1. Introduction 1.1 Features ----------------------------------1 1.2 Specifications ----------------------------------1 1.3 Applications ----------------------------------1 2. Overview 2.1 Dimensions and mounting ----------------------------------2 2.2 LED Indicators ------------------------------------ 3 2.3 DIP Switch Settings ------------------------------------3 2.4 D-SUB Connector pin out -----------------------------------3 3. Configuration 3.1 Reset To Factory Default ----------------------------------4 3.2 DHCP Function ----------------------------------4 3.3 How to configure the IP address assigned to your AR-727CM device 5 3.3.1 Get IP address by using Net727i software ------------------------5 3.3.2 Get IP address by DHCP Server ----------------------------------8 3.3.3 Get IP address by Hyper-Terminal function of the Window ------10 2005/12/16

1. Introduction
The AR-727CM is an Ethernet to Serial Device Communication Controller. It transparently routes the data between Ethernet Port and Serial Port. The Device Server can be used in any application that need Ethernet and with a serial communication port already. 1.1 Features - Support Serial Port Freeze Function for High Security Use - Support Lock Remote IP Function - Provide TCP/IP Server Stack and DHCP function - One asynchronous serial ports allow full-duplex, 8-bit, none parity data transfers -

Serial port hardware handshaking with CTS and RTS selectable 10BASE-T NE2000 compatible Ethernet Controller Provide 256 Bytes Serial Buffer and 256 Bytes of TCP Buffer Auto Configuration of the IP and gateway addresses and subnet function Watchdog Timer included Remote Configuration Through Ethernet or Local Configuration via Serial Port DIP Switch Selectable for RS-485 or RS-232 Interface

1.2 Specifications -

Ethernet Serial Port Environment Power Suppiy (DC) Power Consumption Dimensions (mm) Accessories Power Software and Utility CDROM.

: : : : : : :

10Base-T NE2000 compatible 2400~57600 bps, None Parity, 8 data, 1 stop bit -20C to +75C 9.0 ~ 24.0 VDC 1.5W (max) 100 X 60 X 23 One DB9 Male Cable for RS-485/RS-232 and

: Net727i Setup Program in Floppy Disk or

1.3 Applications Access Controller, Time Recorder, Industry Controller, etc.

Serial Port DC-IN

2. Overview

ACT

Power Serial RX Serial TX BUSY Link

SOYAL
AR-727CM
1
ON ON OFF ON OFF ON ON OFF ON OFF ON OFF

DIP-SW
Setup Mode RS-485 RUN Mode RS-485 OFF OFF DHCP Enable DHCP Disable RS-232 RS-232

2.1 Dimensions and mounting

How to install:
2 3 4
DB9 RS-485
B(-) Tx ( Output) 2 3 5 6 4 Rx ( Input ) GND Power DC Power DC 9 A(+) 1

RS-232

DIP-SW

RESET Ethernet Port

Screw length must no longer than 6mm.

Remove Jumper if powered by External Adapter. Close Jumper if powered through DB9 (4,6).

2.2 LED Indicators AR-727CMs top panel contains six LED indicators, as described in the following table. LED Name POWER Link ACT BUSY Serial RX Serial TX LED Color Green Off Yellow Off Green Off Red Off Green Off Red Off 2.3 DIP Switch Settings DIP Switch Serial Setup Mode RS-232 Two Wire RS-485 1 ON 2 ON OFF 3 OFF ON OFF ON ON OFF 4 LED Function Power is on. Power is off, or power error condition exits. Media is connected. Media is not connected. 10 Mbps Ethernet connection. Ethernet cable is disconnected, or has a short. Configuration Setup. No. Serial data is being received. Serial data is not being received. Serial data is being transmitted. Serial data is not being transmitted.

RS-232 OFF ON Normal Run Mode and Two wire RS-485 OFF Networking Setup DHCP Enable (Auto IP Address Configuration) DHCP Disable (Auto IP Address Configuration) 2.4 D-SUB Connector pin out Function Two Wire RS-485 DATA (A +) DATA (B -) Data Transmit Data Receive RS-232 Signal Ground Request to send (RTS) Clear to Send (CTS) Power Input Power Source : V+ Power Ground : VPin Wire Color 1 9 2 3 5 8 7 6 4 Blue Green White Yellow Brown Gray Purple Red Black

Type Bi-direction Bi-direction Output Input Output Input Depend on JP1 Setting

AR-727CM has two way of power supply, one from power jack and one from DB9. In general usually, The Serial Device has DC power already, so AR-727CM can share the power with Serial Device. The DB9 pin-4 connect to Power Ground (V-), pin-6 Connect to Power Source (V+). If you power AR-727CM from Adapter, remove the jumper from JP1.

