Vous êtes sur la page 1sur 5

CQI mapping table for UE categories 1 to 6

CQI value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Transport Block Number of


Size
HS-PDSCH
N/A
137
173
233
317
377
461
650
792
931
1262
1483
1742
2279
2583
3319
3565
4189
4664
5287
5887
6554
7168
7168
7168
7168
7168
7168
7168
7168
7168

1
1
1
1
1
1
2
2
2
3
3
3
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Modulation

QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM

Reference power
adjustment
Out of range
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-1
-2
-3
-4
-5
-6
-7
-8

NIR

XRV

9600

CQI mapping table for UE categories 7 and 8


CQI value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Transport Block Number of


Size
HS-PDSCH
N/A
137
173
233
317
377
461
650
792
931
1262
1483
1742
2279
2583
3319
3565
4189
4664
5287
5887
6554
7168
9719
11418
14411
14411
14411
14411
14411
14411

1
1
1
1
1
1
2
2
2
3
3
3
4
4
5
5
5
5
5
5
5
5
7
8
10
10
10
10
10
10

Modulation

QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM

Reference power
adjustment
Out of range
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-1
-2
-3
-4
-5

NIR

XRV

19200

CQI mapping table for UE category 9


CQI value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Transport Block Number of


Size
HS-PDSCH
N/A
137
173
233
317
377
461
650
792
931
1262
1483
1742
2279
2583
3319
3565
4189
4664
5287
5887
6554
7168
9719
11418
14411
17300
17300
17300
17300
17300

1
1
1
1
1
1
2
2
2
3
3
3
4
4
5
5
5
5
5
5
5
5
7
8
10
12
12
12
12
12

Modulation

QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM

Reference power
adjustment
Out of range
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-1
-2
-3
-4

NIR

XRV

28800

CQI mapping table for UE category 10


CQI value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Transport Block Number of


Size
HS-PDSCH
N/A
137
173
233
317
377
461
650
792
931
1262
1483
1742
2279
2583
3319
3565
4189
4664
5287
5887
6554
7168
9719
11418
14411
17300
21754
23370
24222
25558

1
1
1
1
1
1
2
2
2
3
3
3
4
4
5
5
5
5
5
5
5
5
7
8
10
12
15
15
15
15

Modulation

QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM
16-QAM

Reference power
adjustment
Out of range
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0

NIR

XRV

28800

CQI mapping table for UE categories 11 and 12


CQI value
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Transport Block Number of


Size
HS-PDSCH
N/A
137
173
233
317
377
461
650
792
931
1262
1483
1742
2279
2583
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319
3319

1
1
1
1
1
1
2
2
2
3
3
3
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Modulation

QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK
QPSK

Reference power
adjustment
Out of range
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-1
-2
-3
-4
-5
-6
-7
-8
-9
-10
-11
-12
-13
-14
-15

NIR

XRV

4800

Vous aimerez peut-être aussi