FibeAir IP-10 G-Series

Installation

Proprietary and Confidential

General
If installation requires CFG file upload & download and / or SW file upload & down -

1. 2. 3.

Make sure FTP Server is installed on your PC FTP is configured (RD/WR permissions) Latest SW version is available (FTP root directory)

FTP installation guide is available at Training.Ceragon.Com: see Modules / Installation

Proprietary and Confidential

Site Requirements
IDU must be located indoors

The environment temperature must be between -5 C and +45 C.


Easily accessible, but only by authorized personnel. Available power source of -48 VDC, and the site must comply with National Electric Code (NEC) standards. Available management connection (Ethernet or dial-up). IDU-ODU connection (IF cable): no more than 300m

Proprietary and Confidential

Site Requirements
Heat Dissipation:
The IP-10 IDU overall heat dissipation is 25W max (~85 BTU/h). The ODU heat dissipation is 100W max.

Antenna Location:
As with any type of construction, a local permit may be required before installing an antenna. It is the owners responsibility to obtain any and all permits.

Proprietary and Confidential

IDU Dimensions

42.60mm

Proprietary and Confidential

Installing standalone IDU in a 19 Rack

As shown in the illustration, four screws, supplied with the installation kit, are used to secure the IDU to the rack.

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Before you install the enclosures Plan carefully the required space within the rack ! Should you need to install 3 enclosures prepare at least 10Us (6Us for enclosures + 2Us free Main Enclosure
space for maneuvering above and below shelves)

Start the installation process from bottom to top, e.g. Main enclosure should be installed first at the bottom of your rack space
8
Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Step #1: Install the IP-10 Main enclosure in the 19 inch rack using 4 screws.

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Step #1: Install the IP-10 Main enclosure in the 19 inch rack using 4 screws. Step #2: Slide down the 2nd extension enclosure. Male connector should plug in smoothly into the Main enclosure.

10

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Step #1: Install the IP-10 Main enclosure in the 19 inch rack using 4 screws. Step #2: Slide down the 2nd extension enclosure. Male connector should plug in smoothly into the Main enclosure. Step #3: Slide down the 2nd extension enclosure. Male connector should be plugged in smoothly into the Main enclosure.

11

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Step #4: Secure the 2nd extension into the Main enclosure. Use the built-in screw. Mount the 2nd extension into the rack using the 4 screws

12

Proprietary and Confidential

Installing Nodal Enclosures in a 19 Rack


Step #4: Secure the 2nd extension into the Main enclosure. Use the built-in screw. Mount the 2nd extension into the rack using the 4 screws Step #5: Add the 3rd extension when needed

13

Proprietary and Confidential

Preparing the IDU for a Shelf installation


Remove the two 19" brackets mounted on the IP-10 IDU by unscrewing the 3 screws at each side.

14

Proprietary and Confidential

Installing the IDU in a Shelf


Slide the IP-10 IDU into the enclosure and tighten it using 2 screws. Repeat this step in accordance with the configuration.

IDU insertion & extraction should NOT be under power

15

Proprietary and Confidential

Installing a Blank Panel IDU in a Shelf


Slide the IP-10 blank panel into the enclosure, and tighten it using 2 screws.

16

Proprietary and Confidential

Installing a T-Card into an IDU


Remove the IP-10 T-Card blank panel from the IDU, by releasing the 2 side screws.

17

Proprietary and Confidential

Installing a T-Card into an IDU


Insert the IP-10 T-Card panel and tighten it using the 2 side screws.

18

Proprietary and Confidential

Grounding the IDU

Single Point Stud Grounding Wire

19

Proprietary and Confidential

Grounding the IDU


The IDU is suitable for installation in a Common Bonding Network (CBN).

Only copper wire should be used.


The wire must be at least 14 AWG. Connector and connection surfaces must be plated. Bare conductors must be coated with antioxidant before crimp connections are made to the screws. FibeAir provides a ground for each IDU, via a one-hole mounted lug onto a single-point stud. The stud must be installed using a UL-listed ring tongue terminal, and two star washers for anti-rotation.

20

Proprietary and Confidential

Power General Requirements


1. A readily accessible Listed branch circuit over-current protective device, rated 15 A, must be incorporated in the building wiring.

2. This equipment is designed to permit connection between the earthed conductor of the DC supply circuit and the earthing conductor at the equipment.
3. The equipment shall be connected to a properly grounded supply system 4. The DC supply system is to be local, i.e. within the same premises as the equipment 5. A disconnect device is not allowed in the grounded circuit between the DC supply source and the frame/grounded circuit connection.

21

Proprietary and Confidential

Power Requirements
When selecting a power source, the following must be considered:

DC power can be from -40.5 VDC to -60 VDC.


Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency power generator.

Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut off frequently and consistently).
The power supply must have grounding points on the AC and DC sides. The user power supply GND must be connected to the positive pole in the IDU power supply. Any other connection may cause damage to the system!

22

Proprietary and Confidential

Power Requirements
Important Make sure to use a circuit breaker to protect the circuit from damage by short or overload.

23

Proprietary and Confidential

Installing the IDU-ODU IF cable


Route the IF Coax Cable from the IDU to the ODU/RFU and terminate it with N-type male connectors. Note: Make sure you fasten the cable along the ladder! Make sure that the inner pin of the connector does not exceed the edge of the connector. The cable should have a maximum attenuation of 30 dB at 350 MHz.

24

Proprietary and Confidential

Logging in, assigning IP address


CLI access groups:

Viewer Operator Admin Tech

read-only access read-write access but cannot add/remove other users read-write access including add/remove other users read-write access including add/remove other users as well as access to a bridge-specific CLI shell

Currently only Admin is defined Other groups or users can be created via CLI only

Proprietary and Confidential