LIST OF APPLICABLE ELECTRICAL STANDARDS


The relevant applicable standards Indian as well the international are listed below. In case the bidder offers the product of international make then the product shall confirm to the corresponding international standards viz. IEEE/IEC/NEMA etc. Or alternatively the product offered should confirm to Indian Standard. A. INDIAN STANDARDS 1. General Requirements : IS 732 IS 900 IS 1271IS 1646 IS 1866 IS 1882 IS 1886IS 1913IS 2032IS 2165IS 2274IS 2309IS 3034 IS 3043 IS-3072 - Part -1 IS 3106 IS 3638 IS 3646 IS 3716 IS 3842 IS 4004 IS 4146 IS 4201IS 5571IS 5572 IS 5780 IS 5908Code of practice for electrical wiring installations ( System voltage not extending 650 volts ) Code of practice for installation and maintenance of Induction Motors Classification of insulting materials for electrical machinery and apparatus in relation to their thermal stability in service Code of practice for fire safety of buildings (general) Electrical Installations Code of practice for maintenance of insulating oil. Code of practice for outdoor installation of public address systems. Code of practice for installation and maintenance of Transformers General and safety requirements of electric lighting fittings Graphical symbols used in electric technology. Guide for insulation coordination Code of practice for electrical wiring installations (System voltage exceeding 658 volts) Code of practice for the protection of buildings and Allied structures against lightning. Code of practice for fire safety of industrial buildings Electrical generating and distributing stations. Code of practice for earthing Code of practice for installation and maintenance of switchgear (System voltage not exceeding 1000 volts) Code of practice for selection, installation and maintenance of fuses (voltage not exceeding 650 volts) Application guide for gas-operated relays. Code of practice for interior illumination. Application guide for insulation coordination Equipment located in hazardous situations. Application guide for electrical relays for AC system. Application guide for non-linear resisted type lightning arrestors for AC system Application guide for voltage transformers. Application guide for current transformers. Guide for selection of electrical equipment in hazardous area. Classification of hazardous areas for electrical installations. Intrinsically safe electrical apparatus and circuits. Method of measurement of electrical installations in buildings.

A. EQUIPMENT 1. Switchgear (a) General : IS 375 IS 694 - Part 1 Marking and arrangement for switchgear bus-bars, main connections and auxiliary winding. PVC insulated cables ( for voltages up to 100v) with copper conductors.

http://www.ecosustainenergy.com/Applicable%20Standards.htm (1 of 4)3/20/2010 11:19:23 PM

Applicable Electrical Standards

IS 1248 IS 2147 IS 2208 IS 2705 IS 3156 IS 3202IS 3231 IS 4047IS 4237 IS 5987 (b) 6.6 KV IS 335 IS 2516 Part 1 Sec.2 IS 3427 (c) 415 Volts : IS 722 IS 1951IS 2516 - Part 1sec.1 Part II/Sec.2IS 2419 BS 4752 BS 6231 IEC 157 (d) M.C.C. : IS 1554 -Part I IS 1822 IS 2959 IS 3961-Part II IS 5124 IS 2959 (e) Invertors : IS 391 -

Direct acting electrical indicating instruments. Degrees of protection provided for enclosures for low voltage switchgear and control gear. HRC cartridge fuse links up to 650 V. Part I, II & III Current transformers. Part I, II & III Voltage transformers. Code of practice for climate proofing of electrical equipment. Electrical relays of power system protection. Heavy duty air break switches and composite units of air-break switches and fuses for voltages not exceeding 1000 volts. General requirements for switchgear and control gear for voltages not exceeding 1000V. Code of practice for selection of switches (voltage not exceeding 1000V)

Insulating oil for transformers and switchgear. Alternating current circuit breakers Requirements and tests for voltage ranges 1000 to 11000 volts. Metal enclosed switchgear and controlgear for voltages above 1000 V but not exceeding 11000 V.

AC electricity meters. PVC sleeving for electrical purposes.

AC circuit breakers requirements and tests for voltages not exceeding 1000 V. Dimensions of electrical indicating instruments. Circuit breakers of rated voltage up to and including 1000 volts and 1200 volts dc. PVC insulated cables for switchgear wiring. Low voltage distribution switchgear circuit breakers.

PVC insulated (heavy duty) electric cables for working voltages up to and including 1100 volts. AC motor starters of voltage not exceeding 1000 volts. AC contactors of voltage not exceeding 1000 V. Recommended current ratings for PVC insulated and PVC sheathed cables. Code of practice for installation and maintenance of AC induction motor starters (voltage not exceeding 1000V). AC contactors of voltage not exceeding 1000 V.

Mains transformers for electronic equipment.

