INSTALLATION INSTRUCTIONS
Elite Series CB29M and CB30M Units
MULTIPOSITION AIR HANDLER
505,339M 05/08 Supersedes 04/08
Litho U.S.A.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer or service agency.
CAUTION
Physical contact with metal edges and corners while applying excessive force or rapid motion can result in personal injury. Be aware of, and use caution when working near these areas during installation or while servicing this equipment.
Table of Contents
CB29M Upflow/Downflow Unit Dimensions . . . . . . CB29M Horizontal LH/RH Unit Dimensions . . . . . . . CB30M Upflow/Downflow Unit Dimensions . . . . . . CB30M Horizontal LH/RH Unit Dimensions . . . . . . . General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . Shipping and Packing List . . . . . . . . . . . . . . . . . . . . . . Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brazing Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Condensate Drain . . . . . . . . . . . . . . . . . Inspecting and Replacing Filters . . . . . . . . . . . . . . . . . Sealing the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjusting the Blower Speed . . . . . . . . . . . . . . . . . . . . Making Electrical Connections . . . . . . . . . . . . . . . . . . Repairing or Replacing Cabinet Insulation . . . . . . . . . 2 3 4 5 6 6 6 6 9 10 10 10 11 17 22
IMPORTANT
The Clean Air Act of 1990 bans the intentional venting of refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992. Approved methods of recovery, recycling or reclaiming must be followed. Fines and/or incarceration may be levied for noncompliance.
IMPORTANT
This unit must be matched with an indoor coil as specified in Lennox Engineering Handbook. Coils previously charged with HCFC22 must be flushed.
TOP CAP SHIPPING BRACKET (REPLACE SCREWS IN TOP CAP AFTER REMOVAL)
D
REFRIGERANT LINE CAPS [SEE BRAZING CONNECTIONS ON PAGE 9]
HORIZONTAL DRAIN PAN (SEE UPFLOW APPLICATIONS ON PAGE 6 AND DOWNFLOW APPLICATIONS ON PAGE 8 )
*2P0508*
05/08
Page 1
*P505339M*
505,339M
5/8 (16)
D
11-1/16 (281)
3/4 (19)
F E
RETURN AIR OPENING
5-3/8 (137) LINE VOLTAGE INLETS (TOP AND LEFT SIDE) LOW VOLTAGE INLETS (TOP AND RIGHT SIDE)
2-3/4 (70)
3-1/2 (89)
Top View B
5/8 (16)
1-3/4 (44)
1 (25)
Top View C C B
FILTER ACCESS
COIL
LIQUID LINE
A
SUCTION LINE COIL OPTIONAL ELECTRIC HEAT (FIELD INSTALLED) LOW VOLTAGE (RIGHT SIDE) LINE VOLTAGE (LEFT SIDE) RETURN AIR SUPPLY AIR 11-1/16 (281) 5/8 (16) 5/8 (16) 5/8 (16) SUPPLY AIR BLOWER AIR FLOW
F
5/8 (16)
E
1 (25)
D Front View
5/8 (16)
Front View
Side View
Side View
Upflow Position
Model No. Dimension A B C D E F CB29M-21/26 and CB29M-31 inch mm 45-1/4 1149 16-1/4 413 20-5/8 524 14-3/4 375 19 483 15 351
Downflow Position
(Kit number 83M57 (LB909844A) required to convert unit to downflow applications.)
