Property Inspection Report For Mr. and Mrs. Client 123 Wood Lane, Your Town, Illinois
Page Number 1
3/29/2010
DearMr.andMrs.Client, Itisimportantthatyouunderstandthatallcommentsofconditions,observationsandrecommendationsaremyopinions. Commentsinthereportarebasedonmyinterpretationofthevariousindustrystandardsandpractices. Throughoutthereport,allcommentsandnotesaretobeconsideredasstartingwiththephraseinmyopinion. Bewarethatothersmaydisagreeorhaveadifferentperspectivethanmine.Notallhomeinspectorsortradesmenagreeon defects,installationmethods,seriousnessorotherconsiderations.Theinspectionreportprovidesyouwithinformationabout thehomethatIbelievetobeofconcernorinterest.Youarepayingmeformyopinionandthereportisareflectionofthat. Inanattempttoavoidredundancyinthereport,anyandallrecommendationsorcommentsforrepair,replacement,additional evaluation,correctiveactionorsimilarshouldonlybeperformedusingrecognizedmethodsandmaterialsbyaqualified/ licensedprofessionalintheirrespectivefield.Youshouldalsobeawarethatinsomeareasprofessionallicensingofsome tradesisnotrequiredbymunicipalorothergovernmentalbodies. Theinspectionreportisnotdesignedtopredictwhenthingswillbreakdownorcauseproblems.Theinspectionreportisnot designedtoprovideaneducationalwarningoneverysideeffectfromadefectormalfunction. Itisimportanttounderstandthattheobserveddefectmaybeasymptomofagreaterproblemorasolutionmayinvolve troubleshootingasystemandnotjustaddressingtheitemidentifiedinthereport.Thisinspectionreportcannotaddressthose possibilities. Sincerely, MarkGlowczynski
markglowczynski RightatHomeInspectionsandSolutions
Page Number 2
ROOFING
ROOFING LIMITATIONS
Roof Inspected By: Iinspectedtheroofingfromtheground. Limitations: Theentireroofwasfreeandclearformetoinspect. Chimney: Thechimneywasfreeandclearformetoinspect.
ROOFING DESCRIPTIONS
Main Roof: ASPHALT/FIBERGLASSSHINGLES-Thistypeofroofingmaterialhasanestimatedlifespanofapproximately 20years.Someshinglesaremanufacturedthataredesignedtolastupto35years.Itisnotwithinthescopeof thisinspectiontomakethatdetermination. Garage Roof: ASPHALT/FIBERGLASSSHINGLES-Thistypeofroofingmaterialhasanestimatedlifespanofapproximately 20years.Someshinglesaremanufacturedthataredesignedtolastupto35years.Itisnotwithinthescopeof thisinspectiontomakethatdetermination. Chimney: METAL-Metalchimneysneedtoberegularlyinspectedforrustanddamage.Thesedotendtoworkjustfinefor gasappliances.
Page Number 4
EXTERIOR
EXTERIOR LIMITATIONS
Limitations: DISCLAIMER-Theexteriorwasinspectedfromthegroundlevelonly.Itisnotwithinthescopetoclimbthewalls foracloserinspection.ThislimitsmyinspectionandIcannotberesponsibleforanydefectsthatIcannotsee. DISCLAIMER-Storagewasinthegarage.Itisnotwithinthescoperemovethestorageforacloserinspection. ThislimitsmyinspectionandIcannotberesponsibleforanydefectsthatIcannotsee.
EXTERIOR DESCRIPTIONS
Gutters: ALUMINUM-Theguttersaremadeofaluminum.Theseguttersshouldbeinspectedandcleanedatleastoncea year. Downspouts: ALUMINUM-Thedownspoutsaremadeofaluminum.Thedownspoutsshouldbeinspectedandcleanedatleast onceayear. Soffit: WOOD-Thesoffitismadeofwood.Thistypeofmaterialispronetorotandshouldbewellprotectedfromwater damagebykeepingitwellpainted. Fascia: WOOD-Thefasciaismadeofwood.Thistypeofmaterialispronetorotandshouldbewellprotectedfrom waterdamagebykeepingitwellpainted. Windows: Thewindowsaredoublehung. Wall Surfaces: VINYLSIDING-Mostproblemsassociatedwithvinylsidingsareinstallationdefects,ratherthandeficiencieswith thematerialsthemselves.Securingthesidingtootightandalackofmoldingsandtrimpieceswherethesiding buttsothermaterialsorchangesdirection,isoneofthemorecommonproblems.Annualinspections, maintenance,andrepairsasneeded,willhelpextendthelifespanofthevinylsiding. Walkways: CONCRETE-Thewalkwaysaremadeofconcrete. Driveways: ThedrivewayismadeofAsphalt.Thisdrivewayshouldbeseal-coatedatleastonceayearasgeneral maintenance. Retaining Walls: Noretainingwallsarepresentonthisproperty. Garage: Thegarageisatwocarattachedgarage.
