1 2 2.1 2.2 3 3.1 3.2 3.3 3.4 3.5 3.6 4 4.1 4.2 4.3 4.4 4.5 5 6 Design of radio cells Cell selection/reselection Cell selection Cell reselection Handover General notes on handover Measurement preprocessing Measurement reporting and neighbor cell book-keeping Threshold comparisons and handover detection algorithms Target cell list generation Handover signaling and timer Handover types Handover types belonging to radio criteria Compression/Decompression HO Improvements Handover types belonging to network criteria Service dependent handover management AMR-handover Exercises Solutions 3 5 6 10 27 28 35 42 47 68 71 75 76 84 87 112 115 123 131
MN1789EU11MN_0001
2005 Siemens AG
Siemens
MN1789EU11MN_0001
2005 Siemens AG
Siemens
In textbooks on cellular mobile communications radio cells are idealized by regular hexagons, which has been proved to be a good model for explaining principle effects. However, in reality cell borders do not have this simple geometric structure. The physical cell borders are fixed on the one hand
by the algorithms which decide on changing from one serving base station to
another one on the basis of link quality measurements.
Cell Selection/Reselection (for the idle mode), Handover (for the connected mode)
and are described in detail in the following sections. Though it is controlled by some parameters broadcasted from the BS to the MS, the cell selection/ reselection algorithm itself is implemented in the MS. Therefore, it is specified in details by the GSM Recommendations (especially GSM 03.22 and GSM 05.08). In contrast, the handover decision algorithm is implemented in the BSS (assisted by downlink measurements reported by the MS). Hence, some degree of freedom is left to the manufacturer to optimize the algorithm. For this reason and because its very important to take the correct decision when the MS is in connected mode, the focal point of this chapter is the handover algorithm.
MN1789EU11MN_0001
2005 Siemens AG
Siemens
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Cell selection/reselection
MN1789EU11MN_0001
2005 Siemens AG
Siemens
As mentioned above, the cell selection/reselection algorithm is implemented in the MS. Because the algorithm for a GSM phase 1 MSs differs from that of a phase 2 MSs, both variants are described (as far as there is a difference).
2.1
Cell selection
Normal Cell Selection: Measurements for normal cell selection The MS takes 5 samples of the received level on each RF carrier which are averaged: AV_RXLEV = 1/5 * (RXLEV1 + RXLEV2 + ... + RXLEV5) These samples are spread evenly over a period of 3 - 5 s.
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Criteria for Cell Selection Based on these measurements one can estimate whether a cell will be an appropriate serving cell from the radio propagation point of view, i.e. whether there will be a sufficient link quality. This is done by checking the criterion C1 > 0. C1 = AV_RXLEV - RXLEV_ACCESS_MIN - Max(0, MS_TXPWR_MAX_CCH - P) => AV_RXLEV > RXLEV_ACCESS_MIN + Max(0, MS_TXPWR_MAX_CCH - P) This means that the received downlink level has to be above a threshold (RXLEV_ACCESS_MIN). To ensure a sufficient uplink received level even for MSs of low transmit power level P a further term is included: If P < MS_TXPWR_MAX_CCH (the maximum allowed MS transmit power level to access the random access channel), the C1 criterion is equivalent to AV_RXLEV > RXLEV_ACCESS_MIN + (MS_TXPWR_MAX_CCH - P) i.e. the received downlink level has to exceed the RXLEV_ACCESS_MIN by a certain margin to have a reserve for the uplink in the case of a MS of a low power class. Beside the C1 radio criterion there are some other criteria (administrative and traffic control) for a cell to be suitable:
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Definition: a Suitable Cell is defined as a cell which 1. is part of the selected PLMN, 2. is unbarred (parameter CELL_BAR_ACCESS = 0), 3. has a parameter C1 > 0, 4. is not in a location area forbidden for national roaming. To allow e.g. emergency calls the conditions for a serving cell are less restrictive: Definition: an Acceptable Cell is defined as a cell which 1. is unbarred, 2. has a parameter C1 > 0. The general strategy for cell selection is to find the suitable cell with the highest C1 (best estimated link quality). If no suitable cell can be found, an acceptable cell is selected. Note : For phase 2 mobile stations there is an additional cell selection parameter called CELL_BAR_QUALIFY (values: 0, 1) used to assign priorities to cells: CELL_BAR_QUALIFY = 0 CELL_BAR_QUALIFY = 1 <=> <=> normal priority cell low priority cell
First it is tried to select a suitable normal priority cell, if no such cell can be found, a suitable low priority cell is selected. This parameter is relevant only during the cell selection process. The complete cell selection process is illustrated in the flow chart below.
Cell Selection with Stored BCCH Information Optionally, the MS may store information on received level on BCCH carriers when switched off. When switched on, the MS first performs measurements on these carriers. If cell selection for the corresponding cells is not successful, normal cell selection is carried out.
MN1789EU11MN_0001
2005 Siemens AG
Siemens
no
yes
no
no
no
no
MN1789EU11MN_0001
2005 Siemens AG
Siemens
2.2
Cell reselection
While moving within the radio network in idle mode, another cell may be more appropriate to serve the MS. Therefore, cell reselection may be performed. Preconditions: The MS camps on a cell, which is called serving cell in the following. The following actions are performed by the MS to detect whether a cell reselection is necessary.
monitor all BCCH carriers given in the BCCH allocation (neighbor cells) of the
serving cell,
take at least 5 samples of the received level from the serving cell (on paging subchannel) as well as from the neighbor cells; => AV_RXLEV(serving cell) and AV_RXLEV (neighbor cell);
decoding of full BCCH data of the serving cell at least every 30 sec; decoding of BCCH data of the 6 strongest neighbor cells at least every 5 min.
From the radio propagation point of view it is worth to select a new (neighbor) cell if the received level from that neighbor cell exceeds the received level of the current serving cell. For phase 1 MSs this is expressed using the C1 criterion defined in the paragraph above: C1 (neighbor cell) > C1 (serving cell). For the reselection process for phase 1 MSs the neighbor cells are ordered according to their C1-value. For phase 2 MSs a modified path loss criterion, the so-called C2 criterion, is used. It is described in the following paragraph.
10
MN1789EU11MN_0001
2005 Siemens AG
Siemens
DSC0
-4 +1
DSC0=RND(90/BS_PA_MFRMS)
Fig. 2 Downlink signaling failure
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
11
Siemens
Cell Reselection Criterion C2 for MS of Phase 2: The C2 criterion depends upon the value of a timer T: A timer T is started in the MS for each cell in the list of the 6 strongest neighbor cells as soon as it is placed on the list. T is reset to 0 if the cell is removed from the list. C2 = C1 - CELL_RESELECT_OFFSET C2 = C1 + CELL_RESELECT_OFFSET TEMPORARY_OFFSET C2 = C1 + CELL_RESELECT_OFFSET The C2 criterion is illustrated in the figure below. for PENALTY_TIME = 31 and arbitrary T) for T < PENALTY_TIME < 31 else.
12
MN1789EU11MN_0001
2005 Siemens AG
Siemens
C2 TEMPORARY_OFFSET C1
CELL_RESELECT_OFFSET
PENALTY_TIME
A negative TEMPORARY_OFFSET reduces the priority of a cell in the list of strongest neighbor cells. A positive CELL_RESELECT_OFFSET increases the priority of a cell in the list of strongest neighbor cells. This mechanism may be applied in hierarchical cell structures to keep fast moving mobiles in the umbrella cells and slow moving mobiles in the micro cells: When a mobile reaches the coverage area of a (neighbor) micro cell given by the C1 criterion, this cell becomes effectively excluded from reselection during the PENALTY_TIME. A fast moving mobile is assumed to have left the coverage area of the micro cell before PENALTY_TIME is reached and hence the micro cell is not selected. In contrast, a slow moving mobile is assumed to be still within the coverage area of the micro cell when PENALTY_TIME has expired. Applying the positive CELL_RESELECT_OFFSET, this cell is selected with preference. This mechanism will be discussed in more detail when explaining the mobile speed sensitive handover in chapter 4 (Hierarchical Cell Structures).
MN1789EU11MN_0001
2005 Siemens AG
13
Siemens
Triggers for Cell Reselection Cell reselection is triggered by the following conditions: 1. C1 < 0 for the serving cell for a period of 5 s 2. MS detects downlink signaling failure 3. Serving cell becomes barred 4. a) Phase 1 MS C1 (serving cell) < C1 (suitable neighbor cell) if the suitable neighbor cell is in the same location area for a period of 5 sec. C1 (serving cell) + CELL_RESELECT_HYSTERESIS < C1 (suitable neighbor cell) if the suitable neighbor cell is in another location area for a period of 5 sec. b) Phase 2 MS C2 (serving cell) < C2 (suitable neighbor cell) if the suitable neighbor cell is in the same location area for a period of 5 sec. C2 (serving cell) + CELL_RESELECT_HYSTERESIS < C2 (suitable neighbor cell) if the suitable neighbor cell is in another location area for a period of 5 sec. 5. A random access attempt is unsuccessful even after the maximum number of repetitions. For phase 2 there is the additional trigger: 6. A location update request has been rejected with cause location area not allowed.
14
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Parameters for Cell Selection/Reselection BCCH_ARFCN_NC(n) BA - BCCH Allocation Object DB Name Range 0...1023 TRUE/FALSE (FALSE) Step Size Description 1 ARFCN used for BCCH by neighbor cell Parameter to include/exclude serving cell BCCH frequency in/from the BA list BTS / TGTBTS BCCHFREQ BTS EFCRECEL
In each cell the absolute radio frequency number BCCH_ARFCN_NC(n) (coding as given in chapter 1) each of its neighbor cell n has to be known. This information is broadcasted as the so called BCCH Allocation to all MSs in the respective cell. On the corresponding frequencies the MSs take measurement samples of the received level used for cell selection/reselection. Furthermore, the BCCH of neighbor cells has to be decoded by the MS (at least every 5 min) to know the current values of the control parameters for the reselection algorithm. The last SBS release gives an operator the opportunity to introduce the BCCH frequency of the serving cell in the BA list. This is done via parameter EFCRECEL. The benefit is much faster camp on of the MS. When switched on, due to stored last known BA list (that includes serving BA too) in a non-volatile memory, MS doesn't need to search for the BA. It camps immediately on the best cell-no need for cell reselection and therefore the call set up is also speed up. SYS_ID - System Identifier Object BTS DB Name SYSID Range BB900, DCS1800, F2ONLY900, EXT900, GSMR, PCS1900, GSMDCS, GSM850, GSM850PCS Description System Indicator indicates the frequency band used by traffic channels GSMDCS: F2ONLY900
Value to be set if cell supports Common BCCH bual band operation: Only phase 2 MS can be used, phase 1 not supported
GSM base band available for MS phase 1, exten.band for MS phase 2 EXT900
MN1789EU11MN_0001
2005 Siemens AG
15
Siemens
CELL_BAR_ACCESS - Cell Barred for Access Object BTS DB Name CELLBARR Range FALSE/TRUE Step Size Unit -
A mobile station cannot camp on a barred cell, i.e. a barred cell is not selected by the cell selection/reselection procedure. Mobile stations which camp on a cell while it becomes barred, initialize the reselection procedure to find a new (unbarred) cell, i.e. traffic load is distributed to neighbor cells. This means that e.g. neither a call nor a location update can start in a barred cell. However, a cell barred for access is not barred for incoming handovers. To barr a cell completely, e.g. for maintenance reasons also incoming handovers have to be avoided. To reduce overload in a certain cell more moderately without distributing the overload to neighbor cells, barring of MS access classes has to be used. Barring access for an access class does not trigger a cell reselection for MSs of that class. Access barring is done using the access classes specified by GSM (refer to GSM 08.08). There are 10 access classes (0...9) related to normal subscribers. The access class to which a subscriber belongs is derived from his IMSI. Furthermore, there are 5 classes (11...15) assigned to special high priority subscribers (e.g. police, PLMN operator.....).
16
MN1789EU11MN_0001
2005 Siemens AG
Siemens
MS_TXPWR_MAX_CCH - Maximum allowed MS Transmit Power on RACH Object BTS DB Name Range Step Size 1 Unit 2 dB
The MS_TXPWR_MAX_CCH field is coded as the binary representation of the power control level defined in GSM rec. 05.05. GSM900 Phase 1 0 1 2 3 15 = 43 dBm = 41 dBm = 39 dBm = 37 dBm : = 13 dBm 19 16 - 31 = 13 dBm GSM900 Phase 2 GSM850 0 1 2 3 = 39 dBm = 39 dBm = 39 dBm = 37 dBm : = 5 dBm 15 20 - 31 = 5 dBm 0 1 2 3 = 30 dBm = 28 dBm = 26 dBm = 24 dBm : = 0 dBm 15 30 31 16 - 31 = 0 dBm 0 1 2 3 = 30 dBm = 28 dBm = 26 dBm = 24 dBm : = 0 dBm = 33 dBm = 32 dBm 16 - 29 = 0 dBm DCS1800 PCS1900
The transmit power level the MS uses for the access on the random access channel is given by the minimum of two values:
the maximum output transmit power P of the MS (Power Class) the maximum allowed power for access within the respective cell
(given by MS_TXP WR_MAX_CCH).
Max. Output Power (GSM 900 Phase 2) -8 Watt = 39 dBm 5 Watt = 37 dBm 2 Watt = 33 dBm 0.8 Watt= 29 dBm
Max. Output Power (GSM 900 Phase 1) 20Watt = 43dBm 8 Watt = 39 dBm 5 Watt = 37 dBm 2 Watt = 33 dBm 0.8 Watt= 29 dBm
Max. Output Power (DCS 1800) 1 Watt = 30 dBm 0.25W = 24 dBm 4 Watt = 36 dBm
MN1789EU11MN_0001
2005 Siemens AG
17
Siemens
18
MN1789EU11MN_0001
2005 Siemens AG
Siemens
POWER_OFFSET - Additional Powerclass for Class 3 DCS1800 MS Object BTS DB Name PWROFS Range 0...3 Step Size 1 Unit 2 dB
The parameter POWER_OFFSET is only used by class 3 DCS1800 MS to calculate the C1-criterion described as follows. C1 = AV_RXLEV - RXLEV_ACCESS_MIN - Max(0,MS_TXPWR_MAX_CCH + POWER_OFFSET- P).