CB29M-41 and CB29M-46 inch mm 49-1/4 1251 21-1/4 540 20-5/8 524 19-3/4 502 19 483 20 508
Page 2
505339M 05/08
CONDENSATE DRAINS (2) (UPFLOW AND DOWN FLOW) CONDENSATE DRAINS (2) (HORIZONTAL)
COIL
BLOWER
LIQUID LINE
SUCTION LINE
Top View
PIPING PLATE DETAIL 5-3/4 (46) 5/8 (16) 1-3/4 (44) 1-1/2 (38) 5/8 (16) 11-1/16 3/4 (281) (19) LINE VOLTAGE INLETS (TOP AND RIGHT SIDE) AIR FLOW 3/4 (19) SUPPLY AIR OPENING LOW VOLTAGE INLETS (BOTTOM AND RIGHT SIDE) FILTER ACCESS
5/8 (16)
E F
RETURN AIR OPENING
1 (25)
3/4 (19)
Front View
End View
End View
5/8 (16)
BLOWER
COIL 1-1/8 (29) PIPING PLATE DETAIL SUCTION LINE LIQUID LINE 2 (51) 5/8 (16) 5-3/8 (137)
OPTIONAL ELECTRIC HEAT (FIELD INSTALLED) 3/4 (19) 11-1/16 (281) 3/4 (19) LOW VOLTAGE INLETS (TOP AND LEFT SIDE) 5/8 (16)
FILTER
Top View A
SUCTION LINE
LIQUID LINE
AIR FLOW
1 (25)
E F
RETURN AIR OPENING
5/8 (16)
3/4 (19)
End View
1-3/4 (44)
Front View
5-3/4 (146)
End View
5/8 (16)
Page 3
CB29M/CB30M SERIES
D
11-1/16 (281)
3/4 (19)
CONDENSATE DRAINS (2) (HORIZONTAL) 2 (51) LIQUID LINE CONDENSATE DRAINS (2) (UPFLOW AND DOWNFLOW) 2-3/4 (70) 3-1/2 (89) 1-3/4 (44)
5/8 (16)
5/8 (16)
F E
RETURN AIR OPENING
5-3/8 (137) LINE VOLTAGE INLETS (TOP AND LEFT SIDE) LOW VOLTAGE INLETS (TOP AND RIGHT SIDE) 5/8 (16)
1 (25)
Top View B
Top View B
FILTER ACCESS
H
COIL
G
AIR FLOW OPTIONAL ELECTRIC HEAT (FIELD INSTALLED)
BLOWER
A
SUCTION LINE COIL
LIQUID LINE OPTIONAL ELECTRIC HEAT (FIELD INSTALLED) LOW VOLTAGE (RIGHT SIDE) LINE VOLTAGE (LEFT SIDE)
A
AIR FLOW BLOWER
RETURN AIR
RETURN AIR
F
5/8 (16)
E
1 (25)
SUPPLY AIR 11-1/16 (281) 5/8 (16) 5/8 (16) 5/8 (16)
SUPPLY AIR
D Front View
5/8 (16)
Front View
Side View
Side View
Upflow Position
Model No. Dimension A B C D E F G H CB30M-21/26 inch 45-1/4 16-1/4 20-5/8 14-3/4 19 15 24-5/8 20-5/8 mm 1149 413 524 375 483 351 625 524 CB30M-31 inch 49-1/4 21-1/4 20-5/8 19-3/4 19 20 24-5/8 24-5/8 mm 1251 540 524 502 483 508 625 625
Downflow Position
(Kit number 83M57 (LB909844A) required to convert unit to downflow applications.)
CB30M-41 inch 51 21-1/4 22-5/8 19-3/4 21 20 26-3/8 24-5/8 mm 1295 540 575 502 533 508 670 625
CB30M-46 inch 52-1/2 21-1/4 22-5/8 19-3/4 21 20 27-7/8 24-5/8 mm 1334 540 575 502 533 508 708 625
CB30M-51 and CB30M-65 inch 58-1/2 21-1/4 24-5/8 19-3/4 23 20 27-7/8 30-5/8 mm 1486 540 625 502 584 508 708 778
Page 4
505339M 05/08
CONDENSATE DRAINS (2) (UPFLOW AND DOWN FLOW) CONDENSATE DRAINS (2) (HORIZONTAL)
COIL
C
FOR DIMENSIONS A THROUGH H, SEE CHART ON PAGE 4.
