Product data sheet

Characteristics

LC1F2100

CONTACTEUR 2100A 3P NU

Main
Range of product Product or component type Device short name Contactor application Utilisation category Control circuit type Coil type Poles description Pole contact composition [Ie] rated operational current [Uc] control circuit voltage Connections - terminals TeSys F Contactor LC1F Resistive load AC-1 AC DC Standard 3P 3 NO 2100 A (<= 40 C) AC AC-1 for power circuit 780 A (<= 55 C) AC AC-3 for power circuit 230 V AC 40...400 Hz Power circuit: bars 4 Control circuit: connector 1 cable 1...4 mm - cable stiffness: flexible - with cable end Control circuit: connector 2 cable 1...4 mm - cable stiffness: solid - without cable end Control circuit: connector 2 cable 1...4 mm - cable stiffness: flexible - without cable end Control circuit: connector 2 cable 1...2.5 mm - cable stiffness: flexible - with cable end Control circuit: connector 1 cable 1...4 mm - cable stiffness: solid - without cable end
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Complementary
Coil technology Auxiliary contacts type Auxiliary contact composition Control circuit voltage limits [Ui] rated insulation voltage [Uimp] rated impulse withstand voltage Mounting support Tightening torque Built-in bidirectional peak limiting diode suppressor Without built-in bidirectional peak limiting diode suppressor Type integrated in coil (1 NO) 1 NO 0.2...0.35 Uc at <= 55 C drop-out 40...400 Hz 0.85...1.1 Uc at <= 55 C operational 40...400 Hz 1500 V for power circuit conforming to VDE 0110 group C 1000 V for power circuit conforming to IEC 60947-1 8 kV coil not connected to the power circuit Plate Rail Control circuit: 1.2 N.m - on connector - cable 1...4 mm Control circuit: 1.2 N.m - on connector - cable 1...2.5 mm Power circuit: 58 N.m - on bars <= 1000 V AC 16 Hz 2/3...200 Hz for power circuit 2100 A at <= 40 C for power circuit 3150 A at <= 1000 V AC for power circuit conforming to IEC 60497-4-1 3150 A at <= 1000 V for power circuit conforming to IEC 60497-4-1 1000 A gG at <= 440 V for power circuit 0.1 mOhm at 50 Hz - Ith 2100 A for power circuit 200 W AC-1 2200 VA at 20 C (cos 0.9) 2100 W at 20 C 36 VA at 20 C (cos 0.9) 40...400 Hz 10 W at 20 C 1

[Ue] rated operational voltage [Ith] conventional free air thermal current Irms rated making capacity Rated breaking capacity Associated fuse rating Average impedance Power dissipation per pole Inrush power in VA Inrush power in W Hold-in power consumption in VA Hold-in power consumption in W
May 5, 2012

Operating time Mechanical durability Operating rate Height Width Depth Product weight

40...75 ms on closing 100...170 ms on opening 5000000 cycles 600 cyc/h at <= 55 C 332 mm 438 mm 238.6 mm 31 kg

Environment
Standards EN 60947-1 EN 60947-4-1 IEC 60947-1 IEC 60947-4-1 JEM 1038 CCC CSA UL IP20 front face with cover conforming to VDE 0106 IP20 front face with cover conforming to IEC 60529 TH -60...80 C -5...55 C -40...70 C at Uc 3000 m without derating in temperature 850 C conforming to IEC 60695-2-1 6 gn contactor opened 15 gn contactor closed 4 gn 5...300 Hz contactor closed 2 gn 5...300 Hz contactor opened 36 W at 40...400 Hz for control circuit

Product certifications

IP degree of protection Protective treatment Ambient air temperature for operation Ambient air temperature for storage Permissible ambient air temperature around the device Operating altitude Fire resistance Shock resistance Vibration resistance Heat dissipation

Offer Sustainability
Sustainable offer status RoHS Product environmental profile Not Green Premium product Compliant - since 0927 - Schneider Electric declaration of conformity declaration of conformity Available Download Product Environmental download