Detailed/Tentative Estimate on Account of Supply, Installation, Testing and Commissioning of Horizontal Type Pumping Units at Dewatering Station Doulatabad

IPS # 6 S.NO 10-Cusec Pumping Unit 1. PARTICULARS QTY RATE AMT

Supply, Installation, Testing & Commissioning of 10-Cusec pump sets with 70 HP Motor .The equipment supplied shall conform to latest IS-standards and codes with fail safe circuits /devices Pumping units complete in all respects with following specifications. [A] PUMP (10-cusec ) a) Capacity : 10-cusec b) Type : Horizontal, centrifugal type, non clogging c) Preferable size : 35x35 cm d) Solid handling capacity: > 80mm e) Head : 10mtrs f) Speed : 970rpm g) Efficiency : 70 % h) Impeller : C.I/Bronze i) Pump casing : C.I j)Pump shaft : AISI-410 k) NPSHA : 2.80 m [B] MOTOR a) Rated capacity : 70 hp b) No. of phase : 3 phase c) Frequency : 503% d) Insulation : F-class e) Insulation protection : IP-68 f) Input voltage : 41510% g) Starting : Star/Delta h) Al.Cable(3 core,20 mtrs): 95mm i) Enclosure : SPDP

j)Speed
k)Type Make Base frame

: 1000rpm
: Squirrel cage ,horizontal foot mounted A.C. induction Motor. :Grundfos, Beacon, Kirloskar, Flow more :M.S. channel fabricated base frame of rigid construction along with a set offoundation pads of suitable size :Flexible rubber coupling with C.I flanges, complete with tyre element, nuts bolts Suitable for above pumping units.

2 jobs

Coupling

7.75 lacs/job

15.50lacs

S.N O. 2.

PARTICULARS
5-Cusec Pumping Unit Supply, Installation, Testing & Commissioning of 5-Cusec pump sets with 40 HP Motor .The equipment supplied shall conform to latest IS-standards and codes with fail safe circuits /devices Pumping units complete in all respects with following specifications. [A] PUMP (5-cusec ) a) Capacity : 5-cusec b) Type : Horizontal, centrifugal type, non clogging c) Preferable size : 25x25 cm d) Solid handling capacity: >60mm e) Head : 10 mtrs f) Speed : 1450rpm g) Efficiency : 70 % h) Impeller : C.I/Bronze i) Pump casing : C.I j)Pump shaft : AISI-410 k) NPSHA : 2.70 m [B] MOTOR a) Rated capacity : 40 hp b) No. of phase : 3 phase c) Frequency : 503% d) Insulation : F-class e) Insulation protection : IP-68 f) Input voltage : 41510% g) Starting : Star/Delta h) Al.Cable(3 core,20 mtrs): 35mm i) Enclosure : SPDP

QTY

RATE

AMOUN T

j)Speed
k)Type Make Base frame

: 1500 rpm
: Squirrel cage ,horizontal foot mounted A.C. induction Motor. :Grundfos, Beacon, Kirloskar, Flow more :M.S. channel fabricated base frame of rigid construction along with a set offoundation pads of suitable size :Flexible rubber coupling with C.I flanges, complete with tyre element, nuts bolts Suitable for above pumping units.

Coupling

2 jobs

3.75 lacs/job

7.50 lacs

Total Amount =23.00 lacs

Report:

The above detailed tentative estimate amounting to Rs.23.00 Lacs (Rs. Twenty Three lacs only) has been framed to cover the cost on account of Supply, Installation, and Testing & Commissioning of 10-Cusec & 5- Cusec horizontal type pump sets for Dewatering station Daulatabad IPS#6.Submitted for further necessary action at your end please.

Jr. Engineer

Jr. Engineer

Asstt. Engineer

Asstt. Ex. Engineer (Mech.)

