The ZX0 compact switchboards, independent of their environment and maintenance-free, ensure perfect power distribution and fulfil the specific requirements of the users. Reliability, economy and the high safety standard are outstanding criteria which speak for ZX0.
2 2
Self-supervision Monitoring Adjusted maintenance Reduced life cycle costs Trend analysis
Tailor-made for the individual requirements. Circuit-breakers Switch-disconnectors with fuses Switch-disconnectors
The free choice of the optimum switching device for the relevant application ensures that the technical and economic conditions are completely fulfilled. The practical busbar plug-in method for connection of individual system blocks makes simple assembly possible. It is no longer necessary to open up the gas-tight units.
With its high versatility and adaptability, the system permits the combination of all variants into complete switchboards.
12 12 28 75 1.0 50/60 ...1250 ...800 ...630 ...63 ...25 ...25 63 63 ca. 60 ca. 60 SF6 4) 1.47 1.3 1.2 150 250 250
1)
17.5 17.5 38 95 1.0 50/60 ...1250 ...800 ...630 ...50 ...20 ...20 50 50 O - 0.3 s - CO - 3 min - CO 3) ca. 60 ca. 60 SF6 4) 1.47 1.3 1.2 150 250 250 60, 110, 220 DC 5) IP 65 IP 4X 6) + 40 + 35 - 25 ... 1000 1950 8)/1650 9) 850 400
1)
24 24 50 1) 125 1.0 50/60 ...1250 ...800 ...630 ...50 ...20 ...20 50 50 ca. 60 ca. 60 SF6 4) 1.47 1.3 1.2 150 250 250
IP 65 IP 4X 6) C C C m mm mm mm
6) 7) 8) 9)
Higher values to international standards on request 1 bar = 100 kPa Other sequences on request Insulating gas: sulphur hexafluoride Other auxiliary voltages on request
IP 55 on request For greater altitudes, adaptation is required For all panels in a system with circuit-breaker panels For systems without circuit-breaker panels
System blocks in various designs with special functions. Compact Expandable Maintenance-free in the high voltage section Safe
ZX0
ABB Calor Emag
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
ZX0
1 11 10 9 4
7
9
1
2 3
6
1 8
3
8 5
3 5 4
7 4 6 5
Circuit-breaker panel
1 2 3 4 5 6 7 8 9 10 11 Switchbay control and protection unit REF542 (SCU) Measuring sockets for capacitive voltage indicator system 3-position switch mechanism Circuit-breaker mechanism Cable plug Ring-type current transformer Pressure relief plate External cone Vacuum circuit-breaker 3-position switch Busbars Protective gas
Switch-disconnector panel
1 2 3 4 5 6 7 Measuring sockets for capacitive voltage indicator system 3-position switch-disconnector mechanism Cable plug Pressure relief plate External cone 3-position switch-disconnector Busbars Protective gas
ZX0
ABB Calor Emag Mittelspannung GmbH Oberhausener Strasse 33 D-40472 Ratingen Petzower Strasse 8 D-14542 Glindow
Presented by:
Phone: +49(0)21 02/12-12 30, Telefax: +49(0)21 02/12-19 16 E-Mail: calor.info@de.abb.com Internet: http://www.abb-calor.de
Publication No. DECMS 2187 99 E Printed in Germany (04.99-2000-PPI)