BEKU 2431 ELECTRICAL ENGINEERING LABORATORY I


Experiment 4: Three-phase Circuits

Group Members

:______________________________________ :______________________________________ :______________________________________

Lab Group Program/Section Date Checked By

:______________________________________ :______________________________________ :______________________________________ :______________________________________

Score

Task Prepared by Confirmed by

Name
Lecturer

Signature

Date

KJ / TD(A)
LAB SHEET Experiment : Three-phase Circuits PAGE: - 1 -

FAKULTI KEJURUTERAAN ELEKTRIK


SUBJECT: ELECTRICAL ENGINEERING LABORATORY I
BEKU 2431

LEARNING OUTCOMES At the end of this laboratory session, students should be able to: perform delta and wye-connection on transformer by considering the specified input and output voltage, ii. perform voltage, current, power factor measurements in three- phase ac circuit, iii. verify the phase and line relationships for the delta and wye-connected loads, iv. calculate the apparent, real, and reactive power in the three-phase system using the measured power factor value i. MATERIAL REQUIRED

Equipment

Power Pack- MV 1300 Load Resistor- MV 1100 Transformer - MV 1915 Clamp Meter/ Multimeter

Quantities Equipment 1 Load Resistor- MV 1100 1 Load Reactor - MV 1101 1 Power Factor Meter- MV 1929 1

Quantities 1 1 1

PART 1: TRANSFORMER (-Y CONNECTION) with WYE-CONNECTED LOADS and CONNECTED LOADS a) WYE- CONNECTED LOADS ASSEMBLY & PROCEDURES Caution: Do not turn ON the power supply for each of the following sections until the circuit is checked by the lab instructor. 1. 2. 3. 4. 5. Connect the circuit shown in Figure 1.1. Set the value of R= 150 for load resistor MV1100. Use the multimeter to set the value of R. Ask the lab instructor to check the connection. Switch ON the power supply and adjust the variable power supply to 230Vac. Use the appropriate measurement meter to determine the line-line voltages, line currents, phase voltages and phase currents for all the phases in the load side. 6. Record all the measured values obtained. 7. Adjust the variable power supply to zero volts. 8. Turn OFF the circuit breaker (to switch OFF the power supply).

230V / 133V Figure 1.1: Loads in Wye-Connection

LAB SHEET

Experiment : Three-phase Circuits

PAGE: - 2 -

FAKULTI KEJURUTERAAN ELEKTRIK


SUBJECT: ELECTRICAL ENGINEERING LABORATORY I
BEKU 2431

b) - CONNECTED LOADS 1. Repeat all the procedure given above (i.e. steps 1 to 8), but in this case the WYE-connected load is changed to the -connected load as depicted in Figure 1.2.

230V / 133V

Figure 1.2: Loads in -Connection


PART 2: POWER FACTOR MEASUREMENT FOR WYE- CONNECTED LOADS AND CONNECTED LOADS

a) WYE- CONNECTED LOADS ASSEMBLY & PROCEDURES Caution: Do not turn ON the power supply for each of the following sections until the circuit is checked by the lab instructor. 1. Connect the circuit shown in Figure 1.3. 2. Set the value of R = 150 for load resistor MV1100 unit (use the multimeter to determine the desired resistance value). 3. Set the value for load reactor to position 3. 4. Ask the lab instructor to check the connection. 5. Switch ON the power supply and adjust the variable power supply to 230Vac. 6. Record the power factor value obtained from the power factor meter. 7. Use the appropriate measurement meter to determine the line-line voltages, line currents, phase voltages and phase currents for all the phases in the load side. 8. Record all the measured values obtained. 9. Adjust the variable power supply to zero volts. 10. Turn OFF the circuit breaker.

230V / 133V Figure 1.3: Power Factor measurement for Wye- connected loads
LAB SHEET Experiment : Three-phase Circuits PAGE: - 3 -

FAKULTI KEJURUTERAAN ELEKTRIK


SUBJECT: ELECTRICAL ENGINEERING LABORATORY I
BEKU 2431

b) - CONNECTED LOADS 1. Repeat the procedure given in PART2(a), but this time the WYE-connected load is changed to the -connected load as shown in Figure 1.4.

230V / 133V Figure 1.4: Power Factor measurement for - connected loads

LAB SHEET

Experiment : Three-phase Circuits

PAGE: - 4 -