MN1789EU11MN_0001
2005 Siemens AG
19
Siemens
RXLEV_ACCESS_MIN - Minimum Downlink Received Level for cell to be selected Object BTS DB Name RXLEVAMI Range 0...63 (6) Step Size 1 Unit 1 dB
The parameter RXLEV_ACCESS_MIN determines the cell border for an MS in idle mode by means of the C1 or C2 criterion, respectively. Choosing a high value, reduces the risk of a handover immediately after call setup. On the other hand the value has to be low enough to achieve a sufficient overlap between adjacent cells (especially if they belong to different location areas). This is illustrated in the figure 3 for phase 1 MSs using the C1 criterion for cell reselection. It has to be observed that the overlap may be different for mobiles of different power classes (refer to MS_TXPWR_MAX_CCH). In any case RXLEV_ACCESS_MIN has to be above the MS receiver sensitivity level (-100 dBm for DCS1800, -102 dBm for GSM handhelds, -104 dBm for other GSM MSs). Furthermore, it has to harmonize with the handover thresholds (RXLEV_MIN, L_RXLEV_HO).
20
MN1789EU11MN_0001
2005 Siemens AG
Siemens
C1 BTS1
Phase 1 MS
BTS1
BTS2
CELL_RESELECT_ HYSTERESIS
C1=0
(h)
(l)
Radius of Cell 2 for selection (l) low power MS (h) high power MS
(b) Cell Reselection (a) no change of location area (b) change of location area
(a)
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
21
Siemens
CELL_RESELECT_HYSTERESIS - Hysteresis for Reselection of a Cell from another Location Area Object BTS DB Name CELLRESH Range 0...7 (2) Step Size 1 Unit 2 dB
In idle mode the MS selects a new (neighbor) cell if the received level of the neighbor cell exceeds the received level of the current cell in order to be served by the cell with the expected best link quality. However, due to fading effects, the propagation conditions may change rapidly and therefore a reselection may occur very frequently. If the cells involved in the reselection process belong to the same location area, frequent cell reselection does not have an effect on the network performance. But if the involved cells belong to different location area, the reselection of a new cell triggers a location update procedure, which causes signaling load (e.g. on the SDCCH) and involves all network elements. To avoid unnecessary signaling load by forward and backward reselection due to fading, a hysteresis given by the parameter CELL_RESELECT_HYSTERESIS is introduced, i.e. a cell from another location area is selected only if the corresponding received level exceeds the level of the current serving cell by the value of this parameter. This is expressed in terms of the C1 (phase 1) or C2 (phase 2) criterion: C1(serving cell) + CELL_RESELECT_HYSTERESES (serving) < C1 (suitable neighbor cell) or C2 (serving cell) + CELL_RESELECT_HYSTERESES(serving) < C2 (suitable neighbor cell) respectively. The adjustment of CELL_RESELECT_HYSTERESES should be a compromise between
reduction of unnecessary location updates (high value) and selection of the cell with best reception quality (low value).
22
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Additional Phase 2 Parameters for Cell Selection/Reselection CELL_BAR_QUALIFY Object BTS normal priority: low priority: DB Name CBQ 0 1 Range 0...1 (0) Step Size 1 Unit -
Parameter used to assign a priority to a cell selection process. A suitable cell of low priority is only selected if no suitable cell of normal priority can be found. This parameter can be used e.g. in hierarchical cell structures that the MS initially selects an umbrella cell.
CELL_RESELCT_PARAM_IND_ - Phase 2 Reselection Parameter Indication Object BTS DB Name CRESPARI Range 0...1 (1) Step Size Unit -
CELL_RESELECT_PARAM_IND=1: The cell reselection parameters CELL_RESELECT_OFFSET, TEMPORARY_OFFSET and PENALTY_TIME used for the C2 criterion as well as the parameter CELL_BAR_QUALIFY are broadcasted on the BCCH. These parameters are taken into account by phase 2 MSs, but are ignored by phase 1 Mss. CELL_RESELECT_PARAM_IND = 0: The cell reselection parameters and CELL_BAR_QUALIFY are not broadcasted on the BCCH. A phase 2 MS then uses the value 0 for all these parameters, i.e. C1 = C2.
MN1789EU11MN_0001
2005 Siemens AG
23
Siemens
PENALTY_TIME - Time to apply a negative Offset to C2 of a Neighbor Cell Object BTS DB Name PENTIME Range 0...30 and 31 (5) Step Size 1 Unit 20 sec
PENALTY_TIME = 20 sec + PENTIME 20 sec A timer T is started in the MS for each cell in the list of the 6 strongest neighbor cells as soon as it is placed on the list. T is reset to 0 if the cell is removed from the list. During Penalty Time (T < PENALTY_TIME) a negative TEMPORARY_OFFSET is applied to the C2 of the respective neighbor cell C2 = C1 + CELL_RESELECT_OFFSET - TEMPORARY_OFFSET which is removed after Penalty Time (T > PENALTY_TIME): C2 = C1 + CELL_RESELECT_OFFSET. PENALTY_TIME = 31: C2 = C1 - CELL_RESELECT_OFFSET. For PENALTY_TIME = 31 the priority of a neighbor cell for reselection is permanently reduced.
TEMPORARY_OFFSET Object BTS DB Name TEMPOFF Range 0...7 (1) Step Size 1 Unit 10 dB 7: infinity
Subtracting TEMPORARY_OFFSET from CELL_RESELECT_OFFSET reduces the priority of a cell in the list of strongest neighbor cells, i.e. during run time of the timer the corresponding neighbor cell is effectively barred for cell reselection.
24
MN1789EU11MN_0001
2005 Siemens AG
Siemens
CELL_RESELECT_OFFSET Object BTS DB Name CRESOFF Range 0...63 (1) Step Size 1 Unit 2 dB
Adding CELL_RESELECT_OFFSET increases the priority of a cell in the list of strongest neighbor cells when the timer has expired. This mechanism may be applied in hierarchical cell structures to keep fast moving mobiles in the umbrella cells and slow moving mobiles in the micro cells: When a mobile reaches the coverage area of a (neighbor) micro cell, given by the C1 criterion, this cell becomes effectively excluded from reselection during the PENALTY_TIME. A fast moving mobile is assumed to have left the coverage area of the micro cell before PENALTY_TIME is reached and hence the micro cell is not selected. In contrast, a slow moving mobile is assumed to be still within the coverage area of the micro cell when PENALTY_TIME has expired. Applying the positive CELL_RESELECT_OFFSET, this cell is selected with preference.
MN1789EU11MN_0001
2005 Siemens AG
25
Siemens
26
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Handover
MN1789EU11MN_0001
2005 Siemens AG
27
Siemens
3.1
The handover algorithm is the most important algorithm in cellular mobile communications. Its main objectives are:
maintenance of connection in case of cell change (movement) channel change in case of severe disturbance (interference) design of cell borders and radio network structure.
Steps of the Handover Process The handover process can be divided into several sub-processes listed in the table below together with the network elements involved within the respective process. No. 1. Sub-process Measurements link quality serving cell received level neighbor cells traffic load 2. 3. 4. 5. 6. Measurement Preprocessing Neighbor cell book-keeping Handover Decision Target Cell Generation Target Cell Evaluation intra BSS handover inter BSS handover 7. 8. Selection of new channel Handover execution BSC MSC BSC MS, BTS, BSC, MSC MS, BTS MS BTS BTS BTS BTS BTS Involved Network Element
28
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Types of Handover Different types of handover can be distinguished with respect to the changed region: a cell, a BSS area or an MSC area. These are illustrated in the figure below. The different types of handover can enabled or disabled by several flags.
BSC 1a 2
BSC 2
MSC 1
MSC 2
3 BSC 1b
MN1789EU11MN_0001
2005 Siemens AG
29
Siemens
Handover Causes Two criteria groups of different handover causes are defined: Radio Criteria 1 2 3 4 5 Network Criteria 6 7 8 9 received quality (too low/bit error rate too high) received level (too low) received UL-level (too low) /fast measurement MS-BS distance (too high) better cell (power budget: relative received level) serv. cell congestion > directed retry for call setup traffic load (too high) MS-BS distance (too high/low in extended cells) received level or MS-BS distance (too low/high in concentric cells) inter-/intracell HO intercell HO intercell HO intercell HO intercell HO intercell HO intercell HO intracell HO intracell HO
30
MN1789EU11MN_0001
2005 Siemens AG
Siemens
The first four causes are known as mandatory or imperative causes, i.e. if one of these causes occurs, a hand-over is necessary to maintain the call. This may happen because the MS is leaving the coverage area of the serving cell (intercell handover) or because there is a strong interferer using the same channel in another cell (intracell handover). The fifth cause is an optional one, i.e. the link quality in the serving cell is sufficiently good, but there are neighbor cells with better received level. Though it is not necessary for the link quality of this specific call, there is a benefit for overall network performance to handover the call to the better cell: A call in the better cell causes less interference, especially, if power control is applied. The same received level in the better cell is achieved with a smaller transmit power in this cell. In a well planned radio network better cell should be the overwhelming handover cause. Hence, the locations of a better cell handover determine the cell boundaries. The sixth cause is named forced handover because it is triggered by the BSC due to a congestion situation, and not due to radio conditions on the link. This handover (directed retry) is performed from a SDCCH in the congested cell to a TCH in a neighbor cell during call setup. The seventh cause is named 'Handover decision due to BSS resource management'. The criteria (traffic load) are evaluated in the BTS; if a BTS detects a high traffic load, a handover cause is triggered and an intercell handover execution starts. The last two causes are intracell handovers in special cell configurations:
in extended cells handovers are feasible from single to double timeslots and vice
versa. area.
In a concentric cell handovers are performed between the inner and complete
These handover causes can be enabled/disabled separately by corresponding flags.
MN1789EU11MN_0001
2005 Siemens AG
31
Siemens
Flags to enable/disable Handover Types and Causes due to Radio Criteria The flags to enable/disable the different handover types and causes are listed in the tables below. They are administered in the object HAND with the range TRUE / FALSE. Specification Name EN_INTER_HO EN_INTRA_HO DB Name INTERCH INTRACH Meaning Flag to enable/disable all handover types and causes except for intracell handover. Flag to enable/disable intracell handover. Flag to enable/disable a BSS internal intercell handover, i.e. if disabled, the handover is handled as an inter BSS handover even if the first cell in the target cell list belongs to the same BSS as the serving cell. Flag to enable/disable a BSS internal intracell handover, i.e. if disabled, the handover is handled as an inter BSS handover and the MSC is involved. Flag to enable/disable intercell handover due to quality. Flag to enable/disable intercell handover due to level. Flag to enable/disable intercell handover due to distance. Flag to enable/disable better cell (power budget) handover. Flag to enable/disable intercell handover due to BSS resource management criteria Flag to enable/disable the Fast Uplink Handover Flag to enable/disable intercell SDCCH Handover Flag to enable/ disable intracell SDCCH Handover
EN_TRAFFIC_H TRFHOE O EN_FUL_HO EN_INTER_ SDCCH_HO EN_INTRA_ SDCCH_HO IRACHOSDCCH EFULHO IERCHOSDCCH
32
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Flag to enable/disable Level Handover Margin for Level Handover Flag to enable/disable Level Handover Margin for Quality Handover Flag to enable/disable Intersystem Handover to UMTS Flag to enable/disable better cell (power budget) handover to UMTS Flag to enable/disable sufficient coverage handover to UMTS Flag to enable/disable imperative handover to UMTS Flag to enable/disable directed retry to UMTS
EN_UMTS_BETTER_ EUBCHO CELL_HO EN_UMTS_SUFF_CO EUSCHO V_HO EN_UMTS_IMPERAT EUIMPHO IVE_HO EN_UMTS_SDCCH_ HO EUSDCHO
The following three flags to enable/ disable HO are administered in the object SET BSC . DB Name Specification Name EN_FORCED_ INTRA_HO EN_INTER_ SDCCH_HO EN_FORCED HO ENFORCHO EISDCCHHO EFOIAHO Flag to enable/disable forced Intracell Handover due to multislot call Flag to enable/disable Inter BSC SDCCH Handover. Flag to enable /disable Forced Handover Meaning
MN1789EU11MN_0001
2005 Siemens AG
33
Siemens
Comments
channel with high interference to another one with less interference within the same cell. However, if random frequency hopping (see chapt. 6.2) is applied, it may be reasonable to disable intracell handover since interference is approximately the same on all channels and no improvement can be achieved by intracell handover. boundaries in the case of favorable radio conditions at the serving cell without causing a handover. As a consequence, neighboring cells may suffer from excessive interference produced by this MS. Furthermore, there is a risk that link quality decreases very suddenly (turn around a corner), i.e. there is the risk of a call drop. Hence, distance handover should be switched on. generated. Nevertheless, power budget is calculated and evaluated for the ranking of neighbor cells within the target cell list, which also has to be compiled for mandatory handovers.