LIQUID LINE
SUCTION LINE
Top View
1-3/4 (44)
1-1/2 (38)
A H G
5/8 (16)
E F
RETURN AIR OPENING
1 (25)
AIR FLOW
B
LOW VOLTAGE INLETS (BOTTOM AND RIGHT SIDE)
3/4 (19)
FILTER ACCESS
Front View
End View
End View
5/8 (16)
BLOWER
OPTIONAL ELECTRIC HEAT (FIELD INSTALLED) 3/4 LOW VOLTAGE INLETS (TOP (19) 11-1/16 (281) AND LEFT SIDE) 3/4 (19)
FILTER
Top View A
5/8 (16)
AIR FLOW
1 (25)
E F
RETURN AIR OPENING
5/8 (16)
3/4 (19) LINE VOLTAGE INLETS (BOTTOM AND LEFT SIDE) End View
1-3/4 (44)
Front View
5-3/4 (146)
End View
5/8 (16)
Page 5
CB29M/CB30M SERIES
WARNING
Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.) Fiberglass wool may also cause respiratory, skin, and eye irritation. To reduce exposure to this substance or for further information, consult material safety data sheets available from address shown below, or contact your supervisor. Lennox Industries Inc. P.O. Box 799900 Dallas, TX 753799900
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer or service agency. The CB29M and CB30M units, designed for multipositional installations, are completely assembled at the factory and shipped ready for upflow or horizontal righthand discharge installation. For downflow or horizontal lefthand discharge, some field modification is required.
IMPORTANT
Kit number 83M57 (LB109844A) must be installed for downflow application. DISASSEMBLE AND REASSEMBLE AIR HANDLER UNITS The air handler units consists of two factory-assembled sections. It may be necessary to disassemble the sections when positioning the unit for installation. To disassemble: Step 1. Remove access panels. Step 2. Remove both blower and coil assemblies. This will lighten the cabinet for lifting. Step 3. Remove one screw from the left and right posts inside the unit. Remove one screw from each side on the back of the unit. Unit sections will now separate. To reassemble: Step 1. Align cabinet sections together. Step 2. Reinstall screws. Step 3. Replace blower and coil assemblies. Step 4. Replace access panel. UPFLOW APPLICATION Use the following procedures to configure the unit for upflow operations: Step 1. Remove access panels. Step 2. Remove corrugated padding from the space between the blower and coil assemblies. Step 3. The horizontal drain pan must be removed when the coil blower is installed in the upflow position. Removing horizontal drain pain will allow proper airflow and increase efficiency. Step 4. Place unit in desired location. Make sure that unit is level. Connect return and supply air plenums as required using sheet metal screws.
General Information
The Lennox Elite Series CB29M and CB30M air handler units are designed for installation with a matched remote outdoor unit and optional fieldinstalled electric heat. The air handler coil units are for indoor installation only. These instructions are intended as a general guide and do not supersede local or national codes in any way. Consult authorities having jurisdiction before installation. Check equipment for shipping damage; if found, immediately report damage to the last carrier.
Requirements
In addition to conforming to manufacturers installation instructions and local municipal building codes, installation of Lennox air handler units (with or without optional electric heat), MUST conform with the following National Fire Protection Association (NFPA) standards:
S S
NFPA No. 90A Standard for Installation of Air Conditioning and Ventilation Systems NFPA No. 90B Standard for Installation of Residence Type Warm Air Heating and Air Conditioning Systems
This unit is approved for installation clearance to combustible material as stated on the unit rating plate. Accessibility and service clearances must take precedence over combustible material clearances.
Page 6
505339M 05/08
Step 5.
