Vous êtes sur la page 1sur 2

Tight-buffered universal-cable indoor/outdoor with multi-mode fibers G50/125 Infinicor 600

Outer jacket, FRNC nom. 0,8 mm Tight buffer TB3, Diameter 0.9 0,05 mm Strength members (Aramid) with swellable element Ripcord

Principle Drawing

A-VH 12x1 G50/125 2,7B500 + 0.8F500 TB3 FRNC

Design and special properties Cabling for assemblers is designed with 900 m tight buffer for direct assembly with single fiber connectors Low smoke to IEC 61034 and zero-halogen (LSOH) Flame retardant to IEC 60332-3 and non corrosive to IEC 60754-2 (FRNC) and DIN VDE 0472 part 813 Water blocking to IEC 60794-1-F5 (completely dry design) Metal-free, hence no ground loop problems Tight-buffer design 900 m (TB3) easy to strip

Archive: CCS AE Datasheet: 04-10-27 A-VH 12x1 G50 e PA 048841

CCS reserves the right to improve, enhance, and modify the features and specifications of CCSs products without prior notification. The information in this data sheet has been reproduced in good faith and is accurate, to the best of CCSs knowledge, at the time of printing. However, CCS makes no warranty as to, and will not be liably on any basis for, the information contained within this data sheet.

1/2

Coloring Fiber: Tight buffer: Outer jacket: Cable printing: nature blue, orange, green, brown, grey, white, red, black, yellow, violet, rose, turquoise black acc. Customer request

Optical Characteristics of fibers G50L/125 InfiniCor 600 OM2: Typical attenuation at 850 nm Typical attenuation at 1300 nm Maximum attenuation at 850 nm Maximum attenuation at 1300 nm Bandwidth-length product (OFL=Over field Launch) for 1 km at 850 nm Bandwidth-length product (OFL=Over field Launch) for 1 km at 1300 nm Laser Bandwidth-length product (RML=Restricted mode launch) for 1 km at 850 nm Guaranteed minimum distances for Gigabit Ethernet at 850 nm Guaranteed minimum distances for Gigabit Ethernet at 1300 nm Guaranteed minimum distances for 10 Gigabit Ethernet at 850 nm Fiber data are available upon request (fiber datasheet Technical cable characteristics Mechanical and environmental: Number of fibers Diameter tight buffer [mm] Outer diameter, approx. [mm] Weight of the cable, approx. [kg/km] Max. tensile load during installation [N] Compressive stress/crush (attenuation increase reversible) [N/10 cm] Min. bending radius during installation [mm] Min. bending radius in operation [mm] Temperature range Laying and installation [C] Operation Transport and storage 12 0.900,05 6,2 37 800 2000 95 70 -5 to 50 -20 to 60 -25 to 70 [dB/km] [dB/km] [dB/km] [dB/km] [MHz x km] [MHz x km] [MHz x km] m m m 2.7 0.8 3.5 1.5 500 500 510 600 600 82

Delivery length Standarf delivery length 4000m , Other options are available on request.

Archive: CCS AE Datasheet: 04-10-27 A-VH 12x1 G50 e PA 048841

CCS reserves the right to improve, enhance, and modify the features and specifications of CCSs products without prior notification. The information in this data sheet has been reproduced in good faith and is accurate, to the best of CCSs knowledge, at the time of printing. However, CCS makes no warranty as to, and will not be liably on any basis for, the information contained within this data sheet.