If power budget handover is disabled, no handovers with cause better cell are
34
MN1789EU11MN_0001
2005 Siemens AG
Siemens
3.2
3.2.1
Measurement preprocessing
Measurement Values
The following parameters are measured and calculated each SACCH multiframe (0.48 s): RXQUAL It is defined according to GSM TS 05.08 as function of the bit error rate (BER) before channel decoding: RXQUAL = 0 RXQUAL = 1 RXQUAL = 2 RXQUAL = 3 RXQUAL = 4 RXQUAL = 5 RXQUAL = 6 RXQUAL = 7 : : : : : : : : 0.2% 0.4% 0.8% 1.6% 3.2% 6.4% 12.8% < < < < < < < BER BER BER BER BER BER BER BER < < < < < < < 0.2% 0.4% 0.8% 1.6% 3.2% 6.4% 12.8% assumed value: assumed value: assumed value: assumed value: assumed value: assumed value: assumed value: assumed value: 0.14% 0.28% 0.57% 1.13% 2.26% 4.53% 9.05% 18.01%
The RXQUAL values are measured on the dedicated channel for the uplink as well as for the downlink for each TDMA frame (100 frames) within an SACCH multiframe. The measured RXQUAL values in [dBm] are averaged over the respective SACCH period using the assumed values of the table above. The resulting RXQUAL value is the one used within the handover algorithm in the way described below. RXLEV The received level is measured on the dedicated channel for the uplink as well as for the downlink for each TDMA frame (100 frames) within an SACCH multiframe. The measured level values are averaged over the respective SACCH period. The average value is mapped on an RXLEV value using the table below (refer to GSM TS 05.08): RXLEV = 0: RXLEV = 1: RXLEV = 2: RXLEV = 62: RXLEV = 63: - 110 dBm - 109 dBm - 49 dBm < < < RXLEV RXLEV RXLEV RXLEV RXLEV > - 110 dBm - 109 dBm - 108 dBm - 48 dBm - 48 dBm
MN1789EU11MN_0001
2005 Siemens AG
35
Siemens
RXLEV_NCELL(n) The mobile measures the level received on the BCCH frequency of each neighbor cell n. The mapping is as for RXLEV above. MS_BS_DIST The distance MS_BS_DIST between the MS and BS is calculated from the timing advance (TA) value measured by the BS and is coded as follows: MS_BS_DIST = 0, 1, ... 35. Distance[Km]. Aspects of Discontinuous Transmission When Voice Activity Detection (VAD) and Discontinuous Transmission (DTX) is applied not all TDMA frames within a SACCH multiframe may be transmitted. Hence, RXQUAL and RXLEV measurement values (SUB values) for the corresponding SACCH frames are less reliable than those for that SACCH with no silence period (FULL values). Therefore SUB and FULL values have to be distinguished within measurement preprocessing (see below).
idle slot
speech burst
SACCH burst
Fig. 6
36
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Measurement Values for Handover (Summary) Measurement RXLEV_DL_FULL RXLEV_DL_SUB RXQUAL_DL_FULL RXQUAL_DL_SUB DTX_USED RXLEV_NCELL(1..6) Range 0 - 63 0 - 63 0-7 0-7 0.-.1 0 - 63 Measurement Type Description Received signal level on TCH/SDCCH (full set of TDMA frames) downlink Received signal level on TCH (subset of TDMA frames) downlink Received signal quality on TCH/SDCCH (full set of TDMA frames downlink Received signal quality on TCH (subset of TDMA frames) downlink DTX used/not used on uplink in previous frame Received signal level on BCCH of up to 6 neighbor cells (downlink) BCCH RF channel number of up to 6 neighbor cells (downlink) Base Station Identity Code of up to 6 neighbor cells (downlink) Received signal level on TCH/SDCCH (full set of TDMA frames) uplink Received signal level on TCH (subset of TDMA frames) uplink Received signal quality on TCH/SDCCH (full set of TDMA frames) uplink Received signal quality on TCH (subset of TDMA frames) uplink Absolute MS-BS distance [km]
BCCH_FREQ_NCELL_(1...6) 0 - 31 BSIC_NCELL (1...6) NCC-BCC RXLEV_UL_FULL RXLEV_UL_SUB RXQUAL_UL_FULL RXQUAL_UL_SUB MS_BS_DIST 0 - 63 0 - 63 0-7 0-7 0 - 35 0-7
MN1789EU11MN_0001
2005 Siemens AG
37
Siemens
3.2.2
The measured (and reported) data per SACCH multiframe are preprocessed within the BTS using a gliding average window, as the window works as a queue: when a new measurement is received the oldest one is removed from the window. The ''averaging period'' defines the size of the gliding averaging window for the measured values. the size of the averaging size determines the number of measurement samples) the new measurement sample is received every 480ms from the BTS or the MS) over which the BTS calculates the arithmetic average. The size of the window can be set separately for RXQUAL, RXLEV, DIST and PBGT. The measured RXLEV_FULL/SUB or RXQUAL_FULL/SUB values are put into the gliding window. The DTX weighting factor determines how much more the FULL values shall be weighted for radio measurements results measured over a period with voice activity. The current weighting factor given by the parameter W_LEV_HO or W_QUAL_HO is stored in parallel under the same offset as illustrated in the figure below. The averaging window total is calculated by adding up all sample values currently stored within the averaging window while a single sample is added number of "weight" times. Then the total is divided by the "weight" total (all ''weight'' values within the averaging window are added up).
Example: Averaging of RXLEV when DTX enabled: : average of RXLEV with a gliding window of size and a weight factor of the full values of A_LEV_HO = 4 W_LEV_HO = 2.
38
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Gliding Window Averaging size=4 average value = 28 28 1 31 1 32 2 27 2 22 1 28 2 21 1 ai sample value wi waiting factor of the sample value Measurement sample value obtained each SACCH Multiframe (0.48s or 0.471s RXLEV_FULL (weight 2)
ai wi
28 1
31 1
32 2
27 2
22 1
28 2
21 1
RXLEV_SUB (weight 1)
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
39
Siemens
Parameters for Measurement Preprocessing The parameters for measurement preprocessing for handover are administered in the object HAND and are listed in the table below. Specification Name A_QUAL_HO DB Name HOAVQUAL AQUALHO HOAVQUAL WQUALHO HOAVLEV ALEVHO HOAVLEV WLEVHO HOAVDIST Range 1-31 (6) 1-3 (2) 1-31 (8) 1-3 (2) 1-31 (8) A_PBGT_HO HOAVPWRB 1-31 (8) Meaning Averaging window size for RXQUAL values, used for handover decisions due to RXQUAL Weighting factor for RXQUAL_FULL values Averaging window size for RXLEV values, used for handover decisions due to RXLEV Weighting factor for RXLEV_FULL values Averaging window size for Timing Advance values used for handover decisions due to distance. Averaging window size used for power budget calculation. Averaging is applied to: RXLEV_DL PWR_C_D RXLEV_NCELL Averaging window size used for Fast Uplink Handover detection and target cell list generation Weighting factor used for Fast Uplink Handover detection and target cell list generation
W_QUAL_HO A_LEV_HO
W_LEV_HO A_DIST_HO
A_LEV_FUL_HO
ALEVFULHO ALEVFULHO
1...31 (2)
W_LEV_FUL_HO
40
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Range of A_XX: 1...31, Step Size: 1 The adjustment of the averaging size mainly depends upon rate of change of the
radio propagation conditions.
Example: path loss (change of 3 dB at a distance of 2000 m) long term fading change of 6 dB short term fading MS movement of 5...100 m MS movement of 0.15 m MS movement of 400 m
Hence, at the cell border the main variation of received level is due to long and short term fading. Within one SACCH multiframes an MS moves 0.5 m 5.0 m for MS speed = 1 m/s = 3.6 km/h for MS speed = 10 m/s = 36 km/h
Using an averaging window size of 10 SACCH frames, short term fading is averaged for pedestrians (as well as for fast moving MSs). Long term fading is partly averaged for fast moving MSs (the degree of average depends on the exact speed and the correlation length of long term fading, whereas there is nearly no averaging of long term fading for pedestrians. The setting of the averaging window size has to be a compromise between a fast decision and a reliable decision. Therefore it is recommended to use a larger window size for the optional handover (better cell) to do not cause a lot of unnecessary handovers and a smaller window size for the mandatory handover causes (quality, level, distance) to be able to react quickly on a sudden decrease of link quality.
MN1789EU11MN_0001
2005 Siemens AG
41
Siemens
3.3
NOTE Number of adjacent neighbor cells (object Create ADJC) is extended from 32 to 64. Up to 32 of them can be active adjacent cells used for cell reselection or/and HO if the parameter USG (object Create ADJC), if SI_2 or SI_5/SI_2_5 respectively. The parameter may have an additional new value introduced in BR8.0 USG=INACTIVE which indicates that adjacent cell is inactive, i.e. not to be used for cell reselection or/and HO but for measurements purposes only. A cell's BCCH is then included into 'measure extra BCCH frequencies' but only if the new parameter in the object Create BTS MEAEXTBCCH=TRUE. Up to 64 inactive and in active adjacent cells can be configured in total. If less then 32 adjacent cells are active more then 32 can be included in extra BCCH measurements.
42
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Parameters for measurement reporting and neighbor cell book-keeping The parameters for measurement reporting and target cell generation of the object BTS are summarized in the table below. DB Name CELLGLID Object BTS /TGTBTS Range 0...999 0...999 1...65535 0...65535 0...1023 Meaning Global cell identifier of the adjacent cell consisting of mobile country code, mobile network code, location area identifier and cell identity Absolute radio frequency channel number of the BCCH frequency of the neighbor cell. Base station identity code consisting of national- and base station-color code. Neighbor cell measurement are identified using BSIC and BCCH_FREQ_NCELL The MS includes only received level values of those cells within the measurement report which are defined as cells of a permitted PLMN Number of preferred cells for HO Enable /disable feature 'Measure Extra BCCH' Parameter indicates whether the adjacent cell must be sent over System Info 2, 5 or both or is used only for measurement purposes (inactive)
BCCHFREQ
0...7 0...7
PLMNP
BTS
0...255
MN1789EU11MN_0001
2005 Siemens AG
43
Siemens
44
MN1789EU11MN_0001
2005 Siemens AG
Siemens
MN1789EU11MN_0001
2005 Siemens AG
45
Siemens
46
MN1789EU11MN_0001
2005 Siemens AG
Siemens
3.4
Up- and downlink measurements of level and quality The absolute MS-BS distance The power budget criterion of up to 32 neighbor cells BSC-trigger to answer with a HO Condition Indication message
Two types of handover may occur:
Intercell HO requests the allocation of a dedicated channel outside the serving cell Intracell HO requests the allocation of another dedicated channel within the
serving cell GSM distinguishes three classes of handover criteria:
Power budget HO as normal criterion All other TCH-causes as alarm- or imperative criteria Forced HO triggered by the BSC
MN1789EU11MN_0001
2005 Siemens AG
47
Siemens
3.4.1
Decision criteria
The standard handover algorithm for radio criteria uses the decision criteria listed in the table below where the order of processing within the overall handover algorithm is used (see Fig. 9). These criteria will be modified for a speed sensitive handover used within hierarchical cells (chapter 4). Handover Causes Intercell HO due to Quality Decision Criteria 9. RXQUAL_XX > L_RXQUAL_XX_H 10. RXLEV_XX < L_RXLEV_XX_IH * 11. XX_TXPWR = Min ( XX_TXPWR_MAX, P ) HO due to Level HO due to Distance HO due to Power Budget 12. RXLEV_XX < L_RXLEV_XX_H 13. XX_TXPWR = Min ( XX_TXPWR_MAX, P ) 14. MS_BS_DIST > MS_RANGE_MAX 15. RXLEV_NCELL(n) > RXLEV_MIN(n) + Max ( 0, MS_TXPWR_MAX(n) - P ) 16. PBGT(n) > HO_MARGIN(n) Intracell HO due to Quality Fast HO due to UL-Level 17. RXQUAL_XX > L_RXQUAL_XX_H 18. RXLEV_XX > L_RXLEV_XX_IH 1. RXLEV_UL < THR_RXLEV_FAST_UL_HO * parameter INTRACH =TRUE
Notes
used as variable for both UL (uplink) and DL (downlink) maximum allowed transmit power of the MS in the serving cell, maximum allowed transmit power of the MS in the adjacent cell n the maximum power capability of the MS (power class)
An intercell handover due to quality or level is only performed if the transmit power
of the MS or BS respectively is on its maximum.
48
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Handover Regions
XX=UL : Uplink
Bit-Error-Rate (RXQual)
Handover
Intra-cell handover due to quality (if skip flag=FALSE) Inter-cell handover due to quality (if skip flag=TRUE or if INTRACH=FALSE)
L_RXQual_XX_H
HOLTHQUXX
HOLTHLVTXX
HOTXXINT
XX=DL : Downlink XX UL U li k
L_RXLev_XX_H
L_RXLev_XX_IH
Level (RXLev)
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
49
Siemens
Power Budget: Power Budget is calculated in the following way: PBGT(n) = RXLEV_NCELL(n) - ( RXLEV_DL + PWR_C_D ) + Min( MS_TXPWR_MAX, P ) - Min( MS_TXPWR_MAX(n), P ) > HO_MARGIN(n) RXLEV_DL: PWR_C_D: averaged value of the measured downlink level in the serving cell, BS_TXPWR_MAX [dBm] - BS_TXPWR [dBm] Averaged difference between the maximum downlink RF power BS_TXPWR_MAX and the currently used downlink power BS_TXPWR (due to power control) in the serving cell. RXLEV_NCELL(n) Averaged value of the measured downlink level of the adjacent : cell n HO_MARGIN(n): Handover margin; if path loss with respect to the serving cell exceeds the path loss with respect to the adjacent cell n by this margin, the adjacent cell is considered as the (much) better cell.
Loss(serving) - Loss(adjacent) = = BS_TXPWR - RXLEV_DL - (BS_TXPWR_MAX(n) - RXLEV_NCELL(n)) = RXLEV_NCELL(n) - (RXLEV_DL + PWR_C_D) + BS_TXPWR_MAX - BS_TXPWR_MAX(n). Assumption: BS_TXPWR_MAX - BS_TXPWR_MAX(n) = MS_TXPWR_MAX - MS_TXPWR_MAX(n)
50
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Parameters of Handover Decision Specification Name L_RXQUAL_DL_H L_RXQUAL_UL_H DB Name/ Object HOLTHQUDL HOLTHQUUL /HAND Range 0...7 (5) Meaning Thresholds for downlink/uplink quality. If RXQUAL is above these thresholds, the received level is low and the transmit power has reached its maximum, a quality intercell handover is initiated. Thresholds for downlink/uplink level. If RXLEV is below these thresholds and the transmit power has reached its maximum a level handover is initiated. If the quality falls below a threshold, but the received level is high, higher than L_RXLEV_XX_IH, an intracell handover is initiated. If the measured timing advance value is above this threshold, a distance handover is initiated in a standard cell. Unit: 1Km If the measured timing advance value is above this threshold, a distance handover is initiated in an extended cell. Unit: 1Km Receive signal strength threshold for an intercell Fast Uplink HO decision
L_RXLEV_DL_H L_RXLEV_UL_H
0...63 (10/8)
L_RXLEV_DL_IH L_RXLEV_UL_IH
0...63 (35)
MS_RANGE_MAX
HOTMSRM /HAND
0...35 (34)
MS_RANGE_MAX_EXT
HOTMSRME /HAND
35...100 (99)
0...63 (8)
MN1789EU11MN_0001
2005 Siemens AG
51
Siemens
Maximum TXPWR an MS is allowed to use in the neighbor cell n 2 = 39 dBm, 15 = 13 dBm (GSM) 0 = 30 dBm, 15 = 0 dBm (DCS)
RXLEV_MIN(n)
RXLEVMIN /ADJC
0...63 (12)
The level received from a neighbor cell n has to exceed this threshold
handover to that neighbor cell target cell list for a mandatory handover.
52
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Handover Scenarios For adjusting the handover thresholds one has to distinguish two scenarios: A) Noise Limited Scenario: Large cells (in rural area) with low traffic load: received level at the cell border not much above the receiver limit sensitivity level. B) Interference Limited Scenario: Small cells (in urban area) with high traffic load: received level at cell border significantly exceeds the receiver sensitivity level, but C/I not much above the reference interference sensitivity. In any case intercell handover due to quality should be avoided as far as possible, i.e.
set L_RXQUAL_XX_H to highest value for acceptable speech quality, set L_RXLEV_XX_IH to a appropriate value so that in case of low RXQUAL an
intracell handover is initiated for the locations within the cell area defined by the other thresholds.
