RELEASE NOTES for INSITE 7.5


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Note: If it is difficult to read this document with Microsoft notepad, click
on "Word Wrap" under the "Format" menu item or 'maximize' the Notepad
window. To print this and have the tables in a valid format set the
page margins to 0.25.
CAUTION: Please verify that the Calibration you select to download to an ECM
is appropriate for that specific ECM. Permanent damage could occur if
incorrect calibrations are downloaded.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Contents
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
A.
B.
C.
D.
E.
F.
G.
H.

Issues with INSITE 7.5


Issues with ECM Applications
Datalink Adapters INLINE, INLINE I and INLINE II, RP1210A
Datalink Adapter Compatibility Matrix
Version Compatibility
Special Issues
Suggestions and Tips
Saving Data from previous versions of INSITE

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
A. Issues with INSITE 7.5
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
PCID's
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- It is becoming common for INSITE to be installed and registered with an
Administrator account, and then used with a Limited User account. On some
computers, INSITE does not have access to the same security settings on
Limited User accounts as it would on Administrator accounts. This causes
a different PCID to be displayed for the Limited User account after INSITE
has been registered with the PCID displayed for an Administrator account.
It is recommended after installation to register the INSITE PCID displayed when
logging into the Limited User account.
- For Calibration Authorization passwords contact your Distributor with the
INSITE 7.5 PCID.
- New users can enter both the Basic and Functional Password when first opening
INSITE . If the Basic is entered on the "New Functionality Password" window,
INSITE will open in Read Only. The Functionality Password will have to be
entered under the Tools > Options > Security window. (DB_G00149670)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Installation
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- When installing Chinese version of INSITE on Windows XP, East Asian Languages

Option in the Regional Settings must be selected in order for the Characters
to appear correctly.
- INSITE

7.5 does not support Windows 95, 98, 98SE, ME, NT or 2000.

- Windows XP, Windows Vista or Windows 7 must have full administrative


privileges to install. After installation, INSITE can be run with User
privileges.
- Refer to the following table for the hard drive space required for the
installation of INSITE 7.5. This is based on the assumption of "C" drive
being the drive on which the Operating System is installed.

+----------------------------+----------------------------+
|Installing on the "C" drive |Installing on the "D" drive |
|
|
|
+------------------+----------------------------+----------------------------+
|
|
|
|
|
|
|
|
| Space required |
C:450 MB
|
C: 30 MB
|
| at the time of |
|
|
| installation
|
D:N/A
|
D: 400 MB
|
|
|
|
|
|
|
|
|
+------------------+----------------------------+----------------------------+

- It is recommended that you always reboot your PC after installing software.


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Connections
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Error Messages for communication failures:
- Error 5200: Indicates communication loss between computer and the data
link
adapter.
- Error 5201: Indicates communication loss between the datalink adapter
and
the ECM.
- Error 5202: Indicates no communication could be established between th
e
datalink adapter and the computer.
- Error 5204: Indicates no communication could be established between th
e
datalink adapter and the ECM.
- Verify that the infrared port is disabled so the serial port is only being use
d
for ECM communications.
- If you have the Palm Pilot Hot Sync Manager on a PC that only has one serial p
ort,
you must disable the Hot Sync Manager before connecting to an ECM.

