Vous êtes sur la page 1sur 4

Troubleshooting Steps

1. After receiving the call from NOC, First confirm the alarms which came before OML fault alarm & if there is some power/Tx alarm, do the proceedings accordingly. 2. If NOC informed you that multiple sites are down around the same time, then try to find the common thing among them. Try to check the common route between them or any Hub site or any specific lease line/MW link involved. 3. After reaching on site, check all the Power breakers. 4. Check the IDU & its working condition physically. 5. Check BTS & check all the LEDs physically specially LIU0 on GTMU. 6. Give the Internal loop from DDF Krone towards the BTS & check whether the status of LIU0 is normal or not, If it is normal then GTMU is most probably OK. LIU0 will be off when E1 is normal. LIU0 will be on when E1 is break. LIU0 will be blinking if only Tx is up & Rx is down (check patching on DDF) 7. Check the patching status through LED & try to re punch the DDF Krone & check with NOC again. 8. Try to give the loop towards the BSC & if it is not ok then move to far end to check the loop from there & continue it till BSC, till you find the missing node. 9. During all this troubleshooting, stay in touch with Front office. During all this, if you think there is a problem in GTMU then replace it & if the problem is resolved then again replace the new GTMU with old one to confirm that old GTMU is faulty. Try to give hard reset to the BTS in b/w this troubleshooting.

BBU Hardware GTMU Board

The GSM Transmission, Timing, and Management Unit for BBU (GTMU)

controls and manages the entire BTS in GSM mode. It provides interfaces
related to the reference clock, power monitoring, OM, and external alarm collection.

Functions:

Controlling, maintaining, and operating the BTS. Providing fault management, configuration management, performance management, and security management. Monitoring the fan module and the power supply module. Providing four routes of E1 transmission. Providing CPRI ports for the communication with the RF modules. Distributing and managing BTS clock signals.

Providing the Ethernet port for local maintenance.


Providing clock output for testing.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 1

BBU Hardware GTMU Board

Ports on the GTMU panel:


Board Port CPRI0 CPRI5 ETH Connector Type Description Ports for the communication between the BBU and the RF SPF module; support input and output of the optical and electrical signal. RJ45 Port for local maintenance and commissioning Connects the BBU to a routing device in the equipment FE0 RJ45 room through the Ethernet cable to transmit network

information.
GTMU Connects the BBU to a routing device in the equipment FE1 DLC room through the optical cable to transmit network information. USB TST USB USB Enables the automatic software upgrade from a USB disk. Provides a reference clock for the tester. Provides the input and output of the four E1/T1 signals E1/T1 DB26 female between the GTMU and the UELP or between the GTMU and the BSC. HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 31

BBU Hardware GTMU Board

LEDs on the GTMU:


Color Status ON OFF Description The board is faulty. No power supply is available or the board is faulty. The board is operational.

LED

RUN

Green

ON for 1s and OFF for 1s

ON for 2s and OFF for 2s


ON for 0.125s and OFF for 0.125s ON ALM Red OFF ON ACT Green OFF ON LIU0~LIU3 Green ON for 0.125s and OFF for 0.125s OFF Green CPRI0~CPRI5 Red ON ON

The OML link is abnormal.


The board is loading software. A fault occurs in the running board. No alarm is generated. The board is operational. The board is faulty. This link is not used. A remote E1/T1 alarm is generated. This link is operational. The CPRI link is normal. The reception of the optical module is abnormal and an alarm is generated.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 32

BBU Hardware GTMU Board

DIP Switches:

DIP Status DIP Switch 1 ON SW1 OFF ON ON 2 The E1 impedance is set to 75 ohms. The E1 impedance is set to 120 ohms. Description

ON

OFF

The T1 impedance is set to 100 ohms.

DIP Status DIP Switch 1 2 3 4 Description When four 75- ohm E1 links are faulty, all the

ON
SW2 OFF

ON

ON

ON

DIP bits of S2 should be set to ON (unbalanced mode) so that the Faults are rectified.

OFF

OFF

OFF

All the DIP bits of S2 are set to OFF (balanced mode) by default in all modes.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 33

BBU Hardware GTMU Board

DIP Switches:

DIP Status
DIP Switch 1 2 3 4 Description

ON SW4 OFF

ON

ON

ON

The E1 link can be bypassed.

OFF

OFF

OFF

The E1 link cannot be bypassed.

DIP Switch

DIP Status 1 ON OFF ON ON ON OFF OFF ON ON 2 ON ON ON ON OFF OFF 3 ON OFF OFF OFF OFF OFF 4

Description The E1 link cannot be bypassed. The E1 link of the Level 1 cascaded BTS can be bypassed. The E1 link of the Level 2 cascaded BTS can be bypassed. The E1 link of the Level 3 cascaded BTS can be bypassed. The E1 link of the Level 4 cascaded BTS can be bypassed. The E1 link of the Level 5 cascaded BTS can be bypassed.

SW5 OFF ON OFF

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 34