Indian Standard

1s 11537 - 1976 ( Reaffkmed 1996 )

SPECIFICATION FOR VERTICALLY CAST IRON PRESSURE PIPES FOR WATER, GAS AND SEWAGE

( First Revision)
Fourth Reprint APRIL 1997

UDC

621.643.2.986@69.13-140

BUREAU
MANAK

OF

INDIAN

STANDARDS
ZAFAR MARO

BHAVAN,

9 BAHADUR SHAH NEW DELHI 110002

Gr 5

March 1976

IS:153701976 (Reaffied 1996)

Indian Standard
SPECIFICATION FOR VERTICALLY CAST IRON PRESSURE PIPES FOR WATER, GAS AND SEWAGE

( First Revision)
Cast Iron and Malleable Cast Iron Sectional Committee, SMDC 9
Chairman Da PBANLAL PATEL
Members SHBI S. N. AC+BAWAL Repesenting

Malleable Iron & Steel Castings Co Pvt Ltd, Bombay

Electrosteel Castings Ltd, Calcutta SERI S. S. CHAWDHU~Y Alfernafc 1 ( Directorate General of Supplies 8i Disposals SEEI M. C. AFKIH ( Inspection Wing ), New Delhi International Nickel ( India ) Pvt Ltd, Bombay DR S. N. ANANTNABAIN Mining and Allied Machinery Corporation Ltd, SHRI M. ANJANEYULU Durgapur SH~I B. M. SENQUPTA Alternate ( ) National Test House, Calcutta Snn~ N. C. BAQOFII Directorate General of Technical Development SEBI R. M. BALANI of Industrial Development ), Ny;n;;;lyi

SH~I T. R. MOEAN RAO ( Alternofc ) Premier Automobiles Ltd ( Meehanite Foundry ), SERI B. N. BALI~A Bombay C H E P I s T & METALLURQIST, Ministry of Railways LOOOMOT~~E CEITTARANJAN WOIIKS,CHITTARANJAN ASSISTANT DIRECTOR MET ), ( INSP-II, RESEARCH, DESIQNS I(r STANDARDS ORQANIZATION, LUCKNOW Alternate ) ( New Precision ( India) Pvt Ltd, Dewas SHRIM. S. DESFIPANDE In personal capacity ( 167, Sector II-A, Chandigarh) SEBI M. S. DUA EXEOUTIVEENQINEEB, CENTRAL Central Public Works Department, New Delhi STOSES DIVISION No. 1 ( Continued on pge 2 )
@ Cojyright 1976

BUREAU OF INDIAN STANDARDS This publication is protected under the Indian Coprright Act (XIV of 1957) and reproduction in whole or in part by,_any means except with written permissionof the publisher shall be deemed to be in infringement of copyright under the said Act.

IS : 1537 - 1976 (Continued page1) from


Members Representing

SHnI SWARTJP GHOSH Srtn~GOVIND SINGE SEESK. V. GURRAM SHRI R. K. KAPOO~( Alterautc) SERI P. R. JALAN SEIUA. K. KAJARIA SHRI F. S. KATPITIA SERI M. R. SHAH( Alternate ) DB K. V. KBISHNAMUBTEY SHRItnV KU?dAn SHRI S, MAITRA SHRI K. K. MALLIOK SHIUM. P. MANIVANNAN

Indian Posts & Telegraphs Department, Calcutta Greysham & Co, Delhi Delhi Cloth & General Mills Co Ltd, New Delhi Hindusthan Malleables & Forgings Ltd, Dhanbad Engineering Export Promotion Council, Calcutta Jyoti Ltd, Baroda Hindustan Steel Ltd ( R&D ) , Ranchi Trade Development Authority, New Delhi Indian Smelting & Refining Co Ltd, Thana Ministry of Defence ( DGOF ) Cast&cztp Popes Manufacturers Association,

