugging Continuous Tracing Automatically starting tracing when operation starts Storing Location of Error when an Error Occurs Program Check Error Log CPU Error Detection User-defined Failure Diagnosis Load OFF Function RUN Output Basic I/O Load Short-circuit Detection Failure Point Detection CPU Standby Detection Ladder programming or structured text

Description Standard programming can be encapsulated as function blocks. The program can be changed during operation (in MONITOR or PROGRAM mode), except for block programming areas. Specified bits can be set or reset. Force-set/reset to the EM Area is enabled by specifying a start bank in parameter setting. ON/OFF changes in specified bits can be monitored. The specified I/O memory data can be stored in the trace memory in the CPU Unit. The triggers can be set. The trace data can be uploaded during data tracing using CX-Programmer, which enables continuously logging the data by constantly uploading the trace data. Data tracing can be automatically started when operation is started (i.e., when the operating mode is changed from PROGRAM mode to MONITOR or RUN mode). The location and task number where execution stopped for a program error is recorded. The programs can be checked for items such as no END instruction and FALS/FAL errors at startup. A function is provided to store predefined error codes in CPU Unit, error information, and time at which the error occurred. CPU Unit WDT errors are detected. Errors can be generated for user-specified conditions: Non-fatal errors (FAL) and fatal errors (FALS). Program section time diagnosis and program section logic diagnosis are supported (FPD instruction). This function turns OFF all outputs from Output Units when an error occurs. The RUN output from the CJ1W-PA205R turns ON while CPU Unit is in RUN mode or MONITOR mode. This function provides alarm information from Basic I/O Units that have load short-circuit protection. The time and logic of an instruction block can be analyzes using the FPD instruction. This function indicates when the CPU Unit is on standby because all Special I/O Units and CPU Bus Units have not been recognized at the startup in RUN or MONITOR mode.

System FAL Error Detection This function generates a non-fatal (FAL) error when the user-defined conditions are met in (User-defined non-fatal error) program. Duplicate Refreshing Error Detection Backup Memory Error Detection Selfdiagnosis and Restoration PLC Setup Error Detection Non-fatal Error Detection CPU Bus Unit Error Detection Special I/O Unit Error Detection Tag Memory Error Detection *11 Battery Error Detection CPU Bus Unit Setting Error Detection Special I/O Unit Setting Error Detection Memory Error Detection I/O Bus Error Detection Unit/Rack Number Duplication Error Too Many I/O Points Error Detection I/O Setting Error Detection This function detects an error when an immediate refreshing Instruction in an interrupt task is competing with I/O refreshing of a cyclic task. This function detects errors in the memory backup of the user programs and parameter area (backup memory). This function detects setting errors in the PLC Setup. This function detects an error when there is an error in data exchange between the CPU Unit and a CPU Bus Unit. This function detects an error when there is an error in data exchange between the CPU Unit and a Special I/O Unit. This function detects errors in tag memory. This function detects an error when a battery is not connected to the CPU Unit or when the battery voltage drops. This function detects an error when the model of a CPU Bus Unit in the registered I/O tables does not agree with the model that is actually mounted in the PLC. This function detects an error when the model of a Special I/O Unit in the registered I/O tables does not agree with the model of Unit that is actually mounted. This function detects errors that occur in memory of the CPU Unit. This function detects when an error occurs in data transfers between the Units mounted in Rack slots and the CPU Unit and detects when the End Cover is not connected to the CPU Rack or an Expansion Rack. This function detects an error when the same unit number is set for two or more Units, the same word is allocated to two or more Basic I/O Units, or the same rack number is set for two or more Racks. This function detects an error when the total number of I/O points set in the I/O tables or the number of Units per Rack exceeds the specified range. This function detects an error when the number of Units in the registered I/O tables does not agree with the actual number of Units that is mounted, or an Interrupt Unit has been connected in the wrong position, i.e., not in slot 0 to 4.
.

Basic I/O Unit Error Detection This function detects the errors in Basic I/O Units.

Option Board Error Detection *11 This function detects the errors in Serial Option Board mounting status.

Fatal Error Detection

*11.Supported only by the CJ2M-CPU3@.