Install units that have no return air plenum on a mounting stand at least 14" from the floor for proper air return. Lennox offers an optional upflow unit stand as listed in table 1. Kit Number
45K31 45K32
FRONT VIEW
END VIEW
CAUTION
HORIZONTAL DRAIN PAN (MUST BE REMOVED)
When removing the coil, there is possible danger of equipment damage and personal injury. Be careful when removing the coil assembly from a unit installed in right or lefthand applications. The coil may tip into the drain pan once it is clear of the cabinet. Support the coil when removing it. HORIZONTAL LEFTHAND DISCHARGE APPLICATION NOTE For horizontal applications, an auxiliary drain pan is recommended. Refer to local codes. Use the following procedures to configure the unit for horizontal lefthand discharge operations: Step 1. Remove the access panels and the corrugated padding from the space between the blower and coil assembly before operation. Step 2. Remove the coil assembly from unit, and the remove the horizontal drain pan as illustrated in figure 4, detail A on page 8. Step 3. Remove drain plugs from back drain holes on horizontal drain pan, and reinstall them on front holes. Step 4. Rotate drain pan 180 front to back and install it on the opposite side of coil. Step 5. Remove screws from top cap, and then remove horizontal drip shield screw located in the center of the back coil end seal as illustrated in figure 4, detail B and C on page 8. Step 6. Rotate horizontal drip shield 180 front to back. Step 7. Remove plastic plug from left hole on coil front end seal and reinstall plug in back hole. Reinstall horizontal drip shield screw in front coil end seal. Drip shield should drain downward into horizontal drain pan inside coil. Step 8. Rotate top cap 180 front to back and align with unused screw holes. Holes must align with front and back coil end plates. Note that top cap has a 45 bend on one side and 90 bend on the other. The 90 bend must be on the same side as the horizontal drain pan as illustrated in figure 4.
Figure 1. Upflow Configuration HORIZONTAL RIGHTHAND DISCHARGE APPLICATION Use the following procedures to configure the unit for horizontal righthand discharge operations: NOTE For horizontal applications, an auxiliary drain pan is recommended. Refer to local codes. Step 1. Remove access panels. Remove corrugated padding from the space between the blower and coil assembly. Step 2. No further adjustment is necessary. Set unit so that it is sloped 1/4 inch toward the drain pan end of the unit. If the unit is to be suspended, it must be supported along the entire length of the cabinet as illustrated in figure 3. If using a chain or strap, attach a piece of angle iron or sheet metal to the unit (either above or below the unit), so that the full length of the cabinet is supported. Use securing screws which are no longer than 1/2 inch to avoid damaging the coil or filter. Use sheet metal screws to connect the return and supply air plenums.
HORIZONTAL DRIP SHIELD UPFLOW/ DOWNFLOW DRAIN PAN HORIZONTAL DRAIN PAN
Step 3.
NO ADJUSTMENT IS NECESSARY
Page 7
CB29M/CB30M SERIES
COIL ASSEMBLY
NEW PLUG LOCATION TOP CAP ROTATED TO CORRECT POSITION TOP CAP SCREWS DETAIL B (TOP CAP)
From the upflow position, flip cabinet 90 to the left and set into place. Replace coil assembly and secure coil in place by bending down tab on cabinet support rail as illustrated in figure 5. NOTE For horizontal applications in high humidity areas, seal around the exiting drain pipe, liquid line and suction line to prevent infiltration of humid air. Step 10. Knock out drain seal plate from access door. Secure plate to cabinet front flange with screw provided. Step 11. Flip access door and replace it on the unit. Step 12. Set unit so that it is sloped 1/4 inch toward the drain pan end of the unit. Connect return and supply air plenums as required using sheet metal screws. Step 13. If the unit is to be suspended, it must be supported along the entire length of the cabinet as illustrated in figure figure 3 on page 7. If using a chain or strap, attach a piece of angle iron or sheet metal to the unit (either above or below the unit), so that the full length of the cabinet is supported. Use securing screws which are no longer than 1/2 inch to avoid damaging the coil or filter. Use sheet metal screws to connect the return and supply air plenums. DOWNFLOW APPLICATION Use the following procedures to configure the unit for downflow operations:
TOP CAP
WARNING
If electric heat section with circuit breakers (ECB29) are applied to downflow CB29M or CB30M unit, circuit breakers must be rotated 180_ to the UP position. See ECB29 installation instructions for more details. NOTE If downflow application is required, separately order kit number 83M57 and install per kits instructions. Also, use metal or class I supply and return air plenums. Step 1. Cut an appropriately-sized opening for the base using dimensions listed in figure 7. NOTE On combustible flooring in downflow installations, a downflow combustible floor base kit must be used as illustrated in figure 6 on page 9. Step 2. After opening has been cut, set the base into opening. Connect outlet air plenum to the base. Set the unit on the downflow combustible base so flanges of the unit drop into the base opening and seal against the insulation strips. The unit is now locked in place. Install return air plenum and secure with sheet metal screws.