SHBIN. D. M~ANI Sree Engineering Products Ltd, Riihra SHRIB. MUKEZXJEE Burn & Co Ltd, Howrah SHRI S. K. MOULIK( Alternate ) SHRIP. MTJ~ARI Saltthi Pipes Ltd, Madras SH~I M. P. MANI~ANNAN Alternate 1 I . Pioneer Equipment Co Pvt Ltd, Baroda CDR K. N. NAP SHRIP. V. R. RAO (Alternate ) SHBI P. C. NEOUY Indian Iron & Steel Co Ltd. Calcutta SEIUK. S. LAL (Alternate) DR P. S. PATTIHAL Tata Engineering & Locomotive Co Ltd, Jamshedpur SHEIB. K. GIRI ( Alreraate ) SHRIA. K. POLEY Shiva Durga Iron Works (P) Ltd, Howrah SHRIB. K. DEER CHOWDHURY (Alternate) SHRI B. V. PRABHU Heavy Engineering Corporation Ltd, Foundry Forge Plant, Ranchi SHRIJ. S. TRIPATHI(Alternate) SHRIA:S. N. RAO Bharat Heavy Electricals Ltd, Tiruchirapalli SHRIA. SOMA~UNDRAM ( Alternate ) Co-ordinating Committee on Materials for AutoREPRESENTATIVE mobiles, SMDC 31, IS1 REPRESENTATIVE Hindustan Steel Ltd, Ranchi SHRIC. S. S. SETTY Ennore Foundries Ltd, Madras SHRIK. V. RAIKAKRISHNAN ( Alternate ) SHSI K. S., SHAH Institute of Indian Foundrymen, Calcutta SHRIA. GUHA ( Alternate ) SHRIAMOLAKH SHARDA S. R. M. Engineering Works, Ahmadabad
SHRI RAVINDARA R. Row ( Alternate ) SHRI P. J. SHENOY Kesoram Spun Pipes & Foundries, Calcutta SHRI R. R. JOSHI (Alternate) SHRIR. K. SINHA Fertilizer Corporation of India Ltd, Sindri SHRI S. G. TILLU Shah Malleable Castings Ltd, Tbana SHRI D. G. DODHIA ( Alternate) DR S. K. TIWARY National Metallurgical Laboratory ( CSIR ),

BestJ?%%?td DR P. VA~UD~VAN SHRIR. A. PANDURAN~A Alternate) (

. Madras

( Continued ~1 page 17 )

lS:1537-1976

Indian Standard
SPECIFICATION FOR VERTICAL&Y CAST IRON PRESSURE PIPES FOR WATER, GAS AND SEWAGE

( First Revision )
0. FOREWORD

0.1This Indian Standard ( First Revision ) was adopted by the Indian Standards Institution on 30 January 1976, after the draft finalized by the Cast Iron and Malleable Cast Iron Sectional Committee had been approved by the Structural and Metals Division Council.
0.2 This standard was first published in 1960. As a result of experience gained during these years, it has been decided to revise this standard incorporating the following modifications: a) Amendment No. 1 issued earlier has been incorporated, b) Appendices A and B have been deleted, and c) With the publication of IS : 7181-1974*, the notes beIow Tables 8 and 9 have been deleted. 0.3 This standard contains clauses which require the purchaser to specify his requirements, if necessary, while placing an orde,r. These clauses are 3.2, 6.1.2, 9.1.2 and 10.2. 0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS : 2-1960-j-. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.

main lines of water, gas and sewage manufactured sand moulds . sewage.
*Specifitiation for horizontally cast iron double

1. SCOPE 1.1This standard covers the requirements for cast iron pipes for pressure
by vertical

casting in

flanged pipes for

water, gas and

tRules for rounding

off numerical

values (revhd).

IS : 1537 1976 1.2 This standard is applicable to pipes with sockets ( for lead joints) or flanges. The standard may also be made applicable to other types of joints specialIy rubber joints, where overall measurements shall be adhered to, to ensure interchangeability. 2. SUPPLY OF MATERIAL 2.1 The general requirements
laid down in IS : 1387-1967. relating to the supply of material shall be as

3. MANUFACTURE 3.1 The metal used for the manufacture


than that of Grade 15 of IS : 210-1970i. of pipes shall be of quality not Icss

3.2 The pipes shall be stripped with all precautions necessary to avoid The pipes shall be free from defects, other warping or shrinking defects. than any unavoidable surface imperfections which result from the method of manufacture and which do not affect the use of the pipes. By abeement between the manufacturer and the purchaser, minor defects may be rectified. 3.3 The pipes shall be such that they could be cut, drilled or machined. In case of dispute, pipes may be accepted provided the hardness of the external unmachined surface does not exceed 210-B. 3.4 In the case of spigot and socket pipes for lead joints, without the centring ring. the socket shall be

3.5 In the case of flanged pipes, the flanges shall be at right angles to the axis of the pipe and machined on face. The bolt holes shall be drilled.

