Programmable Thermostat
System Types
Gas, oil, or electric heat with air conditioning Warm air, hot water, highefficiency furnaces, heat pumps, steam, gravity
Heat only two-wire systems, three-wire zone valves (Series 20), and normally open zone valves Heat only with fan Cool only 750 mV heating systems
Need Help?
For assistance with this product please visit http://customer.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502
U.S. Registered Trademark. Patents pending. Copyright 2009 Honeywell International Inc. All rights reserved.
69-1920EFS-01
Installation Guide
Wallplate installation
1. Separate wallplate from thermostat. 2. Mount wallplate as shown below.
Remove battery holder. Pull here to remove wallplate from new thermostat. It's easier to grasp the wallplate and remove it after completely removing the battery holder. Insert reference card after wallplate is mounted (see instructions, below).
MCR29434 M29433
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wire hole
Mounting screws
Wall anchors
ENGLISH
Wallplate
MCR29435
CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal. 69-1920EFS01 2
Power options
Keep wires in this shaded area Remove factoryinstalled jumper only for twotransformer systems.
Wiring
Terminal designations
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted. Conventional Terminals:
Rc R W W2 Y Y2 G C 24VAC power from cooling transformer 24VAC power from heating transformer Heat relay (stage 1) Heat relay (stage 2) Compressor contactor (stage 1) Compressor contactor (stage 2) Fan relay 24VAC common. For 2 transformer systems, use common wire from cooling transformer. G E L C
ENGLISH
Emergency heat relay* Sends output when set to Em. Heat 24VAC common
TH6110D
G W C Y R Rc
TH6110D
G C Y R Rc
TH6220D
Y2 W2 G W C Y R Rc
TH6220D
L E Aux G C Y R Rc
TH6320U
Y2 W2 G W C Y R Rc
MCR29437
TH6320U
L Y2 Aux G E C Y R Rc
MCR29438
69-1920EFS01
Installation Guide
Wiring
Wiring guide conventional systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted. 1H/1C System
(1 transformer) G W C Y R Rc MCR29439 Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor C 24VAC common [3] W Heat relay G Fan relay
Power [1] [R+Rc joined by jumper] 24VAC common [3] Heat relay Fan relay
G W C
MCR29444
R Rc
Heat-only System
Rc R C W
W C Power [1] [R+Rc joined by jumper] 24VAC common [3] Heat relay
MCR29440
Cool-only System
R Rc
Rc R Y C G
Power [1] G [R+Rc joined by jumper] Compressor contactor 24VAC common [3] Fan relay
C Y R Rc
MCR29445
Heat-only System
(Series 20) [5] W C Y R Rc MCR29441 Rc [R+Rc joined by jumper] R Series 20 valve terminal R [1] Y Series 20 valve terminal W C 24VAC common [3] W Series 20 valve terminal B
2H/2C System
Heat-only System
C Y R Rc (normally open zone valve) [5] MCR29442 Rc [R+Rc joined by jumper] R Power [1] Y Normally open zone valve C 24VAC common [3]
(1 transformer) [6] Y2 W2 G W C Y R Rc Rc Power [1] MCR29446 R [R+Rc joined by jumper] Y Compressor contactor (stage 1) C 24VAC common [3] W Heat relay (stage 1) G Fan relay W2 Heat relay (stage 2) Y2 Compressor contactor (stage 2)
2H/2C System
1H/1C System
G W C Y R Rc (2 transformers) M29443 Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] Y Compressor contactor C 24VAC common [3, 4] W Heat relay G Fan relay
Y2 W2 G W C Y R Rc (2 transformers) [6] M29447 Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] Y Compressor contactor (stage 1) C 24VAC common [3, 4] W Heat relay (stage 1) G Fan relay W2 Heat relay (stage 2) Y2 Compressor contactor (stage 2)
ENGLISH
NOTES
Wire specifications: Use 18- to 22-gauge thermostat wire. Shielded cable is not required. [1] Power supply. Provide disconnect means and overload protection as required. [2] Remove jumper for 2-transformer systems. [3] Optional 24VAC common connection. [4] Common connection must come from cooling transformer. [5] In Installer Setup, set system type to Heat Only. [6] In Installer Setup, set system type to 2Heat/2Cool Conventional.
69-1920EFS01
Wiring
Wiring guide heat pump systems
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted. 1H/1C Heat Pump System
Rc R Y C O/B G Power [1] [R+Rc joined by jumper] Compressor contactor 24VAC common [3] Changeover valve [7] Fan relay
C Y R Rc MCR29448
L E Aux G C Y R Rc (TH6220D only) [8] MCR29449 Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor C 24VAC common [3] O/B Changeover valve [7] G Fan relay Aux Auxiliary heat relay [12] E Emergency heat relay [12] L Sends output when set to Em. Heat [11]
L Y2 G C Y R Rc (TH6320U only) [9] MCR29451 Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor (stage 1) C 24 VAC common [3] O/B Changeover valve [7] G Fan relay Y2 Compressor contactor (stage 2) L Sends output when set to Em. Heat [11]
(TH6320U only) [8] L Aux G C Y R Rc E MCR29450 Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor C 24VAC common [3] O/B Changeover valve [7] G Fan relay Aux/E Auxiliary/Emergency heat relay L Sends output when set to Em. Heat [11]
L Y2 Aux G C Y R Rc (TH6320U only) [10] E MCR29452 Rc Power [1] R [R+Rc joined by jumper] Y Compressor contactor (stage 1) C 24VAC common [3] O/B Changeover valve [7] G Fan relay Aux/E Auxiliary/Emergency heat relay Y2 Compressor contactor (stage 2) L Sends output when set to Em. Heat [11]
ENGLISH
Thermostat mounting
Align the 4 tabs on the wallplate with slots on the back of the thermostat, then push gently until the thermostat snaps in place.
Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation.
MCR29453
69-1920EFS01
Installation Guide
Installer setup
Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired.
Function number Setting
1
Done Next
0
MCR29454
To begin, press and hold the s and FAN buttons until the display changes.
Press s or t to change settings. Press NEXT to advance to the next function. Press DONE to exit and save settings.
Setup function
1 System type
2 3
0 1 0 1
ENGLISH
Stage 1 heat cycle 5 rate (CPH: cycles/hour)* 1 3 9 Stage 2 heat cycle rate/Auxiliary heat cycle rate (CPH)* Auxiliary heat cycle rate (CPH)* Only TH6320U for 3H/2C Heat Pumps 5 1 3 9 5 1 3 9
69-1920EFS01
Installer setup
Setup function
9 Stage 1 compressor cycle rate (CPH)
10 Stage 2 compressor cycle rate (CPH) 12 Manual/Auto changeover 13 Adaptive Intelligent Recovery 14 Temperature display 15 Compressor protection 16 Schedule format 27 Heat temperature range stops 28 Cool temperature range stops
10
To begin, press and hold the s and t buttons until the display changes.
0
MCR29455
Press s / t to turn system on/off. Press NEXT to advance to next test. Press DONE to terminate system test.
ENGLISH
System test
10 Heating system
System status
0 1 2 3 Heat and fan turn off. Stage 1 heat turns on. Fan turns on if Setup Function 1 is set to 1, 5, 9 or 10 OR Setup Function 3 is set to 1 **See page 6 Stage 2 heat turns on Stage 3 heat turns on - TH6320U only Heat and fan turn off Heat and fan turn on Stage 2 heat turns on (auxiliary heat) - TH6220D only Compressor and fan turn off Compressor and fan turn on Stage 2 compressor turns on Fan turns off Fan turns on
0 1 2 0 1 2 0 1
40 Fan system
CAUTION: Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. 7 69-1920EFS01
Installation Guide
Special functions
Auto Changeover (Setup Function 12): When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. The thermostat will automatically adjust heat and cool settings to maintain a 3-degree separation (fixed). Note: If you select Auto Changeover Only, the System Setting on the thermostat will stay locked in the Auto position, preventing the user from changing it to Em Heat, Heat, Cool or Off. Adaptive Intelligent Recovery (Setup Function 13): Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the scheduled time. Compressor Protection (Setup Function 15): Forces the compressor to wait a few minutes before restarting, to prevent damage. During the wait time, the message Cool On or Heat On (heat pumps only) will flash on the display.
Specifications
Temperature Ranges Heat: 40 to 90F (4.5 to 32C) Cool: 50 to 99F (10 to 37C) Operating Ambient Temperature 32 to 120F (0 to 48.9C) Shipping Temperature -20 to 120F (-28.9 to 48.9C) Operating Relative Humidity 5% to 90% (non-condensing) Physical Dimensions 3-9/16" H x 5-13/16" W x 1-1/2" D 91 mm H x 147 mm W x 38 mm D Electrical Ratings Terminal W Heating (Powerpile) W2 (Aux) Heating Y Cooling Y2 Cooling G Fan O/B Changeover E Emergency heat L Output Voltage (50/60Hz) 20-30 Vac 750 mV DC 20-30 Vac 20-30 Vac 20-30 Vac 20-30 Vac 20-30 Vac 20-30 Vac 20-30 Vac Running Current 0.02-1.0 A 100 mA DC 0.02-0.5 A 0.02-1.0 A 0.02-1.0 A 0.02-0.5 A 0.02-0.5 A 0.02-1.0 A 0.02-0.5 A
Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limite 35 Dynamic Drive Toronto, Ontario M1V 4Z9
http://customer.honeywell.com
Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. U.S. Registered Trademark. 2009 Honeywell International Inc. 69-1920EFS01 M.S. 05-09
Guide dinstallation
Thermostat programmable
Types de systme
Chauffage au gaz naturel, au mazout ou llectricit avec climatiseur Fournaises grand rendement air chaud ou eau chaude ; thermopompes, systmes la vapeur ou gravitaires
Chauffage seulement systmes deux fils, soupapes de zone trois fils (Srie 20) soupapes de zones normalement ouvertes Chauffage seulement avec soufflante Climatisation seulement Systmes de chauffage de 750 mV
Besoin daide?
Pour obtenir de lassistance au sujet de ce produit, consulter le http://customer.honeywell.com ou tlphoner sans frais au Centre de service la clientle de Honeywell au 1 800 468-1502
Marque dpose aux .-U. Brevets en instance. 2009 Honeywell International Inc. Tous droits rservs.
Guide dinstallation
Insrer la carte de rfrence aprs avoir install la plaque murale (voir les instructions ci-dessous).