Detailed/Tentative Estimate on Account of Providing, Fitting, Testing and Commissioning Of Various Electrical works at Dewatering Station Doulatabad IPS # 6 S.N O. 1. PARTICULARS
Distribution/Control Panel Providing, Fitting and Commissioning of electrical distribution/Control panels comprising of 01 No. incoming feeder 02 No. outgoing feeders and 01 No. auxiliary feeder. a).The incoming feeder shall consist of :i). 400 Amp,4 pole,35KA MCCB. ii) 400 Amp TPN Aluminum Bus Bar. iii). 400Amp, 4 pole 415 volt Change over switch. iv) (0-500V) Digital voltmeter with selector switch. v). (0-500 A) Digital Ampere meter CT operated of suitable ratio and with selector switch. vi). Digital Frequency meter . vii). RYB phase indicator lamps. b). Outgoing feeder No. 01 shall consists of :i). 250 Amp, TP Aluminum Bus Bar. ii. 250A, 3 poles MCCB, 35KA. iii. FASD ML-6 Starter conforming to latest IS standards &Codes, shall be fitted with preventive devices and Capacitor banks, with manufacturers test certificate. iv).(0-500V) Digital voltmeter with selector switch. v). (0-500 A) Digital Ampere meter CT operated .of suitable ratio with selector switch. vi). RYB Phase indicators c) Out going feeder no. 02 & 03 shall consists of :i)200 Amp TP Aluminum Bus Bars ii)200 Amp,3 pole MCCB, 25 KA iii) FASD ML-6 Starter conforming to latest IS standards &Codes with manufacturers test certificate. shall be fitted with preventive devices and Capacitor banks. iv).(0-500V) Digital voltmeter with selector switch v). (0-500 A) Digital Ampere meter CT operated of suitable ratio with selector switch vi). RYB Phase indicators d) Auxiliary feeder shall comprising of :i.) 63 Amp MCB. ii) D.O.L. 7.5 HP starter The electrical control panel shall be made out of 14gauge CRCA housing, every section of the panel shall have separate shutters, fabricated in such a way that when opened the equipment fitted shall easily be accessible . Make of switch gear, circuit breaker = L&T, Havells, Siemens. AE &EE ( accompanied with manufacturers test certificate)

QTY

RATE

AMOUN T

4.75

9.50

Job also includes proper earthing to all the electrical equipments & main control panel. The earthing to be carried out through galvanized Aluminum strip of appropriate rating

jobs

lacs/j ob

lacs

S.N O. 2.

PARTICULARS
Servo Controlled Voltage stabilizer Providing, fitting, testing and commissioning of Servo Controlled Voltage stabilizer of 200 KVA having following specifications :i. Capacity =200 KVA ii. Input Voltage Rang Extended = 240 V to 465 V iii. Output Voltage = 380 V / 400 V / 415 V iv. Regulation = - 1% , Efficiency 96% v. Input Frequency = 50 Hz 3Hz vi. Motor drive Heavy duty AC Synchronous Motor vii. Indication Mains On Output, On Low Cut-off ,High Cut-off vii. Metering= Analog Voltmeter to read Input & Output Voltage to each phase viii. Operating Temperature. 45 C ix. Duty cycle Continuous x. Nature of Cooling - Oil Cooled. xi. Protection= Over Voltage, Under Voltage, Over Load, Short Circuit. xii. Stabilizer Standard As per IS 9815 Oil Standard As per IS 335. (The equipment shall be supported with manufacturers test certificates). Illumination of pump house premises : Illumination of pump house premises with 250 Watt sodium vapour lamp assemblies to be erected on 7 mts long M.S pole 5mm thick with varying diameters of 125mm, 80mm, 75mm. with single arm complete in all respects which includes 250 Watts sodium vapor lamps ,CA power pack /blast of 250 watts capacity, cabling, earthing etc. Electrification of pump station: Electrical circuits are to be carried out in 3/20 & 7/20 pvc insulated copper cable for lighting and heating points respectively .The cable is to be laid through pvc channels ,bends ,Ts fitted on the walls by gutties etc. The circuit should be complete in all respects fitted with 6/16Amp. MCBs , MCB boxes etc i. Lighting point Jeta 6 RO 250W SON-T/MH lamp assembly with on/off switch. (03No.) ii. Lighting point 100 watts Lamps through angle holder assembly with on/off switch (06 No). iii. Heating point in 7/20 pvc insulated copper cable along with 15 amp, switch socket combine (06 No) iv. 300mm dia swap exhaust fan ( 02No.)

QTY

RATE

AMOUN T

2job s

3.25 lacs/j ob

6.5 lcas

3.