4. MECHANICAL TEST 4.0 Mechanical tests shall be carried out during manufacture of pipes after every 4-hourly intervals. The results so obtained shall be taken to represent all the pipes of different sizes manufactured during that period.
4.1 Tensile Test - Two tensile tests shall be conducted on bars cast from the same metal in accordance with IS : 2078-1962$. The results of the tests shall show a minimum tensile strength of 150 N/mm* ( 15 kgf/mms). 4.2 Hardness Test - If required, the Brine11 carried out in accordance with IS : 1789-1961s.
*General iMethod $Method

hardness

test shall

be

requirements for the supply of metallurgical materials (JFlst reuision). tSpecification for rey iron castings ( second rruision ).
for tens] * e testing of grey cast iron. f for Brine11 hardness teat for grey cast iron.

15:1537-1976 3. RE-TESTS 5.1If any test piece representing a lot fails to pass the test in the first instance, two additional tests shall be made on test pieces made from the same metal used for that lot. Should either of these additional test pieces fail to pass the test, the lot shall be liable for rejection.
6. HYDROSTATIC TEST 6.1 For hydrostatic tests, the pipes shall be kept under pressure for 15 They shall seconds; they may be struck moderately with a 700-g hammer. withstand the pressure test without showing any leakage, sweating or other As far as possible, the hydrostatic test shall be condefect of any kind. ducted before coating the pipes. 6.1.1 Vertically Table 1.
TABLE 1

cast pipes

shall withstand

the

pressure specified

in

HYDROSTATIC

TEST PRESSURE

FOR VERTICALLY

CAST PIPES

NOMINAL DIAMETER

~_____-----h__--_---_~ Socket and Spigot Pipes r------zT Class A B 2.5 ( 25) 25 ( 25 ) 2.0 ( 20 ) 1.5 ( 15)

TESTPRESSURE N/mm2 ( kgf/cmz) IN


Flanged Pipes --h___~ rClass Class A B

Up to and including

300 mm

2.0 ( 20) 2.0 (20 ) 1.5 ( 15) 1.0 ( 10)

2.0 (20)
15 (15) I.0 (10) 1.0 ( 10)

2.5 (25)
20 ( 20 ) 1.5 ( 15 ) 1.0 ( 10)

Over 300 mm and up to and including 600 mm Over 600 mm and up to and incIuding 1 000 mm Over 1000 mm to I 500 mm

6.1.2 When pipes are required for higher test pressures, the test pressures are subject to special agreement between the supplier and the purchaser.
7. SIZES

7.1The dimensions of pipes, sockets, spigots and flanges shall conform to


the sizes specified in Tables 2 to 8. 7.2 The pipes have been designated in accordance with the series adopted in IS : 1536-1976*, where pipes have been classified as LA, A and B according to their thickness. Class LA pipes have been taken as the basis for evolving the series of pipes. Class A allows a 10 percent increase in thickness over Class LA. Class B allows a 20 percent increase in thickness over Class LA, For vertically cast pipes, class LA has not been taken as standard. -.__~_.__--_ *Specification for centrifugally cast (spun) iron pressure pipes for water, gas ar .1

sewage ( second revision )

IS : 1537 - 1976
TABLE 2 DIMENSIONS OF SOCKETS AND SPIGOTS OF PIPES

( Ciauscs 7.1 and 9.1 )

__.-NOMINAL

-)
/-__- DI / mm
llb

--.I

IIAMETE~ 1 I CARREL DE (Dfl) ~mm mm ---q1:: 118 144 125 150 170 222 200 274 250 326 300 350 378 429 400 450 480 532 500 635 600 700 738 750 790 642 800 945 900 1048 1000 1 100 1 152 1 256 1 200 1 567 _ 1 5nn
*Dimensional minimum permissible

SOCKET
mm

P T* g

137 163 189 241 294 34G 398 449 501 553 657 760 813 865 968 1 072 1177 I 281 1 594
g and