MCR29434 M29433
Trou du fil
Vis de montage
Ancrages muraux
Plaque murale
FRANAIS
MCR29435
MISE EN GARDE : RISQUE DE CHOC LECTRIQUE Peut causer un choc lectrique ou endommager lquipement. Couper lalimentation avant de commencer linstallation. REMARQUE PROPOS DU MERCURE : Si ce produit sert remplacer une commande qui contient du mercure dans un tube scell, ne pas jeter la vieille commande aux ordures. Consulter ladministration locale de gestion des dchets pour connatre les instructions relatives au recyclage et llimination. 69-1920EFS01 2
Options dalimentation
Garder les fils dans cette zone ombrage. Enlever le cavalier install en usine uniquement pour les systmes deux transformateurs.
Insrer les piles pour lalimentation primaire ou de secours. Brancher C pour lalimentation CA primaire (facultatif si des piles sont installes).
MCR29436
Cblage
Dsignation des bornes
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications. Bornes traditionnelles :
Rc R W W2 Y Y2 G C Alimentation de 24 V CA pour le transformateur de climatisation Alimentation de 24 V CA pour le transformateur de chauffage Relais de chauffage (stade 1) Relais de chauffage (stade 2) Contacteur du compresseur (stade 1) Contacteur du compresseur (stade 2) Relais de la soufflante Neutre 24 V CA. Pour les systmes 2 transformateurs, utiliser le neutre pour le transformateur de climatisation
Bornes de thermopompe :
Rc R Alimentation de 24 V CA pour le transformateur de climatisation Alimentation de 24 V CA pour le transformateur de chauffage Contacteur de compresseur (stade 1) Contacteur du compresseur (stade 2) -TH6320U seulement Relais de la soufflante Relais de chauffage durgence* Envoie le signal de sortie lorsque rgl Em. Chauffage Neutre 24 V CA
TH6110D
G W C Y R Rc
TH6110D
FRANAIS
C Y R Rc
TH6220D
Y2 W2 G W C Y R Rc
TH6220D
L E Aux G C Y R Rc
TH6320U
Y2 W2 G W C Y R Rc
MCR29437
TH6320U
L Y2 Aux G E C Y R Rc
MCR29438
69-1920EFS01
Guide dinstallation
Cblage
Guide de cblage systmes traditionnels
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications. Systme 1C/1C (1 transformateur) G W C Y R Rc Rc Alimentation [1] MCR29439 R [R+Rc reli par le cavalier] Y Contacteur de compresseur C Neutre 24 V CA [3] W Relais de chauffage G Relais de la soufflante Systme de chauffage seulement W C Rc Alimentation [1] R [R+Rc reli par le cavalier] C Neutre 24 V CA [3] W Relais de chauffage Systme de chauffage seulement G W C avec soufflante Rc Alimentation [1] R [R+Rc relis par le cavalier] C Neutre 24 V CA [3] W Relais de chauffage G Relais de la soufflante
MCR29444
R Rc
MCR29440
R Rc
Systme de climatisation seulement G C Y R Rc MCR29445 Rc Alimentation [1] R [R+Rc relis par le cavalier] Y Contacteur de compresseur C Neutre 24 V CA [3] G Relais de la soufflante Systme 2C/2C (1 transformateur) [6] Y2 W2 G W C Y R Rc Rc Alimentation [1] MCR29446 R [R+Rc relis par le cavalier] Y Contacteur du compresseur (stade 1) C Neutre 24 V CA [3] W Relais de chauffage (stade 1) G Relais de la soufflante W2 Relais de chauffage (stade 2) Y2 Contacteur du compresseur (stade 2) Systme 2C/2C (2 transformateurs) [6] Y2 W2 G W C Y R Rc Rc Alimentation (transformateur de M29447 climatisation) [1, 2] R Alimentation (transformateur de chauffage) [1, 2] Y Contacteur du compresseur (stade 1) C Neutre 24 V CA [3, 4] W Relais de chauffage (stade 1) G Relais de la soufflante W2 Relais de chauffage (stade 2) Y2 Contacteur du compresseur (stade 2) Voir [Remarques] ci-dessous [7] Lors de la configuration, rgler le type de systme O ou B. [8] Lors de la configuration, rgler le type de systme Thermopompe 2 chauffages/1 climatisation (2Heat/1Cool Heat Pump). [9] Lors de la configuration, rgler le type de systme Thermopompe 2 chauffages/2 climatisation (2Heat/2Cool Heat Pump). [10] Lors de la configuration, rgler le type de systme Thermopompe 3 chauffages/2 climatisation (3Heat/2Cool Heat Pump). [11] La borne L envoie un signal continu lorsque le thermostat est rgl Em. Chauffage Brancher aux panneaux de zones Honeywell pour commuter le panneau au chauffage durgence. [12] Installer le cavalier de champ entre Aux et E sil ny a pas de relais de chauffage durgence. 4
Systme de chauffage W C Y R Rc seulement (Srie 20) [5] MCR29441 Rc [R+Rc relis par le cavalier] R Borne de soupape R de Srie 20 [1] Y Borne de soupape W de Srie 20 C Neutre 24 V CA [3] W Borne de soupape B de Srie 20 Systme de chauffage seulement C Y R Rc (soupape de zone normalement ouverte) [5] MCR29442 Rc [R+Rc relis par le cavalier] R Alimentation [1] Y Soupape de zone normalement ouverte C Neutre 24 V CA [3] Systme 1C/1C (2 transformateurs) G W C Y R Rc M29443 Rc Alimentation (transformateur de climatisation) [1, 2] R Alimentation (transformateur de chauffage) [1, 2] Y Contacteur de compresseur C Neutre 24 V CA [3, 4] W Relais de chauffage G Relais de la soufflante REMARQUES Spcifications des fils : Utiliser du fil pour thermostat de calibre 18 22. Il nest pas ncessaire dutiliser des cbles blinds. [1] Alimentation. Procure un moyen de dbrancher et une protection contre la surcharge au besoin. [2] Retirer le cavalier pour les systmes 2 transformateurs. [3] Connexion facultative au neutre 24 V CA. [4] La connexion du neutre doit venir du transformateur de climatisation. [5] Lors de la configuration, rgler le type de systme Chauffage seulement (Heat Only). [6] Lors de la configuration, rgler le type de systme Traditionnel 2 chauffages/2 climatisations (2Heat/2Cool Conventional).
