Académique Documents
Professionnel Documents
Culture Documents
RemoteProgrammingSoftwareforM1Controls
PO Box 100 3266 US Hwy 70 West Hildebran, NC 28637 828-397-4200 Voice 828-397-4415 Fax www.elkproducts.com
Rev.1.1
Products Inc.
ElkRPSoftwareProgramming
OpeningElkRPSoftware 1. DoubleclickontheRPicononyourdesktop 2. ThefirstboxtellsyoutheversionofElkRPsoftwareyouhave. 3. ThenextscreenistheAccountsFoldermainpage.Allofyouraccountsandfolderswithaccountswillbe displayed.Youcanmakeanaccountandhaveitsavedinaspecificfolder.
3. Anewboxwillcomeuptofillouttheinformationforthenewaccount.
AccountDetails 1. Theaccountdetailswillprovideinformationabouttheclientaswellasthepanel. 2. Youcanfillinthepersonalinformationoftheclientandaddnotestorememberifthereisaspecialrulenot todelete. 3. Ontherightsideofthescreenaredetailsonthepanelforinstance: a. BootVersion b. FirmwareVersion c. DateInstalled d. RPAccessCode 4. AlsolookattheM1XEPbutton.YouwouldclickonthisbuttontofindandsetuptheElkM1XEP. 5. Onthelefthandsideofthescreenisthedifferentcategorytree.Youcanselectanycategorytoexpandthe treeandmakechanges.
ConnectingtotheControlPanel 1. ClickonSetupinthemenubaratthetopofthescreen.
2. IntheboxselectCommunications.
6. Thesystemshouldnowconnecttothecontrol,theRPsoftwarewillshowwhenitisconnectedinthelower righthandpartofthescreen(GreenLight). 7. Also upon connecting you may notice the Conflict Resolution box show in the lower part of the screen (Bottomofscreeninyellow).
2. RightclickonUsersatthetoptomakeanewuser.ThiswillbringupanewboxandselectNewUser. 3. The next box will ask you how many users to make and what number to start. It will default to the next availableslot.
4. Thelastboxwillaskyouifyouwouldliketocopysettingsfromauserorusecustomvalues.
5. Nowyouwillbeonthepageofthenewuser.
2. NowleftclickonArea1tobringyoutotheArea1detailsscreen.
3. Youcanselectazoneonthemainscreentoprogramsuchaszone1. 4. Bydoubleclickingthezoneyoucannowprogramthezone.
Globals
*You can go to each section by clicking on tab. This will take you to submenu for reviewing and changing settingsassociatedwiththatsection. MiscellaneousTab 1. FromthefoldertreeleftclickonGlobals.Yourscreenshouldlooklikethefollowingscreen.
2. Onthefirsttabwecanenablethetelephonelocal&remotecontrolfromthedropdownbox.Alsowecan changeTime,DateandTemperaturedisplay. 3. IfyouneedtocheckorchangedaylightsavingstimeyoucanleftclickontheSpecifyDatesbox. 4. In case the M1 was installed in a country outside the United States you can change the country code for dialingpurposes.Thisisdonebyusingthedropdownbox. ZonesTab
1. TheFastLoopResponsetimeisthetimeazonemustbeviolatedtotriggeraresponse.Youcanchangethis numberbyincrementsof10millisecondsfrom20msto2550ms(2.55s).Changethetimeyoucantypein thetimeorusetheupdownarrowbuttons.*OnlyzoneswiththeFastLoopResponseattributeselected will follow this time. Zones that are not selected with Fast Loop Response will respond on slow loop responsetime. 2. Slow loop response time is the time the zone must be violated before the control responds. The time is adjustedthesameasthefastloopresponsetime.
