Vous êtes sur la page 1sur 6

Supply and Installation of Zn/Al Roof cover and Roof Plumbing for Nuwara-Eliya District Secretariat Roof

CONTRACT NO : ES/C1377/149/S1684/2008/648

BlueScope Lysaght Lanka (Pvt) Ltd., No. 26 & 27, Sapugaskanda Industrial Estate Sapugaskanda Sri Lanka Telephone+ 94 11 2400611 - 17 + 94 11 2400618 Facsimile www.bluescopesteel.com

PREOGRESS REPORT
Name of Company Name of Client Project Date Project No. Location : BlueScope Lysaght Lanka (Pvt) Ltd ( BSL) : State Engineering Corporation : Supply and Installation of Zn/Al Roof cover and Roof Plumbing for NuwaraEliya District Secretariat Roof : 16.12.2011 : ES/C1377/149/S1684/2008/648 : Site at Nuwara-Eliya

Objectives / Agenda : 1. Inspection of Roof for water leakages 2. Re-Check the mis-installation of roof sheeting and accessories : Participates 1. Mr. Sarath Gamage BSL 2. Mr. A. I Koys - BSL

3. Mr.A.M.S.T.B.Alahakoon ( SEC) 4. Mr. Senarathne ( SEC)

Roof Layout

Page 1 of 6

No:

Locationphotos

Description

BSLaction

SECaction

470mmgirtvalleygutteris used.Roofslopeisabout27 degrees.Itsheavyrainy areawithwind.Thisisthe highestbuildinginthearea. Thispoint(A)leakage causedbyoverflowingof valleygutter.

Highercapacityvalleygutter shouldbeprovided.Inform SECthatthesecondary structureitselfnotprovideda valleyforthevalleygutter andthereforeaboveaction willnotbeapermanent solution.

Ifpossibleprovidingadrop (valley)forthevalleygutterin secondarystructure. Providingsafetyaccessfor rectification. Materialdelivery.

Apronflashingisnotfitted well.Thiscanbecorrected.

Refixing

Providingsafetyaccessfor rectification.

Page 2 of 6

Thiscouldntbeidentified. Apronhastoremoveand checkswhenrainy.

Onceattendedforother rectification,thisareatobe checkedremovingsheeting& insulationandthenmaterial tobeordered.

Providingsafetyaccessfor checking&rectification.

Althoughclienthighlight thereisaleakage,no evidencetoidentify&no missinstallationobserved. Clientisinstructedtodivert theoutlettothegutter.

Tocheckputtingwateronce attendedforother rectification&ordermaterial ifrequired.

Providingsafetyaccessfor checking&rectification. Providewater&ahosefor checking. Divertingthewateroutlettothe gutter.

Page 3 of 6

Althoughclienthighlight thereisaleakage,no evidencetoidentify&no missinstallationobserved. Clientisinstructedtodivert theoutlettothegutter.

Tocheckputtingwateronce attendedforother rectification&ordermaterial ifrequired.

Providingsafetyaccessfor checking&rectification. Providewater&ahosefor checking. Divertingthewateroutlettothe gutter.

Lesserlapb/nupperroof andbellowroof.

Upperroofvalleygutter& sheetingtobeextended.

Providingsafetyaccessfor rectification. Convincethearchitect&have thepermissiontoextentthe gablecap&roofingofupper roofuptolowerroofsheeting.

Page 4 of 6

Sameaboveplaceisvisited fromunderside.Valley fixingofroofingfasteners areobserved.

Sameasabove.Valleyfixings shouldbeproperlysealed.

Providingsafetyaccessfor rectification.

Wrongpunching&fillingof fasteningpoints.

Tobefilledwithsiliconalong withafastener.

Providingsafetyaccessfor rectification.

Page 5 of 6

Supply and Installation of Zn/Al Roof cover and Roof Plumbing for Nuwara-Eliya District Secretariat Roof
CONTRACT NO : ES/C1377/149/S1684/2008/648B-PF1097

BlueScope Lysaght Lanka (Pvt) Ltd., No. 26 & 27, Sapugaskanda Industrial Estate Sapugaskanda Sri Lanka Telephone+ 94 11 2400611 - 17 + 94 11 2400618 Facsimile www.bluescopesteel.com

Prepared by ( Signature) ( BSL) Gayan Attanayake

Date:

29.12.2011

Verified by (Signature) ( SEC) A.M.S.T.B.Alahakoon

Date:

Page 6 of 6