Vous êtes sur la page 1sur 8

Waste-Oil Boilers

At EnergyLogic, a pioneer in waste-oil technology since 1984, were committed to value and making products that combine only the highest quality, best performance, least amount of maintenance and lowest cost of ownership for our customers. With a patent on every major component and an innovation on every industry standard, our heaters and boilers outperform and outlast the competition. When you choose EnergyLogic, youll not only get a product that operates as reliably as conventional heaters, but a product that requires minimal routine maintenance and is built to last.

ASME CERTIFIED VESSEL CONSTRUCTION


Heavy carbon-steel construction. Stronger & more efficient than cast-iron boilers. More corrosion resistant. 80% efficiency rating.

STEADYFLO FUEL PUMP SYSTEM P


No manual adjustments required, regardless of viscosity. Ensures accurate fuel volume delivery.

DOMESTIC HOT WATER COIL


Provides hot water for rest rooms, showers, dishwashers, etc.

REMOVABLE REAR ACCESS PANEL


Rear panel access for easy, straight-thru cleaning.

WET FLOOR BASED HEAT EXCHANGER


Heat exchanger is totally water cooled. Prevents hot spots and metal deterioration.

SMALL FOOTPRINT
Saves space. Makes installation simple.

ACCUTEMP P PRE-HEATER
The patented pre-heater heats the oil before it enters the nozzle block, preventing residue build-up. The solid state technology allows for a more precise heating control which results in more efficient combustion.

FLAME P RETENTION HEAD


Ensures a controlled flame and better combustion.

INTEGRATED AIR COMPRESSOR


Makes the heater a truly self-contained unit, not relying upon your shop air.

CALL YOUR LOCAL DEALER FOR A LIST OF REFERENCES AND SATISFIED CLIENTS

A COMPLETE PACKAGE
Each EnergyLogic Boiler includes: SteadyFlo Fuel Pump System P .......................... Standard Barometric Damper .............................................. Standard AccuTemp Pre-Heater .......................................... Standard P

P Indicates Patented Design

  

Integrated Air Compressor ................................ Standard Draft Gauge ............................................................ Standard Hour Meter .............................................................. Standard

  

BoilerSpecSheet

11/29/06

1:08 PM

Page 2

EL-200 B

EL-375 B

EL-500 B

Used-Oil Boiler Model 200


COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil Precision metering over a wide range of fuels UL listed system 1.4 gallons / 5.3 liters per hour 200,000 BTU / 58.3 kW per hour 230F / 110C 4.0 gallons / 15 liters per minute at 100F / 37.8C temp rise Wet floor based design 30 gallons / 113.56 liters 45H x 32W x 50D / 114cm H x 82cm W x 127 cm D Analog (Clocks only actual burn time) 8 / 20.32 cm diameter

Used-Oil Boiler Model 375


COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil Precision metering over a wide range of fuels UL listed system 2.7 gallons/10.2 liters per hour 375,000 BTU / 109 kW per hour 230F / 110C 6.0 gallons / 22 liters per minute at 100F / 37.8C temp rise Wet floor based design 43 gallons/162.75 liters 50H x 28W x 54.25D / 127 cm H x 71 cm W x 138 cm D Analog (Clocks only actual burn time) 8 / 20.32 cm diameter

Used-Oil Boiler Model 500


COMMONLY USED FUELS Used crankcase oils, ATF, hydraulic fluid, No. 2 fuel oil and up to 90W gear oil Precision metering over a wide range of fuels UL listed system 3.6 gallons / 13.6 liters per hour 499,000 BTU / 146 kW per hour 230F / 110C 8.0 gallons / 30 liters per minute at 100F / 37.8C temp rise Wet floor based design 52 gallons / 196.84 liters 45H x 32W x 68D / 114cm H x 82cm W x 173 cm D Analog (Clocks only actual burn time) 10 / 25.4 cm diameter