8; 2
100

~- 225
mm

- h* _ mm
llou.5 11 12 1z.5 15.5 17 18 ii.5 z.5 27 ii.5 z.5 38 455

I_

BEAD -- DC 104 124 150 176 228 281 333 385 436 487 539 642 745 798 850 953 1 056 1 160 1 264 1 576
c -_

.T - ,nm
3 ;

mm .- -__

23

I-

JOINT
HICKNES: f mm

G-5 z.5 29 30.5 32 :ii 38 41. 425 44 47 2: 2;

103 105 107 110 112 115 120 122 123 125 128 130 135 140 150 h clo
not

3 3 3.5 3.5 3.5 33:; 3.5 33:; 3 : 4 4 45


they only

E.5 9.5 9.5 95 10 10 10 :: 10.5 11 11 115 115 I 1 n.5 12 12.5 12 5 13.5


indicate

.~

figures

affect

interchangeability;

thicknesses.

IS : 1537- 1976
TABLE 3 DIMENSIONS OF SOCKETS OF ( For Information Only ) ( Clauses 7.1 and 9.1 ) FITTINGS

Fittings (collars expected

Collars

I-

NOMINAL DIAMETEB CDN) mm 1:: 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1 100 1 200 1 500

SOCIZET

UI 116 137 163 189 241 294 346 398 449 501 553 %t!l 813 865 968 1072 1 177 1281 1 594

P mm ilQ 91 1:: 103 105 107 110 112 115 120 122 123 125 128 130 135 140 150

g*
23 zi.5 25.5 27 3209.5 32.5 34 36 37.5 41 44.5 46 48 51.5 55 58.5 62 72.5 alfrcting

mm 12 125 13 14

ii
16.5 17.5 19 20 21 22.5 25 27.5 29

iifl

32.5 35 37.5 40 47.5

*Dimensional figures ,q and k are not measurcrucnts otll>- indicate minimum pcrmissiblc thickurssrs. _c... ._ p-n.

interchangeability;

IS : 1537- 1976
TABLE

DIMENSIONS

OF FLANGES

OF PIPES AND FITTINGS b = 19 + 0.020 DN _s 10'5 0.03 DN = +

-____

NOMINAL DIAMETER

D
mm

n mm

b
InIn

iDN\
mm

125 150 200 250 300 350 500 600 700 750

Iio

220 250 285 340 395 445 505 565 615 670 780 895 960 015 5 $0 340 455 OUO

200

44.5 47 52 57 61 G6 51 :; !,O 1II0 10.5 110 120 130 140 150 1uo

z:
22.5

mm

13 135 14.5 11Z.5 18 19.5 21 22.5 24.0 25.5 28.5 :k5 34-5 37.5 40.5 43.5 46.5 555

z.5 22f.5 :z 31.5 33 36 38.5 40 41.5 44 5: 53 61

mm 6 6 6 6 : : 10 10 10 12 12

foO

12
12 15

IS : 1537 - 1976
TABLE 5 STANDARD FLANGE DRILLING PIPES AND FITTINGS ( Clauses 7.1 and 9.1 ) No. OF
EOUALLY HOLES = A SPACED7

OF FLANGED

Holes drilled off centres unless-otherwise specified.

NOMINAL DIAMETER DJV ~____ mm ~__ _.~ 1% 125 150 200 250 300 350 400 500 450 700 600 750 800 900 1 000 1 100 1 200 1 500

D mm 200 220 250 285 340 395 ,445 505 565 670 615 895 780 960 1015 1 115 I 230 1 340 1 455 800

c mm f:8 210 240 295 350 400 460 515 620 565 840 725 900 950 1 050 1 160 1 270 1 380 710

HOLES Number A Diameter d mm tz 19 :: ;: 23 ;:

DIAMETER OF BOLTS

-_- mm
:6 16 ;: 20 10 z: ;a

8 8 8 12 ;:

16 2: 29 ;: 28

31 :; 31 ;: 37

2: z;: z: :z 39

z :;

!,: 43

Is : 1537 - 1976 <


TABLE

SOCKET

AND SPIGOT

PIPES -

CLASS

( Clauses 7.1 and 9.11

p&_(7+0*02DN)
12

TOTAL MASS IIOR ONE WORKING

LENQTH 1 IN MEDCEB

:ii 500 600 :: 800 000 100 200 500

429 % 635 738 790 842 945 1048 1 152 1256 1567

138 :::i 17.4 20.2 19.3 21.1 22.9 24.8 26.6 28.4 33.9

128.7 1560 181.0 241.4 348-Y 3116 389.1 474.3 5700 672.4 783.1 1 222.1

46.3 56.0 66.0 89.3 1168 131.7 147.8 182.6

900

517 627 728 973 1 257 409 1 568 1917

561 680 790 055 1 363 1 527 I 704 2080

674 817 949

690 836 971

914 754 1 061 1 417 2 051 1 830 2 288

1-

267
-

: 2;:
1 876 2093

_..

