Vous êtes sur la page 1sur 10

EAGLE TECHNOLOGY

WLQ Series starter for high voltage case motor


Foreword Thank you for selecting WLQ series starter for high voltage case motor of Worldwide Electric Co., Ltd. This manual provides the user with the relevant precautions for installation, abnormality diagnosis, routine maintenance and safe operation. Please read this manual carefully before installation to ensure correct installation and operation of this product. As regards our products and our service, the staff of our company firmly believes the principle that the customer is God. In case of any difficulty or unsettled problem arising in operation, please contact the dealer or directly contact us. Please keep this manual well, which will be helpful for maintenance, repair and other applications in future.

Unpacking for check


WLQ series starter for high voltage case motor has passed the strict quality inspection and performance testing before ex-factory. After it arrives at the installment site please check whether there is any damage due to careless transportation, and whether the model of the product is the same as the ordered one before unpacking. As the product is continuously upgraded, there may be several parts or words of the equipment and product, which do not conform to the advertising materials; please consult us if the equipment meets with such problems. After opening the box, check if there are qualified mark, product description, product warranty manual and packing list in the documents box in the front cabinet door of the equipment. In case of any problem, please contact us or the supplier. 1. Check if the information attached to the equipment is complete and in conformity with the content of packing list of the equipment. 2. Check if the nameplate on the cabinet body to confirm that the equipment is in line with the ordered equipment. 3. Check whether the spare parts and components are damaged or lost. The spare parts and components shall be governed by the procurement contract. (Note: make sure that the installation auxiliary of detachable starter shall be in accordance with the packing list)

Safety warnings
1. Be free from raff handling or installation and rain and be far away from the electromagnetic interference. 2. Prevent the children and the public from touching or approaching to this equipment. This equipment, with dangerous voltage, controls the dangerous rotary mechanism. 3. This equipment shall be only used for the purpose specified by the manufacturer; the unauthorized modification or the operation not conforming to the regulations of this manual will result in severe personal injury and other injuries. 4. Please read the installation operation and safety instructions of maintenance in this manual carefully before operating this equipment.

I. General
Large and medium side case style asynchronous motors are the main power equipment of many industrial and mining enterprises. According to the specification of state energy saving centre, high voltage motor shall be of the priority among large and medium side motors, whose starting is a primary problem in usage. In each industrial

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY
and mining enterprise of our country, the following starting modes are usually adopted for large power case motor: direct starting, starting with the reactor serially connected, high voltage frequency conversion soft starting and voltage reducing starting with liquid resistance serially connected and so on. When the motors directly connected to the electric network in full voltage start, reducing the voltage of the electric network will affect the normal operation of other equipment in the net and accident may even happen; the motor connected to the special transformer requires a certain spare capacity of the transformer. However, the spare capacity of the transformers in many enterprises is limited and only no-load full voltage starting can be done, and then the load will be added after starting, which gives a huge mechanical impact on the motor and shortens greatly the lifespan of the motor and the driving system. In this case, voltage reducing starting mode can be selected exclusively for the starting of the case motor. Star triangle decompression starting and draw-out triangle decompression starting modes do not need the special starting equipment. But the plugs of the stator winding of the motor are mostly demand complicated manufacturing technology, and the price of the motor is high. These two starting modes are seldom selected because of the limitation of the stator winding wiring mode of the motor. For resistance and reactor decompression starting, although the prices of the starting equipment are low, they are the washout products for their disadvantages of large starting current, unstable starting performance, unadjustable resistance value during the starting process, over heating, high energy consumption, uncontrollable starting process, inadvisable continuous starting and short lifespan. Heat-variable resistor utilizes the negative temperature characteristic of the liquid resistance to change the resistance value, but actually the characteristic of the liquid resistance that the resistance reduces with the increase of the temperature is quit limited, basically equivalent to a constant resistance. Though it can fulfill the function of starting for one time, its starting performance can not meet the requirement of the motor during starting that the resistance shall be reduced smoothly. And its control performance is poor with high temperature rise for one time starting, which is not suitable for constant starting. For this condition, our company developed the liquid resistance soft starting equipment for large and medium size case motor based on more than ten years experience of developing liquid resistance product. This product utilizes the features of large capacity and good adjusting performance of the liquid resistance to control the starting current of the motor within the range of 2 to 3.5 Ie times of the rated motor current, which greatly lower the starting current. It becomes the ideal soft starting product at present for large and medium size case motors because of its favorable starting performance in China. The resistance of WLQ series starter for high voltage case motor is the water solution compound by special transmitter substance, which connected serially in the stator loop of the motor. The resistance controls its value variety from big to small in the starting process of the motor, which accommodates to the starting performance of the asynchronous motor and significantly reduces the starting current of the motor, and thereby fulfills the decompression smooth starting without impact on the case motor.