3 jobs

0.30 lacs/j ob

0.90 lacs

4.

v. 1200mm dia swap fresh air fan (01 No). vi. Shock proof chequered rubber 1x2mx15mm = 8 sq mts.

matting

11kv

grade

Make= Bajaj, Havels, Anchor, Legrand, Khaitan, Usha, HPL.

1job

0.70 lacs/j ob

0.70 lacs

S.N O. 5.

PARTICULARS
Electric Cabling Providing, Fitting, Testing, Installation and Commissioning of 300 mm sq. 3.5 core aluminum armoured cable XLPE Sheathed PVC insulted conforming to the latest IS Codes 1554 ,from HTLT SubStation up to main distribution Control Panels. Make ; Havells/CG/HPL (The item shall be supported with manufacturers test certificates).

QTY

RATE

AMOU NT

70 mts

0.02 lacs/ mtr

1.40 lacs

Tot al Amount= Rs19.00 lacs

Report:
The above detailed tentative estimate amounting to Rs.19.00Lacs (Rs. Nineteen Lacs only) has been framed to cover the cost on account of Providing, fitting , and Testing & Commissioning of Various electrical works at Dewatering station Daulatabad IPS#6 Submitted for further necessary action at your end please.

Jr. Engineer

Jr. Engineer

Asstt. Engineer

Asstt. Ex. Engineer (Mech.)

Detailed/Tentative Estimate on Account of Providing, Fabrication, Installation, Testing and Commissioning of Suction and delivery Conduits with allied Mechanical works at Dewatering Station Doulatabad IPS # 6

S.N O. 1.

PARTICULARS
Delivery Manifold Providing, fabrication, Installation, Testing and Commissioning of delivery manifold with allied items as per below details: i) M.S flanged Manifold 6 mtrs long for pumps of enlarging diameter from 350mm to 450mm fitted with 2 No. 250mm bends &01 No.350mm bend of thickness 8mm. ii) 450mm common Delivery pipe line, 8mm barrel thickness Length of 10.mts from delivery manifold upto already laid Delivery line through 01 No. 450mm S-type flanged bend, 01No. 450mm 90 long radius flanged Bend & 1 No. flanged increaser (450 500mm).The common delivery is to be laid underground / aboveground on saddle blocks to be provided by the concerned civil subdivision. Suction/Delivery Conduit for 2 No. 10- cusec Pumping units Providing, fabrication, Installation, Testing and Commissioning of suction/delivery Conduit for 2 No. 10- cusec Pumping units with allied mechanical jobs as per below details: i) 350mm suction / delivery pipe line to be of 6mm barrel thickness of approximate 14mtrs length from foot valve upto common delivery manifold including 09 No. flanged bends. ii) Sewage control valves, NRVs, Foot valves 350mm of P.N.-1.0 rating and of make : Kirloskar /Leader/C&F/Konark. supported with manufacturers test certificates. Suction/Delivery Conduit for 2 No. 5- cusec Pumping units Providing, fabrication, Installation, Testing and Commissioning of suction/delivery Conduit for 2 No. 5- cusec Pumping units with allied mechanical jobs as per below details: i) 250mm suction /delivery pipe line to be of 6mm barrel thickness of approximate 15 mtrs length from foot valve upto common delivery manifold including 08 No. flanged bends. iii) Sewage control valve, NRV, Foot valve 250mm of P.N.-1.0 rating and of make : Kirloskar/ Leader/C & F /Konark supported with manufacturers test certificates. Providing and fitting of Pressure gauge as per the requirement of pumps. Make = H-Guru/Weree/Hiebig.

QTY

RATE

AMOUN T

2.

1 job

4.40 lacs/j ob

4.40 lacs

1 job

3.

11.20 lacs/j ob

11.20 lacs

1 job 4 jobs

4. 5.

5.64 lacs/j ob 0.04 lacs/j

5.64 lacs

0.16

Fabrication ,Providing ,Hoisting and fixing in position of Monorail Travelling gantry inside the pump house (3.5mt x 10.5mt) .The rail girders to be of size ISMB-150 fitted with 25mm sq.bar on top and supported on 12 No. wall brackets(250x200 mm) fabricated out of 10 mm M.S plate .The Traveling girder of ISMB-250, 3.5m long fitted with end carriage assemblies on both ends and Provided with 2-Tonne capacity Monorail and chain pulley block (Make; Indef, Pull lift ) complete in all respects.

ob

lacs

1 job

2.60 lacs/j ob

2.60 lacs

S.N O. 6.

