Vous êtes sur la page 1sur 2

1.

Need help with RBS 6000 SWAP

Originally Posted by mark009

Hi, first of all thanks all of u for ur response. yaqoob here are the aswers: -> Yes we are going to use E1. -> No, I have no experience in 3G or 3000 series. -> Yes, we are going to use same 2g E1's....Minilink TN is currently used and we will just swap the BTSs. -> Most probably RBS 6201/6201V2. -> E1. -> no, i dont.

6201 RUW for 3G. also, i think maybe you are going to use first carrier because you have limit E1 (2,3,4). Whoever, i will describe what are going to do step by step: A) 2G: just remove the power from the cabinet. B) 3G: you need the following cable to connect RBS6201 1. from port LTM A in the rbs use LAN-Serial then serial-USB (if your laptop doesn't have serial port -9 pins). the pins assignment has attached. Note: any serial cable has number of com 2. From port LMT B in the rbs use Direct LAN. 3. use RBS element manager software [Only registered and activated users can see links. ] to integrate RBS6201 4. config your local area connection, Internet Protocol (tcp\ip) as follows: ip address: 169.254.1.2 subnet mask:255.255.255.248 Default Gatway: 169.254.1.1 5. check your cabinet if it is used before or not by Hyper Terminal or [Only registered and activated users can see links. ] config the Hyper terminal using the com as attached file. for Putty just give the com number. inside the hyper terminal or putty write: $ifconfig for new cabinet: default IP is 169.254.1.1 otherwise this cabinet has used before. if we have default ip go to step 7 if this cabinet has different ip go to step 6 6. format the cabinet by using hyper terminal or putty comment. see [Only registered and activated users can see links. ] or [Only registered and activated users can see links. ] 7. connect all E1 to RBS 8. open the RBS element manager by default ip 169.354.1.1 9. from tools, export and delete. select only delete then ok 10. start install Cabinet script manually as follow steps: tools, cabinet Equipment configuration, next write the product no., series no., Date and Rev for 6201 cabinet select 3 sectors, Ext22, Ext. 2 finish. the cabinet will restart automatic 11. re-enter the rbs element manager and go to tools select O&M Access

configuration. select the O&M script path that's you have collected from Ericsson. Chose Automatic than next. the rbs will restart automatic 12. now go to tools again, chose the site equipment configuration add the file path for site script that you have collected from ericsson. chose automatic then next. 13. ping the RNC. file has attached Note: for RBS6000 don't change the local area connection. for rbs 3000 you have to change after install O&M script. Now your site should be remote for RNC to start update the Node. thanks.
Attached Files

o o
views)

RBS6000 DU Serial Connection Cable.rar (51.8 KB, 10 views) RBS_Initial_SW_Installation_Instruction[1].rar (193.5 KB, 10

3G Node-B Integration1.7z (469.4 KB, 23 views)