FUEL METERING PUMP UL CERTIFICATION FUEL FLOW RATE BTU INPUT WATER OUTPUT TEMPERATURE (MAX.) DOMESTIC HOT WATER OUTPUT HEAT EXCHANGER BOILER CAPACITY SYSTEM DIMENSIONS HOUR METER EXHAUST FLUE DIAMETER

FUEL METERING PUMP UL CERTIFICATION FUEL FLOW RATE BTU INPUT WATER OUTPUT TEMPERATURE (MAX.) DOMESTIC HOT WATER OUTPUT HEAT EXCHANGER BOILER CAPACITY SYSTEM DIMENSIONS HOUR METER EXHAUST FLUE DIAMETER

FUEL METERING PUMP UL CERTIFICATION FUEL FLOW RATE BTU INPUT WATER OUTPUT TEMPERATURE (MAX.) DOMESTIC HOT WATER OUTPUT HEAT EXCHANGER BOILER CAPACITY SYSTEM DIMENSIONS HOUR METER EXHAUST FLUE DIAMETER

FUEL TANK (sold separately) Standard Tank Single wall, 250 gallon / 946.35 liter workbench Optional Tank Double wall workbench available ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit SHIPPING WEIGHT System with Standard Tank System without Tank STANDARD FEATURES: OPTIONAL FEATURES: 1237 lbs / 561 kg 812 lbs / 369 kg Integrated Air Compressor, Barometric Damper, Draft Gauge Various Size Fuel Tanks

FUEL TANK (sold separately) Single wall, 250 gallon / Standard Tank 946.35 liter workbench Optional Tank Double wall workbench available ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit SHIPPING WEIGHT System with Standard Tank System without Tank STANDARD FEATURES: OPTIONAL FEATURES: 1450 lbs / 656 kg 1025 lbs / 464 kg Integrated Air Compressor, Barometric Damper, Draft Gauge Various Size Fuel Tanks

FUEL TANK (sold separately) Single wall, 250 gallon / Standard Tank 946.35 liter workbench Optional Tank Double wall workbench available ELECTRICAL REQUIREMENTS 115 VAC, 60 Hz, 20 amps dedicated circuit SHIPPING WEIGHT System with Standard Tank System without Tank STANDARD FEATURES: OPTIONAL FEATURES: 1550 lbs / 703 kg 1125 lbs / 510 kg Integrated Air Compressor, Barometric Damper, Draft Gauge Various Size Fuel Tanks (sold separately)

BOILER APPLICATIONS
In-Floor Radiant Heating Car and Truck Washes Paint Booths Ice Prevention Heating Make-Up Air Evaporation Hot Water Potable Hot Water Dishwashers Truckstops Supplement to HVAC Systems

STORAGE TANK
Optional UL-listed 250 gallon workbench storage tank.
ASME Certified, meets NFPA standards

THE INDUSTRYS MOST COMPREHENSIVE WARRANTY*


Parts energylogic Industry Average 3 years 1 year
* North American Warranty

Heat Exchanger 10 years* 10 years**

For more information about Energ yLog ic products please visit w w w.energ ylog ic.com or call 1-8 00-311-8 828.

Advantages of the Black Gold Boiler

Proven burner performance; generally all that is required is supply of burnable fuel, occasional fuel filter change, ash cleanout every 500 hours & an annual preventative maintenance. Serviceability, Simple to maintain Swing-away burner door assembly for easy access to chamber and boiler tubes Straight through ash clean out, 10 minutes instead of half a day Compact boiler size per BTU output - Convenient to locate in separate boiler/furnace room 32" width 50" length 40" height or attached /detached shelter. Flexible hydronic heat, routing throughout various rooms & adjacent buildings. Quiet, versatile heat. A competitive price with more features Steel boiler to eliminate rusting and better heat conductivity than cast iron Burner has own integral air compressor. No need to use shop air when unattended. Fuel Metering Pump that automatically handles different viscosity's of fuel, no regulators to adjust or clean. This means less ash build up and improved efficiency. Boiler has additional domestic hot water coil as optional equipment. Versatile, on-demand hot water available. - Supplying fresh potable hot water for washeterias, laundries, showers, equipment washing, etc. UL listed so there is never a problem with your insurance. Best Warranty in the Industry: Three year on parts Ten year limited warranty on heat exchanger