3. Next option in this submenu is the Cross Zone Self Verify box. By checking this box your cross zone can verifyitselfiftrippedforasecondtimewithintheCrossZoneVerifyTime.DonotusethisfeatureonFire Zones. 4. The Cross Zone Verify Time is the maximum amount of time allowed between trips of zones in the cross zonepool(seezonessection)totripanalarm. 5. WhenenabledAudibleSystemTroublesallowsthekeypadtobeepforsystemtroublessuchaslowbattery, phonefault,ACfailure,etc. UserCodeTab
1. The M1 can haveArea1 made commontoArea2thruArea8.IfthisfeatureisusedArea1canonlybe armed if all the common areas are armed. Area 1 will be disarmed if any on other associated with it becomesdisarmed. Output1Tab
1. Youcanchangeoutput1and2fromayelpsirentoanindustrialbuzzer. 2. Thenextchoiceistheinitialalarmvolumeoutofoutput1.Thiswillallowthepaneltoincreasethevolume everytensecondsuntilitreachedthemaximumvalueprogrammed.Themaximumvaluefromoutput1is 7. 3. Maximumsirenvaluethepanelwillincreaseisinthenextselectablebox.Again7isthemaximumvalue. 4. The maximum voice on alarm activation can also be set. This will also start low and continually increase untiltheprogrammedmaxnumberhasbeenreach.Themaximumvalueis7. 5. The last setting you can change is the nonalarm voice volume. These messages would be zone status, systemstatus,andothermessagesnotrelatedtoalarmactivation. VoiceTab
1. Voicemessagescanbedisabledalltogetherorparticularcategoriescanbedisabled. Output2Tab
1. RingsUntilAutoanswerwillpermitthepaneltoanswercallsafterthisnumberorringsforuseofTelephone RemoteControlorRemoteProgramming(ElkRP).Theoptionsare0to15rings(0disables). 2. Ring/Hangup/Answer works as follows: the user to call the location hang up after a ring or two then call backandthepanelwillpickupthelinewithina45secondwindow.Inorderforthisoptiontoworkyou needtohaveRingsUntilAutoanswerprogrammedtoanumberotherthan0. 3. TheTwoListeninmustbeenabledfortheElkM1TWIorElkM1TWAinterfacetowork. 4. TwoWay Callback Timer is a timer that provides awindow forCentral Station to call back an initiate two way.
5. CSVerifyCallTimewillholdoffreportingnewalarmsafterinitialkissoff.Thephonewillbekeptopen. 6. TheSerialPort0BaudRatecanbechangedbyusingthedropdownbox.
1. ThesesettingsdeterminewhatinformationwillbesentoutofSerialPort0automatically.
1. TheMenus15RequireCodewillblockaccessofthesekeypadmenusuntilaproperusercodeisentered. 2. The6digitLocalProgrammingCodewillallowausertolocalprograminmenu9ofthekeypad.Ifthecode ischangedandforgottenitwillimpossibletoprogramatthekeypadinmenu9. 3. IfyouareusingUPBLightingyouwillneedtoprogramintheUPBLightingNetworkAddress.Thenumber canbe1255forUPBnetworkaddresses. 4. Thelevelof programmingallowedthroughthekeypadcan bechangedwith theKPProgramming Lockout dropdownbox. Telephone 1. FirstclickonTelephoneintheaccountoverviewtree.Thiswillhighlighttelephonetoblue. 2. Rightclicktobringupaboxtoselectanewtelephone.
3. Leftclickonnewtelephonetobringuphowmanynumberstomakebox.
4. Afterclickingokbuttonyouwillnowbeatthetelephonedetailspage.
5. Thetypecanbealwaysreportorsetupasabackup. 6. For a central station you need to put in the name, number, reporting format etc. You will also need to programinwhatyouwouldliketoreportinCommunicator. Communicator 1. Clickoncommunicatorinthetreetothelefttoexpandthesubmenus.
2. SelectZoneRCsbyleftclickingonit.
2. To enter lighting programming double click the left mouse button on the word Lighting. The screen will appearasbelow.
3. Youcanprogramupto256lightstheM1cancontrol.Thelightingtechnologypartnermanufactureryouare usingwilldeterminetheformat.
4. TherearedifferenttypesoflightingdevicestheM1cancontrol.Thisisanotherdropdownbox.Simplyleft clickontheOn/offswitchtobringupthebox.
2. Afteryousetthelocationclickonthecalculatebutton.ThiswillchangethetimeinthechartforSunriseand Sunset.Dontforgettosendthischangetothepanel.
Rules
1. LeftclickontheRulesinthetreeontheleftsideofthescreen.ThiswillbringyoutotheRulesscreen.Now youcanprogramtheM1tocontrolthingswithoutneedingtoknowaprogramminglanguage.
2. InordertowritearulestartbyleftclickingonNew.Theboxbelowwillappearonthescreen.
3. AruleistriggeredbytheWheneverstatement.YoucanchooseaWheneverstatementbydisplayingthe choicesinthedropdownbox.SimplyleftclickingontheWheneverwillshowtheboxbelow.
4. Writearuletoturnonalightatsunset.Choosethetimeoccurrencefromthedropdownbox.Youwillonly needtoputthemouseoverthetimeoccurrenceforthesecondmenutopopupasbelow.
5. NowjustpickAtSunset(+)fromthebox.Thetwopreviousboxeswilldisappeartorevealtheboxbelow. NextjustclickontheOKbutton.
6. Therulewillhaveawheneverstatementjustlikethescreenshotbelow.
7. ClickontheThenButtontobringupthechoicesofThenStatements.
8. ToselectthelightmovethecursortoControlLightingtobringuptheboxbelow.ClickonIndividualto indicatethelighttherulewillturnonatsunset.
9. Youwillnowhaveaboxopentoselectthelightasshownbelow.ClickOKtofinishtherule.
10. Yourruleshouldlooksimilartotheonebelow.