CJ2M-CPU3@/-CPU1@

Function Program Error Detection Instruction Processing Error Detection Indirect DM/EM BCD Error Detection Illegal Area Access Error Detection No END Error Detection Fatal Error Detection Selfdiagnosis and Restoration Task Error Detection Differentiation Overflow Error Detection Invalid Instruction Error Detection User Program Area Overflow Error Detection Cycle Time Exceeded Error Detection Fatal Error Detection (Continued from previous page) System FALS Error Detection (User-defined Fatal Error) Version Error Detection Memory Card Transfer Error Detection

Description This function detects errors in programs. This function detects an error when the given data value is invalid when executing an instruction, or execution of instruction between tasks was attempted. This function detects an error when an indirect DM/EM address in BCD mode is not BCD. This function detects an error when an attempt is made to access an illegal area with an instruction operand. This function detects an error when there is no END instruction at the end of the program. This function detects an error when there are no tasks that can be executed in a cycle, there is no program for a task, or the execution condition for an interrupt task was met but there is no interrupt task with the specified number. This function detects an error when too many differentiated instructions are entered or deleted during online editing (131,072 times or more). This function detects an error when an attempt is made to execute an instruction that is not defined in the system. This function detects an error when instruction data is stored after the last address in user program area. This function monitors the cycle time (10 to 40,000 ms) and stops the operation when the set value is exceeded. This function generates a fatal (FALS) error when the user-defined conditions are met in program. This function detects an error when a user program includes a function that is not supported by the current unit version. This function detects an error when the automatic file transfer from Memory Card fails at startup. This function collectively backs up the data in CPU Unit (user programs, parameters, and I/O memory) and internal backup data in the I/O Units. A function that allows the PLC to use Network Communications Instruction to send required FINS commands to a computer connected via a Host Link Host Link communications can be used for remote programming and remote monitoring through a Controller Link, Ethernet, DeviceNet, or SYSMAC LINK Network. Communications across network layers can be performed. Controller Link or Ethernet : 8 layers DeviceNet or SYSMAC LINK : 3 layers This function enables automatically connecting to the PLC online when the CX-Programmer is directly connected by a serial connection (peripheral (USB) port or serial port). This function enables connecting the CX-Programmer online to a PLC that is connected via an EtherNet/IP network. This function protects reading and displaying programs and tasks using passwords. Write protection: Set using the DIP switch. Read protection: Set a password using the CX-Programmer. This function prohibits writing by using FINS commands sent over the network. This function allows the users to give any names to the Units. Names are verified at online connection to prevent wrong connection This function sets operation protection by identifying hardware using the user programs according to lot numbers stored in the Auxiliary Area.

Simple Backup Function Unsolicited Communications

Maintenance

Remote Programming and Monitoring

Automatic Online Connection via Network

Direct Serial Connection Via Networks

Read Protection using Password FINS Write Protection Unit Name Function Hardware ID Using Lot Numbers

Security

Unit Versions
Units CJ2M CPU Units CJ2M-CPU3@ CJ2M-CPU1@ Models Unit version CPU: Unit version 1.0 EIP : Unit version 2.0 CPU: Unit version 1.0

10

CJ2M-CPU3@/-CPU1@

Unit Versions and Programming Devices


The following tables show the relationship between unit versions and CX-Programmer versions.

Unit Versions and Programming Devices


Required Programming Device CPU Unit CJ2M-CPU@@ Unit version 1.0 Functions Ver. 9.0 or lower Functions for unit version 1.0 CX-Programmer Ver. 9.1 or higher OK *1 Programming Console *2

*1.CX-Programmer version 9.1 or higher is required to use CJ2M CPU Units. *2.A Programming Console cannot be used with a CJ2M CPU Unit.

Device Type Setting


The unit version does not affect the setting made for the device type on the CX-Programmer. Select the device type as shown in the following table regardless of the unit version of the CPU Unit.
Series CJ Series CPU Unit group CJ2M CPU Units CPU Unit model CJ2M-CPU3@ CJ2M-CPU1@ CJ2M Device type setting on CX-Programmer Ver. 9.1 or higher

11

CJ2M-CPU3@/-CPU1@

External Interface
CJ2M-CPU3@ (CJ2M with Built-in EtherNet/IP)
A CJ2M-CPU3@ provides two communications ports for external interfaces: a peripheral (USB) port and an EtherNet/IP port. Serial ports can be added by mounting a Serial Communications Option Board (sold separately) in an option slot.
Battery Compartment LED Indicators DIP Switch (inside the battery compartment) Memory Card Indicators Indicates the Memory Card status (access and power supply). Peripheral (USB) Port Connected to Programming Devices, such as the CX-Programmer EtherNet/IP Port Connected to the information management system such as Host Computer Option board slot Add a serial option board (option)

Simple Backup/Memory Card Power Supply Switch Used to back up Memory Card data or turn OFF the power when removing the Memory Card. Also, press the Memory Card Power Supply Switch to perform an easy backup operation. Memory Card Connector Connects the Memory Card to the CPU Unit. Memory Card Eject Button Press the eject button to remove the Memory Card from the CPU Unit.

