Académique Documents
Professionnel Documents
Culture Documents
C B
MODEL
Absorbed Power kW
Dimensions mm A 455 455 455 530 530 605 605 605 B 197 197 197 282 282 352 352 352 C 450 450 450 600 600 700 700 700
Approx. Weight kg 18 18 20 32 33 46 55 55
Airflow correction factors for different working conditions (referred to 3C pressure dewpoint)
Correction Factors for Working Pressure
Pressure bar g Correction Factor 3 0.73 4 0.83 5 0.90 6 0.95 7 1.00 8 1.03 9 1.07 10 1.09 11 1.12 12 1.13 13 1.15 14 1.17 15 1.18 16 1.19
Performances refer to the following operating conditions: 7 bar g working pressure, 25C ambient temperature, 35C compressed air inlet temperature. All indicated data refers to ISO 7183. To obtain the required air flow multiply the value at 3C by the above correction factors.The above correction factors are approximative; for a precise selection always refer to the software selection program.
Ingersoll-Rand air compressors are not designed, intended, or approved for breathing air. Compressed air should not be used for breathing air applications unless treated in accordance with all applicable codes and regulations. Nothing contained in this brochure is intended to extend any warranty or representation, expressed or implied, regarding the products described herein. Any such warranties or other terms and conditions of sale shall be in accordance with Ingersoll-Rands standard terms and conditions of sale for such products, which are available upon request. Product improvement is a continuing goal at Ingersoll-Rand. Designs and specifications are subject to change without notice or obligation.
Air Solutions
ESA Business Centre Ingersoll-Rand European Sales Limited Swan Lane, Hindley Green Wigan WN2 4EZ, United Kingdom Tel: +44 (0) 1942 257171 Fax: +44 (0) 1942 254162 www.ingersoll-rand.com