Introduction
Purpose is to provide:
A prompt for preparing data for new installations. A datapack for installers. A data entry form to capture additional as-built An as-built record with sign-off.
data.
Associated forms included in this file are: Installation Inspection Form Customer Acceptance Form Remedial Action Form Navigation: The Master Site Data column lists entries required. Click on a + tab at the far left of the screen to open up required data entry rows. Click tab to close. The Build / As-Built Data column is for data entry. Build data is data to be entered at the planning (datapack prep) stage. As-built data is data to be entered at site, mostly from Portal. The Portal column highlights the data to be entered into Portal and data to be entered from Portal. The Comments column is to capture any additional data.
See the Example Form for additional guidance. Forms can be printed. Important! Please provide feedback on the use of these forms. Feedback is needed to provide guidance on what improvements should be made to assist the application and usability of these forms. Please send feedback to: Director Installation Practices Director of Services, Americas
Commercial-In-Confidence
For Site:
General Instructions:
Portal Entry To / into Portal To = Enter Record Enter from Portal From = From To
To To To To
Comments
To To To To To
To To To
To To To To To To To From To To
Commercial-In-Confidence
Harris Stratex Networks STM1/OC3 Tributary Ethernet Ports AUX Auxiliary port Type, port settings, name Circuit name Alarm I/O Alarm actions Date/Time (Specify Date/Time setting) BER Circuit Checks Trib-trib BER check (Specify the trib[s] and period) Alarms exit check Active alarms yes/no Ground checks Single point bldg ground y/n Master Ground Bar resistance Rack to MGB resistance -48V PSU to MGB resistance Tower ground resistance(s) Other resistance readings Meter used Site Inspection Report completed yes/no Hardware Installation completed Name: Signature: Date:
To To
To
From
From
Node Installation & Tests completed Name: Signature: Date: Completion Comments
Commercial-In-Confidence
Joeseph Brown 021 362 700 15-Sep-05 18-Sep-05 Existing Yes Yes Yes Intruder alarm has been disabled Yes Build / As-Built Data
IDU 20x ODU 300hp E116 Plaza Eastxxx Southxxx 021 362 701 021 362 702 10km East of Masterton Off Murrays Road 1A Directly under terminal E10 LES00934567 Provide and install 5A Cct Breaker on supply panel at top of rack
Portal Entry To / into Portal To = Enter Record From = Enter from Portal From
To To To To To See attached map
Comments
Networking Terminal IP address Subnet mask Static or dynamic routing Static routing data DHCP yes/no; address range Trap destinations Link/Radio Link name/number Remote end site name Remote end terminal/node name Local antenna type Local antenna diameter Antenna serial number Height on tower / pole mount ID Initial pointing (compass/map ref) Polarization ODU direct mounting, yes/no ODU serial number ODU cable length required Protected yes/no Link protection type Trib protection type (TT or TA) Tx frequency Rx frequency T/R spacing Tx power Detected forward power Capacity Modulation ATPC yes/no ATPC data Expected RSL Indicated RSL Expected RSSI Indicated RSSI Expected fade margin Measured fade margin G.826 link check Alarms check Performance check E1 Tributaries Bal or Unbal
To To To To To
Plaza-Weston Weston E109 VHLP2-180-EX 0.6M AN35239 28M 183 degrees Vertical Yes SNA7687988 40m No N/A N/A 17.85 GHz 18.25 GHz 400 MHz 17 dBm 17.1 dBm 20xE1 16 QAM No -51 dBm -50 dBm 1.25 1.27 35 dB 37 dB Zero errors over 14 hours No active alarms All indications normal
To To To
To To To To To To To From To To To
Unbal
To
Commercial-In-Confidence
Comments
Input 2, active condition Output 1, active condition Output 2, active condition Output 3, active condition Output 4, active condition Alarm I/O Alarm actions Destination IP address, slot, and output. 192.168.2.1, slot 4, output 2. Trigger(s). AUX alarm input 1.
To
At commissioning check that the destination output (bell) at Belmont activates when the intruder alarm is activated. Also check that the alarm event is raised at the NOC.
Destination IP address, slot, and output. Trigger(s). Destination IP address, slot, and output. Trigger(s). Destination IP address, slot, and output. Trigger(s). Destination IP address, slot, and output. Trigger(s). Alarm actions Date/Time (Specify Date/Time setting) BER Circuit Checks Trib-trib BER check (Specify the trib[s] and period) Alarms exit check Active alarms yes/no Ground checks Single point bldg ground y/n Master Ground Bar resistance Rack to MGB resistance -48V PSU to MGB resistance Tower ground resistance(s) Other resistance readings Meter used Hardware Installation completed Name: Signature: Date:
To To To To
To
From
No active alarms
From
Yes 0.62 ohms 0.15 ohms 0.27 ohms Not possible to measure. Cannot get meter jaws around the ground straps. Prova clamp-on, model DX Serial number 00458
Node Installation & Tests completed Name: Signature: Date: Completion Comments Joesphine Brown 18 September 2005 Road access is OK. Shelter door hinges very corroded. Checked diesel generator & all OK
Commercial-In-Confidence
For Site:
Comments
Commercial-In-Confidence
Received Yes/No
Category
Signed By: Customer Name: Signature: Title: Date: Harris Stratex Networks Name: Signature: Title: Date:
Commercial-In-Confidence
Signed As Completed Customer Name: Signature: Title: Date: Harris Stratex Networks Name: Signature: Title: Date:
Commercial-In-Confidence