Page Number 5
PictureDate:3/30/2010Comments:Replacerottedfaciaboardnearestroofline.
PictureDate:3/30/2010Comments:Recaulkallseamsinfaciaboards.
Page Number 6
PictureDate:3/30/2010Comments:Replacedamagedfaciaboard.
Lot Topography: Theoverallconditionisacceptable. Doors: Theoverallconditionisacceptable. Windows: Theoverallconditionisacceptable. Head Flashings: Theoverallconditionisacceptable. Wall Surfaces: Theoverallconditionisacceptable. Foundation Walls: Theoverallconditionisacceptable.
Page Number 7
PictureDate:3/30/2010Comments:Keepsbushesandallvegetationtrimedaway fromthestructure.
Walkout Basement: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Window Wells: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Walkways: Theoverallconditionisacceptable. Porches: REPAIR or REPLACE-Barewoodisshowing.Inmyopinionthiscanincreasethechancesfordeterioration, rotting,waterleakageandfurtherdamagetothebuilding.Irecommendthatyoucontactaqualifiedcontractorto properlyrepairthiscondition. Driveways: SAFETY-Unevenwalkingsurfacesare presentonthisproperty.Inmyopinionthis isconsideredatriphazardandcanleadto injuryifnotcorrected.Irecommendthatyou contactaqualifiedcontractortocorrectthis situation.Thedrivewayisbuckledwhereit meetsthegaragepad.Althoughtheslopeis stillawayfromthehome,repairshouldme madetomakesureitdoesnotstarttoslope towardthehome.
PictureDate:3/30/2010Comments:Considerrepairofdrivenearthegarage.
Page Number 8
PictureDate:3/30/2010Comments:Replaceweatherstriponoverheaddoor.Repair holesbetweenfoundationanddoorframe.
Door Opener: SAFETY-Theautomaticretractfeatureoftheoverheadgaragedoormotorisnotoperating.Inmyopinionthisis aninjuryhazardanddooroperatorshouldbeadjusted,servicedorotherappropriateactionbyaqualifiedgarage doortechnician. Fire / Gas Proofing: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Carport: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected.
Page Number 9
STRUCTURE
STRUCTURE LIMITATIONS
Limitations: DISCLAIMER-Finishes,insulationand/orstorageisconcealingstructuralcomponents.Icannotberesponsible foranydefectsthatIcannotsee. DISCLAIMER-Iwasnotabletocompletelyinspectthebasementslabduetoaccesslimitations.Icannotbe responsibleforanydefectsthatIcannotsee.
STRUCTURE DESCRIPTIONS
Configuration: Basement CrawlSpace Foundation: Pouredconcrete Post: Thepostsaremadeofsteel. Beams: Steel Floor Construction: Pouredconcreteinbasementarea. WoodJoistinotherareas. Bridging: NotVisible Sub-Flooring: OSB Walls: WoodFrame Roof Framing: Notinspected.
Page Number 10
Page Number 11
ELECTRIC
ELECTRIC LIMITATIONS
Limitations: DISCLAIMER-Iwasunabletocompletelyfollowthegroundwire.IcannotberesponsibleforanydefectsthatI cannotseeorexamine. DISCLAIMER-Concealedelectricalcomponentsnotinspected.IcannotberesponsibleforanydefectsthatI cannotseeorexamine. DISCLAIMER-Maindisconnectcoverwasnotremoved.IcannotberesponsibleforanydefectsthatIcannot seeorexamine. DISCLAIMER-Smokedetectorsarenottestedforoperation. DISCLAIMER-Theelectricalpanelisnotaccessible.Theconditionofthepanelandrelatedinternalwiringis unknown.IcannotberesponsibleforanydefectsthatIcannotsee.
ELECTRIC DESCRIPTIONS
Service Entrance: Underground Copper Service Size: 100amps110/220volts Main Disconnect Location: Basement.Betweenbathandgarage,insidecloset. Main Disconnect Size: 100amps Distribution Panel: Breakers System Grounding: Iwasunabletoverifythegroundingtermination. Distribution Wiring: CopperInsulatedinPlastic Outlets: 15ampoutlets 20ampoutlets GFCIOutlets
Page Number 12
PictureDate:3/30/2010Comments:Replacephonejackplateinbasement.
