Vous êtes sur la page 1sur 14

SELECTION CHART : FUSE PROTECTED DOL STARTER FEEDERS

TYPE '2' Co-ordination, Iq=50 kA at 415V, 3, 50 Hz.


as per Standards: IEC 60947-4-1, IS 13947 (Part 4/Sec 1), EN 60947-4-1
Sr.
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Motor Rating: 1, 240V, 50 Hz


hp
kW
In (A)

0.25
0.5

0.18
0.4

2
3.6

0.75

7.5

1.25
2
3

0.9
1.5
2.25

8
9.5
14

Motor Rating: 3, 415V, 50 Hz


hp
kW
In (A)
0.125
0.09
0.4
0.16
0.12
0.45
0.2
0.15
0.57
0.25
0.19
0.75
0.33
0.25
0.9
0.5
0.37
1.2
0.75
0.55
1.6
1
0.75
2.1
1.5
1.1
2.7
1.75
1.3
3
2
1.5
3.5
2.5
1.8
4.8
3
2.25
5
4
3
6.4
5
3.7
7.9
5.5
4
8.5
6
4.5
9
7.5
5.5
11.2
10
7.5
14.8
12.5
9.3
19
15
11
22
17.5
13
24
20
15
29
25
18.6
35
30
22.5
40
35
26
47
40
30
55
45
33.5
60
50
37
66
60
45
80

Contactor
Type
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 9
MNX 12
MNX 12
MNX 18
MNX 25
MNX 25
MNX 32
MNX 32
MNX 40
MNX 45
MNX 70
MNX 70
MNX 70
MNX 80
MNX 95

Overload Relay
Type
Range (A)
MNX-R3
0.3 - 0.5
MNX-R3
0.3 - 0.5
MNX-R3
0.45 - 0.75
MNX-R3
0.6 - 1.0
MNX-R3
0.6 - 1.0
MNX-R3
0.9 - 1.5
MNX-R3
1.4 - 2.3
MNX-R3
1.4 - 2.3
MNX-R3
2.0 - 3.3
MNX-R3
2.0 - 3.3
MNX-R3
3-5
MNX-R3
4.5 - 7.5
MNX-R3
4.5 - 7.5
MNX-R3
4.5 - 7.5
MNX-R3
6 - 10
MNX-R3
6 - 10
MNX-R3
6 - 10
MNX-R3
9 - 15
MNX-R3
9 - 15
MNX-R3
14 - 23
MNX-R3
14 - 23
MNX-R3
20 - 33
MNX-R3
20 - 33
MNX-R4
30 - 50
MNX-R4
30 - 50
MNX-R4
30 - 50
MNX-R4
45 - 75
MNX-R4
45 - 75
MNX-R4
45 - 75
MNX-R4
66 - 110

Nominal Backup fuse


Type
Rating (A)
HF
2
HF
2
HF
2
HF
4
HF
4
HF
6
HF
6
HF
8
HF
10
HF
10
HF
16
HF
16
HF
16
HF
20
HF
20
HF
20
HF
25
HF
32
HF
32
HF
50
HF
63
HF
63
HF
63
HN, 000*
80
HN, 000*
80
HN, 000*
100
HN, 000*
100
HN, 000*
100
HN, 00
125
HN, 00
125

31

75

55

100

MNX 110

MNX-R4

66 - 110

HN, 00 #

160

32

90

67.5

120

MNX 140

MNX-R5

90 - 150

HN, 0

200

33

100

75

135

MNX 140

MNX-R5

90 - 150

HN, 0

200

SELECTION CHART : FUSE PROTECTED DOL STARTER FEEDERS


TYPE '2' Co-ordination, Iq=50 kA at 415V, 3, 50 Hz.
as per Standards: IEC 60947-4-1, IS 13947 (Part 4/Sec 1), EN 60947-4-1
Motor Rating: 1, 240V, 50 Hz
hp
kW
In (A)
34
35
36
37
38
39
40
41
42
43
44
45
46
47

NOTES:
1)

Motor Rating: 3, 415V, 50 Hz


hp
kW
In (A)
110
80
139
125
90
165
150
110
200
175
130
230
197
147
260
200
150
275
215
160
280
225
168
300
245
180
320
270
200
340
300
225
385
335
250
425
400
300
500
430
315
535

7)
8)

Overload Relay
Type
Range (A)
MNX-R5
90 - 150
MNX-R5
135 - 225
MNX-R5
135 - 225
MNX-R5
180 - 300
MNX-R5
180 - 300
MNX-R5
180 - 300
MNX-R5
180 - 300
MNX-R5
270 - 450
MNX-R5
270 - 450
MNX-R5
270 - 450
MNX-R5
270 - 450
MNX-R5
270 - 450
MNX-R5L
340 - 570
MNX-R5L
340 - 570

