Dust wiper function Fine spatter is collected into the fiber aggregate to reduce contamination on the sliding section and prevent entry into the cylinder body.
Coil scraper
CC-936A
RCC2-G4 Series
Specifications
Descriptions
Bore size Actuation Max. working pressure Min. working pressure Withstanding pressure Ambient temperature Port size Working piston speed Cushion Lubrication Turning angle Rotational direction Rod revolvable angle tolerance (clamp): Default Retract side Pressurized area mm2 Push side 1 201 314 377 490 603 804 mm/s MPa MPa MPa C M5 mm 20 25
* Custom-order part
RCC2-G4
32 0.2 1.6 10 to 60 (no freezing) Rc/8 50 to 200 Rubber cushioned Not required (use turbine oil Class 1 ISO VG32 for lubrication.) 9010 Right / Left 0.9 1055 1256 1649 1963 0.7 2626 3117 Rc1/4 40 50 63 Double acting
Stroke length
Bore size (mm) 20 25 32 40 50 63 Stroke length (mm) 21, 31 25, 35 40, 70 Rotational section stroke (mm) 15 20 Clamp section stroke (mm) 10, 20 10, 20 20, 50
Switch specifications
* The T0/T5 switch can be used with 220 VAC. Contact CKD for working conditions.
Proximity 2 wire
Programmable controller, relay, Programmable I.C. (w/o light), serial connection controller
12/24 VDC 5 to 50 mA
110 VAC
5, 12, 24 VDC
110 VAC
7 to 20 mA 50 mA or less 20 mA or less 5 to 20 mA 0 mA
mA or less
Note 1: The max. load current of 20 mA is the value at 25 C. If the switchs working ambient temperature is hotter than 25 C, the max. value is lower than 20 mA. (5 to 10 mA at 60C)
RCC2-G4 Series
How to order
Without switch
How to order
RCC2-G4
With switch
00 00
A
20 20
21 21
R R T0H R
Symbol Descriptions Basic type Rod end flange type Head end flange type
A
RCC2-G4
Model no.
Mounting style
Mounting style
00 FA FB
Bore size
Stroke length
Stroke length
Rotational direction
Rotational direction
R L When clamped (PULL) from rod side: Turn 90 CW When clamped (PULL) from rod side: Turn 90 CCW
Axial lead Radial Contact wire lead wire T0H* T5H* T2H* T3H* T3PH* T2YH* T3YH* T2YD* Blank 3 5 T0V* T5V* T2V* T3V* T3PV* T2YV* T3YV* 1 m (standard) 3 m (option) 5 m (option) Reed
RCC2-G4-00-20-21-R-T2YD3-D
Model: Rotary clamp cylinder double acting spatter adherence prevention type A Mounting style : Basic type B Bore size : 20 C Stroke length : 21 mm D Rotational direction : When clamped (PULL) from rod side: Turn 90 CW E Switch model no. : Proximity type T2YD switch for strong magnetic field proof, lead wire length 3 m F Switch quantity : 2 pieces Switch quantity
Switch quantity
R H D One on rod end One on head end Two
RCC2-G4 Series
Dimensions 20, 25
F (TP) Z Y X R A+2 x stroke length B+2 x stroke length V C 2-EE
4-KA
P S MM
32 to 63
b
(HD) [ ](=RD+ST)
(TP)
X Z Y O
A+2 x stroke length B+2 x stroke length V+2 x stroke length C+ stroke length D 2-EE
a b
N 4-KA
P S MM
F G
K
R
KK [ ](=RD+ST)
(HD)
Note: The 50 and 63 switch groove differs from the above. Refer to the Pneumatic Cylinders I RCC2 Series.
Symbol Bore size
20 25 32 40 50 63
A
58.5 59.5 72 73 77 88
B
50.5 51.5 64 65 69 78
D
5.5 6 8 8.5 10.5 11
EE
M50.8 M50.8 Rc1/8 Rc1/8 Rc1/4 Rc1/4
F
36 40 45 52 64 77
G
49.5 57 71 84
H
24 24 33 33
K
47 51 60 69 86
KA
M6 depth 11 M6 depth 11
KK
M8 depth 15 M8 depth 15
L
10 10 15 15
M
10 10 14 14 17 22
MM
12 12 16 16 20 25
N
25.5 28 34 40 50 60
O
4.5 5 7 7
P
24 24 30 35 37 48
R
9 9 9 9 12 12
X
8 8 8 8 8 10
Y
4.5 4.5 6 6 6 8
V
48 49 61 62 66 75
N
Z
10.5 10.5 11 11 11 13
S
20 20 24 24 30 36
Switch symbol
Bore size
20 25 32 40 50 63
T2/3H, T2/3V HD RD TP
7 6 9 10 11 19 26 25 28 29 30 37 0 0 0 0 0 0
T0/5H, T0/5V HD RD TP
6 5 8 9 10 18 27 26 29 30 31 38 0 0 0 0 0 0
T*YH/T*YV HD RD
6 5 8 9 10 18 27 26 29 30 31 38
TP
5 5 5 5 5 5
HD
6 5 8 9 10 18
T2YD* RD
27 26 29 30 31 38
TP
11 11 11 11 11 11
Cylinder durability in an environment containing spatter is higher than a general cylinder. When using in an environment where The spatter adherence prevention agent is volatile. If the spatter prevention agent on the rod surface starts to dry, reapply
the agent to the rod surface. When using the support FA (rod side flange), the holder will protrude from the flange end.
Symbol bore size
20 25 32 40 50
spatter is not present, durability may be inferior to the general cylinder. Do not use this cylinder in environments free from spatter.
S
20 20 24 24 30 36
63