Figure 4. LeftHand Discharge Modifications NOTE Use extreme care when reinstalling screws into coil end plate engaging holes. Misaligned screws may damage coil.
Securing Tab on Cabinet Support Rail Horizontal Drip Shield
Step 3.
Step 4.
Page 8
505339M 05/08
WARNING
Danger of explosion! Can cause equipment damage, injury, or death. When using a high pressure gas such as dry nitrogen to pressurize a refrigeration or air conditioning system, use a regulator that can control the pressure down to 1 or 2 psig (6.9 to 13.8 kPa).
Figure 6. Combustible Flooring Additive Base If the homeowner reports water dripping from supply air diffusers, check the shields and tape. Make sure the tape is completely attached to the edges of the drip shield, and that the drip shield is wedged firmly in place.
AIR HANDLER UNIT 11-3/8 (289) 1-5/8 (41) 1-5/8 (41) 15 (381) CB29M21/26 and 31 CB30M21/26 20 (508) CB29M41 to 65 CB30M31 to 65 181/4 (464) CB29M21/26 and 31 CB30M21/26 231/4 (591) CB29M41 to 65 CB30M31 to 65
inches (mm)
1-5/8 (41)
TOP VIEW
5/8 (16) 22-1/8 (562) 13-3/8 (340) OPENING 2 (51)
Figure 8. Brazing Connections NOTE CB29M/CB30M series evaporators use nitrogen or dry air as a holding charge. If there is no pressure when the rubber plugs are removed, check the coil or line set for leaks before installing. After installation, pull a vacuum on the line set and coil before releasing the unit charge into the system. NOTE: See outdoor unit instructions on how to flow nitrogen through line sets. Step 1. Step 2. Step 3. Remove access panel. Remove the refrigerant line caps from the refrigerant lines. Use a wet rag to protect TXV sensing bulb (or remove it) when brazing suction line connections. Place a wet rag against piping plate and around the suction line connection. The wet rag must be in place to guard against damage to the paint. With the wet rag in place, position field provided elbow fitting to air handlers suction line and line set. Start nitrogen flow before brazing. After the procedure is completed then remove the wet rag. Place wet rag against piping plate and around the liquid line connection. Position liquid line elbow to air handlers suction line and to line set. Start nitrogen flow and begin brazing both connections and after procedure is completed then remove both wet rags.
SIDE VIEW
Brazing Connections
All CB29M/CB30M coils are equipped with a factoryinstalled, internally mounted expansion valve. Use Lennox L15 (sweat) series line sets as listed in table 2, or use fieldfabricated refrigerant lines. L10 (flare) line sets may be used by cutting off flare nut. Refer to the piping section of the Lennox Unit Information Service Manual for proper size, type and application of fieldfabricated lines.
Step 4.
Step 5.
IMPORTANT
To prevent the build up of high levels of nitrogen when purging, be sure it is done in a well ventilated area. Purge low pressure nitrogen (1 to 2 psig) through the refrigerant piping during brazing. This will help to prevent oxidation and the introduction of moisture into a system.
Step 6. Step 7.
Page 9
CB29M/CB30M SERIES
Step 8.
Step 9.