Black Gold Boiler utilized by the Port of Kodiak for 9 years, since July 1997. Supplying heat and hot water to their Harbor rest & wash room facilities. (Port of Kodiak contact: Lonnie White, Deputy Harbormaster, 486-8080)

M4

Clean ash from the heat exchanger and flue about every 500 hours of operation as indicated by the hour meter. Tools Needed: 1/2 Socket, 5/16 Socket, 3/4 Open End Wrench, Chimney Brush, Small Pipe Brush, Work Gloves, Dust Mask or Respirator, Large Trash Bag, Box

Unplug the burner

Warning: Turn off power at the circuit


breaker before beginning this service. Wear protective clothing, including gloves and a dust mask or respirator. Allow heater to cool. Disconnect 3/8 copper fuel line where it connects to the burner preheater assembly. Unplug the burner. Remove the 2 nuts from the hinged access door and swing the door open. Use a small wire brush to clean all the metal surfaces of the heat exchanger. Lightly brush the ash off of the hinged door and the burner air tube, taking care not to damage the insulation. You may use a shop vacuum to remove the ash also. Remove back access panel by the removing the nuts. The panel will be have ash buildup on it. Position a box underneath it to catch the ash. Lightly tap the flue and allow the ash to fall into the box. Run a chimney brush into the flue to remove ash buildup. Reattach the back access panel. Swing the hinged door closed. Reinstall the nuts and connect the fuel line. Plug the burner in. Allow 15 minutes for

BLACK G OLD

Copper fuel line Clean the boile r tubes

Clean the combustion chamber

Remove the flue access panel to clean flue.


Rev A 02.06.03

Black Gold Model 200 Boiler Installation Cut Sheet - Page 1


Low Water Cutoff 30 psi ASME Relief Valve Aquastat Manual Reset High Limit Aquastat Temperature and Pressure Gauge

Hot Water Supply 1.5" NPT

Aquastat

Cabinet Wiring Box

8" Flue

3/4" NPT Domestic Coil 3/4" NPT

Heat Exchanger Access Door 39.5 Burner Return 1.5" NPT

12

21 50 Left Side

28 Front Burner Side

Domestic Coil

Breach Clean out

1.5" NPT Right Side Back Flue Side

Black Gold Model 200 Boiler Installation Cut Sheet - Page 2


Boiler Description: Horizontal fire tube boiler constructed of welded, hydrostatically tested, 1/4 inch ASME quality steel boiler plate. Horizontal tubes are 2 inch OD by 0.093 wall ASME quality steel tubing. Heating process: The combustion chamber is surrounded by water on all sides but the the burner side. The combustion gas turn back on itself in the cylindrical combustion chamber and enters the 25 horizontal tubes which are surrounded by water. The water absorbs heat from the flue gas. Flue gas then exits the boiler vessel and is exhausted out the flue assembly. Boiler vessell has room at the top for one domestic copper coil heat exchanger for heating of potable process water. Height Including Relief Valve and High Limit Aquastat mounting tee 45 Width Including Controls 32 Depth Including Burner 50 Additional Spacing for Installation: 6 Top and Piping 24 Burner Side (Front) 6 Sides 18 Back Side and Flue Connections Flue size: 8 inch diameter, 8 x 8 x 7 inch flue tee with 7" barometric damper included Boiler Water Capacity: 30 Gallons Low Water Cutoff: ITT McDonnell & Miller 750P-MT-120 Manual reset per UL and ASME Codes Triple Aquastat Relay: Honeywell L8124A or C Honeywell Manual Reset High Limit per UL and ASME Codes Operating Water Pressure: 30 psi Max. Operating Temperature: 230 F Max. Domestic Hot Water Coil Rating: 8.0 GPM Domestic coil connections: 3/4" NPT Complete System UL Tested and Listed Boiler A.S.M.E. Certified Shipping Weight With Burner: 662 lbs. Wet Weight: 1000 lbs. COMBUSTION SPECIFICATIONS Atomizing Air Presssure: 9-11 psi Fuel Flow Rate: 1.40 gph max. Input btuh: 199,000 max. Heating Capacity 5,000 Sq. Ft. with 16 ft. ceilings Input Voltage: 120 VAC 60 Hz Control Voltage: 24 VAC Operating Current: 8.1 Amps UL Approved Fuels: Used Crankcase Oil, Used ATF, #2 Fuel Oil BOILER PIPING CONNECTIONS: 1.5 NPT Supply port at the back of boiler top. 1.5 NPT Return port at center of boiler back Aquastat port: 1/2" NPT Low Water Cutoff port: 3/4" NPT Temperature and Pressure Relief Valve port: 3/4" NPT High Limit Control port: 1/2 NPT