Scenario A: Main handover criterion is the level criterion and L_RXLEV_XX_H has to be set to a value just some dBs above the receiver limit sensitivity level. Furthermore, there should be a hysteresis between the threshold RXLEV_MIN for incoming handover and the corresponding one for outgoing handover L_RXLEV_XX_H to avoid a lot of unnecessary forward and backward handover: RXLEV_MIN - L_RXLEV_XX_H = level hysteresis > 0. The order of magnitude for the level hysteresis is given by the standard deviation of the long term fading, i.e. RXLEV_MIN > L_RXLEV_XX_H + 4 ... 10 dB.
MN1789EU11MN_0001
2005 Siemens AG
53
Siemens
Scenario B In this scenario the better cell criterion should be the main handover criterion, since
it is the most suitable criterion for designing well defined cell borders, it guarantees that the mobile is served by the cell with (nearly) the lowest path loss
and therefore offers the greatest potential for power control to reduce interference. To avoid a lot of unnecessary forward and backward power budget handover caused by long term fading fluctuations of the received levels from the respective BTSs, a hysteresis has to be introduced:HO_MARGIN(cell1 -> cell2) + HO_MARGIN(cell2 -> cell1) = power budget hysteresis > 0. Usually, the handover margin is chosen symmetrically; its value should be a compromise between ideal power budget handover (low value) and a low rate of forward and backward handovers (high value). By choosing unsymmetrical values for the handover margin, one can adapt the cell area to the traffic load, e.g. increasing HO_MARGIN(cell1 -> cell2) while keeping the power budget hysteresis constant (i.e. reducing HO_MARGIN(cell2 -> cell1) by the same amount), increases the effective area of cell 1 while reducing that of cell 2). RXLEV_MIN(n) should be set to a value so that RXLEV_NCELL(n) > RXLEV_MIN(n) for almost all locations where PBGT(n) > HO_MARGIN(n), i.e. a better cell handover is really initiated if the power budget condition is fulfilled. This means that there should be an overlap of the outgoing power budget area of one cell and the incoming RXLEV_MIN area of the neighbor cell n. Furthermore, as for scenario A, there should be a level hysteresis between RXLEV_MIN and L_RXLEV_XX_H. This is illustrated for an ideal situation without long term fading in the figure below:
54
MN1789EU11MN_0001
2005 Siemens AG
Siemens
RXLEV_MIN
L_RXLEV_XX_H
BT S1
BT S2
BTS
RXLEV_MIN (incoming HO) L_RXLEV_XX_H (outgoing level HO) receiver limit sensitivity
MN1789EU11MN_0001
2005 Siemens AG
55
Siemens
3.4.2
On TCHs it is possible that the condition for more than one handover cause is fulfilled. Therefore it is necessary to rank the evaluation of handover causes. On SDCCH where only one cause is evaluated, no ranking is necessary. Static ranking is performed according a priority list given in the following table. Priority 1 2 3 4 5 6 7 8 Handover Cause Extended Cell Handover Concentric Cell Handover Quality Intercell Handover Level Handover Distance Handover UMTS Sufficient Coverage Handover Power Budget Handover Quality Intracell Handover Traffic Handover Forced Handover Fast Uplink Handover HO type intracell intracell intercell intercell intercell intercell intercell intracell intercell intercell intercell HO class imperative imperative imperative imperative imperative normal normal imperative normal forced imperative evaluated on TCH TCH TCH TCH TCH TCH TCH TCH BTS SDCCH UL-TCH
56
MN1789EU11MN_0001
2005 Siemens AG
Siemens
HO detected Y
HO detected Y
HO detected Y
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
. . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
57
Siemens
Handover Criteria Evaluation - Dynamic Ranking In some cases it is necessary to rank priorities dynamically to avoid hanging on one HO criteria: in case a extended cell HO (single/double timeslot) or an Concentric Cell HO (inner/complete area) was requested but could not be performed due to lack of resources, evaluation of these criteria is skipped the next time to make evaluation of other HO criteria possible (e.g. Quality, Level etc.). In case the following HO-attempt is also unsuccessful or no other HO can be detected then the skipped priority is enabled again for the next try. BTS toggles. Dynamic ranking of HO evaluation is also performed in case of Quality inter/intracell HO. The following flow chart shows in principle the dynamic ranking mechanism of Extended Cell HO/Concentric Cell HO.
58
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Reset skip_flag
HO condition fulfilled Y
Set skip_flag
HO detected
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
59
Siemens
3.4.3
3.4.3.1
When criteria for Quality Intercell HO are evaluated it is first checked if any Quality handover shall be performed (averaged UL/DL measurements show a high signal quality value). Then the criterion of Quality Intracell handover is evaluated. Its obvious that Quality Intercell HO is detected when the criterion of Quality Intracell HO is not given. In case a Quality Intracell HO was requested but could not be performed (HO_FAILS) than Quality Intercell HO is tried the next time (if criterion is still given). When this Intercell HO attempt also fails then BTS toggles back and tries again an Intracell HO. To initiate a Quality Intercell HO after an unsuccessful Quality Intracell HO attempt, a skip_flag algorithm is used. This skip_flag is set after an Intracell HO attempt and is processed in case of Quality Intercell detection. The dynamic ranking mechanism forces an Intercell HO instead of the previous Intracell HO by skipping the evaluation for Quality Intracell HO condition. The skip_flag is reset again to make a future Intracell HO evaluation possible in case this Intercell HO attempt also fails, BTS toggles between intracell and intercell handover.
60
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Max. power Y Condition for Quality HO fulfilled Y Skip Intracell HO (skip_flag set) Y Y reset skip_flag
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
61
Siemens
3.4.3.2
The BTS is informed by the BSC that a number of consecutive and successful Intra Cell HO over the same connection have been performed. Any further subsequent Intracell HO has to be disabled for a defined period of time, but if criteria are given during penalization time a Intercell HO may be tried instead. The O&M flag Enable_Limitation_Intracell_HO is used to enable/disable this feature. The attribute Max_Intracell_HO specifies the maximum number of consecutive successful quality intracell handovers, which are permitted in the same BTS for a single connection. The next intracell HO is suspended when the threshold Max_Intracell_HO+1 is reached, until the Timer_No_Intracell_HO expires. Parameters for Intracell handover limitation Specification Name Enable_Limitation_ Intracell_HO Max_Intracell_HO Timer_No_Intracell_HO Object HAND HAND HAND DB Name ELIMITCH MAIRACHO TINOIERCHO Range TRUE/ FALSE 1 .. 15 (2) 1.. 254 (60) Step Size 1 1 Unit 1 sec
The following configuration rule should be regarded: TINOIERCHO (BTS timer) > THORQST (BTS timer) > T7 (BSC timer). This condition allows the possibility to perform an intercell handover.
62
MN1789EU11MN_0001
2005 Siemens AG
Siemens
TRX:0
TRX:4
TRX:1
BTS
TRX:3
TRX:2
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
63
Siemens
3.4.4
In some cases back handovers, i.e. handovers to a cell just left before, should be avoided. Back-handover (due to power budget) prevention is triggered by BSC by including the old cell and the previous handover cause (GSM 08.08 Cause) in the Channel activation message. A timer is started in BTS and until the timer for the specified cell expires,
no handover condition due to Power Budget will be evaluated for this cell this cell is excluded from the target cell list in case of any other handover request
due to Power Budget. The O&M flag Enable_No_Back_HO is used to enable/disable this feature. Back handovers due to imperative criteria are not affected by this mechanism. Parameters for Back Handover Prevention Specification Name Enable_No_Back_HO Timer_Inhibit_Back_HO TIMER_FORCED_HO Object HAND ADJC ADJC DB Name NOBAKHO TINHBAKHO TIMERFHO Range TRUE/FALSE 1 .. 254 (30) 0300 (12) Step Size 1 1 Unit 1 sec 10sec
TINHBACKHO defines the time how long a power budget back handover is prohibited to a cell just left with an Imperative Handover. TIMERFHO defines the time how long a power budget back handover is prohibited to a cell just left with an Forced Handover (refer to section Directed retry).
64
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Power Budget HO
TINBACKHO
Fig. 17 Prevention of power budget back handover for time TINHBAKHO
MN1789EU11MN_0001
2005 Siemens AG
65
Siemens
3.4.4.1
To prevent handover repetition after consecutive HO failures to the same cell a Handover Failure Indication message is received from the BSC. A timer is started and until expiry of the timer the defined cell is excluded from the target cell list for any kind of handover. The penalization time is defined by the O&M parameter Timer_Inhibit_Failure_HO, the number of permitted HO failures is defined by the O&M parameter Max_Failure_HO. The O&M flag Enable_No_Failure_Rep_HO is used to enable/disable this feature. Parameters for Prevention of Handover Failure Repetition Specification Name Object DB Name Range Step Size 1 1 Unit 1 sec
Enable_No_Failure_Rep_HO HAND NOFREPHO TRUE/FALSE Max_Failure_HO Timer_Inhibit_Failure_HO HAND MAXFAILHO ADJC TINHFAIHO 1 .. 15 (2) 1 .. 254 (7)
The following configuration rule should be regarded: TINHFAIHO (BTS timer) > THORQST (BTS timer) > T7 (BSC timer). This condition allows the possibility to perform the handover towards the second cell indicated in the target cell list.
66
MN1789EU11MN_0001
2005 Siemens AG
Siemens
BTS
BSC
Cell A
HO Cond Ind (B, C, D) HO Failure (cell B) HO Cond Ind (B, C, D) HO Failure Ind (B) HO Failure (cell B) after MAXFAILHO consecutive HO failures on the same adjacent cells
1 2 3 4 CELL A CELL B
... MAXFAILHO
TINFAILHO
MN1789EU11MN_0001
2005 Siemens AG
67
Siemens
3.5
Generation of the Target Cell List The target cell list is generated by the BTS when a handover cause is detected. This list contains possible HO candidates i.e. neighbor cause to where the call can be handed over. The maximum number of cells to be included in the target cell list is given by the parameter N_CELL (Parameter NCELL in object HAND, Range: 0 ... 15).
Conditions for Neighbor Cells to be included in the Target Cell List Only those neighbor cells are included in the target cell list which fulfill the following conditions:
68
MN1789EU11MN_0001
2005 Siemens AG
Siemens
BTS
BSC
MSC
Handover Detection
yes HO Cond Ind - cause - target cell list no next cell available yes
Handover Failure
yes
Channel Activation
yes
MN1789EU11MN_0001
2005 Siemens AG
69
Siemens
Intracell Handover:
HO Condition Indication message with cause Intracell HO without target cell list is sent from the BTS to the BSC. BSC selects new channel for the call within the same BTS.
Intercell Handover:
HO Condition Indication message with cause and target cell list is sent from the BTS to the BSC. If the first cell within the target cell list is within its BSS area, the BSC selects a channel at the corresponding BTS. If no channel is available at that BTS, the next cell within the target cell is tried. If the first target cell (or the ones tried in further steps) does not belong to the own BSS area, a Handover Required message is sent to the MSC. This message contains a reduced target cell list (without the cells tried internally). This is illustrated in the figure above:
70
MN1789EU11MN_0001
2005 Siemens AG
Siemens
3.6
MS
HO Request Ack
HO Command
HO Access HO Access
HO Required
T3124
HO Complete
NY1
HO Required HO Failure
MN1789EU11MN_0001
2005 Siemens AG
71
Siemens
Parameter and Timer for Handover Signaling T_HAND_REQ Object HAND DB Name THORQST Range 0...31 (5) Purpose: Start: Stop: minimum time for HANDOVER CONDITION INDICATION messages for the same connection sending of HANDOVER CONDITION INDICATION by BTS Step Size 1 Unit 2 * SACCH multiframe
HANDOVER COMMAND received reason for handover has disappeared communication with MS is lost transaction has ended, call cleared
DB Name BSCT7
Step Size 1
minimum time for HANDOVER REQUIRED messages for the same connection sending of HANDOVER REQUIRED by BSC
HANDOVER COMMAND received reason for handover has disappeared communication with MS is lost transaction has ended, call cleared
Action expiry:
72
MN1789EU11MN_0001
2005 Siemens AG
Siemens
T8 Object BSC DB Name BSCT8 Range unit * 0...255 (HLFSEC-10) Step Size 1 Unit MS100 = 100 msec HLFSEC = 0.5 sec SEC5 = 5 sec
keep the old channel sufficient long to be able to return to it, and to release the channels if the MS is lost reception of HANDOVER COMMAND at BSC reception of CLEAR COMMAND from MSC or HANDOVER FAILURE from MS at BTS release of old channels
T3124 - MS Timer, not adjustable by parameter Purpose: Start: Stop: Action expiry: Default: detect the lack of answer from the network at handover access. sending of first HANDOVER ACCESS by MS reception of PHYSICAL INFORMATION by MS deactivation of new channel, reactivation of old channel, send HANDOVER FAILURE 675 msec for SDCCH - 320 msec else
MN1789EU11MN_0001
2005 Siemens AG
73
Siemens
T3105 Object BTS DB Name T3105 Range unit * 0...255 (MS10-10) Purpose: Start: Stop: Action expiry: period for repetition of PHYSICAL INFORMATION sending of PHYSICAL INFORMATION by BTS reception of correctly decoded signaling or TCH frame on new channel from MS at BTS repetition of PHYSICAL INFORMATION; if the maximum number of repetitions has been reached: release of new channel Step Size 1 Unit MS10 = 10 msec
NY1 Object BTS DB Name NY1 Range 0...254 (50) NY1 is the maximum number of repetitions of the physical information by the BTS. Step Size 1 Unit -
HOSYNC Object BSC DB Name HOSYNC Range NONSYNC/SYNC Step Size Unit -
Purpose: finely synchronized Handover (GSM 04.08) The finely synchronized handover is restricted to internal BTSE handover. In this case the MS only sends four HANDOVER ACCESS bursts (continuously in case of non-synchronized handover). Furthermore no PHYSICAL INFORMATIO is sent. The synchronized handover improves the speech quality during handover by a shorter handover procedure at the air interface.
