fluid sensors and diagnostic systems position sensors and object recognition

bus, identification and control systems

ifm efector close to you!

ifm efector close to you! visit our website: www.ifmefector.com.au

Over 70 locations worldwide at a glance at www.ifm.com


Australia ifm efector pty ltd. P.O. Box 4084 Suite 3, 745 Springvale Road Mulgrave VIC 3170 Tel. 1300 365 088 Fax 1300 365 070 sales.au@ifm.com New Zealand ifm efector pty ltd. Unit B, 20 Cain Road Penrose, Auckland Tel. +64 / 95 79 69 91 Fax +64 / 95 79 92 82 sales.nz@ifm.com www.ifm.com/nz

We reserve the right to make technical alterations without prior notice. 04/10

ifm the company General information List of articles / approvals Inductive sensors Capacitive sensors Cylinder sensors Safety technology Valve sensors Photoelectric sensors infrared / redlight Photoelectric sensors laser Photoelectric sensors fibre optics Photoelectric sensors specific systems Object recognition Encoders Evaluation systems Level sensors Flow sensors Pressure sensors Temperature sensors Diagnostic systems Bus system AS-interface Multicode reading systems RF-identification systems Power supplies Connection technology ifm worldwide addresses

6810 17 39 49 59 65 69 87 93 -

7 9 15 37 47 56 62 67 84 91 98

101 - 106 109 - 112 115 - 119 121 - 125 127 - 135 137 - 150 153 - 164 167 - 180 183 - 188 191 - 206 209 - 211 213 - 216 219 - 222 225 - 234 236 - 237

ifm the company

The company in your vicinity.

State-of-the-art communication. With the right address www.ifm.com only a mouse click separates you from the world of automation technology. See the power of our products in interactive representations. Gain an impression with 3-dimension-al views of our units. Download CAD drawings for direct integration in your applications. And one more innovation on the internet: The e-shop already available in many countries. Order online now even faster, more convenient and reliable. We are there for you. Close contact with our customers is part of our success. Therefore we have consistently developed our sales network right from the start. Today ifm electronic is represented in more than 70 countries close to you! With application advice and service at the heart of our operation. For the introduction of new products and technologies we support you with workshops and seminars in our training centres or in your plant.

Security by success. Since its foundation in 1969 ifm electronic has constantly grown, now having more than 3300 employees worldwide, and achieved a turnover of EUR 340 million in 2009. This success gives you the security of having a reliable partner for the implementation of your automation projects. Comprehensive service and a warranty of up to 5 years on standard units are just two examples of this reliability.
500 sales development in million EUR 400 300 200 100 0 1970

1980

1990

2000

Turnover development since 1970.

www.ifm.com

ifm the company

A sign of innovation.

Not only components. ifm stands for a large range of different sensors and systems for automation. Our range of more than 8000 articles guarantees flexibility and compatibility. So there is always a reliable solution for your automation projects from the individual sensor with practical accessories to the complete system. Availability guaranteed. Your deadlines matter to us. That is why we are constantly optimising our production processes in order to be able to quickly and flexibly produce large quantities at a constantly high quality and to continue to shorten delivery times. Your order is dispatched via our centralised logistics centre reliably and on time. Quality as part of our philosophy. The quality standard of our products is an integral part of our company philosophy. And we guarantee it! So we provide you, the users, with a maximum degree of security: By means of our own production technology, ifm film technology, as well as by means of extensive quality assurance measures such as 100 % final testing. By quality we understand, for example, ecologically conscious production Made in Germany!

The development of innovative products is one of our core competences. Under the name of i-step we have come up with a new product generation which implements sophisticated technologies in industrially compatible and easy to handle products. From high-quality standard solutions to products specially tailored to the requirements of the individual industries from mobile machines to the food industry.

www.ifm.com

General information

www.ifm.com Information around the clock and around the globe in 22 languages on the internet.

Information - product innovations - company news - exhibition info - locations - jobs Documentation - data sheets - operating instructions - manuals - approvals - CAD data Communication* - request for documents - recall service - live advice - newsletter

Selection - interactive product selection aids - configuration tools - data sheet direct Animation - virtual product animations - flash movies (video sequences) Application - applications - product recommendations - calculation aids Transaction* - e-shop processing - e-procurement catalogues - B2B services

*Some offered information is available country-specific

www.ifm.com

General information

Convenient order processing via the e-shop** on the internet.

Secured authentication Customer-related price indication Real time availability check Personal product favourites Online parcel tracking

Individual order history Convenient quick input form Simple order processing Management of shipping addresses Confirmations by e-mail

** Already available in many countries.

www.ifm.com

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

AC002S AC004S AC005S AC007S AC009S AC010S AC012S AC015S AC030S AC031S AC032S AC1144 AC1146 AC1147 AC1212 AC1218 AC1220 AC1221 AC1236 AC1244 AC1326 AC1327 AC1337 AC1354 AC1375 AC1376 AC2086 AC2216 AC2225 AC2251 AC2252 AC2254 AC2257 AC2264 AC2411 AC2412 AC2417 AC2451 AC2452 AC2457 AC2729 AC2730 AC2900 AC2904 AC2910 AC2916 AC3000 AC4000 AC4002 AC4007

CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS CE, CSA, UL CE CE, CRUUS CE, CUL CE CE CE CE CE CE, CUL CE, CRUUS CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE CE CE CE CE CE, CUL CE, CRUUS

197 197 197 197 197 198 198 198 197 197 197 199 193 193 194 194 194 194 194 194 193 193 193 193 193 193 195 194 193 194 194 194 194 194 195 196 195 195 196 195 194 195

AC4008 AC5000 AC5003 AC5014 AC5015 AC5031 AC5204 AC5208 AC5214 AC5215 AC5222 AC5228 AC5235 AC5246 DD2003 DI0001 DI5001 DI5009 DI6001 DN1030 DN1031 DN2013 DN2014 DN2032 DN2033 DN2035 DN2036 DN3011 DN3012 DTA100 DTA300 DX2003 E10017 E10191 E10200 E10734 E10735 E10736 E10737 E11030 E11031 E11032 E11033 E11034 E11036 E11047 E11048 E11078 E11220 E11221 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE, CUL CE CE CE CE, CUL CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS, CUL CE, CRUUS, CUL CE, CUL CE, CUL CE CUL CUL

200 196 196 196 196 197, 199 195 195 195 195 195 197 195 197 123 123 123 123 123 221 221 221 221 221 221 221 221 221 221 198, 215 198, 215 123 159, 173, 29 228 228 28 28, 43 124, 28, 44 124, 28, 44 44 44 44 44 44 44 29 29 44 230 230

E11223 E11224 E11232 E11248 E11249 E11495 E11496 E11498 E11499 E11504 E11505 E11508 E11509 E11521 E11530 E11531 E11533 E11534 E11572 E11664 E11697 E11796 E11797 E11798 E11799 E11801 E11816 E11817 E11818 E11819 E11820 E11821 E11822 E11823 E11877 E11914 E11928 E11929 E11958 E11959 E11960 E11961 E12004 E12153 E12208 E12209 E19503 E20004 E20005 E20600 CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS

230 230 111, 228 228 228 230 230 230 230 228 228 227 227 28 29 29 29 29 185 185 228 54 54 54 54 54 53 53 53 53 53 53 53 53 53 54 54 61 54 54 54 54 54 45 67 67 29 77 77 96

CE, CUL CE, CUL CE, CUL CE, CUL

196 196 196 196 200

CE CE

200 200 200

www.ifm.com

10

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

E20615 E20639 E20718 E20722 E20738 E20765 E20767 E20768 E20773 E20774 E20860 E20861 E20870 E20873 E20874 E20903 E20907 E20911 E20915 E20939 E20941 E20952 E20953 E20954 E20956 E20965 E20969 E20974 E20984 E20993 E20994 E21015 E21084 E21087 E21088 E21117 E21120 E21125 E21126 E21166 E21200 E21237 E2D101 E2D110 E2D200 E2I200 E30006 E30007 E30016 E30017 CE

95 95 29, 44 104, 90 228 96 96 96 96 96 29 29 29, 44 29, 44 29, 44 78 78 78 78 111, 112 111, 211 111 77 77 77 78 78 78, 90 78 89 89 78 79 104, 79 215, 79 79 79 78 78 111, 211 78 78 104, 90 111, 211 111 211 132, 159 132, 160 174 174

E30018 E30047 E30052 E30055 E30056 E30064 E30089 E30090 E30094 E30098 E30104 E30112 E30115 E30116 E30122 E30128 E30393 E30396 E30399 E30400 E30401 E30402 E30403 E33001 E33002 E33201 E33202 E33222 E33401 E33402 E33701 E33702 E33721 E33722 E34410 E35010 E37010 E3D103 E3D200 E40057 E40096 E40099 E40101 E40107 E40114 E40115 E40124 E40128 E40129 E40138 EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG EHEDG EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG, FDA EHEDG EHEDG CE EHEDG FDA EHEDG EHEDG

174 174 132, 161 174 174 161 174 174 159, 175 185 132, 159 111, 186 187 160 132, 145 161 175 159, 173 132, 159 132, 160 132, 160 132, 160 175 132, 161 161 132, 144 144, 160 144, 160 175 175 132, 144 144, 160 144, 160 145, 160 174 175 175 112 112 144 144, 175 144, 175 144, 174 175 143, 174 143 144, 174 143, 174 144 144

E40189 E40196 E40199 E43201 E43202 E43203 E43204 E43205 E43207 E43208 E43209 E43901 E43903 E43910 E60028 E60033 E60034 E60063 E60064 E7001S E7005S E70062 E70096 E70213 E70230 E70231 E70297 E70320 E70354 E70413 E70454 E73004 E75232 E80302 E80317 E80320 E89005 E89150 EBC027 EBC031 EBC035 ENC02A ENC05A ENC11A EVC002 EVC003 EVC005 EVC006 EVC094 EVC142 CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CE CE CUL CUL CRUUS

145 145 145 131 131 131 131 131 131 131 131 44 45 131 118 118 118 118 118 199 199 200 199 199 198 198 199 199 196, 199 200 196, 199 199 200 200, 215 200, 215 200, 215 123 124 229 229 229 231 231 231 227, 229 227, 229 227, 229 227, 229 228 227

www.ifm.com

11

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

EVC143 EVC145 EVC146 EVC148 EVC149 EVC151 EVC152 EVC154 EVC155 EVT001 EVT002 EVT004 EVT005 EVT007 EVT008 EVT010 EVT013 EVT040 EVT041 EVT042 EVT043 EVT044 EVT058 EVT060 EVT061 EVT062 EVW002 EVW003 EVW005 EVW006 EVW008 EVW009 G1501S G1502S G1503S G2001S GF711S GG711S GI711S ID0013 ID5046 ID5058 ID5059 IE5338 IE5340 IE5343 IE5345 IER200 IF0005 IF0007

CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CRUUS CE, CUL CE CE, CUL CE CE, CUL CE, CUL CCC, CE CCC, CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE CCC, CE

227 227 227 227 227 227 227 227 227 230 230 230 230 230 230 231 230 230 230 230 230 230 231 231 231 231 229 229 229 229 229 229 61 61 61 104 61 61 61 21 22 22 25 19 19 19 19 24 20 20

IF502A IFC204 IFC205 IFC206 IFM205 IFM206 IFR200 IFS204 IFS205 IFS208 IFS209 IFT200 IFT202 IFT203 IFT205 IFT206 IFT208 IFT240 IG0011 IG0012 IG509A IGC204 IGC205 IGC206 IGM204 IGM205 IGR200 IGS204 IGS205 IGS208 IGS209 IGT200 IGT202 IGT203 IGT205 IGT206 IGT208 IGT247 II0011 II0012 II501A IIC200 IIC201 IIM208 IIM209 IIR200 IIS204 IIS205 IIS206 IIS207

CE CE, CUL CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE, CUL CCC, CE CE CE, CUL CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, CCC CE, CUL, CCC CE CE, CUL CE, CUL CCC, CE, CUL, E1 CCC, CE, CUL, E1 CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL

28 23 23 23 24 24 24 21 21 21 21 25 26 25 26 26 26 25 20 20 28 23 23 23 24 24 24 21 21 21 22 26 26 26 26 26 26 25 20 20 28 23 23 24 24 24 22 22 22 22

IIT002 IIT200 IIT202 IIT204 IIT205 IIT207 IIT209 IIT228 IL5020 IM0010 IM0011 IM0049 IM0054 IM5020 IM5037 IM5038 IM503A IM5046 IM504A IM5115 IM5116 IM5117 IM5123 IM5124 IM5126 IM5127 IM5136 IN5121 IN5129 IN5409 IS5026 IS5070 IT5042 IT5043 IV5003 IV5004 IV5025 IY5051 IZ5047 IZ5048 IZ5051 JAT201 KD0009 KD5018 KG0009 KG0010 KG5065 KI0016 KI0020 KI0054

CCC, CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE, CUL CCC, CE, CUL CCC, CE CCC, CE CE, CUL CCC, CE CCC, CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE CE CE CE, CUL CE CE, CUL CE, CUL CE CE CE CE CE, CUL CE, CUL CE CE CCC, CE CE CCC, CE CCC, CE CE, CUL CCC, CE, CUL CCC, CE, CUL CE

27 26 27 26 26 27 27 25 19 20 20 21 21 20 20 20 28 20 28 22 22 22 22 22, 25 22, 25 23 22 19 19 67 19 19 19 19 20 20 25 19 19 19 19 23 42 41 41 41 42 41 42 43

www.ifm.com

12

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

KI5001 KI5002 KI5030 KI5082 KI5084 KI5085 KI5087 KQ6001 KQ6003 KQ6005 KX5001 LI5141 LI5142 LI5143 LI5144 LK1022 LK1023 LK1024 LK3122 LK3123 LK3124 LK8122 LK8123 LK8124 LR3000 LR7000 LR8000 MK5100 MK5101 MK5102 MK5103 MK5104 MK5106 MK5107 MK5108 MK5110 MK5111 MK5138 MK5139 MK5140 MK5157 MK5300 MK5301 MK5302 MK5306 MK5307 MR0100 MR0107 N0531A N0532A

CE, CUL CE, CUL CCSAUS, CE, FM, IEC CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCSAUS, CE, FM CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE, CSA, FM, IEC CE, CSA, FM, IEC

41 41 43 42 41 41 41 42 42 42 43 131 131 131 131 129 129 129 129 129 129 129 129 129 129 129 129 51 51 51 51 51 51 51 51 52 52 52 52 52 52 52 53 53 52 53 51 51 28, 43 28, 43

N0534A NF500A NF501A NG500A NG501A NI500A NI501A O1D100 O1D101 O1D103 O1D105 O1D106 O1D155 O1D300 O2D220 O2I100 O3D200 O4E500 O4H500 O4P200 O4P500 O4S500 O5C500 O5E200 O5G500 O5H200 O5H500 O5P200 O5S200 O7E200 O7H200 O7H202 O7H204 O7P200 O7S200 OBF500 OD5005 OD5007 OD5009 OD5011 OD5013 OG0030 OG0033 OG0035 OG0039 OG5123 OG5124 OG5125 OG5126 OG5127

CE, CSA, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CCSAUS, CE, FM, IEC CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE CE, CUL CE CE CE CE CE CCC, CE, CUL CCC, CE CCC, CE CCC, CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL

28, 43 27 27 27 27 27 27 103 89 103 103 103 103 103 111 211 111 77 77 77 77 77 103 76 103 76 76 76 76 76 76 76 76 76 75 95 103 103 104 104 104 73 73 73 73 72 72 72 72 72

OG5128 OG5129 OGE100 OGE200 OGE280 OGE281 OGE500 OGE700 OGH200 OGH280 OGH300 OGH500 OGH580 OGH581 OGH700 OGP100 OGP200 OGP201 OGP280 OGP281 OGP282 OGP300 OGP500 OGP700 OGS100 OGS200 OGS280 OGS500 OGS700 OGT100 OH5003 OH5005 OH5007 OH5011 OH5012 OJ5023 OJ5027 OJ5032 OJ5071 OJ5122 OJ5126 OJ5130 OJ5131 OJ5148 OJ5154 OJ5158 OJ5186 OL0004 OL0005 OL0006

CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CCC, CE CCC, CE CE

72 72 71 71 73 73 71 89 71 73 72 72 73 73 89 71 71 71 73 73 73 72 72 89 71 71 73 71 89 71 74 74 74 74 74 74 74 74 74 75 75 74 74 75 89 89 103 75 75 75

www.ifm.com

13

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

OL0007 OO5000 OO5001 OO5002 OO5003 OY120S OY121S OY122S PA3020 PA3021 PA3022 PA3023 PA3024 PA3026 PA3027 PA3028 PA3029 PA3060 PF2652 PF2653 PF2654 PF2656 PF2657 PF2658 PG2451 PG2452 PG2453 PG2454 PG2456 PG2457 PG2458 PG2489 PG2789 PG2793 PG2794 PG2795 PG2796 PG2797 PG2798 PG2799 PI1093 PI1094 PI1095 PI1096 PI1097 PI1099 PI1693 PI1694 PI1695 PI1696

CCC, CE CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE CE CE CE CE CE CE CE CE, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA

75 95 95 95 95 104 104 104 156 156 156 156 156 156 156 130, 156 156 156 158 158 158 158 158 158 158 158 158 158 158 158 158 158 130, 158 158 158 158 130, 158 130, 158 130, 158 130, 158 157 157 157 157 130, 157 130, 157 157 157 157 157

PI1697 PI1698 PI1699 PI2093 PI2094 PI2095 PI2096 PI2097 PI2098 PI2099 PI2789 PI2793 PI2794 PI2795 PI2796 PI2797 PI2798 PI2799 PIM693 PIM694 PK6520 PK6521 PK6522 PK6523 PK6524 PM2053 PM2054 PM2057 PM2058 PMP094 PMP095 PMP096 PMP097 PN2009 PN2020 PN2021 PN2022 PN2023 PN2024 PN2026 PN2027 PN2028 PN2069 PP2001 PQ7809 PQ7834 PS3208 PS3407 PS3417 PT3550

CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE CE CE CE CE CE, CUL

157 157 157 157 157 157 157 130, 157 130, 157 130, 157 130, 157 157 157 157 130, 157 130, 157 130, 157 130, 157 158 158 155 155 155 155 155 159 159 159 159 159 159 159 159 155 155 155 155 155 155 155 155 155 129, 155 159 155 155 130, 156 130, 156 130, 156 156

PT3551 PT3552 PT3553 PT3554 PT9550 PT9551 PT9552 PT9553 PT9554 PY2068 RB1015 RB6009 RB6015 RB6029 RM3005 RM7003 RM7004 RN7003 RN7004 RO6344 RO6345 RU1016 RU1025 SD2000 SD5000 SD6000 SD6100 SD8000 SD9000 SF211A SF221A SF320A SF321A SF5200 SF5350 SF5700 SF5800 SF6200 SI5000 SI5004 SI5006 SI5007 SI5010 SI6600 SI6700 SI6800 SL0101 SL5101 SM6050 SM6100

CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CRUUS CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL TIIS

156 156 156 156 156 156 156 156 156 129, 155 117 117 117 117 117 118 118 117 117 117 117 117 117 142 142 142 143 142 142 141 141

IEC IEC CUL CUL CUL CUL CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE, CUL, EHEDG, FDA CE CE CE, CUL CE, CUL

141 141 140 140 140 140 140 139 139 139 140 139 140 140 140 142 142 139 139

www.ifm.com

14

List of articles / approvals

Order no.

Approvals

Catalogue page

Order no.

Approvals

Catalogue page

SM7100 SM8100 SN0150 SN2301 SN2302 SQ0500 SR0150 SR2301 SR5900 SR5906 SU7000 SU8000 SU9000 TA3130 TA3131 TA3231 TA3430 TA3431 TA3437 TAA131 TAA431 TAD181 TAD981 TAP18A TAP98A TK6130 TK6330 TK7130 TK7330 TK7480 TM0061 TM9550 TN2531 TN7531 TP3237 TR2432 TR7432 TR8430 TS2051 TS2056 TS2229 TS2251 TS2256 TS5051 TT0061 TT1050 TT1061 TT1250 TT2050 TT2081

CE, CUL CE, CUL CE, CUL CE, IEC CE, IEC CE, CUL CE, CUL CE, IEC CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL, EHEDG CE, CUL, EHEDG CE, EHEDG CE, CUL CE, CUL, EHEDG CE, CUL, EHEDG CE, CUL, EHEDG CE, EHEDG, FDA CE, EHEDG, FDA CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL CUL, EHEDG CUL CE, CUL CE, CUL CE CE, CUL CE, CUL CE, CUL CUL

139 139 141 142 142 143 141 142 141 141 143 143 143 171 171 172 172 172 172 172 173 173 173 173 173 169 169 169 169 169 170 170 169 169 170 170 170 169 171, 172 171, 172 171 171 171

TT3250 TT5050 VE1001 VE1101 VE113A VKV021 VKV022 VSA001 VSA002 VSA003 VSE002 VSE100

CUL CUL CE, CUL CE, CUL CE, IEC CE, CUL CE CE, CUL CE, CUL CE, CUL CE, CUL CE, CUL

170 170 185 185 185 185 185 186 186 187 186 186

CUL CUL CUL CUL CUL CUL CUL

171, 172 172 170 172 170 170 171

www.ifm.com

15

16

Inductive sensors

Selection chart
Sensors for industrial applications, DC Sensors for industrial applications, AC and AC/DC Sensors with increased sensing range for industrial automation Photoelectric sensors Sensors for oils and coolants Sensors for oils and coolants with ceramic sensing face Sensors for mobile applications Full-metal sensors with non-stick coating against weld spatter Electromagnetic field immune sensors with correction factor K = 1 Electromagnetic field immune sensors Full-metal sensors for hygienic and wet areas Sensors for hygienic and wet areas with increased sensing range Sensors with ATEX / IECex approval 1D / 1G / 2G Switching amplifiers with ATEX / IECex approval Sensors with ATEX approval 3D Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
19 20 21 20 21 22 23 23 23 24 24 25 25 25 25 27 27 28 28 28 29 30 31

www.ifm.com

17

Inductive sensors

Inductive proximity sensors for all industries. Wide choice of housing styles and operating voltages. High-quality housing materials. Cylindrical housings from 3 to 34 mm diameter, various rectangular housings. Large supporting range of mounting and wiring accessories.

Inductive sensors In all automated processes sensors are absolutely necessary to provide the PLC with information. They supply the necessary signals on positions, limits or serve as pulse pick-ups for counting tasks or for monitoring rotational speed. Inductive and capacitive sensors are nowadays indispensable for industrial usage. As compared to mechanical switches they offer ideal conditions: non-contact operation free from any wear and tear, high switching frequencies and accuracy. In addition, they are insensitive to vibration, dust and moisture. Inductive sensors detect all metals without contact, capacitive sensors almost all solid and liquid media such as metal, glass, wood, plastic, water, oil, etc. Operating principle of inductive sensors Inductive sensors take advantage of the physical effect of the change in the quality factor in a resonant circuit caused by eddy current losses in conductive materials. This is how it works: A LC tuned circuit generates a high frequency electromagnetic field. This field is radiated from the active face of the sensor. If a conductive material enters this field, eddy currents will be formed in accordance with the law of inductance which draw energy from the oscillator. This reduces the oscillation amplitude. The change is converted into a switching signal. The operating principle permits detection of all metals irrespective of whether they are moving or not. The distance to the active face at which an electrically conductive material causes a change of signal in the sensor is called sensing range. The sensing range of an inductive sensor is defined by means of a target of mild steel (Fe 360). If the switch is damped by other metals, e.g. aluminium or copper, this is reduced. Using correction factors the user can calculate the attainable sensing ranges. Application sensors Every application has its own requirements as regards the sensors to be used. Temperature shocks, mechanical influences or aggressive cleaning agents are just a few of the possible environmental influences to which sensors are subjected. ifm electronic therefore offers inductive sensors which have been developed for special applications. This includes for example the use of selected housing materials such as stainless steel, LCP, PEEK, PBT or Duroplast. An innovative, consistent sealing concept from the sensor to the connector ensures ideal protection against ingress of moisture and aggressive media.
Typical application: Positioning sensing in automation technology; proximity sensors operate reliably and without wear.

High frequency electromagnetic field: The inductive sensor detects all metals.

www.ifm.com

18

Inductive sensors

Sensors for industrial applications, DC


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

Cable 2 m Output function


4 / L = 23

DC PNP Wiring diagram no. 1


0.8 f stainless steel 10...30 IP65 2000 100 1 IZ5051

3 / L = 27 4 / L = 27

1 nf 1.5 nf

stainless steel stainless steel

10...30 10...30

IP67 IP67

5000 1800

100 100

2 3

IZ5048 IZ5047

M5 / L = 23

0.8 f

stainless steel

10...30

IP65

2000

100

IY5051

6.5 / L = 27

2f

high-grade st. steel

10...30

IP67

1500

100

IT5042

6.5 / L = 27

4 nf

high-grade st. steel

10...30

IP67

500

100

IT5043

Cable 2 m Output function


M8 / L = 37

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 12


3f brass 10...30 IP67 1000 100 7 IE5343

M8 / L = 37

5 nf

brass

10...30

IP67

700

100

IE5345

M8 connector Output function


M8 / L = 40 3f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


brass 10...30 IP67 1000 100 9 IE5338

M8 / L = 40

5 nf

high-grade st. steel

10...30

IP67

700

100

10

IE5340

Cable 2 m Output function


40 x 8 x 8

DC PNP Wiring diagram no. 1


2.5 f brass 10...36 IP65 2000 250 11 IL5020

28 x 10 x 16

4 nf

PBT

10...36

IP67

2000

250

12

IS5070

Cable 2 m Output function


28 x 10 x 16 2f

DC PNP/NPN Wiring diagram no. 14


PBT 5...36 IP67 2000 200 13 IS5026

Cable 2 m Output function


40 x 12 x 26 40 x 12 x 26

DC PNP Wiring diagram no. 1


2f 4 nf PBT PBT 10...36 10...36 IP67 IP67 1400 1300 250 250 14 14 IN5121 IN5129

www.ifm.com

19

Inductive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f [Hz]

Iload [mA]

Drawing no.

Order no.

Terminals Output function


40 x 40 x 120 15 f

DC PNP Wiring diagram no. 2


PPE 10...36 IP65 350 250 15 IM5020

40 x 40 x 120

30 nf

PPE

10...36

IP65

100

250

15

IM5046

Terminals Output function


40 x 40 x 120 40 x 40 x 120 15 f 20 nf

DC PNP/NPN Wiring diagram no. 15


PPE PPE 10...55 10...55 IP65 IP65 > 350 > 300 400 400 15 15 IM5037 IM5038

Terminals Output function


40 x 40 x 118 40 x 40 x 118 15 f 20 f

DC PNP Wiring diagram no. 3


PBT PBT 10...60 10...60 IP67 IP67 150 150 200 200 16 17 IV5003 IV5004

f = flush / nf = non flush Sensors for industrial applications, AC and AC/DC


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f AC / DC [Hz] Iload AC / DC [mA] Drawing no. Order no.

Cable 2 m Output function


M12 / L = 71

AC Wiring diagram no. 4


2f brass 20...250 IP67 25 250 18 IF0005*

M12 / L = 71

4 nf

brass

20...250

IP67

25

250

19

IF0007*

Cable 2 m Output function


M18 / L = 80

AC/DC Wiring diagram no. 5


5f brass 20...250 IP67 25 / 50 350 / 100 20 IG0011*

M18 / L = 80

8 nf

brass

20...250

IP67

25 / 50

350 / 100

21

IG0012*

M30 / L = 81

10 f

brass

20...250

IP67

25 / 50

350 / 100

22

II0011*

M30 / L = 81

15 nf

brass

20...250

IP67

25 / 50

350 / 100

23

II0012*

Terminals Output function


40 x 40 x 120 40 x 40 x 120 15 f 20 nf

AC/DC Wiring diagram no. 6


PPE PPE 20...250 20...250 IP65 IP65 20 / 55 20 / 55 350 / 100 350 / 100 15 15 IM0011* IM0010*

www.ifm.com

20

Inductive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f AC / DC [Hz]

Iload AC / DC [mA]

Drawing no.

Order no.

1/2 connector Output function


40 x 40 x 66 35 nf

AC/DC Wiring diagram no. 7


PPE 20...250 IP67 20 / 50 350 / 100 24 IM0049*

M12 connector Output function


40 x 40 x 66 20 f

AC/DC Wiring diagram no. 7


PPE 20...250 IP67 25 / 140 350 / 100 25 IM0054*

Terminals Output function


105 x 80 x 40 60 nf

AC/DC Wiring diagram no. 16


modified PPE 20...250 IP65 4 350 / 100 26 ID0013*

f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors with increased sensing range for industrial automation
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 45 4f

DC PNP Wiring diagram no. 8


brass 10...36 IP67 700 100 27 IFS204

M12 / L = 50

7 nf

brass

10...36

IP67

700

100

28

IFS205

M12 connector Output function


M12 / L = 70 4f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


brass 10...30 IP67 500 100 29 IFS208

M12 / L = 70

7 nf

brass

10...30

IP67

500

100

30

IFS209

M12 connector Output function


M18 / L = 46 8f

DC PNP Wiring diagram no. 8


brass 10...36 IP67 400 100 31 IGS204

M18 / L = 51

12 nf

brass

10...36

IP67

300

100

32

IGS205

M12 connector Output function


M18 / L = 70 8f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


brass 10...30 IP67 400 100 33 IGS208

www.ifm.com

21

Inductive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f [Hz]

Iload [mA]

Drawing no.

Order no.

M12 connector Output function


M18 / L = 70 12 nf

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


brass 10...30 IP67 300 100 34 IGS209

M12 connector Output function


M30 / L = 50 15 f

DC PNP Wiring diagram no. 8


brass 10...36 IP67 100 100 35 IIS204

M30 / L = 50

22 nf

brass

10...36

IP67

100

100

36

IIS205

M12 connector Output function


M30 / L = 70 15 f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


brass 10...30 IP67 100 100 37 IIS206

M30 / L = 70

22 nf

brass

10...30

IP67

100

100

38

IIS207

M12 connector Output function


40 x 40 x 54 40 x 40 x 54 40 x 40 x 54 20 f 35 nf 40 nf

DC PNP Wiring diagram no. 8


PA (polyamide) PA (polyamide) PA (polyamide) 10...36 10...36 10...36 IP67 IP67 IP67 100 80 60 200 200 200 39 39 39 IM5115 IM5116 IM5117

M12 connector Output function


40 x 40 x 54 20 f

DC PNP Wiring diagram no. 9


PA (polyamide) 10...36 IP67 100 200 39 IM5123

40 x 40 x 54

20 f

PA (polyamide)

10...36

IP67

200

200

40

IM5124

40 x 40 x 54

40 nf

PA (polyamide)

10...36

IP67

60

200

39

IM5136

40 x 40 x 54

40 nf

PA (polyamide)

10...36

IP67

200

200

40

IM5126

92 x 80 x 40

50 f

PPE

10...36

IP67

70

250

41

ID5058

M12 connector Output function normally open / closed programmable) DC PNP Wiring diagram no. 8
105 x 80 x 40 60 nf PPE 10...36 IP67 100 250 42 ID5046

f = flush / nf = non flush

www.ifm.com

22

Inductive sensors

Photoelectric sensors
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 63 50 f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...30 IP68 / IP69K 1600 100 43 JAT201

f = flush / nf = non flush Sensors for oils and coolants


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


40 x 40 x 54 15 f

DC PNP/NPN Wiring diagram no. 17


PA (polyamide) 10...36 IP67 200 100 44 IM5127

f = flush / nf = non flush Sensors for oils and coolants with ceramic sensing face
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 45 M12 / L = 45 4f 4f

DC PNP Wiring diagram no. 8


brass brass 10...36 10...36 IP68 IP68 700 700 100 100 27 27 IFC206 IFC204

M12 / L = 50

7 nf

brass

10...36

IP68

700

100

28

IFC205

M18 / L = 46 M18 / L = 46

8f 8f

brass brass

10...36 10...36

IP68 IP68

400 400

100 100

31 31

IGC206 IGC204

M18 / L = 51

12 nf

brass

10...36

IP68

300

100

32

IGC205

M30 / L = 50

15 f

brass

10...36

IP68

100

100

35

IIC200

M30 / L = 50

22 nf

brass

10...36

IP68

100

100

36

IIC201

f = flush / nf = non flush

www.ifm.com

23

Inductive sensors

Sensors for mobile applications


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 70 4f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...60 IP67 / IP69K 400 200 45 IFM205

M12 / L = 70

7 nf

stainless steel

10...60

IP67 / IP69K

300

200

46

IFM206

M18 / L = 70

8f

stainless steel

10...60

IP67 / IP69K

200

200

47

IGM204

M18 / L = 70

12 nf

stainless steel

10...60

IP67 / IP69K

200

200

48

IGM205

M30 / L = 70

12 f

stainless steel

10...60

IP67 / IP69K

100

200

37

IIM208

M30 / L = 70

22 nf

stainless steel

10...60

IP67 / IP69K

100

200

38

IIM209

f = flush / nf = non flush Full-metal sensors with non-stick coating against weld spatter
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M8 / L = 60 2f

DC PNP Wiring diagram no. 8


stainless steel 10...36 IP67 / IP68 100 100 49 IER200

M12 / L = 60

4f

high-grade st. steel

10...36

IP67

100

50

IFR200

M18 / L = 70

6f

high-grade st. steel

10...36

IP67

100

51

IGR200

M30 / L = 70

12 f

high-grade st. steel

10...36

IP67

100

52

IIR200

f = flush / nf = non flush

www.ifm.com

24

Inductive sensors

Electromagnetic field immune sensors with correction factor K = 1


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


40 x 40 x 54 40 x 40 x 54 20 f 40 nf

DC PNP Wiring diagram no. 9


PA (polyamide) PA (polyamide) 10...36 10...36 IP67 IP67 200 200 200 200 40 40 IM5124 IM5126

f = flush / nf = non flush Electromagnetic field immune sensors


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


40 x 40 x 118 15 f

DC PNP Wiring diagram no. 8


modified PPE 10...60 IP67 50 200 53 IV5025

M12 connector Output function


92 x 80 x 40 50 f

DC PNP Wiring diagram no. 9


PPE 10...36 IP67 70 250 41 ID5059

f = flush / nf = non flush Full-metal sensors for hygienic and wet areas
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 60 3f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...36 IP68 / IP69K 100 100 50 IFT240

M18 / L = 70

5f

high-grade st. steel

10...36

IP68 / IP69K

100

100

51

IGT247

M30 / L = 70

10 f

high-grade st. steel

10...36

IP68 / IP69K

50

100

52

IIT228

f = flush / nf = non flush Sensors for hygienic and wet areas with increased sensing range
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 45 4f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...36 IP68 / IP69K 800 100 27 IFT203

M12 / L = 50

7 nf

high-grade st. steel

10...36

IP68 / IP69K

800

100

54

IFT200

www.ifm.com

25

Inductive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f [Hz]

Iload [mA]

Drawing no.

