Vous êtes sur la page 1sur 1

ANNEXURE-1

SYSTEM CONTROLS & SWITCHGEARS


30 /30, Ground Floor, East Patel Nagar New Delhi - 110008 , India Ph:+91-011-45631920(100 lines),25711920.25737119,Fax: +91-011-45631903 TIN NO : 07580043512 RC NO : LC/44/043512/0183

RE 1462 DT :03-02-2012
To,

Three 'C' Universal Developers Pvt. Ltd. 3GF, Sundaram Complex RDC Raj Nagar, Ghaziabad, U.P.
KA : MR. SANJEEV SINGH Please refer to the details below to release the advance payment

CONSIGNEE:

Three 'C' Universal Developers Pvt. Ltd. Lotus Panache, Sector -110 Noida. UP

S.NO
1

DESCRIPTION Supply of ABB Make Distribution Boards


Type B ( Lighting DB) 8 way TPN DB, 24 No.10/16/20 Amps SP MCBs, 3 No. 63 A DP RCCBs of 100 mA leakage current and 3 No. 63A DP MCB 1No. 63 Amps 4 pole MCB as incomer with separate neutral link for each phase. Type C ( Lighting DB) 6 way TPN DB, 18 No.10/16/20 Amps SP MCBs, 3 No. 63 A DP RCCBs of 100 mA leakage current and 3 No. 63A DP MCB 1No. 63 Amps 4 pole MCB as incomer with separate neutral link for each phase. Type D ( Power DB) 4 way TPN DB, 12 No.10/16/20 Amps SP MCBs, 3 No. 63 A DP RCCBs of 30 mA leakage current and 3 No. 63A DP MCB 1No. 63 Amps 4 pole MCB as incomer with separate neutral link for each phase. Type C (For External Landscape lighting) Incomer 63 Amps 4 pole MCB incomer Outgoing 2 Set of 63 Amps 4 pole MCB with 70 Amps TP contactor 0-24 hours timer auto / manual by pass selector switches including 24 No. 16 Amps SP MCB Type D (Emergency DB) 6 way SPN DB with 8 Nos. 10 amps SP MCB as outgoing and 1 nos. 25 amps DP RCCBs of 30mA leakage current with separate neutral link for

QTY
8

UNITS
Sets

UNIT RATE
10,250.00

TOTAL AMOUNT
82,000.00

TOTAL AMOUNT

16

Sets

10,000.00

160,000.00

Sets

9,500.00

76,000.00

Sets

45,000.00

90,000.00

17

Sets

3,000.00

51,000.00

Supply, installation, testing and commissioning of 63 Amps 4 pole MCB in 1.6 mm thick MS enclosure of approved make design and painted with approved paint shade. Type A (Lighting DB) 6 way TPN DB, 18 No.10 Amps SP MCBs as outgoing with 3 No. 40 A DP RCCBs of 30 mA leakage current and 1No. 40 Amps 4 pole MCB as incomer with separate neutral link for each phase.

Sets

900.00

1,800.00

3.1

Sets

9,100.00

18,200.00

500,100.00

3.2

Type C (Lighting DB) 12 way SPN DB, 12 No. 10 Amps SP MCB as outgoing with 1 No. 40 Amps DP RCCB's of 30 mA leakage current as incoming including neutral link as incomer. Type D (Power DB) 4 way TPN DB, 12 No.10 Amps SP MCBs as outgoing with 3 No. 40 A DP RCCBs of 30 mA leakage current and 1No. 40 Amps 4 pole MCB as incomer with separate neutral link for each phase.

Sets

3,900.00

3,900.00

3.3

Sets

8,600.00

17,200.00

CST @ 2% EXTRA TOTAL AMOUNT

10,002.00 510,102.00

FOR SYSTEM CONTROLS & SWITCHGEARS

AUTHORIZED SIGNATORY TEMRS & CONDITIONS

1. OUR RESPONSIBILITY CEASES WHEN THE DELIVERY MENTIONED IN THE BILL HAS BEEN EFFECTED TO THE BUYER . 2. GOODS ONCE SOLD SHALL NOT BE TAKEN BACK IN ANY ACCOUNT. 3. IF AT ANY TIME DECLERATION FORM ISSUED BY YOU IS NOT ACCEPTED BY S.T. AUTHORITIES IN RESPECT TO THE ARTICLES SUPPLIED AND BILLED, A SUPPLEMENTARY BILL FOR THE FULL AMOUNT OF SALES TAX WILL BE RAISED. 4. ALL DISPUTES SUBJECT TO DELHI JURISDICTION 5. PLEASE PAY BE ACCOUNT PAYEE CHEQUE ONLY 6. INTEREST @ 18% WILL BE CHARGED ON THE OVERDUE PAYMENTS