FRANAIS
69-1920EFS01
Cblage
Guide de cblage systmes de thermopompes
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications. Systme de thermopompe 1C/1F G Rc Alimentation [1] R [R+Rc relis par le cavalier] Y Contacteur de compresseur C Neutre 24 V CA [3] O/B Robinet de substitution [7] G Relais de la soufflante Systme de thermopompe 2C/1F Rc R Y C O/B G Aux E L Systme de thermopompe 2C/2F Rc R Y C O/B G Y2 L
C Y R Rc MCR29449
C Y R Rc MCR29448
L Y2
L E Aux G
Alimentation [1] [R+Rc relis par le cavalier] Contacteur du compresseur (stade 1) Neutre 24 V CA [3] Robinet de substitution [7] Relais de la soufflante Contacteur du compresseur (stade 2) Envoie le signal de sortie lorsque rgl Em. Chauffage [11]
C Y R Rc MCR29451
Alimentation [1] [R+Rc relis par le cavalier] Contacteur de compresseur Neutre 24 V CA [3] Robinet de substitution [7] Relais de la soufflante Relais auxiliaire de chauffage [12] Relais de chauffage durgence [12] Envoie le signal de sortie lorsque rgl Em. Chauffage [11]
Alimentation [1] [R+Rc relis par le cavalier] Contacteur de compresseur Neutre 24 V CA [3] Robinet de substitution [7] Relais de la soufflante Relais auxiliaire de chauffage/ de chauffage durgence Envoie le signal de sortie lorsque rgl Em. Chauffage [11]
Aux G E
C Y R Rc MCR29450
MCR29452 Alimentation [1] [R+Rc relis par le cavalier] Contacteur du compresseur (stade 1) Neutre 24 V CA [3] Robinet de substitution [7] Relais de la soufflante Relais auxiliaire de chauffage/ de chauffage durgence Contacteur du compresseur (stade 2) Envoie le signal de sortie lorsque rgl Em. Chauffage [11]
L Y2 Aux G E
C Y
R Rc
Installation du thermostat
Placer les fentes larrire du thermostat vis vis des 4 languettes correspondantes de la plaque murale, puis appuyer doucement jusqu ce quelles sengagent une dans lautre.
Repousser tous les fils excdents dans le mur. Remplir lorifice dans le mur avec de lisolation non inflammable.
MCR29453
FRANAIS
69-1920EFS01
Guide dinstallation
Configuration du systme
Suivez la procdure ci-dessous pour configurer le thermostat pour correspondre au systme de chauffage et de climatisation install, et pour paramtrer les fonctions tel que voulu.
Numro de fonction Rglage
1
Done Next
0
MCR29454
Appuyer sur s ou t pour modifier les rglages. Pour commencer, enfoncer et tenir les boutons Appuyer sur NEXT pour passer la fonction suivante. Appuyer sur DONE pour quitter s et FAN jusqu ce que laffichage change. la configuration et enregistrer les rglages.
Fonction de configuration
1 Type de systme
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications.
Robinet de substitution (Borne O/B) Commande de soufflante (chauffage) Rythme de cycle de chauffage de stade 1 (CPH: cycles par heure)*
0 1 0 1 5 1 3
9 Rythme de cycle de chauff- 5 age de stade 2/rythme de cycle de chauffage auxiliaire 1 (CPH)* 3 9 Rythme de cycle de chauff- 5 age auxiliaire (CPH)* Seulement le TH6320U 1 pour les thermopompes 3 3C/2F 9 Rythme de cycle de chauff- 9 1 age durgence (CPH)* 3 5
FRANAIS
69-1920EFS01
Configuration du systme
Fonction de configuration
9 10 Rythme de cycle de compresseur de stade 1 (CPH) Rythme de cycle de compresseur de stade 2 (CPH) Substitution manuelle/ automatique
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications.