Order no.

M12 connector Output function


M12 / L = 70 4f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


high-grade st. steel 10...36 IP68 / IP69K 500 100 29 IFT205

M12 / L = 70

7 nf

high-grade st. steel

10...30

IP68 / IP69K

700

100

46

IFT202

Cable 6 m Output function


M12 / L = 50

DC PNP Wiring diagram no. 1


4f high-grade st. steel 10...36 IP68 / IP69K 800 100 55 IFT206

M12 / L = 61

7 nf

high-grade st. steel

10...36

IP68 / IP69K

800

100

56

IFT208

M12 connector Output function


M18 / L = 46 8f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...36 IP68 / IP69K 600 100 31 IGT203

M18 / L = 51

12 nf

high-grade st. steel

10...36

IP68 / IP69K

300

100

57

IGT200

M12 connector Output function


M18 / L = 70 8f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


high-grade st. steel 10...30 IP68 / IP69K 400 100 47 IGT205

M18 / L = 70

12 nf

high-grade st. steel

10...30

IP68 / IP69K

300

100

58

IGT202

Cable 6 m Output function


M18 / L = 57

DC PNP Wiring diagram no. 1


8f high-grade st. steel 10...36 IP68 / IP69K 600 100 59 IGT206

M18 / L = 62

12 nf

high-grade st. steel

10...36

IP68 / IP69K

300

100

60

IGT208

M12 connector Output function


M30 / L = 50 14 f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...36 IP68 / IP69K 50 100 35 IIT205

M30 / L = 50

22 nf

high-grade st. steel

10...36

IP68 / IP69K

100

100

61

IIT200

M12 connector Output function


M30 / L = 70 14 f

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


high-grade st. steel 10...36 IP68 / IP69K 50 100 37 IIT204

www.ifm.com

26

Inductive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f [Hz]

Iload [mA]

Drawing no.

Order no.

M12 connector Output function


M30 / L = 70 22 nf

3-wire DC PNP; 2-wire DC PNP/NPN Wiring diagram no. 13


high-grade st. steel 10...36 IP68 / IP69K 100 100 38 IIT202

1/2 connector Output function


M30 / L = 70 22 nf

AC/DC Wiring diagram no. 10


high-grade st. steel 20...140 IP68 / IP69K 25 / 100 200 62 IIT002

Cable 6 m Output function


M30 / L = 59

DC PNP Wiring diagram no. 1


22 nf high-grade st. steel 10...36 IP68 / IP69K 100 100 63 IIT207

M30 / L = 59

14 f

high-grade st. steel

10...36

IP68 / IP69K

100

100

64

IIT209

f = flush / nf = non flush Sensors with ATEX / IECex approval 1D / 1G / 2G


Type Dimensions [mm] Sensing range [mm] Material Unom. at 1 K [V] Ub [V] Internal capacit. [nF] Internal inductance [H] f [Hz] Drawing no. Order no.

M12 connector Output function Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P = 120 mW Wiring diagram no. 11
M12 / L = 45 4f brass 8.2 DC 7.5...30 210 115 700 27 NF501A

M12 / L = 50

7 nf

brass

8.2 DC

7.5...30

210

145

700

28

NF500A

M18 / L = 46

8f

brass

8.2 DC

7.5...30

200

190

400

31

NG501A

M18 / L = 51

12 nf

brass

8.2 DC

7.5...30

200

85

300

32

NG500A

M30 / L = 50

15 f

brass

8.2 DC

7.5...30

230

210

100

35

NI501A

M30 / L = 50

22 nf

brass

8.2 DC

7.5...30

250

120

100

36

NI500A

f = flush / nf = non flush

www.ifm.com

27

Inductive sensors

Switching amplifiers with ATEX / IECex approval


Type Ub [V] 24 Power / current consumption [VA] / [mA] / < 50 f [Hz] 5000 Ta [C] -20...60 2 transistor outputs PNP (100 mA, shortcircuit protection) IP20 Output Protection Drawing no. 65 Order no.

N0531A

24 24

/ < 50 / < 50

5000 5000

-20...60 -20...60

2 outputs (optocoupler, bipolar, 100 mA, short-circuit protection) 2 transistor outputs PNP (100 mA, shortcircuit protection)

IP20 IP20

65 65

N0532A N0534A

Sensors with ATEX approval 3D


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M12 / L = 60 3f

DC PNP Wiring diagram no. 8


high-grade st. steel 10...36 IP67 100 100 50 IF502A

M18 / L = 70

5f

high-grade st. steel

10...36

IP67

100

100

51

IG509A

M30 / L = 70

10 f

high-grade st. steel

10...36

IP67

50

100

66

II501A

M12 connector Output function


40 x 40 x 54 40 x 40 x 54 40 nf 20 f

DC PNP Wiring diagram no. 9


PA (polyamide) PA (polyamide) 10...30 10...30 IP5x IP5x 100 100 200 200 39 39 IM503A IM504A

f = flush / nf = non flush Accessories


Type Description Order no.

Angle bracket for type M8 Housing materials: stainless steel

E10734

Angle bracket for type M12 Housing materials: stainless steel

E10735

Angle bracket for type M18 Housing materials: stainless steel

E10736

Angle bracket for type M30 Housing materials: stainless steel

E10737

Mounting clamp 8 mm with end stop for type M8 Housing materials: PC

E11521

www.ifm.com

28

Inductive sensors

Type

Description

Order no.

Mounting clamp 34 mm Housing materials: PBT

E10017

Mounting clip 12 mm for smooth body switches - 12 mm Form V Housing materials: V4A

E11530

Mounting clip 18 mm for smooth body switches - 18 mm Form V Housing materials: V4A

E11531

Mounting clip Form O for type M12 Housing materials: stainless steel

E11533

Mounting clip Form O for type M18 Housing materials: stainless steel

E11534

Mounting clamp 12 mm with end stop for type M12 Housing materials: PC

E11047

Mounting clamp 18 mm with end stop for type M18 Housing materials: PC

E11048

Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: clamp: diecast zinc / fixture: steel

E20718

Mounting set 12.2 mm Clamp mounting free-standing M8 for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc

E20860

Mounting set 12.2 mm Clamp mounting free-standing M8 for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20861

Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20870

Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc

E20873

Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20874

Plastic nut for flow plate M18 x 1 Housing materials: POM

E19503

www.ifm.com

29

Inductive sensors

Wiring diagrams
1 4 7 10

BN BK BU

L+

BN

L1

3 2

BU

L1 L+ N L

L1 L+

N L

2
1

5
/3 /4

11

L+

BN

L1 L+ N L

1 4 3

L+

L+ 1

BU

3
1 4 2 4: 2: 3 L L+

6
/3 /4

9
1
L+

1: connection to NAMURamplifier

L1 L+ N L

2
4

4: 2:

12

15

BN

L+

BN BK

L+

/3 /4

L+

/4

L+

BK

BU

/3

13

16
AC; DC NPN 1 2 3 4 L 5 1 2 L+ N L+ L1 L AC; DC NPN 1 2 3 4 5 1 2 3 L 4 5 L L+ L1 L N L+

L+

1 4

L+

DC PNP

DC PNP

14

3 4 5

WH

L+

BK

L+

BK

WH

17
L

L+

L+

www.ifm.com

30

Inductive sensors

Scale drawings - CAD download: www.ifm.com 1


23
4

9
40 32,5 28,5
M8x1 M8x1

16

LED

4 LED 4 x 90 13

2
27 3 17

10
40 32,5 23 8 M8x1 M8x1 4
LED 4 x 90

LED

3
27 4 15,4

13

11
LED

40 20 5

4
23 18 16 M5x0,5

LED

1 IL 5002 IL 5003 5 20 10

LED
8

2,7

M3

5
3,5 LED 27 6,5

1: sensing face 12
16 3,1 5,6 3,5

6
27 3,5 LED 8 6,5

27,8

8 10,4

7
2 35 M8x1

13
16 3,1 5,1 LED

LED

13 5,6 3,5

27

8 M8x1
2,75

4 LED 13

10,4

www.ifm.com

3,1

22,2

27 ,8

2,8

LED 10,2

3,1 LED 2,75

22,2

2,8

10,2

31

Inductive sensors

Scale drawings - CAD download: www.ifm.com 14


LED 26 LED 12 5 13

18
18 71 60 50

10

4 LED 17

40

3,2

32

18

16

19
18 71 60 46

15
LED LED 121 17

40

101

20
18 80 69 58

27

5,1

5,3

77 10,4

4 LED 24

32

30

21
18 80 69 50

61,5 LED

45,6

16
LED 118 40

4 LED 24

40

22
18 81 67 59

13

5,3

5,3

LED

LED

36

60

46

30

23
18 81 67 44 15

17
LED 118 40 40

29

LED

36

13

5,3

5,3

LED LED

58 7,3

60

46

www.ifm.com

32

30

M30 x1,5

M30 x1,5

58 7,3

M18 x1

M18 x1

M12 x1

1: threaded insert M3, depth 5.8 mm, max. tightening torque 1.2 Nm (screw fixing class 8.8) when brass insert in contact with counterpart.
9

M12 x1
4

3,2

Inductive sensors

Scale drawings - CAD download: www.ifm.com 24


66 40 1/2" 20UNF 2A LS100 40

28
50 39 32 M12 x1

5 M12 x1 4

34

17 5,4 10 LED 8,5

LED 4 x 90

17

29
70 59 50 M12 x1

30 20

5,4

6 46 61

33

4
LED 4 x 90

17

25
66 40 40

30
70 59 45 M12 x1

5 M12 x1 4

34 M12 x1

17

LED 4 x 90

17

5,4

LED
16

31
46 35 33 30 M12 x1 M18 x1 4 24 51 40 38 25 M12 x1 10 M18 x1 4
LED 4 x 90

30 20

5,4

10

6 46 61

33

26
105 9,3 5,5 40 40 12

LED 4 x 90

32

65 80

18 27

pot. LED

24

65

7,5

16

33 27
45 34 32 M12 x1 M12 x1
M12 x1
70 59 56,5 49

4
LED 4 x 90

17

4 LED 4 x 90 24

www.ifm.com

M18 x1

M12 x1

33

Inductive sensors

Scale drawings - CAD download: www.ifm.com 34


70 60 58 40

39
66 54 46 40

10

40
M18 x1

M12 x1

30 2 5,5

4 LED 4 x 90 24

29,5

35
50 39 37 33 M30 x1,5 M12 x1 30 M12 x1

46

1: LED yellow, 2: LED green


36

LED 4 x 90

40 36
50 39 37 15 19

5,5

40

66 54 46 40

M30 x1,5

M12 x1

30 2 5,5

LED 4 x 90

36

29,5

46 1

37
70 59 57 53 M30 x1,5 M12 x1

30 M12 x1 5,5

1: LED yellow, 2: LED green 41


112 92 9,3 40 5,5 40 20

LED 4 x 90

36

38
70 59 57 38 M12 x1

15 M30 x1,5 M12 x1

LED 4 x 90

36

5
65 7,5 1 17

65 80

LED

1: mounting on DIN rail

www.ifm.com

34

Inductive sensors

Scale drawings - CAD download: www.ifm.com 42


123 105 9,3 5,5 40 40 12

47
70 59 57 50 M12 x1 M18 x1 4 65 80
LED 4 x 90 pot. LED

M12 x1

18 27

24

48
65 7,5 16

43
63 52 43 M12 x1 M12 x1

70 59 57 40 M12 x1

10 M18 x1 4

LED 4 x 90

24

4 LED 4 x 90 17

49
60 49 33 66 54 46 40 M12 x1 M8x1 4 13

44

40

LED 4 x 90

30 2

29,5

50
60 49 40 M12 x1 M12 x1 4
LED 4 x 90

5,5

LED 46

30 M12 x1

17

5,5

51
70 59 57 50

45
70 59 50 M12 x1 M12 x1

M12 x1

LED 4 x 90

24

4 LED 17

52 46
70 59 45 M12 x1
70 58 57 50

M12 x1

M12 x1

4
LED

17

LED 4 x 90

36

www.ifm.com

M30 x1,5

M18 x1

35

Inductive sensors

Scale drawings - CAD download: www.ifm.com 53


LED 139 118

59
57 39,5 33 29 M18 x1 LED 4 x 90 4 24 62 44,5 38 24 10 M18 x1 LED 4 x 90 4 24 50 39 37 15 18 M30 x1,5 5 36 70 59 57 38 1/2"-20UNF-2A 15 M30 x1,5 36 5 M12 x1
50 37 29 M12 x1
LED 4 x 90

40

40
5

M12 x1

13

5,3

5,3

LED

58 7,3

60
30

60

46

54
50 39 32

61
M12 x1

M12 x1

4
LED 4 x 90

17

55

62

4 LED 17

56
61 44 28 5 5 M12 x1

LED 4 x 90

4 LED 4 x 90 17

63
59 42 35 16 15 M30 x1,5 LED 4 x 90 5 36 59 42 35 31 M30 x1,5 LED 4 x 90 5 36

57
51 40 38 25 M12 x1

10 M18 x1

4
LED 4 x 90

24

64

58
70 59 56 39 M12 x1

10 M18 x1

4
LED 4 x 90

24

www.ifm.com

36

Inductive sensors

Scale drawings - CAD download: www.ifm.com 65


20 112

66
70 58 57 50

35,5

LED

1: Combicon plug with screw terminals (optional)

www.ifm.com

120

LED 4 x 90

36

M30 x1,5

M12 x1

37

38

Capacitive sensors

Selection chart
Sensors for industrial applications, DC Sensors for industrial applications, AC and AC/DC Sensors for the detection of conductive media through a wall Sensors for the detection of granulates Sensors for the detection of granulates Sensors with ATEX approval Switching amplifiers with ATEX approval Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
41 41 42 42 42 43 43 43 43 45 45 46

www.ifm.com

39

Capacitive sensors

Capactive sensors for detection of non-metalic objects. Sensing range adjustable by means of a potentiometer. Plastic or metal housing for different applications. Housing styles from M12 cylindrical to 105 x 80 mm block. Assortment of tank and sight glass mounting acccessories.

Capacitive sensors Capacitive sensors are used for the non-contact detection of any objects. In contrast to inductive sensors, which only detect metallic objects, capacitive sensors can also detect non-metallic materials. Typical applications are in the wood, paper, glass, plastic, food and chemical industries. In a packaging system, capacitive sensors monitor that the contents of a cardboard box is complete, for example, or check the presence of non-metallic caps. Another application is to monitor the conveying of sheets of glass on a roller conveyor. Operating principle The capacitance between the active electrode of the sensor and the electrical earth potential is evaluated. An approaching object influences the electrical alternating field between these two capacitor plates and, consequently, the capacitance. This applies to metallic and non-metallic objects. By means of the potentiometer or the pushbutton the user can set the sensitivity. Increased noise immunity When detecting objects, very small changes in capacitance must be evaluated and converted into switching signals. This makes high requirements for the electronics. The sensors must be designed so that they are insensitive to fluctuations of the parasitic basic capacitances, as these can amount to a multiple of the change in capacitance to be measured. Moreover, the sensors must be insensitive to electromagnetic interference which typically occur in the application area. ifm electronic has developed future-oriented solutions to meet the high sensor requirements. A patented circuit concept efficiently prevents the mentioned problems and ensures reliable functioning for all relevant noise parameters.
Not only metal: Capacitive sensors detect almost all materials, here for example a log in a saw mill.

www.ifm.com

40

Capacitive sensors

Sensors for industrial applications, DC


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

Cable 2 m Output function


M30 / L = 81

DC PNP Wiring diagram no. 1


15 nf PBT 10...36 IP65 40 250 1 KI5002

Cable 2 m Output function


M30 / L = 81

DC PNP Wiring diagram no. 2


15 nf PBT 10...36 IP65 40 250 1 KI5001

M12 connector Output function


M30 / L = 90 8f

DC PNP Wiring diagram no. 3


high-grade st. steel 10...36 IP65 / IP67 10 100 2 KI5085

M30 / L = 90

15 nf

high-grade st. steel

10...36

IP65 / IP67

10

100

KI5087

M12 connector Output function


M30 / L = 90 8f

DC PNP/NPN Wiring diagram no. 9


high-grade st. steel 10...36 IP65 / IP67 10 100 2 KI5084

Terminals Output function


105 x 80 x 40 60 nf

DC PNP Wiring diagram no. 10


modified PPO 10...36 IP65 10 250 4 KD5018

f = flush / nf = non flush Sensors for industrial applications, AC and AC/DC


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f AC / DC [Hz] Iload AC / DC [mA] Drawing no. Order no.

Cable 2 m Output function


M18 / L = 84

AC/DC Wiring diagram no. 4


8 nf PBT 20...250 IP67 25 / 50 350 / 100 5 KG0009*

Cable 2 m Output function


M18 / L = 84

AC/DC Wiring diagram no. 5


8 nf PBT 20...250 IP67 25 / 50 350 / 100 5 KG0010*

Cable 2 m Output function


M30 / L = 81

AC/DC Wiring diagram no. 4


15 nf PBT 20...250 IP65 25 / 40 250 1 KI0016*

www.ifm.com

41

Capacitive sensors

Type

Dimensions [mm]

Sensing range [mm]

Material

Ub [V]

Protection

f AC / DC [Hz]

Iload AC / DC [mA]

Drawing no.

Order no.

Cable 2 m Output function


M30 / L = 81

AC/DC Wiring diagram no. 5


15 nf PBT 20...250 IP65 25 / 40 250 1 KI0020*

Terminals Output function


105 x 80 x 40 60 nf

AC/DC Wiring diagram no. 11


modified PPO 20...250 IP65 10 250 4 KD0009*

f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors for the detection of conductive media through a wall
Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

Cable 2 m Output function no. 12


20 x 14 x 48 12 nf

1x open collector with automatic load detection (DC PNP or DC NPN) Wiring diagram
PBT 10...36 IP65 / IP67 10 100 6 KQ6001

Cable with connector 0.04 m Output function Wiring diagram no. 9


20 x 14 x 48 12 nf PBT

1x open collector with automatic load detection (DC PNP or DC NPN)


10...36 IP65 / IP67 10 100 6 KQ6003

Cable with connector 0.1 m Output function


20 x 14 x 48 12 nf PBT

1x open collector DC PNP Wiring diagram no. 3


10...36 IP65 / IP67 10 100 6 KQ6005

f = flush / nf = non flush Sensors for the detection of granulates


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

M12 connector Output function


M18 / L = 87 12 nf

DC PNP/NPN Wiring diagram no. 9


PBT 10...36 IP65 / IP67 10 200 7 KG5065

M30 / L = 90

20 nf

PBT

10...36

IP65 / IP67

10

200

KI5082

f = flush / nf = non flush

www.ifm.com

42

Capacitive sensors

Sensors for the detection of granulates


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f [Hz] Iload [mA] Drawing no. Order no.

1/2 UNF-Connector Output function


M30 20 nf

AC/DC Wiring diagram no. 6


PBT 20...250 IP65 / IP67 10 150 9 KI0054*

f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Sensors with ATEX approval
Type Dimensions [mm] Sensing range [mm] Material Unom. at 1 K [V] Ub [V] Internal capacit. [nF] Internal inductance [H] f [Hz] Drawing no. Order no.

Cable 2 m Output function 120 mW Wiring diagram no. 7


M30 / L = 81

Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P =

15 nf

PBT

8.2 DC

7.5...15

375

40

KI5030

Cable 2 m Output function 120 mW Wiring diagram no. 8


M34 / L = 92

Connection to certified intrinsically safe circuits with the max. values U = 15 V / I = 50 mA / P =

15 nf

brass

8.2 DC

7.5...15

375

40

10

KX5001

f = flush / nf = non flush Switching amplifiers with ATEX approval


Type Ub [V] 24 Power / current consumption [VA] / [mA] / < 50 f [Hz] 5000 Ta [C] -20...60 2 transistor outputs PNP (100 mA, shortcircuit protection) IP20 Output Protection Drawing no. 11 Order no.

N0531A

24 24

/ < 50 / < 50

5000 5000

-20...60 -20...60

2 outputs (optocoupler, bipolar, 100 mA, short-circuit protection) 2 transistor outputs PNP (100 mA, shortcircuit protection)

IP20 IP20

11 11

N0532A N0534A

Accessories
Type Description Order no.

Mounting clamp 34 mm Housing materials: PBT

E10017

Angle bracket for type M12 Housing materials: stainless steel

E10735

www.ifm.com

43

Capacitive sensors

Type

Description

Order no.

Angle bracket for type M18 Housing materials: stainless steel

E10736

Angle bracket for type M30 Housing materials: stainless steel

E10737

Locknut G 1 for mounting adapter Housing materials: PVDF

E11030

Locknut G 1 for mounting adapter Housing materials: POM

E11031

Locknut G 1 for mounting adapter Housing materials: PVDF

E11032

Mounting adapter M30 x 1.5 - G 1 Housing materials: POM / EPDM

E11033

Mounting adapter M30 x 1.5 - G 1 Housing materials: PVDF / EPDM

E11034

Mounting adapter M30 x 1.5 - G 1 Housing materials: PVDF / EPDM

E11036

Protective cover G 1 for mounting adapter Housing materials: PES black transparent

E11078

Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: clamp: diecast zinc / fixture: steel

E20718

Mounting set 18.5 mm Clamp mounting free-standing M10 for type OG, IG, KG Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20870

Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc

E20873

Mounting set 30.2 mm Clamp mounting free-standing M12 for type OI, II, KI Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20874

Mounting adapter M18 x 1 - G Housing materials: PVDF

E43901

www.ifm.com

44

Capacitive sensors

Type

Description

Order no.

Locknut G for mounting adapter Housing materials: PVDF

E43903

Mounting adapter for free-standing mounting for type KQ Housing materials: adapter: PBT / inserts: brass / screw: steel galvanised Pack quantity: 1

E12153

Wiring diagrams
1 3 5 7

BN BK BU

L+

1
4

L+

BN

L1 L+ N L

BN

BU

BU

BN BK BU

L+

BN

L1 L+ N L

L1 L+ N L

BN

BU
GN/YE

BU

11
AC; DC NPN 1 4 3 L L+ 1 4 3 L L+ 1 2 3 4 5 1 2 L+ N L+ L1 L AC; DC NPN 1 2 3 4 5 1 2 3 L 4 5 L L+ L1 L N L+

DC PNP

DC PNP

10
1 2 3 4 5 L 1 2 3 4 5 L

3 4 5 L+

L+

12

BN BK BU

L+

BN BK

L+

BU

www.ifm.com

45

Capacitive sensors

Scale drawings - CAD download: www.ifm.com 1


18 81 59 LED pot. 14 2 13,4

6
48 43,7 33

M30 x1,5

20

36

5,5 3 2 3,2

1: Programming buttons, 2: sensing face 7


90 77 60 M30 x1,5 M12 x 1
87 77 56

LED (4 x 90)

36

M12 x1

24

1: Programming buttons 3
90 77 60 15 M30 x1,5 M12 x 1

1: LED ring, 2: Programming buttons 8

90 80 61 M30 x1,5 1 2 36 5 90 80 61 1/2" UNF 1 2 36 5


82 40 pot.

LED (4 x 90)

36

1: Programming buttons 4
105 9,3 5,5 40 40 12

1: LED ring, 2: Programming buttons 9

18 27

M12 x 1

65 80

pot. LED

1: LED ring, 2: Programming buttons


65 7,5 16

10 5
LED pot. 84 58
M18 x1
10 20 LED

pot. LED

41

24

www.ifm.com

46

M34 x1,5

M30

M18 x1

Capacitive sensors

Scale drawings - CAD download: www.ifm.com 11


20 112

LED

1: Combicon plug with screw terminals (optional)

www.ifm.com

120

35,5

47

48

Cylinder sensors

Selection chart
T-slot sensors for industrial applications T-slot reed sensors for industrial applications T-slot sensors for hygienic and wet ares Sensors for short-stroke cylinders Sensors for short-stroke cylinders for hygienic and wet areas Non flush C-slot sensors for industrial applications Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
51 51 52 52 52 52 53 53 54 55 55

www.ifm.com

49

Cylinder sensors

Self-clamping fixture for easy adjustment and quick mounting. Convenient: can be easily inserted into the slot from the top. Suitable for almost all C and T slots. Unit versions available with connection cable and M8 / M12 cable plug. Wide selection of adapter accessories.

Cylinder sensors Cylinder sensors are used for position detection of pistons in pneumatic cylinders. They are directly mounted onto the cylinder. The ring magnet attached to the piston is sensed through the housing wall of non-magnetisable material (e.g. aluminium, brass or stainless steel). ifm electronic offers a standard solution for different cylinder types and manufacturers. Operating principle ifms cylinder sensors use state-of-the-art GMR and AMR technology: A GMR element is made up of extremely thin magnetic layers, each separated by a nonmagnetic layer. Without external field they align in an antiparallel manner which results in a defined electrical resistance. If these layers are exposed to a magnetic field, the magnetic layers align in a parallel manner. This results in a large change in resistance that is converted into a switching signal by the internal electronics. An AMR element consists of thin ferromagnetic layers. Electrical resistance is highest without external magnetic fields. The effect of a magnetic field reduces resistance. This change is converted into a switching signal by the internal electronics. Advantage: this method enables exact measurement of even very small changes of the magnetic field where space is extremely limited. This results in a smaller hysteresis and a short travel distance. So, the sensors can be used wherever exact positioning is required (e.g. short-stroke cylinder). Response sensitivity The response sensitivity applies equally to either magnetic polarity and without external field influence. The magnetic flux density in most pneumatic cylinders is between 5 and 25 millitesla (mT). ifm electronics cylinder sensors are factory set so that they detect these magnetic fields safely. Travel distance The travel distance describes the section which is covered by the magnet in the sensing zone. It depends on the strength of the magnet. The short response times of the sensors allow very high travel speeds.

Position sensing: Cylinder sensors monitor the position of the piston in a pneumatic cylinder.

www.ifm.com

50

Cylinder sensors

T-slot sensors for industrial applications


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable with connector 0.3 m Output function


25 x 5 x 6.5 25 x 5 x 6.5 PA (polyamide) PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 10...30 > 10000 > 10000 IP67 IP67 100 200 -25...85 -25...85 1 1 MK5101 MK5106

25 x 5 x 6.5

PA (polyamide)

10...30

> 10000

IP67

100

-25...85

MK5102

25 x 5 x 6.5

PA (polyamide)

10...30

> 10000

IP67

100

-25...85

MK5107

Cable 2 m Output function


25 x 5 x 6.5

DC PNP Wiring diagram no. 2


PA (polyamide) 10...30 > 10000 IP67 100 -25...85 4 MK5100

Cable 2 m Output function


25 x 5 x 6.5

DC PNP/NPN Wiring diagram no. 3


PA (polyamide) 10...30 4000 IP67 100 -25...85 4 MK5103

Cable with connector 0.3 m Output function


25 x 5 x 6.5 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 10000 IP67 200 -25...85 3 MK5108

Cable with connector 0.3 m Output function


25 x 5 x 6.5 PA (polyamide)

DC PNP/NPN Wiring diagram no. 4


10...30 4000 IP67 100 -25...85 1 MK5104

T-slot reed sensors for industrial applications


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable 2 m Output function


30.5 x 5 x 6.5

AC/DC PNP/NPN Wiring diagram no. 5


PA (polyamide) 5...120 1000 IP67 100 -25...70 5 MR0100*

Cable with connector 0.3 m Output function


30.5 x 5 x 6.5 PA (polyamide)

AC/DC PNP/NPN Wiring diagram no. 6


5...60 1000 IP67 100 -25...70 6 MR0107*

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 0,175 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.

www.ifm.com

51

Cylinder sensors

T-slot sensors for hygienic and wet ares


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable 2 m Output function


25 x 5 x 6.5

DC PNP Wiring diagram no. 2


PA (polyamide) 10...30 > 10000 IP67 / IP69K 100 -25...85 4 MK5110

Cable with connector 0.3 m Output function


25 x 5 x 6.5 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 10000 IP67 / IP69K 100 -25...85 7 MK5111

Sensors for short-stroke cylinders


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable 2 m Output function


25 x 5 x 6.5

DC PNP Wiring diagram no. 2


PA (polyamide) 10...30 > 6000 IP67 100 -25...85 8 MK5140

Cable with connector 0.3 m Output function


25 x 5 x 6.5 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 6000 IP67 100 -25...85 9 MK5138

25 x 5 x 6.5

PA (polyamide)

10...30

> 6000

IP67

100

-25...85

10

MK5139

Sensors for short-stroke cylinders for hygienic and wet areas


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable with connector 0.3 m Output function


25 x 5 x 6.5 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 6000 IP67 / IP69K 100 -25...85 11 MK5157

Non flush C-slot sensors for industrial applications


Type Dimensions [mm] Material Ub [V] f [Hz] Protection Iload [mA] Ta [C] Drawing no. Order no.

Cable 2 m Output function


17.5 x 2.8 x 7.7

DC PNP Wiring diagram no. 2


PA (polyamide) 10...30 > 10000 IP67 100 -25...85 12 MK5300

Cable 2 m Output function


17.5 x 2.8 x 7.7

DC NPN Wiring diagram no. 7


PA (polyamide) 10...30 > 10000 IP67 100 -25...85 12 MK5306

www.ifm.com

52

Cylinder sensors

Type

Dimensions [mm]

Material

Ub [V]

f [Hz]

Protection

Iload [mA]

Ta [C]

Drawing no.

Order no.

Cable with connector 0.3 m Output function


17.5 x 2.8 x 7.7 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 10000 IP67 100 -25...85 13 MK5301

Cable with connector 0.3 m Output function


17.5 x 2.8 x 7.7 PA (polyamide)

DC NPN Wiring diagram no. 8


10...30 > 10000 IP67 100 -25...85 13 MK5307

Cable with connector 0.3 m Output function


17.5 x 2.8 x 7.7 PA (polyamide)

DC PNP Wiring diagram no. 1


10...30 > 10000 IP67 100 -25...85 14 MK5302

Accessories
Type Description Order no.