- An Internet connection is required before selecting the "http://www.cummins.co


m"
or "http://insite.cummins.com" link from the Help > About INSITE dialog.
- Auto Configure and "Datalink Adapter Connection Test" does not find the adapte
r
when connected to a multi-module system.
Work Around: Manually configure the Datalink adapter connection. (DB_G001514
41)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Advanced ECM Data
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- To print Advanced ECM Data Views, right-click in the right pane and
click on Print.
- If the display becomes distorted or cannot be completely viewed, close the
Advanced ECM Data View and then reopen it. Resizing can cause the views to
become distorted.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Calibrations
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Automotive applications will have a default setting of "ON" for the Save and
Restore option in the Calibration Download dialog.
- Industrial applications will have a Default Setting of "OFF" for the Save and
Restore option in the Calibration Download dialog.
- When performing a Calibration Download, the "Save and Restore" option may be
grayed out for some applications.
- To decrease calibration download times please make sure all applications other
than INSITE are closed. Always use the J1939 protocol and engine connector
when available.
- Computers with less than the minimum recommended hardware requirements will ha
ve
an extended Calibration Download time. Make sure that screen savers and suspen
d
modes are disabled.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Display & Graphics
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- The use of Large Toolbar buttons will not display all icons on the toolbar.
Work Around: Under Tools > Options > General, select Small Buttons in the
Display Options. (DB_G00150835)
- Use of Extended Desktop feature in Windows XP or Vista is not supported by INS
ITE 7.5.
- To Disable the "Display Feature Names" option for the view bar, the checkbox
in Tools/Options/General/Viewbar/Display Feature Names must be unchecked.
- If your PC monitor display is set to "Large Fonts", not all information in INS
ITE

may be displayed. It is recommended to use small fonts.


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ECM Diagnostic Tests
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- If the display becomes distorted or cannot be completely viewed, close the
ECM Diagnostic Tests View and then reopen it. Resizing may cause the view to
become distorted.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Fault Codes
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- The MIL Lamp Status is not displayed when printing the Image Fault Codes in To
ol
Display Format.
Work Around: Print the Image Fault COdes in Text Only Format or connect to th
e
image, open Fault Codes and select the Print icon. (DB_G00169914)
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Printing
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- When using print preview use the tool bar magnifying glass to display the
text in a larger view.
- The Print options will be disabled when no printers are available. This
includes the Page Setup, Print and Print Preview options.
Work around: Setup/install a printer on the PC and retry the INSITE print
selection.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Simulators
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Values shown in simulator do not reflect real values that would be seen by a u
ser
when connected to an engine.
- When creating a Work Order on the QSK19G/45G/60G, QSV81/91 simulator, Error 10
411
is displayed and a work order is not completed. (DB_G00151367)
- The Aftertreatment High NOx Reset Test on the ISL8.9 CM2150 SN(Euro 4.5),
ISL8.9 CM2150 SN(Euro 4.5), and ISX 11.9/15 CM2250 simulators does not run.
After clicking the Start button, "Error Number 40203 An internal error has
occurred in the INSITE program" is displayed. (DB_G00148885)
- The Power Generation Tunning Test on QSK38 CM850/CM2150 and QSK50/60 CM850/CM2
150
Power Gen Simulators does not run. After clicking the Start button,
"Error Number 40508 An internal error has occurred in the INSITE program" is
displayed. (DB_G00151368)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Trip Information
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- When resetting Trip Information be sure to key off for 30 seconds before
continuing. The ECM may have an invalid foot print if the key is not
switched off for the required amount of time.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Work Orders/ECM Images/Templates
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Double clicking on an image file (.eif format) will open INSITE , import the ima
ge
and automatically connect to this image.
- Double clicking on the converted image files (.csv format) will not open them
with the correct format in Microsoft Excel.
Work around:
Follow the steps below to open a converted (.csv format) image file in Excel:
- Open Microsoft Excel
- Click on File -> Open
- Change the Files of type field to "All Files(*.*)" or "Text Files (*.
csv)
- Select C:\Intelect\INSITE\Export\desiredimage.csv
- The "Text Import Wizard" will open
- In Step 1 of the wizard, make sure the "Delimited" option is selected
and
click "Next"
- In step 2 of the wizard, uncheck the "Tab" box and check the "Comma"
box
and click "Next"
- In step 3 of the wizard, click on "Finish"
- Format columns as desired
- When upgrading to INSITE 7.5 from any version of INSITE , the following files
need to be backed up:
- C:\Intelect\INSITE\WorkOrders
- C:\Intelect\INSITE\UserSettings\data.wo
- When using templates it is advised to verify the first template sent to the ta
rget
vehicle. This helps ensure the template configuration is correct for subsequen
t
vehicles.
- When using templates verify that the ECM code is compatible or the same.
- When naming images and templates, special characters cannot be used
(i.e. & ^, etc).
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
B. Issues with ECM Applications
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- User Activated Data Logger (UADL) is not supported.


