Vous êtes sur la page 1sur 2

CONSTANT PRESSURE FILTRATION.

XLS
Constant pressure filtration readings from vacuum or pressure test
cake and cloth resistance follows from
equation (2.23)

Filtrate time over volume,


s/m^3.

INPUTS
********* ********* *********
Filter area:
Liquid viscosity:
Liquid density:
Solids in slurry weight fraction:
Mass of wet cake sample:
Mass of dry cake sample:
*********
Filtration Filtration Filtrate
*********
time
pressure
Volume
*********
*********
(s)
(bar)
(m^3)
*********
0
3
0 *******
92
3
0.024 *********
160
3
0.039 *********
232
3
0.054 *********
327
3
0.071 *********
418
3
0.088 *********
472
3
0.096 *********
538
3
0.106 *********
Average:
3 bar

********* *********
2.72
0.001
1000
0.1
1280
635
********* *********
Time
Pressure
over
forming
volume
cake
(s/m^3)
(Pa)
3833.3333
4102.5641
4296.2963
4605.6338
4750
4916.6667
5075.4717

50295
73977
93557
112013
127440
133856
141235

m^2
Pa s
kg/m^3
g
g
*********
Fitted
t/V
(s/m^3)
3859.785231
4080.501486
4301.217742
4551.362832
4801.507922
4919.223258
5066.367429

0.12
Filtrate volume, m^3.

6000
5000
4000
3000
2000
1000
0
0

0.05

0.1

Filtrate volume, m^3.

0.15

0.1
0.08
0.06
0.04
0.02
0
0

200
Time, s.

CALCULATED VALUES:
********* ********* *********
Moisture ratio of cake:
2.015748
Dry cake per filtrate volume (equn 2.18):
125.24655 kg/m^3
Filtration pressure:
300000 Pa
Cake specific resistance:
5.215E+11 m/kg
Cloth resistance:
2.861E+12 m^-1
Cake forming pressure:
134176.96 Pa
********* ********* ********* ********* ********* *********
Regression Output:
Constant
3506.6392
X Coefficient(s)
14714.417
R Squared
0.9943521