Fixing strap for clean-line cylinders Piston diameter 8...12 mm Piston diameter 8...12 mm for type MKT Housing materials: stainless steel

E11816

Fixing strap for clean-line cylinders Piston diameter 16...20 mm Piston diameter 16...20 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11817

Fixing strap for clean-line cylinders Piston diameter 25...32 mm Piston diameter 25...32 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11818

Fixing strap for clean-line cylinders Piston diameter 40 mm Piston diameter 40 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11819

Fixing strap for clean-line cylinders Piston diameter 50 mm Piston diameter 50 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11820

Fixing strap for clean-line cylinders Piston diameter 63 mm Piston diameter 63 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11821

Fixing strap for clean-line cylinders Piston diameter 80 mm Piston diameter 80 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11822

Fixing strap for clean-line cylinders Piston diameter 100 mm Piston diameter 100 mm for type MKT Housing materials: adapter: PA / Fixing strap: stainless steel

E11823

Adapter for clean-line cylinders for types MKT (T-slot cylinder sensors) Housing materials: stainless steel

E11877

www.ifm.com

53

Cylinder sensors

Type

Description

Order no.

Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 5...11 mm Housing materials: aluminium / screw: stainless steel

E11797

Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 9...15 mm Housing materials: aluminium / screw: stainless steel

E11799

Adapter for tie rod / integrated profile cylinders for types MKT (T-slot cylinder sensors) Clamping range 14...20 mm Housing materials: aluminium / screw: stainless steel

E11801

Adapter for trapezoidal slot cylinders for types MKT (T-slot cylinder sensors) Housing materials: aluminium alloy / set screw: stainless steel

E11796

T-slot adapter for C-slot sensor for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders for types MKC (height 5 mm) Housing materials: diecast zinc / fixing element: stainless steel

E11928

T-slot adapter for C-slot sensor for types MKC (C-slot cylinder sensor) for installation in T-slot cylinders for types MKC (height 7.7 mm) Housing materials: diecast zinc / fixing element: stainless steel

E11914

T-slot cylinder memorisation block for types MKT (T-slot cylinder sensors) Housing materials: PA / stainless steel

E11798

C-slot cylinder memorisation block for types MKC (C-slot cylinder sensors) Housing materials: PA / stainless steel

E12004

Clip for types MKT (T-slot cylinder sensors) Piston diameter 16 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11958

Clip for types MKT (T-slot cylinder sensors) Piston diameter 20 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11959

Clip for types MKT (T-slot cylinder sensors) Piston diameter 25 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11960

Clip for types MKT (T-slot cylinder sensors) Piston diameter 12 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11961

Clip for types MKT (T-slot cylinder sensors) Piston diameter 16 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11958

Clip for types MKT (T-slot cylinder sensors) Piston diameter 20 mm Housing materials: POM / fixture: aluminium / screw: stainless steel

E11959

www.ifm.com

54

Cylinder sensors

Wiring diagrams
1 3 5 7

1 4 3

L+

BN

L+

BN

L1 L+ N L

BN BK BU

L+

BU

BU

BN BK BU

L+

L+

L1 L+ N L

1 4 3

L+

Scale drawings - CAD download: www.ifm.com 1


37 M8x1 1 25 5 LED 6,5
5,7

5
1

6,5 5

5,1 2

30,5

5,1

1: Fastening clamp, 2: sensing face 2


41,5 M8x1 1 25 5 LED 6,5

1: Fastening clamp 6
55 5,7 M12 x1 1

6,5 5

5,1 2

30,5

5,1

1: Fastening clamp, 2: sensing face 3


55
M12 x1

1: Fastening clamp 7
1 25
5

LED 6,5

55

1 25

LED 6,5

M12 x1

5,1 2

5,1 2

1: Fastening clamp, 2: sensing face 4


1 25 5 LED 6,5

1: Fastening clamp, 2: sensing face 8


1 25 5 LED 6,5

5,1 2
2

5,1

1: Fastening clamp, 2: sensing face

1: Fastening clamp, 2: sensing face

www.ifm.com

55

Cylinder sensors

Scale drawings - CAD download: www.ifm.com 9


37 M8x1 1 25 5 LED 6,5 17,5

12
7,7 LED 4,2 2,8 1 2 4,8

5,1 2

1: Fastening clamp, 2: sensing face 10


55 M12 x1 1 25 5 LED 6,5

1: Fastening clamp, 2: sensing face 13


5,1 7,7 17,5 LED 2,8 1 2 37 4,2 4,8

1: Fastening clamp, 2: sensing face 11


55 M12 x1 1 25 5 LED 6,5 M8x1

5,1 2

1: Fastening clamp, 2: sensing face 14


7,7 17,5 LED 41,5 M8x1 4,2 2,8 1 2 4,8 L

1: Fastening clamp, 2: sensing face

1: Fastening clamp, 2: sensing face

www.ifm.com

56

Cylinder sensors

57

58

Safety technology

Selection chart
Fail-safe inductive sensors, 2 x OSSD, to IEC62061 SILcl 2 and ISO13849-1 PL d Safety relays for fail-safe sensors Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
61 61 61 61 62

www.ifm.com

59

Safety technology

Certified to IEC 61508,SIL 2 / SIL 3 and ISO 13849-1 PL d / e. Safety monitoring of persons and machines. No coded target required for electronic fail-safe sensors. Connection of the sensors to safety PLCs, bus systems and switching devices possible. Series connection of sensors and contacts.

Safety technology Safety technology in automation has a share of the responsibility for safe humanmachine interaction. Fail-safe sensors with safety functions are an important part of a safety system for persons and machines. For the first time, the operating principle and thus the advantages of inductive sensors can also be used for safety applications. Direct detection of metal solves new applications. Up to now magnetic or mechanical counterparts had to be considered in the design. The wear-free non-contact sensing principle and a high protection rating ensure high plant uptime. Connection and evaluation No special demands such as shielding, twisted cables or laying separately, are made on the socket. The sensor is directly connected to existing PLCs or logic modules using common existing unshielded 4-pole cables. The input and output signals of the sensors correspond to DIN EN 61131-2. They are therefore fully compatible with the inputs and outputs of a PLC. Connection to ifm safety relays, AS-i Safety at Work, PROFIsafe, Interbus Safety bus systems or safe PLCs and logic modules is equally simple. For the unit family with dynamic pulse detection the corresponding software modules are required. The fail-safe sensors with 2 x PNP output can be connected to approved two-channel safety relays without cross-monitoring that are suitable for plus-switching noncontact guards. The safety relays from ifm electronic enable functionalities such as two-hand controls to EN 574 or connection of e-stop devices to DIN EN 574-5-1 without extra cost. Operating principle of intelligent electronic fail-safe sensors A magnet or coded target is no longer necessary for the function of the fail-safe sensor. The fail-safe inductive sensor detects metals such as stainless steel or mild steel. The fail-safe sensor operates with an enable zone which is monitored for target position and dwell time.
Limitation of the axis areas of a robot monitored by the GG505S.

Connection of the sensors to safety plcs, bus systems and relays possible.

www.ifm.com

60

Safety technology

Fail-safe inductive sensors, 2 x OSSD, to IEC62061 SILcl 2 and ISO13849-1 PL d


Type Length [mm] Enable zone [mm] Housing material Ub DC [V] Protection Response time on removal / approach [ms] Drawing no. Order no.

M12 connector Wiring diagram no. 1


70 0.5...4 nf high-grade st. steel / PBT 19.2...30 IP 65 / IP 67 < 20 / < 200 1 GF711S

70

1...8 nf

high-grade st. steel / PBT

19.2...30

IP 65 / IP 67

< 20 / < 200

GG711S

70

1...15 nf

high-grade st. steel / PBT

19.2...30

IP 65 / IP 67

< 20 / < 200

GI711S

f = flush / nf = non flush Safety relays for fail-safe sensors


Type Ub [V] 24 DC (19.2...30 DC) Sensor input / output 1/2 Safetyrelated output 2 Signal contacts (NC) 1 Feedback contacts Response time [ms] < 180 Off delay [ms] Drawing no. 4 Order no.

G1501S

24 DC (19.2...30 DC)

1/2

< 160

0...10

G1502S

24 DC (19.2...30 DC)

1/2

< 100

G1503S

Accessories
Type Description Order no.

Combicon connector with screw terminals 4-pole Housing materials: PA / current carrying parts: copper alloy tin-plated Pack quantity: 5

E11929

Wiring diagrams
1

1 2 3 4

L+ (BN) A1 (WH) L (BU)

+24 V IN1 GND IN2

A2 (BK)

www.ifm.com

61

Safety technology

Scale drawings - CAD download: www.ifm.com 1


70 59 45 M12 x1

5
50 105

5 M12 x1 4

LED

17
35,5 114

2
70,5 57 35 M12 x1

LED

10 M18 x1 4

LED 2 x 180

24

6
25 105

3
70 57 45 35,5 100 M30x1,5 LED 15 M12x1

LED 4 x 90

36

4
25 105

1: screw terminal (supplied)

LED

1: Combicon connector with screw terminals

www.ifm.com

62

35,5

100

Safety technology

63

64

Valve sensors

Selection chart
Sensors for industrial applications Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
67 67 67 67

www.ifm.com

65

Valve sensors

Dual inductive feedback sensors for valves and actuators. Straightforward fit to standard actuators. Compact, weatherproof and low maintenance. Optional back wiring option for local solenoid control. Versions for network, hazardous area and conventional wiring.

Valve sensors In industrial processes where liquids, air or gases are used valves are needed for dosing and control. There is a wide variety of valve types; butterfly or ball valves being the most common quarter-turn types. These valves are seldom operated manually. Pneumatic valve actuators are normally used for mechanical positioning. The valve position must be monitored electronically. Mechanical switches are still often used for position feedback on the actuator shaft. For other solutions several proximity sensors are used together with a switch target for position detection. Disadvantage: Mounting is mechanically complex. During switch mounting the signal wires can be reversed when they are connected in the top-mounted junction box. Where there are temperature fluctuations condensing humidity leads to corrosion and thus malfunction. Operating principle An innovative design eliminates the disadvantages of these conventional solutions. In 1992 ifm electronic developed a standard which is now used by many leading actuator manufacturers. A round switch target, known as a puck, with two metal screws offset by 90 is mounted on the actuator shaft. The screws are located at a different height. A compact dual proximity switch (type IND) with two integral sensors detects the upper or lower metal screw depending on the valve position and thus the two switch positions. Due to the simple construction the system operates safely with no wear at all. It is virtually resistant to external influence and meets the protection rating IP 67. Under certain conditions the unit can even be self-cleaning. The sensors are also resistant to mechanical stress such as vibration and shock. Special design AS-i (T5) An extended design is the series T5. In addition to the inductive dual sensor, the unit provides an integrated connection for the solenoid valve. The connection to the control unit is made via a two-wire AS-i cable. The asset: Up to 30 other units can be connected to this line and separately controlled via the AS-i master.

Feedback: Monitoring of pneumatic and manual valves must be possible.

www.ifm.com

66

Valve sensors

Sensors for industrial applications


Type Dimensions [mm] Sensing range [mm] Material Ub [V] Protection f AC / DC [Hz] Iload AC / DC [mA] Drawing no. Order no.

Terminals Output function


33 x 60 x 92 4 nf

DC PNP Wiring diagram no. 1


PA (polyamide) 10...30 IP67 500 100 1 IN5409

f = flush / nf = non flush Accessories


Type Description Order no.

Cable gland M20 x 1.5 Housing materials: PA 6.6

E12208

Protective cap M20 x 1.5 Housing materials: PA 6.6

E12209

Wiring diagrams
1

1 2 4 2: 4: A1 A2 3

L+

5 6

IN + IN OUT + OUT -

7
8

1: solenoid valve

Scale drawings - CAD download: www.ifm.com 1


60 92

6,3

18,8

7,5 60 M20x1,5 5,5 30

1: sensor 1, 2: sensor 2, 3: LED OUT 1, 4: LED OUT 2

www.ifm.com

33

67

68

Photoelectric sensors infrared / redlight

Selection chart
Cylindrical housing OG (M18) BasicLine DC Cylindrical housing OG (M18) PerformanceLine DC Cylindrical housing OG (M18) BasicLine with lateral sensing face Cylindrical housing OG (M18) WetLine for hygienic and wet areas OG housing with rectangular housing Cylindrical housing OG (M18) BasicLine AC/DC Rectangular housing OH for industrial applications Rectangular housing OJ PerformanceLine, lateral sensing face Rectangular housing OL for industrial applications Rectangular housing O7 BasicLine Rectangular housing O5 BasicLine Rectangular housing O5 PerformanceLine Rectangular housing O4 BasicLine Rectangular housing O4 PerformanceLine Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
71 71 72 72 72 73 73 74 74 75 75 75 76 76 76 77 77 77 79 79 80

www.ifm.com

69

Photoelectric sensors infrared / redlight

Photocells for general purposes and for harsh environments. Visible red and infrared light sources. Long ranges and accurate background suppression. Choice of standard industrial and high performance units. Accessories for simple fitting and extra mechanical protection.

Photoelectric sensors: infrared / redlight Automation technology can no longer be imagined without photoelectric sensors as artificial eyes. They are used where safe and non-contact detection of the exact position of objects is required. The material of the objects to be detected is of no importance. Compared to proximity sensors photoelectric sensors have a much higher sensing zone. Through-beam sensors A through-beam sensor is distinguished by a long range. The system consists of two separate components: a transmitter and a receiver. The light only travels one way (from the transmitter to the receiver). Adverse effects in the applications, such as dust in the air, dirt on the lenses, steam or mist do not immediately interfere with the system. This is called a high insensitivity to dirt or a high excess gain. Retro-reflective sensors For a retro-reflective sensor the transmitter and receiver are incorporated into one housing. By means of a reflector the transmitted light is returned to the receiver. An object in the beam path interrupts the beam and triggers a switching operation. Retro-reflective sensors without polarisation filter operate in the infrared area, systems with polarisation filter with visible red light. Compared to through-beam sensors, retro-reflective sensors have an average excess gain. Diffuse reflection sensors A diffuse reflection sensor is used for the direct detection of objects. Transmitter and receiver are incorporated into one housing. The transmitter emits light which is reflected by the object to be detected and seen by the receiver. This system evaluates the reflected light of an object. Reflectors are not necessary for operation. Fixing options ifm electronic offers a complete component system of easy-to-use mounting sets. The solutions consist of a clamp which is fastened with only one screw, keeps the sensors safely in place and at the same time guarantees free movement in all axes.

The reflector reflects the light beam: For a retro-reflective sensor transmitter and receiver are integrated into one housing.

Artificial eyes: Photoelectric sensors are used to detect positions in automation technology.

www.ifm.com

70

Photoelectric sensors infrared / redlight

Cylindrical housing OG (M18) BasicLine DC


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGE M18 x 1 M12 connector plastics DC


Receiver 8m D PNP 10...30 1 1 OGE100

Through-beam sensor Type OGS M18 x 1 M12 connector metal DC


Transmitter 8m 600 10...30 2 1 OGS100

Through-beam sensor Type OGE M18 x 1 M12 connector high-grade stainless steel DC
Receiver 20 m D PNP 10...36 1 2 OGE200

Through-beam sensor Type OGS M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 20 m 800 10...36 2 2 OGS200

Retro-reflective sensor Type OGP M18 x 1 M12 connector plastics DC


Polarisation filter 0.05...2.5 m 200 D PNP 10...30 1 1 OGP100

Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter Polarisation filter 0.03...4 m 0.03...4 m 160 160 D PNP H PNP 10...36 10...36 1 3 2 2 OGP200 OGP201

Diffuse reflection sensor Type OGT M18 x 1 M12 connector plastics DC


Diffuse reflection sensor 10...400 mm 25 H PNP 10...30 1 3 OGT100

Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 15...250 mm 15 H PNP 10...36 1 4 OGH200

Cylindrical housing OG (M18) PerformanceLine DC


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGS M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 25 m 1000 10...36 2 5 OGS500

Through-beam sensor Type OGE M18 x 1 M12 connector high-grade stainless steel DC
Receiver 25 m H/D PNP 10...36 1 6 OGE500

www.ifm.com

71

Photoelectric sensors infrared / redlight

Type

Operating principle

Sensing range

Spot at max. range [mm]

Output H = light-on D = dark-on

Ub

Wiring diagram no.

Drawing no.

Order no.

[V]

Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.03...5 m 200 H/D PNP 10...36 1 6 OGP500

Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 15...300 mm 25 H/D PNP 10...36 1 6 OGH500

Cylindrical housing OG (M18) BasicLine with lateral sensing face


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGS M12 connector high-grade stainless steel DC


Transmitter 9m < 3000 10...30 2 7 OG5129

Through-beam sensor Type OGE M12 connector high-grade stainless steel DC


Receiver Receiver 9m 9m H PNP D PNP 10...30 10...30 4 5 7 7 OG5127 OG5128

Retro-reflective sensor Type OGP M12 connector high-grade stainless steel DC


Polarisation filter Polarisation filter 3m 3m < 96 < 96 H PNP D PNP 10...30 10...30 4 5 7 7 OG5125 OG5126

Diffuse reflection sensor Type OGH M12 connector high-grade stainless steel DC
Background suppression Background suppression 100 mm 200 mm < 16 < 28 H PNP H PNP 10...30 10...30 4 4 8 8 OG5123 OG5124

Cylindrical housing OG (M18) WetLine for hygienic and wet areas


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Retro-reflective sensor Type OGP M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.03...4 m 160 D PNP 10...36 1 2 OGP300

Diffuse reflection sensor Type OGH M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 100 mm 8 H PNP 10...36 1 9 OGH300

www.ifm.com

72

Photoelectric sensors infrared / redlight

OG housing with rectangular housing


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGS-Cube M12 connector high-grade stainless steel DC


Transmitter 20 m 800 10...30 2 10 OGS280

Through-beam sensor Type OGE-Cube M12 connector high-grade stainless steel DC


Receiver Receiver 20 m 20 m D PNP H PNP 10...30 10...30 6 3 10 10 OGE280 OGE281

Retro-reflective sensor Type OGP-Cube M12 connector metal DC


Polarisation filter Polarisation filter Polarisation filter 0.1...4 m 0.1...4 m 0.1...4 m 160 160 160 D PNP H PNP D NPN 10...30 10...30 10...30 6 3 7 10 10 10 OGP280 OGP281 OGP282

Diffuse reflection sensor Type OGH-Cube M12 connector metal DC


Background suppression Background suppression Background suppression 100 mm 15...200 mm 15...200 mm 7 13 13 H PNP H/D PNP H/D NPN 10...30 10...30 10...30 3 1 8 10 11 11 OGH280 OGH580 OGH581

Cylindrical housing OG (M18) BasicLine AC/DC


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGS M18 x 1 1/2 connector plastics AC/DC


Transmitter 15 m 2000 20...250 9 12 OG0030

Through-beam sensor Type OGE M18 x 1 1/2 connector plastics AC/DC


Receiver 15 m D AC/DC 20...250 10 12 OG0039*

Retro-reflective sensor Type OGP M18 x 1 1/2 connector plastics AC/DC


Polarisation filter 3m 262 D AC/DC 20...250 10 12 OG0033*

Diffuse reflection sensor Type OGT M18 x 1 1/2 connector plastics AC/DC
Diffuse reflection sensor 1...600 mm < 169 H AC/DC 20...250 10 12 OG0035*

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.

www.ifm.com

73

Photoelectric sensors infrared / redlight

Rectangular housing OH for industrial applications


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OHS Cable with connector 0.2 m plastics DC


Transmitter 1.2 m 10 10...30 2 13 OH5012

Through-beam sensor Type OHE Cable with connector 0.2 m plastics DC


Receiver 1.2 m D PNP 10...30 6 13 OH5003

Retro-reflective sensor Type OHP Cable with connector 0.2 m plastics DC


Polarisation filter 0.8 m 10 D PNP 10...30 6 14 OH5011

Diffuse reflection sensor Type OHN Cable with connector 0.2 m plastics DC
Diffuse reflection sensor 2...50 mm 3.5 H PNP 10...30 3 15 OH5005

Diffuse reflection sensor Type OHH Cable with connector 0.2 m plastics DC
Background suppression 1...30 mm 4.5 H PNP 10...30 3 15 OH5007

Rectangular housing OJ PerformanceLine, lateral sensing face


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OJE M8 connector plastics DC


Receiver 10 m H/D NPN 10...30 11 16 OJ5032

Retro-reflective sensor Type OJP M8 connector plastics DC


Polarisation filter 0...2 m 64 H/D NPN 10...30 11 16 OJ5027

Diffuse reflection sensor Type OJB M8 connector plastics DC


Diffuse reflection sensor Diffuse reflection sensor 1...600 mm 1...1000 mm 60 150 H/D NPN H/D PNP 10...30 10...30 11 12 17 17 OJ5023 OJ5071

Through-beam sensor Type OJS M8 connector plastics DC


Transmitter 10 m 1000 10...30 2 18 OJ5130

Through-beam sensor Type OJE M8 connector plastics DC


Receiver 10 m H/D PNP 10...30 12 18 OJ5131

www.ifm.com

74

Photoelectric sensors infrared / redlight

Type

Operating principle

Sensing range

Spot at max. range [mm]

Output H = light-on D = dark-on

Ub

Wiring diagram no.

Drawing no.

Order no.

[V]

Retro-reflective sensor Type OJP M8 connector plastics DC


Polarisation filter 0...2 m 64 H/D PNP 10...30 12 18 OJ5126

Diffuse reflection sensor Type OJB M8 connector plastics DC


Diffuse reflection sensor 1...600 mm 60 H/D PNP 10...30 12 19 OJ5122

Diffuse reflection sensor Type OJH M8 connector plastics DC


Background suppression 15...400 mm < 18 H/D PNP 10...30 12 20 OJ5148

Rectangular housing OL for industrial applications


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OLS Terminals plastics AC/DC


Transmitter 25 m < 2500 20...250 13 21 OL0006

Through-beam sensor Type OLE Terminals plastics AC/DC


Receiver 25 m H/D relay 20...250 14 21 OL0007

Retro-reflective sensor Type OLP Terminals plastics AC/DC


Polarisation filter 0.3...5 m 250 H/D relay 20...250 14 22 OL0004*

Diffuse reflection sensor Type OLT Terminals plastics AC/DC


Diffuse reflection sensor 1...1000 mm < 300 H/D relay 20...250 14 21 OL0005*

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Rectangular housing O7 BasicLine
Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type O7S Cable with connector 0.2 m plastics DC


Through-beam sensor 0...1.5 m 90 10...30 2 23 O7S200

www.ifm.com

75

Photoelectric sensors infrared / redlight

Type

Operating principle

Sensing range

Spot at max. range [mm]

Output H = light-on D = dark-on

Ub

Wiring diagram no.

Drawing no.

Order no.

[V]

Through-beam sensor Type O7E Cable with connector 0.2 m plastics DC


Through-beam sensor 0...1.5 m D PNP 10...30 6 24 O7E200

Retro-reflective sensor Type O7P Cable with connector 0.2 m plastics DC


Polarisation filter 0.03...1 m 55 D PNP 10...30 6 25 O7P200

Diffuse reflection sensor Type O7H Cable with connector 0.2 m plastics DC
Background suppression Background suppression Background suppression 1...30 mm 0...50 mm 0...100 mm 2.5 2.5 7 H PNP H PNP H PNP 10...30 10...30 10...30 3 3 3 26 26 26 O7H200 O7H202 O7H204

Rectangular housing O5 BasicLine


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type O5S M12 connector plastics DC


Transmitter 20 m 500 10...36 2 27 O5S200

Through-beam sensor Type O5E M12 connector plastics DC


Receiver 20 m D PNP 10...36 6 27 O5E200

Retro-reflective sensor Type O5P M12 connector plastics DC


Polarisation filter 0.1...7 m 175 D PNP 10...36 6 28 O5P200

Diffuse reflection sensor Type O5H M12 connector plastics DC


Background suppression 50...1400 mm 50 H PNP 10...36 3 29 O5H200

Rectangular housing O5 PerformanceLine


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Diffuse reflection sensor Type O5H M12 connector plastics DC


Background suppression 50...1800 mm 50 H/D PNP 10...36 1 30 O5H500

www.ifm.com

76

Photoelectric sensors infrared / redlight

Rectangular housing O4 BasicLine


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Retro-reflective sensor Type O4P M12 connector plastics DC


Polarisation filter 0.3...18 m 500 D PNP 10...36 6 31 O4P200

Rectangular housing O4 PerformanceLine


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type O4S M12 connector plastics DC


Transmitter 80 m 2400 10...36 2 32 O4S500

Through-beam sensor Type O4E M12 connector plastics DC


Receiver 80 m H/D PNP 10...36 1 33 O4E500

Retro-reflective sensor Type O4P M12 connector plastics DC


Polarisation filter 0.3...22 m 660 H/D PNP 10...36 1 34 O4P500

Diffuse reflection sensor Type O4H M12 connector plastics DC


Background suppression 100...2600 mm 50 H/D PNP 10...36 1 35 O4H500

Accessories
Type Description Order no.

Prismatic reflector 25 mm round fixing by screw for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU Housing materials: plastics

E20953

Prismatic reflector 35 mm round fixing by screw for type OA, OC, OE, OF, OG, OI, OM, OR, OS, OT, OU Housing materials: plastics

E20954

Prismatic reflector 42 mm round for type O5P, OA, OC, OE, OF, OG, OH, OI, OJ, OL, OM, OR, OS, OT, OU Housing materials: plastics

E20004

Prismatic reflector 50 mm round fixing by screw for type OA, OC, OE OF, OG, OH, OI, OJ, OM, OR, OS, OS, OT, OU Housing materials: plastics

E20956

Prismatic reflector 80 mm round for type O4P, O5P, OG, OJ, OA, OC, OE OF, OH, OI, OM, OR, OS, OT, OU Housing materials: plastics

E20005

www.ifm.com

77

Photoelectric sensors infrared / redlight

Type

Description

Order no.

Mounting set for reflector 25 mm Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20903

Mounting set for reflector 35 mm Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20907

Mounting set for reflector 50 mm Clamp mounting free-standing M10 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20911

Mounting set for reflector 80 mm Clamp mounting free-standing M12 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20915

Reflective tape for retro-reflective sensors with polarisation filter TS-02 50 x 1000 mm Housing materials: plastics

E21015

Mounting set 12.2 mm Clamp mounting rod mounting 10 mm for type OF, IF Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: diecast zinc

E21200

Protective bracket for free-standing and rod mounting 18 mm Clamp mounting Housing materials: stainless steel 316L / 1.4404

E21125

Protective bracket for free-standing and rod mounting 18 mm with end stop Mounting clamp Clamp mounting Housing materials: Mounting clamp: PC black / Angle bracket: stainless steel 316L / 1.4404

E21126

Angle bracket for type M18 Housing materials: stainless steel

E10736

Basic clip OJ Housing materials: high-grade stainless steel

E20965

Swivel-mount clip for type OJ Housing materials: diecast zinc

E20974

Angle bracket for type OJ Housing materials: high-grade stainless steel

E20984

Mounting set OJ for side lens Clamp mounting free-standing M8 Housing materials: fixture: stainless steel 316Ti / 1.4571 / clamp: stainless steel

E20969

Mounting set O7 Clamp mounting rod mounting 10 mm Housing materials: fixture: stainless steel / clamp: stainless steel / screw: stainless steel / Nut: stainless steel

E21237

www.ifm.com

78

Photoelectric sensors infrared / redlight

Type

Description

Order no.

Angle bracket for type O5 Housing materials: stainless steel 316Ti / 1.4571

E21087

Mounting set Clamp mounting with protective cover free-standing M10 for type O5 Housing materials: stainless steel 316Ti / 1.4571 / clamp: diecast zinc

E21084

Dovetail clamp for type DTS, O4, O5 Housing materials: AlMgSi0.5

E21088

Angle bracket O4 for type O4 Housing materials: stainless steel 316L / 1.4404

E21120

Angle bracket O4 for type O4 Housing materials: stainless steel 316L / 1.4404

E21117

Wiring diagrams
1 5
1 L+

13

1
4
3

L+

4 2 n.c.

L1

L+

L1 L+

3
L

N L

N L

10

14
1 2 3 4 L1 L+ N L

L+

1 4

L+

L1 L+ N L

11
1
L+
L+

1 4 3

L+

1 4

4
2
2: Teach

4
1 4 2 n.c. 3 L L+

12
1 L+
L+

1 4 3

2
4

2: Teach

www.ifm.com

79

Photoelectric sensors infrared / redlight

Scale drawings - CAD download: www.ifm.com 1


LED

7
44 34 31 27,5

8,2

M18 x1

14,5
16

M12 x1

M18 x1

4 24

34 59,3 70,1

M12 x1 LED 4 x 90

24

2 8
60 49 47 40
M18 x1 13,6

M12 x1

M18 x1

9,7 19 27 62 64 4
24

LED 4 x 90

24

3
1 LED
44 34 31 6,5 21,4

29

75

M12 x1

LED 4 x 90

9
72 61 59 44

M12 x1

M12 x1

24

1: with pot. 4
1 72 61 59 50 44

4
LED 4 x 90

24

10
35,4 15,9 11,5
M18 x1
LEDs

18

M12 x1

52 24,1

M18 x1

4
LED 4 x 90

24

3,3

24

1: with pot. 5 11
72 61 59 34

M12 x1

35,4 15,9 11,5 M18 x1

18

M12 x1

52 24,1

M18 x1

4
LED 4 x 90

LEDs

24

1 3,3 24

6
72 61 59 34

M12 x1

1: setting pushbuttons

M12 x1

4
LED 4 x 90

24

1: Programming buttons

www.ifm.com

80

M18 x1

38

38

M18 x1

M18 x1

Photoelectric sensors infrared / redlight

Scale drawings - CAD download: www.ifm.com 12


86 76 64 53

17
1 LED 11 7,6 16,6 35 3,1 3,2 M8x1 3,1 8,8 9 LED 3,9 7,6 6,4 12,5 9,6 1 20,6 25,1 3,2 15 4 LED

LED " 20UNF

1 5,2 M18 x1 24 LED

1 2

4 1 24

1: pushbutton 13

2,9

1: pushbutton 18

14
7,6 LED
3,9

12,5 9,6

24

LED 5

LED 11 8,2

6,4

5,7 20,6 25,1

3,2

1,8 5,3 19

15

2,9

3,5 8,5

M8x1

15
LED 3,9 7,6 5 7,2 20,6 25,1 12,5 9,6

4
11,6

LED

3,2

1: pushbutton 19
1 1 LED 11

15

2,9

16
1 1 24 LED LED 11 8,2

24

LED
5

35

3,5 8,5

1,8 5,3 19

3,1 3,2

45

M8x1 3,1 8,8


1

4
11,6

LED

9 4

1: pushbutton
1 LED

1: pushbutton

www.ifm.com

7,6 16,6 36,5 43,5


M8x1

35

36,5 43,5

35

45

81

Photoelectric sensors infrared / redlight

Scale drawings - CAD download: www.ifm.com 20


1

24
1 LED 11 26 20,3 2,7 15 LED 9

24

LED
5

9,5 19,5 36,5 43,5

35

1,8 5,3 19

3,5 8,5

M8x1

M3

9 4
11,6

25
15 LED 6,5 9

LED

1: pushbutton 21

26 20,3 2,7

M3

LED 27 10

62 49

LED

26
15 LED 7,8 9

31

75

5,5

M3

1: pushbutton 22
1 LED 27 10
LED

27
1
62 49

18,2 6 17

46,8 6,4

6,5

LED

8,6

50

26 20,3 2,7

7,6

14,1

LED 6

5x9

18

25

13 75

5,5

M12 x1

LED

8,6

50

1: pushbutton 23
15 LED 9

LED 15,4

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.

26 20,3 2,7

M3

www.ifm.com

82

14,1

56 70,3

25

Photoelectric sensors infrared / redlight

Scale drawings - CAD download: www.ifm.com 28


18,2 6 17 46,8 6,4 LED 6 5x9

31
63,8 27 21,1 8,5 7,9 LED 8,5 5x10

36,5

50,9

25

25

40

56 70,3

M12 x1 M12 x1

LED 15,4 LED

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm. 29


46,8 6,4 6 19,5 1 LED 6 5x9

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.


18,2

32
63,8 27
21,1 8,5

29,5

74,4 86,2

40

25

37

56 70,3

25

7,9

LED
8,5

5x10

40

40

M12 x1

1
3 1 10 8

LED

M12 x1 15,4 24,3

1: with pot., 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm. 30
46,8 6,4 6 19,5 1 LED 6 5x9

LED

18,2

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.