~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CELECT
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- When calibrating a CELECT, you will need the ECM serial number and the SC opti
on
that is displayed in INSITE to receive calibration authorization password(s)
from QuickServe Online. INSITE only displays the SC option and to get a valid
password the SC Option and ECM Serial Number needs to be entered into the webs
ite.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ISBe4 (4 and 6 cylinder) CM850
ISLe4 (6 cylinder) CM850
ISX/ISZ13 CM2150 SN
ISF2.8 CM2220 AN
ISF3.8 CM2220 AN
ISB
ISL
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- High NOx Reset test
This test cannot be run more than once on a single key cycle.
Work Around. If this test needs to be performed more than once, key off befo
re
restarting the test.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Signature/ISX - CM570
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Features and Parameters
- J1939 Multiplexing
If the "J1939 Multiplexing" feature and its sub-features are enabled,
they cannot all be disabled at the same time and sent to the ECM,
INSITE displays an error dialog stating that "The write to ECM failed
for the requested parameters."
- Engine Brake Control
If a phase 8 calibration is currently in the ECM, the Engine Brake
Delay Time value might be set to zero regardless of the actual value
entered for this parameter in the Features and Parameters.
Work around:
Check the value for the Calibration Software Phase in INSITE (can be
found in Features & Parameters/System ID & Dataplate/Calibration
Information). If it starts with 08, then download the latest version o
f
the ECM Code to resolve this issue.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
ISX - CM870
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

- The "Injector Check Valve Diagnostics Test" might not run for some earlier ECM
code phases on the ISX - CM870 ECMs. Please refer to the table below
for more details.
+----------------------------+------------------------------+
+----------------------------+------------------------------+
|
ECM Code Phase
| Test Status in INSITE 7.5
|
+----------------------------+------------------------------+
+----------------------------+------------------------------+
|
|
|
| Phase 5.4.6.02 and prior |
Test will not run
|
|
|
|
+----------------------------+------------------------------+
|
|
|
| Phase 5.4.7.11 and post |
Test will run
|
|
|
|
+----------------------------+------------------------------+
|
|
|
| Phase 6.5.1.01 and prior |
Test will not run
|
|
|
|
+----------------------------+------------------------------+
|
|
|
| Phase 6.5.2.0x and post |
Test will run
|
|
|
|
+----------------------------+------------------------------+
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CELECT Plus
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- INSITE ReCon ECM Procedure:
CAUTION:
To Calibrate this ECM, use the following steps:
1.
2.
3.
4.
5.
6.
7.
8.
9.

Hook up battery power


Turn key switch ON for 10 seconds
Turn key switch OFF
Launch INSITE
Connect
Click OK to ROM boot message
Select Calibration Selection
Choose the appropriate calibration code and transfer to ECM
Turn key switch ON when INSITE prompts
(E03016)

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
QSK19/45/60-CM500
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- When calibrating a QSK19/45/60-CM500 ECM using an INLINE II, 4 or 5,
avoid using a connection with "Auto Detect" as the calibration might fail.
Work around: Use an INLINE II, 4 or 5 connection that uses J1587/J1708
instead of Auto Detect.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
QSM 11
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Calibration Selection