Switches: Theoverallconditionisacceptable. Lights: Theoverallconditionisacceptable. Ceiling Fans: SAFETY-Exposedwiresarepresentatthe ceilingfans.Thisisanincreasedelectrical shock/firehazard.Appropriatecorrective actionisrecommendedbyaqualified electrician.Thelocationis1stbedroomon leftwhencomingupstairs.Thegreen groundwiredisexposed.
PictureDate:3/30/2010Comments:Allwiringshouldbeproperlyinstalledwithinthe fanshaft.
Page Number 13
Page Number 14
HEATING
HEATING LIMITATIONS
Limitations: DISCLAIMER-Theheatexchangerwasnotvisibleoraccessible.IcannotberesponsibleforanydefectsthatI cannotinspect. DISCLAIMER-Aheatlosscalculationisnotdone.Thisisbeyondthescopeofahomeinspection. DISCLAIMER-Safetydevicesarenottested.IcannotberesponsibleforanydefectsthatIcannotinspect. TRANEModelnumber:AUD100C936H3SerialNumber:M148SK32G
HEATING DESCRIPTIONS
Fuel: Gas Main Gas Shut Off: Themaingasshutoffvalveislocatedontheoutsideofthebuilding. Gas Piping: BlackIron Approximate Age: Thefurnaceisinitsthirdquarterofitsexpectedlife. Failure Probability: Medium Type of Heating System: GasForcedAir Efficiency: Conventional
Page Number 15
PictureDate:3/30/2010Comments:Havefurnacecleanedandservicedbya qualifiedtechnician.
Vent: Theoverallconditionisacceptable. Oil Burner: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Combustion Air: Theoverallconditionisacceptable. Induced Draft Fan: Theoverallconditionisacceptable. Electric Wiring: Theoverallconditionisacceptable.
Page Number 16
COOLING
COOLING LIMITATIONS
Limitations: DISCLAIMER-Thetemperaturewasbelow65degreewithinthepast24hours.Inmyopinion,Imaydamagethe unitifIoperateit.Iamnotoperatingthisunit.IcannotberesponsibleforanydefectsthatIcannotinspect. DISCLAIMER-Aheatlossorheatgaincalculationisnotdone.Thisisbeyondthescopeofahomeinspection. DISCLAIMER-Safetydevicesarenottested.IcannotberesponsibleforanydefectsthatIcannotinspect. DISCLAIMER-Theoutdoortemperatureis/orhasbeenconsistentlylowerthan65degrees.Itisagenerally recognizedpracticenottotesta/csystemswhentheoutdoortemperatureislowerthan65degreessincethiscan damagethea/csystem.Duetothetemperature,thea/csystemwasnottestedanditsconditionandoperating conditionisunknown.
COOLING DESCRIPTIONS
Approximate Age: Theunitisinitsthirdquarterofitsexpectedlifespan Cooling Capacity: 2.5Ton Type of System: AirtoAir YORKModelNumber:H2RA030S06ASerialNumber:couldnotsee
PictureDate:3/30/2010Comments:Topgrateoverfanisrusted.
Page Number 17
Page Number 18
PLUMBING
PLUMBING LIMITATIONS
Limitations: DISCLAIMER-Theoverflowdevicesarenottestedaspartofthehomeinspection.Theseareconsidered emergencydevicestoreduceoverflowdamage.Sincetheydon'tgetused,theyoftendryupandhaveminor leaks.SinceIamawareofthiscommonproblemandIhavenowishtodamagetheproperty,Idonottestthese devices.Icannotandwillnotbeheldliableshouldadefectexisthere. DISCLAIMER-Thewatertreatmentdevicesarenottestedaspartofthehomeinspection.Icannotandwillnot beheldliableshouldadefectexisthere. DISCLAIMER-Theconcealedplumbingisnotpartofthehomeinspection.SinceIcannotseetheseitems,I cannotandwillnotbeheldliableshouldadefectexist. DISCLAIMER-Thewaterheaterisinstalledwithpoorclearancesoraccessibility.Thismakesinspectiondifficult orlimitedanditsfullconditionisunknown.Itismyopinionthattheinadequateaccessmayresultintechniciansto notbeabletoproperlyserviceormaintainthehotwatersystem. DISCLAIMER-Nowatervalveistestedduringtheinspection.Valvesaredesignedforemergencyuseand repairsonly.Thesevalveshaveahightendencytoleakwhenturned.Icannotandwillnotberesponsibleforany defectsthatarepresent. DISCLAIMER-Theshowerwasnottested.IcannotandwillnotbeheldresponsibleforanyitemsthatIdonot inspect.