74
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Handover types
MN1789EU11MN_0001
2005 Siemens AG
75
Siemens
4.1
4.1.1
In areas of critical radio conditions, situations might occur in which a call drops because of long handover decision time. In case of an uplink level loss shorter than 3s the normal handover triggering with averaging windows (>4s) is too slow. A moving mobile will be lost at the cell boundary or in the shadowed areas. Fast Uplink Handover offers a high speed handover to prevent from rapid uplink level loss, thus saving connections in special places with call drop problems, where the power level of a mobile decreases rapidly. The handover can be performed to a predefined cell to save the connection. The BTS maintains a Fast Uplink Handover specific bookkeeping list for each possible adjacent cell (up to 32) in which the neighbor cell measurements of the mobile, the downlink RXLEV (RXLEV of serving cell measured by the mobile) and the BTS transmit power are compiled and averaged. This bookkeeping list is the basis for generation and sorting of the target cell list. As said above the A_PBGT_HO window size (by default approx. 7.7 s) is not suitable to reflect the current situation related to the event 'Fast Uplink Handover' because it is too long. When a Fast Uplink HO (RXLEVUL<THLEVFULHO) is detected by evaluating the UL measurements (e.g. during the last second), a target cell has to be found that was good during that time (last second) and not during the last 7.7 seconds (during which the measurements of the A_PBGT_HO were averaged). Thus, a separate average must be calculated for the Fast Uplink HO, which is based on the window-size for the Fast Uplink HO on the received UL-level. The window-size in the Fast Uplink HO's bookkeeping list is one size smaller than that of the Fast Uplink HO averaging window.
76
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Arrival of SACCH report containing a flag indicating if the MS used DTX burst of a SACCH report (4 bursts make up on SACCH)
n+1
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
77
Siemens
Generation of the target cell list As a candidate for the target cell list, the minimum condition enhanced by an additional fast up link handover offset applies for the neighboring cell n: RXLEV_NCELL(n) > RXLEVMIN(n) + max(0; Pa) + FULRXLVMOFF; where Pa = MSTXPMAX(n) P MSTXPMAX(n) - maximum RF transmission power that a mobile station is permitted to use on a traffic channel in an adjacent cell. P- maximum transmission power capabilities of the mobile station.
Order Criterion for Fast Uplink HO Candidate Cells within the Target Cell List The target cell list is sorted into two sections, the first (high priority) section contains cells marked as predefined cells that have the attribute FastULHOCell (FULHOC) set to TRUE. The second section contains cells that are not predefined cells:
Both sections are sorted in decreasing order by the power budget PBGT of the neighboring cells, i.e. the cell with the lowest value of PBGT is ranked last. Prevention of a FUHO The FUHO is not detected
until the averaging window is full (end of measurements) as long as the timer for handovers is running (another handover has been
triggered and is pending)
78
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Database parameters DB Name EFULHO Object HAND Range TRUE, FALSE (default) THLEVFULHO HAND Description Flag used to enable/disable the FUHO. (Note: also internal intercell HO must be enabled, parameter INTERCH)
0 (< -110 dBm)... FUHO is possible when (FUHO 63 (> -48 dBm), average) RXLEVUL decreases below (8) THLEVFULHO. aLevFuHo=1-31 (1 SACCH multiframe step size, default: 2) wLevFuHo=1-3 (step size 1, default: 1) Averaging parameters used for FUHO signal strength measurements. aLevFuHo gives averaging window size (smaller than normal window size), wLevFuHo indicates weighting factor for "full" measurements (optional) When searching for FUHO target cells, cells with attribute FULHOC "TRUE" are preferred to cells with FULHOC "FALSE"
ALEVFULHO
HAND
FULHOC
ADJC
FULRXLVMOFF ADJC
RX level necessary for a neighbor cell to be included in the FUHO target cell step size 1 dB, where 0=-63 dB, list. 126=63 dB, (default 69=6 dB)
0, ... , 126
MN1789EU11MN_0001
2005 Siemens AG
79
Siemens
4.1.2
"Level Handover Margin" Parameters provide a new target cell criteria that takes the different requirements for level handover and quality handover into consideration. The creation of the target cell list is based on these new criteria.
4.1.2.1
To guarantee that a Level HO will be performed to a cell with higher level than that from serving cell the additional level handover margin (parameter LEVHOM) condition should be satisfied. In general a positive value should be chosen for this parameter but for special applications it is possible to choose a negative value to force a HO even in case of lower level in the target cell. HO procedure When the handover detection algorithm evaluates a handover condition, a target cell list is generated, i.e. a list of all adjacent cells which are considered as handover candidates. To guarantee that a level handover will be performed to a cell with a higher level than that of the serving cell, the candidate cell will now be included in the target cell list if additionally to the previously used condition RXLEV_NCELL(n) > RXLEV_MIN(n) + max (0,MS_TXPWR_MAX-P) also condition PBGT(n) > LEVHOM(n) is fulfilled. The operator on a cell basis can define this LEVHOM. The implementation of both conditions offers the operator the choice to prevent level handover below a certain level that the operator defines as not suitable for handover by setting RXLEVMIN. This new algorithm is very flexible since the operator still has the possibility to decide that RXLEVMIN does not impact the level handover by setting it to a low level.
80
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Database Parameters The operator has the possibility to enable or disable this feature. If this feature is disabled, the traditional condition RXLEV_NCELL(n) > RXLEV_MIN(n) + max(0,MS_TXPWR_MAX-P) is chosen. Object HAND DB Name ELEVHOM Range (Default) TRUE/ FALSE (FALSE) ADJC LEVHOM 0...126, steps of 1 dB. 0 = - 63 dB, 126 = + 63 dB (69= 6 dB) Only if the power budget of neighbor cells is higher than Level HO margin these neighbor cells will be included in the target cell list (if ELEVHOM=TRUE). Description Flag to enable or disable "Level Handover Margin".
MN1789EU11MN_0001
2005 Siemens AG
81
Siemens
4.1.2.2
The single use of the minimum level criteria for the target cell may not guarantee in all cases a sufficient signal level to maintain the connection after HO. To guarantee a target cell with a higher level than the serving cell an additional condition "Quality handover condition" is introduced. Neighbor cell is regarded as a suitable target cell and is thus inserted into the target cell list if it fulfills: RXLEV_NCELL(n) > RXLEV_MIN(n) + max (0, MS_TXPWR_MAX-P) (handover minimum condition) and RXLEV_NCELL(n) > RXLEV_DL + QUALLEVHOM(n) (additional condition).
It results the target cell receive level is, in case of both conditions fulfilled, better than the serving cell. So the number of unsuccessful handovers, back handovers or ping pong HOs can be reduced, less calls are dropped. Target Cell List Generation In order to evaluate the additional condition and to include in the Target Cell List cells that fulfill both criteria, the feature has to be enabled (SET HAND: ENAQUALEVHOM = 1, means TRUE).
82
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Database Parameters The operator has the possibility to enable or disable this feature. If this feature is disabled, the traditional solution RXLEV_NCELL(n) > RXLEV_MIN(n) + max(0, MS_TXPWR_MAX-P) is chosen. Object HAND DB Name Range (Default) Description
ENAQUALEVHOM 1 - TRUE/
The attribute indicates whether the "Level 0 - FALSE HO Margin for Quality HO" is enabled or disabled (FALSE) The parameter defines the margin by which the DL power level of a target cell in dB. shell exceed the DL power level of the 0 = - 63dB, serving cell to be entered into the target 126 = + 63 cell list in case of a quality HO dB (69= 6 dB) 0...126,
ADJC
QUALLEVHOM
MN1789EU11MN_0001
2005 Siemens AG
83
Siemens
4.2
EFR
Compression/Decompression HO Improvements
The feature Compression/Decompression Handover (HO) Improvements is realizing intracell handover between the following Codecs: GSM HR GSM HR
GSM FR
The Compression/Decompression of AMR calls (AMRFR AMRHR, i.e. handover between AMR Codecs) has been realized since release BR6.0 and was enhanced in BR7.0 by taking into account not only quality but also level conditions. This new feature impacts the existing AMR Compression/Decompression HO in sense that system has to decide which call to hand over in the case of cell load dependent conditions. It provides the selection of the best suited connection for compression HO out of all allocated calls (AMR calls as well as connections using standard codecs).Therefore some parameters introduced specify in addition whether AMR mobiles should be included in the algorithm while the parameters concerning AMR thresholds will be given in the AMR HO section 4.5.3. For Compression HO the BTS keeps the following:
A list of connections for which condition for compression is fulfilled (exceeded C/I
thresholds for compression, i.e. HOTHxxCMPyy, where xx specifies EFR or FR, and yy DL or UL direction) or/and EADVCMPHOSC and ADVCMPHOOAMR to specify the codec specific preference) the highest C/I).
determination of the best suited connection from the candidate list (connection with
traffic load dependent triggering of decompression HO (FRACTTH and due to relaxing traffic load ongoing connections can be shifted from half-rate mode connection that is closest its decompression threshold is selected
(HRDCMLIMTH).
84
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Database Parameters
DB Name Object Range Description
HOTHEFRCMPDL
HAND
0, 1, 30 dB (18 dB)
This parameter specifies a C/I threshold for compression handover from EFR to GSM HR in downlink This parameter specifies a C/I threshold for compression handover from EFR to GSM HR in uplink This parameter specifies a C/I threshold for compression handover from FR to GSM HR in downlink This parameter specifies a C/I threshold for compression handover from FR to GSM HR in uplink This parameter specifies a C/I threshold for decompression handover from GSM HR to EFR respectively to GSM FR in downlink. This parameter specifies a C/I threshold for decompression handover from GSM HR to EFR respectively to GSM FR in uplink. .
HOTHEFRCMPUL
HAND
0, 1, 30 dB (18 dB)
HOTHFRCMPDL
HAND
0, 1, 30 dB (18 dB)
HOTHFRCMPUL
HAND
0, 1, 30 dB (18 dB)
HOTHHRDCMDL
HAND
0, 1, 30 dB (13 dB)
HOTHHRDUL
HAND
0, 1, 30 dB (13 dB)
EADVCMPHOAMR
HAND
This parameter specifies if AMR HR capable mobiles are selected as candidates for compression handover This parameter specifies if GSM HR capable mobiles are selected as candidates for compression handover
EADVCMPHOSC
HAND
MN1789EU11MN_0001
2005 Siemens AG
85
Siemens
DB Name
Object
Range
Description
ADVCMPHOOAMR
HAND
This parameter specifies the codec specific preference (offset of AMR compared to standard codecs)
HRDCMLIMTH
HAND
0100 dB (6 dB)
Threshold for limitation of load dependent decompression HO. Connection that are not far than this threshold to decompression threshold are selected Load dependent threshold for decompression handover for standard cells or complete area of concentric cell, far area of extended call for standard codecs
FRACTTH1
BTS
0, 1, , 10000 (3000)
FRACTTH2
BTS
0, 1, , 10000 (3000)
Load dependent threshold for decompression handover for inner area of concentric cell, near area of extended call for standard codecs Load dependent threshold for decompression handover for standard cells or complete area of concentric cell, far area of extended call for AMR calls Load dependent threshold for decompression handover for inner area of concentric cell, near area of extended call for AMR calls
FRACTAMRTH1
BTS
0, 1, , 10000 (3000)
FRACTAMRT2
BTS
0, 1, , 10000 (3000)
advComprHoOffsetAMR > 0 preferred AMR mobiles for compression HO advComprHoOffsetAMR < 0 preferred mobiles using standard codecs for
compression HO
86
MN1789EU11MN_0001
2005 Siemens AG
Siemens
4.3
MN1789EU11MN_0001
2005 Siemens AG
87
Siemens
4.3.1
Maximum propagation delay within one timeslot allows a maximum BS-MS distance of 35 km. In extended cells the operator can configure TCHs optionally as double timeslot channels where two subsequent timeslots are used for transmission to provide coverage further than 35km. Extended Cell Handover is the intracell handover between a single timeslot channel and a double timeslot channel and vice versa. Handover detection is based on comparison of actual BS-MS distance with a threshold (O&M parameter). Extended Cell handover can be enabled/disabled via O&M flag ENABLE_EXTENDED_CELL_HO' only if there are double and single timeslots configured in the cell ( CHANTYPE=EXTMODE). Parameters for Extended Cell Handover Specification Name Object DB Name EXTCHO HOMSTAM HOMRGTA Range TRUE/FALS E 0 .. 34 (32) HO_MARGIN_TA HAND 0 .. 35 (4) HO_TH_MS_RANGE_MAX_EXT HAND HOTMSRME 35100 (99) A single-to-double timeslot handover is detected when the actual BS-MS distance exceeds the threshold HO_MS_TA_MAX (handover alarm distance_near_far); a double-to-single timeslot handover is detected when the actual BS-MS distance falls below the threshold minus a hysteresis factor HO_MARGIN_TA (handover alarm distance_far_near). The following additional condition must be fulfilled for a single to double timeslot handover: 1 km Step Unit Size 1 km
> HO_MS_TA_MAX
or the following additional condition must be fulfilled for a double to single timeslot handover:
(no double to single timeslot HO will be performed in case of HOMSTAM HOMRGTA < 0).
88
MN1789EU11MN_0001
2005 Siemens AG
Siemens
BCCH double
TCH double
TCH double
TCH single
TCH single
HOMRGTA
Distance
MS - BTSE
HOMSTAM
HOTMSRME
MN1789EU11MN_0001
2005 Siemens AG
89
Siemens
4.3.2
4.3.2.1
Cell configurations
Introduction on concentric cell
The term Concentric Cell means two logical cells within one GSM/DCS cell: Inner area and complete area. The TX power of the TRXs belonging to the inner area is strongly reduced, which results in a lower radius. This feature can be used to introduce an additional frequency re-use pattern for the frequencies in the inner area, i.e. a frequency re-use pattern can be used with a shorter re-use distance. This will increase the network capacity without appreciable increase of interference. A flag is used to define whether the cell is a concentric one or not. Furthermore it has to be specified per TRX whether this TRX should belong to the inner area or to the complete area. One set of signaling channels -BCCH & SDCCH- in the complete area is used by MSs camping in both areas. Intracell handovers between the two areas depend on field strength level and the location of the mobile. These handovers are executed on level / distance conditions defined by appropriate thresholds in the handover package. Moreover, during the call setup procedure in a concentric cell the same values are also evaluated to determine whether the call is set up on a TCH belonging to an inner or complete area TRX. Possible intracell handovers:
From complete area to inner area of a concentric cell From inner area to complete area of a concentric cell.
Possible intercell handovers:
From complete area of concentric cell A to complete area of concentric cell B From complete area of concentric cell A to inner area of concentric cell B From inner area of concentric cell A to complete area of concentric cell B From inner area of concentric cell A to inner area of concentric cell B only for
sectorized concentric cells, i.e. both concentric cells are served by the same BTSE.