PARTICULARS
Gantry over sump : Fabrication, Providing, Fitting of MS Gantry Over sump 02 Nos. Columns of Gantry are to be fabricated out of ISMC-150, 4 mts long placed face to face 75 mm apart held together through 6mm thick MS plates 225 X 150 mm at 04 places on both sides.3000X300mm MS plates 12mm thick are to be fitted on top and bottom side of column .Bottom plate is to be welded to the reinceforcement of the sump and grouted in PCC block . ISMB-200 ,6mts long is to be placed and welded to the top plate of the columns .The job also includes Providing and Fitting of one no. 2-tonne capacity chain pully block with monorail (Indeff make ) Details of steel : MS plate 12mm =0.36sq mt 06mm =0.54sqmt ISMC-150 =16RMT ISMB-200 = 06RMT Priming unit : Providing, Installation, Testing & Commissioning of 02Nos self priming pump unit coupled to A.C induction Motor through suitable flexible coupling arrangement mounted on a common base frame.The pump motor assy. to be installed on a foundation block PCC1:2:4 concrete mix to be laid by the agency. The job includes Providing and fixing in position T/J foundation bolts.Specifications are as under : a) Pump : 02 No. (01 Working+ 01 standby) i) Size =50 x 50mm ii) Capacity =5-9 LPS iii) Head =6-12 mt iv) Acceptable make = Kirloskar or equivalent v) Speed =1450 RPM b) Motor :02 No. (01 Working+ 01 standby) i) H.P =5 ii)Phase =03 iii) Volt =41510% iv) Acceptable make = Crompton/ Greaves or relevant make v) Speed =1450 RPM vi) Frequency = 50 Hz 2 % c) Providing & Fitting of 50mm dia G.I pipe as suction & delivery

QTY

RATE

AMOUN T

1 job

7.

0.75 lacs/j ob

0.75 lacs

pipes for the 4-units .The job includes cutting /threading of pipe in to required length as per site requirement .The pipe fitting is to be carried through 50mm dia. Flanges along with gaskets and screw fasteners including 07 No.,50mm dia G.I flanged bends ,Tees etc. along with 04 No.,50mm dia G.M heavy duty gate valve & 01 No. C.I foot valve (50mm) are to be fitted in the priming system.

S.N O.

PARTICULARS
d) Providing & fitting of electric system for priming pumping unit comprising of 7/0.020 PVC insulated copper conductor (45 mts appox.) to be fitted and laid from motor upto D.O.L starter fitted in auxiliary panel. The copper conductor to be laid in pvc conduit with clamps and gutties along the pump house wall. e) Air vent system Providing &Fitting of air vent system (i) 5- Cusec Pumping Unit 02 N0. It shall comprise of 19mm dia , 100mm long nipples 02 No. 19mmdia elbow,02 No.19mm dia gate valve G.M heavy duty 2 No. 25mm dia foam pipe fitted with clamps(10mts) complete in all respects for two units. (ii) 10- Cusec Pumping unit 02 No. It shall comprise of 25mm dia , 100mm long nipples 02 No. 25mmdia elbow,02 No.25mm dia gate valve G.M heavy duty 2 No. 35mm dia foam pipe fitted with clamps(10mts) complete in all respects for two units.

QTY

RATE

AMOUN T

1 job

1.25 lacs/ job

1.25 lacs

Total Amount= Rs 26.00 lacs only

Report:
The above detailed tentative estimate amounting to Rs.26.00Lacs (Rs. Twenty six Lacs only) has been framed to cover the cost on account of Providing, Fabrication, Installation, Testing and Commissioning of Suction and delivery Conduits with allied Mechanical works at Dewatering Station Doulatabad IPS # 6

Submitted for further necessary action at your end please.

Jr. Engineer

Jr. Engineer

Asstt. Engineer

Asstt. Ex. Engineer (Mech.)