Low HV Shutdown: On the D Board. Check IC8004/pin 7 should be 7.4v. Check IC8006/pin 2 should be 2.

5v if lower will trigger shutdown by causing pin 1 to turn on. Check IC8006/pin 3 reference voltage 2.2v. IC8006/pin 1 normally at 0v. If high turns D5007 ON which turns the latch circuit Q6532, Q6530, and Q6527 ON and turns the AC relay RY6501 OFF. NOTE: 6 blinks also can be Low B+ protection. Unregulated 7.5 v from the power supply to 5v reg IC504 on the A Board. 5v to M Board Q2314 to CPU IC2300/pin 43. If 5v missing set will shutdown with 6 blinks.

Here are the blinking codes I found online here. I've also found that you can order a complete G Board (power supply) part no. A1316399A for the KV-35S42 at www.tritronicsinc.com for $116.25. Something to think about if you KNOW the problem is on that board. Unit is dead, No blinks - Problem in the standby power section. Might check fuse, R607, Q601, IC601, R612 and VDR601 (should show open). Continuous blink once a second, no pausing - No reply from the jungle IC301 (data bus is busy, shorted to ground, or held high), IK video path is defective. I have found no such part in the Service Manual for KV-35S42. One blink - not used for the self-diagnosis Two blinks - B+ over current protection (OCP), the unit goes into standby mode then displays the 2 blink fault. This could be a short in the power supply of any of the circuits. Three blinks - B+ over voltage protection (OVP), the unit goes into standby mode then displays the 3 blink fault. This is also a problem in the power supply circuit, check T603 and R672. Four blinks - No vertical Deflection (V STOP), Screen goes to a single horizontal line then the video signal muted. Check IC1509, Q1505 Five blinks - AKB circuit (automatic kine bias), the timer/standby indicator blinks for about 30 seconds

then goes to the self-diagnosis function. Something is wrong with the video. Check video out, Q705, 732, 761 and other components on the C board, also check Q218, 219, 220 on the A board. In addition, unit could be in IK blanking, try turning up screen slightly. Six blinks - No Horizontal (H STOP), no raster, goes to the blinking self-diagnosis function immediately. Check C515 & 516 and the jungle IC, IC206. Seven blinks - High voltage shutdown. The high voltage has exceeded 33k and the unit goes immediately into safety shutdown. Check power supply regulation and horizontal circuits. Eight blinks - Problem with the audio (AUDIO), unit goes to standby and blinks the self-diagnosis code. Check IC406 audio amp, PS401, and 402. On some projection models of Sony TV sets, this code means that T8005 (fly back transformer), or the associative components in the high voltage circuits are defective on the D board. Nine blinks - Replace D 6116 and D 6301 on the "G" board, do not resolder as this will fix the problem temporary. This could also be a Panel Module Error or Thermal Error. If it is intermittent 9 blinks, meaning sometimes the TV comes on and other times you get flashing, then change the switching regulator on the "G" board or check connections. Make sure the regulator is -12 or -13 (negative). Ten blinks - Check Q8014 and Q8013 for shorts, leakage, or bad solder connections on the "D" board. If the transistors are bad, check R8051 and IC8005, also on the "D" board.

Vous aimerez peut-être aussi