12
0 1 2
13
14 15
MC
1 0
0 1 5
16
27 28
Format de lhoraire
Crans de la fourchette de temprature de chauffage Crans de la fourchette de temprature de climatisation
0 1
90 50
5/2 (programmation de jours de semaine et de week-ends) 5/1/1 (programmation des jours de semaine, du samedi et du dimanche)
Rglage maximum de temprature de chauffage est 90 F (32 C) [Autres options : 40 F 89 F (4.5 C 31.5 C)] Rglage minimum de temprature de climatisation est 50 F (10 C) [Autres options : 51 F 99 F (10.5 C 37 C)]
10
Pour commencer, enfoncer et tenir les touches s et t jusqu ce que laffichage change.
0
MCR29455
Appuyer sur s / t pour activer ou dsactiver le systme. Appuyer sur NEXT pour passer lessai suivant. Appuyer sur DONE pour terminer lessai du systme.
Essai du systme
10 Systme de chauffage
tat du systme
0 1 2 3 Arrter le chauffage et la soufflante. Activation du chauffage de stade 1. La soufflante entre en fonction si la fonction de configuraton 1 est rgle 1 ou 5 OU si la fonction de configuration 3 est rgle 1 **Voir page 6. Activation du chauffage de stade 2. Activation du chauffage de stade 3 - TH6320U seulement. Arrter le chauffage et la soufflante. Mise en fonction du chauffage et de la soufflante. Activation du chauffage de stade 2 (chauffage auxiliaire) - TH6220D seulement Arrter le chauffage et la soufflante. Mise en fonction du compresseur et de la soufflante. Activation du compresseur de stade 2. Dsactivation de la soufflante. Activation de la soufflante.
Les zones ombrages ci-dessous sappliquent seulement au TH6320U/TH6220D ou selon les indications.
FRANAIS
20
Systme de chauffagedurgence
0 1 2
30
40
MISE EN GARDE : La protection du compresseur est contourne lors de lessai. Pour prvenir les dommages lquipement, viter dactiver et dsactiver le compresseur intervalles rapides. 7 69-1920EFS01
Guide dinstallation
Fonctions spciales
Substitution automatique (Fonction de configuration 12) : Lorsque rgl Auto, le thermostat slectionne automatiquement le chauffage ou la climatisation selon la temprature intrieure. Le thermostat ajuste automatiquement les rglages pour maintenir un cart de 3 degrs (fixe). Remarque : Si vous slectionnez Substitution automatique seulement, le rglage du systme dans le thermostat demeurera verrouill la position Auto, empchant lutilisateur de le changer Em Heat, Heat, Cool ou Off. Adaptative Intelligent Recovery (Fonction de configuration 13) : Permet au thermostat dapprendre combien de temps la fournaise ou le climatiseur prend pour atteindre la temprature programme afin que la temprature atteigne la temprature voulue au moment voulu.
MC
Protection du compresseur (Fonction de configuration 15) : Force le compresseur attendre quelques minutes avant de redmarrer pour prvenir les dommages. Durant la priode dattente, le message Cool On ou Heat On (thermopompes seulement) clignotera sur laffichage.
Spcifications
Fourchettes de temprature Chauffage : 40 90 F (4,5 32 C) Climatisation : 50 99 F (10 37 C) Temprature ambiante de fonctionnement 32 120 F (0 48,9 C) Temprature dexpdition -20 120 F (-28,9 48,9 C) Humidit relative de fonctionnement 5 % 90 % (sans condensation) Dimensions 3-9/16 po H x 5-13/16 po L x 1-1/2 po P 91 mm H x 147 mm L x 38 mm P Cote lectrique Borne W Chauffage (Pile) W2 (Aux) Chauffage Y Climatisation Y2 Climatisation G Soufflante O/B Substitution L Sortie Tension (50/60 Hz) 20-30 V CA 750 mV CC 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA Courant de fonctionnement 0,02-1,0 A 100 mA CC 0,02-0,5 A 0,02-1,0 A 0,02-1,0 A 0,02-0,5 A 0,02-0,5 A 0,02-1,0 A 0,02-0,5 A
Solutions dautomatisation et de contrle Honeywell International Inc 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limite 35, promenade Dynamic Toronto (Ontario) M1V 4Z9
http://customer.honeywell.com
Imprim aux .-U. sur du papier recycl contenant au moins 10 % de fibres de papier recycles aprs consommation. Marque dpose aux .-U. 2009 Honeywell International Inc. 69-1920EFS01 M.S. 05-09
Gua de instalacin
Termostato programable
Tipos de sistemas
Sistema de calefaccin de gas, de aceite o elctrico con aire acondicionado Calefaccin de aire, agua caliente, sistemas de calefaccin de alta efectividad, bombas de calor, vapor, gravedad
Slo calor: sistemas de 2 cables, vlvulas de separacin de tres cables (serie 20) y vlvulas de separacin normalmente abiertas Slo calor con ventilador Slo fro Sistemas de calefaccin de 750 mV
Necesita asistencia?
Para obtener asistencia relacionada con este producto, visite http://customer.honeywell.com o comunquese con el nmero gratuito del servicio de atencin al cliente de Honeywell, llamando al 1-800-468-1502
Marca registrada de los EE. UU. Patentes en trmite.
2009, Honeywell International Inc. Todos los derechos reservados.
Gua de instalacin
Introduzca la tarjeta de referencia luego de montar la placa para pared (lea las instrucciones que aparecen abajo).