NUERA CORPORATION
E-mail: nueracorp@msn.com PO Box 5357, Kent WA 98064-5357 1-800-347-9575 AK: 907.345.6411

Pricing: Energy Logic/ Black Gold Equipment & Accessories*


FOB Seattle (Effective 5-1-08)

EL140H - MODEL 140 FURNACE (140,000 BTU, 350#)


hEL200H - MODEL 200 FURNACE (200,000 BTU, 380#)

$5,598 $5,998 $7,998

EL340H - MODEL 340 FURNACE (340,000 BTU, 530#)


Furnace included accessories: Three Year Parts Warranty, Integral Air Compressor, High Temp Stainless Steel Chamber/Heat Exchanger, Fuel Metering Pump, Squirrel Cage Ductible Blower, Filtration w/ Spin-on Filter & Vacuum Gauge, Thermostat, Barometric Damper, Draft Gauge, Hour Meter, Pre-wired Electrical Harnesses, & Misc.

EL200B - BOILER 200 (200,000 BTU, 810#)


Add for domestic hot water coil (4 gpm) @ $375

$8,680 $11,980 $15,980

EL375B - BOILER 375 (375,000 BTU, 1030#)


Add for domestic hot water coil (6 gpm) @ $415

EL500B - BOILER 500 (500,000 BTU, 1175#)


Add for domestic hot water coil (8 gpm) @ $475

OPTIONS:
h250 Gallon workbench tank (410#) hPlumbing & hrdw. pkg., tank gauge, furnace stand _Spare parts pkg; nozzle, gasket set, 2 ea. spin-on filters _Oil drain pan to tank, 16x18 w/ screen _Low fuel level cut off float switch _Furnace ash cleanout kit (hvy. duty F/G rod, scraper, chimney brush) _Flue materials (standard through ceiling chimney package with 6" Metalbestos) (8" Metalbestos pkg @ $695) _Complete turn-key INSTALLATION package: materials and labor (variable with travel requirements and building parameters). Customer supplies 120 volt, 20 amp circuit to eq. & permitting if req.

$1,298 $194
$ 89 $ 139 $ 179 $ 89 $ 595 $1,000

hEL200H-CS - Model 200 COMPLETE SYSTEM Furnace Package (Includes Workbench Tank, Stand & Gauge, Plumbing & Hrdw. Pkg.) Customer installed hEL340H-CS - Model 340 COMPLETE FURNACE SYSTEM (with options h above)

$7,490 $9,490

TERMS: Initial 50% deposit; balance upon delivery/installation


Lease/Purchase programs available, seasonal offers @ 0% interest, OAC
*Prices subject to change without notice. Satisfaction Guaranteed.

COMPETITIVE PRICING GUARANTEED We guarantee the best price for your Black Gold System. Contact Steve for details.

by

Adding Profit to Your Business

Vous aimerez peut-être aussi