Vous êtes sur la page 1sur 5

www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Specifier's comments: Page: Project: Sub-Project I Pos. No.

: Date:

PROFIS Anchor 2.0.7


1

-|-

08/02/2012

1. Input data

Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report:: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile Base material: Reinforcement:

HDA-T, M12x125/30 h ef = 125 mm 8.8 ESR 1546 01/11/2005 | design method ACI 318 / AC 193 e b = 0 mm (no stand-off); t = 16 mm Custom; fyk = 248.20 N/mm; l x x l y x t = 500 x 400 x 16 mm (Recommended plate thickness: not calculated) Rectangular plates and bars (AISC); (L x W x T) = 197 mm x 10 mm x 0 mm cracked concrete , , fc' = 5076 psi; h = 200 mm condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar

Geometry [mm] y z

500 200 t=16 h nom=133

200

200

400

h = 200

lx = 500 140

140

320

Loading [kN, kNm] Governing loads Governing loads (Load case 1) N Vx Vy Mx My Mz 0.000 30.600 0.000 0.000 4.650 0.000

Eccentricity (structural section) [mm] e x = 0; e y = 0 Seismic loads (cracked concrete assumed; categories C, D, E, or F): no

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.7


2

-|-

08/02/2012

2. Load case/Resulting anchor forces


Load case (governing): Anchor reactions [kN] Tension force: (+Tension, -Compression) Anchor 1 2 3 4 Tension force 6.094 0.055 6.094 0.055 Shear force 7.650 7.650 7.650 7.650 Shear force x 7.650 7.650 7.650 7.650 Shear force y 0.000 0.000 0.000 0.000 1 3 Tension

y 4 Compression x

max. concrete compressive strain []: 0.02 max. concrete compressive stress [N/mm]: 0.71 resulting tension force in (x/y)=(-157/0) [kN]: 12.300 resulting compression force in (x/y)=(221/0) [kN]: 12.300

3. Tension load
Proof Steel Strength* Pullout Strength* Concrete Breakout Strength** Load Nua [kN] 6.094 6.094 12.298 Capacity fNn [kN] 50.696 46.310 66.588 Utilization bN [%] = Nua /fNn 12 13 18 Status OK OK OK

* most unfavorable anchor **anchor group (anchors in tension) Steel Strength Nsa [kN] 67.595 Pullout Strength Np [kN] 49.998 (fc'/2500) 1.425
0.5

f 0.750

fN sa [kN] 50.696

Nua [kN] 6.094

f 0.650

fNpn,f'c [kN] 46.310

Nua [kN] 6.094

Concrete Breakout Strength ANc [mm ] 344942 e c1,N [mm] 157 Nb [kN] 83.039
2

ANco [mm ] 140553 y ec1,N 0.544 f 0.650

c [mm] 140 e c2,N [mm] 0 fNcbg [kN] 66.588

c ac y ec2,N 1.000 Nua [kN] 12.298 y ed,N 0.924 y cp,N 1.000 k cr 24.000

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.7


3

-|-

08/02/2012

4. Shear load
Proof Steel Strength* Steel failure (with lever arm)* Pryout Strength** Concrete edge failure in direction x+** * most unfavorable anchor **anchor group (relevant anchors) Steel Strength Vsa [kN] 82.999 Pryout Strength ANc [mm ] 344942 e c1,V [mm] 0 Nb [kN] 83.039
2

Load V ua [kN] 7.650 N/A 30.600 30.600

Capacity fV n [kN] 53.950 N/A 263.644 36.435

Utilization bV [%] = Vua /fVn 14 N/A 12 84

Status OK N/A OK OK

f 0.650

fVsa [kN] 53.950

Vua [kN] 7.650

ANco [mm ] 140553 y ec1,N 1.000 f 0.700

c [mm] 140 e c2,V [mm] 0 fVcpg [kN] 263.644

k cp 2.000 y ec2,N 1.000 Vua [kN] 30.600 y ed,N 0.924 y cp,N 1.000 k cr 24.000

Concrete edge failure in direction x+ le [mm] 125 y ed,V 1.000 Vb [kN] 34.700 d o [mm] 21 y a,V 1.000 f 0.700 c 1 [mm] 133 e c,V [mm] 0 fVcbg [kN] 36.435 AVc [mm ] 120000 y ec,V 1.000 Vua [kN] 30.600
2

AVco [mm ] 80000 y c,V 1.000

5. Combined tension and shear loads


bN = N u /fN n 0.185 bNV = bN + bV <= 1
z z

bV = V u /fVn 0.840

z 5/3

Utilization bN,V [%] 81

Status OK

6. Allowable Stress Design (Refer to ICC-ES Evaluation Service Report)


anchor group relevant (tension); anchor group relevant (shear) Tension [kN] including Reference for load ACI318 Section D.4.4 ACI318 Section D.4.5 Rallow,ASD = R d / a T/T allow,ASD + V/V allow,ASD <= 1.2 seismic excluding seismic 47.563 42.960 including seismic Shear [kN] excluding seismic 26.025 23.506

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.7


4

-|-

08/02/2012

7. Warnings
Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout or pryout strength governs. IBC 2006, Section 1908.1.16, requires that the governing design strength of an anchor or group of anchors be limited by ductile steel failure, if this is NOT the case, ACI 318-D Section D.3.3.5 requires that the attachment that the anchor is connecting to the structure shall be designed so that the attachment will undergo ductile yielding at a load level corresponding to anchor forces no greater than the design strength of anchors specified in ACI 318-D section D.3.3.3, or the minimum design strength of the anchors shall be at least 2.5 times the factored forces transmitted by the attachment. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI318 or the relevant standard! The anchor plate is assumed to be sufficiently stiff in order to be not deformed when subjected to the actions!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

www.hilti.us Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:

PROFIS Anchor 2.0.7


5

-|-

08/02/2012

8. Installation data
Anchor plate, steel: Custom; f yk = 248.20 N/mm Profile: Rectangular plates and bars (AISC), 197 mm x 10 mm x 0 mm Hole diameter in the fixture: df = 23 mm Plate thickness (input): 16 mm Recommended plate thickness: not calculated Anchor type and diameter: HDA-T, M12x125/30 Installation torque: 0.080 kNm Hole diameter in the base material: 22 mm Hole depth in the base material: 133 mm Minimum thickness of the base material: 191 mm

100.0 3 4 200.0

90.0 250.0 250.0

90.0

Coordinates Anchor [mm] Anchor x y 1 -160 -100 2 160 -100 3 -160 100 4 160 100

c -x 140 460 140 460

c +x 460 140 460 140

c -y 200 200 400 400

c +y 400 400 200 200

Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

100.0

200.0