II. Basic operation principle


According to motor driving theory, serially connect the liquid resistance compound by special transmitter substance with the functions of voltage division and current limiting in the motor stator loop. In the starting process, the resistance value of the resistance automatically fulfills the endless variety from big to small during the setting time period to make the terminal voltage on the motor stator and the starting torque gradually increase, when the rotation speed of the motor approaches the rated value, the liquid resistance will be cut off and the full-voltage operation will be input to realize the low current smoothly soft starting of the motor.

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY
III. Performance characteristic
1. Constant current soft starting: small starting current, which is 2 to 3.5 times of the rated current of the motor; 2. Smooth starting process, no impact, the decompression of the electric network is within 10%, and these ensure the reliable and safe operation of the electric network, protecting the motor and the driving machine efficiently, prolonging the lifespan of the equipment; 3. It can not be affected by the voltage pulsation of the electric network or the variety of the load, and can ensure the first starting is completed smoothly. It is capable of continuous starting for more than three times which is better than high voltage heat-variable resistor starter; 4. Possess perfect alarming indication function and function of protecting the motor; 5. Select PLC controlling, with easy and reliable structure and convenient maintenance; 6. WLQ4-3000 or super style product can adopt purpose made fairleader style which can make the starting current go through the liquid resistance smoothly and further reduce the temperature rise of the liquid resistance, and thus the starting performance is increased and meanwhile the using space is saved for the user because of the compact structure of the starter.

Liquid resistance tank

Liquid resistance tank

star wiring mode

triangle wiring mode

IV. Type naming


The naming method of WLQ serial starter for case motor is shown as follows:

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY

A type example: WLQ4-1000X/10C indicates the soft starter for case motor with design no. 4, the matching power 1000KW, the star wiring mode motor of voltage class 10KV, and PLC controlling. The main type selecting parameters of WLQ series high voltage case motor starter are the motor power, the rated voltage and the connecting mode of stator coil. The users shall determine the type of the starter according to the above naming method and the specific type classification in the main technical parameter of this manual on the basis of local mill motor power, the rated voltage and the wiring mode. In addition, the type of the load shall be notified when ordering.

V. Working conditions
Environment temperature: -40 to +50 Relative humidity: 90% Height above sea level: 2000m Installation place: no severe shake or impact vibration; no erosive gas or conductive dust; inclined angle of installation: <5; Requirement of the controlling power supply: three-phase four-line AC 380V10%, 50HZ,10A.

VI. The main technical parameter


1. Performance index The rated voltage (KV) 3, 6, 10; The highest voltage (KV) 3.5, 6.9, 11.5; One minute power frequency tolerance voltage (KV) 25, 30/32, 38/42 (phase to ground); One minute power frequency tolerance voltage (KV) 25, 30/32, 38/42 (interphase); (The above tolerance voltage does not include the liquid resistance tank); The starting current (A) Iq: 1.5 to 3.5Ie; The starting time (S) Ti: 10-60-120 (adjustable on site); Times of constantly starting: more than 3 times; The normal working temperature of the electrolyte (): 12/time; The below continuous curve shows the starting current of WLQ series starter and the broken line is for the direct starting:

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY

Current (A) Voltage of the electric network (V)

Voltage (V)

Current (A) Rotation speed (rpm)