3. Configuration
3.1 Reset To Factory Default Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-727CM will restore to Factory Default value. DIPswitch is OFF, OFF, OFF, OFF position. IP Address : 192.168.001.127 Gateway IP Subnet Mask Serial Port TCP Port Password
DIP Switch position OFF, OFF, OFF, OFF

: 192.168.001.254 : 255.255.255.000 : 9600,N,8,1 : 1621 : none

3.2 DHCP Function AR-727CM support Auto Configuration of the IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. Switch DIP SW-4 to ON position then power cycle the Device. In begging state the ACT LED will flashing, After IP has got ACT LED will off and auto save the new IP address to EEPROM, Switch DIP SW-4 to OFF position and move DIP SW-1 to ON position then you can get the new IP from Serial port via Hyper terminal.

3.3 How to configure the IP address assigned to your AR-727CM device? 3.3.1 Get IP address by using Net727i software Usually, the network of some company dont built-in the DHCP Server. Therefore, we can use the following method to get default IP address and modify it. The steps as follows: Step 1: Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-727CM will restore to Factory Default value. Step 2: Open explorer, click My Network Places and press right key to open Properties.

Step 3: Click Local Area Connection and press right key to open Properties. Then double click Internet Protocol (TCP/IP) to open Properties.

Step 4: Click Use the following IP address and enter IP address 192.168.001.64, Subnet mask 255.255.255.0

Step 5: Click ok to exit. Step 6: Install Net727i.exe into your PC and run Net727i.exe (Start Programs soyal software Net727i )

Step 7: Click Get to get default Local IP Address, Gateway, Netmask and TCP Port. Step 8: Change new address and parameters then click write. Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode. Remark: (1) How to know PCs IP Address? (Win98) Start execute enter winipcfg. (2) How to know PCs IP Address? (Win2000) Start Programs Accessories Command Prompt (3) Please see detailed parameter in next page: Setting Value Local IP Address 192.168.001 .127 Local Gateway IP 192.168.001 Address .254 Local Subnet 255.255.255 Mask .000 TCP Port 1621

C:\> ipconfig

Notes Defines own IP Address of the AR-727CM

Necessity Required Required Required Required

Defines the IP Address of the default gateway Defines the IP Address range for the local network segment The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports. MAC Address 00.E0.4C.00 The MAC (Media Access Control) address is .00.50 a unique identifier set at the factory. Force Transmit 5 Forces AR-727CM devices TCP/IP protocol time software to try to pack serial data received during the specified time into the same data frame. Force Transmit 32 Defines the amount of data in the serial, Bytes Ethernet buffer at which the break condition will be generated and the contents of buffer will be sent out via the Ethernet port. Lock Remote IP Allows contact with only the specified remote Address IP address. To avoid the hacker use this IP to intercept Lock Serial Port data when Remote IP Address doesnt (Free Run or receive data. Freeze Over) Setup Password none Console password Serial Port Speed 9600 Changes current baud rate of the AR-727CMs serial port (from 2400bps to 57600bps). 60 This device automatically closes TCP TCP Auto connection if there is no TCP activity for the Disconnect Time given time. (Second) An exchange of signal over specific wires Serial Port which each device indicates its readiness to Hardware send or receive data. Handshaking (RTS/CTS) DHCP Selecting the enable option allows DHCP to automatically assign the AR-727CMs IP address.
7

Optional

Optional

Optional Optional

Optional Required

Optional

Optional

Optional

3.3.2 Get IP address by DHCP Server AR-727CM support Auto Configuration of the IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. The steps as follows: Step 1: Switch DIP Switch position to OFF, OFF, OFF, ON. Step 2: Power cycle the device Step 3: In begging state the ACT LED will flashing, after IP has got ACT LED will off and auto save the new IP address to EEPROM. Step 4: Switch DIP SW-4 to OFF position and move DIP SW-1 and SW-2 to ON position Step 5:To modify parameter on the AR-727CM through the Hyper-Terminal function of the Window. (Start Programs Accessories Communication Step 6: Click Hyper-Terminal. Step 7: key-in any temporary name. Shown as follows: It is not important matter. Hyper Terminal)

Step 8: Choose which COM port and click OK to exit.

Step 9: Set Port Settings to 9600, 8, None, 1, None and click OK to save.

Step 10: AR-727CM already gets IP address now shown as follows: Note that save it after set all parameters.

Step 11: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.

3.3.3 Get IP address by Hyper-Terminal function of the Window Step 1: To get Default IP address on the AR-727CM through the Hyper-Terminal function of the Window. (Start Terminal) Programs Accessories Communication Hyper

Step 2: Click Hyper-Terminal. Shown as follows:

Step 3: key-in any temporary name. It is not important matter.

Step 4: Choose which COM port and click OK to exit.

Step 5: Set Port Settings to 9600, 8, None, 1, None and click OK to save.

10

Step 6: AR-727CM already gets IP address now shown as follows:

Step 7: Please refer above parameters.

item and enter item on the

so that set all

Step 8: Note that enter item 6 on the set parameter.

to save parameter after finishing to

Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.