COMM

COMM

CP1W-CIF01 RS-232C Option Board

CP1W-CIF11/CIF12 RS-422A/485 Option Board

CJ2M-CPU1@
A CJ2M-CPU1@ provides two communications ports for external interfaces: a peripheral (USB) port and a serial port.
LED Indicator Battery Compartment Simple Backup/Memory Card Power Supply Switch Used to back uk Memory Card data or turn OFF the power when removing the Memory Card. Also, press the Memory Card Power Supply Switch to perform an easy backup operation. Memory Card Connector Connects the Memory Card to the CPU Unit. Memory Card Eject Button Press the eject button to remove the Memory Card from the CPU Unit. DIP Switch (inside the battery compartment) Memory Card Indicators Indicates the Memory Card status (access and power supply.) Peripheral (USB) Port Connected to Programming Device, such as the CX-Programmer Built-in Serial Port Connected to Programming Devices, Host Computers, general-purpose external sevice, Programmable Terminals, and other sevices.

12

CJ2M-CPU3@/-CPU1@
Peripheral (USB) Port
Item Baud Rate Transmission Distance Interface Protocol 12 Mbps max. 5 m max. USB 2.0-compliant B-type connector Peripheral Bus Specification

EtherNet/IP Port
Item Media Access Method Modulation Transmission Paths Baud Rate Transmission Media Transmission Distance Number of Cascade Connections Communications CSMA/CD Baseband Star 100 Mbps (100Base-TX) Shielded twisted-pair (STP) cable; Categories: 5, 5e 100 m (between hub and node) No restrictions if switching hub is used. CIP Communications (tag data links, Explicit Messages). FINS communications Specification

Built-in Serial Port (Only CJ2M-CPU1@)


Item Communications method Synchronization Baud rate Transmission distance Interface Protocol Half duplex Start-stop 0.3/0.6/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2 kbps * 15 m max. EIA RS-232C Host Link, NT Link, 1:N, No-protocol, or Peripheral Bus Specification

* Baud rates for the RS-232C are specified only up to 19.2 kbps. The CJ Series supports serial communications from 38.4 kbps to 115.2 kbps, but some computers cannot support these speeds. Lower the baud rate if necessary.
Pin No. 1 2 FG SD (TXD) RD (RXD) RS (RTS) CS (CTS) 5V DR (DSR) ER (DTR) SG (0 V) FG Signal Name Protection earth Send data Receive data Request to send Clear to send Power supply Data set ready Data terminal ready Signal ground Protection earth Output Input Output Input Input Output Direction

3 4 5 6 7 8 9 Connector hood

9 5

Note: Do not use the 5-V power from pin 6 of the RS-232C port for anything but CJ1W-CIF11 RS-422A Conversion Adapter, NT-AL001 RS-232C/ RS-422A Conversion Adapter and NV3W-M_20L Programmable Terminal. The external device or the CPU Unit may be damaged.

13

CJ2M-CPU3@/-CPU1@
Serial Option Board (Only CJ2M-CPU3@)
A Serial Option Board can be used with a CJ2M-CPU3@ CJ2M CPU Unit.
Model CP1W-CIF01 CP1W-CIF11 CP1W-CIF12 Port One RS-232C port One RS-422A/485 port (not isolated) One RS-422A/485 port (isolated) Maximum transmission distance 15 m 50 m 500 m Connection method Connector: D-sub, 9-pin female Terminal block: Using ferrules Terminal block: Using ferrules

CP1W-CIF01 RS-232C Option Board


Front Communications Status Indicator CPU Unit Connector
COMM

Back

RS-232 Connector

RS-232C Connector
Pin No. 1 2 3 FG SD (TXD) RD (RXD) RS (RTS) CS (CTS) 5V DR (DSR) ER (DTR) SG (0 V) FG Signal Name Protection earth Send data Receive data Request to send Clear to send Power supply Data set ready Data terminal ready Signal ground Protection earth Output Input Output Input Input Output Direction

4 5 6 7

8 9 Connector hood

Note: Do not use the 5-V power from pin 6 of the RS-232C port for anything but CJ1W-CIF11 RS-422A Conversion Adapter, NT-AL001 RS-232C/ RS-422A Conversion Adapter and NV3W-M_20L Programmable Terminal. The external device or the CPU Unit may be damaged. CP1W-CIF11/CIF12 RS-422A/485 Option Board
Front Communications Status Indicator CPU Unit Connector DIP Switch for Operation Settings Back

