Reverse Osmosis System Analysis for FILMTEC Membranes Project: Solar Desalination XYZ, TRA International
Project Information: Case-specific: System Details Feed Flow to Stage 1 45.00 m/h Raw Water Flow to System 45.00 m/h Feed Pressure 65.04 bar Flow Factor 0.85 Chem. Dose (100% H2SO4) 0.00 mg/l Total Active Area 743.20 M Water Classification: Seawater (Open Intake) SDI < 5 Feed Flow (m/h) 45.00 Feed Press (bar) 64.69
Pass 1 Permeate Flow 15.00 m/h Pass 1 Recovery 33.33 % Feed Temperature 25.0 C Feed TDS 35000.01 mg/l Number of Elements 20 Average Pass 1 Flux 20.18 lmh
Osmotic Pressure: Feed Concentrate Average Average NDP Power Specific Energy Avg Flux (lmh) 20.18 Perm Press (bar) 0.00
27.57 42.05 34.81 29.16 101.64 6.78 Boost Press (bar) 0.00
Stage 1
Element SW30XHR-400i
#PV #Ele 4 5
Pass Streams (mg/l as Ion) Name NH4 K Na Mg Ca Sr Ba CO3 HCO3 NO3 Cl F SO4 SiO2 Boron CO2 TDS pH Feed 0.00 0.00 13768.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21231.88 0.00 0.00 0.00 0.00 0.00 35000.01 N/A Adjusted Feed 0.00 0.00 13768.12 0.00 0.00 0.00 0.00 0.00 0.00 0.00 21231.88 0.00 0.00 0.00 0.00 0.00 35000.01 N/A Concentrate Stage 1 0.00 0.00 20631.86 0.00 0.00 0.00 0.00 0.00 0.00 0.00 31816.50 0.00 0.00 0.00 0.00 0.00 52448.37 N/A Permeate Stage 1 Total 0.00 0.00 0.00 0.00 36.60 36.60 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 56.45 56.45 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 93.05 93.05 N/A N/A
Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customers use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.
15/03/11
Page 2 of 3
Reverse Osmosis System Analysis for FILMTEC Membranes Project: Solar Desalination XYZ, TRA International
Design Warnings -NoneSolubility Warnings -NoneStage Details Perm Flow (m/h) 0.95 0.85 0.75 0.65 0.55 Perm TDS (mg/l) 63.03 76.21 93.27 115.49 144.60 Feed Flow (m/h) 11.25 10.30 9.45 8.70 8.05 Feed TDS (mg/l) 35000.01 38233.14 41674.44 45255.41 48882.92
Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customers use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.
15/03/11