25

37

M12 x1

1 LED 15,4 24,3 30,5

1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.

www.ifm.com

56 70,3

25

29,5

74,4 86,2

83

Photoelectric sensors infrared / redlight

Scale drawings - CAD download: www.ifm.com 33


63,8 27 8,5 21,2 7,9 LED 8,5 5x10 27 21,2 8,5 7,9

34
63,8 LED 8,5 5x10

40

40

40

74,4 86,2

M12 x1

M12 x1

2 LED 29,5 38,3 44,5

2 LED 29,5 38,3 44,5

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons 35
63,8 27 25,3 8,5 7,9 LED 8,5 5x10

23,5

40

74,4 86,2

40

1 19,7

M12 x1

2 LED 29,5 38,3 44,5

1: When a M5 mounting screw is used, the max. tightening torque is 2 Nm., 2: Programming buttons

www.ifm.com

84

74,4 86,2

40

Photoelectric sensors infrared / redlight

85

86

Photoelectric sensors laser

Selection chart
Cylindrical housing OG (M18) Laser PerformanceLine Rectangular housing OJ Laser PerformanceLine, lateral sensing face Rectangular housing O1 Laser PerformanceLine with background suppression Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
89 89 89 89 90 90 90

www.ifm.com

87

Photoelectric sensors laser

Safe class 2 laser with visible light for ease of alignment. Detect objects smaller than 1 mm across. Long range versions for measurement up to 60 m. Accurate and repeatable switch point setting. Fine ajustment mounting brackets for easy installation.

Photoelectric sensors: laser Laser systems are used where detection of small objects or precise positioning is required. They are available as through-beam sensors, retro-reflective sensors or diffuse reflection sensors. Laser light consists of light waves of identical length which have a defined phase relation (coherence). This results in an important feature of laser systems, that is the almost parallel light beam. Result: Due to the small angle of divergence long ranges of up to 60 metres can be achieved. The laser spot which is also clearly visible at daylight simplifies the alignment of the system. Apart from the advantages some points have to be taken into account for the selection of the suitable optical system: compared to standard sensors the laser sensors have a reduced temperature range (-10...50 C). In view of the small light spot and the often high ranges the system is more sensitive to vibrations than standard sensors. Mounting aids The ifm laser sensors offer a useful function for easier alignment: The laser power is increased during adjustment: This leads to a particularly bright laser spot which enables safe alignment from a distance even at daylight. How dangerous are laser sensors? Due to the small angle of divergence laser beams are focussed on a small area. The energy and power density on this area is extremely high. ifm laser sensors comply with the European standard EN 60825 or the international standard IEC 60825. These standards describe the operation of laser systems.

Coherent: Laser sensors emit light of a defined wave length and the same phase position.

www.ifm.com

88

Photoelectric sensors laser

Cylindrical housing OG (M18) Laser PerformanceLine


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Through-beam sensor Type OGSL M18 x 1 M12 connector high-grade stainless steel DC
Transmitter 60 m 150 10...36 1 1 OGS700

Through-beam sensor Type OGEL M18 x 1 M12 connector high-grade stainless steel DC
Receiver 60 m H/D PNP 10...36 2 2 OGE700

Retro-reflective sensor Type OGPL M18 x 1 M12 connector high-grade stainless steel DC
Polarisation filter 0.2...15 m 40 H/D PNP 10...36 2 2 OGP700

Diffuse reflection sensor Type OGHL M18 x 1 M12 connector high-grade stainless steel DC
Background suppression 20...200 mm 1.2 H/D PNP 10...36 2 2 OGH700

Rectangular housing OJ Laser PerformanceLine, lateral sensing face


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Diffuse reflection sensor Type OJHL M8 connector plastics DC


Background suppression Background suppression 7...150 mm 15...200 mm 0.8 2x1 H/D PNP H/D PNP 10...30 10...30 3 3 3 4 OJ5158 OJ5154

Rectangular housing O1 Laser PerformanceLine with background suppression


Type Operating principle Measuring range Light spot diameter [mm] Ub Current consumption [mA] Sampling rate / switching frequency [Hz] Drawing no. Order no.

[V]

Optical distance sensor Type O1DL M12 connector metal DC


Background suppression 0.2...10 m 6 10...30 150 5 5 O1D101

Accessories
Type Description Order no.

Prismatic reflector 19 mm round fixing by screw M3 for laser units for type OGPL, OJPL, OLPL Housing materials: screw: stainless steel 316 / 1.4401 / spring washer: stainless steel 316 / 1.4401 / Nut: stainless steel 316 / 1.4401 / front plate: PMMA / base: ABS

E20993

Prismatic reflector 30 x 20 mm angular for laser units for type OGPL, OJPL, OLPL Housing materials: front plate: PMMA / base: ABS

E20994

www.ifm.com

89

Photoelectric sensors laser

Type

Description

Order no.

Prismatic reflector 50 x 50 mm angular for laser sensors and glass / film detection sensors Housing materials: plastics

E20722

Swivel-mount clip for type OJ Housing materials: diecast zinc

E20974

Mounting set Clamp mounting rod mounting 12 mm for type O1D, O2D Housing materials: fixture: stainless steel / clamp: stainless steel / screws: stainless steel / Nut: high-grade stainless steel

E2D101

Wiring diagrams
1 2 3
1
L+

L+

1
4

L+

2
4

2: Teach

Scale drawings - CAD download: www.ifm.com 1


72 61 59 34

3
1 24 LED 5 M18 x1 1 LED 11

M12 x1

9,5 15,5
1,8 5,3 19

4
LED 4 x 90

24 3,5 8,5 M8x1

2
9
72 61 59 34

4
11,6

M12 x1

M18 x1

LED

4
LED 4 x 90

1: pushbutton

24

1: Programming buttons

www.ifm.com

90

36,5 43,5

35

Photoelectric sensors laser

Scale drawings - CAD download: www.ifm.com 4


1

5
1 LED 11

9,5 19,5 36,5 43,5

4,5

24

LED

42 30

45

35

3,5 8,5

1,8 5,3 19

M8x1

M12x1 20 25

4
11,6

LED

1: 4-digit alphanumeric display, 2: Programming buttons 1: pushbutton

www.ifm.com

52

45 59

30

91

92

Photoelectric sensors fibre optics

Selection chart
OOF amplifiers for acrylic fibre optics OBF amplifiers for acrylic fibre optics Acrylic fibre optics for OBF / OOF housings, through-beam system Acrylic fibre optics for OBF / OOF housings, diffuse reflection system Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length Acrylic fibres on a reel for OBF housing Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
95 95 95 95 96 96 96 96 96 97 97 98

www.ifm.com

93

Photoelectric sensors fibre optics

Acrylic and glass fibre optic sensing heads and amplifiers. Can be used in areas where space and access is restricted. Fibres for high temperatures and use with aggressive chemicals. Multi-channel amplifiers with display and logic functions. Simplified wiring and reduced space requirement.

Photoelectric sensors: fibre optics Fully automatic manufacturing machines become more and more compact. Fibre optics are used where mounting space for photoelectric standard sensors is confined. Advantages of these systems: The evaluation electronics and the optoelectronic components are located separately from the sensing surface of the system. Fibre optic sensing heads can therefore be mounted in places where access is difficult. Fibre optics are the best choice, in particular for short ranges. Versions of fibre optic systems Through-beam principle Transmitting and receiving fibre optics are laid separately. The two ends (fibre optic heads) are mounted opposite each other. The light beam interruption is evaluated according to the through-beam principle. The maximum range is 120 cm. Diffuse reflection principle Transmitting and receiving fibres are in one sheath. The sensing head incorporates receiving and transmitting fibre bundles. The ranges of the ifm sensors are max. 70 mm. Applications of fibre optic systems: Confined space The fibre optic head is directly located where sensing takes place, the mating amplifier where sufficient mounting space is available. Detection of minute objects Depending on the type of sensing head and range objects up to 0.5 mm can be detected safely. When the movement of objects is precise, it is possible to detect fine structures, e.g. thread pitches. High temperatures Fibre optics with metal sheath can be used up to 290 C, fibre optics with metal silicone sheath up to 150 C. Chemical resistance Metal silicone sheathed fibre optics are resistant to many aggressive chemicals.
Fibre optic systems can also be mounted in places where access is difficult. Minute objects up to 0.5 mm are detected safely.

www.ifm.com

94

Photoelectric sensors fibre optics

OOF amplifiers for acrylic fibre optics


Type Number of input channels For fibre optics Type of light Sensing range through beam Sensing range diffuse Output H = light-on D = dark-on Ub Drawing no. Order no.

[V]

Type OOF M12 connector plastics DC Wiring diagram no. 1


2 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 1 OO5000

Type OOF M12 connector plastics DC Wiring diagram no. 2


4 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 2 OO5001

Type OOF M16 connector plastics DC Wiring diagram no. 3


6 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 3 OO5002

Type OOF M16 connector plastics DC Wiring diagram no. 4


8 FT-11 red 3.8 m 0...300 mm H/D PNP 12...36 4 OO5003

OBF amplifiers for acrylic fibre optics


Type Number of input channels For fibre optics Type of light Sensing range through beam Sensing range diffuse Output H = light-on D = dark-on Ub Drawing no. Order no.

[V]

Type OBF M12 connector plastics DC Wiring diagram no. 5


1 FT-11 red 0...2 m 0...100 mm H/D PNP/NPN 10...30 5 OBF500

Acrylic fibre optics for OBF / OOF housings, through-beam system


Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 150 / 210 / 800 aluminium Sensing head material Ambient temperature [C] -40...70 PE (polyethylene) 6 E20615 Sheathing material Drawing no. Order no.

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 20 / 25 / 60 aluminium Sensing head material Ambient temperature [C] -40...70 PE (polyethylene) 7 E20639 Sheathing material Drawing no. Order no.

www.ifm.com

95

Photoelectric sensors fibre optics

Acrylic fibre optics for OBF / OOF housings, through-beam system, can be cut to length
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 45 / 80 / 120 aluminium Sensing head material Ambient temperature [C] -40...70 8 E20768 Sheathing material Drawing no. Order no.

PMMA

175 / 370 / 700

aluminium

-40...70

E20767

Acrylic fibre optics for OBF / OOF housings, diffuse reflection system, can be cut to length
Type Fibre optic material Range OB50.. / OBF5.. / OO50.. [mm] PMMA 55 / 110 / 235 aluminium Sensing head material Ambient temperature [C] -40...70 9 E20765 Sheathing material Drawing no. Order no.

Acrylic fibres on a reel for OBF housing


Type Description Order no.

acrylic fibres on a reel 20 m for type OBF Housing materials: PE / Fibre: : PMMA

E20773

acrylic fibres on a reel 50 m for type OBF Housing materials: PE / Fibre: : PMMA

E20774

Accessories
Type Description Order no.

cutter for fibre optics Housing materials: plastics

E20600

Wiring diagrams
1
1 4 2

L+

4: Out 1 2: Out 2

7 3

7: function check

www.ifm.com

96

Photoelectric sensors fibre optics

Wiring diagrams
2
1 4
4: Out 1 2: Out 2 5: Out 3 6: Out 4

4
L+ A E L+
E: Out 1 P: Out 2 S: Out 3 G: Out 4 C: Out 5 T: Out 6 N: Out 7 J: Out 8

6 7 3 L

J O L L

7: function check 3
A E L+
E: Out 1 P: Out 2 S: Out 3 G: Out 4 C: Out 5 T: Out 6

O: function check 5

1 4 2 3

L+

1 2 4

L+

T O L L

O: function check

Scale drawings - CAD download: www.ifm.com 1 2

1: mounting on DIN rail

1: mounting on DIN rail

www.ifm.com

97

Photoelectric sensors fibre optics

Scale drawings - CAD download: www.ifm.com 3 5


15 74

M12 x1

36

1 44 60 LED

3,2

1: mounting on DIN rail, 2: setting pushbuttons 6 1: mounting on DIN rail


M4 M5
40 14,5

15

23

8 1: mounting on DIN rail


10,5 30

www.ifm.com

98

M8

M4

16

Photoelectric sensors fibre optics

99

100

Photoelectric sensors specific systems

Selection chart
Sensors for the detection of transparent objects Sensors for distance and level measurement Sensors for colour detection Safety light grids Accessories Evaluation units light curtains / safety light grids Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
103 103 103 - 104 104 104 104 105 105

www.ifm.com

101

Photoelectric sensors specific systems

High-quality photoelectric sensors for different applications. Excellent price / performance ratio. Extremely compact laser distance sensor with 10 m range. Sensor for the detection of transparent objects (PET, glass, film etc.). Extensive range of system components for easy and safe mounting.

Detection of transparent objects Counting bottles and glasses or the reliable monitoring of film for tear can be performed without problem using specially designed retro-reflective sensors. ifm offers a retro-reflective sensor with a small switching hysteresis, in particular for the detection of transparent objects. Due to the operating principle, retro-reflective sensors have the advantage that the light beam must pass the object to be detected twice. Thus the light is sufficiently weakened to detect a transparent object safely. Precise adjustment is made by means of the Teach button. Distance measurement The continued development of the pmd technology (Photonic Mixer Device) now enables distance measurement to within a millimetre at high ranges using a laser sensor. The efector pmd laser sensor operates to the time-of-flight principle: A light beam is emitted by a transmitting element and reflected to the receiver element by an object. The measured time of flight relates to the distance from the sensor to the object. Traditional time-of-flight sensors use a photodiode as receiver element. Additional electronics is used for signal acquisition and processing. Disadvantage: This sensor design is complex, large in size and therefore often not suitable for industrial position sensing. In comparison, the efector pmd sensors receiver element is a System-on-Chip design: both sensor element and electronics for signal evaluation are integrated on a single silicon chip called a Photonic Mixer Device (PMD). The advantage: The sensor offers a high performance in a compact, industrially compatible housing. efector pmd can be used for level measurement and positioning tasks, for example to position industrial trucks in high bay storage areas and to protect autonomous industrial transport systems against collision.
The efector pmd provides an analogue signal that is proportional to the objectto-sensor distance.

Typical application for contrast sensors: Counting of glass bottles.

www.ifm.com

102

Photoelectric sensors specific systems

Sensors for the detection of transparent objects


Type Operating principle Sensing range Spot at max. range [mm] Output H = light-on D = dark-on Ub Wiring diagram no. Drawing no. Order no.

[V]

Retro-reflective sensor Type OJPG M8 connector plastics DC


Polarisation filter 0.2...1.5 m 64 H/D PNP 10...30 1 1 OJ5186

Retro-reflective sensor Type O5G M12 connector plastics DC


Polarisation filter 0...1.5 m 40 / 80 H/D PNP/NPN 10...36 6 2 O5G500

Sensors for distance and level measurement


Type Operating principle Measuring range Light spot diameter [mm] Ub Current consumption [mA] Sampling rate / switching frequency [Hz] Drawing no. Order no.

[V]

M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC PNP Wiring diagram no. 7
Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D100

M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC NPN Wiring diagram no. 8
Optical distance sensor 0.2...10 m 6 18...30 150 1...50 3 O1D103

M12 connector Output function OUT1: normally open / closed programmable OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scalable) DC PNP Wiring diagram no. 7
Optical distance sensor Optical distance sensor Optical level sensor Optical distance sensor 0.3...6 m 0.2...10 m 0.2...10 m 1...75 m 6 6 6 150 18...30 18...30 18...30 18...30 150 150 150 150 1...33 1...33 1...33 1...33 3 3 3 3 O1D155 O1D105 O1D300 O1D106

Sensors for colour detection


Type Operating principle Measuring range Light spot diameter [mm] Ub Current consumption [mA] Sampling rate / switching frequency [Hz] Drawing no. Order no.

[V]

M12 connector Output function light-on / dark-on programmable DC PNP/NPN Wiring diagram no. 2
Colour sensor 17 mm 2.5 x 6 10...36 50 2000 4 O5C500

M12 connector DC PNP Wiring diagram no. 3


Colour sensor Colour sensor 12.5 mm 60 mm 2x4 13 12...30 12...30 80 80 1000 1000 5 5 OD5005 OD5007

www.ifm.com

103

Photoelectric sensors specific systems

Type

Operating principle

Measuring range

Light spot diameter [mm]

Ub

Current consumption [mA]

Sampling rate / switching frequency [Hz]

Drawing no.

Order no.

[V]

M12 connector DC PNP Wiring diagram no. 4


Colour sensor Colour sensor 12.5 mm 60 mm 2x4 13 12...30 12...30 80 80 300 300 5 5 OD5009 OD5011

M12 connector DC PNP Wiring diagram no. 3


Colour sensor 9 mm 12...30 80 1000 6 OD5013

Safety light grids


Type Number of beams Protected area height [mm] Protected area width [m] Response time [ms] Ub Wiring diagram no. Drawing no. Order no.

[V]

Complies with the requirements: type 4 , SIL 3 , SILcl 3 , PL e M12 connector


2 3 4 510 810 910 0...10 / 3...20 0...10 / 3...20 0...10 / 3...20 2.5 2.5 2.5 24 24 24 5 5 5 7 7 7 OY120S OY121S OY122S

Accessories
Type Description Order no.

Angle bracket for type O5 Housing materials: stainless steel 316Ti / 1.4571

E21087

Prismatic reflector 50 x 50 mm angular for laser sensors and glass / film detection sensors Housing materials: plastics

E20722

Mounting set Clamp mounting rod mounting 12 mm for type O1D, O2D Housing materials: fixture: stainless steel / clamp: stainless steel / screws: stainless steel / Nut: high-grade stainless steel

E2D101

Evaluation units light curtains / safety light grids


Type Description Drawing no. Order no.

Safety relay Muting relay Housing for DIN rail mounting For the connection of safety light curtains / safety light grids with OSSD Safety category type 4 to IEC 61496 for industrial applications

G2001S

www.ifm.com

104

Photoelectric sensors specific systems

Wiring diagrams
1
1
L+

3
1 2
5
L+

4
2
L+

5
1
5 3 Out 1 Out 2 Out 3
L

1 2 3 4 5 6 7 8

OSSD1

L+
OSSD2 K1/K2/Restart SEL_A SEL_B

2
4

2: Teach

Out

4 6 7

2
1 2
5
L+
AT N.C. Out

2: Input AT activation trigger, 5: input External Teach

1: Input AT activation trigger, 5: input External Teach

2: Input AT activation trigger 6


1 2 5 4 3 L n.c. 1 2 5 4 3 L n.c.

L+

L+

1 2 4

L+

1 4 2

L+

4: Out 1 2: Out 2

4: Out 1 2: Out 2

1 2 4 2: Out 2 4: Out 1 3

L+

1 2 4

L+

2: Out 2 4: Out 1

Scale drawings - CAD download: www.ifm.com 1


1 1

2
46,8 6,4 6 19,5 1 LED 6 5x9

24

LED 5

LED 11 8,2

18,2

25

37

1,8 5,3 19

36,5 43,5

3,5 8,5

M8x1 M12 x1

9 4
11,6

1 LED 15,4 24,3 30,5

LED

1: pushbutton

1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm.

www.ifm.com

56 70,3

35

25

105

Photoelectric sensors specific systems

Scale drawings - CAD download: www.ifm.com 3


42 30 4,5

6
119 M5 28 96 80 43

45

45 59

30

M12 x1

M12x1 20 25

1 M12 x1

M5

52

21 30
28 39

14

1: 4-digit alphanumeric display, 2: Programming buttons 4


2
46,8 6,4 6 1 LED 6 5x9
LED

4 3
LED

18,2

25,9 38

25

25

56 70,3

1: fibre optic connection, 2: selection switch color tolerance, 3: programming selector switch, 4: teach button 7

M12 x1 T 51 1 LED 15,4 24,3 30,5 10 R 10

14,5 M5 1,5

1: Programming buttons, 2: When a M5 mounting screw is used, the max. tightening torque is 2 Nm. 5
96 M5 28 80 43

40 20

40

53
102 29,5 10 40 20 M12x1 28 10,5 10 30 28 28 114,5 99 3 5,5

M12 x1

1 M12 x1

M5

21 30

40

53

T: Transmitter, R: Receiver, 1: LED 3 colours (red/green/orange), 2: LED yellow, 3: LED 2 colours (red/green) 8

15

28

39

69

35

LED

4 3
LED

1: lens, 2: selection switch color tolerance, 3: programming selector switch, 4: teach button

www.ifm.com

106

69

Photoelectric sensors specific systems

107

108

Object recognition

Selection chart
Sensors for object recognition with PNP output function Accessories 2D Sensors for 3D object recognition Accessories 3D Scale drawings - CAD download: www.ifm.com

Page
111 111 111 112 112

www.ifm.com

109

Object recognition

2D vision sensor for object recognition. 3D sensor for assessment of distance, level or volume. 3D camera for spatial detection of scenes and objects. Easy, time-saving parameter setting. Robust, industrially compatible housing with integrated lighting.

2D vision sensor for object recognition In automation technology visions sensors are an integral part of assembly and manufacturing tasks as well as quality control and thus increase efficiency. They are cameras with application-specific evaluation, i.e. reliable electronic eyes at a low cost and a high degree of integration. In a robust, industrially compatible housing they combine lighting, lens, camera chip, evaluation and process connections for the integration in the higher-level controller. The application possibilities of efector dualis range from presence, position and orientation monitoring, via sorting and counting tasks to quality control. 3D sensor for assessment of distance, level or volume efector pmd 3d is the first industrial 3D sensor that can assess objects in three dimensions at a glance. Special feature: the time-of-flight measurement and evaluation are integrated on one chip. Each pixel of this chip matrix evaluates its distance to the object. The image of the object on the chip matrix and the respective distance values correspond to a 3D image. This technology enables the detailed assessment of the objects or scenes conditions by means of volume, distance or level detection in three dimensions. Typical applications are completeness checks and level monitoring in the food industry as well as presence and dimension monitoring in conveying. 3D camera for detection in three dimensions of scenes and objects The pmd 3d camera detects scenes and objects in their spatial dimensions at a glance. In contrast to laser scanners it does not require moving components and is thus robust and wear-free. The operating principle is the same as for the 3D sensor. Besides the 3D distance image the camera provides a grey image of the scene. The combination of these images offers integrators the possibility to freely program application-specific tasks by means of a software development kit. This results in lowcost application solutions in the areas of packaging, storage and materials handling, airport logistics, collision avoidance, robotics, monitoring of space and persons.

Set-up in just a few steps: The professional and easy menu guidance allows configuration of the efector dualis to your application in just six operating steps.

www.ifm.com

110

Object recognition

Sensors for object recognition with PNP output function


Type Operating principle Type of light Max. field of view size [mm] Detection rate [Hz] Motion speed (max.) [m/s] Drawing no. Order no.

Type O2D2 metal DC


Object recognition sensor 640 x 480 10 1 1 O2D220

Accessories 2D
Type Description Order no.

Operating software O2D

E2D200

Mounting set O2D, O2M, O2I Clamp mounting rod mounting 12 mm Housing materials: fixture: stainless steel / clamp: stainless steel

E2D110

mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571

E20939

mounting rod 14 / M12 Length: 200 mm angled Housing materials: stainless steel 316Ti / 1.4571

E20941

Cube M12 aluminium profile Housing materials: diecast zinc

E20952

Plastic protective pane for the food industry O2D / O2I Housing materials: housing: diecast zinc black / lens: PMMA

E21166

Patch cable Cross-over patch cable Cable length 5 m

E30112

Socket ifm electronic angled Free from silicone Free from halogen gold-plated contacts M12 connector 5 m Housing materials: PUR

E11232

Sensors for 3D object recognition


Type Operating principle Resolution [pixels] Angle of aperture (horizontal x vertical) [] Lighting Max. sampling rate [Hz] Ub Wiring diagram no. Drawing no. Order no.

[V]

PMD 3D sensor Type O3D M12 connector metal DC


PMD 3D sensor 64 x 48 30 x 40 Infrared LED 20 24 1 2 O3D200

www.ifm.com

111

Object recognition

Accessories 3D
Type Description Order no.

Operating software for PMD 3D sensor O3D

E3D200

Mounting set O3D Clamp mounting rod mounting 14 mm Housing materials: fixture: stainless steel / clamp: stainless steel

E3D103

mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571

E20939

Scale drawings - CAD download: www.ifm.com 1


42 21 1 53,5 2

75

95

21,5

20,5

57 60

45

24,5

120 123,5 137

80

4,3

63,8

19

45

9,5 7

19,7 33 44

16
M12x1 M12x1

18

40 60,5

M12x1 M12x1

1: display, 2: Focus setting, 3: Centre of the lens axes

1: lens, 2: Illumination unit, 3: Display / buttons / LEDs, 4: Focus setting

www.ifm.com

112

94

Object recognition

113

114

Encoders

Selection chart
Incremental encoders with solid shaft Incremental encoders with hollow shaft Absolute multiturn encoders (Profibus) Absolute singleturn - encoders (CANopen) Absolute multiturn - encoders (CANopen) Accessories Scale drawings - CAD download: www.ifm.com

Page
117 117 117 117 118 118 118 - 119

www.ifm.com

115

Encoders

Robust designs. Industrial standard housings. Cable entry for axial and radial use. Designs with integrated bus interface. Hollow shaft encoder for direct mounting on actuators.

Encoders In many manufacturing and production processes they are indispensable as reliable transducers to ensure precise positioning. They convert rotary movement into digital signals. Linear measurement is also possible in conjunction with rack and pinion or measuring wheels. Encoders use the wear-free photoelectric detection. A pulse disc firmly attached to the shaft ensures this detection. Encoders are basically divided into two types: incremental and absolute encoders. Incremental encoders Incremental encoders generate a precisely defined number of pulses per revolution. They are a measure of the angular or linear distance moved. The coded disc is divided into separate segments which are alternately transparent or opaque. An LED emits a parallel-orientated light beam which illuminates all segments of the coded disc. Photo elements receive the modulated light and convert it into two sinusoidal signals. Digitalisation electronics amplify the signals and shape them into square-wave pulse trains which are generated via the line driver in the output. The phase difference between signal A and B, which are phase-shifted by 90 degrees, allows evaluation of the direction of rotation. Absolute encoders Absolute encoders provide an absolute numerical value for each angular position. This code value is available immediately after power is applied. This absolute value makes a reference procedure like the one required for the incremental encoder unnecessary. Absolute encoders are used wherever angular positions have to be allocated to a certain value and where the detection of the present position is absolutely necessary in the case of a power failure. Singleturn and multiturn Singleturn encoders divide a mechanical revolution (0 to 360 degrees) into a certain number of measuring steps. The measuring values are repeated after one revolution. The maximum resolution is 8192. Multiturn encoders, however, do not only detect angular positions but also distinguish between multiple revolutions.
Hollow shaft encoder for direct mounting on the axis.

Linear measurement by means of a counter: rotary movement is converted into digital signals.

www.ifm.com

116

Encoders

Incremental encoders with solid shaft


Type Resolution Ub [V] f [kHz] Iload [mA] Shaft [mm] Ambient temperature [C] Cable entry Drawing no. Order no.

Cable 2 m Output TTL output 20 mA


500 5 300 20 6 -30...100 radial / axially 1 RB1015

Cable 2 m Output HTL-output 50 mA, short-circuit protected < 1 min


125 500 1000 10...30 10...30 10...30 160 160 160 50 50 50 6 6 6 -30...70 -30...70 -30...70 radial / axially radial / axially radial / axially 1 1 1 RB6009 RB6015 RB6029

Cable 2 m Output TTL output 20 mA


500 1024 5 5 300 300 20 20 6 6 -40...100 -40...100 radial / axially radial / axially 2 2 RU1016 RU1025

Incremental encoders with hollow shaft


Type Resolution Ub [V] f [kHz] Iload [mA] Shaft [mm] Ambient temperature [C] Cable entry Drawing no. Order no.

Cable 1 m Output HTL-output 50 mA, short-circuit protected < 1 min


500 1024 10...30 10...30 300 300 50 50 12 H7 12 H7 -40...100 -40...100 radial / axially radial / axially 3 3 RO6344 RO6345

Absolute multiturn encoders (Profibus)


Type Resolution Ub [V] f [kHz] Iload [mA] Shaft [mm] Ambient temperature [C] Cable entry Drawing no. Order no.

Terminals Output Profibus data interface


25 bits 10...30 10 -40...70 4 RM3005

Absolute singleturn - encoders (CANopen)


Type Resolution Ub [V] f [kHz] Iload [mA] Shaft [mm] Ambient temperature [C] Cable entry Drawing no. Order no.

Terminals Output CANopen interface


13 bits 9...36 6 -40...70 5 RN7003

13 bits

9...36

10

-40...70

RN7004

www.ifm.com

117

Encoders

Absolute multiturn - encoders (CANopen)


Type Resolution Ub [V] f [kHz] Iload [mA] Shaft [mm] Ambient temperature [C] Cable entry Drawing no. Order no.

Terminals Output CANopen interface


25 bits 9...36 6 -40...70 5 RM7003

25 bits

9...36

10

-40...70

RM7004

Accessories
Type Description Order no.

Angle bracket for encoders for type RB, RC, RU, RN, RM Housing materials: aluminium black anodised

E60033

Angle bracket for encoders for type RM, RMU, RN, RU Housing materials: aluminium black anodised

E60034

Flexible coupling with clamp connection [KV] 6 mm / 6 mm Housing materials: aluminium

E60064

Flexible coupling with adjusting screw connection [SV] 6 mm / 6 mm Housing materials: aluminium

E60063

Flexible coupling with adjusting screw connection [SV] 6 mm / 10 mm Housing materials: aluminium

E60028

Scale drawings - CAD download: www.ifm.com 1


1 25

2
1
30

37,5

15 2 6

2 42

46,70,5

10 4

18 35

6
6

12 0

1: reference mark, 2: M3 5 mm deep 1: reference mark, 2: M4 5 mm deep

3 3

www.ifm.com

118

50 h7 58
4,5

Encoders

Scale drawings - CAD download: www.ifm.com 3


47,20,5 34,5

5
1 42 80 12 H7
120

20

3,2

10,5 4

63 68

28 58

6 24

24

TX 8
20

3 3 18

4
1 48 70
120

1: M4 5 mm deep
10 20

10

20

24

18

1: M4 5 mm deep

www.ifm.com

36 f8 58

50 h7 58

119

120

Evaluation systems

Selection chart
Universal speed monitors Speed monitor with integrated sensor Multifunctional displays for digital signals / frequency input Universal counters Multifunctional displays for analogue standard signals Accessories Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
123 123 123 123 124 124 124 124

www.ifm.com

121

Evaluation systems

Easy adjustment and parameter setting. Clear LCD display with simple pushbutton setup. Primary voltage 24V dc or 110 / 230V ac. Switching relays and transistor outputs. Analogue also available. Standstill, overspeed, direction, slip and frequency conversion.

Evaluation systems Although PLC applications in industrial automation are becoming more and more versatile there are still numerous processes in practice which require decentralised monitoring. For this ifm electronic offers a number of pulse evaluation systems in the product group ecomat 200. The application area ranges from simple standstill monitoring or blockage protection of a conveyor belt, maximum speed monitoring in wind power stations, slip monitoring of couplings through to direction monitoring, e.g. twin pumps with non-return valves. Different units for rail mounting and compact designs in M18 and M30 metal housings are available. They include microprocessor-controlled units for pane mounting to display analogue signals, RPM, speeds, processing times, quantities and electronic preset counters for the detection of quantities or linear measurement as well as electronic timer relays. All units are distinguished by a high reliability and easy handling. Independent of the PLC they indicate operating states or signal faults. This helps to reduce downtimes and production loss. ifm electronic offers the following evaluation systems: Speed monitor Standstill monitor Slip- / synchronisation monitor Direction monitor Frequency-to-current converter Threshold relay Displays with frequency and analogue input Counters Switching amplifiers
Machine cycles must also be monitored in conveying. Pulse evaluation systems are used for decentralised monitoring of drives.

www.ifm.com

122

Evaluation systems

Universal speed monitors


Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.

Type FR-1 dual-chamber terminals 2 x 2.5 mm (2 x AWG 14) plastics


110...240 AC/DC / 27 DC 1 PNP / NPN / Namur 1...60000 0.1...1000 1 2 2 1 DD2003

Speed monitor with integrated sensor


Type Sensing range [mm] 10 f 10 f Electrical design Ub [V] AC/DC DC PNP 20...250 AC/DC 10...36 DC Setting range [puls. / min.] 5...300 3...300 Start-up delay [s] 12 15 Terminal connection no. 1 2 Drawing no. 2 2 Order no.

DI0001* DI5001

10 f

DC PNP

10...36 DC

3...300

15

DI5009

12 nf

DC PNP

10...36 DC

3...6000

0...15

DI6001

f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 2 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Multifunctional displays for digital signals / frequency input
Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.

Type FX 360 10 screw terminals...1.5 mm (DC and inputs) plastics AC/DC


115/230 2 PNP / NPN 2 5 DX2003

Universal counters
Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.

Plug-in screw terminals plastics


90...260 AC 1 PNP / NPN 2 6 E89005

www.ifm.com

123

Evaluation systems

Multifunctional displays for analogue standard signals


Type Ub [V] Inputs Input function Setting range [puls. / min.] Setting range [Hz] Outputs analog Outputs relays Outputs transist. Drawing no. Order no.

terminals up to 2.5 mm plastics


1 4...20 mA 1 2 2 7 E89150

Accessories
Type Description Order no.

