GW-3KP240L-GW WIND CONTROLLER

MANUAL

WIND CONTROLLER MANUAL

GW-3KP240L-GW WIND CONTROLLER MANUAL


. Summary GW-3KP240L-GW wind power controller adopts the American Intel Micro-computer control and static state switch technology. There are perfect charging and discharging control circuits in the controller, protect the storage battery and wind generator units when charge to storage fully. It has high integration, high efficiency, full protection, and high cost-effective, can be widely applied to the field of new energy generation. 1) The control circuit and the main circuit are separated completely. 2) PWM control method 3) LCD display function, can display output voltage and unload begin voltage. 4) Parameter point can be programmed and settled. 5) Stable and reliable performance. 1.1 Technical parameter type index Rated powerKW Unload voltage (Vdc) Operating ambient environment Operating altitude (m) GW-3KP240L-GW (100604002) 3 312(can set) -20~+50 5000

. Installation
2.1 The requirement and management of installation 1) Please keep the strength to the equipment get balance and uniformity when the equipment was hoisted or conveyed, lest the equipment inclining or sliding, even other serious danger. 2) The flammable and explosive things are forbidden in the installation place, avoid happening fire. 3) Installation place wants to be well ventilated, should avoid small animal in the meantime(the rat snake etc.) Entering into the machine by following to connection bore, otherwise will result in short-circuit surprised trouble etc., such as damage machine, fire etc. 4) The humidity of installing must not be over 90% and no sweat, without the equipment will be broken or happen fire or other danger. 5) Dont clean the surface with the corrode solvent; otherwise the paint will break off even, thereby having creepage. 6) Avoid equipment beside the children room and elders one, or else the noise of the current and Line up fan will have a disadvantageous effect on them. 2.2 Field condition In order to ensure good performance and long service life. The choice of the system should be installed according to the following demands: Well ventilation. Ambient temperature -10+50. The humidity of installing must not be over 90% and no sweat, Avoid keeping bask. The surround dings can't pile up a timber, the cotton dress etc. inflammable and explosive substance. Have no dust, oil dust, floating fiber and metal particle. Solid and vibrant less foundation;

. Connection and Operation


3.1 Connection attention 1) Before wiring, please make sure the battery voltage is in broken state, the power is cut off. In case get an electric shock and fire hazards. 2Please make sure the electrical engineering professionals wiring. In case get an electric shock and fire
2

WIND CONTROLLER MANUAL

hazards. 3Connector must have reliable grounding. In case get an electric shock and fire hazards. 4Wiring, make sure to ensure the correct wiring. In case get an electric shock and fire hazards. 5Do not touch the terminal or circuit boards. Do not shorted terminals. In case get an electric shock and fire hazards. 6Please don't do the test of withstand voltage to the cabinet set, or else will hurt semi-conductor component. 7) All switches are "cut", check whether the load is short-circuited or not. 3.2 Connection terminals introduction When connecting, please according to the logo of cabinet, notice the polarity, and earthing wind input DC output AC input to fake load earth L N 1 2 E

3.3 Main circuit terminal cable size and pressure-wire terminal: For the sake of using safely and conveniently, please consult the list and choose properly terminal cable size and pressure-wire terminal. Item Wind input DC output+AC input LN To Fake load12 Earth Wire size 42 42 0.5 2 42 42 Pressure-wire terminal

3.4 Connection attention: When connecting, please notice the polarity; Connect the wind generator AC output to the wind input ~ ~ ~of controller,and then the machine's "DC output + -" received GWG-3K240SL-TW's "DC input + -" on.The machine "AC input LN" received a single-phase mains on. above all, must connect the fake to load to the load bin. 3.5 Boot-start sequence 1) When operating, please first close the wind input loop and the controller will run normally. 2) Shutdown if necessaryyou just tuen off the wind switch.

.Panel device and set value code explanations 4.1 Panel equipments explanation
Equipments Wind input switch 4.2 LCD display explanation 4.2.1 key-press introduction The controller is of six key-press, they are : SET UP1 DOEN1 UP2 DOEN2 SAVE Function explanation Stop/Start of the wind input

1Press set, the system enter into setting mode, press the save, the system will be out of the setting mode, save the current setting.
3

WIND CONTROLLER MANUAL

2UP1: look over front page through the key-press or plus 1 when modify parameter. 3DOWN1look over next page through the key-press or minus1 when modify parameter. 4UP2 the device do not use this button. 5DOWN2 the device do not use this button. 4.2.2 Interface introduction 1Initialization interface

Hello !
First startup, the system will enter into the initialization interface, waiting for 2 seconds, enter into the main interface, as follows: 2The main interface

OUTPUT VOLTAGE 000.0V


This interface shows the current controller output voltage. Pressing the middle button or to enter the current display interface..

UNLOAD VOLTAGE 312.0V


This interface shows the current output current and unloading. Long press "SET" button until the LCD screen that the lower left corner shows "SET", then the default uninstall start voltage can be modified point. Pressing the middle of the " " or " " button to adjust the Uninstall start voltage. If the system can not detect the key-press operating in 16 seconds, system will return to normal state, the current modify parameter is invalid.

. Breakdown finding and solving measures


The fault or abnormal operation, please operate in accordance with the following urgent measures: Quickly remember fault phenomena, turn off Operating in order; First cut off wind input loop; Cut off DC output loop quickly; Wait for tow minutes or more long time and make sure the electric charge of capacitances is empty. Cut off boat-shaped switch; . Other notices 6.1 Connector must have reliable grounding. 6.2 When the system is working in order to prevent accidents and avoid electric shock, do not open the machine cover. 6.3 That the power supply certainly has radiation quantity belongs to normal phenomenon during the period of using, but keeping airiness of install the environment to spread heat, clean sweep, can't stop well ventilated bore specially. 6.4 Other circumstances please contact with the headquarters directly.
4