MCR29434 M29433
Tornillos de montaje
Anclas de expansin
PRECAUCIN: RIESGO ELCTRICO Puede ocasionar descargas elctricas o daar el equipo. Desconecte la energa elctrica antes de comenzar la instalacin. AVISO SOBRE EL MERCURIO En caso de que este producto reemplace a un control que contenga mercurio en tubo sellado, evite arrojar el viejo control a la basura. Pngase en contacto con la autoridad local para el manejo de desechos a fin de obtener instrucciones sobre el reciclado y la correcta eliminacin de este tipo de desechos. 69-1920EFS01 2
ESPAOL
Cableado
Designacin de terminales
Las reas sombreadas que aparecen abajo slo se utilizan para los modelos TH6320U y TH6220D o segn se indique.
Terminales convencionales:
Rc R W W2 Y Y2 G C 24 V CA desde el transformador del sistema de refrigeracin 24 V CA desde el transformador del sistema de calefaccin Rel de calor (etapa 1) Rel de calor (etapa 2) Interruptor automtico del compresor (etapa 1) Interruptor automtico del compresor (etapa 2) Rel del ventilador 24 V CA. Para los sistemas de 2 transformadores, utilice cables comunes desde el transformador de la refrigeracin.
TH6110D
G W C Y R Rc
TH6110D
G C Y R Rc
TH6220D
Y2 W2 G W C Y R Rc
TH6220D
L E Aux G C Y R Rc
TH6320U
Y2 W2 G W C Y R Rc
MCR29437
TH6320U
L Y2 Aux G E C Y R Rc
MCR29438
ESPAOL
69-1920EFS01
Gua de instalacin
Cableado
Gua de cableado: sistemas convencionales
Las reas sombreadas que aparecen abajo slo se utilizan para las series TH6320U y TH6220D o segn se indique.
Sistema de 1 calentador y 1 refrigerador (1 transformador) G W C Y R Rc Rc Electricidad [1] MCR29439 R [R+Rc unidos por un puente] Y Interruptor automtico del compresor C 24 V CA [3] W Rel de calor G Rel del ventilador Sistema de calefaccin nicamente Rc R C W Electricidad [1] [R+Rc unidos por un puente] 24 V CA comn [3] Rel de calor Sistema de calefaccin con ventilador Rc R C W G
G W C Electricidad [1] [R+Rc unidos por un puente] 24 V CA [3] Rel de calor Rel del ventilador
MCR29444
R Rc
W C
MCR29440
R Rc
G C Y R Rc Electricidad [1] MCR29445 [R+Rc unidos por un puente] Interruptor automtico del compresor 24 V CA [3] Rel del ventilador
W C Y R Rc [R+Rc unidos por un puente] MCR29441 Terminal R de la vlvula de la serie 20 [1] Terminal W de la vlvula de la serie 20 24 V CA [3] Terminal B de la vlvula de la serie 20
R Rc Electricidad [1] Y2 W2 G W C YMCR29446 [R+Rc unidos por un puente] Interruptor automtico del compresor (etapa 1) 24 V CA [3] Rel de calor (etapa 1) Rel del ventilador Rel de calor (etapa 2) Interruptor automtico del compresor (etapa 2)
C Y R Rc MCR29442 [R+Rc unidos por un puente] Electricidad [1] Vlvula de separacin normalmente abierta 24 V CA [3]
Y2 W2 G W C Y R Rc
M29447
G W C Y R Rc
Electricidad (transformador de refrigeracin) [1, 2] Electricidad (transformador de calefaccin) [1, 2] Interruptor automtico del compresor 24 V CA [3, 4] Rel de calor Rel del ventilador
M29443
Electricidad (transformador de refrigeracin) [1, 2] Electricidad (transformador de calefaccin) [1, 2] Interruptor automtico del compresor (etapa 1) 24 V CA [3, 4] Rel de calor (etapa 1) Rel del ventilador Rel de calor (etapa 2) Interruptor automtico del compresor (etapa 2)
Vea las [notas] abajo [7] Durante la configuracin de instalacin, coloque la vlvula de conversin en la posicin O o B. [8] Durante la configuracin de instalacin, coloque el tipo de sistema en Bomba de calor de 2 calentadores y 1 refrigerador. [9] Durante la configuracin de instalacin, coloque el tipo de sistema en Bomba de calor de 2 calentadores y 2 refrigeradores. [10] Durante la configuracin de instalacin, coloque el tipo de sistema en Bomba de calor de 3 calentadores y 2 refrigeradores. [11] El terminal L enva un flujo continuo de aire caliente cuando el termostato est en la posicin Em. Heat (calor de emeregencia). Conctelo a los paneles de separacin de Honeywell para cambiar a Em. Heat. [12] Coloque el puente de campo entre Aux y E si no existe un rel de emergencia de calor.
NOTAS
Especificaciones del cable: Use cable para termostato de calibre 18 a 22. No se requiere cable blindado. [1] Fuente de alimentacin. Proporciona el medio de desconexin y la proteccin contra sobrecargas requeridos. [2] Para sistemas de 2 transformadores, quite el puente. [3] Conexin comn de 24 V CA opcional. [4] La conexin comn debe provenir del transformador de refrigeracin. [5] Durante la configuracin de instalacin, coloque el tipo de sistema en Slo calor. [6] Durante la configuracin de instalacin, coloque el tipo de sistema en Convencional de 2 calentadores y 2 refrigeradores.
