DOCWin 2.1
Curva Tempo-Corrente FFF 1E4s
1E3s
10MAs
100s
1MAs
10s
0.1MAs
1s
0.1s
1E-2MAs
1E-2s
1E-3MAs
0.1kA
1kA
10kA
0.1kA
1kA
10kA
ABB SACE - 1 01 - 11 - 21
Agenda
General features: what does DOCWin 2.1 calculate
Installation: system requirements and installation procedure Learning: instruments to learn DOCWin 2.1 Assistance: how to contact ABB SACE
ABB SACE - 2
General features
ABB SACE - 3
General features
Unlimited number of nodes MV/LV networks Radial and meshed networks Several distribution systems
ABB SACE - 4
General features
Load-flow
Its possible to size all objects according to the the power of the transformer or (without flag) according to the load
ABB SACE - 5
General features
Configurations
You can create different configuration in one single projects Breakers can be set ON and OFF in each configuration.
ABB SACE - 6
General features
Configuration creation
Unlimited number of possible configurations Manual switch between configurations
ABB SACE - 7
General features
Load-flow
Its also possible to consider loads at constant current: a way much closer to designer habits
ABB SACE - 8
General features
Load-flow
In case of single phaseloads, DOC can select phase in order to optimize phase balancing
ABB SACE - 9
General features
When sizing Utilities and busbars its possible to calculate the capacitor power
ABB SACE - 10
General features
Network calculations
voltage and load current in every point of the network
Load-flow:
ABB SACE - 11
General features
Automatic dimensioning
Protection relation
Co-ordination relations
General features
User friendly
General features
Complete documentation
All the data are exportable in the most common data exchange formats
Export of single-line diagram in DWG/DXF format Export of reports in RTF and PDFformat Export of curves in WMF format
ABB SACE - 14
ABB SACE - 15
Project
CAD Program
Network drawing
Database ABB
Non competitors Database (Zucchini) User database
Codes list
ABB SACE - 17
Power supply
Supply Generator Two windings transformer Three windings transformer
ABB SACE - 18
Objetcs
Impedance Cable Busway
Busbar
ABB SACE - 19
LV cable
Special window... Cable selection Method of installation
ABB SACE - 20
ABB SACE - 21
Protection devices
Circuit-breaker Residual current circuit - breaker Fuse
ABB SACE - 22
Circuit breakers
Filtered or free selection Co-ordination Protection Pre-definition of:
Type Execution Release Idn
ABB SACE - 23
ABB SACE - 24
ABB SACE - 25
-L1
Generic load
All necessary informations are in the same window All possibilities: -by apparent power and pf -by active/reactive power -by current and pf -by active power and pf
ABB SACE - 26
Motors
Motor
ABB SACE - 27
Motors
Motor ABB motors database (from 0.18 to 710 kW )
ABB SACE - 28
Motors
Motor Starter co-ordination and protection
ABB SACE - 29
Motors
ABB SACE - 30
Light load
You can define:
Lamp type/technology Power Number of lamps Distances
ABB SACE - 31
Multimeter
All network calculations available in every point of the installation
ABB SACE - 32
ABB SACE - 33
Data input
DOCWin 2.1 helps the user during the data input ...
Data input
... showing the default values stored in the prototype ... with the databases of the electrical machines ... with a customized dialog window for each object ... by asking for the missing data during the automatic dimensioning
ABB SACE - 34
Network congruity
DOCWin 2.1 verifies the congruity of the network and signals every anomalous situation
Data input
Network congruity Automatic dimensioning
ABB SACE - 35
Load - Flow
DOCWin 2.1 calculates the load current for each object and the voltage level at each node using the Newton-Raphson method
Data input
Network congruity Automatic dimensioning
Load- Flow
ABB SACE - 36
Cable sizing
DOCWin 2.1 sizes and checks the cables in compliance with the following Standards: IEC 60364-5-23
VDE 298-4 NFC 15-100 CEI 64-8
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing
ABB SACE - 37
Short-circuit
DOCWin 2.1 calculates the maximum and minimum short-circuit currents for LLL, LL, LN, L-PE in compliance with:
IEC 60909-1
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit
Devices selection
DOCWin selects circuit-breakers and fuses taking in account the protection of cables, busways, switch disconnectors and residual current circuit breakers
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
Note:
Restrictions do not always allow a solution !
ABB SACE - 39
- Long discrimination or back-up chains - Protection against indirect contacts with wrong function - Ib too close to Iz of the protected cable - wrong Standard selection - ...
Devices selection
DOCWin selects circuit-breakers taking in account discrimination and back-up relations between breakers
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
Note:
Tables used by DOCWin are valid up to 436V Computation time is function of the number of linked breakers and growths like a factorial funtion
ABB SACE - 40
Manual refinement
The user shall check the solution proposed by DOCWin 2.1 to optimize it. In particular, the user can ...
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
... Select manually the objects ... Oversize the cables and the busways ... Select the tapping of the transformers ... Lock the manually choosen objects ... Set the relays
Manual refinement
ABB SACE - 41
Drawing curves
Time-current curves Specific let-through energy curves Limitation curves
Curva Picco Curva Curva Tempo-Corrente LLL LLL Energia specifica passante 1E3kA 1E4s 1E4MAs 1E3s
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
1E-2s
0.1MAs 0.1kA 1kA10kA 0.1kA 10kA 1kA 100kA 100kA 10kA
Documentation printouts
Single-line diagram Report Curves Settings
Curva Tempo-Corrente FFF 1E4s
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
Reference voltage=400 V 1E3s Electronic rele: -QF1 S6X 400 PR212-LSI R400 L: Setting: 0.67 Curva: 18 100s S It=cost Setting: 9.5 Curva: 0.35 I Setting: 12 10s TM Rele: 1s LT: INST:
0.1s
-QF2 T3N 250 R250 Setting: 212.499 [A] Preload: 202.272 [A] Setting: 2500 [A]
Documentation printouts
1E-2s
0.1kA
1kA
10kA
Data export
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
Documentation printouts
Data export
Data export
Single-line diagram drawing
Data input
Network congruity Automatic dimensioning
Load- Flow
Cables, busways, trafos sizing Short-circuit Devices selection
Documentation printouts
Data export
Learning
ABB SACE - 46
Learning
User manual
ABB SACE - 47
Learning
Video course
ABB SACE - 48
Installation
ABB SACE - 49
Installation
System requirements
OS from Win95 to Win2000 Unlimited number of installations Administrator privileges required At least 60 Mb of hard disk space Be sure no other application (anti-virus program) are running during the installation !!!!!
ABB SACE - 50
Installation
Installation procedure
Double-click Start.exe
ABB SACE - 51
Assistance
ABB SACE - 52
Assistance
Call center
claudio.brazzola@it.abb.com claudio.bizzo@it.abb.com E-mail is the best way to communicate efficiently with the working group
Precise explanations of the problem and an example file attached to the e-mail help us to solve the problem
ABB SACE - 53
Assistance
http:\\bol.it.abb.com
to ask for a free version of the program to be informed about the news
ABB SACE - 55