Features
General
Performance:
— High flow capacity.
— Tight shut-off.
— Excellent flow control rangeability.
— Low weight.
— Streamline flow passages to improve
capacity.
Design Flexibility:
— Inherent Modified Equal Percentage trim,
with options for equal percentage and
linear from characterised positioner.
— Clamped guide and seat allows quick
change for modification/service.
— High interchangeability of trim components
and soft parts.
Design Integrity:
— Optimised using computer aided analysis.
— Designed to ASME B16.34
— High integrity precision cast components.
Quality Manufacturing:
— Rigorously tested to ensure specified
performance on site.
— Quality Assurance systems certified to ISO
9001
— NACE MR-01-75 certification.
Single Seated Globe Valve
Series 14 ABB Series14 -10/02
Design Standards:
ASME B16.34
IEC 534.3-1
2
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02
Design Cv Values
The design Cv values detailed below are defined as the flow of water (SG=1) through the valve at full lift in US gallons
per minute with a pressure drop of 1psi.
3
Single Seated Globe Valve
Series 14 ABB Series14 -10/02
Standard Duty
For standard duty applications there is the option of
Contoured trim (Figure 1) or
Cage Guided trim (Figures 2 and 3)
Characteristics Available:
Inherent Modified Equal Percentage (Equal Percentage
& Linear available with characterised positioner)
Plug Options: Figure 2. High Friction Cage Trim illustrated with Balanced
Unbalanced Contoured Trim. Plug
Direction of Flow:
Recommended flow under for both liquids and gas of
Contoured trims.
Flow over the plug for liquids & flow under for gases of
Cage Guided trims.
Severe Duty:
The High Friction (HF) trims are suitable for high Figure 3. High Friction HF trim illustrated with Solid Plug
4
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02
Trim Cv Calculation
A full set of procedures for calculating the Cv with various fluids is detailed in the Sizing and Selection Manual.
Please contact the nearest Sales Office for your copy.
Body Selection
The valve body must be capable of supporting the selected trim without producing excessive velocities. The following
tables can be used as a guide for determining the maximum recommended body velocities for both liquid and gas/
vapour applications.
Liquid Service
The velocities detailed in Table 3. below reflect the normal inlet and outlet maximum velocities recommended to
eliminate body erosion and prevent trim instability. Other factors may reduce the following figures further.
Refer to Sizing and Selection Manual for further details.
Table 3. Recommended maximum inlet and Outlet Velocities Liquid Service
Gas/Vapour Service
These velocities avoid problems of vibration and body erosion. Where noise levels are a consideration velocities
should be restricted to the relevant Mach numbers.
5
Single Seated Globe Valve
Series 14 ABB Series14 -10/02
Note: (STD) or (SPL) refer to the amount of seat/plug lapping carried out at final assembly.
6
Single Seated Globe Valve
Series 14 ABB Series 14 -10/02
Note:
1.Face to face dimensions comply with IEC 534.3-1
2.ABB Control Valves reserve the right to confirm
dimensions on certified drawings
*For other Valve/Actuator combinations, please consult
factory
Table 8. Valve Dimensions
7
Single Seated Globe Valve
Series 14 ABB Series14 -10/02