Académique Documents
Professionnel Documents
Culture Documents
: Date:
-|-
3/21/2012
1. Input data
Anchor type and diameter: Effective embedment depth: Material: Evaluation Service Report:: Issued I Valid: Proof: Stand-off installation: Anchor plate: Profile Base material: Installation: Reinforcement:
HIT-RE 500-SD + HIT-V (5.8), M20 h ef,opti = 331 mm (hef,limit = 400 mm) 5.8 ETA 07/0260 11/3/2008 | 11/8/2012 design method SOFA design method + fib (07/2010) - after ETAG BOND testing e b = 0 mm (no stand-off); t = 25 mm lx x l y x t = 400 x 300 x 25 mm (Recommended plate thickness: not calculated) Rectangular hollow; (L x W x T) = 170 mm x 90 mm x 7 mm cracked concrete , C20/25, f c = 20.00 N/mm; h = 500 mm, Temp. short/long: 40/24C hammer drilled hole, installation condition: dry no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm) no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:
-|-
3/21/2012
4y Tension x
max. concrete compressive strain []: 0.00 max. concrete compressive stress [N/mm]: 0.00 resulting tension force in (x/y)=(0/0) [kN]: 154.000 resulting compression force in (x/y)=(0/0) [kN]: 0.000
Combined pullout-concrete cone failure Ap,N [mm ] 662843 yc 1.000 e c1,N [mm] 0 NRk,p [kN] 145.581
0 2
Ap,N [mm ] 320000 t Rk,cr [N/mm ] 7.00 y ec1,Np 1.000 NRk,p [kN] 381.435
2
y A,Np 2.071 max t Rk,cr [N/mm ] 9.97 e c2,N [mm] 0 g M,p 2.100
2
t Rk,ucr,25 [N/mm ] 15.00 y g,Np 1.597 y ec2,Np 1.000 NRd,p [kN] 181.636
0
s cr,Np [mm] 566 y g,Np 1.265 y s,Np 1.000 NSd [kN] 154.000
c [mm] 10000
y re,Np 1.000
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:
-|-
3/21/2012
Concrete Breakout Strength Ac,N [mm ] 1542549 e c1,N [mm] 0 NRk,c [kN] 207.371
0 2
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:
-|-
3/21/2012
5. Displacements
The displacement of the highest loaded anchor should be calculated according to the relevant approval under the effect of the following characteristic loads. NSk VSk = = 19.010 [kN] 0.000 [kN]
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
6. Warnings
The design method fib (07/2010) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by filling the gap with mortar of sufficient sompressive strength (e.g. by using the Hilti Dynamic Set) or by other suitable means. The compliance with current standards (e.g. EC3) is the responsibility of the user Characteristic bond resistances depend on short- and long-term temperatures. Please contact Hilti to check feasibility of HIT-V rod supply. Checking the transfer of loads into the base material is required in accordance with fib (07/2010)! To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading!
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:
-|-
3/21/2012
7. Installation data
Anchor plate, steel: Anchor type and diameter: HIT-RE 500-SD + HIT-V (5.8), M20 Profile: Rectangular hollow, 170 mm x 90 mm x 7 mm Installation torque: 0.150 kNm Hole diameter in the fixture: df = 22 mm Hole diameter in the base material: 24 mm Plate thickness (input): 25 mm Hole depth in the base material: 331 mm Recommended plate thickness: not calculated Minimum thickness of the base material: 379 mm Cleaning: Premium cleaning of the drilled hole is required Annular gap must be removed by e.g. filling the holes with mortar of sufficient compressive strength.
50.0 5 4 6 150.0
3 50.0 200.0
2 50.0 200.0
c -x -
c +x -
c -y -
c +y -
Anchor 4 5 6
x 0 -150 150
50.0 c -x -
150.0 c +x -
c -y -
c +y -
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Company: Specifier: Address: Phone I Fax: E-Mail: Page: Project: Sub-Project I Pos. No.: Date:
-|-
3/21/2012
Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan