Vous êtes sur la page 1sur 4

New Products

Rotary clamp cylinder double acting spatter adherence prevention type


RCC2-G4 Series
New product
Overview
Spatter adherence prevention has been incorporated in the RCC2 Series configured of the square space-saving cylinder with the built-in rotary clamp mechanism.

Long life even in environments containing spatter


Features
A fiber aggregate (lube keeping structure) impregnated with spatter adherence prevention agent is used to prevent spatter from sticking and solidifying onto the piston rod during arc welding. A metal scraper (coil scraper) helps remove spatter adhering to the piston rod. The spatter adherence prevention agent is supplied steadily for a long time, improving durability over general cylinders used in spatter environments. Features of lube keeping structure Spatter adherence prevention agent supply/ absorption A capillary tube effect applies the spatter adherence prevention agent evenly and regularly to the sliding surface and also absorbs any excess.
Lube keeping structure

Lube keeping structure cross section ( 180)

Dust wiper function Fine spatter is collected into the fiber aggregate to reduce contamination on the sliding section and prevent entry into the cylinder body.

Coil scraper

Refer to safety precautions on Pneumatic Cylinders I catalog (No. CB-029SA).

CC-936A

RCC2-G4 Series
Specifications
Descriptions
Bore size Actuation Max. working pressure Min. working pressure Withstanding pressure Ambient temperature Port size Working piston speed Cushion Lubrication Turning angle Rotational direction Rod revolvable angle tolerance (clamp): Default Retract side Pressurized area mm2 Push side 1 201 314 377 490 603 804 mm/s MPa MPa MPa C M5 mm 20 25
* Custom-order part

RCC2-G4
32  0.2 1.6 10 to 60 (no freezing) Rc/8 50 to 200 Rubber cushioned Not required (use turbine oil Class 1 ISO VG32 for lubrication.) 9010 Right / Left 0.9 1055 1256 1649 1963 0.7 2626 3117 Rc1/4 40 50 63 Double acting

Stroke length
Bore size (mm) 20 25 32 40 50 63 Stroke length (mm) 21, 31 25, 35 40, 70 Rotational section stroke (mm)  15 20 Clamp section stroke (mm) 10, 20 10, 20 20, 50

Switch specifications

1 color/2 color indicator/strong magnetic field proof


Descriptions
Applications Output method Power voltage Load voltage Load current Light Leakage current

* The T0/T5 switch can be used with 220 VAC. Contact CKD for working conditions.

Proximity 3 wire T3PH/T3PV T2H/T2V T2YH/T2YV T3H/T3V T3YH/T3YV (custom order)


Programmable controller 10 to 30 VDC 5 to 20 mA (Note 1) LED (ON lighting) Red/green LED (ON lighting) Programmable controller and relay NPN output PNP output NPN output 10 to 28 VDC 30 VDC or less 100 mA or less LED (ON lighting) Green LED (ON lighting) 10 A or less 50 mA or less Red/green LED (ON lighting)

Proximity 2 wire

Reed 2 wire T0H/T0V


Programmable controller and relay

Proximity 2 wire T5H/T5V T2YD

Programmable controller, relay, Programmable I.C. (w/o light), serial connection controller

12/24 VDC 5 to 50 mA

110 VAC

5, 12, 24 VDC

110 VAC

24 VDC 10% Red/green LED (ON lighting) 1.0 mA or less

7 to 20 mA 50 mA or less 20 mA or less 5 to 20 mA 0 mA

LED (ON lighting)

 mA or less

Note 1: The max. load current of 20 mA is the value at 25 C. If the switchs working ambient temperature is hotter than 25 C, the max. value is lower than 20 mA. (5 to 10 mA at 60C)

RCC2-G4 Series
How to order
Without switch

How to order

RCC2-G4
With switch

00 00
A

20 20

21 21

R R T0H R
Symbol Descriptions Basic type Rod end flange type Head end flange type
A

RCC2-G4
Model no.

Mounting style

Mounting style
00 FA FB

Bore size

Bore size (mm)


20 25 32 40 50 63 20 25 32 40 50 63

Stroke length

Stroke length (mm)


Bore size 20, 25 32, 40 20, 25 32, 40 50, 63 50, 63 Rotational section Clamp section  15  15 20 20 10 10 20 20 20 50 21 25 31 35 40 70

Stroke length

Rotational direction

Rotational direction
R L When clamped (PULL) from rod side: Turn 90 CW When clamped (PULL) from rod side: Turn 90 CCW

Switch model no.