ts:1537-1976
TABLE 7 SOCKET AND SPIGOT PIPES CLASS B

( Clauses 7.1 and 9.1)

e = 7 + 0.02 DN

NOMINAL

BARREL

DIAMETER (DJV) _~_~_ mm 1:: 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1 000 1 100 1 200 1 _I_ 500

DE

e mm -I?%9-o 95 10.0 11.0 12.0 13-o 140 150 160 17-o 190 21.0 22.0 23.0 250 27.0 29.0 31.0 37.0 --

i for One
Metre Approx (-__ kg 17.3 22.0 28.7 35.9 52.1 70.6 91.4 114.5 139.5 IWO 196.7 ~~;~; 380.6 4231 516.6 619.2 739,o

Mass

, _ 300K~T
MASS ( APPROX )

TOTAL

MASSBOX ONEWORICINQ LENQTH LIN METRES 4 4.88 _5 kg 1:: 153 191 278 376 487 610 744 901 1 026 1 404 1 808 2 035 2 263 2 766 2 318 3 923 4 578 I 167 ______ 5.5 -~ kg 128 167 209 304 411 533 667 814 986 1 148 1 535 1 977 2 225 2 475 3 024 3 628 4 326 4 993 7 833

366

_ mm

98 118 144 170 222 274 326 378 429 480 532 635 738 790 842 945 1 048 I I 1 152 I 256 I 1567

)_ _- kg

5.5

..- kg

_-

9:; 11.5 16.8 22.9 29.8 375 463 560 660 893 116.8 131.7 147.8 182.6 222.3 2656 313.2 501.1

1 Kf;

11

1 1 1 1 2 2 2 3 5

69 88 114 143 207 281 364 457 557 675 786 052 355 525 696 073 489 970 430 3Rrl -

kg_ 74.5

1:: 155 225 305 395 495 604 732 853 1I 141 1 470 I 1 644 L I1840 ! 249 ! 699 I192 I 725 ;i 834

kg 271 368 476 596 727 881 1 026 1 372 -

IS:1537- 1976
TABLE 8 FLANGED PIPES, SAND CAST - CLASS A (Clauses 7.1 and 9.1 )

G--$

(7+0*02DN)

NOMINAL

i -.
DE

BARREL
e.

FLANGE
Mass for One Metre I Approx) Mass for One Flange

DIAMETRE (DJY)
mm 1;: 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1 000 1 100 1 200 1 500 *Depending

WORKING LENOTH' 1
m to 3 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to 4 to.4 to 4 to 4 to 4 to 4

-- __ mm _-_
178 144 170 222 274 326 378 429 480 532 635 738 790 842 915 1048 1 152 1 256 1 567 on manufacturers

mm 7.9 8.3 8.7 1o.T 11.0 119 12.8 138 14.7 156 174 193 20.2 21.1 22.9 24.8 26.6 28.4 33.9 facilities.

kg --___16.0 20.5 26.4 33,2 481 650 84.0 105.0 1287 156.0 1810 2414 3116 3489 389.1 474.3 570.0 672.4 783.1 1 222.1

(APP~o~) k --

3.7 4.2 5.3

9:; 12.0 14.8 19.0 23.4 26.5 32.1 44.0 59.9 69.8 80.8 946 120.0 139.0 173.0 276.2

- --

2 2 2 2 2 2 2 2 2 2 2 2 2 a 2 2 2 2 2 2

12

IS I 1537 1976 7.2.1For special uses, Classes C, D, E, etc, may be derived after allowing corresponding increases of thickness of 30, 40, 50 percent, etc, over Class LA.
8. TOLERANCES 8.1 Tolerances dn the External Diameter of the Barrel the Internal Diameter of the Socket and the Depth of the Socket - The tolerances shall be as follows: Dimension External diameter barrel ( DE) Internal diameter socket ( DI) of of .Nominal Diameter (DN) All diameters All diameters Tolerance mm

Depth

of socket (P)

[ Up to and including 600 mm 1 Over 600 mm and up to and including 1 000 mm Over 1000 mm and up to and including 1 500 mm 1 space
diameter

where f is the 9 + 0.003 DN.