2. Transformers : IS 335 IS 2026 IS 2099 IS 3070 IS 3637 IS 3639 3. Motors : IS 325 IS 4691IS 4722 4. Batteries : IS 1652 BS 440 Stationery cells and batteries, lead-acid type (with plants positive plates). Stationery batteries Three phase induction motors. Degrees of protection provided by enclosures for rotating electrical machinery. Rotating electrical machines Insulating oil for transformers and switchgear. Power transformers. High voltage porcelain bushings. Lightning arrestors for AC systems. Gas operated relays. Fittings and accessories for power transformers

http://www.ecosustainenergy.com/Applicable%20Standards.htm (2 of 4)3/20/2010 11:19:23 PM

Applicable Electrical Standards

5. Cables : IS 1554 -Part I & II IS 1753 IS 3961 IS 3975 IS 5819 IS 5831 6. Altornators : IS 7132 IS 5422 IS 7306 IEC 60028 Ed. - 2.0 b: 1925 IEC 60034-1 Ed.11.0 b:2004 IEC 60034-11 Ed.2.0 b: 2004 IEC 60034-12 - Ed.2.0 b: 2002 IEC 60034-14 -Ed.3.0 b:2003 IEC 60034-15 - Ed.2.0 b : 1995 IEC 60034-16-1 Ed.1.0 b:1991 IEC 60034-18-1 Ed.1.0 b : 1992 1973 Guide for testing synchronous machines 1996 Turbine type generators 1974 Methods for determining synchronous machine quantities from tests. International standard of resistance for copper Rotating electrical machines Part 1 : Rating and performance Rotating electrical machines Part 11 : Thermal protection. Rotating electrical machines Part 12 : Starting performance of single-speed three-phase cage induction motors. Rotating electrical machines Part 14 : Mechanical vibration of certain machines with shaft heights 56 mm Higher Measurement, evaluation and limits of vibration severity. Rotating electrical machines Part 15 : Impulse voltage withstand levels of rotating a.c.machines with form-wound stator coils. Rotating electrical machines Part 16 : Excitation systems for synchronous machines Chapter 1 : Definitions. PVC insulated (heavy duty) electric cables for working voltages up to and including 1100 volts and for upto 33 KV. Aluminium conductors for insulated cables. Part II Recommended current ratings for cables. Mild steel wires, strips and tapes for armouring cables. Recommended short-circuit ratings of high voltage cables. PVC insulation and sheaths of electric cables

Rotation electrical machines Part 18 : Functional evaluation of insulation systems Section 1 : General guidelines & Section 21 : Test procedures. Rotating electrical machines Part 18 : Functional evaluation of insulation systems Section 31 : Test procedures for formIEC 60034-18-31 Ed wound windings Thermal evaluation and classification of insulation systems used in machines up to and including 50 MVA 1.0 b : 1992 and 15 kV IEC 60034-2 Ed.3.0 Rotating electrical machines Part 2 : Methods for determining l losses and efficiency of rotating electrical machinery from b : 1972 tests (excluding machines for traction vehicles) IEC 60034-2A Ed. 1.0 Rotating electrical machines Part 2 : Methods for determining Losses and efficiency of rotating electrical machinery form b : 1974 tests (excluding machines for traction vehicles) First supplement : Measurement of losses by the calorimetric method. IEC 60034-3 Ed. Rotating electrical machines Part 3 : Specific requirements for cylindrical rotor synchronous machines 5.0 b : 2005 IEC 60034-4 Ed.2.0 Rotating electrical machines Part 4 : Methods for determining synchronous machine quantities from tests. b : 1985 IEC 60034-5 Ed 4.0 Rotating electrical machines Part 5 : Degrees of protection provided by the integral design of rotating electrical machines b : 2000 (IP code) Classification. IEC 60034-6 Ed.2.0 Rotating electrical machines Part 6 : Methods of cooling (IC code). b : 1991 IEC 60076-1 Ed.2.1 Power transformers Part 1 : General b : 2000 IEC 60076-11 Ed.1.0 Power transformers Part 11 : Dry-type transformers b : 2004 IEC 60076-2 Ed.2.0 Power transformers Part 2 : Temperature rise b: 1993 IEC 60076-8 Ed.1.0 Power transformers Part 8 : Application guide b:1997 IEC 60079-0 Ed.4.0 Electrical apparatus for explosive gas atmospheres Part 0 : General requirements b:2004 IEC 60079-10 Ed.4.0 Electrical apparatus for explosive gas atmospheres Part 10 : Classification of hazardous areas b:2004 IEC 60086-1 Ed.9.0 Primary batteries Part 1: General en:2000 IEC GUIDE III IEC/TS 60034-16 IEC- 62026 IEC-62040 IEC-60502 IEC-60287 Selection of Rotating Machinery Power Transformer General, Selection, Testing etc. Low Voltage Switchgear Uninterrupted Power Supplies Power Cables Upto 30 Kv-General Requirement, Selection Power Cables Testing

http://www.ecosustainenergy.com/Applicable%20Standards.htm (3 of 4)3/20/2010 11:19:23 PM

Applicable Electrical Standards

IEC-60255

Requirements For Protective Relays

@2006 Ecosustain Energy Systems Pvt. Ltd. All rights reserve Contact Ecosustain Energy Systems Pvt. Ltd.

http://www.ecosustainenergy.com/Applicable%20Standards.htm (4 of 4)3/20/2010 11:19:23 PM

Vous aimerez peut-être aussi