COMM
RDA- RDB+ SDA- SDB+ FG

RS-422A/485 Connector

RS-422A/485 Terminal Block

Tighten the terminal block screws to a torque of 0.28 Nm. RDARDB+ SDAFG SDB+

14

CJ2M-CPU3@/-CPU1@

Dimensions
CJ2M-CPU3@
2.7 76.2

(Unit: mm)

90

2.7

62

75 84.5

CJ2M-CPU1@
76.2

2.7

90

2.7 31

75 84.5

15

CJ2M-CPU3@/-CPU1@

Related Manuals
Cat. No. Model Manual Application Description Describes the following for CJ2 CPU Units: Overview and features Basic system configuration Part nomenclature and functions Mounting and setting procedure Remedies for errors Also refer to the Software Users Manual (W473). Describes the following for CJ2 CPU Units: CPU Unit operation Internal memory Programming Settings Functions built into the CPU Unit Also refer to the Hardware Users Manual (W472)

W472

CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@

CJ-series CJ2 CPU Unit Hardware Users Manual

Hardware specifications for CJ2 CPU Units

W473

CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@

CJ-series CJ2 CPU Unit Software Users Manual

Software specifications for CJ2 CPU Units

W474

CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU3@ CJ2M-CPU1@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1 CJ1G/H-CPU@@H CJ1G-CPU@@ CJ1M-CPU@@ NSJ@-@@@@(@)-@@@ CJ2H-CPU6@-EIP CJ2H-CPU6@ CJ2M-CPU@@ CS1G/H-CPU@@H CS1G/H-CPU@@-V1 CS1D-CPU@@H CS1D-CPU@@S CS1W-SCU@@-V1 CS1W-SCB@@-V1 CJ1H-CPU@@H-R CJ1G/H-CPU@@H CJ1G-CPU@@P CJ1M-CPU@@ CJ1G-CPU@@ CJ1W-SCU@@-V1 CP1H-X@@@@-@ CP1H-XA@@@@-@ CP1H-Y@@@@-@ NSJ@-@@@@(@)-@@@ CJ2H-CPU6@-EIP CJ2M-CPU3@ CS1W-EIP21 CJ1W-EIP21 CXONE-AL@@C-V@/ AL@@D-V@

CS/CJ/NSJ-series Instructions Reference Manual

Information on instructions

Describes each programming instruction in detail. Also refer to the Software Users Manual (W473) when you do programming.

W342

CS/CJ/CP/NSJ-series Communications Command Reference Manual

Information on communications for CS/CJ/CP-series CPU Units and NSJ-series Controllers

Describes C-mode commands and FINS commands Refer to this manual for a detailed description of commands for communications with the CPU Unit using C mode commands or FINS commands. Note: This manual describes the communications commands that are addressed to CPU Units. The communications path that is used is not relevant and can include any of the following: serial ports on CPU Units, communications ports on Serial Communications Units/Boards, and Communications Units. For communications commands addressed to Special I/O Units or CPU Bus Units, refer to the operation manual for the related Unit.

W465

CS and CJ Series EtherNet/IP Units CS1W-EIP21, CJ1WEIP21, CJ2H-CPU6@EIP, CJ2M-CPU3@ Operation Manual CX-One Setup Manual CX-Programmer Operation Manual CX-Programmer Operation Manual Functions Blocks/ Structured Text CX-Programmer Operation Manual SFC Programming

Information for EtherNet/IP function of CJ2M built-in Ethernet port

Describes EtherNet/IP port/units. A basic setting, a tag data link, FINS communication, and other function are described.

W463 W446

Installing software from the CX- Provides an overview of the CX-One FA Integrated Tool One Package and describes the installation procedure.

W447

Support Software for Windows computers CX-Programmer operating procedure

WS02-CXPC@-V@

Describes operating procedures for the CX-Programmer. Also refer to the Software Users Manual (W473) and Instructions Reference Manual (W474) when you do programming.

W469

W366

WS02-SIMC1-E

CS/CJ/CP/NSJ-series CX-Simulator Operation Manual

Operating procedures for CXSimulator Simulation Support Software for Windows computers Using simulation in the CXProgrammer with CXProgrammer version 6.1 or higher Network setup and monitoring

Describes the operating procedures for the CX-Simulator. When you do simulation, also refer to the CX-Programmer Operation Manual (W446), Software Users Manual (W473), and CS/CJ/NSJ series Instructions Reference Manual (W474).

W464

CXONE-AL@@C-V@/ CXONE-AL@@D-V@

CS/CJ/CP/NSJ-series CX-Integrator Network Configuration Software Operation Manual

Describes the operating procedures for the CX-Integrator.