NOTE -The of the pipe.

caulking
nominal

of the joint

in millimetres
denoting

and is equal to
bore

is the diameter

the approximate

8.1.1 The maximum tolerances is such .that affected.

or minimum jointing space resulting from these the jointing of the pipes and fittings is not adversely

8.2 Tolerances on Thickness - The tolerances flange thickness of pipes shall be as follows: Dimension Wall thickness Flange where e = the thickness 6 = the thickness thickness

on the wall-thickness Tolerance -y?+ f 005 e)*

and

(2 + 005 b )

of the wall in millimetres, of the flange in milhmetres.


is specified.

and

*No limit for the plus tolerances

13

Is : 1537- 1976 8.3 Tolerances on Length - The tolerances manufactured shall be as follows: Tyke of Casting Socket and spigot, and plainended pipes Flanged pipes on lengths of pipes normally Tolerance ZO -3: 10

Of the total number of socket and spigot pipes to be supplied in each diameter, the manufacturer may supply up to 10 percent in lengths shorter than the specified lengths as follows: Decrease in Length, SpcGifiGdLength, m m Upro4 05, I o-5, 1, i.5, 2 Over 4 8.4 Permissible Deviation from a Straight Line - The pipes shall be straight. When rolled along two gantries separated by approximately twothirds the lengths of the pipe to be checked, the maximum deviation fm, in millimetres, should not be greater than 125 times the length 1 in metres of this pipe, thus fm < 1251. 9. MASS 9.1 The standard masses are those as given in Tables 2 to 9. The masses have been calculated for each of the lengths generally used by taking into account in each case the mass of socket or flanged fixed arbitrarily as a proportion of the mass of the pipe barrel. For this purpose the density of cast iron has been taken as 715 kg/dm ( see Table 9 ). f 9.1.1 The 5 percent. permissible tolerances on standard mass of pipes shall be

9.1.2 If mutually agreed upon, the pipes of heavier mass than the maximum may be accepted, provided they comply in every other respect with the requirements of this standard. 10. COATING 10.0 After inspection and given under 10.1 to 10.6. hydrostatic test, each pipe shall be coated as

10.1 Coating shall n& be applied dry and free from, rust, . --,...

to any

pipe unless

its surface

is clears

14

IS : 1537 la76 lo.2 Except when otherwise agreed to between the manufacturer and the purchaser, all pipes shall be coated externally and internally with the same material, the pipes being heated prior to total immersion in a bath containing a uniformly heated composition having a tar or other suitable base.
10.3 The coating material shall set rapidly with good adherence and shall not scale off.
TABLE d= 9 FLANGED PIPES, SAND CAST -

CLASS B

(Clause ) 9.1 7 $0'02 DN

t-

----t

NOMINAL DIAMETER (Dfl)

BARREL DE e mm 8.6 90 95 100 11.0 120 13.0 140 15.0 16.0 17.0 190 21.0 220 23.0 25.6 27.0 29.0 31.0 37.0 facilities. --

FLANGE Mass for One Metre ( Approx ) kg 17.3 22.0 2@7 359 521 706 914 114.5 1395 1690 196.7 262.9 3382 380.6 423.1 5166 619.2 739.0 851.6 1 333.1 Mass for One Flange ( Approx ) kg ~. ~~_~.~ 3.7 4.2 5.3 67 9.3 12.0 148 190 23.4 265 321 440 59.9 69.8 80.8 94.6 120.0 139.0 1730 276.2

WORKINQ LENGTH* 1

1.

mm _~~ ~-- mm 80 98 100 118 125 144 150 170 200 222 250 274 300 326 350 378 400 429 450 480 500 532 600 635 700 738 750 790 800 a42 900 945 1 000 I 048 1 100 1 152 1 200 1 256 1 500 1 567 ~~ ~_..~_. *Depending on manufacturers

2t: 2 to 2 to 2to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to 2 to

3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

il:: 4

IS : 1537 - 1M6 10.4 In all instances where the coating material has a tar or similar base, it shall be smooth and tenacious and hard enough not to flow when exposed to a temperature of 77C but not so brittle at a temperature of 0C as to chip off when scribed lightly with a penknife.
10.5 When the pipes are to be used for conveying potable water, the inside coating shall not contain any constituent soluble in water or any ingredient which could impart any taste or odour whatsoever to the potable water after sterilization and suitable washing of the mains. 10.6 In the case of pipes (wholly or partially coated ) which are imperfectly coated or where the coating does not set or conform to the quality specified above, the coating shall be removed and the pipes re-coated.

