PR 750 Series General Purpose LVDT Position Sensors

Features

Technical Bulletin 1011

Standard 3/4 inch (19 mm) diameter Ranges of 0.050 inch to 10 inches Non-linearity less than 0.25% of FRO 220F (105C) operating temperature Coil assembly sealed to IEC IP-61 Magnetically shielded SS housing

Typical Applications

Machine Tools Materials Testing Industrial Robots Checkweigher Scales Packaging Machinery Valve Position Sensing Hydraulic Cylinder Position Automatic Assembly Equipment

Description
Macro Sensors PR 750 Series of 3/4 inch (19 mm) diameter AC-Operated LVDTs are general purpose contactless linear position sensors for both OEM applications and end user requirements. They are available in full scale measuring ranges from 0.050 inch (1.25 mm) to 10 inches (250 mm) and offer a radial core-to-bore clearance of 0.031 inches (0.75 mm) with the standard 0.25 inch (6.35 mm) core supplied. PR 750 Series sensors feature the high resolution, excellent repeatability, and low hysteresis associated with LVDT technology, as well as the highest sensitivity consistent with good linearity. The maximum linearity error for any of these sensors is 0.25% of full range output (FRO), using a statistically best-fit straight line derived by the least squares method. The proven reliability of PR Series LVDTs is a direct result of manufacturing processes and assembly techniques developed and optimized by Macro Sensors personnel over many years of making LVDTs. Their environmental robustness stems from the materials of their construction, such as glassfilled polymer coil forms for thermal stability and stainless steel housings that act as magnetic shields to reduce the effects of any external AC magnetic fields. Their external sealing meets IEC standard IP-61. Macro Sensors offers several standard options that permit a user to customize PR 750 LVDTs, including Teflon bore liners, metric threaded cores, smaller diameter cores for greater core-tobore clearance and/or lower core mass, and construction for resistance to mild nuclear radiation. In addition to these standard options, Macro Sensors can design and produce a variety of custom PR 750 LVDTs, including units with different lead wire colors, configurations, exit points, and in-line connectors; vented units for operation in pressurized fluids; and units for higher ambient temperatures. Contact the highly experienced Applications Engineers at Macro Sensors for help with any special requirements. All PR 750 Series LVDTs will operate properly with any conventional differential input LVDT signal conditioners, but operation with ratiometric input signal conditioning circuits is not recommended. Macro Sensors offers a full line of LVDT signal conditioners that will deliver optimum performance from any PR 750 Series LVDTs. Details can be found in series 9000 technical bulletins.

TM

Innovators in Position Sensing

D i v i s i o n O f H o w a r d A . S c h a e v i t z Te c h n o l o g i e s , I n c .

PR 750 Series
General Specifications
Input Voltage: Input Frequency: Linearity Error: Repeatability Error: Hysteresis Error: 3.0 Vrms (nominal) 2.5 - 3.3 kHz 0.25% of FRO < 0.01% of FSO < 0.01% of FSO
0.250 [6.35]
RED
CORE

Technical Bulletin 1011

6 #28 AWG TEFLON INSULATED LEADS 12 INCHES [300] LONG

A
0.750 [19]

0.313 [8]

Operating Temperature: -65F to +220F (-55C to +105C) Thermal Coefficient of Sensitivity: Vibration Tolerance: Shock Survival: -0.01%/F (nominal) (-0.02%/C nominal) 20 g to 2 kHz 1000 g, 11 ms

B
SEC 1

#6-40 UNF-2B STANDARD M4 x 0.7, 6H METRIC .38 (9.6) MIN. DEPTH

YELLOW
PRIMARY

BLUE GREEN
SEC 2

CONNECT BLUE AND GREEN FOR DIFFERENTIAL OUTPUT

BROWN

BLACK

WIRING DIAGRAM

All dimensions in inches [mm]

Specifications
Parameter
Nominal Range (inches) Nominal Range (mm) Sensitivity (mV/V/.001 inch) Sensitivity (mV/V/mm) Impedance, Primary () Dimension A (inches) Dimension A (mm) Dimension B (inches) Dimension B (mm) Dimension N (inches) Dimension N (mm) Weight, Body (ounces) Weight, Body (grams) Weight, Core (ounces) Weight, Core (grams)

PR 750 PR 750 PR 750 -050 -100 -200 0.05 1.25 6.5 255 400 1.13 28.7 0.80 20.3 0.56 14.3 0.9 26
0.14

PR 750 -500 0.50 12.5 0.65 25 1400 5.02 127.5 3.45 87.6 2.51 63.7 2.8 80 0.72 20.4

PR 750 PR 750 PR 750 -1000 -2000 -3000 1.00 25 0.65 25 1650 6.51 165.4 3.45 87.6 3.25 82.5 3.8 108 0.72 20.4 2.00 50 0.39 15 1875 10.02 254.5 5.30 134.6 5.01 127.2 5.0 142 1.20 34.0 3.00 75 0.26 10 1950 12.75 323.9 6.20 157.5 6.38 161.9 7.7 218 1.34 41.7

PR 750 -4000 4.00 100 0.18 7.1 425 15.20 386.1 6.20 157.5 7.60 193.0 9.8 278 1.34 41.7

PR 750 -5000 5.00 125 0.13 5.1 1050 17.75 450.9 6.20 157.5 8.88 225.4 11.7 332 1.34 41.7

PR 750 PR 750 -7500 -10000 7.50 190 0.12 4.3 1380 22.85 580.4 7.00 177.8 11.43 290.2 16.9 480 1.51 42.8 10.00 250 0.08 3.1 1050 30.64 778.3 9.50 241.3 15.32 389.1 20.5 582 2.20 62.4

0.10 2.5 4.0 155 1000 1.75 44.5 1.25 31.7 0.88 22.2 1.4 40 0.22 6.2

0.20 5.0 2.4 95 1900 2.50 63.5 1.65 41.9 1.25 31.7 1.7 48 0.30 8.5

4.0

Ordering Information
For For For For For For For standard PR 750, order by model number with range metric threaded core option, add -006 after model number with range Teflon bore liner option, add -010 after model number with range (not available with -080 option) small diameter core option, add -020 after model number with range mild radiation resistant option, add -080 to model number with range (not available with -010 option) multiple options, add sum of dash numbers after model number with range accessories, please visit our website at www.macrosensors.com.
TM

Innovators in Position Sensing


All specifications subject to change without notice. 2006 Macro Sensors 03/13/06

D i v i s i o n O f H o w a r d A . S c h a e v i t z Te c h n o l o g i e s , I n c .

7300 US Route 130 North, Bldg. 22 Pennsauken, NJ 08110-1541 USA tel: 856-662-8000 fax: 856-317-1005 www.macrosensors.com lvdts@macrosensors.com