Application Note Technote: Clearing password protected Micrologix & SLC500 processors

Application Note

Page 1 of 3

A16851 - Clearing password protected Micrologix & SLC500 processors

Last Modified: 04/21/2005 Previously Released as #10734

General Category:s Programmable Controllers Product(s): SLC500 (1747); MicroLogix 1000 (1761); MicroLogix 1200 (1762); MicroLogix 1500 (1764); MicroLogix 1500 (1764) Catalog #: 1747L20A; 1747L20B; 1747L20C; 1747L20D; 1747L20E; 1747L20F; 1747L20G; 1747L20L; 1747L20N; 1747L20P; 1747L20R; 1747L30A; 1747L30B; 1747L30C; 1747L30D; 1747L30L; 1747L30P; 1747L40A; 1747L40B; 1747L40C; 1747L40E; 1747L40F; 1747L40L; 1747L40P; 1747L511; 1747L514; 1747L524; 1747L531; 1747L532; 1747L541; 1747L542; 1747L542P; 1747L543; 1747L551E; 1747L552E; 1747L553E; 1761L16AWA; 1761L16BBB; 1761L16BWA; 1761L16BWB; 1761L20AWA-5A; 1761L20BWA-5A; 1761L20BWB-5A; 1761L32AAA; 1761L32AWA; 1761L32BBB; 1761L32BWA; 1761L32BWB; 1762L24AWA; 1762L24BWA; 1762L40AWA; 1762L40BWA; 1764LDP; 1764LRP; 1764LSP Series / Revision: Subject configuration, instructions (Keyphrases): Summary of Technote Information:

The following procedure can be used to restore defaults to a Micrologix or SLC-500 processor when the software requests a password. Supported Software: RSLOGIX 500 v3.01.09.02 or greater. RSLOGIX 500 v6.00.00 does NOT support his procedure. RSLOGIX 500 v6.10.00 or greater. APS and AI 500 software do not support this procedure.

NOTE: By following this procedure the program in the Processor will be erased.
1) When prompted for the password enter MLCLRMEM , using the keypad of a telephone you must translate this into its numeric equivalent of " 65257636 "

http://domino.automation.rockwell.com/applications/kb/RAKB.nsf/0/E7F7A812D86B6779852...

9/16/2006

Application Note Technote: Clearing password protected Micrologix & SLC500 processors

Page 2 of 3

2) You will be prompted to confirm the clearing of the processor ladder logic program.

http://domino.automation.rockwell.com/applications/kb/RAKB.nsf/0/E7F7A812D86B6779852...

9/16/2006

Application Note Technote: Clearing password protected Micrologix & SLC500 processors

Page 3 of 3

3) Once this is confirmed the processor will return to a default ( Out of the Box ) state with it's default program. The software will then return offline to it's default screen.
Related Links:

DISCLAIMER This knowledge base web site is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this web site is not intended to constitute application, design, software or other professional engineering advice or services. Before making any decision or taking any action, which might affect your equipment, you should consult a qualified professional advisor. ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS." IN NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES. ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT OF THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you.