Units 21 and 26 31 and 41 46 and 51
Refer to instructions provided with outdoor unit for leak testing, evacuating and charging procedures. Install access panel. Table 2. Refrigerant Line Sets
Liquid Line No. 3/8 in (8 mm) 3/8 in (10 mm) 3/8 in (10 mm) 3/8 in (10 mm) Vapor/ Suction Line 5/8 in (16 mm) 3/4 in. (19 mm 7/8 in. (22 mm) 11/8 in. (29 mm) L10 Line Sets L1026 20 ft. 50 ft. (6 m 15 m) L1041 20 ft. 50 ft. (6 m 15 m) L1065 30 ft. 50 ft. (9 m 15 m) FIELD FABRICATED L15 Line Sets L1526 20 ft. 50 ft. (6 m 15 m) L1541 20 ft. 50 ft. (6 m 15 m) L1565 30 ft. 50 ft. (9 m 15 m) FIELD FABRICATED
S S S
S S S S
65
Drain piping should not be smaller than the drain connections at drain pan. A trap must be installed in the main drain line. The trap must be deep enough to offset the difference in static pressure between drain pan and atmosphere. Generally, two inches is satisfactory for medium static applications. Horizontal runs must be sloped 1 inch per 10 feet of drain line to offset friction. An open vent in drain line will sometimes be required due to line length, friction and static pressure. Drain construction and routing should facilitate future cleaning and must not interfere with filter access. Auxiliary drain should run to an area where homeowner will notice any drainage. The auxillary drain line does not required venting or a trap. Refer to local codes.
IMPORTANT
Filter access panel must be in place during unit operation. Excessive warm air entering the unit may result in water blowoff problems. Each unit includes a factoryinstalled filter. Note that filter access door fits over access panel. Air leakage will occur if access panel is placed over filter door. Filters should be inspected monthly and must be cleaned or replaced when dirty to assure proper furnace operation. Reusable filters supplied with some units can be washed with water and mild detergent. Some units are equipped with standard throwaway type filters which should be replaced when dirty. Step 1. Step 2. Loosen the thumbscrews holding the filter panel in place. Insert new filter and replace panel. Table 3. Filter Dimensions
Unit Model Number Filter Size Inches (mm)
15 x 20 (381 x 508) 20 x 20 (508 x 508) 20 x 22 (508 x 559) 20 x 24 (508 x 610)
DRAIN PAN
TRAP MUST BE DEEP ENOUGH TO OFFSET MAXIMUM STATIC DIFFERENCE (GENERALLY, 2 INCHES [51MM]). TRAP (49P66) DRAIN LINE SHOULD SLOPE A MINIMUM 1 INCH PER 10 FEET (25 MM PER 3 M)
TO APPROVED DRAIN
Figure 9. Typical Condensate Drain It is recommended that the auxiliary drain be connected to a drain line for all units. If auxiliary drain is not connected, it must be plugged with provided cap. For downflow units, the auxiliary drain MUST be connected and routed to a drain. See figure 10 for auxiliary and main drain locations.
LEFTHAND DISCHARGE UPFLOW OR DOWNFLOW RIGHTHAND DISCHARGE
Figure 10. Auxiliary and Main Drain Locations The following practices are recommended to ensure condensate removal as illustrated in figures 9 and 10:
Page 10
505339M 05/08
Make sure the liquid line and suction line entry points are sealed with either the provided flexible elastomeric thermal insulation, or field provided material (e.g. Armaflex, Permagum or equivalent). Any of the previously mention materials may be used to seal around the main and auxiliary drains, and around open areas of electrical inlets.