11. MARKING 11.1 Each pipe shall have cast, stamped following appropriate marks:
a) Manufacturers b) The nomina1 diameter; c) Class reference; d) Mass of pipe; e) The number of this Indian Standard; and f) The last two digits of the year of manufacture. 11.2 Marking may be. done on the outsides of the sockets or towards the ends of the barrels of pipes. 11.3 Any other marks required by the purchaser may be painted on. 11.4 BIS Certification or indelibly painted mark; on it the

name, initials or identification

Marking

Ge product may also be marked with Standard Mark.


11.4.1 The use of the Standard Mark is governed by the provisions of the Bureau of Indian Standards Act, 1986 and the Rules and Regulations made thereunder. The details of conditions under which the licence for the use of Standard Mark may be granted to manufacturers or producers may be obtained from the Bureau of Indian Standards.

16

IS : 1537 - 1976
( Continued from page 2 ) Members SIUU H. VXNOD SHRI C. R. RAMA RAO, Director ( Strut & Met) R+resen t ing Oil and Natural Gas Commission, Dehra Dun Director General, IS1 ( Ex-o&cio Member )

Secretary Saar &ANTI SWARUP pssistant Director ( Metals ), ISI

Cast Iron Pipes and Fittings Subcommittee,


Conuener SHRI J. N. Roy Members

SMDC 9 : 1

Indian Iron & Steel Co Ltd, Kulti

SHRI S. N. A~SAWAL Electrosteel Castings Ltd, Calcutta SHRI S. S. CHOWDHURY ( Allernatc ) SHRI A. CHATTERJEE Orient Trading Co, Calcutta Bharat Valves & Engineering Co, Calcutta SHRI S. K. DAS SERI DE~H RAJ GUPTA National Metal Craft, Delhi S~tir D. K. HADA Indo-Swedish Pipe Manufacturers Ltd, Agra SHRI R. C. MAHESHWARI ( Alternate ) SHRI MALLI NATE JAIN Municipal Corporation of Delhi SHRI M. P. MAN~VANNAN Sakthi Pipes Ltd, Madras SHRI P. MURARI ( Altermite) SRRI J. S. NAPXTRAY Ministry of Irrigation & Power SHRI INDEBJIT SHARBIA ( Alternate ) SRRI B. B. RAU Ministry of Works 8~ Housing SHRI P. J. SHENOY Kesoram Spun Pipes and Foundries, Calcutta SHRI R. R. JOSHI (Alternate ) SUPERINTENDINQ SURVEYOR OF Central Public Works Department, New Delhi WORKS (DELHI A~aa ZONE), NEW DELRI SURVEYOR OF WORKS-II ( SOUTH WESTERN ZONE ), BOMBAY (Alternate )

17

BUREAU

OF INDIAN STANDARDS

Headquarters Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 Telephones: 323 0131,323 3375,323 9402 Fax : 91 11 3234062,91 11 3239399, 91 11 3239382 Telegrams : Manaksanstha (Common to all Offices) Central Laboratory : Telephone Plot No. 20/9, Site IV, Sahibabad Industrial Area, Sahibabad 201010 Regional Central Offices: 323 76 17 337 86 62 60 38 43 235 23 15 832 92 95 8-77 00 32

: Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002 *Eastern : l/l 4 CIT Scheme VII M, V.I.P. Road, Manik-tola, CALCUlTA 700054
Northern : SC0 335-336, Sector 34-A, CHANDIGARH Southern 160022

: C.I.T. Campus, IV Cross Road, CHENNAI 800113

twestern : Manakalaya, E9, Behind Marol Telephone Exchange, Andheri (East), MUMBAI 400093 Branch Offices:: Pushpak, Nurmohamed Shaikh Marg, Khanpur, AHMEDABAD SPeenya Industrial Area, 1 st Stage, Bangalore-Tumkur BANGALORE 560058 Road, 380001