ESPAOL
69-1920EFS01
Cableado
Gua de cableado: sistemas de bomba de calor
Las reas sombreadas que aparecen abajo slo se utilizan para los modelos TH6320U/ TH6220D o segn se indique.
Sistema de bomba de calor de 1 calentador y 1 refrigerador G C Y R Rc MCR29448 Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automtico del compresor C 24 V CA [3] O/B Vlvula inversora [7] G Rel del ventilador Sistema de bomba de calor de 2 calentadores y 1 refrigerador L E Aux G C Y R Rc (nicamente TH6220D) [8] MCR29449 Rc Electricidad [1] R [R+Rc unidos por un puente] Y Interruptor automtico del compresor C 24 V CA [3] O/B Vlvula inversora [7] G Rel del ventilador Aux Rel auxiliar de calor [12] E Rel de emergencia de calor [12] L Cuando se fija en Em. Heat, enva un flujo de aire caliente. [11] Sistema de bomba de calor de 2 calentadores y 1 refrigerador (nicamente TH6320U) [8] Rc R Y C O/B G Aux/E L Sistema de bomba de calor de 2 calentadores y 2 refrigeradores (nicamente TH6320U) [9] Rc R Y C O/B G Y2 L
L Y2
Electricidad [1] [R+Rc unidos por un puente] Interruptor automtico del compresor (etapa 1) 24 V CA [3] Vlvula inversora [7] Rel del ventilador Interruptor automtico del compresor (etapa 2) Cuando se fija en Em. Heat, enva un flujo de aire caliente. [11]
C Y R Rc MCR29451
Sistema de bomba de calor de 3 calentadores y 2 refrigeradores (nicamente TH6320U) [10] Rc R Y C O/B G Aux/E Y2 L
Electricidad [1] [R+Rc unidos por un puente] Interruptor automtico del compresor 24 V CA [3] Vlvula inversora [7] Rel del ventilador Rel de calor auxiliar/de emergencia Cuando se fija en Em. Heat, enva un flujo de aire caliente. [11]
Aux G E
C Y R Rc MCR29450
E MCR29452 Electricidad [1] [R+Rc unidos por un puente] Interruptor automtico del compresor (etapa 1) 24 V CA [3] Vlvula inversora [7] Rel del ventilador Rel de calor auxiliar/de emergencia Interruptor automtico del compresor (etapa 2) Cuando se fija en Em. Heat, enva un flujo de aire caliente. [11]
L Y2 Aux G
C Y
R Rc
ESPAOL
MCR29453
69-1920EFS01
Gua de instalacin
Configuracin de instalacin
Siga el procedimiento que aparece a continuacin para configurar el termostato a fin de que se corresponda con el sistema de calefaccin y refrigeracin instalado, y seleccione las funciones segn lo desee.
Nmero de funcin Configuracin
1
Done Next
0
MCR29454
Para comenzar, mantenga presionados los botones s y FAN hasta que cambie la pantalla.
Presione s o t para cambiar la configuracin. Presione NEXT para avanzar a la siguiente funcin. Presione DONE para salir y guardar la configuracin.
Funciones de la Configuraciones y opciones (las que vienen Funciones de la configuracin Configuraciones y opciones configuracin desde la fbrica aparecen en negrita) que vienen desde la fbrica aparecen en negrita)
1 Tipo de sistema 0 1 2 3 4 5 6 7 8 9 10 2 3 Vlvula de conversin (terminal O/B) Control del ventilador (calefaccin) Velocidad del ciclo trmico de la primera etapa (CPH: ciclos por hora)* Velocidad de ciclo trmico/ ciclo de calor auxiliar de la segunda etapa (CPH)* Velocidad de ciclo de calor auxiliar (CPH)* nicamente TH6320U para sistemas de bombas de calor de 3 calentadores y 2 refrigeradores 8 Velocidad de ciclo de calor de emergencia (CPH)* 0 1 0 1 5 1 3 9 5 1 3 9 5 1 3 9
(las
Las reas sombreadas que aparecen abajo slo se utilizan para TH6320U/TH6220D o segn se indique.