Angle bracket for type M18 Housing materials: stainless steel

E10736

Angle bracket for type M30 Housing materials: stainless steel

E10737

Wiring diagrams
1 2 3 4
1 L+

BN

L1 L+ N L

BN BK BU

L+

1 4

L+

2 4

BU

2: pulse output (the pulse sequence corresponds to the damping frequency), 4: switching output (adjustable)

Scale drawings - CAD download: www.ifm.com 1


45
1 2 3 9 4 10 5 11 6 12

3
120

92 82 pot. M12 x1 66 59 M 30 x1,5 LED 36 5 77 68 56 40 M12 x1 10 M18 x1 1 2 4 24

7A1 8A2

13 19

14 20

15 21

16 22

17 23

18 24

35,5

78

1: mounting on DIN rail 2


18 pot. 81 67 61 58

M30 x1,5

1: 3 LED, 2: setting pushbutton

2 LED

36

www.ifm.com

124

Evaluation systems

Scale drawings - CAD download: www.ifm.com 5


96

6
48 105 86,5 3

48

129

7
75 50 4

45

39

control panel cutout: 68 x 33 mm (according to DIN)

www.ifm.com

33

125

126

Level sensors

Selection chart
Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG, section 19 Variable level sensors for water-based media (dielectric constant > 20) Sensors for hydrostatic level monitoring Sensors for hydrostatic level monitoring in hygienic and wet areas Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG, section 19 Accessories for level sensors LK, LR, LT, LL, LI Accessories for level sensors PA, PG, PI, PN, PS, PY Scale drawings - CAD download: www.ifm.com Wiring diagrams

Page
129 129 129 - 130 130 131 131 132 133 133

www.ifm.com

127

Level sensors

Guided wave radar, capacitive and hydrostatic level sensors. No movings parts means high reliability and long life. Outputs for continuous or discrete level measurement. Integrated LED display for local indication of the current level. Units suitable for common industrial and process fluids.

Level sensors In industrial applications where fluids or bulk material are used, storage tanks or silos are used for processing or storing of media. Sensors are used to detect the levels. Even critical process conditions such as emptying a hydraulic tank or the unintentional overspill of a tank are monitored by level sensors. Advantages of electronic sensors Deposits and wear and tear often lead to failures in particular if mechanical switches are in contact with the medium. The electronic ifm sensors however can do without any mechanical components. This makes the sensors especially robust and reliable. Another advantage of electronic sensors is the local indication of the level or the easy setting of the switching threshold simply by pressing a button. Measurement technique For continuous level measurement the level is detected continuously, converted into an electrical signal and indicated. Depending on the type the units have freely programmable switching outputs or an analogue output for further processing. Continuous level sensors from ifm electronic use three different physical measuring principles: For capacitive measurement the probe and the tank form an electrical capacitor. The capacity changes with the level and is converted into a level measurement by a microprocessor. For hydrostatic level measurement a measuring cell detects the hydrostatic pressure of the material. Here the pressure change is a measure for the level. The efector gwr level sensor operates on the principle of guided wave radar. Electromagnetic pulses are transmitted by the sensor head and guided along the probe. If the microwave pulse hits the medium to be detected, it is reflected and the time of flight is evaluated by the sensor.
For special applications: Capacitive probe for monitoring oils and coolants. Measurement in the medium: Probe sensors will directly immersed in the medium to be monitored.

www.ifm.com

128

Level sensors

Sensors for oils and coolants, LK12xx: approval to the German overspill standard WHG, section 19
Type Probe length [mm] Active zone [mm] Inactive zone [mm] Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.

M12 connector (according to EN 61076-2-101) Output function 1 x analogue 4...20 mA / 0...10 V (OUT2); 1 x normally open / closed programmable (OUT-OP) DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 1 1 1 1 1 1 LK3122 LK3123 LK3124

M12 connector (according to EN 61076-2-101) Output function 2 x normally open / closed programmable DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 2 2 2 1 1 1 LK1022 LK1023 LK1024

M12 connector (according to EN 61076-2-101) Output function 3 x normally open / closed programmable (OUT1...OUT3); 1 x normally open / closed programmabl (OUT-OP) DC PNP
264 472 728 195 390 585 53 / 15 53 / 30 102 / 40 18...30 18...30 18...30 200 200 200 3 3 3 1 1 1 LK8122 LK8123 LK8124

Variable level sensors for water-based media (dielectric constant > 20)
Type Probe length [mm] Active zone [mm] Inactive zone [mm] Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.

M12 connector (according to EN 61076-2-101) Output function normally open / closed programmable; 4...20 mA or 0...10 V DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 4 2 LR3000

M12 connector (according to EN 61076-2-101) Output function 2 x normally open / closed programmable DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 2 2 LR7000

M12 connector (according to EN 61076-2-101) Output function 4 x normally open / closed programmable DC PNP
150...1600 L - 50 40/10 18...30 0...80 200 5 3 LR8000

Sensors for hydrostatic level monitoring


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
G I Display unit -0.25...0.25 10 30 18...32 9 4 PY2068

M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G I Display unit -0.5...0.5 10 30 20...30 10 5 PN2069

www.ifm.com

129

Level sensors

Type

Process connection

Display LED

Measuring range [bar]

Poverload max. [bar]

Pbursting min. [bar]

Ub DC [V]

Wiring diagram no.

Drawing no.

Order no.

Cable 3 m Output function 4...20 mA analogue DC


0...0.25 2 2.4 10...30 6 6 PS3208

Cable 10 m Output function 4...20 mA analogue DC


0...0.6 4 4.8 10...30 6 6 PS3407

Cable 12 m Output function 4...20 mA analogue DC


0...1 5 6 10...30 6 6 PS3417

M12 connector Output function 4...20 mA analogue DC


G I 0...0.25 10 30 9.6...32 7 7 PA3028

Sensors for hydrostatic level monitoring in hygienic and wet areas


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
Aseptoflex Aseptoflex Aseptoflex Display unit Display unit Display unit -1...1 -0.0124...0.25 -0.05...1 10 10 10 30 30 30 18...32 18...32 18...32 9 9 9 8 8 8 PI2099 PI2098 PI2097

M12 connector Output function 4...20 (20...4) mA analogue (scaleable 1:4) DC


Aseptoflex Aseptoflex Display unit Display unit -1...1 -0.05...1 10 10 30 30 20...32 20...32 11 11 8 8 PI1099 PI1097

M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit -0.005...0.1 -0.0124...0.25 -1...1 -0.05...1 -0.124...2.5 4 10 10 10 20 30 30 30 30 50 18...32 18...32 18...32 18...32 18...32 10 10 10 10 10 9 9 9 9 9 PI2789 PI2798 PI2799 PI2797 PI2796

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit -0.005...0.1 -0.0124...0.25 -1...1 -0.05...1 -0.124...2.5 4 10 10 10 20 30 30 30 30 50 18...32 18...32 18...32 18...32 18...32 9 9 9 9 9 10 10 10 10 10 PG2789 PG2798 PG2799 PG2797 PG2796

www.ifm.com

130

Level sensors

Sensors for oils and coolants, LI20xx: approval to the German overspill standard WHG, section 19
Type Probe length [mm] Output Ub [V] Medium temperature [C] Iload [mA] Wiring diagram no. Drawing no. Order no.

M12 connector Output function


132 273 481 737

DC PNP
10...36 10...36 10...36 10...36 200 200 200 200 8 8 8 8 11 11 11 11 LI5141 LI5142 LI5143 LI5144

normally open / closed programmable normally open / closed programmable normally open / closed programmable normally open / closed programmable

Accessories for level sensors LK, LR, LT, LL, LI


Type Description Order no.

Flange plate 73-90 / G for level sensors LR according to DIN 24557 Housing materials: flange: stainless steel / sealing: NBR

E43201

Flange plate 65-80 / G for level sensors LR Housing materials: flange: stainless steel

E43202

Probe Probe length: 240 mm for level sensors LR Housing materials: stainless steel

E43203

Probe Probe length: 450 mm for level sensors LR Housing materials: stainless steel

E43204

Probe Probe length: 700 mm for level sensors LR Housing materials: stainless steel

E43205

Probe Probe length: 1000 mm for level sensors LR Housing materials: stainless steel

E43207

Probe Probe length: 1200 mm for level sensors LR Housing materials: stainless steel

E43208

Probe Probe length: 1400 mm for level sensors LR Housing materials: stainless steel

E43209

Protective cover for LK / LL / LR / LT sensors Housing materials: PP

E43910

www.ifm.com

131

Level sensors

Accessories for level sensors PA, PG, PI, PN, PS, PY


Type Description Order no.

Protective cover for fluid sensors with connector M12 Housing materials: polyurethane

E30006

Protective cover for fluid sensors stainless steel with transparent Teflon window Housing materials: stainless steel 316Ti / 1.4571 / PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM

E30104

Adapter G - G Housing materials: stainless steel / FPM

E30007

Cable clamp fastener for submersible pressure transmitter PS3 Housing materials: steel / plastics

E30399

Filter element for submersible pressure transmitter PS3 for fixing on the capillary tube

E30400

Splitter box with ventilation and terminal block for submersible pressure transmitter PS3 Housing materials: plastics

E30401

Additional weight for submersible pressure transmitter PS3 Housing materials: stainless steel 316Ti / 1.4571

E30402

Welding adapter 50 mm with Aseptoflex thread Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant

E30052

Aseptoflex adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404

E33001

Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E30122

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33701

www.ifm.com

132

Level sensors

Wiring diagrams
1
1 BN 2 WH 4 BK

3
1 2 L+ 3 4 5 L 6 7 L+ Out 2 L Out 1 Out 3 Out-OP / Out 4 n.c.

5
1

7
2
4 5 6

L+
Out 2 Out 1 Out 3 Out 4 n.c.

L+

2: Out 2 3 BU 4: Out-OP

7
3

2
1
L+

4
1 2 4

4 2
2: Out 2 4: Out 1 2: OUT2 4: OUT1

L+

BN WH GY

L+ L

1 4 3

L+

11
1
1 L+

1 2 4
3

L+

1 4
2

L+

2
1 2 4 L 3 L+ L P L

10
1
2

1: Normal operation, 2: Programming operation (P = communication via EPS / FDT interface)


L+

1
2

L+

4
2: Out 2 4: Out 1

4
L
2: Out 2 4: Out 1 3

L+

L+

2
4
2: Out 2 4: Out 1 2: Out 2 4: Out 1

4 2
L

Scale drawings - CAD download: www.ifm.com 1


2 3

50

64

I1

16

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming buttons, 4: Housing connection (flat-pin connector 6.3 mm following DIN 46244)

www.ifm.com

I2

M12 x1

57

30,5

133

Level sensors

Scale drawings - CAD download: www.ifm.com 2


2 50 3 63

5
2 34
30

3 47

57

87

1 91,5

M12 x1 30 G 1/4
100

76

M12 x1

32

1,3

21,5 27

I1

G3 4

I2

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 6

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming buttons 3
2 50 3 63

57 76

M12 x1

30

7
30 M12 x1

87

32

I1

1,3

30
I2

G1 4 21,5 27

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming buttons 4
2 34 3 48

8
2 3 47

48 34

14

G3 4

75

27

14 119 M12 x1

1 91,5

M12 x1

57,3

1,3

14

36 14,5

21,5 27

30

G 1/4 36 4 5

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: Aseptoflex sealing edge, 5: Aseptoflex thread

www.ifm.com

134

85

57,3

Level sensors

Scale drawings - CAD download: www.ifm.com 9


2 50 3 64 1

10
100 57

105,8

M12 x1

16,8

52,8

34

G1

24

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button

G1

1: Analogue display, 2: 4-digit alphanumeric display, 3: Programming button 11


M12 x1 53 21,3 16 L

16,6

16,8

60,5

153

M12 x1

A
LED
1

1: Programming buttons

www.ifm.com

135

136

Flow sensors

Selection chart
Magnetic-inductive flow sensors with integrated temperature measurement (sealing material EPDM) Magnetic-inductive flow sensors (sealing material FKM) Compact housings for adapters for flow monitoring Compact designs for adapter with flow and temperature monitoring Compact housings for adapters for hygienic and wet areas Flow sensors for connection to control monitors, industrial applications Flow sensors for connection to control monitors, industrial applications, titanium housing Control monitors for industrial applications Flow sensors for connection to control monitors with ATEX approval Control monitors with ATEX approval Air flow monitors Compressed air meters Compressed air meter for special gases Inline sensor for small dosing quantities of water and aqueous solutions Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils) Accessories for flow sensors and control monitors Flange adapters for flow sensors Accessories for volumetric flow sensors Grounding clamps for magnetic-inductive volumetric flow sensors Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
139 139 139 140 140 140 140 141 141 142 142 142 143 143 143 143 - 144 144 - 145 145 145 145 - 146 146 - 150

www.ifm.com

137

Flow sensors

For liquids and gases. Special versions for food applications and hazardous areas. Optional fittings for variable process connection. Flow monitoring also for aggressive media.

Flow sensors In almost all fields of process and plant engineering liquids or gases are used for coolant and lubricant supply of machines and units, ventilation of installations and buildings and the processing of products. In case of no flow of these media considerable damage and downtime may result. Thus it is very important to monitor that these media are at the right place at the right time and in sufficient quantities. In modern installations electronic flow monitors are used for this purpose. They work without wear and tear and without mechanical components. This guarantees reliable monitoring even in case of difficult media over a long period. Operating principle Electronic flow sensors from ifm electronic operate with different measurement techniques. They meet all requirements from a simple monitoring function to the exact detection of flow quantities. Harmonised operating menus ensure that operators who use different flow sensors can quickly and precisely carry out settings on the sensors. Some flow sensors feature an integrated temperature monitor which makes an additional measuring point unnecessary. This enables to control processes in the optimum operating status especially with regard to energy savings. Analogue, binary and pulse outputs offer various possibilities to process the measured data. Due to the flexible programming by means of pushbuttons the flow sensors can be adapted to different conditions. The sensors are mounted via adapters.
Optimised consumption of compressed air. Monitoring very small flow rates: Flow monitor with flow adapter.

www.ifm.com

138

Flow sensors

Magnetic-inductive flow sensors with integrated temperature measurement (sealing material EPDM)
Type Process connection Measuring range [l/min] Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.

[V]

M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmG 0.25...25.00 -10...70 16 < 0.150 19...30 1 1 SM6100

0.5...50.0

-10...70

16

< 0.150

19...30

SM7100

G1

0.7...100.0

-10...70

16

< 0.150

19...30

SM8100

Magnetic-inductive flow sensors (sealing material FKM)


Type Process connection Measuring range [l/min] Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.

[V]

M12 connector Output function 4...20 mA analogue DC


G 0...25 -10...70 16 < 0.150 19...30 2 4 SM6050

Compact housings for adapters for flow monitoring


Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Pressure rating [bar] Response time [s] Ub [V] Drawing no. Order no.

M12 connector Wiring diagram no. 3


3...300 / 200...3000 3...100 / 200...800 -25...80 30 1...10 19...36 5 SI5000

1/2 UNF-Connector Wiring diagram no. 4


3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...10 85...265 6 SI5006*

M12 connector Wiring diagram no. 2


3...300 / 3...100 -25...80 / 300 1...10 19...36 7 SI5004

M12 connector Wiring diagram no. 5


3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...2 / 1...10 19...36 7 SI5010

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit.

www.ifm.com

139

Flow sensors

Compact designs for adapter with flow and temperature monitoring


Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Pressure rating [bar] Response time [s] Ub [V] Drawing no. Order no.

M12 connector Wiring diagram no. 6


3...300 / 200...3000 3...100 / 200...800 -25...80 300 1...10 19...36 7 SI5007

Compact housings for adapters for hygienic and wet areas


Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Pressure rating [bar] Response time [s] Ub [V] Drawing no. Order no.

M12 connector Wiring diagram no. 3


3...300 / 200...3000 3...100 / 200...800 -25...95 30 1...10 19...36 8 SI6600

3...300 / 200...3000

3...100 / 200...800

-25...95

30

1...10

19...36

SI6700

3...300 / 200...3000

3...100 / 200...800

-25...95

30

1...10

19...36

10

SI6800

Flow sensors for connection to control monitors, industrial applications


Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Max. T0 gradient [K/min] Pressure rating [bar] Drawing no. Order no.

M12 connector Wiring diagram no. 7


3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 30 30 11 SF6200

3...300 / 200...3000

3...60 / 200...800

-25...80

1...10

300

300

12

SF5200

Cable 6 m Wiring diagram no. 8


3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 300 300 13 SF5350

Flow sensors for connection to control monitors, industrial applications, titanium housing
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Max. T0 gradient [K/min] Pressure rating [bar] Drawing no. Order no.

M12 connector Wiring diagram no. 7


3...300 / 200...3000 3...60 / 200...800 -25...80 1...10 300 300 12 SF5700

Cable 6 m Wiring diagram no. 8


3...300 / 200...3000 3...60 / 200...800 0...120 / 0...100 1...10 300 300 13 SF5800

www.ifm.com

140

Flow sensors

Control monitors for industrial applications


Type Ub / Tolerance [V] / [%] Current consumpt. [mA] Power consumpt. [VA] Power-on delay time [s] Output when flow is present Output when temp. is exceeded Output in case of wire break Drawing no. Order no.

Combicon connector Wiring diagram no. 13


/ -5 /+10 4 10...80 relay energised relay energised relay de-energised 14 SN0150*

Combicon connector Wiring diagram no. 14


24 DC / +10 / 20 90 10...80 relay energised relay energised relay de-energised 14 SR0150*

M12 connector Wiring diagram no. 3


19...36 DC 70 10 no / nc programmable 15 SR5900

1/2 UNF-Connector Wiring diagram no. 4


85...265 AC / -5 / +10 < 3.5 10 no / nc programmable 16 SR5906*

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, Note: miniature fuse to IEC60127-2 sheet 1,. Recommendation: check the unit for reliable function after a short circuit. Flow sensors for connection to control monitors with ATEX approval
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Max. T0 gradient [K/min] Pressure rating [bar] Drawing no. Order no.

Cable 6 m Wiring diagram no. 9


3...300 / 200...2000 3...300 / 200...2000 3...60 / 200...800 3...60 / 200...800 -20...60 -20...70 1...10 1...10 15 15 300 30 17 18 SF211A SF221A

3...300 / 200...2000

3...60 / 200...800

-20...70

1...10

15

30

19

SF321A

M12 connector Wiring diagram no. 10


3...300 / 200...2000 3...60 / 200...800 -20...70 1...10 15 30 20 SF320A

www.ifm.com

141

Flow sensors

Control monitors with ATEX approval


Type Ub / Tolerance [V] / [%] Current consumpt. [mA] Power consumpt. [VA] Power-on delay time [s] Output when flow is present Output when temp. is exceeded Output in case of wire break Drawing no. Order no.

15 terminals...2.5 mm
230 AC / 10 110 AC / 10 24 DC / 10 125 5 5 30 30 30 relay energised relay energised relay energised relay de-energised relay de-energised relay de-energised 21 21 21 SN2301* SN2302* SR2301*

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, Wire break monitoring. Recommendation: check the unit for reliable function after a short circuit. Air flow monitors
Type Setting range liquids / gases [cm/s] Greatest sensitivity [cm/s] Medium temperature [C] Response time [s] Ub / tolerance [V] / [%] Drawing no. Order no.

Cable 2 m Wiring diagram no. 11


100...1000 100...400 -10...50 3...60 80...250 AC/DC 22 SL0101*

Cable 2 m Wiring diagram no. 12


100...1000 100...400 -10...50 3...60 24 DC 25 % 22 SL5101

* Note for AC and AC/DC units Miniature fuse to IEC60127-2 sheet 1, 5 A (fast acting). Recommendation: check the unit for reliable function after a short circuit. Compressed air meters
Type Setting range Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.

[Nm3/h]

[V]

M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA scaleable) DC PNP
0.14...15.00 0...60 16 < 0.1 19...30 15 23 SD5000

0.7...75.0

0...60

16

< 0.1

19...30

15

24

SD6000

2.0...225.0

0...60

16

< 0.1

19...30

15

25

SD8000

3.5...410.0

0...60

16

< 0.1

19...30

15

26

SD9000

6...700

0...60

16

< 0.1

19...30

15

27

SD2000

www.ifm.com

142

Flow sensors

Compressed air meter for special gases


Type Setting range Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.

[Nm3/h]

[V]

M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA scaleable) DC PNP
Ar: 0.8...118.2 / CO2: 0.5...71.7 / N2: 0.5...73.0 Nm/h 0...60 16 < 0.1 19...30 15 24 SD6100

Inline sensor for small dosing quantities of water and aqueous solutions
Type Process connection Measuring range [ml/min] Display range [ml/min] Pressure rating [bar] Medium temp. [C] Drawing no. Order no.

M12 connector Wiring diagram no. 15


G1/8 1...200 0...240 10 0...60 28 SQ0500

Ultrasonic flow rate sensors for liquids (water, glycol solutions, oils)
Type Process connection Measuring range [l/min] Medium temperature [C] Pressure rating [bar] Response time [s] Ub Wiring diagram no. Drawing no. Order no.

[V]

M12 connector Output function OUT1: normally open / closed programmable or pulse OUT2: normally open / closed programmable or analogue (4...20 mA / 0...10 V, scaleable) DC PNP/NPN
G 0.1...50.0 -10...80 16 < 0.250 19...30 1 29 SU7000

G1

0.2...100.0

-10...80

16

< 0.250

19...30

30

SU8000

G1

0.4...200.0

-10...80

16

< 0.250

19...30

31

SU9000

Accessories for flow sensors and control monitors


Type Description Order no.

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: titanium

E40114

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium

E40115

Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium

E40128

www.ifm.com

143

Flow sensors

Type

Description

Order no.

Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404

E40101

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404

E40099

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: stainless steel 316L / 1.4404

E40096

Welding adapter M18 x 1.5 - 23 mm Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: PE-100

E40138

Welding adapter M18 x 1.5 - 24 mm Insertion depth of the probe of SID, SFD, TN: 15 mm Housing materials: stainless steel 316L / 1.4404

E40124

Flow adapter (for low flow rates) M12 x 1 - G 1/8 for flow sensors and compact flow monitors with adapter Housing materials: stainless steel 316L / 1.4404

E40129

Flow adapter (for low flow rates) G - G 1/8 for flow sensors and compact flow monitors Housing materials: PVDF

E40057

Flange adapters for flow sensors


Type Description Order no.

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33702

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter Varivent type F DN25 (1), D = 50 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33721

www.ifm.com

144

Flow sensors

Type

Description

Order no.

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33722

Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E30122

Accessories for volumetric flow sensors


Type Description Order no.

Adapter G - R for flow monitor type SM6 flat seal Housing materials: stainless steel 316Ti / 1.4571 Pack quantity: 2

E40199

Adapter G - G for flow monitor type SM6 flat seal Housing materials: high-grade stainless steel

E40189

Grounding clamps for magnetic-inductive volumetric flow sensors


Type Description Order no.

Grounding clamp G for flow monitor type SM6 Housing materials: stainless steel

E40196

Wiring diagrams
1
1 2 4 3 BN WH BK BU L+ OUT2/InD OUT1 L

4
1 L1

7
2 WH
3 BU

10
1 BN 4 BK 5 GY 2 WH 3 BU

1 2 3 VS2000 Exi 7 8 9

2
3

n.c.
Out

1 BN

4 5

4 BK 5 GY

2
1 4 2 3
L+ n.c.

5
1 4 3 L 2 L P L+

8
WH
BU
BN
BK

11
BN
BK

L1 L+

WH
BU

GY

N L

n.c. = not connected 3

P = programming wire (for remote adjustment) 6

9
BN BK GY 1 2 3 VS2000 Exi 7 8 9

12
BN
BK

L+

1 4 3

L+

4
L

L+

WH BU

WH
BU

2
3

S2 S1

www.ifm.com

145

Flow sensors

Wiring diagrams
13
AC L N
1 2 4 5 6 7 17 18 19 20 21 22 23 24

14
L+ DC L WH BU BN BK GY 4 5 2 3 1 4 5 2
1 2 4 5 6 7 8 9 10 17 18 19 20 21 22 23 24

WH BU BN BK GY 4 5

2 3 1 4 5

8 9 10

11 12

11 12

1: Flow monitoring, 2: Wire break monitoring, 3: Temperature monitoring, 4: Power-on delay time, 5: Selection liquid / gas

1: Flow monitoring, 2: Wire break monitoring, 3: Temperature monitoring, 4: Power-on delay time, 5: Selection liquid / gas 15

1 2 4

L+

1 2 4

L+

4: Out 1 2: Out 2

4: Out 1 2: Out 2

Scale drawings - CAD download: www.ifm.com 1


110 73 54

4
110 73 54

G1 2

G1 2

G1 2

16

16

M12 x1

M12 x1

M12 x1

G1 2

M12 x1

2
110 73 54

5
1 50 2 63

G3 4

G 34

M12 x1

M12 x1
22

14

3
110 73 54

7,7

1: LED display, 2: setting pushbutton


G1 G1

19

M12 x1

M12 x1

www.ifm.com

146

45

60 65

113

19

M12 x1

27

Flow sensors

Scale drawings - CAD download: www.ifm.com 6


1 50 2 63
50 63

20UNF 2A 27

14

113

1 2"

45

60 65

22

34

8,2
15

1: LED display, 2: setting pushbutton 7


1 50 2 63

7,7 10,8

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread 10

27

M12 x1

50

38

89

137

63

45

60 65

22

14

8,2
106 34

50

63

M12 x1

27

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread 11


25 20 M12x1 7,7 217 146 45 15

71

119

15

7,7 10,8

55

1: LED display, 2: setting pushbutton

34 20

7,7

12
82 72 14 M12 x1 44 8,2

1: LED display, 2: setting pushbutton, 3: G1/Aseptoflex Vario thread

10

154

19

22 1

1: internal thread M18 x 1.5

www.ifm.com

M12 x1

113

27

M12 x1

27

147

Flow sensors

Scale drawings - CAD download: www.ifm.com 13


86 72 14 44 8,2
G1 4

17
57 13

27
8,2 G1 4

12

17 19 22 1

18 1: internal thread M18 x 1.5 14


25
1 2 3 4 5 6 7 8 9 10 11 12

57 13

27
7,7

12
103,5

LEDs

17

19
35,5

100

80 15 45 12
G1 2 7,7

LEDs

1 2

17 18 19 20 21 22 23 24

27

1: Potentiometer (switch point flow), 2: Potentiometer (switch point temperature) 15

20
75 15 45 12

M12 x1

1 50

2 64

83

M12 x1

48 52

27

27

21
45
120

3 19,7
1 2 8

3 9

1: LED display, 2: setting pushbutton, 3: connection for voltage supply and output signals, 4: connection for flow sensor 16
1 50 2 64
13 19 14 20 15 21 16 17

18

1: mounting on DIN rail


20UNF 2A 27

48 52

22
140 133 2 LED pot.

83

3 19,7 4
113 2 LED 32

1: LED display, 2: setting pushbutton, 3: connection for voltage supply and output signals, 4: connection for flow sensor

1 2"

35,5

78

G1 2

7,7
23

www.ifm.com

148

Flow sensors

Scale drawings - CAD download: www.ifm.com 23


1
45

27
2
1 2

133

3
74,5

M12 x1

54

21,3 1 G /4

G /4 31

R2 51

275 475

60 182,3

20

1: 4-digit alphanumeric display, 2: Programming buttons 1: 4-digit alphanumeric display, 2: Programming buttons, 3: hole for M5 fixing screw 24
45

28
117 111 100 M12 x1

1
45

11 1 100 M12 x1

76,8

21,3 R 16,1

G1 8

48
210 300

56 65

125 4,5

25
114

1
45

111 100 M12 x1

1: 4-digit alphanumeric display, 2: Programming buttons, 3: flow conditioner 29


110 96 80,5

88,5

33,7

R1 27,3

375 475

1: 4-digit alphanumeric display, 2: Programming buttons 26


1 2

37

1: 4-digit alphanumeric display, 2: Programming buttons

10

G34 100

G3 4

M12 x1

11 1 100

45

11 1 100

45

11 1 100

42

M12 x1

120

R11 2

39

installation length with pipe adapter E40151 / E40154: 185 mm


275 475

1: 4-digit alphanumeric display, 2: Programming buttons

www.ifm.com

M12 x1

149

Flow sensors

Scale drawings - CAD download: www.ifm.com 30


130 96 80,5

31
130 96 80,5 26

G11 4

G11 4 100

G1 100

G1

48

installation length with pipe adapter E40152 / E40155: 205 mm, installation length with pipe adapter E40153 / E40156: 215 mm

www.ifm.com

150

M12 x1

M12 x1

Flow sensors

151

152

Pressure sensors

Selection chart
Sensors with switching outputs and analogue outputs and display Sensors with switching outputs and display PK sensors with mechanical setting and switching outputs PT sensors for mobile applications with analogue outputs PA / PPA sensors for industrial applications with analogue outputs / AS-i Sensors for hydrostatic level monitoring PI sensors for hygienic and wet areas, 2-wire with analogue output PI sensors for hygienic and wet areas with switching and analogue output Full-metal sensors for hygienic and wet areas with switching output and analogue output Electronic contact manometers for hygienic and wet areas with switching output and analogue output Sensors for pump monitoring PF sensors for hygienic and wet areas with switching and analogue output PL / PM sensors without display for hygienic and wet areas with analogue output Sensors for hygienic and wet areas with Profibus PA Interface Fixing components for pressure sensors Accessories and software Adapters and accessories for adapters Flange adapters Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
155 155 155 156 156 156 157 157 157 158 158 158 159 159 159 159 - 160 160 160 - 161 161 - 162 162 - 164

www.ifm.com

153

Pressure sensors

Transmitters or sensors with integrated control monitor. Units with special design for hygienic applications. Measuring principles with overload protection and a good long-term stability. Measuring range from -1600 bar. Variable process connection and sealing technology via adapter.

Pressure sensors ifm offers a wide range of electronic pressure and vacuum sensors to meet the requirements of various industrial applications. The ceramic-capacitive measuring cell, tried and tested a million times, is complemented by a stainless steel measuring cell with thick-film wire strain gauges (series PK, PV, PT) and a piezoresistive measuring technique (for pneumatic applications). All units have robust housings and do not require moving parts such as pistons or springs. The result: the sensors are extremely shock and vibration resistant and operate without any wear or maintenance. The tried and tested ceramic-capacitive measuring principle is corrosion-resistant and long-term stable. In the long run this guarantees continuous accuracy of the measured values. The sensors are resistant to dynamic pressure peaks and guarantee high overload resistance even in the case of extreme pressure peaks that occur for example with fast closing valves. Units with wire strain gauge in thick-film technology on a stainless steel measuring cell are distinguished by their very compact and robust design. They can be used in almost all industrial areas. The welded stainless steel measuring cell without any seals ensures a high degree of safety, in particular for applications with gas pressures of up to 400 bar as well as in air-conditioning and refrigerating technology where aggressive coolants (freons) are used.
The display: The 7-segment display shows the system pressure at a glance.