When calibrating QSM11 engines utilizing Multiple Unit Synchronization,


J1708 protocol must be used. The calibration will not download to the ECM
successfully if J1939 protocol is used. If both J1708 and J1939 protocols
are available on the Datalink, an INLINE or INLINE I must be used to access
the J1708 protocol or use an INLINE II, 4 or 5 connection that uses J1587/J170
8
instead of Auto Detect.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
C. Datalink Adapters INLINE, INLINE I, INLINE II and RP1210A
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
The INLINE II adapter has become obsolete. It can be used with INSITE , but technic
al
support for this adapter is not available.
- The INLINE II Adapter must contain Version 9.28 or greater firmware to be
compatible with INSITE 7.5. You must use the Reflash program that was
installed with INSITE "INLINE Reflash".
- For instructions on how to Reflash your INLINE II Adapter refer to the help
button in the INLINE Reflash program.
- INSITE 7.5 supports all the Cummins Service Products INLINE, INLINE I,
INLINE II and RP1210A (INLINE 4/5) Adapters.
The INLINE and INLINE I Adapters support the J1587/J1708 protocol and
INLINE II and RP1210A (INLINE 4/5) Adapters currently supports J1587/J1708
and J1939 protocol for most ECM applications.
- The latest Inline 4/5 drivers will automatically be installed/upgraded with
the installation of INSITE 7.5. The drivers can also be downloaded from
http://inline.cummins.com
After installing the latest drivers, be sure to reflash the adapter to the
latest firmware.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
D. Datalink Adapter Compatibility Matrix
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
+----------------------------------------------+
|
INSITE 7.5
|
+-------+---------+-------------+--------------+
|INLINE |INLINE I | INLINE II* | INLINE 4/5 |
|
|
|
| (RP1210A) |
+---------------+-------+---------+-------------+--------------+
| Program
| J1587 | J1587 |J1587 |J1939 | J1587| J1939 |
|
| J1708 | J1708 |J1708 |
| J1708|
|
+---------------+-------+---------+-------------+--------------+
|480 C-E
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|B5.9 Gas
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|L10G/C8.3G
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|C Gas Plus / |
|
|
|
|
|
|
|B Gas Plus
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+

|L Gas Plus
|
|
|
|
|
|
|
|
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISB5.9 G CM2180|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISL G CM2180 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|CELECT
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|CELECT Plus
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|CELECT PlusInd | X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|CENTINEL
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|CENTRY
| X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|Gas Compression|
|
|
|
|
|
|
|GTA/KTA
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|Gas CENSE
|
|
|
|
|
|
|
|QSV81/91
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|B3.9/5.9/C8.3 |
|
|
|
|
|
|
|CM2150
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISB
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------|
|ISB Chrysler |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISBe/ISBe4
|
|
|
|
|
|
|
|4 & 6 Cylinder | X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISBe4.5/ISBe5 |
|
|
|
|
|
|
|- CM2150
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISC/ISL
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISC/Transit
|
|
|
|
|
|
|
|Bus ISL8.3|
|
|
|
|
|
|
|CM850
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISB6.7 CM2250 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISC8.3 CM2250 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISB/L-CM850
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISL8.9 CM2150 SN
|
|
|
|
|
|
| (Euro 4.5/5) |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISL9 CM2250
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISF2.8CM2220 AN|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISF2.8CM2220IAN|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISF3.8CM2220 AN|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISF3.8CM2220IAN|
|
|
| X |
| X |

+---------------+-------+---------+------+------+------+-------+
|ISLe4.5/ISLe5 |
|
|
|
|
|
|
|- CM2150
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISM
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISM-CM870/875 | X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|ISM-CM876
|
|
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|ISM11-CM876 SN |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISX-CM871
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISX/ISZ13
|
|
|
|
|
|
|
|- CM2150 SN
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|ISX11.9/15
|
|
|
|
|
|
|
|- CM2250
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|Signature/ISX | X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|Signature/ISX |
|
|
|
|
|
|
| - CM870
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|PIM
| X |
X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSB
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSC8.3/QSL9
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSK19/45/60/78 | X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|QSK19/23-CM500 | X | X
| X |
| X |
|
+---------------+-------+---------+------+------+------+-------+
|QSM11
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSX15
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSX15 CM2250ECF|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QST30
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSK19G/45G/60G |
|
|
|
|
|
|
|QSV81/91
| X | X
| X | X | X | X |
+---------------+-------+---------+------+------+------+-------+
|QSK19/23/38/50 |
|
|
|
|
|
|
|/60/78-CM850 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSB/C/L-CM850 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSB5/7-CM850 PG|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSB3.3-CM2150 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSB4.5/6.7
|
|
|
|
|
|
|
|CM2250
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSL 9 CM2250 |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+