550 1348 839 49 55 55 40 21 40 36 27 21 01 41 8-28 88 01 8-71 19 96

Gangotri Complex, 5th Floor, Bhadbhada Road, T.T. Nagar, BHOPAL 462003 Plot No. 62-63, Unit VI, Ganga Nagar, BHUBANESHWAR Kalaikathir Buildings, 670 Avinashi Road, COIMBATORE Plot No. 43, Sector 16 A, Mathura Road, FARIDABAD Savitri Complex, 116 G.T. Road, GHAZIABAD 201001 781003 500001 751001 641037

121001

53/5 Ward No.29, R.G. Barua Road, 5th By-lane, GUWAHATI

54 11 37 20 10 83 37 29 25 21 68 76

5-8-56C, L.N. .Gupta Marg, Nampally Station Road, HYDERABAD E-52, Chitaranjan Marg, C-Scheme, JAIPUR 302001 117/418 B, Sarvodaya Nagar, KANPUR 208005 Seth Bhawan, 2nd Floor, Behind LUCKNOW 226001 Leela Cinema, Naval

Kishore

Road,

23 89 23 52 51 71 26 23 05 32 36 35 621 17

NIT Building, Second Floor, Gokulpat Market, NAGPUR 440010 Patliputra Industrial Estate, PATNA 800013 Institution of Engineers (India) Building 1332 Shivaji Nagar, PUNE 411005 T.C. No. 14/l 421, University P. 0. Palayam, THIRWANANTHAPURAM 695034

*Sales Office is at 5 Chowringhee Approach, P.O. Princep Street, CALCUTTA 700072 tSales Office is at Novelty Chambers, Grant Road, MUMBAI 400007 *Sales Office is at F Block, Unity Building, Narashimaraja Square, BANGALORE 560002

271085 309 65 28 222 39 71

Printed at Dee Kay Printers, New Delhi, India

IS:1537-1976

PRESSURE PIPES FOR WATER, 6AS AND SEUAGF

SPECIFIC&lION FOR VERTICAUYCAST IRON

AMENDMENT NO. 1

JULY 1977

Alterations _--w-m (Pap 4, clause 3.3, '210 Ij[8' for '210-B'. (Page 10, T&k @llO',
tine 31 -

Substitute

6, co1 II - Substitute '100' fm OCTOBER 1978

AMENDMENT NO. 2

Alteration --m--w (Page 14, clcruse6.1.2) - Substitute the folloving for the existing clause: '9.1.2 The pipes of the heavier IWMS than the maximum shall.be a&eyted, provided they comply In every other respect with the requirements of this staridard.' AMENDMENT NO. 3 MARCH 1980 Addenda ----

(~crg~ 8, ebk
at the end:

41

- Add the follouing nev note

ImE - The dimensions a, f and 8 generally do not sifect the interchangeabilityand are for guidamX only.'

(P-ClausCS

II, czaue 8.4) - Add the following nev ,tt.r 0.4:

8.5 Tolerances for the rarious dimension8 of flanges not specified above shall be a8 follovr:

Datcri~titm
D (as cast)

Siau, DB mm

Tobawmt ma

Up to 250 Above 250

+3.0 -1.0 +5.0 -1.5 +1.0 +1.5 +2 -0 +3 -0

c
d

Up to 250 Above 250 up to 300 Above 300

8.6 Tolerances specified above 'Deviations for &stings (first

for dimensions other than those shall be as given in X:5519-1979 untoleranced dimensions of grey iron
reoiuim)
.

AMENDnENT NO.

4 MARCH 1983 Alteration _---Zl.Z(e)l - ndete*

[PW~? 26, dtwm mix 9)

NO. 5 MAY 1994 TO IS 1537 : 1976 SPECIFICATION FOR VERTICALLY CAST ,IRON PRESSURE PIPES WATER, GAS AND SEWAGE ( First
( Anrenndmenr No. 3, pge Revision )

AMENDMENT

FOR

2, clcluse 8.6 ) -

Substitute

the following only.

for the

existing clause: 8.6 lintolemnccd dimensiom g~vcn in the standard arc for guidance

(MID6)
Printed at Dee Kay Printers, New Delhi, India

Vous aimerez peut-être aussi