90
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Complete Area
Inner Area
Fig. 26 Inner and complete area of two adjacent concentric cells A and B
MN1789EU11MN_0001
2005 Siemens AG
91
Siemens
4.3.2.2
Dual band operation network offers the possibility to establish the GSM service in two different GSM specified frequency bands (i.e. GSM900 and GSM1800 or GSM850 and GSM1900). Therefore the operation of "dual band" MS is supported in such network as well as the handover between cells or cell areas belonging to different bands. The transceiver equipment for frequency bands can be implemented in one BTSE (site). The operator has several configuration possibilities when configure cells in a site:
to configure each cell working in a single and different frequency bands (BCCH
and BSIC have to be planned for each cell),
to configure cells each working in both frequency bands with common BCCH using
concentric cell approach (so called Common BCCH Dual Band Cell), standard cell approach (so called Dual Band Standard Cell).
to configure cells each working in both frequency bands with common BCCH using
Up to BR7.0, the common BCCH implementation is based on the concentric cell approach. One frequency band covers the inner area, while the other covers the complete area. The common BCCH (also SDCCH) always belongs to the frequency band of the complete area. This type of cell configuration makes planning easier as Common BCCH Dual Band cell has cell identity as single band cell. The disadvantages of this cell structure are:
increased load due to introducing the specific intra-cell handover from inner to
complete area and vice versa (propagation difference between two bands and different power classes of the MS have to be considered and call set up level conditions are evaluated to determine whether the call is set up on TCH in inner or complete area),
incoming handover only possible to the complete area (exception collocated cells), GPRS/EGPRS support restricted only to the BCCH band, DMA not supported.
With BR8.0 a Dual Band Standard Cell (or Common BCCH Standard Cell) is introduced as a new type of cell architecture.
92
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Concentric Cell
F3 GSM 900
F2 GSM 900
F4 (GSM 900)
Dual Band Standard Cell
F1 (GSM 1800)
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
93
Siemens
The Dual Band Standard cell must be planned so that the two frequency bands have well matched cell boundaries, i.e. overlapping coverage. In that case a service can be allocated on either one of the frequency bands independent of its location in the dual band standard cell. This feature can support the entire range of applicable frequency band combinations, i.e. 900/1800, 850/1800 and 850/1900 MHz. The choice of the frequency band for the allocation of the BCCH is not restricted. Another characteristics are:
GPRS/EGPRS can be allocated in both frequency bands, no load balancing is present, radio resources allocation is performed according to the feature improvement of
Multi-layer service support,
BCCH can belong to any frequency band, two DMA layers per cell can be configured.
Database parameters for cell configuration: DB Name CELLTYP Object BTS Range STDCELL, EXTCELL, DBSTDCELL SYSID BTS/ TGTBTS BB900, GSMR, DSC1800, EXT900, PCS1900, GSM850, GSMDCS, GSM850PSC, GSM850DCS TRUE/ FALSE Meaning Specifies a cell type: standard cell with max MS distance 35km, extended cell with max Ma distance 100km, dual band standard cell Specifies frequency band/bands supported by the cell. The attribute CELLTYP can not assume value DBSTDCELL with SYSID different than GSMDCS, GSM850PCS, GSM850DCS
Flag indicates whether concentric cell configuration is used or not Static reduction of TRX output power: BS_TXPWR_MAX = PBTS - 2 * PWRRED unit: 2 dB Specifies the area the TRX belongs to a concentric cell, and if so which area it serves. For DBSTDCELL TRXAREA must be set to NONE. Specifies availability of GPRS/EGPRS: only on BCCH (NULL), on 900MHz frequencies (ALL900), or all frequencies
PWRRED 0...6
TRXAREA TRX
GRXT
BTS
94
MN1789EU11MN_0001
2005 Siemens AG
Siemens
4.3.3
4.3.3.1
Database Parameters for Single Band Concentric Cell handover EN_CON_CELL_DIST Object HAND DB Name CCDIST Range TRUE/ FALSE Step Size Unit
This is the flag to enable/disable the impact of a distance on the intracell handover decision in addition to the HORXLVDLI / HORXLVDLO condition within the concentric cell intracell handover algorithm.
HO_RXLEV_DL_INNER Object HAND DB Name HORXLVDLI Range 0...63 (26) Step Size 1 Unit 1 dB
This attribute defines the receive signal strength threshold on downlink which is evaluated for the intracell handover from a TRX belonging to the inner area to a TRX belonging to the complete area of a concentric cell. The condition, which must be fulfilled to perform an intracell handover from inner- to complete area, is: RXLEV_DL(serv. cell) < HORXLVDLI The RXLEV_DL(serv. cell) is the averaged value derived from the handover measurement preprocessing.
MN1789EU11MN_0001
2005 Siemens AG
95
Siemens
HO_RXLEV_DL_OUTER Object HAND DB Name HORXLVDLO Range 0...63 (32) Step Size 1 Unit 1 dB
This attribute defines the receive signal threshold level on downlink which is evaluated for the intracell handover from a TRX belonging to the complete area to a TRX belonging to the inner area of a concentric cell, furthermore the TCH assignment is influenced by this threshold. The condition, which must be fulfilled, to perform an intracell handover from complete- to inner area, or to assign a TCH directly in the inner area is: RXLEV_DL(serv. cell) > HORXLVDLO
HO_CON_CELL_DIST Object HAND DB Name HOCCDIST Range 0...35 (5) Step Size 1 Unit 1 Km
This attribute specifies the distance limit between inner and complete area of a concentric cell which is taken into account for the intracell handover in addition to the attribute hoRxlevDinner, respectively hoRxLevDlouter. The condition, which must be fulfilled to perform an intracell handover from inner to complete area, is: RXLEV_DL(serv. cell) < HORXLVDLI or BS_MS_DIST > HOCCDIST (if CCDIST=TRUE) The condition, which must be fulfilled, to perform an intracell handover from complete- to inner area, or to assign a TCH directly in the inner area is: RXLEV_DL(serv. cell) > HORXLVDLO and BS_MS_DIST < HOCCDIST (if CCDIST=TRUE) To avoid handover oscillation between inner and complete area, the following recommendations have to be considered: HORXLVDLO > HORXLVDLI and HORXLVDLO - HORXLVDLI > BS_TXPWR_MAX(Complete) - BS_TXPWR_MAX(Inner)
96
MN1789EU11MN_0001
2005 Siemens AG
Siemens
HORXVLO
HOCCDIST
HORXLVDLI
Complete Area
CCELL1
Serving cell
Inner Area
CCELL2
MN1789EU11MN_0001
2005 Siemens AG
97
Siemens
4.3.3.2
In sectorized concentric cells inner to inner area handover is possible. COLOCATED_CELL Object HAND DB Name CCELL1, CCELL2 Range pathname, e.g. BTSM:0/BTS:2 Step Size Unit BTS ID
The attribute defines the cells belonging to the sectorized concentric cells for which it is possible to perform an intercell handover into the inner area. Collocated cell1 defines the first of two possible adjacent sectorized concentric cells to which an intercell HO from inner to inner area shall be possible. EN_INNER_INNER_HO Object HAND DB Name ININHO Range TRUE/ FALSE Step Size Unit
Flag to enable/disable the intercell handover from inner to inner area in sectorized concentric cells. Under normal conditions (with ININHO=FALSE) the incoming handover would be executed to the complete area of the collocated cell first, after that a complete-to-inner handover would follow. The condition, which must be fulfilled to perform an intercell handover into the inner area of a collocated neighbor cell, is: RXLEV_NCELL(adj. cell) > HORXLVDLO(n) and BS_MS_DIST < HOCCDIST(n) (if CCDIST(n)=TRUE). In this case the BSC sends a message PREFERRED AREA REQUEST to the serving BTS together with the relevant parameters of the target cell. The BTS calculates whether a intercell handover directly into the inner area is possible or not. The BSC is informed with message PREFERRED AREA and assigns an appropriate TCH.
98
MN1789EU11MN_0001
2005 Siemens AG
Siemens
4.3.3.3
In order to optimize signal reception within the concentric cell the Common BCCH Dual Band cell selects an intracell handover from the complete area (i.e. GSM900) to the inner area (i.e. GSM1800), or vice versa. In a single-band concentric cell the intracell HO decision is made by analyzing the downlink received level and, if applied, the measured MS-BS distance. Uplink conditions are not important because the mobile is not affected when the call is handed over between the two areas inside the cell. In contrast to this, in a dual-band concentric cell when the mobile is moved from the GSM area to the DCS one or vice versa, the uplink conditions change due to the fact that the mobile has different power classes in the two bands. Therefore the algorithm for intracell HO in a dual band cell from complete to inner area is extended as follows: RXLEV_DL(serv. cell) > HORXLVDLO + Max [ 0, MS_TXPWR_MAX(inner) - P(inner) ] A cell using frequencies from different bands must be configured with different parameters to define the maximum allowed MS transmit power per band.
MN1789EU11MN_0001
2005 Siemens AG
99
Siemens
4.3.4
Directed retry
Directed retry is the transition (handover) from a SDCCH in one cell to a TCH in another cell during call setup because of unavailability of an empty TCH within the first cell. Directed retry is a means to control the traffic distribution between cells and to avoid a call rejection because of congestion in one cell. If Queuing of ASS REQs is not supported within a BSC Directed retry is merely triggered by the BSC by sending a Forced HO Request message to the BTS, which has to respond with an "initiated" Intercell HO Cond. Indic. message. It can happen that the Intercell HO Cond. Indic. message does contain only an empty target cell list (If triggered by a Forced HO Request message the BTS has to send a Intercell HO Cond. Indic. message even if no suitable neighbor cell exists - in this case the target cell list is empty!). In this case a TCH cannot be assigned and the BSC shall not send a HO RQD message to the MSC of course but shall send an ASS FAILURE (cause "no radio resource available"). If the target cell list contains cells from inside and outside the BSC area and if e.g. the first and second cell is inside, the third outside and the fourth inside the BSC area than the Directed retry attempts shall be carried out as BSC controlled Directed retries to the first and second one. If these Directed retries are not possible for any reason (e.g. no empty TCH) than the third attempt and all following attempts (independently whether the fourth and the following cells lie in- or outside the BSC area) shall be executed as MSC controlled directed retry. If in case of a MSC controlled handover the MS cannot access the new cell and the MSC receives a HO FAILURE (cause "radio interface failure, reversion to old channel") from the old BSS, it can happen that the MSC generally releases this SDCCH connection by sending a CLEAR CMD message (cause "radio interface failure, reversion to old channel") to the BSC independently. If the MSC does not support Directed retry HOs the BSC may perform BSC controlled Directed retries (approximately 75% of all Directed retries) only. In this case the EN_INTER_SDCCH_HO flag in the BSC shall be set to "disabled" and the BSC has to check the target cell list of Intercell HO_Cond_Ind messages belonging to a SDCCH connection. All cell identifiers not belonging to the BSC area shall be skipped and if there remain cell identifiers belonging to the BSC area the corresponding HO shall be performed to strongest (if impossible to the second strongest, third strongest etc.) remaining cell. If the target cell list does not contain a remaining or any cell identifier of the same BSC area, this Intercell HO Cond. Indic. message shall be discarded and the BSC shall release this SDCCH connection (Sending of an ASS FAILURE with cause "no radio resource available").
100
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Is the incoming message an Assignment_REQ ? Y BSC sends to BTS Forced_HO_Request BTS sends to BSC Intercell_HO_Cond_Ind with target cell list Suiteble cell in list ? Y BSC assigns TCH internally and sends Assignmend_Complete to MSC Y Cell within BSC area ? N N
EN_INTER_SDCCH_HO set to enable ? Y Assign TCH Y Directed Retry towards MSC successful ?
MN1789EU11MN_0001
2005 Siemens AG
101
Siemens
HO Algorithm and Generation of the Target Cell List The BTS has to send the Intercell HO Cond. Indic. messages toward the BSC. Please note that for Directed retry the sending of an Intercell HO Cond. Indic. message for a SDCCH may only be triggered by a BTS external event: The BSC sends a Forced HO Request because of "no TCH available". If an Intercell HO Cond. Indic. message is to be sent, the target cell list shall contain all neighbor cells with: RXLEV > RXLEV_MIN + Max(0, MS_TXPWR_MAX-P) + FHO_RXLEV_MIN_OFFSET The ranking of the neighbor cells in the target cell list is performed in the order of decreasing values of: PBGT - HO_MARGIN <=> 0. Additional parameters specific to speed sensitive HO shall be taken into account for the ranking of the target cells. Even if no suitable neighbor cell exists, the BTS shall send an Intercell HO Cond. Indic. message. In this case the target cell list ("Cell Identif. List Pref. IE") shall be empty! The cause of the Intercell HO Cond. Indic. message shall be FORCED. FHO_RXLEV_MIN_OFFSET is a cell specific O&M-parameter to select only target cells for forced HO which the MS can access without any problems. It is a result of radio planning for each individual cell. It allows to influence the amount of Forced HOs failed because of empty target cell list, the amount of HO attempts back to the "old" cell and the success rate of HO ACCESSes to the target cell.
Prevention of Power Budget Back-Handovers A major general problem of forced HO (Directed retry is one sort of forced HO!) is the probability of HO due to PBGT back to the "old" (congested) cell. Its drawbacks are: 1. increased load at the Abis-interface because of periodic sending of Intercell HO_Cond_Ind messages in intervals of T7 2. increased load at the A-interface in case of inter-BSC-HO because of the same reason 3. additional processor capacity in BSC (and MSC) is required for HO trials for which it is known in advance that they are useless 4. the load in the congested cell will not be reduced for a certain time, but it will be kept at a permanent high level.
102
MN1789EU11MN_0001
2005 Siemens AG
Siemens
For the Channel Activation message a new optional information element "Cell Identifier List (no target)" is defined. This information element contains the cell identifier (CI) of a cell from which a handover request (intra- or inter-BSC) because of forced HO was received. If this information element exists in the Channel Activation message, the BTS
shall not trigger a (TCH-)HO due to PBGT for the time Tbho if the PBGT condition
is fulfilled for the indicated cell only and
shall not include the indicated CIs in the target cell list in this case for the time
Tbho (i.e. for the condition HO due QUAL/LEV/DIST the indicated cell identifier may be part of the target cell list).
Tbho is a timer that limits the mentioned prohibitions. It has to be set by O&M command. If a HO is necessary the target BSC has to generate the Channel Activation message. The target BSC shall insert the Cell Identifier List (no target) IE into this message. The BSC shall derive the CI for the Cell Identifier List (no target) IE from the stored context in case of intra BSC HO or from the mandatory Cell Identifier (serving) IE of the HO REQ message in case of inter BSC HO with cause "Directed retry".