HARNESS CONNECTOR
Watts 375 370 365 355 350 345 335 320 305 290 265 255
Watts 450 445 440 430 425 415 405 390 370 350 330 315
Page 11
CB29M/CB30M SERIES
Watts 655 640 630 615 600 585 570 540 510 480 455 425
Watts 665 650 640 630 615 600 585 555 520 480 430
Watts 730 720 710 700 685 675 660 635 605 575 545 480
Page 12
505339M 05/08
Watts 1005 995 980 970 955 940 930 900 875 845 820 800
cfm
Watts 965 950 935 920 910 895 885 860 835 805 780 755 745
.00 0 1695 800 680 1900 895 805 2140 1010 .05 10 1675 790 670 1880 885 795 2110 995 .10 25 1655 780 665 1855 875 780 2080 980 .15 35 1640 775 655 1830 865 770 2050 970 .20 50 1620 765 650 1805 850 755 2025 955 .25 60 1595 750 640 1775 840 740 1995 940 .30 75 1570 740 630 1750 825 730 1965 925 .40 100 1525 720 610 1700 805 710 1905 900 .50 125 1475 695 595 1640 775 685 1845 870 .60 150 1420 670 575 1585 750 665 1770 835 .70 175 1355 640 555 1515 715 640 1700 800 .80 200 1290 610 535 1450 685 620 1625 765 .85 210 1255 590 525 1405 665 610 1595 750 NOTE All air data is measured external to unit with air filter in place. Electric heaters have no appreciable air resistance.
Page 13
CB29M/CB30M SERIES
Watts 1145 1135 1120 1105 1095 1085 1075 1050 1025 1000 975 955 925
Watts 365 360 355 345 340 335 325 310 295 280 265 255
Watts 385 380 375 370 360 350 335 305 275 240
Page 14
505339M 05/08
Watts 505 495 480 470 455 440 430 400 375 345 320 305
Watts 505 495 480 470 455 440 430 400 375 345 320 305
Watts 565 555 540 530 520 505 495 465 440 415 385 370
Page 15
CB29M/CB30M SERIES
Watts 590 585 580 570 565 550 540 515 485 450 415 400
Watts 610 610 590 585 575 560 545 505 470 425 385 340
Watts 780 770 765 750 740 730 715 685 655 625 590 560 545
Page 16
505339M 05/08
Watts 795 780 765 755 740 725 710 680 650 615 585 550 535
CAUTION
USE COPPER CONDUCTORS ONLY. Wiring must conform to the current National Electric Code ANSI/NFPA No. 70, or Canadian Electric Code Part I, CSA Standard C22.1, and local building codes. Refer to following wiring diagrams. See unit nameplate for minimum circuit ampacity and maximum overcurrent protection size. Select the proper supply circuit conductors in accordance with Tables 31016 and 31017 in the National Electric Code, ANSI/NFPA No. 70 or Tables 1 through 4 in the Canadian Electric Code, Part I, CSA Standard C22.1.
This unit is provided with knockouts for conduit. Reducer washers are provided, in bag assembly to allow use of smaller conduit. Use provided caps to seal holes not used. Refer to figure 12 for unit schematic wiring diagram. Refer to figures 14 and 15 for typical field wiring. Separate openings have been provided for 24V low voltage and line voltage. Refer to the dimension illustration for specific location.
WARNING
Run 24V Class II wiring only through specified low voltage opening. Run line voltage wiring only through specified high voltage opening. Do not combine voltage in one opening.
Page 17
CB29M/CB30M SERIES
Figure 12. CB29 and CB30 Typical Wiring Diagram Single Phase
Page 18
505339M 05/08
Figure 13
Page 19
CB29M/CB30M SERIES
(Black) (Orange)
CIRCUIT 1
6 3
FUSE
Figure 14
Page 20
505339M 05/08
6 3
TO EXTERNAL LOAD 24VAC AT .50 AMP MAXIMUM FACTORY INSTALLED JUMPERS Y2 USED ONLY WHEN TWO SPEED COMPRESSOR IS USED (HP21).
USING SERVICE LIGHT OPTION (S54) WITH SOME ELECTRONIC THERMOSTATS MAY REQUIRE MOVING S54 COMMON WIRE TO Y1 IN HEAT PUMP UNIT. COMMON USED ONLY ON SOME THERMOSTATS. AMBIENT COMPENSATING THERMISTOR CONNECTION USED ONLY ON SOME THERMOSTATS.