Nominal Backup fuse


Type
Rating (A)
HN, 0
200
HN, 1
250
HN, 1
250
HN, 1
315
HN, 2
400
HN, 2
400
HN, 2
400
HN, 2
400
HN, 2
400
HN, 3
500
HN, 3
500
HN, 3
500
HN, 3
630
HN, 3
630

The Full Load Current (FLC) indicated for Single phase motors are of 'Capacitor start motors' and for 3-phase motors are of
'Squirrel-cage Induction motors' at full load.
Motors considered are with speeds more than that mentioned below:
Upto
10 hp - 750 rpm
30-125 hp - 500 rpm
10-30 hp - 600 rpm

2)
3)
4)
5)
6)

Contactor
Type
MNX 185
MNX 185
MNX 225
MNX 265
MNX 265
MNX 325
MNX 325
MNX 325
MNX 325
MNX 400
MNX 550
MNX 550
MNX 550
MNX 550

125-300 hp - 375 rpm

Contactors / S-D-Fs indicated are of the minimum ratings. Higher rating of Contactors and S-D-Fs can be used.
Normal Motor starting time, Power factor and Efficiency is assumed in all cases.
* : Only size '000' fuses to be used with FNX 100 S-D-F.
# : Only size '00' fuses should be used with FNX 160 S-D-F.
Selection is valid only for complete L&T combinations ie. "S-D-F + Fuse + Contactor + O/L. Relay".
Compliance to Type '2' co-ordination is not assured in case these combinations are changed
to accommodate another brand / rating of products like S-D-F / Fuse etc.
All S-D-F ratings are AC-23A as per IS 13947 (Part 3), IEC 60947-3 & EN 60947-3
Switchgear selection for motors with longer starting times can be made available on request.

USE PROTECTED DOL STARTER FEEDERS


nation, Iq=50 kA at 415V, 3, 50 Hz.
947-4-1, IS 13947 (Part 4/Sec 1), EN 60947-4-1
S-D-F
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 32 / FNX 32
FN 63 / FNX 63
FN 63 / FNX 63
FN 63 / FNX 63
FN 63 / FNX 63
FN 100 / FNX 100 *
FN 100 / FNX 100 *
FN 100 / FNX 100 *
FN 100 / FNX 100 *
FN 100 / FNX 100 *
FN 125 / FNX 125
FN 125 / FNX 125
FN 160 / FNX 160 #
FN 200 / FNX 200
FN 200 / FNX 200
sheet 1 of 2

ubs \ R1: 21.10.05

USE PROTECTED DOL STARTER FEEDERS


nation, Iq=50 kA at 415V, 3, 50 Hz.
947-4-1, IS 13947 (Part 4/Sec 1), EN 60947-4-1
S-D-F
FN 200 / FNX 200
FN 250 / FNX 250
FN 250 / FNX 250
FN 315 / FNX 315
FN 400 / FNX 400
FN 400 / FNX 400
FN 400 / FNX 400
FN 400 / FNX 400
FN 400 / FNX 400
FN 630 / FNX 630
FN 630 / FNX 630
FN 630 / FNX 630
FN 630 / FNX 630
FN 630 / FNX 630

sheet 2 of 2
ubs \ R0 : 15.02.05
ubs \ R1: 21.10.05

UPTO 1.5 KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 32 / FNX 33
MNX 9
MNX-R3
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

16A
3-5A
2A

Fuse links
16A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

List Price QTY


1910
775
1175
300
340
170
170
440
160
160
169
1250

Discount
25
25
25

1
1
1
1
1
1
1
1
1
1
3
1
1

1910
775
1175
300
340
170
170
440
160
160
507
1250
2000

1910
775
1175
300
340
170
170
440
160
160
169
1250

1
1
1
1
1
1
1
1
1
1
3
1
1

1910
775
1175
300
340
170
170
440
160
160
507
1250
2000

25
25
25

1910
965
1175
300

1
1
1
1

1910
965
1175
300

25
25
25

25

above 1.5KW and UPTO 3.7KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 32 / FNX 33
MNX 9
MNX-R3
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

20A
6-10A
2A

Fuse links
20A
Wiries, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

25

above 3.7KW and UPTO 7.5KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB

FN 32 / FNX 33
MNX 18
MNX-R3
Lexic 6032 27

32A
9 -15A
2A

Aux contactor
Indicating lamps

Push buttons

MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

Fuse links
32A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

340
170
170
440
160
160
169
1250

1
1
1
1
1
1
3
1
1

340
170
170
440
160
160
507
1250
2000

25

2510
1105
1600
300
340
170
170
440
160
160
250
1500

1
1
1
1
1
1
1
1
1
1
3
1
1

2510
1105
1600
300
340
170
170
440
160
160
750
1500
2000

25
25
25

5160
5250
2160
300
340
170
170
440
160
160
250
1500

1
1
1
1
1
1
1
1
1
1
3
1

5160
5250
2160
300
340
170
170
440
160
160
750
1500

25
25
25

above 7.5KW and UPTO 15KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 63 / FNX 63
MNX 32
MNX-R3
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