1 calentador y 1 refrigerador convencional 1 bomba de calor con calentador y 1 refrigerador (sin calor aux.) Slo calor sistemas de 2 cables, vlvulas de separacin de tres cables (serie 20) y vlvulas de separacin normalmente abiertas Slo calor con ventilador Slo fro Bomba de calor con 2 calentadores y 1 refrigerador (con calor aux.) 2 calentadores y 2 refrigeradores convencionales 2 calentadores y 1 refrigerador convencional 1 calentador y 2 refrigeradores convencionales Bomba de calor con 2 calentadores y 2 refrigeradores (sin calor aux.) nicamente en TH6320U Bomba de calor con 3 calentadores y 2 refrigeradores (con calor aux.) nicamente en TH6320U Vlvula de conversin (terminal O/B con Electricidad durante la refrigeracin) Vlvula de conversin (terminal O/B con Electricidad durante la calefaccin) Sistemas de calefaccin de gas o de aceite (el equipo controla el ventilador para calefaccin) Sistema de calefaccin elctrico (el termostato controla el ventilador para calefaccin) Para sistemas de calefaccin de gas o de aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de ms de un 90% de efectividad Para sistemas de calefaccin elctricos Para sistemas de calefaccin de gas o de aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de ms de un 90% de ectividad Para sistemas elctricos Para sistemas de calefaccin de gas o de aceite de menos de un 90% de efectividad Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de ms de un 90% de efectividad Para sistemas elctricos
9 1 3 5
Para calor de emergencia elctrica Para sistemas de vapor o de gravedad Para sistemas de agua caliente y sistemas de ms de un 90% de efectividad Para sistemas de calefaccin de gas o de aceite de menos de un 90% de efectividad
ESPAOL
Recomendado para la mayora de los compresores [otras opciones de rango de ciclos: 1, 2, 4, 5 6 CPH]
69-1920EFS01
Configuracin de instalacin
Funciones de la configuracin Configuraciones y opciones (las que vienen desde la fbrica aparecen en negrita)
Las reas sombreadas que aparecen abajo slo se utilizan para TH6320U/TH6220D o segn se indique.
10 Rango de ciclos del compresor de la etapa 2 (CPH) Otras opciones de conversin manual/automtica Adaptive Intelligent Recoveay Visor de temperatura Proteccin del compresor Formato del programa Limitador del rango de temperatura del sistema de calefaccin Limitador del rango de temperatura del sistema de refrigeracin 3 Recomendado para la mayora de los compresores [otras opciones de rango de ciclos: 1, 2, 4, 5 6 CPH] Conversin manual (calor/fro/apagado) Conversin automtica (calor/fro/apagado) ** Vea la pgina 8 Conversor automtico nicamente (Auto) ** Vea la pgina 8 Encendido ** Vea la pgina 8 Apagado Fahrenheit Celsius Tiempo de apagado de 5 minutos para el compresor ** Vea la pgina 8 [otras opciones: tiempo de apagado de 0, 1, 2, 3 o 4 minutos] 5/2 (programable los das de semana y los fines de semana) 5/1/1 (programable los das de semana, sbados y domingos) La configuracin mxima de temperatura es de 90 F (32 C) [otras opciones: 40 F a 89 F (4,5 C a 31,5 C)] La configuracin mnima de temperatura es de 50 F (10 C) [otras opciones: 51 F a 99 F (10,5 C a 37 C)]
12
0 1 2 1 0 0 1 5 0 1 90
13 14 15 16 27
28
50
10
Para comenzar, mantenga presionados los botones s y t hasta que cambie el visor
0
MCR29455
Presione s / t para encender o apagar el sistema. Presione NEXT para avanzar hacia la prxima prueba. Presione DONE para finalizar la prueba del sistema.
30
40
Sistema de ventilacin
ESPAOL
PRECAUCIN: Durante la prueba, se desactiva la proteccin del compresor. Para evitar daos en el equipo, no permita que el compresor funcione a velocidades altas. 7 69-1920EFS01
Gua de instalacin
Funciones especiales
Conveasor automtico (configuracin 12): Cuando el sistema est configurado en Auto, el termostato elige automticamente cundo calentar o enfriar, dependiendo de la temperatura interior. El termostato ajustar automticamente las configuraciones de calor y fro a fin de mantener una separacin de 3 grados (fija). Nota: Si selecciona Auto Changeover Only (slo conversin automtica), la configuracin del termostato permanecer bloqueada en la posicin Auto, de modo que el usuario no pueda cambiarla a Em.Heat, Heat, Cool u Off. Adaptive Intelligent Recovery (configuracin 13): Permite al termostato saber cunto tiempo requiere el sistema de aire acondicionado para alcanzar las configuraciones de temperatura programadas a fin de alcanzar la temperatura deseada a la hora programada. Proteccin del compresor (configuracin 15): Hace que el compresor espere unos minutos antes de reiniciarse, para prevenir daos. Durante el tiempo de espera, el mensaje Cool On o Heat On (slo para las bombas de calor) aparecer parpadeando en la pantalla del visor.
Especificaciones
Rangos de temperatura Calor: 40 F a 90 F (4,5 C a 32 C). Fro: 50 F a 99 F (10 C a 37 C) Temperatura ambiente operativa 32 a 120 F (0 a 48,9 C) Temperatura de embalaje -20 a 120 F (-28,9 C a 48,9 C) Humedad relativa de funcionamiento 5% a 90% (no condensable) Dimensiones 3-9/16" de altura x 5-13/16" de ancho x 1-1/2" de profundidad 91 mm de altura x 147 mm de ancho x 38 mm de profundidad Rangos elctricos Terminal W Calefaccin (Powerpile) Y Refrigeracin Y2 Refrigeracin G Ventilador O/B Conversor E Calor de emergencia L Salida Voltaje (50/60 Hz) 20-30 V CA 750 mV CC 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA 20-30 V CA Corriente 0,02 -1,0 A 100 mA CC 0,02 -0,5 A 0,02 -1,0 A 0,02 -1,0 A 0,02 -0,5 A 0,02 -0,5 A 0,02 -1,0 A 0,02 -0,5 A
Soluciones para automatizacin y control Honeywell International Inc. Honeywell Limited-Honeywell Limite 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V4Z9 http://customer.honeywell.com