Separate display / programming unit PP2001.

www.ifm.com

154

Pressure sensors

Sensors with switching outputs and analogue outputs and display


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
G I Display unit -0.25...0.25 10 30 18...32 7 1 PY2068

M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G I G I G I G I G I G I G I G I Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit 0...400 0...250 0...100 -1...25 -1...10 -0.125...2.5 -0.05...1 -1...1 600 400 300 100 75 20 10 20 1000 850 650 350 150 50 30 50 20...30 20...30 20...30 20...30 20...30 20...30 20...30 20...30 8 8 8 8 8 8 8 8 2 3 3 3 3 3 3 3 PN2020 PN2021 PN2022 PN2023 PN2024 PN2026 PN2027 PN2009

G I

Display unit

-0.5...0.5

10

30

20...30

PN2069

G I

Display unit

-0.0125...0.25

10

30

20...30

PN2028

Sensors with switching outputs and display


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M8 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x normally closed (diagnostic function) DC PNP
G 1/8 I G 1/8 I Display unit Display unit -1...1 -1...10 20 20 30 30 18...32 18...32 1 1 4 4 PQ7809 PQ7834

PK sensors with mechanical setting and switching outputs


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function normally open / closed complementary DC PNP


G A / M5 I G A / M5 I G A / M5 I G A / M5 I G A / M5 I Operation Operation Operation Operation Operation 0...400 0...250 0...100 0...25 0...10 600 400 200 60 25 1600 1000 1000 500 300 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 2 2 2 2 2 5 5 5 5 5 PK6520 PK6521 PK6522 PK6523 PK6524

www.ifm.com

155

Pressure sensors

PT sensors for mobile applications with analogue outputs


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 4...20 mA analogue DC


G A G A G A G A G A 0...400 0...250 0...100 0...25 0...10 600 400 200 60 25 1600 1000 1000 600 300 8.5...32 8.5...32 8.5...32 8.5...32 8.5...32 3 3 3 3 3 6 6 6 6 6 PT3550 PT3551 PT3552 PT3553 PT3554

M12 connector Output function 0...10 V analogue DC


G A G A G A G A G A 0...400 0...250 0...100 0...25 0...10 600 400 200 60 25 1600 1000 1000 600 300 16...32 16...32 16...32 16...32 16...32 4 4 4 4 4 6 6 6 6 6 PT9550 PT9551 PT9552 PT9553 PT9554

PA / PPA sensors for industrial applications with analogue outputs / AS-i


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 4...20 mA analogue DC


G I G I G I G I G I G I G I G I G I G I 0...600 0...400 0...250 0...100 0...25 0...10 0...2.5 0...1 0...0.25 -1...0 800 600 400 300 150 75 20 10 10 10 1200 1000 850 650 350 150 50 30 30 30 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 9.6...32 3 3 3 3 3 3 3 3 3 3 7 7 8 8 8 8 8 8 8 8 PA3060 PA3020 PA3021 PA3022 PA3023 PA3024 PA3026 PA3027 PA3028 PA3029

Sensors for hydrostatic level monitoring


Type Measuring range [bar] Cable length / material Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

Output 4...20 mA analogue Wiring diagram no. 5


0...0.25 0...0.6 0...1 3m PUR cable 10 m PUR cable 12 m PUR cable 2 4 5 2.4 4.8 6 10...30 10...30 10...30 5 5 5 9 9 9 PS3208 PS3407 PS3417

www.ifm.com

156

Pressure sensors

PI sensors for hygienic and wet areas, 2-wire with analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 4...20 (20...4) mA analogue (scaleable 1:4) DC


Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex G1 A G1 A G1 A G1 A G1 A G1 A G1 A Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -1...1 -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 100 50 30 20 10 10 100 50 30 20 10 10 10 350 150 100 50 30 30 350 150 100 50 30 30 30 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 20...32 9 9 9 9 9 9 9 9 9 9 9 9 9 10 10 10 10 10 10 11 11 11 11 11 11 11 PI1093 PI1094 PI1095 PI1096 PI1097 PI1099 PI1693 PI1694 PI1695 PI1696 PI1697 PI1698 PI1699

PI sensors for hygienic and wet areas with switching and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (I / U, scaleable 1:4) DC PNP/NPN
Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Aseptoflex Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 100 50 30 20 10 10 10 350 150 100 50 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 7 7 7 7 7 7 7 10 10 10 10 10 10 10 PI2093 PI2094 PI2095 PI2096 PI2097 PI2098 PI2099

Full-metal sensors for hygienic and wet areas with switching output and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 -0.005...0.1 100 50 30 20 10 10 10 4 350 150 100 50 30 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 8 8 8 8 8 8 8 8 12 12 12 12 12 12 12 12 PI2793 PI2794 PI2795 PI2796 PI2797 PI2798 PI2799 PI2789

www.ifm.com

157

Pressure sensors

Electronic contact manometers for hygienic and wet areas with switching output and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP/NPN
Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario Aseptoflex Vario G G G G G G G G Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit Display unit -1...25 -1...10 -1...4 -0.124...2.5 -0.05...1 -0.0124...0.25 -1...1 -0.005...0.1 0...250 0...100 -1...25 -1...10 -0.125...2.5 -0.05...1 -0.0125...0.25 -0.005...0.1 100 50 30 20 10 10 10 4 600 300 100 50 20 10 10 4 350 150 100 50 30 30 30 30 1000 700 300 150 50 30 30 30 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 18...32 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 13 13 13 13 13 13 13 13 14 14 14 14 14 14 14 14 PG2793 PG2794 PG2795 PG2796 PG2797 PG2798 PG2799 PG2789 PG2451 PG2452 PG2453 PG2454 PG2456 PG2457 PG2458 PG2489

Sensors for pump monitoring


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 1 x normally open / normally closed programmable + 1 x normally open / normally closed programmable or 1 x analogue (4...20 / 20...4 mA, scalable) DC PNP
G1 A G1 A Display unit Display unit -1...25 -1...10 100 50 350 150 18...32 18...32 10 10 11 11 PIM693 PIM694

PF sensors for hygienic and wet areas with switching and analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V; scaleable 1:4) DC PNP/NPN
G1 A Switching status -1...100 200 650 20...30 8 15 PF2652

G1 A G1 A G1 A G1 A G1 A

Switching status Switching status Switching status Switching status Switching status

-1...25 -0.5...10 -0.13...2.5 -0.05...1 -0.013...0.25

100 50 20 10 10

350 150 50 30 30

20...30 20...30 20...30 20...30 20...30

8 8 8 8 8

16 16 16 16 16

PF2653 PF2654 PF2656 PF2657 PF2658

www.ifm.com

158

Pressure sensors

PL / PM sensors without display for hygienic and wet areas with analogue output
Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Output function 4...20 mA analogue DC


Aseptoflex Aseptoflex Aseptoflex Aseptoflex -1...25 -0.5...10 -0.05...1 -0.0125...0.25 100 50 10 10 350 150 30 30 14...30 14...30 14...30 14...30 11 11 11 11 17 17 17 17 PM2053 PM2054 PM2057 PM2058

Sensors for hygienic and wet areas with Profibus PA Interface


Type Process connection Display LED Measuring range [bar] Poverload max. [bar] Pbursting min. [bar] Ub DC [V] Wiring diagram no. Drawing no. Order no.

M12 connector Profibus PA, electrically isolated Wiring diagram no. 6


Aseptoflex Aseptoflex Aseptoflex Aseptoflex -1...10 -1...4 -0.124...2.5 -0.05...1 50 30 20 10 150 100 50 30 9...32 9...32 9...32 9...32 6 6 6 6 18 18 18 18 PMP094 PMP095 PMP096 PMP097

Fixing components for pressure sensors


Type Description Order no.

Mounting clamp 34 mm Housing materials: PBT

E10017

Accessories and software


Type Description Order no.

Protective cover for fluid sensors with connector M12 Housing materials: polyurethane

E30006

Protective cover for fluid sensors stainless steel with transparent Teflon window Housing materials: stainless steel 316Ti / 1.4571 / PFA / EPDM / ventilation strip: Teflon film 0.32 mm / O-ring: EPDM

E30104

Programming/ display unit for EPS and IO-Link sensors Connector Housing materials: stainless steel 316L / 1.4404 / EPDM/X / PC copolymer / PBT / FPM

PP2001

Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent

E30094

IO-Link interface for parameter setting and analysis of units with DTM specification Supported communication protocols: IO-Link (4800 and 38400 bits/s) EPS protocol (19200 bits/s) contains ifm Container software (E30110)

E30396

Cable clamp fastener for submersible pressure transmitter PS3 Housing materials: steel / plastics

E30399

www.ifm.com

159

Pressure sensors

Type

Description

Order no.

Filter element for submersible pressure transmitter PS3 for fixing on the capillary tube

E30400

Splitter box with ventilation and terminal block for submersible pressure transmitter PS3 Housing materials: plastics

E30401

Additional weight for submersible pressure transmitter PS3 Housing materials: stainless steel 316Ti / 1.4571

E30402

Adapters and accessories for adapters


Type Description Order no.

Adapter G - G Housing materials: stainless steel / FPM

E30007

Adapter G 1 - G Housing materials: stainless steel 316L / 1.4404 / sealing: FPM

E30116

Flange adapters
Type Description Order no.

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33702

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter Varivent type F DN25 (1), D = 50 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33721

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33722

www.ifm.com

160

Pressure sensors

Type

Description

Order no.

Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E30122

Adapter plug for Aseptoflex Vario adapter Housing materials: high-grade stainless steel

E30128

Aseptoflex adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404

E33001

Aseptoflex adapter Clamp 2 ISO 2852 for units with Aseptoflex adapter Housing materials: stainless steel 316L / 1.4404

E33002

Welding adapter 50 mm with Aseptoflex thread Housing materials: stainless steel 316L / 1.4404 / O-ring: FPM FDA compliant

E30052

Adapter plug for welding adapter with Aseptoflex thread Housing materials: high-grade stainless steel

E30064

Wiring diagrams
1
1
L+

4 2
2: Out 2 4: Out 1

L+

BN WH

L+ L

2
L

GY

2
1
L+

6
1 PA+ n.c. n.c. PA

2
4

1
2 3

L+

2 4

4: 2:

8
1
L+
2: Out 2 4: Out 1

1 2 4
3

L+

1 4
2

L+

1
2

L+

4 3
L L
2: Out 2 4: Out 1

4
3

L+

L+

2
4
2: Out 2 4: Out 1 2: Out 2 4: Out 1

4 2
L

www.ifm.com

161

Pressure sensors

Wiring diagrams
9
1
1 L+

11
2
1 2 4 L 3 L+ L P L 1 L+ 1 2 2 L 3 L L+

1: Normal operation, 2: Programming operation (P = communication via EPS / FDT interface) 10

1 2 4

L+

1 2 4

L+

4: Out 1 2: Out 2

4: Out 1 2: Out 2

Scale drawings - CAD download: www.ifm.com 1


2 34 3 48

3
2 34 3 47

1 91,5

M12 x1

1 91,5

M12 x1 30 G 1/4
35 42 20,7 11,3 32 4,2 32

57,3

1,3

1,3

14

21,5 27

21,5 30 G 1/4 27

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 2
2
34

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button 4

3
47,8

1 94,1

M12 x1

59,6

4,75

21,5 27 30 G 1/4

1: 4-digit alphanumeric display, 2: LEDs (display unit / switching status), 3: Programming button

16,5

1,3

20

30

1: main pressure connection G 1/8; tightening torque max. 8 Nm, thread length max: 7.5 mm, 2: for mounting screw M4; max. tightening torque 2.5 Nm, 3: LEDs (display unit / switching status), 4: 4digit alphanumeric display, 5: Programming button

www.ifm.com

162

14

57,3

Pressure sensors

Scale drawings - CAD download: www.ifm.com 5


27 M12 x1

10
2 3 47

48 34

61,6 71,6

7,5

1 12 119

1: tightening torque 25 Nm, 2: sealing FPM / DIN 3869-14 6

36 14,5

36 22 M12 x1

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: Aseptoflex sealing edge, 5: Aseptoflex thread
51,2 65,1

11
2 48 34 3 47

22 1

G/

14

12

1: sealing FPM / DIN 3869-14, tightening torque 25 Nm


1

7
30 M12 x1 27 119 85 41 1,3 16,5

77,5

25,4 G1

20

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button 12


2 3 50 64

30

G1 4 21,5 27

8
30 M12 x1

M12 x1
G1

75

1,3

30

G1 4 21,5 27

34

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button 9


100

www.ifm.com

27

16,8

14

52,8

105,8

M12 x1

85

27 2

M5 G 1/4

M12 x1

163

Pressure sensors

Scale drawings - CAD download: www.ifm.com 13


100 57

16
1 48,5 34 2 46,5

M12 x1

153

97,4

M12 x1 3 24
G1

16,8

60,5

27,5

25,4 G1

41

20

1: 7-segment LED display, 2: Programming button 17


48 34 M12 x1

1: Analogue display, 2: 4-digit alphanumeric display, 3: Programming button 14


100 57

M12 x1

169

15

107 121,5

36

75,5

1: Aseptoflex sealing edge, 2: Aseptoflex thread 18


58 50 M12 x1

22

G1 2

24

1: Analogue display, 2: 4-digit alphanumeric display, 3: Touch button (programming button) 15


1 34 2 46,5

92

M12 x1

58

36 1 2

M12 x1

27,5

25,4 G1

41

20

1: Aseptoflex sealing edge, 2: Aseptoflex thread

1: 7-segment LED display, 2: Programming button

www.ifm.com

164

14,5

108 122,8

63,1

Pressure sensors

165

166

Temperature sensors

Selection chart
Compact temperature sensors Compact temperature sensors with display Control monitors for temperature sensors Control monitors for temperature sensors Pt1000 probe sensors for standard applications Pt100 probe sensors for standard applications Cable sensors for standard applications Cable sensors with bolt-on sensor for standard applications Temperature transmitters for standard applications AS-i temperature transmitters for standard applications Probe sensors for hygienic and wet areas Cable sensors for hygienic and wet areas Temperature transmitters for hygienic and wet areas AS-i temperature transmitters for hygienic and wet areas Self-monitoring temperature transmitters for hygienic and wet areas Profibus-Temperaturtransmitter mit ATEX-Zulassung 1G, 1/2GD, 2GD Accessories for temperature sensors TN / TR Accessories and software Adapters Thermowells for temperature sensors Flange adapters Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
169 169 169 - 170 170 170 171 171 171 171 172 172 172 172 173 173 173 173 173 174 - 175 175 175 - 176 176 - 177 177 - 180

www.ifm.com

167

Temperature sensors

Increased process safety due to self-monitoring. Compact units with integrated sensors or modular systems. Robust construction for high resistance to shock and vibration. Direct contact with medium or thermowell mounting. Units with diverse redundant sensors for critical tasks.

Temperature sensors The controlling and monitoring of temperatures are amongst the most important measuring tasks in automation and process technology. In process technology for example the right temperature is decisive for the quality and efficiency of the process. In automation technology an exact temperature detection is very important for monitoring installations and as protection against dangerous states. In heating and air conditioning economic and easy operation is not possible without temperature measurement and control. Operating principle The temperature sensors of ifm electronic are based on a Pt100 or Pt1000 resistor. The measured temperature value corresponds to a change in resistance and is converted into an electrical analogue signal. The microprocessor and the display make process adjustment much easier. The user can set the values for the switch points, hysteresis and measuring range by means of programming buttons even without the system temperature being applied. This enables installation and setup of the system within a few minutes. Film technology is used for the electronic circuitry. A flexible, temperature-resistant and extremely resistant polyimide film is used as carrier of the SMD components. Together with a special potting method an extreme shock and vibration resistance is achieved. From sensor to system A complete temperature measurement system usually consists of several components. The temperature in a medium is detected by a sensor and is converted into an electrical measured signal. The mechanical design and the dimensions of the sensors must vary to enable use for different media and measuring points. ifm electronic offers a selection of robust probe sensors or types with connection cables. To indicate and process the measured value the sensor is connected to a separate control monitor. For further processing, freely programmable switching or analogue outputs are available. If a local temperature display is not required, temperature transmitters are frequently used. ifm electronic provides units with excellent response times (TA series) that either have standard output signals or an integrated AS-i interface. In hygienic applications the self-monitoring, calibration-free temperature transmitter TAD is an excellent choice.
Local display of the current temperature.

Imperative: Temperature detection in heating and air conditioning.

www.ifm.com

168

Temperature sensors

Compact temperature sensors


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector Output function normally open / closed complementary DC PNP


-25...140 G A 25 9.6...32 1/3 1 1 TK6130

-25...140

NPT

35

9.6...32

1/3

TK6330

M12 connector Output function


-25...140 G A

DC PNP
25 9.6...32 1/3 2 1 TK7130

-25...140

NPT

35

9.6...32

1/3

TK7330

M12 connector Output function 1 x normally open / 1 x normally closed DC PNP


-25...140 G A 255 9.6...32 1/3 2 3 TK7480

Compact temperature sensors with display


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) DC PNP/NPN
-40...150 M18 x 1.5 45 18...32 1/3 7 4 TN2531

M12 connector Output function 2 x normally open / closed programmable DC PNP/NPN


-40...150 M18 x 1.5 45 18...32 1/3 8 4 TN7531

Control monitors for temperature sensors


Type Measuring range [C] Process connection Display LED Ub [V] Current consump. [mA] Iload [mA] Wiring diagr. no. Drawing no. Order no.

M12 connector Output function 4 x normally open / closed programmable DC PNP


-40...150 G A Display unit 18...28 90 < 500 9 5 TR8430

www.ifm.com

169

Temperature sensors

Type

Measuring range [C]

Process connection

Display LED

Ub [V]

Current consump. [mA]

Iload [mA]

Wiring diagr. no.

Drawing no.

Order no.

M12 connector Output function 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable) DC PNP/NPN
-40...300 G A Display unit 20...30 55 250 10 5 TR2432

M12 connector Output function 2 x normally open / closed programmable DC PNP/NPN


-40...300 G A Display unit 18...32 50 250 11 6 TR7432

Control monitors for temperature sensors


Type Measuring range [C] Process connection Display LED Ub [V] Current consump. [mA] Iload [mA] Wiring diagr. no. Drawing no. Order no.

M12 connector Output function 4...20 mA analogue DC


0...100 20...32 12 7 TP3237

Pt1000 probe sensors for standard applications


Type Measuring range [C] Diameter [mm] Probe length [mm] Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel


-40...150 -40...150 6 6 160 360 1 x Pt 1000 1 x Pt 1000 1/3 1/3 3 3 8 8 TT1250 TT3250

-40...150 -40...150 -40...150 -40...125

10 10 10 8.2

160 260 560 44

1 x Pt 1000 1 x Pt 1000 1 x Pt 1000 1 x Pt 1000

1/3 1/3 1/3 1/3

3 3 3 3

9 9 9 10

TT1050 TT2050 TT5050 TM9550

-40...150

10

50

1 x Pt 1000

5 / 14

11

TM0061

www.ifm.com

170

Temperature sensors

Pt100 probe sensors for standard applications


Type Measuring range [C] Diameter [mm] Probe length [mm] Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel


-40...150 10 260 1 x Pt 100 1/3 3 9 TT2081

Cable sensors for standard applications


Type Measuring range [C] Diameter [mm] Cable material Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

Cable with connector 2 m high-grade stainless steel


-40...150 6 / L = 45 FPM (Viton) cable 1 x Pt 1000 3 / 10 3 12 TS2251

-40...150

10 / L = 45

FPM (Viton) cable

1 x Pt 1000

6 / 25

13

TS2051

-50...250

6 / L = 50

PTFE cable

1 x Pt 100

11 / 37

14

TS2256

-50...250

10 / L = 50

PTFE cable

1 x Pt 100

12 / 39

15

TS2056

Cable with connector 5 m high-grade stainless steel


-40...150 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS5051

Cable sensors with bolt-on sensor for standard applications


Type Measuring range [C] Diameter [mm] Cable material Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

Cable with connector 2 m stainless steel


-25...90 M6 / 12 x 51 PUR cable 1 x Pt 100 9 / 15 3 16 TS2229

Temperature transmitters for standard applications


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel DC


-50...150 0...140 G A G A 46.5 46.5 10...30 10...30 1/3 1/3 4 4 17 17 TA3131 TA3130

www.ifm.com

171

Temperature sensors

AS-i temperature transmitters for standard applications


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel DC


-10...150 G A 46.5 18...31.6 1/3 5 18 TAA131

Probe sensors for hygienic and wet areas


Type Measuring range [C] Diameter [mm] Probe length [mm] Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel


-40...150 -40...150 10 10 110 160 1 x Pt 1000 1 x Pt 1000 1/3 1/3 3 3 9 9 TT0061 TT1061

Cable sensors for hygienic and wet areas


Type Measuring range [C] Diameter [mm] Cable material Sensor element Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

Cable with connector 2 m high-grade stainless steel


-40...150 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS2051

Cable with connector 5 m high-grade stainless steel


-40...150 10 / L = 45 FPM (Viton) cable 1 x Pt 1000 6 / 25 3 13 TS5051

Cable with connector 2 m high-grade stainless steel


-50...250 10 / L = 50 PTFE cable 1 x Pt 100 12 / 39 3 15 TS2056

Temperature transmitters for hygienic and wet areas


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel DC


0...100 0...140 -10...150 -10...150 G A G A G A 6 mm 87.5 87.5 87.5 123 10...30 10...30 10...30 10...30 1/3 1/3 1/3 1.2 / 3.5 4 4 4 4 19 19 19 20 TA3437 TA3430 TA3431 TA3231

www.ifm.com

172

Temperature sensors

AS-i temperature transmitters for hygienic and wet areas


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector high-grade stainless steel DC


-10...150 G A 87.5 18...31.6 1/3 5 21 TAA431

Self-monitoring temperature transmitters for hygienic and wet areas


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector Output function normally open / normally closed / heartbeat programmable, 4...20 mA analogue DC PNP/NPN
-25...150 Aseptoflex Vario 87.5 15...32 3/6 13 22 TAD181

-25...150

Aseptoflex Vario

33

15...32

3/6

13

23

TAD981

Profibus-Temperaturtransmitter mit ATEX-Zulassung 1G, 1/2GD, 2GD


Type Measuring range [C] Process connection Probe length [mm] Ub [V] Dynamic response T05 / T09 [s] Wiring diagr. no. Drawing no. Order no.

M12 connector Wiring diagram no. 6


-25...150 Aseptoflex Vario 87.5 9...32 3/6 6 24 TAP18A

-25...150

Aseptoflex Vario

33

9...32

3/6

25

TAP98A

Accessories for temperature sensors TN / TR


Type Description Order no.

Mounting clamp 34 mm Housing materials: PBT

E10017

Protective cover for fluid sensors with connector M12 Housing materials: polyurethane

E30006

Accessories and software


Type Description Order no.

IO-Link interface for parameter setting and analysis of units with DTM specification Supported communication protocols: IO-Link (4800 and 38400 bits/s) EPS protocol (19200 bits/s) contains ifm Container software (E30110)

E30396

www.ifm.com

173

Temperature sensors

Adapters
Type Description Order no.

Thread cover 26 mm - G to cover the G thread for installation in hygienic areas for type TA Housing materials: stainless steel 316L / 1.4404

E30090

Mounting set for direct connection of temperature sensors TT to control monitors TR Housing materials: stainless steel

E30017

Mounting set G for direct connection of temperature sensors TM to control monitors TR Housing materials: stainless steel 316L / 1.4404 / stainless steel

E30089

Clamp fitting 6/8/10 mm - G for temperature sensors TS / TT Housing materials: stainless steel / FPM

E30018

Clamp adapter 10 mm - G no dead space Housing materials: stainless steel 316L / 1.4404 / FPM

E34410

Welding adapter M18 x 1.5 - 24 mm Insertion depth of the probe of SID, SFD, TN: 15 mm Housing materials: stainless steel 316L / 1.4404

E40124

Welding adapter G - 35 mm ball Housing materials: stainless steel 316L / 1.4404

E30055

Welding adapter G - 45 mm collar Housing materials: stainless steel 316L / 1.4404

E30056

Welding adapter 50 mm for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E30122

Progressive ring fitting for temperature sensors 10 mm - G Housing materials: stainless steel 316Ti / 1.4571

E30016

Progressive ring fitting for temperature sensors 6 mm - G Housing materials: stainless steel 316Ti / 1.4571

E30047

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: titanium

E40114

Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: titanium

E40128

Adapter M18 x 1.5 - M12 x 1 Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404

E40101

www.ifm.com

174

Temperature sensors

Type

Description

Order no.

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 13.5 mm Housing materials: stainless steel 316L / 1.4404

E40099

Adapter M18 x 1.5 - G Insertion depth of the probe of SID, SFD, TN: 21 mm Housing materials: stainless steel 316L / 1.4404

E40096

Adapter M18 x 1.5 - NPT Insertion depth of the probe of SID, SFD, TN: 23 mm Housing materials: stainless steel 316L / 1.4404

E40107

G adapter Clamp 1-1.5 DIN 32676 for units with G adaptation Housing materials: stainless steel 316L / 1.4404

E33401

G adapter Clamp 2 DIN 32676 for units with G adaptation Housing materials: stainless steel 316L / 1.4404

E33402

Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent

E30094

Thermowells for temperature sensors


Type Description Order no.

Welding thermowell 35 mm Probe length: 126.5 mm for type TA343x, TAA431, TAD191 Housing materials: stainless steel 316L / 1.4404

E30403

Thermowell for temperature sensors G Probe length: 53 mm for type TA34xx, TAA431, TAD191 Housing materials: stainless steel 316L / 1.4404

E30393

Thermowell for temperature sensors 10 mm - G Probe length: 82 mm Housing materials: stainless steel 316L / 1.4404

E35010

Thermowell for temperature sensors 6 mm - G Probe length: 82 mm Housing materials: stainless steel 316Ti / 1.4571

E37010

Flange adapters
Type Description Order no.

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33202

Aseptoflex Vario adapter Clamp 2 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33702

www.ifm.com

175

Temperature sensors

Type

Description

Order no.

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33201

Aseptoflex Vario adapter Clamp 1-1.5 ISO 2852 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33701

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Sealing by sealing ring Housing materials: stainless steel 316L / 1.4435

E33222

Aseptoflex Vario adapter Varivent type N DN40 (1.5), D = 68 for units with Aseptoflex Vario adapter Metal to metal seal Housing materials: stainless steel 316L / 1.4435

E33722

Wiring diagrams
1
1
L+

3
1 2 3

2
4

AS-i+

4: 2:

AS-i

2
1
L+

6
1 PA+ n.c. n.c. PA

4 2
2: Out 2 4: Out 1

L+

2 4

2
L

9
1
L+
Out 2 Out 1 Out 3 Out 4 n.c.

1 2 4
3

L+

1 4
2

L+

1 (n.c.)
2
3 (n.c.)

4 5
TR 8430

6
7 3

1 2 4 2: Out 2 4: Out 1 3

L+

1 2 4 2: Out 2 4: Out 1

L+

www.ifm.com

176

Temperature sensors

Wiring diagrams
10
1

12

B 1 B

2 3 4 1 1 BN 2 WH 4 BK TR 2432 3 BU

B 1 L+ B

2 3 4

B 2
1 2

1 2
TP

2 3 4

L+ L IO-Link L

3 4

L 2

1 2 3 4

4 3

3 4

1: Two-wire sensor, 2: Three-wire sensor, 3: Four-wire sensor, B: link 11

1: Two-wire sensor, 2: Four-wire sensor, 3: Operation as 2-wire temperature transmitter, 4: Operation as 3-wire unit, IO-Link communication possible, B: link 13

B 1 B

2 3 4 1 1 BN 2 WH TR 4 BK 3 BU

1
1 BN

2
1 BN

B 2
1 2

2 3 4

L+
2 WH

L+

2 WH 4 BK

L+

3 BU

3 4

1: 2-wire operation, 2: 3-wire operation

1: Two-wire sensor, 2: Three-wire sensor, 3: Four-wire sensor, B: link

Scale drawings - CAD download: www.ifm.com 1


27 M12 x1

2
27 M12 x1

87

14

8,2 8,2

www.ifm.com

35 48

G1 4

25

27

39

27 -18 NPT

96

105,5

96,5

177

Temperature sensors

Scale drawings - CAD download: www.ifm.com 3


27 M12 x1

6
2 34 3 48

327

93

M12 x1 G1 2 16,5 30 4
23,5 M12x1 LED 17 M12x1 2

27

255 267

G1 2

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: connection for temperature sensor 7

4
2 34 3

48

M12x1

14

128

94,5

45

1: connection for voltage supply and output signals, 2: connection for temperature sensor
22 4

8,2

8
21,5 6,2 L

5
2 34 3 48

18,5 M12x1

1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: internal thread M18 x 1.5

20 50

40 1

1: plug area
M12 x1 1 93

9
21,5

M12x1

18,5

60

16,5

40 1 30 4

G1 2

1: plug area 1: 4-digit alphanumeric display, 2: LEDs, 3: Programming button, 4: connection for temperature sensor 10
M12x1

8,2

1: internal thread M18 x 1.5

www.ifm.com

178

44

60

22

90

19

14

12

8 10

5,95

13,8

60

Temperature sensors

Scale drawings - CAD download: www.ifm.com 11


45 50
4,5 10

17
30 M12x1
13,7

36 M12x1

30

72 6 48 45

M12 x1

8,2

18 13
7 10
46 45

30 M12x1
14,9 53
LED

M12 x1

12

60 13,5

12

27

G1 4

13,5 27 6 G1 4

1: Aseptoflex thread, 2: Aseptoflex sealing edge

14
42,5

50

M12 x1

8,2

15
50 42

19
180,5

7 10

42,5

13,7

43,8

123 87,5

M12 x1

60

127,9

117,7

44

30 M12x1

16
51 14 35 12

LED

27

G1 2

20
171 14 30 M12x1 34 123 6
17 1,8 8,7

M12 x1

49,5

6,5

21
190,5 14,7 52,8 123 87,5

30 M12x1

8,2 10 18,3

47,5

LED

27

G1 2

www.ifm.com

18,3

12

8,2 10

47,5

179

Temperature sensors

Scale drawings - CAD download: www.ifm.com 22


210,5 195,7 140,5 87,5 8 10

24
210,5 195,7 140,5 87,5 8 10 50,4 M12x1 1 34 G1

50,4 M12x1

34

G1

23
156 141,2 86 33 8 10

1: Grounding screw 25
156 141,2 86 33 8 10 34 G1 1 34 G1

50,4 M12x1

1: Grounding screw

www.ifm.com

180

50,4 M12x1

Temperature sensors

181

182

Diagnostic systems

Selection chart
Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE Accessories VB / VE Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK Accessories VK Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE Accessories VSE Vibration sensors for connection to external diagnostic electronics VSE - type VSA Accessories VSA Scale drawings - CAD download: www.ifm.com

Page
185 185 185 186 186 186 186 - 187 187 187 - 188

www.ifm.com

183

Diagnostic systems

Online vibration diagnosis optimum price / performance ratio. Decentralised monitoring of plant and equipment integrated into the machine. Compact field units and modular control cabinet units. Digital and analogue alarm outputs. Standard data interface (OPC).

Diagnostic systems efector octavis is a vibration monitor which not only detects vibration data, but also carries out signal analysis and machine diagnosis directly on the machine. The machine condition is determined and is forwarded to the PLC or to SCADA software. It fulfils the main requirements for modern machine monitoring: compatibility, modularity and transferable configuration. Compatible and modular The compatibility with data structures such as the OPC interface makes it possible to integrate condition data into a higher-level system. With the requirement for modularity the user can define the extent of condition monitoring to be implemented this means the complete range of diagnosis is possible right from the first unit. Transferable configuration is attained with application-related parameter sets. A wizard function in the software guides the user through creating, managing and archiving the monitoring parameters. Trend memory All units of the octavis family type VE / VSE feature an internal trend memory which ensures detailed analysis and optimisation of the application even without external data recording. The storage intervals are freely selectable. This means that the storage length of the non volatile ring-memory is adjusted to the requirements. The suitable system for your application: Standard vibration characteristic values / permanent machine protection: VSE, VE, VK Internal trend memory / root cause analysis: VSE, VE Online diagnosis / early damage detection: VSE (VE partly) Network capability of the system: VSE (VE partly*) *Profibus DP gateway
Easy vibration monitoring: type VK provides a combination of switching output and transmitter function in conjunction with the tried and tested easy-turn concept.

Internal trend memory (type VE / VSE) of all monitored diagnosis factors can be evaluated via PC software.

www.ifm.com

184

Diagnostic systems

Compact vibration diagnostic units with g-monitor to ISO 10816 type VB/VE
Type Description Drawing no. Order no.

Vibration diagnostic unit Spectral analysis / FFT Envelope-curve FFT Peak V eff RMS Trend analysis Connection via M12 x 1 and M8 x 1 connectors housing: diecast zinc nickel-plated / keypad: polyester

VE1001

Vibration diagnostic unit Spectral analysis / FFT Envelope-curve FFT Peak V eff RMS Trend analysis Connection via M12 x 1 and M8 x 1 connectors housing: diecast zinc nickel-plated

VE1101

Vibration diagnostic unit ATEX approval Group II, category 2D Group II, category 2G Spectral analysis / FFT Envelope-curve FFT Trend analysis Cable housing: diecast zinc

VE113A

Accessories VB / VE
Type Description Order no.

Parameter setting cable for efector octavis ifm electronic straight / straight 3 m Housing materials: PUR

E11572

USB/RS485 adapter cable ifm electronic straight / straight

E30098

Y connection cable ifm electronic 2 way Free from halogen 0.25 m Housing materials: TPU

E11664

Vibration monitors for vibration monitoring of machines and plants to ISO 10816 type VK
Type Description Drawing no. Order no.

Vibration monitor Connection via M12 connector Vibration monitor to DIN ISO 10816 Measuring range Veff: 0...25 mm/s Switching outputs: normally closed and analogue 4...20 mA PBT / PC / FPM / stainless steel 316L / 1.4404

VKV021

Vibration monitor Connection via M12 connector Vibration monitor to DIN ISO 10816 Measuring range Veff: 0...50 mm/s Switching outputs: normally closed and analogue 4...20 mA PBT / PC / FPM / stainless steel 316L / 1.4404

VKV022

www.ifm.com

185

Diagnostic systems

Accessories VK
Type Description Order no.