2. Protection function In the peripheral of WLQ series starter, liquid resistance over temperature, liquid level trouble, driving over load, starting over time, over travel and external element operating trouble are written in the integrated protection program in PLC. External fixed interfaces are prepared for convenient technology protection of set driving, radiating system and primary fault by the users. Therefore, the motors of the user can fulfill the soft starting process safely and reliably. 3. Protection degree IP20 VII. Overall diagram and installation dimension There are integral type structure and divided type structure of WLQ series starter. When there is no special requirement from the user, integral type structure can be used for the motor of class voltage below 3000KV, well divided type for above 3000KV. The overall diagram and installation dimension for integral type starter is shown as follows:

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY

D A

E B

There are liquid cabinet and star-point cabinet of divided type starter, the overall diagram and installation dimension for star-point cabinet is shown as follows: Liquid resistance cabinet (phase A)
A

Star-point cabinet

Liquid resistance cabinet (phase B)


B

Liquid resistance cabinet (phase C)


C

A 4A+30

(1)Front view

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY

(2) Plan view of installation


Channel steel 100485.3 Note: 1. Connect the cabinets by crews. 1 2. Use wall bushing for the connection of the electrics among the cabinet. 2 Channel of primary cable (3) Side view Channel of secondary cable

Front Cabinet

Channel 10

Type WLQ4-3 WLQ4-380

Overall dimension(mm) A 1500 B 1300 C 2000

Installation dimension(mm) D 1450 E 1250

Remarks Single-side cabinet

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

C+40

EAGLE TECHNOLOGY
WLQ4-630 WLQ4-1000 WLQ4-1500 WLQ4-3000 WLQ4-4000 WLQ4-5000 WLQ4-6000 WLQ4-8000 WLQ4-12000 WLQ4-15000 WLQ4-20000 WLQ4-30000 WLQ4-40000 Note: The overall and installation dimensions will change due to constant upgrading of the product. Please refer to the particular product. specially designed according to the working condition of the motor 1500 1500 1800 1000 1110 1410 1410 1410 1300 1300 1300 1300 1500 1500 1500 1660 2200 2200 2000 2200 2200 2500 2400 2600 2700 2800 2800 2800 1450 1450 1750 1750 950 1060 1360 1360 1360 1460 1250 1250 1250 1250 1450 1450 1450 1610 2150 2150 Single-side cabinet Single-side cabinet Single-side cabinet Single-side cabinet four-side assembly cabinet four-side assembly cabinet four-side assembly cabinet four-side assembly cabinet four-side assembly cabinet four-side assembly cabinet

WLQ4--2000 1800

WLQ4-10000 1510

. Installation and commission


The installation and commission of WLQ series starter must be done under the guide of our technicians. Before actual commission, the user should get the equipment ready and fix them above the cable trench by the channel steel base. In addition, prepare the cables with required length and make the cable heads. 1. Connect the interlock control lines and the cables of the motor main loop according to the electrics schematic diagram and electrics interlock diagrams attached in this manual; 2. In the case of the main loop of the motor without power supply, power on the starter (note: the air switch QF1 inside the starter should be in open state first); 3. Close QF1, the electrode shall move toward the reset direction (the reverse direction of the stable electrode). If not, open QF1 immediately, and reversely connect (reverse phase) any of the two lines of the three-phase power supply lines. Reclose QF1, and the electrode should reset automatically. Check if the starting, operating and stopping state are normal; 4. Prepare the liquid resistance. First, calculate the required resistance value according to the motor parameter, the voltage and the load status; take three bags of the electrolytic powder, dissolve them by distilled water respectively, put them into three tanks; then respectively add distilled water until the water level in each tank is about 10cm below the tank cover. Measure if the liquid resistance value is the value the starter needs by the minitype transformer used for resistance measurement attached in the starter. (refer to the fourth term in the precautions when preparing the liquid); 5. According to the size of the motor and the status of the load to set the operation time of each time relay inside the starter; 6. Power on to test starting without load and stop for several times ( the main loop cant be power transmitted) to make the electrolytic powder dissolve away; 7. Power on the main loop and start the motor. If the starting current is between 2 and 3.5Ie, the commission of the starter is done and the starter can be put into usage. If the starting current is too large or starting cant be completed, adjust the density of the electrolyte (refer to the precautions part in this manual) and

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY
the starting time.

