QO Load Centers

Three PhaseMain Lugs, Main Circuit Breaker


Class 1130

www.SquareD.com
For the most up-to-date information

Max.
Number
of 1-pole
QO
Breakers

Total Price
(Interior,
Box and
Cover)

Indoor Cover with Door


(Order Separately)

Load Center
Box and Interior
Catalog Number

Price

Flush
Catalog No.

Surface
Catalog No.

Main
Wire Size
AWG/kcmil
Price

Equipment
Ground Bar Kit
(Order Separately)

Box No.
See
Pages
1-12, 1-13

#106

PK4GTA

$ 7.20

13

#62/0

#62/0

Factory-incl.g
Factory-incl.g
Factory-incl.g

...
...
...

6
7
7

LOAD CENTERS

Mains
Rating
(A)

(Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 6-10 and 6-11.)
3 Phase 4 Wire 208Y/120 Vac, 3 Phase 4 Wire 240/120 Vac Delta and 3 Phase 3 Wire 240 Vac DeltaUL Listed.

#6250

#6250

Factory-incl.f

...

9
9

Three Phase

Al

Cu

Catalog No.

Priceu

Fixed MainsFactory-installed Main LugsCopper Bus65,000 RMS Symmetrical Amperes Short Circuit Current Rating a
60

125

12
20
24

246.10
339.10
385.10

71.00

QO403L60NF/S
QO312L125G
QO320L125G
QO324L125G

221.00
314.00
360.00

71.00

QOC16UF
QOC24UF
QOC24UF

Cover Included With Load Center


QOC16US
QOC24US
QOC24US

$ 25.10 u
25.10 u
25.10 u

...

200

18

353.00

QO318L200G

295.00

QOC30UF

QOC30US

58.00 u

30
471.00 QO330L200G
413.00
QOC30UF
QOC30US
58.00 u
Factory-incl.f
...
I
225
42
635.00 QO342L225G
561.00
QOC42UF
QOC42US
74.00 u
#6300
#6300
Factory-incl.f
...
N
D
Convertible
MainsFactory-installed
QDL
Main
Circuit
BreakerCopper
Bus25,000
RMS
Symmetrical
Amperes
Maximum
O
O Short Circuit Current Rating b
100
27
$ 705.00 QO327M100 c
$ 647.00
QOC30UF
QOC30US
$ 58.00 u
#42/0
#42/0
PK15GTA
$11.40
R

11

125

30

1287.00

QO330MQ125 d

1226.00

QOC342MQF

QOC342MQS

61.00

#4300

#4300

PK18GTA

12.50

12

150

30
42

1287.00
1412.00

QO330MQ150 d
QO342MQ150 d

1226.00
1351.00

QOC342MQF
QOC342MQF

QOC342MQS
QOC342MQS

61.00
61.00

#4300

#4300

PK18GTA
PK23GTA

12.50
14.20

12
12

200

30
42

1287.00
1412.00

QO330MQ200 d
QO342MQ200 d

1226.00
1351.00

QOC342MQF
QOC342MQF

QOC342MQS
QOC342MQS

61.00
61.00

#4300

#4300

PK18GTA
PK23GTA

12.50
14.20

12
12

225

42

1412.00

QO342MQ225 d

1351.00

QOC342MQF

QOC342MQS

61.00

#4300

#4300

PK23GTA

14.20

12

Fixed MainsFactory-installed Main LugsCopper Bus65,000 RMS Symmetrical Amperes Short Circuit Current Rating a e
60

$ 118.00

125

12
20

323.00
419.00

QO403L60NRB
QO312L125GRB
QO320L125GRB

$ 118.00
323.00
419.00

...

#106

PK4GTA

#62/0

#62/0

Factory Incl.g
Factory Incl.g

$ 7.20

10R

...
...

3R
4R

Cover Included
R
18
412.00 QO318L200GRB
412.00
Factory Incl.f
...
200
#6250
#6250
A
30
559.00 QO330L200GRB
559.00
Factory Incl.f
...
I
225
42
996.00 QO342L225GRB
996.00
#6300
#6300
Factory Incl.f
...
N
P Convertible MainsFactory-installed QDL Main Circuit BreakerCopper Bus25,000 RMS Symmetrical Amperes Maximum
R Short Circuit Current Rating b e
O
100
27
$ 790.00 QO327M100RB c
$ 790.00
#42/0
#42/0
PK15GTA
$11.40
O
125
30
1431.00
QO330MQ125RB
d
1431.00
#4300
#4300
PK18GTA
12.50
F
150

30

1431.00 QO330MQ150RB d

1431.00

200

30
42

1431.00 QO330MQ200RB d
1555.00 QO342MQ200RB d

1431.00
1555.00

225

42

1555.00 QO342MQ225RB d

1555.00

Cover Included

#4300

6R
6R
8R

6R
14R

#4300

PK18GTA

12.50

14R

#4300

#4300

PK18GTA
PK23GTA

12.50
14.20

14R
14R

#4300

#4300

PK23GTA

14.20

14R

Above listings thru 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
a UL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b 25,000 RMS symmetrical amperes short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22,000 RMS symmetrical amperes SCCR maximum
with back-fed Type QO-VH main circuit breaker, feeding QO 10,000 AIR branch circuit breakers.
c Includes factory-installed back fed QO3100VH main circuit breaker.
d 65,000 RMS Symmetrical Amperes Short Circuit Current Rating maximum with field-installed Square D
type QGL 65,000 AIR minimum main circuit breaker feeding QO and Q1 10,000 AIR minimum branch circuit breakers.
e Side hinge door device allow 1 " on left side for door to open.
f PK23GTA and LK100AN.
g PK15GTA.

Three Phase Main Circuit Breakers


Field-installable alternate main circuit breakers for QO three phase main circuit breaker load
centers rated 70225 A. Do not exceed the load center main rating.
Amperage
70
80
90
100
110
125
150
175
200
225
Price

25k AIR
QDL32070
QDL32080
QDL32090
QDL32100
QDL32110
QDL32125
QDL32150
QDL32175
QDL32200
QDL32225
$1189.00s

65k AIR
QGL32070
QGL32080
QGL32090
QGL32100
QGL32110
QGL32125
QGL32150
QGL32175
QGL32200
QGL32225
$1628.00s

100k AIRh
QJL32070
QJL32080
QJL32090
QJL32100
QJL32110
QJL32125
QJL32150
QJL32175
QJL32200
QJL32225
$1864.00s

h When these 3-pole circuit breakers are used as the main circuit breaker of a three-phase load
center, the maximum AIR rating is 65,000 at 240 Vac and 100,000 at 208 Vac.

Three Phase Main Lug Kits


Field-installable main lugs for convertible three phase main circuit breaker load centers.
Main Lug
Amperage Rating
125
225

Catalog Number

Price

QOL3125
QOL3225

$ 44.90
105.00

Lug Wire Size


AWG/kcmil
#62/0 Cu/Al
#6300 Cu/Al

QO342MQ200

QO312L125G

For additional information, reference Catalog #1100CT9901.


2003 Schneider Electric
All Rights Reserved
9/8/03
9/8/03

DE3

uDE3A

sDE2

Discount
Schedule

1-5