Switch model no.


Indicator  color indicator type Without indicator light  color indicator type Proximity Lead wire 2-wire 2-wire 3-wire 2-wire 3-wire

Axial lead Radial Contact wire lead wire T0H* T5H* T2H* T3H* T3PH* T2YH* T3YH* T2YD* Blank 3 5 T0V* T5V* T2V* T3V* T3PV* T2YV* T3YV* 1 m (standard) 3 m (option) 5 m (option) Reed

<Example of model number>

RCC2-G4-00-20-21-R-T2YD3-D

Model: Rotary clamp cylinder double acting spatter adherence prevention type A Mounting style : Basic type B Bore size : 20 C Stroke length : 21 mm D Rotational direction : When clamped (PULL) from rod side: Turn 90 CW E Switch model no. : Proximity type T2YD switch for strong magnetic field proof, lead wire length 3 m F Switch quantity : 2 pieces Switch quantity

1 color indicator type (custom order) 3-wire 2 color indicator type

Strong magnetic field proof 2-wire

*Lead wire length (m)

How to order switch SW T0H

Switch quantity
R H D One on rod end One on head end Two

Switch model no. (Above E )

RCC2-G4 Series
Dimensions 20, 25
F (TP) Z Y X R A+2 x stroke length B+2 x stroke length V C 2-EE

4-KA

P S MM

32 to 63
b

Rotational KK direction R L (clamp) (rod retract)


F H L
a

(HD) [ ](=RD+ST)

(TP)

X Z Y O

A+2 x stroke length B+2 x stroke length V+2 x stroke length C+ stroke length D 2-EE
a b

N 4-KA

P S MM

F G

K
R

Rotational L direction (clamp) (rod retract)


C
24 26 27 29 29 38

KK [ ](=RD+ST)

(HD)

Note: The 50 and 63 switch groove differs from the above. Refer to the Pneumatic Cylinders I RCC2 Series.
Symbol Bore size
20 25 32 40 50 63

A
58.5 59.5 72 73 77 88

B
50.5 51.5 64 65 69 78

D
5.5 6 8 8.5 10.5 11

EE
M50.8 M50.8 Rc1/8 Rc1/8 Rc1/4 Rc1/4

F
36 40 45 52 64 77

G
49.5 57 71 84

H
24 24 33 33

K
47 51 60 69 86

KA
M6 depth 11 M6 depth 11

KK
M8 depth 15 M8 depth 15

L
10 10 15 15

M
10 10 14 14 17 22

MM
12 12 16 16 20 25

N
25.5 28 34 40 50 60

O
4.5 5 7 7

P
24 24 30 35 37 48

R
9 9 9 9 12 12

X
8 8 8 8 8 10

Y
4.5 4.5 6 6 6 8

V
48 49 61 62 66 75

N
Z
10.5 10.5 11 11 11 13

S
20 20 24 24 30 36

M6 depth 11 M10 depth 15 M6 depth 11 M10 depth 15 M8 depth 13 M12 depth 15

103 M10 depth 25 M16 depth 21

Switch symbol

Bore size
20 25 32 40 50 63

T2/3H, T2/3V HD RD TP
7 6 9 10 11 19 26 25 28 29 30 37 0 0 0 0 0 0

T0/5H, T0/5V HD RD TP
6 5 8 9 10 18 27 26 29 30 31 38 0 0 0 0 0 0

T*YH/T*YV HD RD
6 5 8 9 10 18 27 26 29 30 31 38

TP
5 5 5 5 5 5

HD
6 5 8 9 10 18

T2YD* RD
27 26 29 30 31 38

TP
11 11 11 11 11 11

Safety precautions Cautions

Refer to safety precautions on Pneumatic Cylinders I catalog (No. CB-029SA).

Cylinder durability in an environment containing spatter is higher than a general cylinder. When using in an environment where The spatter adherence prevention agent is volatile. If the spatter prevention agent on the rod surface starts to dry, reapply
the agent to the rod surface. When using the support FA (rod side flange), the holder will protrude from the flange end.
Symbol bore size
20 25 32 40 50

spatter is not present, durability may be inferior to the general cylinder. Do not use this cylinder in environments free from spatter.

S
20 20 24 24 30 36

63

Vous aimerez peut-être aussi