Protective cover with lead seal option for pressure sensors type PK for temperature sensors type TK for vibration monitor VK Housing materials: PP transparent

E30094

Diagnostic electronics - control cabinet modules for vibration diagnosis type VSE
Type Description Drawing no. Order no.

Diagnostic electronics for vibration sensors Ethernet interface Switching output, Analogue output Combicon connection PA

VSE002

Diagnostic electronics for vibration sensors 4 sensor inputs 0...10 mA Ethernet interface Switching output, Analogue output Combicon connection PA

VSE100

Accessories VSE
Type Description Order no.

Patch cable Cross-over patch cable Cable length 5 m

E30112

Vibration sensors for connection to external diagnostic electronics VSE - type VSA
Type Description Drawing no. Order no.

Vibration sensor for connection to external diagnostic electronics Connector housing: stainless steel 316L / 1.4404

VSA001

Vibration sensor for connection to external diagnostic electronics Cable with connector housing: stainless steel 316L / 1.4404

VSA002

www.ifm.com

186

Diagnostic systems

Type

Description

Drawing no.

Order no.

Vibration sensor for connection to external diagnostic electronics type VSExxx Cable housing: stainless steel 316L / 1.4404

VSA003

Accessories VSA
Type Description Order no.

conical washer 8.4 / 15 mm for efector octavis Housing materials: stainless steel 316Ti / 1.4571

E30115

Scale drawings - CAD download: www.ifm.com 1


58,2 46,4

3
62,2 46,4

M12 x1 36

14

14

36

5,3 6 1 M8 x1

20

M5

6 4

5,3

20

M5

37,6 10

37,6 10

5,3 5

LED

5,3

4 1: Programming buttons 2
58,2 46,4

27 M12 x1

M12 x1 36

14

6 4

5,3

20

M5

27 M8

37,6 10

5,3

www.ifm.com

M8x1

1: tightening torque 15 Nm

11

63,7 73,1

187

Diagnostic systems

Scale drawings - CAD download: www.ifm.com 5


25,4
103,4

7
M8x1,25

24

18,5

M12 x1 11,5 17

53

17

35,5

100

LEDs

1: conical angle = 90 8
22 18 5 14 M16x1,5 50 105 13

1: Ethernet interface 6

9
1500 35,5
114

12

LEDs

18 5,5

1 2

1: Ethernet interface, 2: Combicon plug with screw terminals (optional)

www.ifm.com

188

Diagnostic systems

189

190

Bus system AS-interface

Selection chart
Controllers, gateways and software AS-i repeaters AS-i power supplies I/O modules for control cabinets Field modules IP67 Field modules IP69K and accessories Module lower parts Pneumatic and actuator solutions Safety at Work AS-i sensors Combicon connectors Flat cable splitters and accessories Accessories Safety at Work Accessories lower parts and addressing units Accessories pneumatic components Accessories RFID Scale drawings - CAD download: www.ifm.com

Page
193 193 194 194 - 195 195 - 196 196 196 - 197 197 197 - 198 198 198 199 199 199 - 200 200 200 201 - 206

www.ifm.com

191

Bus system AS-interface

Manufacturer-independent standard. Worldwide acceptance as a wiring system. Communication from the sensor to the controller. Safety at Work for safety-related applications. Intelligent system solutions for special tasks.

Bus system AS-interface AS-interface (AS-i = actuator sensor interface) is a manufacturer-independent standard for the connection of actuators and sensors of the first field level. It is the only wiring system accepted worldwide. With 15 million slaves installed AS-i has been tried and tested as a low-cost feeder for all common fieldbuses for many years. The product range includes AS-i components for different areas from packaging and conveying via silo applications, machine tools, robotics and automation to the food industry and mobile vehicles. Safe The sophisticated AS-i technology and the extended diagnostic possibilities provide high reliability and machine uptime. Safety at Work is the extension of the AS-interface by safety-related components. Safety components up to the highest control category 4 to EN 954-1, SIL 3 to IEC 61508 and EN ISO 13849 - 1 / PL e can be connected to AS-i. Easy Due to the standardised system, the low wiring complexity and the quick connection technology, AS-i enables simple Plug & Play. The reduction of terminals leads to reduced documentation. Data and energy are jointly transmitted via a two-wire cable. The reverse polarity protected insulation displacement technology helps avoid errors. The modularity and the tree structure smoothly fit to the way the plant is put together. Cost-optimised Its the end result that matters: wiring complexity, documentation and set-up times are significantly reduced. The decentralisation of the AS-i participants leads to smaller and less expensive control cabinets. Simple diagnosis and a clear system design result in high machine uptime and avoid downtimes.

With Safety at Work AS-i also solves safetyrelated tasks.

Reduced cost: reduced wiring complexity for faster installation and fewer error sources.

www.ifm.com

192

Bus system AS-interface

Controllers, gateways and software


Type Number of AS-i masters Description Drawing no. Order no.

SmartLink DP AS-i gateway / Profibus DP Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised

AC1375

AS-i DP gateway Full master functions Graphic display Profibus DP interface Housing materials: aluminium / steel sheet galvanised

AC1376

AS-i DP gateway Full master functions Graphic display Profibus DP interface Housing materials: aluminium / steel sheet galvanised

AC1326

AS-i Ethernet / IP Controller E Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised

AC1327

AS-i Ethernet / IP Controller E Full master functions Graphic display Housing materials: aluminium / steel sheet galvanised

AC1337

AS-i controller E AS-i controller freely programmable Full master functions Graphic display Ethernet programming interface Housing materials: aluminium / steel sheet galvanised

AC1354

AS-i repeaters
Type Description Drawing no. Order no.

AS-i repeater Extension of the AS-i network by another 100 m One additional AS-i power supply necessary Combicon connection PA 6.6

AC2225

Passive AS-i bus termination Extension of the cable to a maximum of 200 m without additional repeater Improvement of the signal quality Monitoring of the supply voltage by means of LEDs

AC1147

AS-i tuner diagnostic module Extension of the cable to a maximum of 200 m without additional repeater Monitoring of the message quality Display of critical states by traffic light LEDs PBT

AC1146

www.ifm.com

193

Bus system AS-interface

AS-i power supplies


Type Output current AS-i [A] Description Drawing no. Order no.

0.95

Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling 30 Watt PC / ABS

AC1220

1.9

Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling 60 Watt PC / ABS

AC1221

2.8

Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling AlMg3 / steel sheet galvanised / polycarbonate

AC1236

Power supply AS-i Netzteil 100...240 V DC Integrated data decoupling AlMg3 / steel sheet / polycarbonate

AC1244

2x4

Power supply AS-i dual power supply 115/230 V AC 2 x AS-i Integrated data decoupling aluminium

AC1212

Power supply AS-i power supply 115/230 V AC Integrated data decoupling Jumper to deactivate the AS-i communication 240 watts aluminium / steel sheet galvanised

AC1218

I/O modules for control cabinets


Type Inputs / outputs Description Drawing no. Order no.

4 inputs

Active AS-i module String mounting possible Addressing socket Input supply from external PELV voltage source Version 2.1 with extended addressing mode Digital inputs Combicon connection PA

10

AC2254

4 outputs

Active AS-i module String mounting possible Addressing socket Version 2.1 Digital outputs Combicon connection PA

10

AC2252

4 inputs / 3 outputs

Active AS-i module String mounting possible Addressing socket Version 2.1 with extended addressing mode Digital inputs and outputs Combicon connection PA

10

AC2264

4 inputs / 4 outputs

Active AS-i module String mounting possible Addressing socket Version 2.1 Digital inputs and outputs Combicon connection PA

10

AC2251

4 inputs / 4 outputs; bidirectional

Active AS-i module String mounting possible Addressing socket External sensor supply PELV Version 2.1 Digital inputs and outputs Combicon connection PA

10

AC2257

4 inputs 4...20 mA

Active AS-i module AS-i profile S-7.3 4 analogue inputs 4...20 mA For the connection of 2-wire, 3-wire or 4-wire sensors Combicon connector for sensor connection PA 6.6

10

AC2216

2 inputs / 1 LED output

Active AS-i module Only suited for mechanical contacts

11

AC2729

www.ifm.com

194

Bus system AS-interface

Type

Inputs / outputs

Description

Drawing no.

Order no.

4 inputs / 3 outputs

Active AS-i module AS-i version 2.1 with extended addressing mode

12

AC2730

Field modules IP67


Type Inputs / outputs Description Drawing no. Order no.

4 inputs

Active ClassicLine module Version 2.11 and 3.0 with extended addressing mode Addressing socket Three orientations of the flat cable are possible Digital inputs Sockets M12 x 1 PA

13

AC5215

4 outputs

Active ClassicLine module Addressing socket Three orientations of the flat cable are possible Digital outputs Sockets M12 x 1 PA

13

AC5208

2 outputs / 2 inputs

Active ClassicLine module Version 2.11 and 3.0 with extended addressing mode Addressing socket Three orientations of the flat cable are possible Digital outputs and inputs Sockets M12 x 1 PA Active ClassicLine module Addressing socket Three orientations of the flat cable are possible Version 2.11 and 3.0 with extended addressing mode Digital inputs and outputs Sockets M12 x 1 PA Active ClassicLine module Only for operation with AS-i masters with the profile M4 Addressing socket Three orientations of the flat cable are possible Version 3.0 with extended addressing mode Digital inputs and outputs Sockets M12 x 1 PA

13

AC5214

4 inputs / 3 outputs; bidirectional

14

AC5204

4 inputs / 4 outputs; bidirectional

14

AC5235

2 pushbuttons / 2 LED displays

Active module upper parts AS-i illuminated pushbutton module Power supply via AS-i cable Colour inserts changeable PBT

15

AC2086

2 inputs 4...20 mA

Active ClassicLine module 2 analogue inputs 4...20 mA For the connection of 2-wire and 3-wire sensors Addressing socket Three orientations of the flat cable are possible PA

13

AC5222

4 inputs

Active CompactLine module Version 2.1 with extended addressing mode IR addressing possible Digital inputs Sockets M12 x 1 PUR

16

AC2457

4 inputs

Active CompactLine module IR addressing possible high-grade stainless steel Digital inputs Sockets M12 x 1 PA / stainless steel 316L / 1.4404

16

AC2451

4 outputs

Active CompactLine module IR addressing possible Digital outputs Sockets M12 x 1 PA

16

AC2417

2 inputs / 2 outputs

Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA

16

AC2411

www.ifm.com

195

Bus system AS-interface

Type

Inputs / outputs

Description

Drawing no.

Order no.

4 inputs / 4 outputs; bidirectional

Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA

17

AC2412

4 inputs / 4 outputs; bidirectional

Active CompactLine module IR addressing possible Digital inputs and outputs Sockets M12 x 1 PA / stainless steel 316L / 1.4404

17

AC2452

Field modules IP69K and accessories


Type Inputs / outputs Description Drawing no. Order no.

4 inputs / 3 outputs

Active ProcessLine module Version 2.1 with extended addressing mode Protection rating IP 69K high-grade stainless steel Digital inputs and outputs Sockets M12 x 1 high-grade stainless steel / Makrolon / O-ring: EPDM Active ProcessLine module Version 2.1 with extended addressing mode Protection rating IP 69K high-grade stainless steel Digital inputs Sockets M12 x 1 high-grade stainless steel / Makrolon / O-ring: EPDM Passive splitter box AS-i ProcessLine Protection rating IP 69K high-grade stainless steel AS-i and AUX splitter box for the connection of intelligent sensors/actuators Sockets M12 x 1 high-grade stainless steel / Makrolon

18

AC2904

8 digital inputs (2 Slaves)

19

AC2910

8-way splitter box

20

AC2900

4 inputs 4...20 mA

Active AS-i module 4 analogue inputs 4...20 mA For the connection of 2-wire and 3wire sensors Threaded bush: stainless steel 316L / 1.4404 / Makrolon / O-ring: EPDM

21

AC2916

AS-i / 24 V

FC splitter V4A AS-i voltage and external auxiliary voltage via the M12 socket Metal parts: stainless steel 316L / 1.4404 / Blanks: FPM / O-ring: EPDM

E70354

AS-i

FC splitter AS-i voltage via M12 socket Metal parts: stainless steel 316L / 1.4404 / Oring: EPDM / socket: PP GF30 / blade seal: TPE

E70454

Module lower parts


Type Inputs / outputs Description Drawing no. Order no.

FC coupling module

Module lower part flat cable AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT

22

AC5000

FC-E coupling module with external power supply

FC-E coupling module AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT

22

AC5003

FC coupling module

Module lower part flat cable stainless steel AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT / stainless steel

22

AC5014

FC-E coupling module with external power supply

FC-E coupling module stainless steel AS-i interface to module upper part Quick mounting technology for AS-i flat cable PBT / stainless steel

22

AC5015

www.ifm.com

196

Bus system AS-interface

Type

Inputs / outputs

Description

Drawing no.

Order no.

SC coupling module

Module lower part set AS-i interface to module upper part Screw terminal PBT

23

AC5031

Pneumatic and actuator solutions


Type Inputs / outputs Description Drawing no. Order no.

4 inputs / 2 outputs; AirBox supply via AS-i

AS-i AirBox 2 x 3/2-way slide valves free from overlapping Three orientations of the flat cable are possible AS-i flat cable connection Version 2.11 and 3.0 with extended addressing mode Addressing socket PA / POM AS-i AirBox 5/2-way slide valve free from overlapping Three orientations of the flat cable are possible AS-i flat cable connection Version 2.11 and 3.0 with extended addressing mode Addressing socket PA / POM

24

AC5228

4 inputs / 1 output ; AirBox supply via AS-i

25

AC5246

Safety at Work
Type Description Drawing no. Order no.

AS-i safety monitor Basic version 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON Screw terminal polyamide black

26

AC002S

AS-i safety monitor Extended functionality 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON Screw terminal

26

AC004S

AS-i safety monitor Extended functionality and integrated safe slave for triggering a safe AS-i output 1-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON V3.0 Screw terminal polyamide black AS-i safety monitor Extended functionality and integrated safe slave for triggering a safe AS-i output 2-channel Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e Configuration and setup by configuration software ASIMON V3.0 Screw terminal

27

AC031S

27

AC032S

Safe active AS-i module Control category 4 according to EN954-1 and IEC 61508 / SIL 3 For the connection of mechanical contacts Combicon connection

28

AC009S

Safe active AS-i output module Control category 4 to EN954-1, IEC 61508 / SIL 3 and EN ISO 13849 - 1 PL e for the safe triggering of actuators Combicon connection

29

AC030S

Safe active AS-i module Connection via M12x1 sockets or cage clamps Control category 4 according to EN954-1 and IEC 61508 / SIL 3 Version 2.1 For connection of an electro-sensitive protective equipment (ESPE) type 4 to EN 61496-1 AS-i interface to FC-E lower parts

30

AC007S

Safe AS-i input module IR addressing possible AS-i version 2.1 Performance Level e to EN ISO 13849-1 for the connection of mechanical contacts Sockets M12 x 1 PBT

31

AC005S

www.ifm.com

197

Bus system AS-interface

Type

Description

Drawing no.

Order no.

Illuminated E-STOP with integrated AS-i connection Connector M12 x 1 AS-i interface via AS-i flat cable IP 67 foolproof E-STOP to EN ISO 13850 / EN 418 Pull to reset

32

AC010S

safe AS-i e-stop operating unit with integrated AS-i connection AS-i interface via M12 x 1 connector fool-proof E-STOP to EN ISO 13850 / EN 418 Pull to reset interchangeable button inserts

33

AC012S

AS-i safety PCB Connection of mechanical contact and LED components Certification according to EN 954-1 / category 4 and IEC 61508 / SIL 3

11

AC015S

AS-i sensors
Type Description Drawing no. Order no.

Read/write head DTSLF AARWASUS01 with integrated AS-i slave profile 7.4 M12 connector PA

34

DTA100

Read/write head DTSLF DCRWASUS01 with integrated AS-i slave profile 7.4 M12 connector housing: PPE / Metal parts: diecast zinc / brass nickel-plated

35

DTA300

Combicon connectors
Type Description Order no.

Combicon connector with screw terminals 4-pole Housing materials: current carrying parts: copper alloy tin-plated Pack quantity: 6

E70230

Combicon connector with screw terminals 4-pole Housing materials: current carrying parts: copper alloy tin-plated Pack quantity: 100

E70231

www.ifm.com

198

Bus system AS-interface

Flat cable splitters and accessories


Type Description Order no.

FC splitter AS-i voltage via M12 socket Housing materials: Metal parts: stainless steel 316L / 1.4404 / O-ring: EPDM / socket: PP GF30 / blade seal: TPE

E70454

FC splitter V4A AS-i voltage and external auxiliary voltage via the M12 socket Housing materials: Metal parts: stainless steel 316L / 1.4404 / Blanks: FPM / O-ring: EPDM

E70354

FC insulation displacement connector Socket M12 - AS-i flat cable Housing materials: PA

E70096

Protective cap M12 for M12 sockets of ClassicLine modules, CompactLine modules and AirBoxes Housing materials: PA black

E73004

Protective cap M12 for M12 socket to cover the unused inputs and outputs on the module; for unused inputs of splitter boxes for ProcessLine modules Housing materials: PVC

E70297

Accessories Safety at Work


Type Description Order no.

Connection cable PC / AS-i safety monitor Parameter setting cable PC / AS-i safety monitor Western connector RJ 45 8 poles / DSub socket 9 poles 2.5 m

E7001S

bridging plug for safety modules Housing materials: PUR

E7005S

Accessories lower parts and addressing units


Type Description Order no.

AS-i addressing unit AS-i version 2.1 with extended addressing mode

AC1144

Addressing cable for AS-i slaves 1.6 m

E70213

Programming cable for controller E Western connector RJ11 6 poles / D-Sub socket 9 poles 1.55 m

E70320

Module lower part set Screw terminal Housing materials: PBT

AC5031

www.ifm.com

199

Bus system AS-interface

Type

Description

Order no.

Use of the lower part as branching box Housing materials: plastics

AC3000

AS-i flat cable reverse polarity protection due to special shape for use in isolation displacement connector technology for FC lower parts and compact modules

AC4000

AS-i flat cable reverse polarity protection due to special shape for use in isolation displacement connector technology for FC lower parts and compact modules

AC4002

AS-i flat cable for the food industry reverse polarity protection due to special shape 100 m

AC4007

AS-i flat cable for the food industry reverse polarity protection due to special shape 100 m

AC4008

JOKARI flat cable stripping tool

E70062

Flat cable seal Housing materials: ULTRAMID / sealing: NBR Pack quantity: 10

E70413

Accessories pneumatic components


Type Description Order no.

Silencer Housing materials: connection piece: PP / filter: PE

E75232

Accessories RFID
Type Description Order no.

ID tag ID-TAG/TRIANGEL HOUSING/01 with ID tag E80301 Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005)

E80302

ID tag ID-TAG/D20x2.15/01 20 x 2.15 mm Housing materials: polycarbonate black

E80317

ID tag ID-TAG/ISO-Card/01 54 x 86 x 1 mm Housing materials: PVC white

E80320

www.ifm.com

200

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 1


85 62

4
86 62

124 138

LED

LED

124 131

57 68

97 107

5 2
86
44

83

62

M12 x1

124 131

LED

LED
90

LED 97 107
4

1: tune button, 2: mode selector 3


86 62

LED 124 131

90

LED

LED

45

100

97 107

www.ifm.com

201

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 7 11

21

LED

129 136

44

32

9 10 10

50

136 144

12
88

8
118,5 113

120

13
134

9
91

14
124 131

Jumper LED

96 107

10
25
105

LEDs

1: Addressing socket

www.ifm.com

202

35,5

114

44

UU U

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 15


80

19
137,3 80

30

16
118

45

M12 x1

LED

43,6

17 24

20
137,3 80

36

39 60

LED

M12 x1

107

FE

4,5

17
152

M12 x1
17 24

43,6

21
137,3
36 39 60

80

LED

M12 x1

18
137,3 80

M12 x1
1 M12 x1

43,6

M12 x1

LED

43,6

www.ifm.com

M12 x1

107

FE

4,5

M12 x1

203

M12 x1

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 22


80

25
85 20 35 9,6
2

31 45

0 1

66

23
82,5 80 40
1

33

35 9,6

26
45 120

5,3 7

31 45

66

24
LED
85

27
0 1 2

35,5

104

45 91 108

91,2

120

4 0 1

50

91 108

5,3

105,9

www.ifm.com

204

40

50

82,6

35,5

102

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 28


25 105

32

108

35,5

LEDs

93,5

M12 x1

1: Addressing socket
58,5
UU U

29

25

105

66,5

80

33
108 35,5

105

1
207

56

30

80

1: Addressing socket, 2: LED

72

120

45,5 80

34
24 49,4 56 LED 1 2 55 53,5 17 41

111

70

5,5

M12x1

4,2

M12 x1

17

4,5

31
80
2

25

M12 x1 LED

1: integrated antenna , 2: tag positioning mark (middle of the antenna)


45

www.ifm.com

72

56

105

205

Bus system AS-interface

Scale drawings - CAD download: www.ifm.com 35


112 92 9,3 5,5 40 40 20

M12 x1

65 80
7,5

65

17

LED

1: mounting on DIN rail

www.ifm.com

206

Bus system AS-interface

207

208

Multicode reading systems

Selection chart
Multicode reader Accessories Scale drawings - CAD download: www.ifm.com

Page
211 211 211

www.ifm.com

209

Multicode reading systems

Orientation-independent identification of 1D and 2D codes. Very small housing for flexible use. Simple, menu-guided parameter setting. Integrated lighting. High reading reliability even with soiled / damaged codes.

Multicode reader The ECC200 Data Matrix code is becoming more and more popular throughout industry alongside familiar barcodes. In this code lots of information can be stored in a very small space and read using the compact multicode reader. The industrially compatible mounting and wiring technology as well as the standardised process interfaces RS-232, Ethernet TCP/IP and EtherNet/IP enable easy and quick integration into the industrial control technology. Applications can be found in many different industrial areas: from the product tracking and production control to product identification. Orientation-independent reading Independent of the orientation and the number of codes, the high-performance algorithms automatically decode 1D or 2D codes. The optimisation parameters of the codes and functions of the multicode reader undergo continuous development and are made available as upgrades. Code comparison in the sensor Complex application programming is no longer necessary due to adjustable, selective code identification and comparison in the sensor. This allows a defined number of characters within a code to be checked and signalled via the switching output if they match. Reliable identification of 1D and 2D codes In addition to the automatic exposure setting, manual adjustment is also possible. So optimum results are achieved even with highly reflective metal surfaces. For evaluation of the code quality parameter, ISO / IEC 15415 or 16022 can be used. The Data Matrix code The Data Matrix code is a two-dimensional code containing much more information with the same structure size than codes such as bar codes or stacked codes. Several thousand characters can be stored in one code. An important feature of the Data Matrix code is the high reading reliability. If the code is soiled or damaged, the intelligent system can completely recompose the information from different segments again. The Data Matrix code can be structured differently and is variable in shape and size. The size can cover 1 x 1 mm to 100 x 100 mm.

Lose no time: the multicode reader can be configured in a few minutes and is then ready for use. Only five guided steps are necessary for the multicode reader to be ready for operation.

Whether printed on paper, graved by laser or dot-peened on metal: reliable detection of the code, independent of the sensor orientation.

www.ifm.com

210

Multicode reading systems

Multicode reader
Type Dimensions Max. field of view size [mm] Type of light LED Motion speed int. / ext. lighting [m/s] Process interface Drawing no. Order no.

[mm]

M12 plug, 8 poles M12 socket, 4 poles


60 x 42 x 53.5 68 x 50 red light 3/5 Ethernet TCP/IP, EtherNet/IP, RS-232 1 O2I100

Accessories
Type Description Order no.

Operating software O2I for multicode reader Create and manage application-specific configurations Monitor mode for set-up and service Service reports for statistical evaluations

E2I200

Plastic protective pane for the food industry O2D / O2I Housing materials: housing: diecast zinc black / lens: PMMA

E21166

Mounting set O2D, O2M, O2I Clamp mounting rod mounting 12 mm Housing materials: fixture: stainless steel / clamp: stainless steel

E2D110

mounting rod 14 / M12 Length: 130 mm straight Housing materials: stainless steel 316Ti / 1.4571

E20939

mounting rod 14 / M12 Length: 200 mm angled Housing materials: stainless steel 316Ti / 1.4571

E20941

Scale drawings - CAD download: www.ifm.com 1


42 21 1 53,5 2

57 60

45

24,5

80

4,3

20,5

9,5 7

19,7 33 44

M12x1 M12x1

1: display, 2: Focus setting, 3: Centre of the lens axes

www.ifm.com

19

211

212

RF-identification systems

Selection chart
RFID systems Accessories Wiring diagrams Scale drawings - CAD download: www.ifm.com

Page
215 215 215 216

www.ifm.com

213

RF-identification systems

RFID write and read heads and a selection of tags. Industrial ident system using the 125 kHz range. Up to 31 compact read / write heads per evaluation module. Read or write up to 15 bits within 20 milliseconds. Data interface to high end systems; Profibus, DeviceNet, ethernet and others.

RF-identification systems The constant increase of the degree of automation in modern production plants is increasingly supported by identification systems. Their tasks include for example the control or release of production steps or the assignment of information about each product. The RF identification system (Radio Frequency Identification System) from ifm electronic is a compact and easy alternative for applications in which for example optical identification is not possible due to the ambient conditions. It is also the first RF identification system for AS-interface worldwide. It allows reading and writing of code carriers (ID tags), benefiting from the advantages of AS-interface. It can be integrated into existing AS-I networks without problem and is immediately ready for operation. For reading, the RF identification system uses the AS-i analogue protocol 7.4 for data transfer. Special software modules are not required. Up to 31 read/write heads can be connected to one AS-i master. The read/write head stores transmission errors which can be retrieved for a targeted fault analysis. Antenna, electronics and AS-interface are integrated in a compact housing. The voltage is supplied via the AS-i network via a rotatable M12 connector. No additional operating voltage required. The ID TAG (transponder) provides flexible mounting options for workpiece carriers, tanks, etc., ... Operating principle The RFID system from ifm electronic generates a 125 kHz electromagnetic field for reading and writing of data. The electromagnetic field emitted by the antenna induces voltage in the passive ID tag (transformer principle). This activates the ID tag (transponder) which returns its code. Processing of the code and transmission to the AS-interface are carried out in the read / write head. Advantages: reliable data transmission in dynamic reading processes and ID tags for each application.

The read / write heads exchange data with the passive ID tags at a maximum distance of 20 mm. The ID tag provides flexibility for different types of mounting.

The ID tag is mounted to tanks or workpiece carriers in the tag fixture or alternatively by direct mounting using an M5 grub screw.

www.ifm.com

214

RF-identification systems

RFID systems
Type Dimensions Travel speed read / write [m/s] Process interface Wiring diagram no. Drawing no. Order no.

[mm]

M12 connector
55 x 24 x 41 read: 0.5 (distance to the ID tag 15 mm) write: only static AS-i 1 1 DTA100

92 x 80 x 40

read: 0.5 (distance to the ID tag 40 mm) write: only static

AS-i

DTA300

Accessories
Type Description Order no.

ID tag ID-TAG/TRIANGEL HOUSING/01 with ID tag E80301 Housing materials: PBT orange (RAL 2003) / PA black (RAL 9005)

E80302

ID tag ID-TAG/D20x2.15/01 20 x 2.15 mm Housing materials: polycarbonate black

E80317

ID tag ID-TAG/ISO-Card/01 54 x 86 x 1 mm Housing materials: PVC white

E80320

Dovetail clamp for type DTS, O4, O5 Housing materials: AlMgSi0.5

E21088

Wiring diagrams
1

AS-i+

AS-i

www.ifm.com

215

RF-identification systems

Scale drawings - CAD download: www.ifm.com 1


24 LED 1 2 55 53,5 17 56 41 9,3 5,5 40

2
112 92 40 20

70

5,5

M12 x1

4,2

M12 x1

17

4,5

65 80
7,5

65

17

LED

2 5

1: mounting on DIN rail

1: integrated antenna , 2: tag positioning mark (middle of the antenna)

www.ifm.com

216

RF-identification systems

217

218

Power supplies

Selection chart
Switched-mode power supplies Scale drawings - CAD download: www.ifm.com

Page
221 221 - 222

www.ifm.com

219

Power supplies

Range of regulated 24 V DC switched mode power supplies. Both 1-ph and 3-ph primary side available. From 1 amp up to 40 amp load. Robust metal housing, easy and safe DIN rail mounting. Robust metal housings with 35 mm rail mounting.

Power supplies They may be unglamorous and unobtrusive, but without them it would not be possible to operate an electronic system. Power supplies are essential. ifm offers lowcost transformer power supplies but also powerful switched-mode power supplies for different applications. Transformer power supplies Transformer power supplies provide a low voltage, normally 24 V DC. A transformer according to DIN 0551 ensures a safe electrical separation from mains voltage and low voltage. The output voltage can be regulated ( 5 %) or smoothed by means of capacitors. The different designs and output powers allow adaptation to diverse operating conditions. Switched-mode power supplies Primary switched-mode power supplies are a compact and economical solution to supply sensors and actuators. As opposed to conventional transformer power supplies with regulated output voltage they need no heavy transformers so that there are fewer iron and copper losses. They are therefore distinguished by a very high degree of efficiency of up to 92 %. Due to the operating principle by means of high frequency transformers switched-mode power supplies are much smaller and lighter than transformer power supplies with identical power. Nevertheless they guarantee an electrical separation. Furthermore, they offer a wide input voltage range as standard for worldwide use. Power reserves Mains fluctuations up to 15 % and mains interference are compensated for. Even mains voltage dips of a few milliseconds are compensated for, the output voltage is completely maintained. An active inrush current limitation reduces the inrush current by means of a fixed resistor which is bridged after start up. The outputs are protected against short circuits and overload. Special output characteristics allow a current which can be up to 1.7 higher than the nominal current without switch-off with the voltage being reduced at the same time. The dimensioning of the components allows a 20 to 25 % higher output current for a short time. This power reserve is provided by all power supplies as from 2.5 A for a period of one minute. At an operating temperature of up to 45 C this power is available continuously.

Suitable for the application: ifm provides power supplies in different power classes.

www.ifm.com

220

Power supplies

Switched-mode power supplies


Type Current [A] 10 Output voltage [V] 24...28 DC (2%) Nominal voltage [V] 115 / 230 AC Efficiency typ. [%] 90 Drawing no. 1 Order no.

DN2013

20

24...28 DC (2%)

230 AC

91

DN2014

24...28 DC (2%)

3 x 400...500 AC

89

DN2032

10

24...28 DC (2%)

3 x 400...500 AC

90

DN2033

30 40

24...28 DC (2%) 24...28 DC (2%)

3 x 400...500 AC 3 x 400...500 AC

93 92.5

5 6

DN2036 DN2035

1.25 2.5

24...28 24...28

84 88

7 7

DN1030 DN1031

2.5 5

24...28 24...28

87.1 88.9

8 8

DN3011 DN3012

Scale drawings - CAD download: www.ifm.com 1


120 89

2
220

124 131

LED

107 4

227 LED

89

107 4

www.ifm.com

124 131

221

Power supplies

Scale drawings - CAD download: www.ifm.com 3


73 103

6
275

124 131

LED

282 LED 89

4
90

1 2 3
131 124 107 4

4 5 6
110 121

122

1: LED red, 2: reset push button, 3: jumper overload performance, 4: jumper single/parallel operation, 5: with pot., 6: LED green 5
240

90

LED

45

100

1: with pot. 8
124 131

247 LED 89

LEDs 1

129 136

50

136 144

1: with pot.
107 4

www.ifm.com

222

124 131

Power supplies

223

224

Connection technology

Selection chart
Sockets for industrial applications Sockets for industrial applications Cable plugs for industrial applications Connectors for oils and coolants Connectors for oils and coolants Connectors for electromagnetric fields Connectors for hygienic and wet areas Connectors for hazardous areas Scale drawings - CAD download: www.ifm.com

Page
227 227 - 228 228 229 229 229 230 - 231 231 231 - 234

www.ifm.com

225

Connection technology

Complete product range: sockets, plugs, jumper cables, splitter boxes. Various cable materials for different applications. High-quality materials for maximum reliability. ecolink series with innovative quality features. Integrated LEDs for easy diagnosis.