PLUMBING DESCRIPTIONS
Water Heater: ConventionalGasFired AOSMITHModelnumber:FSG40240SerialNumber:GF973634189S19 Supply Piping: Copper Service Piping Into House: Copper Waste Piping: Unknown Location of Main Shut Off: CrawlSpace
Page Number 19
PictureDate:3/30/2010
Laundry Tub: Theoverallconditionisacceptable. Service Piping Into House: DISCLAIMER-Thiscomponentwasunabletobeinspected. Water Flow (Functional Flow): Theoverallconditionisacceptable. Sump Pump: Theoverallconditionisacceptable. INFORMATION-Thesumppumpdoesnothaveabatterybackup.Inmyopinionthisisanincreasedpotential forflooding.Installationofabatterybackupsumppumpbyaqualifiedplumberorfloodcontroltechnicianis recommended. Toilets: Theoverallconditionisacceptable. Waste Piping: DISCLAIMER-Thiscomponentwasunabletobeinspected. Venting: Theoverallconditionisacceptable. Water Heater: REPAIR or REPLACE-Basedonitsage,itismyopinionthatthewaterheaterisatorbeyonditsusefullifeand shouldbereplaced. Supply Piping: Theoverallconditionisacceptable. Outdoor Spigots: Theoverallconditionisacceptable.
Page Number 20
PictureDate:3/30/2010Comments:Recaulkalongbottomedgeoftub.
Page Number 21
INTERIOR
INTERIOR LIMITATIONS
Limitations: DISCLAIMER-Nocommentsaremadeoncosmeticitems. DISCLAIMER-Thedraintileisnotvisible.IcannotberesponsibleforitemsthatIcannotsee. DISCLAIMER-Iamunabletoseetheinsideoftheflue.IcannotberesponsibleforitemsthatIcannotsee.
INTERIOR DESCRIPTIONS
Major Ceiling Finishes: Drywall Exterior Doors: STEEL-Theexteriordoorsaremadeofsteel. SlidingGlass Major Floor Finishes: Carpeting ResilientTile Major Wall Finishes: Drywall Paneling Interior Doors: WOOD-Theinteriordoorsarehollowcorewood.
PictureDate:3/30/2010Comments:Smallholeinmasterbedroomscreens.
Page Number 22
Page Number 23
INSULATION
INSULATION LIMITATIONS
Limitations: DISCLAIMER-Icannotconfirmthecontinuityoftheair/vaporbarrier.Icannotberesponsibleforanydefects thatIcannotinspect. DISCLAIMER-Theatticwasinspectedfromthescuttleopeningonly.Theviewwithintheatticislimitedtothe areavisiblefromthescuttleonly.Icannotberesponsiblefordefectsthatarenotvisiblefromthisarea. DISCLAIMER-Icannotgainaccesstotheroofspacefrommain/masterbath.Icannotberesponsibleforany defectsthatIcannotinspect. DISCLAIMER-Icannotgainaccesstothewallspace.IcannotberesponsibleforanydefectsthatIcannot inspect. DISCLAIMER-Icannotconfirmthecontinuityoftheair/vaporbarrier.Icannotberesponsibleforanydefectsthat Icannotinspect.
INSULATION DESCRIPTIONS
Vapor Barrier: Plastic Roof Ventilation: RoofVents Main Attic: Fiberglass Second Attic: Icouldnotgainaccesstoareaoverkitchen.
PictureDate:3/30/2010Comments:Couldnotgainaccessto atticoverkitchen.
Page Number 24
Page Number 25
APPLIANCES
APPLIANCES LIMITATIONS
Limitations: DISCLAIMER-Theappliancesarenottestedforacompletecycleorunderrealloadapplications.Theinspection ofappliancesislimitedtobasicresponseofbasicfeaturesonlyandtolistenforunusualnoises.Howwellthe appliancewillperformanceunderrealconditionsisunknown.
APPLIANCES DESCRIPTIONS
Range: Therangeoperateswithgas. Oven: Theovenoperateswithgas.
Page Number 26
ENVIRONMENTAL
ENVIRONMENTAL INSPECTABLE ITEMS
Asbestos: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Lead Pipes: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Lead Paint: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Mice: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Radon: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Termite: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Carpenter Ant: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Animal: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected. Mold: DISCLAIMER-Thiscomponentwasnotpresentorabletobeinspected.
Page Number 27