Vous êtes sur la page 1sur 6

SilkWorm Fabric AP7420 Power Supply

Replacement Procedure

Supporting XPath OS v7.1.0 Supporting SilkWorm Fabric AP7420

Publication Number: 53-0001651-04

*53-0001651-04*
Publication Date: 03/22/2004

Copyright 2004, Brocade Communications Systems, Incorporated. ALL RIGHTS RESERVED. Publication Number: 53-0001651-04

Brocade, the Brocade B weave logo, Secure Fabric OS, and SilkWorm are registered trademarks of Brocade Communications Systems, Inc., or its subsidiaries in the United States and/or in other countries. FICON is a registered trademark of IBM Corporation in the United States and other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners. Notice: The information in this document is provided AS IS, without warranty of any kind, including, without limitation, any implied warranty of merchantability, noninfringement or fitness for a particular purpose. Disclosure of information in this material in no way grants a recipient any rights under Brocade's patents, copyrights, trade secrets or other intellectual property rights. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. The authors and Brocade Communications Systems, Inc., shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it. Notice: The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/ support/oscd. Export of technical data contained in this document may require an export license from the United States government.

Brocade Communications Systems, Incorporated


Corporate Headquarters 1745 Technology Drive San Jose, CA 95110 T: (408) 333-8000 F: (408) 333-8101 Email: info@brocade.com European Headquarters 29, route de lAeroport Case Postale 105 CH-1211 Geneva 15, Switzerland T: +41 22 799 56 40 F: +41 22 799 56 41 Email: europe-info@brocade.com Latin America Headquarters 5201 Blue Lagoon Drive Miami, FL 33126 T: (305) 716-4165 Email: latinam-sales@brocade.com

Asia-Pacific Headquarters Shiroyama JT Trust Tower 36th Floor 4-3-1 Toranomon, Minato-ku Tokyo, Japan 105-6036 T: +81 35402 5300 F: +81 35402 5399 Email: apac-info@brocade.com

Document History
The table below lists all published versions of the Brocade SilkWorm Fabric AP7420 Power Supply Replacement Procedure. Document Title SilkWorm Fabric AP7420 Power Supply Replacement Procedure SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number
53-0001651-03 Early Access Draft

Summary of Changes Publication Date First release. None. March 2004 March 2004

53-0001651-04

2 of 6

SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number: 53-0001651-04

Use this procedure to remove and replace a power supply in the Brocade SilkWorm Fabric AP7420. The power supplies (one or two) are hot-swappable if one power supply remains operating during the procedure. Each power supply is identical and fits into either power supply slot. The Brocade XPath OS identifies a power supply according to the slot it occupies (see Figure 1). For example, if only one power supply is installed in the SilkWorm Fabric AP7420, and it is installed in power supply slot #2, it is identified as power supply #2. Figure 1 Power Supply Removal and Replacement

Silkworm AP7420

A
PO WER

PO RT S SY ST EM

D
DC OK AC OK

0 1 2 3 4 5 6 7
10 0-24

8
0 VA C 6.0

9
A 47 -63 Hz

10

11

12

13

E F

14

15

MG

MT2 MG MT1

SP EE FC D /G LIN bE K/ AC

LIN T

CO NSO LE

SP ACTIV EE D IT Y

BR

Silk Wo rm

CA

AP 74

DE
20

A
DC OK AC OK

scale: 1/8" = 1"

10

0-24

0 VA C 6.0

A 47

-63

Hz

B C
001

Item A B C

Description Power supplies (2) Handle (yellow) Captive screw

Item D E F

Description Location of power supply LEDs AC receptacle and switch Power supply slot #2

SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number: 53-0001651-04

3 of 6

Time Required
Less than 15 minutes.

Items Required

New power supply Phillips screwdriver Caution Disassembling any part of the power supply voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the power supply. Since the cooling system relies on pressurized air, do not leave either of the power supply slots empty longer than 15 minutes while the SilkWorm Fabric AP7420 is operating. If a power supply fails, leave it in the SilkWorm Fabric AP7420 until it can be replaced. Maintain both power supplies in operational condition to provide redundancy. Each power supply has two LEDs that indicate its status, as follows: LED DC OK On (green) Off Off AC OK On (green) On (green) Off Normal operation DC output failure AC failure or no input power Status

Caution Do not remove a power supply until the other one is verified as powered on for at least four seconds and both of its LEDs are green (on). If you intend to replace a power supply while the SilkWorm Fabric AP7420 is operating, the replacement power supply must be installed and operating within 15 minutes to maintain correct air pressure within the chassis.

4 of 6

SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number: 53-0001651-04

Procedure
Follow these steps to remove and replace a power supply: 1. 2. 3. If the SilkWorm Fabric AP7420 is to continue operating during the replacement, verify that the other power supply has been powered on for at least four seconds and both of its LEDs are green (on). Power off the power supply being replaced by pressing the AC power switch to 0; then unplug the power cord from the AC receptacle. See Figure 1 for the location of the AC power switch and receptacle. Remove the power supply from the chassis: a. b. c. 4. Unscrew the captive screw (see Figure 1). If the captive screw is too tight, use a Phillips screwdriver to loosen the screw. Grasp the yellow handle on the power supply (see Figure 1). Pull the power supply straight out of the chassis.

Install the new power supply: a. b. c. Verify that the AC power switch is in the 0 position. Orient the power supply as shown in Figure 1, with the yellow handle on the right. Gently push the power supply into the chassis until it is firmly seated. Caution Do not force the installation. If the power supply does not slide in easily, ensure that it is correctly oriented before continuing with the installation. d. Tighten the captive screw.

5. 6.

Connect the power cord to the power supply and press the AC power switch to 1. Verify that both LEDs on the new power supply display a continuous green light while the SilkWorm Fabric AP7420 is operating. If either of the LEDs is not green, ensure that the power supply is firmly seated.

Enter psshow at the command line prompt to view power supply status. For more information about this command, refer to the XPath OS Command Reference Manual.

SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number: 53-0001651-04

5 of 6

6 of 6

SilkWorm Fabric AP7420 Power Supply Replacement Procedure Publication Number: 53-0001651-04