Académique Documents
Professionnel Documents
Culture Documents
Welcome
Structure Determination with TOPAS Overview Methods of Solution
Simulated Annealing Charge Flipping 3D Fourier Analysis Simulated Annealing vs. Charge Flipping
Heiko Ress
Marketing Manager US
Conclusions
Arnt Kern
Product Manager XRD
Intensity Extraction
Le Bail, Pawley
F2(obs) : Observed structure factors yi(obs) : Observed step intensity data Structure Refinement using F2(obs): Two-Stage Method (Will, 1979) Structure Refinement using yi(obs) : Rietveld method (Rietveld, 1967, 1969)
Intensity Extraction
Le Bail, Pawley
Intensity Extraction
Le Bail, Pawley
"Profiling"
Le Bail, Pawley
For a given multiphase pattern, all profile fitting techniques supported by TOPAS can be used simultaneously to describe individual phase contributions to the full pattern
Structure determination in the presence of additional phase(s) with known or unknown structure Successful structure determination of 2 phases simultaneously (simulated annealing) Support of user-defined refinement parameters / refinement models Computer algebra system for function minimization and for the application of linear and non-linear restraints
Rigid bodies
Rigid body editor for graphical creation of rigid bodies Spherical harmonics to account for preferred orientation ...
Simulated Annealing
This procedure is typically applied to observed structure factors, F2(obs), but has been extended to step intensity data, yi(obs) TOPAS (Coelho, 2000)
A preconceived (at least partial) structure model is required, "with its parameters reasonably close enough to the final values" This automatically raises the question: "How far off the position of an atom may be and the refinement still brings it in?"
~6 times faster
Individual atoms
Nr. of DoFs : Nr. of solutions : Time : Success rate : 51 11 2090 sec. 190 sec / solution
a c
Charge Flipping
a c
~15 sec.
3D Fourier Analysis
Atom picking capabilities with recognition of special positions Allows simultaneous display of electron densities, picked atoms, and crystal structures The ideal tool for structure completion, if Simulated Annealing or Charge Flipping methods only deliver partial structure models
d~0.77
Proposed solution (organizers):
La18W10O57, Z = 2 P-62c (No. 190) W6 half occupied site (very short W4-W6 interactomic distance 2.42 )
~4 sec.
~4 sec.
d~1.30
26 sec. 44 sec.
26 sec. 44 sec.
Charge Flipping:
No use of chemistry / trial structure models. Important advantage! Requires high quality data Even if the structure doesnt solve completely, heavy atoms and / or molecular fragments can often be found very quickly, which greatly assists subsequent simulated annealing structure determination Very fast; structures can be (partially) solved in seconds up to a few minutes, i.e. faster than one typically can create a start model / rigid body for simulated annealing
Charge Flipping
3D Fourier Analysis
Poor quality (powder) data Trial (random) structure model required High quality (powder) data No structure model required
Structure solved
Benefits
Transmission setup to minimize preferred orientation effects High-energy radiation (Mo, Ag) to minimize sample transparency effects One single instrument setup equally suited for both organic and inorganic materials
Range of options:
Capillary sample holder
The ideal machine for laboratory crystal structure and PDF analysis
Cu-, Mo-, and Ag-radiation Primary monochromators for pure Ka1 radiation for all wavelengths Both parallel beam and focussing Gbel mirrors for high flux for all wavelengths Dedicated LYNXEYE detectors for all wavelengths
Example ICN-SbF5
D8 ADVANCE with capillary stage and LYNXEYE detector, Mo-radiation Sample consists of 3 phases: Structure determination of ICNSbF5 with simultaneous refinement of 2 additional phases via Le Bail and single line fitting, respectively
Dinnebier (2009)
The fall in diffracted intensities can be larger than two orders of magnitude across the pattern The goal: Collection and analysis of powder diffraction data with near-constant counting statistics (David, 1992; Madsen, 1992)
I ~ LP * thermal vibration * f2
Conclusions
Charge Flipping is generally suggested to start with from the beginning due to its ease of use and speed. Chances are high to find at least a partial solution, which may then greatly assist to create a better trial structure for subsequent Simulated Annealing runs.
Any Questions?
Please type any questions you may have in the Q&A panel and then click Send.
49
50
think forward
Completely automated operation Structure information when you need it Quick, reliable and effective Benchtop system designed for synthetic chemists join contest today: http://www.bruker-axs.com SMART X2S: Automated chemical crystallography solution
51
Bruker Confidential
10/2/2009
52
Bruker Confidential
Visit us at:
Gulf Coast Conference (GCC) Oct 13-14, Galveston, TX Geological Society of America (GSA) Oct 18-21, Portland, OR Cement Chemists Society Conference Oct 19-23, Orlando, FL Pittsburgh Diffraction Congress Oct 29-31, University of Georgia, Athens, GA Buffalo-Hamilton-Toronto Symposium (BHT) Nov 6, Hamilton, ON American Association of Pharmaceutical Scientists (AAPS) Nov 9-11, Los Angeles, CA Materials Research Society (MRS Fall) Dec 1-3, Boston, MA
www.bruker-axs.com
53 Bruker Confidential
www.bruker-axs.com