Connection technology With a wide variety of different sensor designs ifm electronic offers a wide range of high quality connectors. The choice of types covers common M8, M12, M18 types through to valve plugs. The ecolink connectors (order no. EVxxxx) offer additional quality features. ecolink - a new dimension in connection technology Due to the special installation of a mechanical end stop the O-ring is always correctly compressed and so permanently maintains its sealing function. The connector remains securely positioned on the unit even in case of extreme vibration and impacts. Novel design and a transparent black housing ensure that even in bright lighting conditions the LEDs are more clearly visible than with the clear transparent versions. For industrial applications: High-quality materials suited to the requirements in industrial environments. Largely resistant to oils and greases. For hygienic and wet areas: PVC housing and cable, gold-plated contacts and high-grade stainless steel nuts are the optimum choice for long life. For oils and coolants: With PUR housings, cable with full PUR sheaths, Viton seals and gold contacts, these products set new standards for the harsh operating conditions of the machine tool industry. For hazardous areas Connection technology for ATEX categories 2D, 3D and 3G. With the EC type examination certificate for components from DEKRA EXAM the connection technology meets the strictest requirements. For welding applications Halogen-free PUR cables prevent burning-in of weld spatter; teflon-coated coupling nuts prevent weld spatter sticking. The cables are also suited for drag chains and torsional movements. For sensors in robust applications: The saw tooth contoured vibration protection secures against strong shocks and vibrations. The high protection rating, wide temperature range and high-quality housing materials (high-grade stainless steel, TPU) ensure permanent safe connection in harsh environments. www.ifm.com
Maximum operational reliability due to the new vibration protection with end stop. Black, transparent housing for optimum LED visibility.

226

Connection technology

Sockets for industrial applications


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M8, 3-pole, 3-wire, straight


5 m black PUR cable 10 m black PUR cable 3 x 0.25 mm2, 3.7 mm 3 x 0.25 mm2, 3.7 mm TPU / brass TPU / brass 50 AC 60 DC 50 AC 60 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 1 1 EVC142 EVC143

Socket M8, 3-pole, 3-wire, angled


5 m black PUR cable 10 m black PUR cable 3 x 0.25 mm2, 3.7 mm 3 x 0.25 mm2, 3.7 mm TPU / brass TPU / brass 50 AC 60 DC 50 AC 60 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 2 2 EVC145 EVC146

Socket M8, 3-pole, 3-wire, angled, LED, PNP


5 m black PUR cable 10 m black PUR cable 3 x 0.25 mm2, 3.7 mm 3 x 0.25 mm2, 3.7 mm TPU / brass TPU / brass 10...36 DC 10...36 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K green / yellow green / yellow 3 3 EVC148 EVC149

Socket M8, 4-pole, 4-wire, straight


5 m black PUR cable 10 m black PUR cable 4 x 0.25 mm2, 3.7 mm 4 x 0.25 mm2, 3.7 mm TPU / brass TPU / brass 50 AC 60 DC 50 AC 60 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 4 4 EVC151 EVC152

Socket M8, 4-pole, 3-wire, angled


5 m black PUR cable 10 m black PUR cable 4 x 0.25 mm2, 3.7 mm 4 x 0.25 mm2, 3.7 mm TPU / brass TPU / brass 50 AC 60 DC 50 AC 60 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 5 5 EVC154 EVC155

Sockets for industrial applications


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M12, 4-pole, angled


wirable ...0.75 mm2 ( 4...6 mm) PA / brass 250 AC/DC -25...100 IP68 6 E11509

Socket M12, 4-pole, straight


wirable ...0.75 mm2 ( 4...6 mm) PA / brass 250 AC/DC -25...100 IP68 7 E11508

Socket M12, 4/5-pole, 4-wire, angled


5 m black PUR cable 10 m black PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 8 8 EVC005 EVC006

Socket M12, 4/5-pole, 4-wire, straight


5 m black PUR cable 10 m black PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 9 9 EVC002 EVC003

www.ifm.com

227

Connection technology

Type

Cable

Wire specification

Material housing/ nut

U [V]

Ta [C]

Protection

LEDs

Drawing no.

Order no.

socket M12, 8-pole, 7-wire + screen


2 m orange PUR cable 7 x 0.25 mm2 + screen TPU / brass 30 AC 36 DC -25...90 IP67 10 E20738

socket M12, 8-pole, 8-wire, for temperature sensors TR 8...


5 m black PUR cable 8 x 0.25 mm2, 6.2 mm PUR / brass 30 AC 36 DC -25...80 IP68 11 E11232

Socket M16, 14-pole, 12-wire, angled


5 m black PUR cable 10 x 0.25 mm2 + 2 x 0.34 mm2, 7.5 mm PUR / brass 30 DC -25...90 IP67 12 E11697

socket 1/2, 2-pole + PE, 3-wire


5 m yellow PVC cable 3 x 0.34 mm2, 5.2 mm TPU / brass 250 AC 300 DC -25...90 IP67 13 E10200

5 m yellow PVC cable

3 x AWG22, 5.2 mm

TPU / brass

250 AC 300 DC

-25...90

IP67

14

E10191

socket 1/2, 5-pole, 4-wire


5 m black PUR cable 10 m black PUR cable 4 x 0.34 mm2, 4.7 mm 4 x 0.34 mm2, 4.7 mm TPU / brass TPU / brass 300 AC 300 AC -25...90 -25...90 IP67 IP67 15 15 E11248 E11249

Cable plugs for industrial applications


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Plug M12, 4-pole, angled


wirable ...0.75 mm2 ( 4...6 mm) PA / brass 250 AC/DC -25...100 IP68 16 E11505

Plug M12, 4-pole, straight


wirable ...0.75 mm2 ( 4...6 mm) PA / brass 250 AC/DC -25...100 IP68 17 E11504

Plug M12, 5-pole, 5-wire, straight


2 m black PUR cable 5 x 0.34 mm2, 4.9 mm TPU / brass 30 AC 36 DC -25...90 IP67 / IP68 / IP69K 18 EVC094

www.ifm.com

228

Connection technology

Connectors for oils and coolants


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M12, 4/5-pole, 4-wire, angled


5 m black PUR cable 10 m black PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 8 8 EVC005 EVC006

Socket M12, 4/5-pole, 4-wire, straight


5 m black PUR cable 10 m black PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 9 9 EVC002 EVC003

Connectors for oils and coolants


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

M12 splitter box for 1 signal


10 m black PUR cable 4 x 0.34 mm2 + 3 x 1 mm2, 7.5 mm PA 10...30 DC -25...80 IP67 green / 4 x yellow 19 EBC027

10 m black PUR cable

6 x 0.34 mm2 + 3 x 1 mm2, 7.8 mm

PA

10...30 DC

-25...80

IP67

green / 6 x yellow

20

EBC031

10 m black PUR cable

8 x 0.34 mm2 + 3 x 0.75 mm2, 8.2 mm

PA

10...30 DC

-25...80

IP67

green / 8 x yellow

21

EBC035

Connectors for electromagnetric fields


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M12, 4-pole, 4-wire, angled


5 m grey PUR cable 10 m grey PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 8 8 EVW005 EVW006

Socket M12, 4-pole, 4-wire, straight


5 m grey PUR cable 10 m grey PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 250 AC 300 DC 250 AC 300 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 9 9 EVW002 EVW003

Socket M12, 4-pole, 4-wire, angled, LED, PNP


5 m grey PUR cable 10 m grey PUR cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm TPU / brass TPU / brass 10...36 DC 10...36 DC -25...90 -25...90 IP67 / IP68 / IP69K IP67 / IP68 / IP69K green / 2 x yellow green / 2 x yellow 22 22 EVW008 EVW009

www.ifm.com

229

Connection technology

Connectors for hygienic and wet areas


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M8, 3-pole, 3-wire, angled


5 m orange PVC cable 10 m orange PVC cable 3 x 0.25 mm2, 5 mm 3 x 0.25 mm2, 5 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 60 AC 75 DC 60 AC 75 DC -25...85 -25...85 IP68 IP68 23 23 E11498 E11499

Socket M8, 3-pole, 3-wire, straight


5 m orange PVC cable 10 m orange PVC cable 3 x 0.25 mm2, 5 mm 3 x 0.25 mm2, 5 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 60 AC 75 DC 60 AC 75 DC -25...85 -25...85 IP68 IP68 24 24 E11495 E11496

Socket M8, 4-pole, 4-wire, angled


5 m orange PVC cable 10 m orange PVC cable 4 x 0.25 mm2, 5 mm 4 x 0.25 mm2, 5 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 60 AC 75 DC 60 AC 75 DC -25...90 -25...90 IP68 IP68 25 25 E11220 E11221

Socket M8, 4-pole, 4-wire, straight


5 m orange PVC cable 10 m orange PVC cable 4 x 0.25 mm2, 5 mm 4 x 0.25 mm2, 5 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 60 AC 75 DC 60 AC 75 DC -25...90 -25...90 IP68 IP68 26 26 E11223 E11224

Socket M12, 4-pole, 4-wire, angled


5 m orange PVC cable 10 m orange PVC cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 250 AC 300 DC 250 AC 300 DC -25...100 -25...100 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 27 27 EVT004 EVT005

Socket M12, 4-pole, 4-wire, straight


5 m orange PVC cable 10 m orange PVC cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 250 AC 300 DC 250 AC 300 DC -25...100 -25...100 IP67 / IP68 / IP69K IP67 / IP68 / IP69K 28 28 EVT001 EVT002

Socket M12, 4-pole, 4-wire, angled, LED, PNP


5 m orange PVC cable 10 m orange PVC cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 10...36 DC 10...36 DC -25...100 -25...100 IP67 / IP68 / IP69K IP67 / IP68 / IP69K green / 2 x yellow green / 2 x yellow 29 29 EVT007 EVT008

Jumper M12, 4-pole, 4-wire, straight / straight


0.3 m orange PVC cable 0.6 m orange PVC cable 1 m orange PVC cable 2 m orange PVC cable 5 m orange PVC cable 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm 4 x 0.34 mm2, 4.9 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 250 AC 300 DC 250 AC 300 DC 250 AC 300 DC 250 AC 300 DC 250 AC 300 DC -25...100 -25...100 -25...100 -25...100 -25...100 IP67 / IP68 / IP69K IP67 / IP68 / IP69K IP67 / IP68 / IP69K IP67 / IP68 / IP69K IP67 / IP68 / IP69K 30 30 30 30 30 EVT040 EVT041 EVT042 EVT043 EVT044

Socket M12, 5-pole, 5-wire, angled


5 m orange PVC cable 5 x 0.34 mm2, 5.1 mm PVC / st. steel 316L / 1.4404 30 AC 36 DC -25...100 IP67 / IP68 / IP69K 31 EVT013

www.ifm.com

230

Connection technology

Type

Cable

Wire specification

Material housing/ nut

U [V]

Ta [C]

Protection

LEDs

Drawing no.

Order no.

Socket M12, 5-pole, 5-wire, straight


5 m orange PVC cable 5 x 0.34 mm2, 5.1 mm PVC / st. steel 316L / 1.4404 30 AC 36 DC -25...100 IP67 / IP68 / IP69K 32 EVT010

Jumper M12, 5-pole, 5-wire, straight / straight


0.3 m orange PVC cable 1 m orange PVC cable 2 m orange PVC cable 5 m orange PVC cable 5 x 0.34 mm2, 5.1 mm 5 x 0.34 mm2, 5.1 mm 5 x 0.34 mm2, 5.1 mm 5 x 0.34 mm2, 5.1 mm PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 PVC / st. steel 316L / 1.4404 30 AC 36 DC 30 AC 36 DC 30 AC 36 DC 30 AC 36 DC -25...100 -25...100 -25...100 -25...100 IP67 / IP68 / IP69K IP67 / IP68 / IP69K IP67 / IP68 / IP69K IP67 / IP68 / IP69K 33 33 33 33 EVT058 EVT060 EVT061 EVT062

Connectors for hazardous areas


Type Cable Wire specification Material housing/ nut U [V] Ta [C] Protection LEDs Drawing no. Order no.

Socket M12, 4-pole, 4-wire, angled


5 m blue PUR cable 4 x 0.34 mm2, 4.9 mm TPU / brass ...30 DC -25...90 IP67 8 ENC05A

Socket M12, 4-pole, 4-wire, straight


5 m blue PUR cable 4 x 0.34 mm2, 4.9 mm TPU / brass ...30 DC -25...90 IP67 9 ENC02A

Socket M12, 5-pole, 5-wire, angled


5 m blue PUR cable 5 x 0.34 mm2, 4.9 mm TPU / brass ...30 DC -25...90 IP67 34 ENC11A

Scale drawings - CAD download: www.ifm.com 1 3

10

31 M8x1

10 25,5

19

M8x1

LED

10 25,5

19

10 9

31

M8x1

M8x1

www.ifm.com

231

Connection technology

Scale drawings - CAD download: www.ifm.com 5 11

15 10 25,5 19

28

M8x1

9 M12 x1 10,5

12
20 20 35 45

30

18

38
M16x1

M12 x1

13

49

15

27

18

46 39

M12 x1

G1 2 10,5

14

15,5

26,5
15 42

M12x1

36,5

14

G1 2

15

15 15,5 14

10,5

27

M12x1

45

12

"-20UNF 10,5

10

16

20

39

42

15
31 18

M12 x1

43
M12 x1 15

www.ifm.com

232

Connection technology

Scale drawings - CAD download: www.ifm.com 17 21


60
20 52
7 8

34

PWR

152

73

18

M12 x1

M12x1

15,5

14

4,7

28,5 39

7,5

19

22

22 18

M12x1

49,5

15,5

4,5
26,5

60
36,5

M12x1

3 LED

14

34

PWR 3 4

118,2

M12x1

73

23

4,7

4,5

10

28,5 39

7,5

18

22 18

M8 x1

28

20

24

60
31
5 6

10

34

M8 x1
PWR 3 4

125

M12x1

73

25

4,7

28,5 39

7,5

4,5

18 10

22 18

M8 x1

28

www.ifm.com

233

Connection technology

Scale drawings - CAD download: www.ifm.com 26 31

26,5 15,5 14 14 15,5 45 14 M12 x1 15,5 49 L 45 15,5 15,5 26,5 M12x1 36,5 14 31 36,5 14 10

M12x1 9

M8 x1

27

32

26,5 15,5 14 M12 x1

M12x1

28

36,5

33

14 15,5

M12 x1 15,5

M12 x1

45

29

34

26,5

M12x1

36,5

LED

14

30

M12 x1 15,5

14

14

M12 x1 15,5

49

45

www.ifm.com

234

Connection technology

235

ifm worldwide addresses

Argentina
ifm electronic s.r.l. Manuela Senz 323 5 piso, oficina 3 C1107BPA - Puerto Madero Buenos Aires, Argentina Tel. (011) 5353-3436 Fax (011) 5353-3436 Interior 0810-345-3436 info.ar@ifm.com www.ifm.com/ar

Brazil
ifm electronic Ltda. Rua Eleonora Cintra, 140 Jardim Analia Franco 03337-000 So Paulo/SP Tel. +55-11-2672-1730 Fax +55-11-2673-3501 info.br@ifm.com www.ifm.com/br

Croatia
ifm electronic gmbh Wienerbergstr. 41 Gebude E A-1120 Wien Tel. +43 / 1 / 617 45 00 Fax +43 / 1 / 617 45 00 10 info.hr@ifm.com www.ifm.com/hr

France
ifm electronic Sige : Savoie Technolac BP226 73374 Le Bourget du Lac Agence commerciale : Immeuble Uranus 1-3 rue Jean Richepin 93192 NOISY LE GRAND CEDEX Tl: 0820 22 30 01 Fax: 0820 22 22 04 info.fr@ifm.com www.ifm.com/fr

Ireland
ifm electronic (Ireland) Ltd. No. 7, The Courtyard Kilcarbery Business Park New Nangor Road Clondalkin Dublin 22 Tel. +353 / 1 / 413 60 66 Fax +353 / 1 / 457 38 28 sales_ie@ifm.com www.ifm.com/ie

Bulgaria
ifm electronic eood ul. Slatinska Nr. 92 A, ap. 2/3 1574 SOFIA Tel. +359 2 807 59 69 Fax. +359 2 807 59 60 info.bg@ifm.com

Czech Republic
ifm electronic spol.s.r.o. U Kku 571 252 43 Prague Tel. +420 / 2 / 67 990 211 Fax +420 / 2 / 67 750 180 info.cz@ifm.com www.ifm.com/cz

Australia
ifm efector pty ltd. P.O. Box 4084 Suite 3, 745 Springvale Road Mulgrave VIC 3170 Tel. 1300 365 088 Fax 1300 365 070 sales.au@ifm.com www.ifmefector.com.au

Israel
Astragal Ltd. 3, Hashikma Str. Azur 58001 P.O. Box 99 Azur 58190 Tel. +972 / 3 / 5 59 16 60 Fax +972 / 3 / 5 59 23 40 astragal@astragal.co.il www.astragal.co.il

Germany
ifm electronic gmbh Friedrichstr. 1 45128 Essen Tel. +49 201 24 22 0 Fax +49 201 24 22 12 00 info@ifm.com www.ifm.com/de

Canada
ifm efector Canada Inc. 700 Dorval Drive/Corporate Centre Oakville; L6K3V3 Ontario Tel. +1-800-441-8246 Fax +1-800-329-0436 info@ifmefector.ca www.ifmefector.ca

Denmark
ifm electronic a/s Ringager 4A, 1.sal tv. 2605 Brndby Tel. +45 70 20 11 08 Fax +45 70 20 11 09 info.dk@ifm.com www.ifm.com/dk

Austria
ifm electronic gmbh Wienerbergstrae 41 Gebude E 1120 Vienna Tel. +43 / 1 / 617 45 00 Fax +43 / 1 / 617 45 00 10 info.at@ifm.com www.ifm.com/at

Italy Greece
ifm electronic monoprosopi E.P.E. 27, Andrea Papandreou Street 15125 Amaroussi Greece Tel +30 210 61 800 90 Fax +30 210 61 994 00 info.gr@ifm.com www.ifm.com/gr ifm electronic Centro Direzionale Colleoni Palazzo Andromeda 2 Via Paracelo n 18 20041 Agrate Brianza (Milano) Tel. +39 / 039 68 99 982 Fax +39 / 039 68 99 995 info.it@ifm.com www.ifm.com/it

Chile
Electronica Industrial Schdler y Cia. Ltda. Av. Antonio Varas 1871 Providencia 6641545 Santiago Tel. +56 / 2 / 274 74 30 Fax +56 / 2 / 204 93 38 info@schadler.com www.schadler.com

Dominican Republic
WECH AUTOCONTROLES S. A. Ave. Romulo Betancourt 2158 Edificio Wech Urb. Renacimiento Santo Domingo Dominican Republic Tel.: + 1 809-531-0550 Fax: + 1 809-531-9175 wech@verizon.net.do www.wechautocontroles.com .do

Bangladesh
Sensotec Automation Red Crescent Chamber 87, Motijheel Commercial Area Dhaka 1000 Bangladesh Tel. +880 171 546 890 sensotec@agni.com

Honduras
R y D INDUSTRIAL Bo. Paz Barahona 11 Ave. 14 y 15 Calle S.O. #142 San Pedro Sula Telefon:+504 5503703 Telefax:+504 5501108 ramonmorales@sulanet.net

Japan
efector co. ltd. Chiba Higashi Techno Green Park 2-9-20 Okayamadai Togane-shi, Chiba 283-0826 Tel. +81 / 475 50 3003 Fax +81 / 475 50 3013 ifm-j@efector.co.jp www.ifm.com/jp

China
ifm electronic (Shanghai) Co., Ltd Building 15, No 912 Bi Bo Road, Pu Dong District Shanghai 201210, China Tel. +86-21-50278559 Fax +86-21-50278669 Fax +86-21-50800213 info.cn@ifm.com www.ifm.com/cn ifm electronic (HK) Ltd Unit 2106, 21/F, Tower 2, Metroplaza No. 223 Hing Fong Road, Kwai Chung, N.T., Hong Kong. Telefon: +852 3528-0462 Fax: +852 3697-0222 info.hk@ifm.com www.ifm.com/hk ifm electronic (Taiwan) Limited 2C, Bao-Cheng Enterprise Tower, No. 6 Mincyuan Second Road, Cianjhen District, Kaohsiung City, Postal Code 806, Taiwan, R.O.C. Tel.: +886-7-335-7778 Fax: +886-7-335-6878 info.tw@ifm.com www.ifm.com/tw

Belarus
DEPOSIT INVEST Joint-Stock Company Block 2, 27 Zheleznodorovhnaya street 220089 Minsk Republic of Belarus Tel. +375-17-270 75 06 Fax +375-17-270 75 07 george_ozerov@infonet.by

Ecuador
INSELEC CIA. LTDA. Av. de los Arupos E1-202 y Pan. Norte- Km 5 Quito Tel. +593 2 28074- 76 - 78 Fax +593 2 2807475 inselec@inselec.com.ec www.inselec.com.ec

Hungary
ifm electronic kft. Kzp u. 16. II.em. 208. iroda H-9024 Gyr Tel. +36-96 / 518-397 Fax +36-96 / 518-398 info.hu@ifm.com www.ifm.com/hu

Jordan
Al Mashreqan Trading Supplies P.O.Box.851054 11185 Swaifieh Amman - Jordan. Tel. +962 6 581 8841 Fax +962 6 581 8892 info@mashreqan.com

Egypt
Egyptian Establishment for Electromechanical Supplies Mr. Ahmed Gouda 27 Al-Salam Street Al Arezona, Al Haram Road Giza 12111, Cairo Tel. +20 / 2 / 586 49 49 Fax +20 / 2 / 586 49 49 Mobile +20 10 10 61 791 ahgouda@hotmail.com

Belgium and Luxembourg


ifm electronic n.v./s.a. Zuiderlaan 91 1731 Zellik Belgi Tel. +32 2 481 0220 Fax +32 2 463 1795 info.be@ifm.com www.ifm.com/be

India
ifm electronic India Pvt. Ltd. Plot No. P-39/1 MIDC Gokul Shirgaon Kolhapur 416234 Maharashtra State, India Tel. +91 / 231 / 267 27 70 Fax +91 / 231 / 267 23 88 info@ifm-electronic.in www.ifm.com/in

Korea
ifm electronic Ltd. 2F Hyundai Liberty House #201 Hannam-Dong 258, Yongsan-Gu, Seoul, Korea Tel +82 2-790-5610 Fax +82 2-790-5613 info.kr@ifm.com www.ifm.com/kr

Bolivia
BAVARIA S.R.L. lvaro Baptista Vargas Zona Morocollo, Urb. Santos Pariamo C. Mario Diaz de medina (26-A), Nr. 32 La Paz - Bolivia Tel.: 00-591-2-277 13 78 Mobile: 00-591-720-47 442 alvarobaptista@bavaria.bo www.bavaria.bo

Estonia
Pesmel Estonia LTD Segu 4 76505 Saue Estonia Tel.: +372 674 73 30 Fax: +372 674 73 31 pesmel@pesmel.ee www.pesmel.ee

Indonesia
PT Indoserako Sejahtera Jl. P. Jayakarta 121 No. 59 10730 Jakarta Pusat Tel. +62 / 21 6 24 8923 Fax +62 / 21 6 24 8922 iso297@dnet.net.id

Latvia
EC Systems Katlakalna Str. 4A 1073 Riga Latvia Tel.: +371 724 1231 Fax: +371 724 8478 alnis@ecsystems.lv www.ecsystems.lv

Columbia
SENSOMATIC Y CIA LTDA. CALLE 1 C 25a - 50 BOGOTA D.C. COLOMBIA Tel. +57 313 430 2264 and +57 1 407 96 96 info@sensomatic-ltda.com http://www.sensomaticltda.com

Finland
ifm electronic oy Vaakatie 5 00440 Helsinki Tel. +358 / 9 / 751 777 00 Fax +358 / 9 / 751 777 10 info.fi@ifm.com www.ifm.com/fi

www.ifm.com

236

ifm worldwide addresses

Lebanon
Middle East Development Co. SAL (MEDEVCO) Medevco Building Jeita Main Road Jeita - Kesrouan Lebanon Mail address : P.O.Box 67 Jounieh Lebanon Tel + 961-9-233550 Fax + 961-9-233554 info@medevco-lebanon.com

Nigeria
Automated Process Ltd 3rd Floor, 32 Lagos Abeokuta Expressway Near Cement Bus Stop Dopemu, Agege Lagos State, Nigeria Tel. + 234 / 01 / 4729 967 Fax + 234 /01 / 4925 865 sales@automated-process.com www.automated-process.com

Portugal
ifm electronic Sucursal em Portugal Avenida da Republica 2503 4430-208 Vila Nova de Gaia Tel. +351 / 22 / 37 17 108 Fax +351 / 22 / 37 17 110 info.pt@ifm.com www.ifm.com/pt

Spain
ifm electronic s.l. Edificio Prima Muntadas A Parc Mas Blau C/Bergued 1 08820 El Prat de Llobregat Tel. +34 / 93 / 479 30 80 Fax +34 / 93 / 479 30 86 info.es@ifm.com www.ifm.com/es

United Arab Emirates


Noor Al-Shomoe Electrical Equipments Est. P.O.Box. 64052 Unit no. 36 Reef Real Estate Jebel Ali Industrial Area no. 3 Dubai United Arab Emirates Tel.. + 971 4 880 3838 Fax.+ 971 4 880 3883 Mobile: + 971 505084834 alshomoe@emirates.net.ae www.nooralshomoe.com United Arab Emirates Abu DhabiAl Injazat Technical Trading Services P.O. Box 42895 Abu Dhabi United Arab Emirates Tel. +971 2 622 6030 Fax +971 2 622 3050 kamran@injazat.ae

Romania
ifm electronic s.r.l. Str. Cristian Nr. 5 550073 Sibiu Tel.: 0040 269 224550 Fax: 0040 269 224766 info.ro@ifm.com

Sweden
ifm electronic ab Hallavgen 10 512 60 verlida Office Gothenburg: Drakegatan 6 41250 Gothenburg Tel. +46 / 325 / 66 15 00 Tel. +46 / 325 / 66 15 50 Fax +46 / 325 / 66 15 90 info.se@ifm.com www.ifm.com/se

Norway
Siv.Ing. J.F.Knudtzen AS Billingstadsletta 97 1396 Billingstad Postboks 160 1378 Nesbru Tel. +47 / 66 98 33 50 Fax +47 / 66 98 09 55 firmapost@jfknudtzen.no www.jfknudtzen.no

Lithuania
Elinta UAB Terminalo g. 3, Biruliki k., Karmlavos sen. LT-54469 Kauno raj. (Kauno LEZ) Lithuania Tel.: +370 37 351 999 Fax: +370 37 452 780 sales@elinta.lt www.elintosprekyba.lt

Russia
ifm electronic Ibragimova, 31, k.50 office 607 105318 Moscow Tel.: +7 (495) 921-44-14 Fax: +7 (495) 651-82-97 info.ru@ifm.com www.ifm.com/ru

Oman
Technical Engineering Company LLC. P.O.Box. 59 Madinat Al Sultan Qaboos Postal Code 115 Sultanate of Oman Tel + 968 24503593 Fax + 968 24503573 tecoman@omantel.net.om

Switzerland
ifm electronic ag Altgraben 27 4624 Hrkingen Tel. +41 / 62 / 388 80 30 Fax +41 / 62 / 388 80 39 info.ch@ifm.com www.ifm.com/ch

United Kingdom
ifm electronic Ltd. efector House Kingsway Business Park Oldfield Road Hampton Middlesex TW12 2HD Tel. +44 / 20 / 8213 0000 Fax +44 / 20 / 8213 0001 enquiry_gb@ifm.com www.ifm.com/uk

Malaysia
ifm electronic Pte. Ltd Malaysian Branch Office No. 2-4-2, Fourth Floor Tower 2 @ PFCC, Jalan Puteri 1/2, Bandar Puteri Puchong, 47100 Puchong, Selangor. Tel. +60 / 3 / 8063 9522 Fax +60 / 3 / 8063 9524 sales_my@ifm.com ifm electronic Asia Regional Office No. 21, Jalan Kemunting, Taman Kebun The 80250 Johor Bahru Johor, West Malaysia Tel. +60 / 7 / 332 5022 Fax +60 / 7 / 332 1577 sales_my@ifm.com

Saudi Arabia
Noor Al-Shomoe for Electric & Maintenance King Khalid Street, Cross 5 P.O. Box 2571 Al-Khobar 31952 Kingdom of Saudi Arabia Tel. +9 663 864 49 58 Fax +9 663 894 63 41 h.o.info@nooralshomoe.com

Syria
I.E.C. Industrial Engineering Center P.O. Box 15 Sehnaya, Damascus Syria Tel. + 963 11 532 13 19 Fax. + 963 11 442 12 27 info@iec-automation.com

Pakistan
AB Automation Shop No.2. Rubab Chamber M.A. Jinnah Road Off Sarai Road Karachi Tel. +92 / 21 / 2412 278 Fax +92 / 21 / 2422 277 abauto@cyber.net.pk

USA
efector inc. 805 Springdale Drive Exton, PA 19341 Tel. +1 / 610 524 2000 Fax +1 / 610 524 2010 info@ifmefector.com www.ifmefector.com

Singapore
ifm electronic Pte. Ltd. 25, Intern. Business Park #03-104 German Center 609 916 Singapore Tel. +65 / 6 / 5 62 86 61 Fax +65 / 6 / 5 62 86 60 sales_sg@ifm.com www.ifm.com/sg

Thailand
Sang Chai Meter Co., Ltd. 694/16-19 Phaholyothin Road Samsen Nai, Phayathai Bangkok 10400 Tel. +66 / 2 / 616 8051 Fax +66 / 2 / 616 8050 scmth@ksc.th.com

Peru
dekatec s.a.c. Los Calderos 188 Urb. Vulcano, Ate Lima / Peru Tel. +511 / 348 0293 Tel. +511 / 348 0458 Tel. +511 / 348 2269 Fax +511 / 349 0110 dkleffmann@dekatec.com.pe www.dekatec.com.pe

Venezuela
Petrobornas, C.A. C.C. Los Pinos - Local E Av. Principal de la UD 304 (8015) - Puerto Ordaz - Edo. Bolivar Venezuela Tel. +58 286 994 3406 Tel. +58 416 686 5036 Fax +58 286 994 5249 info@petrobornas.net www.petrobornas.net

Mexico
ifm efector S. de R.L. de C.V. Anillo Perifrico, 1816-1 Col. Hacienda San Jernimo Monterrey, N.L. Mexico 64630 Tel. +52-81-8040-3535 Fax +52-81-8040-2343 www.ifmefector.mx

Slovakia
ifm electronic spol. s.r.o. Rybnicna 40 831 06 Bratislava Tel. +421 / 2 / 44 87 23 29 Fax +421 / 2 / 44 64 60 42 info.sk@ifm.com www.ifm.com/sk

Turkey
ifm electronic Elektrikli ve Elektronik Aletler th.hr.Paz.Tic.Ltd.ti. Merkez Mah. Nadide Sok. Anttepe Sitesi No:28 34381 ili / stanbul Tel. +90 / 212 / 210 5080 Fax +90 / 212 / 221 7159 info.tr@ifm.com www.ifm.com/tr

Philippines
Gram Industrial, Inc. Unit 410 Common Goal Tower Finance cor. Industry St., Madrigal Business Park, Ayala Alabang, Muntinlupa City 1770 Philipines Tel. (+63) 2 850-2218 Fax (+63) 2 850-8496 efector@gram.com.ph

Vietnam
Thien Viet Electrical Service and Trading Co., Ltd. 784 Dien Bien Phu Str. Ward 11, Dist. 10 Ho-Chi-Minh-City, Viet Nam Tel. +84 / 8 / 830 9916 Fax +84 / 8 / 830 9915 thivicoltd@hcm.vnn.vn

Netherlands
ifm electronic b.v. Deventerweg 1 E 3843 GA Harderwijk Tel. +31 / 341 438 438 Fax +31 / 341 438 430 info.nl@ifm.com www.ifm.com/nl

South Africa
ifm electronic (pty) Ltd Shorrok House Route 21 Corporate Park Nellmapius Drive, Irene Ext. 30, Centurion 0157, Pretoria Postnet Suite 279 Private bag X8 Elardus Park 0047 Tel. +27 (0) 861 IFM RSA / 436 772 Fax +27(0)12 450 0322 info.za@ifm.com www.ifm.com/za

Ukraina
ifm electronic Mariny Raskovoj 11 02660 Kiev Ukraine Tel. +380 44 501 8543 Fax +380 44 501 8543 info.ua@ifm.com www.ifm.com/ua

New Zealand
ifm efector pty ltd. Unit B, 20 Cain Road Penrose, Auckland Tel. +64 / 95 79 69 91 Fax +64 / 95 79 92 82 sales.nz@ifm.com www.ifm.com/nz

Poland
ifm electronic Sp.z o.o. ul. Kosciuszki 175 PL 40-524 Katowice Tel. +48 / 32 / 60 87 454 Fax +48 / 32 / 60 87 455 info.pl@ifm.com www.ifm.com/pl

www.ifm.com

237

www.ifm.com

Vous aimerez peut-être aussi