IX. Operation process


1. Starting up Close the air switch QF1 inside the starter, the reset indicator light of the starter is on and the electrode resets automatically. Starting allowable light is on after start-up. Switch on the isolating switch of the power supply of the motor main loop; The motor begins to start after the starting button is pressed, and the starting allowable light is off with starting light on. Switch to operating state after start-up and the starting light is off with operating light on. Stop The motor stops operating automatically after the stop button is pressed. The starter resets automatically right now; Switch off the isolating switch of the power supply of the motor main loop; Open QF1 inside the starter.

2.

X. Precautions
1. The starter cabinet of case motor must be grounded reliably; 2. The electrolyte is not allowed to be touched, the electrode and other charged parts, as well as the tank. Because the liquid inside the tank may be with high voltage after start-up; 3. Start the main motor only after starting allowable light is on. If starting allowable light is not on after the starter is reset, insepct the starter and adjust it to be normal before use the starter; 4. In the starting process, if the instant starting current is too large, lower the density of the electrolyte to increase the starting resistance; if the current after start-up is too large, increase the density of the electrolyte to ensure enough starting torque for the motor. When modifying the electrolyte density, do not splash the electrolyte on the tank edge, the surface or the cover to avoid electrical leakage or short-circuit. in case of unexpected splash, use a dry duster cloth to clean it immediately; 5. If it is necessary to stop starting or operating in case of abnormal circumstance in starting or motor operating process, stop button shall be pressed. If invalid, cut off the power supply ( switch off the air switch QF1) of the control loop immediately; 6. Cut off the power supply of the starter or switch off the air switch of the starter when normal operation of the host is prohibited; 7. Check if the tank is put right at the middle place, if the liquid level reaches the prescriptive height and if the electrode can move up and down freely before using the starter which has been idle for a period of time; 8. In case of powering on for the first time due to change in phase and frequency of the working power supply of the starter caused by equipment maintenance or other reasons, attention must be paid to the moving direction of the electrodes; 9. If the no-load test of Y type starter is normal, but the temperature of the liquid is too high or even boiling (vapor is given out from the tank) when the starter is operating, it is due to the poor connection of the star-point contactor of the motor. Stop and inspect without delay; 10. In case of special declaration (easy to freeze cold north area) when ordering, the starter will be matched with three heaters (the rated power of each heater is 1KW, working voltage is AC220V). The electrolyte of the starter may be freezing after stop for a period in cold winter. Before restart, use the heaters to heat first and

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

EAGLE TECHNOLOGY
then stop heating and take the heaters out after the ice is melted. At last, repower on the starter to enter the reset state.

XI. Basic maintenance


1. Check if the liquid level is too low periodically. The level shall not be 20cm below the tank cover. Meanwhile, the levels of the three tanks shall be kept the same, if not, add water in time; 2. Due to water quality, electrolyte volatilization and other reasons, the starting performance of the starter may not get better than before, such as large starting current or the motor cant reach the rated speed rotation after starting (that is, the motor cant be started). In these cases, it is necessary to add some water (for the former condition) or electrolytic powder (for the later condition) into the tanks; 3. For Y type starter, star-point contactor (also called short circuit contactor) of the main motor stator or the circuit breaker need to be checked regularly and make them pull-on well to ensure the safe usage of the starter and the safe operation of the main motor; 4. Each time overhauling the equipment, test the isolation starter for safety.

XII. Fault finding


The inspection and repair work shall be done by technicians or electricians when the starter is faulty. According to symptoms of the fault, the analysis, inspection and maintenance work shall be done with reference to the schematic diagrams attached in this manual. For convenient maintenance work, please take care of this manual. In case of any problem difficult to be solved, please contact our technology service department immediately. (Contact Tel: 0710-3405771 or 0710-3400558-8016). We will provide you with technology support at any time.

Eagle Technology
Address: No. 201, L-2, B-11, Surya City, Chandapura, Bangalore, India- 560081.
E-mail- eagleteam.in@hotmail.com , Phone No- +91-9535-122013, Website: http://eaglewanlida.com

Vous aimerez peut-être aussi