FUSE E
2 5
C W1 G
O Y1
Y2
3
REVERSING VALVE SERVICE LIGHT ELECTRIC HEAT COMPRESSOR THERMISTOR W1 O Y1 R POWER L T 2ND STAGE COMPRESSOR Y2 COMMON
6 3 9
W1
O Y1
T Y2
S23
LINE VOLTAGE FIELD INSTALLED CLASS 2 VOLTAGE FIELD INSTALLED NEC/CEC NOTE ALL REMAINING WIRES ARE FACTORY INSTALLED THERMOSTAT HEAT ANTICIPATION SETTING 0.4 AMP ELECTRIC HEAT FACTORY INSTALLED JUMPERS WHEN OUTDOOR THERMOSTAT IS USED, CONNECT LEADS TO TERMINALS R" AND W2" AND REMOVE JUMPER BETWEEN TERMINALS R AND W2." EMERGENCY HEAT RELAY (USED ONLY IF OUTDOOR TSTAT IS USED) FIELD PROVIDED AND INSTALLED NEW INDOOR UNIT. 24VAC 5VA MAX NEC/CEC CLASS 2 C COMMON W1 ELECTRIC HEAT O REVERSING VALVE Y1 COMPRESSOR R POWER L SERVICE LIGHT T THERMISTOR Y2 2ND STAGE COMPRESSOR
USING SERVICE LIGHT OPTION (S54) WITH SOME ELECTRONIC THERMOSTATS MAY REQUIRE MOVING S54 COMMON WIRE TO Y1 IN HEAT PUMP UNIT. COMMON USED ONLY ON SOME THERMOSTATS. Y2 USED ONLY WHEN TWO-SPEED COMPRESSOR IS USED (HP21) AMBIENT COMPENSATING THERMISTOR CONNECTION USED ONLY ON SOME THERMOSTATS.
Figure 15
Page 21
CB29M/CB30M SERIES
IMPORTANT
DAMAGED INSULATION MUST BE REPAIRED OR REPLACED before the unit is put back into operation. Insulation loses its insulating value when wet, damaged, separated or torn. Matt or foilfaced insulation is installed in indoor equipment to provide a barrier between outside air conditions (surrounding ambient temperature and humidity) and the varying conditions inside the unit. If the insulation barrier is damaged (wet, ripped, torn or separated from the cabinet walls), the surrounding ambient air will affect the inside surface temperature of the cabinet. The temperature/humidity difference between the inside and outside of the cabinet can cause condensation on the inside or outside of the cabinet which leads to sheet metal corrosion and subsequently, component failure. REPAIRING DAMAGED INSULATION Areas of condensation on the cabinet surface are an indication that the insulation is in need of repair. If the insulation in need of repair is otherwise in good condition, the insulation should be cut in an X pattern, peeled open, glued with an appropriate allpurpose glue and placed back against the cabinet surface, being careful to not overly compress the insulation so the insulation can retain its original thickness. If such repair is not possible, replace the insulation. If using foil-faced insulation, any cut, tear, or separations in the insulation surface must be taped with a similar foilfaced tape.
GLUE Make sure there is full coverage of glue on the metal or insulation so there are no areas where air pockets may form which can lead to sweating.
1. CUT INSULATION IN X PATTERN 2. APPLY GLUE 3. PRESS GLUED TABS AGAINST CABINET
WARNING
Electric Shock Hazard. Can cause injury or death. Foil-faced insulation has conductive characteristics similar to metal. Be sure there are no electrical connections within a " of the insulation. If the foilfaced insulation comes in contact with electrical voltage, the foil could provide a path for current to pass through to the outer metal cabinet. While the current produced may not be enough to trip existing electrical safety devices (e.g. fuses or circuit breakers), the current can be enough to cause an electric shock hazard that could cause personal injury or death.