63A
20 - 33A
2A

Fuse links
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

63

25

above 15KW and UPTO 22.5KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 100 / FNX 100


MNX 45
MNX-R4
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

80A
30 - 50A
2A

Fuse links
80A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,

25

Panel Enclosure with painting

2000

5160
7380
3205
300
340
170
170
440
160
160
600

1
1
1
1
1
1
1
1
1
1
3

5160
7380
3205
300
340
170
170
440
160
160
1800

850

850

250
1500

3
1
1

750
1500
2000

6799
10720
3205
300
340
170
170
440
160
160
750

1
1
1
1
1
1
1
1
1
1
3

6799
10720
3205
300
340
170
170
440
160
160
2250

1000
394
2000

1
3
1

1000
1182
2000

From 26KW and UPTO 33.5KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 100 / FNX 100


MNX 70
MNX-R4
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

100A
45 - 75A
2A

CTs
100A
Ammeter with
96 x 96 x 96
100A
selector switches
Fuse links
100A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

25
25
25
25

For 37 & 45KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 125 / FNX 125


MNX 95
MNX-R4
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

125A
66 - 110A
2A

CTs
125A
Ammeter with
selector switches
96 x 96 x 96
125A
Fuse links
125A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,

25
25
25
25

Panel Enclosure with painting

3000

3000

7520
12155
3205
300
340
170
170
440
160
160
1000

1
1
1
1
1
1
1
1
1
1
3

7520
12155
3205
300
340
170
170
440
160
160
3000

1050
421
3000
4000

1
3
1
1

1050
1263
3000
4000

8660
16575
6405
300
340
170
170
440
160
160
1000

1
1
1
1
1
1
1
1
1
1
3

8660
16575
6405
300
340
170
170
440
160
160
3000

1050
520
4000
5000

1
3
1
1

1050
1560
4000
5000

For 55KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 160 / FNX 160


MNX 110
MNX-R4
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

160A
66 - 110A
2A

CTs
160A
Ammeter with
selector switches
96 x 96 x 96
160A
Fuse links
160A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

25
25
25
25

For 75KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 200 / FNX 200


MNX 140
MNX-R5
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

200A
90 - 150A
2A

CTs
200A
Ammeter with
selector switches
96 x 96 x 96
200A
Fuse links
200A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

25
25
25
25

For 110KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 250 / FNX 250


MNX 225
MNX-R5
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

250A
135 - 225A
2A

CTs
250A
Ammeter with
selector switches
96 x 96 x 96
250A
Fuse links
250A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

8660
25415
6405
300
340
170
170
440
160
160
1000

1
1
1
1
1
1
1
1
1
1
3

8660
25415
6405
300
340
170
170
440
160
160
3000

1050
520
4000
5000

1
3
1
1

1050
1560
4000
5000

16150
35915
7260
300
340
170
170
440
160
160
1200

1
1
1
1
1
1
1
1
1
1
3

16150
35915
7260
300
340
170
170
440
160
160
3600

1250
820
4000
5000

1
3
1
1

1250
2460
4000
5000

25
25
25
25

For 150/160KW MOTOR DOL SFU Feeder


SFU
Contactor
OLR
Control MCB
Aux contactor
Indicating lamps

Push buttons

FN 400 / FNX 400


MNX 325
MNX-R5
Lexic 6032 27
MNX 9 - 40
RED
YELLOW
BLUE
RED
GREEN

400A
180 - 300A
2A

CTs
400A
Ammeter with
selector switches
96 x 96 x 96
400A
Fuse links
400A
Wires, cable ducts, sleeves , feruuls, name plate, etc.,
Panel Enclosure with painting

25
25
25
25

Discounted cost
1,433
581
881
300
255
170
170
440
160
160
507
1,250
2,000

8,307

300
500
300
300
300
340

1
2
3
4
5

1,433
581
881
300
255
170
170
440
160
160
507
1,250
2,000

8,307

1,433
724
881
300

255
170
170
440
160
160
507
1,250
2,000

8,450

1,883
829
1,200
300
255
170
170
440
160
160
750
1,500
2,000

9,816

3,870
3,938
1,620
300
255
170
170
440
160
160
750
1,500

2,000

15,333

3,870
5,535
2,404
300
255
170
170
440
160
160
1,800
850
750
1,500
2,000

20,364

5,099
8,040
2,404
300
255
170
170
440
160
160
2,250
1,000
1,182
2,000

3,000

26,630

5,640
9,116
2,404
300
255
170
170
440
160
160
3,000
1,050
1,263
3,000
4,000

31,128

6,495
12,431
4,804
300
255
170
170
440
160
160
3,000
1,050
1,560
4,000
5,000

39,995

6,495
19,061
4,804
300
255
170
170
440
160
160
3,000
1,050
1,560
4,000
5,000

46,625

12,113
26,936
5,445
300
255
170
170
440
160
160
3,600
1,250
2,460
4,000
5,000

62,459