MN1789EU11MN_0001
2005 Siemens AG
103
Siemens
Database Parameters for Directed Retry EN_FORCED_HO Object BSC DB Name ENFORCHO Range ENABLE DISABLE Step Size Unit -
This BSC specific O&M flag allows to enable/disable the sending of Forced HO Request messages for running SDCCH connections (e.g. queued or not queued ASS REQs which do not find an empty TCH). It is used to enable/disable Directed retry.
EN_INTER_SDCCH_HO Object BSC DB Name EISDCCHHO Range ENABLE DISABLE Step Size Unit -
This BSC specific O&M flag allows to enable/disable inter BSC SDCCH-HOs (i.e. SDCCH-SDCCH-HO and Directed retry). It simply prevents the sending of HO RQD messages for SDCCH connections to the MSC. This flag should be set to "disable" by an operator if in a network the MSC, which the BSS is connected to or other adjacent BSSs do not support the prevention of "back-HO". If it is set to "disable" the BSC shall skip all cell identifiers of the target cell list of the Intercell HO Cond. Ind. message, which belong to another BSC area. Tbho is a timer that limits the mentioned prohibitions. It has to be set by O&M command. If a HO is necessary the target BSC has to generate the Channel Activation message. The target BSC shall insert the Cell Identifier List (no target) IE into this message. The BSC shall derive the CI for the Cell Identifier List (no target) IE from the stored context in case of intra BSC HO or from the mandatory Cell Identifier (serving) IE of the HO REQ message in case of inter BSC HO with cause "Directed retry".
104
MN1789EU11MN_0001
2005 Siemens AG
Siemens
EN_FORCED_HO Object BSC DB Name ENFORCHO Range ENABLE DISABLE Step Size Unit -
This BSC specific O&M flag allows to enable/disable the sending of Forced HO Request messages for running SDCCH connections (e.g. queued or not queued ASS REQs which do not find an empty TCH). It is used to enable/disable Directed retry.
EN_INTER_SDCCH_HO Object BSC DB Name EISDCCHHO Range ENABLE DISABLE (DISABLE) This BSC specific O&M flag allows to enable/disable inter BSC SDCCH-HOs (i.e. SDCCH-SDCCH-HO and Directed retry). It simply prevents the sending of HO RQD messages for SDCCH connections to the MSC. This flag should be set to "disable" by an operator if in a network the MSC, which the BSS is connected to or other adjacent BSSs do not support the prevention of "back-HO". If it is set to "disable" the BSC shall skip all cell identifiers of the target cell list of the Intercell HO Cond. Ind. message, which belong to another BSC area. Step Size Unit -
FHO_RXLEV_MIN_OFFSET Object ADJC DB Name FHORLMO Range 0...24 (6) Step Size 1 Unit 1 dB
FHO_RXLEV_MIN_OFFSET ("RXLEV_MIN offset for forced-handover") is a cell specific O&M-parameter used within the BTS to select only target cells for forced HO which the MS can access without any problems. It is a result of radio planning for each individual cell. It allows to influence the amount of Forced HOs failed because of empty target cell list, the amount of HO attempts back to the "old" cell and the success rate of HO ACCESSes to the target cell.
MN1789EU11MN_0001
2005 Siemens AG
105
Siemens
Tbho Object ADJC DB Name TIMERFHO Range 1...320 (12) Step Size 1 Unit 10 sec
Tbho (bho=back handover) is a neighbor cell specific O&M parameter. It is the value of a timer running in the BTS that controls the duration how long a former serving cell from which forced HO was performed to the new serving cell may not be considered in the PBGT HO decision algorithm of the new serving cell and may not be contained in the target cell list. It is started at the reception of a Channel Activation message containing a Cell Identifier (no target) IE.
4.3.5
HO decision due to BSS resource management criteria (HO due to traffic load)
The purpose of this feature is to increase the network efficiency by redistributing of traffic between the cells of a BSC area. The handover for traffic reason has been introduced in order to move calls from heavily loaded cells into adjacent cells with lower utilization. The expected benefit from this feature is to be able to free some channels in a high traffic cell in order to use the released channels for new calls. The Traffic cause is not foreseen on the A interface and the serving BSC cannot control the channel occupancy of a cell belonging to another BSC, consequently the handover for traffic reason may be performed only between cells belonging to the same BSC. This feature implementation can avoid the planning of new resources into a cell and the channel reservation for high traffic situation. The handover for traffic reason is the lowest priority one, because the technical necessary handovers shall be preceded first in order not to disturb the normal network behavior too much. The HO due to resource criteria is not triggered for extended cells. In concentric cells only the outer area is checked for the resource criteria. This feature as well as Directed Retry has the scope of increasing the capacity of the network. Whereas Directed Retry acts on new connections by moving them towards adjacent cells, HO Decision due to BSS Resource Management Criteria moves connected users towards adjacent cells allowing in the previously used cell new connections to be set up. A connection moved for Directed Retry can be far from the ideal cell border, while the connection moved by HO Decision due to BSS Resource Management Criteria is chosen near to the ideal cell border.
106
MN1789EU11MN_0001
2005 Siemens AG
Siemens
If the function is enabled in a cell (Traffic_Handover_Enable = TRUE), the following procedure is applied: 1. The BSC periodically (Traffic_Control_Timer) evaluates the traffic level for that cell. If the percentage becomes higher or equal a given threshold (Traffic_High_Threshold), the cell is regarded as a high traffic cell and the handover cause due to traffic is enabled. When this message is received by the BTS it starts timer TRFHOT and reduces the handover margin towards neighbor cells by one Margin Step Size. In the BTS two tasks (parent /dedicated) are implemented to proceed the evaluation of the handover due to BSS resource management criteria. In case of cause detection and evaluation of appropriate neighbor cell candidate(s), the BSC will be informed via Intercell_Handover_Cond_Ind message that includes the handover cause "traffic" together with the list of preferred target cells. 2. Otherwise the cell will be regarded as a low traffic cell and the handover cause due to traffic is disabled. In order to evaluate correctly the percentage of busy channels in case of FR- and HR-channels in use, the FR-channels are considered with weight 2 and the HRchannels with weight 1. If the handover cause due to traffic changes from disabled to enabled or vice versa, the BTS will be informed. 3. When receiving the message "Intercell_Handover_Cond_Ind" with cause "traffic", the BSC analyses the target cell list in order to discard all neighbor cells with a high traffic load where the percentage of busy channels is higher than a given threshold (Traffic_Low_Threshold).
Every time the timer TRFHOT expires the following procedure is started: 1. If the HO due to traffic reason is enabled the counter value m is increased by one up to a value which is not higher than Traffic_Margin_Max / Traffic_Margin_Step. If m has already reached this value m stays constant. In any case the timer is restarted. 2. If the HO due to traffic reasons is disabled the value m is decreased by one and the timer is restarted. If the value reaches 0 the timer is not started again.
MN1789EU11MN_0001
2005 Siemens AG
107
Siemens
The traffic HO condition is fulfilled if one or more internal adjacent cells are evaluated with a positive result according to the following algorithm: Case 1 - HCS disabled (HIERC = FALSE) RXLEV_NCELL(n) > RXLEV_MIN(n) + max[0, MS_TXPWR_MAX(n) - P] & PBGT(n) > TRAFFIC_HO_MARGIN(n) - K Case 2 - HCS enabled (HIERC = TRUE) RXLEV_NCELL(n) > RXLEV_MIN(n) + max[0, MS_TXPWR_MAX(n) - P] & PBGT(n) > TRAFFIC_HO_MARGIN(n) - K & (PLNC(n) = PL if parameter Traffic_Keep_Priority is set to TRUE or PLNC(n) PL if parameter Traffic_Keep_Priority is set to False) Where K = m * Traffic_Margin_Step with m = 1, 2, 3,.....,Traffic_Margin_Max / Traffic_Margin_Step
Back Handover Prevention in case of traffic HO Back-handover prevention is triggered by BSC by including the old cell and the handover cause (traffic) into the Channel activation message. A timer (Back_HO_Forbidden_Timer) is started in the BTS and until the timer for the originated cell expires, the back HO due to BSS resource criteria or due to power budget is inhibited.
108
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Traffic HO Evaluation
m>0
Y
End
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
109
Siemens
Parameters to control traffic HO in the BTS Specification Name Traffic_Control_Timer DB Name/ Object TRFCT / BSC Range 10...200 (20) Meaning unit = 0.5 sec This parameter establishes for each BTS the period of time to wait before evaluating the traffic level This parameter allows to enable/disable the handover for traffic reason feature in the BTS unit = % This parameter defines the high traffic level threshold in order to establish if the handover for traffic reason has to be enabled or disabled. unit = % This parameter defines the low traffic level threshold in order to establish if a cell can be a candidate to receive handover for traffic reason. unit = sec This parameter represents the timer which is used to establish the period of time to wait before updating the m value. The m value is increased if the traffic HO cause is enabled and decreased if the traffic HO cause is disabled, m is updated until it reaches value 0 unit = 1 dB This parameter establishes the minimum reduction for TRFHOM
Traffic_HO_Enable
TRFHOE / HAND
Traffic_High_Threshold
TRFHITH / HAND
Traffic_Low_Threshold
TRFLTH / HAND
0...85 (70)
Traffic_HO_Timer
TRFHOT / HAND
2...20 (10)
Traffic_Margin_Step
TRFMS
148 (9)
110
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Meaning unit = 1 dB This parameter establishes the maximum reduction for TRFHOM. This parameter determines whether candidate cells have to be of the same priority as the serving cell or may be of the same or higher priority unit = 1 dB (-63 dB .... +63 dB)
Traffic_Keep_Priority
TRFKPRI / HAND
TRUE FALSE
Traffic_HO_Margin
TRFHOM / ADJC
0...126
(67=4dB) This parameter defines the nominal cell border between cells for traffic handover reason 1...120 (30) unit = sec This parameter represents the timer used to establish the time for which a back handover due to traffic reason or PBGT (Power Budget) has to be avoid.
Back_HO_Forbidden Timer
BHOFOT / ADJC
MN1789EU11MN_0001
2005 Siemens AG
111
Siemens
4.4
The feature Service dependent Handover Management distinguishes fourteen service groups. This concerns Circuit-Switched services (CS) on Half Rate (HR), Full Rate (FR), Enhanced Full Rate (EFR), Adaptive Multi-Rate (AMR), Advanced Speech Call Items (ASCI), Voice Broadcast Services (VBS), Voice Group Call Services (VGCS), and High Speed Circuit-Switched Data services (HSCSD). For each service group relevant threshold parameters for handover can be defined individually. The different service groups are summarized in the table below: Service Group SG-1 SG-2 SG-3 SG-4 SG-5 SG-6 SG-7 SG-8 SG-9 SG-10 SG-11 SG-12 SG-13 SG-14 Description Signaling on hopping channel Signaling on non-hopping channel CS speech (FR, EFR, ASCI VBS, ASCI VGCS) on hopping channel CS speech (FR, EFR, ASCI VBS, ASCI VGCS) on non-hopping channel CS speech (HR) on hopping channel CS speech (HR) on non-hopping channel CS data up to 9,6kbit/s or HSCSD 9,6kbit/s on hopping channel CS data up to 9,6kbit/s or HSCSD 9,6kbit/s on non-hopping channel CS data up to 14,4kbit/s or HSCSD 14,4kbit/s on hopping channel CS data up to 14,4kbit/s or HSCSD 14,4kbit/s on non-hopping channel CS speech (AMR-FR) on hopping channel CS speech (AMR-FR) on non-hopping channel CS speech (AMR-HR) on hopping channel CS speech (AMR-HR) on non-hopping channel
If parameters are set for a specific service group, the system will use these values for the handover algorithm when applied on the ongoing service belonging to the service group, otherwise the global parameter settings are used.
112
MN1789EU11MN_0001
2005 Siemens AG
Siemens
HAND object
General settings for BSC area for all SGs that are not activated
HAND parameters: INTERCH INTRACH HOLTHLVDL HOLTHQUDL SG1HOPAR SG2HOPAR SG14HOPAR
Example: SET HAND: SG1HOPAR=10-10-35-35-26-32-5-5; Each field represents a specific parameter which is already known from the standard parameter's list. The meaning of these eight fields in the attribute SG1HOPAR are:
SG1HOPAR = 10 10 35 35 26 32 -
MN1789EU11MN_0001
2005 Siemens AG
113
Siemens
114
MN1789EU11MN_0001
2005 Siemens AG
Siemens
4.5
AMR-handover
The handover (and power control) decision for AMR calls is in principle the same as for 'normal' speech calls. The only exception is that for quality based decisions not the RXQUAL but the C/I is taken. Measured and reported RXQUAL values are mapped into the C/I values in the BTS.
4.5.1
Intercell HO downlink / uplink due to quality for an AMR call is triggered if the quality (C/I value) drops below the thresholds determined by the parameters 1. hoLowerThresQualAMRDL for downlink and 2. hoLowerThresQualAMRUL for uplink. The above parameters are relevant only if the intercell HO due to quality is enabled (RXQUALHO=TRUE). Parameter Object Range 0 ... 30 Unit=1 dB, (8 dB) Description hoLowerThresQualAMRDL Quality HO for DL is triggered if the DL quality (C/I) exceeds HOLTHQAMRDL. For good granularity a minimum averaging window size of 4 for averaging C/I is used for AMR calls. hoLowerThresQualAMRUL Quality HO for UL is triggered if the UL quality (C/I) exceeds the value HOLTHQAMRUL.
HOLTHQAMRDL HAND
HOLTHQAMRUL HAND
MN1789EU11MN_0001
2005 Siemens AG
115
Siemens
4.5.2
The purpose of the AMR compression HO is to transfer AMR FR calls with suitably good radio link quality to an AMR HR TCH in order to use the TCH resources more efficiently. The intracell AMR compression HO is not continuously enabled in the BTS but temporarily enabled/disabled by the BSC dependent on availability of radio channels and Abis resources. On every expiry of the timer TRFCT the BSC checks the traffic load in its cells and compares it to the threshold HRACTAMRT1 (or HRACTAMRT2) as illustrated in the figure below. The AMR HO from FR to HR is only enabled when the percentage of busy TCH is higher than these predefined thresholds. The purpose of the AMR decompression HO is to transfer AMR HR calls with poor radio link quality to an AMR FR TCH in order to improve speech quality. In contrast to AMR compression HO the AMR decompression HO is continuously enabled in the BTS disregarding the cell load, i.e. if at least one TCH/F is free, HO is performed. AMR compression/decompression HO is always performed in the BSC if the BSC parameter HRSPEECH is set to TRUE. The parameter EADVCMPDCMHO (Enable Advanced Compression/Decompression HO) just allows switching between standard and advanced mode of AMR Compression/Decompression HO.