|QSK23/60/78
|
|
|
|
|
|
|
|CM850 PG
|
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSL9-CM850 PG |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QSM11-CM876 PG |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
|QST30-CM850 PG |
|
|
| X |
| X |
+---------------+-------+---------+------+------+------+-------+
* NOte: The INLINE II adapter has become obsolete. It can be used with INSITE ,
but technical support for this adapter is not available.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Datalink Adapter Issues
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Do not substitute cables, except as indicated in the INLINE 4/5 Product
Announcement Bulletin.
- Do not use an extension cable on the Datalink side of the INLINE II adapter.
- Incompatible cables may damage the INLINE, INLINE I INLINE II and/or INLINE 4/
5
adapter or personal computer and will void warranty.
- Incompatible cables may cause communication issues with INSITE .
- INLINE II or INLINE 4/5 adapter may intermittently lose communication. If you
r
Datalink adapter has communication problems, disconnect power from the adapter
for 5 seconds and then reconnect. The INSITE program does not need to be
shutdown.
- There is feature under Tools - Reset Datalink Adapter that will correct some
software communication errors with the INLINE II and INLINE 4/5.
- The main harness (backbone) has a maximum overall length of 40 meters.
- A J1939 stub, which can be a connection point for ECM's and/or the
INLINE II or INLINE 4/5 Datalink adapter, cannot exceed a maximum length of 1
meter.
- At each end of the backbone harness is a terminating resistor with a
nominal resistance of 120 Ohms, it will measure 60 Ohms when you measure
across the Datalink.
- The INLINE II and INLINE 4/5 Adapters should be connected to a continuous
battery power supply. When making adjustments with INSITE , including calibrati
on
download, the operator will be asked to switch the key off for 30 seconds.
If the adapter is getting its power from a power source dependent on the key
switch status, such as the lighter adapter inside the cab, the Adapter will lo
se
power, which will result in INSITE losing connection to the ECM. This will
require the operator to reconnect to the ECM and the adjustments might not
have been saved.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
E. Version Compatibility

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
INSITE Software and Operating System Compatibility:
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- INSITE 7.5 is compatible with the following operating systems:
Windows XP SP3, Windows Vista, and Windows 7. Both 32-bit and 64-bit
versions are supported.
- Contact the local Cummins Distributor to register your new INSITE
Service Tool and receive a password.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
F. Special Issues
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Power Savers
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Turn off any power saver features when communicating with an ECM,
especially when downloading a calibration to an ECM. These commands
require the computer to communicate with the ECM, but do not require
you to interact with the computer. As a result, the power saver does
not recognize that a command is in progress and automatically turns
off the computer. This may disable the COM port, hard drive and other
hardware required for the calibration download process.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
G. Suggestions and Tips
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Do not turn off the PC while INSITE is running. Exit INSITE before
turning off the computer. Disk and database corruption can occur
if you do not exit INSITE before turning off the computer.
- If the PC CMOS battery is not working, please make sure you reset
the PC date and time and restart the computer before you attempt to open
INSITE .
- To back up all Work Orders and Images with INSITE 7.5, select the
"Export All" from the right-click menu while highlighting any Image.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
H. Saving Data From Previous Versions of INSITE
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- ECM Templates from earlier versions of INSITE 6.3A, 6.4, and 6.5 cannot
be used with INSITE 7.5. They can be printed.
- ECM Templates from INSITE

6.5.1, 6.5.2, 7.0 and 7.0 FP1/FP2 for the ISB CM2150,

ISC CM2150 and ISL CM2150 cannot be used with INSITE 7.5. They can be printed.
All other engine's templates can be used with INSITE 7.5.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
JRE Created: INSITE 7.5 - April 2011