4.5.2.1
Standard AMR compression/decompression HO (EADVCMPDCMHO=FALSE) decision is solely based on quality criteria defined by the parameters HOTHAMRCDL, HOTHAMRCUL, HOTHAMRDDL and HOTHAMRDUL. Standard AMR compression HO criterion is: C/I DL > HOTHAMRCDL and C/I UL > HOTHAMRCUL. Standard AMR decompression HO criteria are: C/I DL < HOTHAMRDDL or C/I UL < HOTHAMRDUL.
116
MN1789EU11MN_0001
2005 Siemens AG
Siemens
BTS
BSC
TRFCT
Check, whether or not traffic load > HRACTAMRT1 If TRUE, AMR compression HO is started in that cell: SET ATTRIBUTE: "AMR COMPRESSION HO ENABLED"
TRFCT
Check, whether or not traffic load > HRACTAMRT1 If TRUE, AMR compression HO is started in that cell:
...
Fig. 33 AMR traffic control
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
MN1789EU11MN_0001
2005 Siemens AG
117
Siemens
4.5.2.2
Advanced AMR compression/decompression HO (EADVCMPDCMHO=TRUE) algorithm additionally considers current level and PWRC situation when deciding on whether to compress or decompress the call. In this context the new parameters HOTHCMPLVDL, HOTHCMPLVUL, HOTHDCMLVDL and HOTHDCMLVUL are introduced and the new decision criteria defined. An advanced AMR compression HO from AMR FR to AMR HR is triggered if for a particular AMR FR call the following conditions are fulfilled: RXLEVUL>HOTHCMPLVUL and C/I UL>=C/Imax or C/I UL + MS_PWRRED>HOTHAMRCUL and RXLEVDL>HOTHCMPLVDL and C/I DL>=C/Imax or C/I DL + BS_PWRRED>HOTHAMRCDL. An advanced AMR decompression HO from AMR HR to AMR FR is triggered if for a particular AMR HRcall the following conditions are fulfilled: RXLEVUL<HOTHCMPLVUL or C/I UL<C/Imax and C/I UL + MS_PWRRED<HOTHAMRDUL or RXLEVDL<HOTHDCMLVDL or C/I DL<C/Imax and C/I DL + BS_PWRRED<HOTHAMRDDL, where MS_PWRRED=MS power reduction due to power control (in dB) BS_PWRRED=BS power reduction due to power control (in dB) C/Imax=20dBm.
118
MN1789EU11MN_0001
2005 Siemens AG
Siemens
4.5.3
EHRACTAMR parameter enables the Cell Load Dependent Activation of Half Rate for AMR calls on BTS basis. It has the same functionality as the parameter EHRACT for ordinary speech calls( see chapter1, section 4.2). This feature controls the allocation of AMR HR TCHs in such a way that AMR half rate TCHs are only assigned if the percentage of busy radio TCHs in the BTS or/and the percentage of busy Abis TCHs in the BTSM Abis channel pool have exceeded a configurable threshold. This threshold is defined by the parameters Half Rate Activation AMR threshold, HRACTAMRT1 and HRACTAMRT2 The parameters are used for two different features related to AMR calls - Cell Load Dependent Activation of Half Rate for AMR Calls - AMR Compression Handover. In case of the Cell Load Dependent Activation of Half Rate for AMR calls thresholds are relevant only if the parameter EHRACTAMR is set to TRUE. HRACTAMRT1 is the equivalent to the parameter HRACTT1 (introduced in BR6.0 for non-AMR as well as for AMR calls) for AMR and defines a traffic load threshold which is evaluated for the forced speech version selection for incoming AMR TCH seizures. If the cell traffic load exceeds the percentage defined by HRACTAMRT1 (or HRACTAMRT2), all incoming AMR calls or incoming AMR handovers, for which AMR HR is indicated as supported speech version, are forced to an AMR HR TCH. If the cell traffic load is below the percentage defined by HRACTAMRT1, all incoming calls are forced to AMR FR.
MN1789EU11MN_0001
2005 Siemens AG
119
Siemens
Database Parameters for intracell AMR handover Parameter EHRACTAMR Object BTS Range TRUE/FALSE (FALSE) EADVCMPDCMHO BTS TRUE/FALSE (FALSE) HRACTAMRT1 BTS 0..10000 Unit=0.01% (6000) Description Parameter to enable/disable Call Load Dependent Activation of HR for AMR calls Parameter to enable/disable AMR Advanced compression/decompression HO This parameter is the threshold that indicates the percentage of busy TCHs in case of standard cell or complete area of a concentric cell or far area of an extended cell. If the traffic load in the cell exceeds the threshold HRACTAMRT1, the BSC enables the AMR compression handover. This parameter is the threshold that indicates the percentage of busy TCHs in case of inner area of a concentric cell or near area of an extended cell. If the traffic load in the cell exceeds the threshold HRACTT2, the BSC enables the AMR compression handover.
HRACTAMRT2
BTS
120
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Object HAND
Description hoThresAMRComprDL hoThresAMRComprUL Handover FR HR is triggered only if both thresholds HOTHAMRCDL and HOTHAMRCUL are exceeded. hoThresAMRDecomprDL hoThresAMRDecomprUL Handover HR FR is triggered whenever any of the thresholds HOTHAMRDDL or HOTHAMRDUL is exceeded.
HOTHAMRDDL HOTHAMRDUL
HAND
HOTHCMPLVDL HOTHCMPLVUL
HAND
Handover threshold for compression Downlink and Unit=1 dB, Uplink if Advanced (NULL) compression/decompression initial value 40 (-70dBm) HO is selected. Handover threshold for decompression Downlink and Unit=1 dB, Uplink if Advanced (NULL) compression/decompression initial value 24 (-84dBm) HO is selected. 0 ... 63, NULL
HOTHDCMLVDL HOTHDCMLVUL
HAND
MN1789EU11MN_0001
2005 Siemens AG
121
Siemens
122
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Exercises
MN1789EU11MN_0001
2005 Siemens AG
123
Siemens
124
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Exercise 1
Title:
Cell Reselection
Task
Consider a static (not moving) MS GSM phase 1 of power class 3 camping on cell 1 in idle mode. The MS monitors the BCCH of cell 1 and cell 2 and measures the following levels: AV_RXLEV = 26 in cell 1 AV_RXLEV = 20 in cell 2 The following parameters are set: Cell 1: MS_TXPWR_MAX_CCH = 39 dBm RXLEV_ACCESS_MIN = 20 CELL_RESELECT_HYSTERESIS = 4dB MS_TXPWR_MAX_CCH = 33 dBm RXLEV_ACCESS_MIN = 14
Cell 2:
Does the MS perform a cell reselection 1. if cell 1 and cell 2 belong to one location area 2. if cell 1 and cell 2 belong to different location areas
MN1789EU11MN_0001
2005 Siemens AG
125
Siemens
126
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Exercise 2
Title:
Cell Reselection
Task
Calculate the time in which mobile station will perform cell reselection due to Downlink Signaling Failure. The Number of Multiframes between Paging blocks is set to value NFRAMEPG=4.
MN1789EU11MN_0001
2005 Siemens AG
127
Siemens
128
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Exercise 3
Title:
Handover Decision
Task
Consider of output power P = 39 dBm in connected mode served by cell 1. In cell 1 the following handover parameter are valid (consider only the downlink in the following): A_QUAL_HO A_LEV_HO A_PBGT_HO W_QUAL_HO W_LEV_HO =7 =7 =8 =3 =3 MS_TXPWR_MAX = 39 L_RXQUAL_DL_H L_RXLEV_DL_H L_RXLEV_DL_IH =4 = 12 = 25
Furthermore, cell 1 has the following adjacent cells: Parameters for Adjacent Cells. adjacent cell parameter ARFCN_NCELL BSIC MS_TXPWR_MAX RXLEV_MIN HO_MARGIN cell 2 35 00 37 16 6 dB cell 3 13 00 39 16 ?
The measurement reports for the last 8 SACCH frames have contained the following values:
MN1789EU11MN_0001
2005 Siemens AG
129
Siemens
Measurement Values: F: FULL, S: SUB. SACCH frame RXQUAL_SERV RXLEV_SERV BCCH_FREQ_NC ELL/ BSIC RXLEV_NCELL BCCH_FREQ_NC ELL/ BSIC RXLEV_NCELL 1 3S 25S 0/ 00 14 1/ 00 15 2 3S 16 S 0/ 00 15 1/ 00 16 3 4F 13 F 0/ 00 16 1/ 00 17 4 4F 15 F 0/ 00 17 1/ 00 18 5 6F 12 F 0/ 00 17 1/ 00 18 6 4S 16 S 0/ 00 18 1/ 00 19 7 5S 13 S 0/ 00 19 1/ 00 20 8 7F 10 F 0/ 00 20 1/ 00 21
Due to DL power control the BTS transmit power level is reduced by the following values: PWR_C_D 8 8 8 6 6 6 4 2
1. Which cell corresponds to BCCH_FREQ_NCELL = 0? 2. What are average values for RXLEV_DL RXQUAL_DL PBGT ( cell 2), PBGT ( cell 3)? 3. Is cell 2 included within the target cell list for a handover? 4. Which value for HO_MARGIN (cell 1 cell 3) is required to allow a better cell handover to cell 3? 5. Assume that a better cell handover to cell 3 occurs. Some seconds after the handover the received level form cell1 has increased by 6 dB, while the received level from the new serving cell 3 remains constant. To which HO_MARGIN (cell 3 cell 1) has to be set to prevent a back-handover to cell?
130
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Solutions
MN1789EU11MN_0001
2005 Siemens AG
131
Siemens
132
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Solution 1
Title:
Cell Reselection
Task
For a phase 1 MS the following conditions for cell reselection have to be fulfilled: for 1. own location area C1 (cell 2) > C1 (cell 1), for 2. different location areas C1 (cell 2) > C1 (cell 1) + CELL_RESELECT_HYSTERESIS. The C1 value is given by C1 = AV_RXLEV - ACCESS_MIN - Max (0, MS_TXPWR_MAX_CCH - P) i.e. for this scenario one has (power class 3 = 37 dBm): C1 (cell 1) = 26 - 20 - Max (0, 39-37) = 4 C1 (cell 2) = 20 - 14 - Max (0, 33-37) = 6 If cell 1 and cell 2 belong to the same location area, cell reselection takes place. If they belong to different location areas and if CELL_RESELECT_HYSTERESIS > 2 dB, no cell reselection takes place.
MN1789EU11MN_0001
2005 Siemens AG
133
Siemens
134
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Solution 2
Title:
Cell Reselection
Task
MS sets its Downlink Signaling Counter initial value according to the value of the NFRAMEPG broadcasted in the BCCH signal: DSC0 = round (90/NFRAMEPG) =round 90/4=22 Thus the initial DSC counter value will be set to 22. In each BS_PA_MFRMS time period MS tries to decode paging message and if the decoding is unsuccessful the counter value is decremented by 4, i.e. DSCt+1 = DSCt 4. After the expiry of the first BS_PA_MFRMS time period (4x235ms= 0,94s) as MS can not decode paging message the counter value is decremented DSC1 = DSC0 4 = 18; after the second BS_PA_MFRMS time period (2x4x235ms 1,9s) counter value becomes DSC2 = DSC1 4 = 14; . After expiry of the sixth BS_PA_MFRMS period counter value becomes DSC6 = DSC5 4 = 2-4=-2<0 and the condition for cell reselection due to Downlink Signaling Failure is fulfilled. Needed time for cell reselection is 6xBS_PA_MFRMS=6x0,94s5,6s.
MN1789EU11MN_0001
2005 Siemens AG
135
Siemens
136
MN1789EU11MN_0001
2005 Siemens AG
Siemens
Solution 3
Title:
Handover Decision
Task
1. The cell with BCCH_FREQ_NCELL = 0 is the lowest ARFCN of the BCCH frequencies (among the neighbor cells of cell 1), i.e. cell 3. 2. The averaging windows for RXLEV and RXQUAL of the serving cell contain 7 values. Since the weight for full values is three, the FULL values of SACCH frames 28 are taken with multiplicity 3; while SUB values are taken with multiplicity 1, sum up and the sum is divided with the sum of their weighting factors according to the new measurement preprocessing algorithm. Therefore one has: AV_RXQUAL = (3*7+1*5+1*4+3*6+3*4+3*4+1*3) / (3+1+1+3+3+3+1) = 5 AV_RXLEV = (1*16+3*13+3*15+3*12+1*16+1*13+3*10) / (3+1+1+3+3+3+1) = 13 For calculation of the power budget the values of SACCH frame 1...8 are averaged without taking into account multiplicities. The power budget is given by the following formula: PBGT(n) = RXLEV_NCELL(n) - (RXLEV_DL + PWR_C_D) + Min(MS_TXPWR_MAX, P) - Min(MS_TXPWR_MAX(n), P) For the average values one has: Min (MS_TXPWR_MAX, P) - Min (MS_TXPWR_MAX (cell 2), P) = 2 Min (MS_TXPWR_MAX, P) - Min (MS_TXPWR_MAX (cell 3), P) = 0 RXLEV_DL + PWR_C_D = 15 + 6 = 21 RXLEV_NCELL (cell 2) = 18 RXLEV_NCELL (cell 3) = 17 => PBGT (cell 2) = 18 - 21 + 2 = - 1 PBGT (cell 3) = 17 - 21 + 0 = - 4 3. Although AV_RXQUAL > L_RXQUAL_DL_H no quality handover is initiated: no intracell quality handover since AV_RXLEV < L_RXLEV_DL_IH no intercell quality handover since the BTS transmit power is not at its maximum according to given values for the power. Furthermore, no level handover is initiated. Since for a power budget handover the target cell list only contains cells with PBGT (n) > HO_MARGIN(n) - which is not fulfilled by cell 2 - cell 2 is not included in the target cell list.
MN1789EU11MN_0001
2005 Siemens AG
137
Siemens
4. To allow a better cell handover to cell 3, the HO_MARGIN (cell1 cell 3) has to be set to 5dB or a lower value. 5. PBGT (cell 3 cell 1) = - PBGT (cell 1 cell 3) + 6 dB improvement of cell1 = 10 dB hence to prevent a power budget handover from cell 3 to cell1, HO_MARGIN (cell 1 cell 3) has to be set to 10 dB or higher.